S pecmate Center Spine Cable Tray is an easily installed

Size: px
Start display at page:

Download "S pecmate Center Spine Cable Tray is an easily installed"

Transcription

1 SpecMate Cable Tray Systems Center Spine Cable Tray A/SRA Series S pecmate Center Spine Cable Tray is an easily installed cable support system designed with many unique features to provide safety, reliability and flexibility for future expansion. Removable, replaceable and interchangeable rungs, unique pivot connectors and field modifiable fittings combine to allow installers to easily maneuver around unforeseen obstructions and sudden changes in elevation. In order to reduce installation time, each tray also comes with preassembled couplings. Never before has hanging cable tray been so easy! SpecMate Center Spine Cable Tray can be used to construct a complete cable tray system with controlled 2" [51mm] nominal bend radius that meets the specifications for fiber optic and UTP/STP cabling and exceeds TIA 569 requirements for communications pathways. Designed for use in retrofit, new or existing applications. Specify SpecMate Cable Tray and fittings, available only from Wiremold. Complete System, including Fittings 1" [25mm] wide rungs, unique to Wiremold, provide the widest cable laying surface available. These removable, replaceable and interchangeable rungs allow for easy field modification, future expansion and true cable management. Complete system, including 2" [51mm] Fiber Optic radiused fittings. Install a complete Cable Tray System, through the use of SpecMate Field and Flo-Thru Tees, Crosses, Horizontal and Vertical Pivot s. These fittings provide a 2" [51mm] cable bend radius and exceed the recommendations of TIA/EIA 568-A. WIREMOLD EXCLUSIVE FEATURE! Removable, replaceable and interchangeable rungs provide flexibility. Unique screw-in rungs can be removed and replaced with longer rungs for future expansion or modification without removing the cables, allowing for true cable management. Rungs can also easily be removed in the field to avoid obstacles. WIREMOLD EXCLUSIVE FEATURE! Standard 1" [25mm] wide rungs provide the widest cable laying surface available. Provides support surface for fiber optic and communication cabling which can be damaged by cold flow cable insulation degradation under load. When this is not a concern, 5/8" [16mm] wide SRA Series rungs are available. WIREMOLD EXCLUSIVE FEATURE! Extruded rungs provide direct connection for accessories. 1" [25mm] A Series rungs are extruded with internal screw threads to accept rung mounted accessories like conduit adaptors and cable dropouts. WIREMOLD EXCLUSIVE FEATURE! Preassembled splice connector. A splice connector is provided, preassembled to the tray, to facilitate installation. WIREMOLD EXCLUSIVE FEATURE! Features & Benefits Center lines are provided as drilling guides. All spines and fittings are designed with center alignment marks to make adding screw holes easy in the field. Rungs are factory fitted with protective plastic caps. All rungs are capped to prevent damage to cables and injury to the installer. WIREMOLD EXCLUSIVE FEATURE! Tray, rungs and fittings are available factory painted in a wide variety of colors and textures. Can be used to enhance the aesthetics of any installation or allow for visual differentiation between cable runs. 3" [76mm] center spine serves as a barrier between services. The 3" [76mm] spine serves as a barrier separating one channel of the tray from the other when used with 3" [76mm] rungs. Spine extenders are available for use with 4" and 6" [102mm and 152mm] rungs as well as dividers to provide barriers within each channel. Center Spine Cable Tray: Installs in half the time of conventional ladder tray. Can be loaded from sides of tray in most cases. Uses half the hanging and joining material of conventional ladder tray. Allows for full cable visibility and requires less space for access. Can be hung as close to ceiling as code allows. Custom lengths, widths, heights are easily accommodated. For configurations not shown please consult the factory. ED691R3 Updated August 2005 For latest specs visit

2 SpecMate Center Spine Cable Tray System Layout 90 Horizontal Elbow Stiffener Bar Vertical Pivot Tray to Box Cable Dropout Blind End Hanger Bracket Divider Strip Flo-Thru Cross Splice Center Spine Cable Tray All rungs are factory fitted with protective caps. A Series Tray installed in raised floor application. Rungs extruded with internal screw threads provide direct connection for mounting accessories. 2

3 SpecMate A Series Center Spine Cable Tray System Layout with Fittings 90 Horizontal Elbow Stiffener Bar Tray to Box Vertical Pivot Field Tee Rung Adaptor Hanger Bracket Horizontal Pivot Divider Strip Cable Dropout Splice Conduit Flo-Thru Cross Center Spine Cable Tray Blind End Cable Drop Out Fitting on 12" [305mm] A Series tray, shown to the left, maintains radius even under heavy load. Innovative Spine and screw-in removable, replaceable and interchangeable rungs offer unparalleled cable management options. ATR/SATR Series top rung configuration offers a single channel. Available up to 18" [457mm] wide. 3

4 SpecMate Center Spine Cable Tray Fittings Item* Catalog No. Description Specifications Height Width RB(height)(width) SRB(height)(width) 1" [25mm] wide Replacement Rungs 5/8" [16mm] wide Replacement Rungs Available Heights Available Widths 3" [76mm] 3" [76mm] 4" [102mm] 4 1/2" [114mm] 6" [152mm] 6" [152mm] 9" [229mm] 12" [305mm] 15" [381mm] 18" [457mm] Field removable, replaceable and interchangeable rungs provide flexibility for future expansion or modification without removing the cables, thus allowing for true cable management. All rungs are factory fitted with protective plastic caps. 0100ASCO Splice Allows the connection of any two pieces of A, B, C, D, and DD Series Tray. Hole in center accepts 1/2" [12.7mm] threaded rod for hanging. 0100ASSC Split Splice Allows the connection of any two pieces of A and B Series Tray after the center rod has been hung. Generally used to add a second tier of tray to an existing installation. 0200AHPC Horizontal Pivot Allows any angle horizontal connection for all A, C, D, and DD Series Tray. For 90 or wider angles, the use of a Horizontal Pivot with Rung is recommended. 0200AHPR(height)(width) Horizontal Pivot with Rung Provides additional cable support on horizontal connections for all A, C, D, and DD Series Tray. Can be used for any angle horizontal connection. 0200AHPRFO(height)(width) 2" [51mm] Radius Horizontal Pivot with Rung Provides a 2" [51mm] radius, allows any angle horizontal connection and provides additional cable support on horizontal turns for all A and SRA Series trays. 22(bend radius)ahe90(width) Custom 90 Horizontal Elbow Allows for 90 horizontal turns with radii of 12" [305mm] or more. Made with two Horizontal Pivots and one section of tray with 6" [152mm] rung spacing. Used for larger radius requirements. 4

5 SpecMate Center Spine Cable Tray Fittings Item* Catalog No. Description Specifications 0200AVPC Vertical Pivot Allows for vertical bends for all A, SRA and B Series trays. 0200AVPCFO(width) 2" [51mm] Radius Vertical Pivot Provides a 2" [51mm] radius and allows for vertical bends for all A and SRA Series trays. ATRAYRA(height) 2" [51mm] Radius Rung Adaptor Slips onto any A or SRA Series rung and provides a 2" [51mm] radius on either side for cable dropout protection or tee or cross transition. AFT(width)(rung spacing) SRAFT(width)(rung spacing) Field Tee Field Tee Used to make a tee (or Y turn) in the field for trays with 6", 9", 12" or 18" [152mm, 229mm, 305mm, or 457mm] rung spacing. Same as above with 5/8" [16mm] wide SRA rungs. NOTE: A Field Cross may be formed by using two Field Tees. At each tee connection, a 1/2" [13mm] threaded rod should be utilized. AFTFO(width)(height)(rung spacing) SRAFTFO(width)(height)(rung spacing) 2" [51mm] Radius Field Tee 2" [51mm] Radius Field Tee Provides a 2" [51mm] cable bend radius on a tee (or Y turn) made in the field. For trays with 6", 9", 12" or 18" [152mm, 229mm, 305mm, or 457mm] rung spacing. Same as above with 5/8" [16mm] wide rungs. NOTE: A Field Cross may be formed by using two Field Tees. At each tee connection, a 1/2" [13mm] threaded rod should be utilized for support. AMT(height)(main run width)(tee run width)(fitting radius)* Flo-Thru Tee Tee (or Y turn) with no barrier between channels. * See Fitting Radius Determination page 10. 5

6 SpecMate Center Spine Cable Tray Fittings Item* Catalog No. Description Specifications AMTFO(height)(main run width)(tee run width)(fitting radius)* 2" [51mm] Radius Flo-Thru Tee Provides a 2" [51mm] cable bend radius on a tee (or Y turn) with no barrier between channels. AMX(height)(main run width)(cross run width)(fitting radius)* Flo-Thru Cross Tee, cross or Y turn with no barrier between channels. AMXFO(height)(main run width)(cross run width)(fitting radius)* 2" [51mm] Radius Flo-Thru Cross Provides a 2" [51mm] cable bend radius on a tee cross or Y turn with no barrier between channels. 07(rung spacing)ccp(size of conduit) Custom Conduit Connects conduit to tray. Consult factory to order. Mounting Height Rung Height JH(rung height)(lay-in width)(mounting height) J Rung A single rung, bent in the shape of a J, supports cables on walls. Width GH(rung height)(lay-in width)(mounting height) G Rung A single rung, bent in the shape of a G. Supports cables overhead and on walls. Mounting Height Rung Height Width * See Fitting Radius Determination page 10. 6

7 SpecMate Center Spine Cable Tray Fittings Item* Catalog No. Description Specifications 06(width)ACDO Fiber Ready Cable Dropout Extruded aluminum fitting provides a 2" [51mm] cable bend radius for cables dropping out of all A, SRA and B Series trays. NOTE: (Width) should equal total size of tray. Example: 0612ACDO will provide one 6" [152mm] dropout. 0504ASBR Hanger Bracket Provides support for the tray at any point other than at the splice connector without drilling. May also be used to develop seismic restraint consult factory. Hole is pre-punched to accept 1/2" [12.7mm] threaded rod. 05(width)ABE(height) Blind End Closes off the end of the tray. 05(width)ATBC(height) Tray to Box Provides a frame for cables entering the tray from or through the wall. 0501ATWC Tray to Wall /End Cap Connects tray to wall. Also acts as an end cap to close off end of center spine. 7

8 SpecMate Center Spine Cable Tray Fittings Item* Catalog No. Description Specifications 09(height)AFSB Floor Support Bracket Provides support for trays used in raised floor applications. Specify height from floor (to bottom of tray) required. 09(maximum height)astb Stiffener Bar Maximum Minimum Height Height 18" [457mm] 10" [254mm] 24" [610mm] 16" [406mm] 30" [762mm] 22" [559mm] 36" [914mm] 28" [711mm] 42" [1.07m] 34" [864mm] 48" [1.22m] 40" [1.02m] 54" [1.37m] 46" [1.17m] 60" [1.52m] 52" [1.32m] Provides additional support to offset eccentric loading. Furnished unpainted in aluminum 1/4" x 2" [6mm x 51mm]. Specify length required. The stiffener bar is designed to allow approximately 8" [203mm] of tolerance as indicated in the chart on the left. 0803ADVS 0804ADVS 0806ADVS 3" [76mm] Divider Strip 4" [102mm] Divider Strip 6" [152mm] Divider Strip Provides a barrier for 3" [76mm] high trays. Provides a barrier for 4" [102mm] high trays. Provides a barrier for 6" [152mm] high trays. All divider strips come in 12' [3.66m] sections. 0801ASPX 1" [25mm] Spine Extension Provides a 1" [25mm] height extension for a 12' [3.66m] length of A Series tray. (Extends the spine to 4" [102mm] to match 4" [102mm] high rungs.) 0803ASPX 3" [76mm] Spine Extension Provides a 3" [76mm] extension for a 12' [3.66m] length of A Series tray. (Extend the spine to 6" [152mm] to match 6" [152mm] high rungs.) 8

9 SpecMate Center Spine Cable Tray Product Selection Guide End View Side View (section) 5/8" 1" [15.9mm] 13/16" [25mm] [21mm] 1/2 Tray Width 1/2 Tray Width Tray Depth Rung Spacing 1" [25mm] 5/8" [15.9mm] CATALOG NUMBERING LOGIC Series: Tray Depth*: Rung Spacing: Overall Tray Width: SERIES LENGTH RUNGS A 12' [3.6m] 1" [25mm] CA 10' [3.0m] 1" [25mm] SRA 12' [3.6m] 5/8" [15.9mm] CSRA 10' [3.0m] 5/8" [15.9mm] ATR 12' [3.6m] 1" [25mm] CATR 10' [3.0m] 1" [25mm] SATR 12' [3.6m] 5/8" [15.9mm] CSATR 10" [3.0m] 5/8" [15.9mm] 03 3" [76mm] 04 4" [102mm] 06 6" [152mm] 06 6" [152mm] 09 9" [229mm] 12 12" [305mm] 18 18" [457mm] 06 6" [152mm] 09 9" [229mm] 12 12" [305mm] 18 18" [457mm] 24 24" [610mm] 30 30" [762mm] 36 36" [914mm] NOTE: Measured at inside of rungs as shown above. EXAMPLE CATALOG NUMBER To order one 12' [3.66m] length of standard Center Spine Cable Tray, 3" [76mm] deep, 12" [305mm] rung spacing and 18" [457mm] wide with 1" [25mm] rungs, use catalog number: A Series: Tray Depth*: Rung Spacing: Overall Tray Width: NOTE: Each section of tray is shipped with one splice connector and necessary hardware. * The height of the center spine is 3" [76mm]. If the spine is being used as a divider, a spine extender is needed to maintain full separation between channels on 4" [102mm] and 6" [152mm] deep tray. For 4" [102mm] deep tray use 0801ASPX. For 6" [152mm] deep tray, use 0803ASPX. ** When ordering a tray 18" [457mm] in width or larger the use of a stiffener bar should be considered to stabilize eccentric loading. Measured at inside of rungs. Custom Options for A and SRA Series Trays Item Description Specifications Cover Screw Down Tray covers are formed with a 1/2" [13mm] lip down the outside of the rung crossing over the entire tray and have another 1/2" [13mm] lip formed over the outside of the other rungs. Cover Hinged Hinged covers are also available. Covers can be provided with a full piano hinge for mounting to the spine of the tray in the field. NOTE: Inside tray liners and decorative outside tray enclosures are also available for full lengths of cable tray only. For an aesthetic finish, tray enclosures may be painted to complement existing decor. Consult factory for details. 9

10 SpecMate Center Spine Cable Tray Systems Technical Data NEMA LOAD/SPAN DESIGNATIONS NEMA Class Support Span Working Load* 12A 12 ft. 50 lb./ft. 12B 12 ft. 75 lb./ft. 12C 12 ft. 100 lb./ft. * The working load is the total weight of all cables and tubing to be placed in the tray. CSA LOAD CLASS CAPACITIES AT VARYING SUPPORT SPACINGS Support Spacing 1.5m 2.0m 2.5m 3.0 CSA Class Working Load* A 99kg/m 62kg/m 45kg/m 37kg/m C1 259kg/m 164kg/m 119kg/m 97kg/m D1 N/A N/A N/A 179kg/m E N/A N/A N/A 299kg/m When designing, specifying or installing a cable tray system, please consider the following (from the Canadian Electrical Code, Appendix B ): a. Allowance for wind and snow loading should be included within the maximum design load. b. Some fittings (particularly horizontal elbows) may require additional support depending on the loading. Per NEMA Standard Publication VE-1, Cable Tray is designed as a support for power or control cables, or both, and is not intended or designed to be a walkway for personnel. The user is urged to display appropriate warnings against the use of this support as a walkway. Each section of tray has a warning label. SpecMate NEMA Load Ratings A, SRA Series Tray (12' [3.66mm] lengths) Tray Rung Tray NEMA Depth Spacing Width Rating 3" [76mm], 4" [102mm] 6" [152mm], 9" [229mm], 18" [457mm], 24" [610mm], 12B 6" [152mm] 12" [305mm], 18" [457mm] 30" [762mm], 36"[914mm] 3" [76mm], 4" [102mm] 18" [457mm] 12" [305mm] 12B 6" [152mm] 3" [76mm], 4" [102mm] 6" [152mm], 9" [229mm], 6" [152mm], 9" [229mm] 12C 6" [152mm] 12" [305mm], 18" [457mm] 3" [76mm], 4" [102mm] 6" [152mm], 9" [229mm], 12" [305mm] 12C 6" [152mm] 12" [305mm] NOTE: All SpecMate ATR and SATR trays are NEMA 12B rated. All SpecMate CATR and CSATR tray is CSA C1 rated. All ratings represent a 1.5 x safety factor. Standard Material Cable Tray Spine, Rungs and Fittings: 6063T6 Aluminum Alloy Liners and Covers: 5052 Aluminum Alloy Member of: SpecMate CSA Load Ratings CA Series Tray (10' [3m] lengths) Tray Rung Tray CSA Depth Spacing Width Rating 3" [76mm], 4" [102mm] 6" [152mm], 9" [229mm], 24" [610mm], C1 6" [152mm] 12" [305mm], 18" [457mm] 30" [762mm], 36"[914mm] 3" [76mm], 4" [102mm] 6" [152mm], 9" [229mm], 6" [152mm], 9" [229mm], D1 6" [152mm] 12" [305mm], 18" [457mm] 12" [305mm], 18" [457mm] SpecMate CSA Load Ratings CSRA Series Tray (10' [3m] lengths) Tray Rung Tray CSA Depth Spacing Width Rating 3" [76mm], 4" [102mm] 6" [152mm], 9" [229mm], 6" [152mm], 9"[229mm], C1 6" [152mm] 12" [305mm], 18" [457mm] 12" [305mm], 18" [457mm], 24" [610mm], 30" [762mm], 36" [914mm] d u c Third Party Certifications UL File No. E CSA File No Fitting Radius Determination Several Cable Tray fittings require that a fitting radius be specified upon ordering. It is not necessary that this fitting radius match the width of the cable tray being used. Rather, the fitting radius must be sized to accommodate the bend radius and stiffness of the cables that will be run in the system and must be equal to or greater than the cable manufacturer s recommended minimum bend radius for the largest cable anticipated to be installed in the cable tray. When several cables are to be installed in the same cable tray run, consider a larger fitting radius to ease cable installation. Consult the cable manufacturer for their recommended minimum bend radius for each individual cable. PLEASE NOTE: The overall physical dimensions of a Cable Tray Fitting increase dramatically as the specified fitting radius of a cable tray fitting increases. This factor, as well as cost, makes the selection of the smallest acceptable fitting radius the most desirable. When larger radius fittings are required, the entire cable tray system layout must be designed to allow adequate space. Please consult the factory for further details. Fitting Radius 10

11 Center Spine Cable Tray Wire Fill Capacity CABLE/ CATEGORY/ O.D. NUMBER OF WIRES (Height x Width) WIRE TYPE WIRE SIZE Inches [mm] 3 x 6 3 x 9 3 x 12 3 x 18 3 x 24 3 x 30 3 x 36 4 x 6 4 x 9 4 x 12 UNSHIELDED Cat 3, 4-pair, 24 AWG [4.8] TWISTED PAIR Cat 5, 4-pair, 24 AWG [5.6] Cat 5e, 4-pair, 24 AWG [6.3] Cat 6, 4-pair, 24 AWG [6.3] SHIELDED Type [9.6] TWISTED PAIR Type [11.8] Type [6.9] TELEPHONE 2-Pair 24 AWG [3.5] Pair, 24AWG [3.8] Pair, 24 AWG [4.8] Pair, 24 AWG [ COAXIAL RG58/U [4.7] RG59/U [6.1] RG62/U [6.1] RG6/U [6.8] TWINAXIAL 100 Ohm [8.4] FIBER OPTIC Duplex Multimode [4.8] Center Spine Cable Tray Wire Fill Capacity (continued) CABLE/ CATEGORY/ NUMBER OF WIRES (Height x Width) WIRE TYPE WIRE SIZE 4 x 18 4 x 24 4 x 30 4 x 36 6 x 6 6 x 9 6 x 12 6 x 18 6 x 24 6 x 30 6 x 36 UNSHIELDED Cat 3, 4-pair, 24 AWG TWISTED PAIR Cat 5, 4-pair, 24 AWG Cat 5e, 4-pair, 24 AWG Cat 6, 4-pair, 24 AWG SHIELDED Type TWISTED PAIR Type Type TELEPHONE 2-Pair 24 AWG Pair, 24AWG Pair, 24 AWG Pair, 24 AWG COAXIAL RG58/U RG59/U RG62/U RG6/U TWINAXIAL 100 Ohm FIBER OPTIC Duplex Multimode NOTE: Values are based on fill capacity only cable weights must also be checked to ensure that load capacity of the tray is not exceeded. Fill values are based on NEC fill requirement stating a maximum allowable fill of 50% of tray cross sectional area. In reality, this is a fully loaded tray due to spaces between cables. 11

12 2" Radius Fittings Vertical Pivot. Horizontal Pivot with Rung. Field Cross Fitting (consists of two field tees). Wiremold / Legrand U.S. and International: 60 Woodlawn Street West Hartford, CT FAX Outside U.S Canada: 570 Applewood Crescent Vaughan, Ontario L4K 4B FAX Copyright 2005 Wiremold / Legrand All Rights Reserved ED691R3 Updated August 2005 For latest specs visit

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but

More information

Dropping power and communications neatly and simply from up

Dropping power and communications neatly and simply from up Bring Wiring Down to Business Dropping power and communications neatly and simply from up there to down here: that s what Wiremold Tele-Power Poles are all about. Their sole purpose is to get the business

More information

ONTRAC WIRE MESH CABLE TRAY SYSTEM

ONTRAC WIRE MESH CABLE TRAY SYSTEM P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network

More information

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.

More information

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough

T&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All

More information

CT-02 CABLE TRAY SYSTEMS

CT-02 CABLE TRAY SYSTEMS CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry

More information

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute

More information

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia

Cable ladder installation at S.C.M. Chemicals Limited s titanium dioxide Plant in Western Australia Exel Composites Cable Support Systems offer engineers a structural product for solving many design and plant engineering problems, enabling long term reliable support of expensive and often critical cables.

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

Power Commander Power Distribution Units from Wiremold/Legrand offer

Power Commander Power Distribution Units from Wiremold/Legrand offer Power Commander Power Distribution Units Rack Power Distribution Solutions for IT/Network Environments Power Commander Power Distribution Units from Wiremold/Legrand offer comprehensive power distribution

More information

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL

More information

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery Alpha System ADAPTABLE LABORATORY FURNITURE KEWAUNEE encouraging new discovery Alpha 6 partition modules with Kemresin worktops. Minneapolis, Minnesota Alpha 6 partition modules with Alpha overhead service

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

Meeting Room Solutions

Meeting Room Solutions Meeting Room Solutions Work Surface Modular Power Reconfigurable power solutions optimize meeting spaces Wiremold Work Surface Modular Power kits make rearranging meeting rooms fast, easy, and safe. Today

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

Bring power safely and conveniently to wherever

Bring power safely and conveniently to wherever Plug-In Outlet Center Units Plug-In Outlet Center Units Bring power safely and conveniently to wherever you need it with a full line of Plug-In Outlet Center Units from Wiremold/Legrand. These units are

More information

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series en Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager Table of Contents en 3 Table of Contents 1 Planning 4 1.1 Hardware Requirements 4 1.2 Pre-installation

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

FiberGuide Fiber Management Systems. 4th Edition

FiberGuide Fiber Management Systems. 4th Edition FiberGuide Fiber Management Systems 4th Edition Table of Contents Introduction Introduction...1 A Variety of Solutions...2 Innovative Products...3 Features and Benefits... 4 Applications Combining System

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Chapter 10 - Scaffolding Systems

Chapter 10 - Scaffolding Systems Chapter 10 - Scaffolding Systems Contents Chapter 10 - Scaffolding Systems... 10-1 Check and Oil the Pump Jacks... 10-4 Set Pump Jack Brackets... Error! Bookmark not defined. Set Pump Jack Poles... 10-5

More information

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your

More information

CABLE SUPPORT SYSTEMS

CABLE SUPPORT SYSTEMS CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder

More information

SECTION 4: Cable Ladder Stainless Steel & Aluminium

SECTION 4: Cable Ladder Stainless Steel & Aluminium SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General

More information

Cable Tray Selection-

Cable Tray Selection- Cable Selection- For allowable cable types see the Appendix page A-9. The following guidelines are based on the 2002 National Electrical Code, Article 392. I) Number of Multiconductor Cables rated 2000

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

AC and DC Drive System Installation Information

AC and DC Drive System Installation Information Purpose This document contains the Parker SSD Drives recommendations for installing drive systems. These instructions must be followed for safe and reliable operation. Instructions CODES AND REGULATIONS

More information

DELTA3-1. Delta 3 Data Centre Rack Solution

DELTA3-1. Delta 3 Data Centre Rack Solution DELTA3-1 Delta 3 Data Centre Rack Solution Contents Building on more than 50 years of British design and innovation, Cooper B-Line introduces Delta 3 ( Delta cubed ). Designed to offer M.O.R.E. to customers

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

Flextray - Installation. Installation

Flextray - Installation. Installation 50 Flextray Cutters Part Qty./Box Wt./Box Number lbs. kg CLEANSHEAR Cleanshear 1 4.3 1.95 Cutting Tool Exclusive, patented Cleanshear cuts tray fast No sharp edges Designed specifically for cutting Flextray

More information

Architect/Contractor Information Package

Architect/Contractor Information Package Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold

ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold Rack Power Distribution Solutions for IT/Network Environments Wiremold Power Commander Power Distribution Units offer comprehensive power distribution solutions for IT environments from networking solutions

More information

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372

PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372 PRO PANELS by MD Enterprises the artist s choice in display designed by artists, for artists 1-800-525-4159 www.propanels.com voice: 214-350-5765 fax: 214-350-7372 MD Enterprises 1-800-525-4159 voice:

More information

Intelligent Cable Management Systems

Intelligent Cable Management Systems Intelligent Cable Management Systems Bringing Practical Application Karen Pearson - Leviton Why Cable Management Matters Performance Cooling and air-handling Maintenance ANSI/TIA 569* Telecommunication

More information

GUE, GUB Junction Boxes

GUE, GUB Junction Boxes E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049 Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal

More information

HOW TO MEASURE FOR DRAPERY & WINDOW

HOW TO MEASURE FOR DRAPERY & WINDOW HOW TO MEASURE FOR DRAPERY & WINDOW From the fabric you select to the hardware that you choose, window treatments are an opportunity to define a room s style. This guide outlines the various drapery styles

More information

9300BC SERIES Light Commercial Door Closer

9300BC SERIES Light Commercial Door Closer Light Commercial Door Closer general information The 9300BC is a durable, economically priced door closer designed for commercial exterior and interior doors such as storefront and industrial applications.

More information

270526-TC Grounding and Bonding for Telecommunications Systems

270526-TC Grounding and Bonding for Telecommunications Systems 270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer

More information

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

1. Lay out 2 pieces of 7/8 tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1. MINI BIKE PLANS Page 1 INTRODUCTION Before starting to build your Mini-Bike, be sure that you have all the parts shown on the material list. You will note that tubing has been used in the construction.

More information

I BEAM TRACK INSTALLATION

I BEAM TRACK INSTALLATION PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must

More information

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship

More information

BUILDINGA 1/10 SCALE FLATBED TRAILER

BUILDINGA 1/10 SCALE FLATBED TRAILER VOLUME 1, ISSUE 1 BUILDINGA 1/10 SCALE FLATBED TRAILER BUILT, DESIGNED & WRITTEN BY NATHAN MYERS MATERIALS: FEATURES: While the design was kept simple to allow anyone to be able to build their own trailer,

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

2301.1 Scope: Communications and Electronic Systems addressed in this section include:

2301.1 Scope: Communications and Electronic Systems addressed in this section include: Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and

More information

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Andersen Electric Window Opener for Andersen Awning and Roof Windows W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of

More information

screens U N D E R S TA N D I N G S C R E E N S...9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...9 3

screens U N D E R S TA N D I N G S C R E E N S...9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...9 3 U N D E R S TA N D I N G S C R E E N S...........................9 0 PA N E L WA L L A D D - O N S C R E E N B A S I C S...................9 3 P L A N N I N G W I T H A D D - O N S C R E E N S.....................9

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER

METHOD STATEMENT FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER Page 1 of 6 FOR INSTALLATION OF CABLE TRAY/TRUNKING/LADDER 0 Issued for Review & Comments Rev. Date Description Eng. A.H Prepared by Checked by Approved by Page 2 of 6 REVISION CONTROL SHEET REV. NO. DATE

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

ECM-D70T / ECM-D70T1.5

ECM-D70T / ECM-D70T1.5 Elliptical Ceiling Dual Mount for 37 to 50 Flat Panels INSTALLATION INSTRUCTIONS CREATING POSITIVE CUSTOMER EXPERIENCES 9531-041-001-01 Contents ECM-D70T / ECM-D70T1.5 Installation Tools... 3 Parts List...

More information

Wisconsin Building Products Evaluation

Wisconsin Building Products Evaluation Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation

More information

Copper Meter Resetters

Copper Meter Resetters Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12 Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs. FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds

More information

DATA CENTER SOLUTIONS GUIDE

DATA CENTER SOLUTIONS GUIDE DATA CENTER SOLUTIONS GUIDE designed to be better. Power Cabinets Racks Pathways Aisle Containment Connectivity and Cabling RACKS AND CABINETS Legrand s cabinets and racks, designed for all your network

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors The Quality Connection High Performance Cable Solutions for the World of Semiconductors 2 Total Flexibility for Applications with the Toughest Requirements LEONI is your long-term, reliable partner supplying

More information

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames. SPECIFICATION Allowed anodization before fabrication for clear frames. Page 2 of 9 1. SCOPE 1.1. This document provides general requirements for aluminum frames used in the assembly of photovoltaic modules.

More information

Casement/Awning Window Parts Reference Catalog

Casement/Awning Window Parts Reference Catalog Casement/Awning Window Parts Reference Catalog (Includes Miscellaneous Parts for Eyebrow Casement and Garden Bay Windows) #1028654 (Revised 03/02) Weather Shield Mfg., Inc. Medford, WI 54451 715/748-2100

More information

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...

More information

Series 1 Steel Cable Ladder

Series 1 Steel Cable Ladder able Straight Sections See pages LDS-3 & LDS-4 Straight Section overs See page LDS-10 ccessories See pages LDS-5 - LDS-9 Fittings See pages LDS-11 - LDS-17 Fitting overs See page LDS-10 LDS-1 able Support

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume)

Selection Chart T-4000 Series Accessories (Part 1 of 5) Code Number Figure Description Application (High or Low Volume) Code No. LIT-1921710 Issued July 25, 2011 T-4000 Series Accessories Selection Chart T-4000 Series Accessories (Part 1 of 5) ( or Volume) F-100-20 F-300-30 F-300-34 F-300-31 F-300-35 F-500-45 F-300-30 Coupler,

More information

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings North America Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,

More information

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines NEMA Standards Publication VE 2-2000 Cable Tray Installation Guidelines Published by: National Electrical Manufacturers Association 1300 North 17th Street Rosslyn, VA 22209 Approved by: Cable Tray Institute

More information

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,

More information

SECTION 28 05 00 COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY

SECTION 28 05 00 COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY SECTION 28 05 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections, apply

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

KwikSplice cable tray system Save up to 50% on material and installation time

KwikSplice cable tray system Save up to 50% on material and installation time Cable management KSVP-14 KwikSplice cable tray system Save up to 50% on material and installation time KwikSplice cable tray system The KwikSplice cable tray systems innovative two bolt splice connection,

More information

Allen-Bradley 1397 400-600HP AC Line Filter Kit

Allen-Bradley 1397 400-600HP AC Line Filter Kit Installation Instructions IN Allen-Bradley 1397 400-600HP AC Line Filter Kit Cat. Nos. 1397-LF600 What This Option Provides What This Kit Contains This option is intended to be applied when the primary

More information

CTI TECHNICAL BULLETIN Number 6: A publication of the Cable Tray Institute

CTI TECHNICAL BULLETIN Number 6: A publication of the Cable Tray Institute CTI TECHNICAL BULLETIN Number 6: A publication of the Cable Tray Institute Circuit Integrity of Cable Tray Wiring Systems During Natural Disasters The January 17,1994 Los Angles, California earthquake

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Electrical Wiring Technical Bulletin

Electrical Wiring Technical Bulletin Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will

More information

Installation & Weatherproofing Guide for ENCOM Broadband Radios

Installation & Weatherproofing Guide for ENCOM Broadband Radios Installation & Weatherproofing Guide for ENCOM Broadband Radios Read the following instructions before proceeding with your ENCOM Wireless Radio installation. Keep these instructions in safe location for

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Whitepaper Modular Substation Cable Termination Design Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada Abstract The methods for cable penetrations into modular industrial substations are

More information

Plug-In Outlet Center Units

Plug-In Outlet Center Units Plug-In Outlet Center Units Plug-In Outlet Center Units Wiremold Plug-In Outlet Center Units bring power safely and conveniently to wherever you need it. These units are ideal for use in a wide variety

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Fiber Optic and Data Cabling Project Shelby Township Police Building

CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL. Fiber Optic and Data Cabling Project Shelby Township Police Building CHARTER TOWNSHIP OF SHELBY REQUEST FOR PROPOSAL The Charter Township of Shelby is soliciting proposals to install fiber optic and data cabling to serve a new Police Building that is under construction

More information

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware. 14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below: Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

More information

DSM http://www.dsmmfg.com 1 (800) 886-6376

DSM http://www.dsmmfg.com 1 (800) 886-6376 DESIGN GUIDE FOR BENT SHEET METAL This guide discusses how the bends are made, what thicknesses of sheet metal are commonly used, recommended bend radius to use when modeling the part, some practical limits

More information

SECTION 22 LIGHTNING PROTECTION SYSTEM

SECTION 22 LIGHTNING PROTECTION SYSTEM SECTION 22 LIGHTNING PROTECTION SYSTEM 22.01 SCOPE: A. These Specifications shall form a part of the Contract Documents and shall govern construction work for all buildings to be built or modified for

More information

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,

More information

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots 2.02 Standard Specifications General Entrances Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum entrance doors, door frames and hardware as shown

More information

InstaPATCH ZERO Solution Guide

InstaPATCH ZERO Solution Guide SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving

More information