1 Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12

2 Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710 General Information...45 Series 717 Low Rise Style... 6 Series 718 Horizontal Style... 7 Series 719 Vertical Style Meter Thread x Meter Thread... 8 Series 768 Horizontal "F" Style Flexible... 9 Meter Resetters 1 1 2" & 2" Vertical Inlet and Outlet Series 718 No Bypass...12 With Bypass...13 Accessories Gaskets...14 Meter Bushings / Adapters...14 Meter Dimensions...14 Tandem Options...15 Sectional View...15 Series 758 Crab Style Tandem...10 Inverted Tandem...10 Inline Tandem...11 Page 45 Page Series 718 Series Page Series Page XDCA Series 717 with Backflow Preventer and Thermal Expansion Tank (Tank must be purchased separately) XDCC Series 717 used to retrofit existing high rise meter pit and standard meter resetter with backflow preventer and pressure relief valve FAX sales@aymcdonald.com aymcdonald.com 1112

3 General Information A.Y. McDonald Mfg. Co. Resetters offer a wide variety of options for resetting your current water meter to various heights and locations. Resetters are used where the meter is already installed and the service lines are in place, but the meter needs to be relocated above or next to the current line. A.Y. McDonald Mfg. Co. resetters provide you with an array of variations that will see you through any relocation project. Common resetter installations are shown below. You can customize your resetter solution on the pages within, or contact our factory professionals to help you through. Brass materials meet or exceed AWWA C800 (latest revision) Copper tubing has a 13 16" O.D. for 5/8", 5/8" x 3/4" or 3/4" meter resetters, 1 1 8" O.D. for 1" meter resetters, 1 5 8" for 1 1 2" meter resetters and 2 1 8" for 2" meter resetters. Solder is nolead. EPDM rubber gaskets are furnished as standard. Contact factory for fiber or leather gaskets. All meter resetters are factory tested air under water at 85 PSIG. Brass support bar is standard on 18" and higher meter resetters. Meter resetter heights over 24" available on special order. All meter swivel nuts have wire seal hole. Lockwing ball style meter valves are standard. Meter swivel nuts with meter support saddle are standard, except where noted. All copper meter resetters can be supplied with a test valve on the outlet tubing. For dual check backflow valves, see catalog section 13. Brace eye hole accepts 1/2" iron pipe or PVC for 5/8", 5/8" x 3/4" and 3/4" meters and 1" vertical meter resetters. Brace eye hole accepts 3/4" iron pipe or PVC for 1", horizontal meter resetters. Brace eye hole accepts 1" iron pipe or PVC for 1 1 2" & 2", horizontal meter resetters. BEFORE AFTER FAX sales@aymcdonald.com aymcdonald.com 3

4 710 SERIES The A.Y. McDonald Meter Resetter is a unique and patented product designed to easily retrofit existing meter installations to include a dual check backflow preventer, or pressure relief valve. This is accomplished without the high risk of cutting into old service lines, or the expensive process of digging up and replacing existing meter boxes or pits. This retrofitting can be easily performed in even the most confined meter boxes. Before NOTE: Meter box sold separately Meter Dimensions Meter Size 5/8" 5/8" x 3/4" 3/4" AMeter Threads 3/4" 1" 1" BLay Length 7 1 2" 7 1 2" 9" A.Y. M c Donald Spacing* " " " After NOTE: Meter box sold separately Available for 5/8", 5/8" x 3/4", or 3/4" meters Cast Brass Meter Nuts with Rubber Gaskets Copper Tubing Cast Brass Base Meter Threads Patent No. 4,691,727 Dual Check Backflow Preventer (optional) Meter Threads ASSE listed dual check Pressure Loss Data 5/8" Series 710 with backflow 5/8" Series 710 without backflow 20 5/8" x 3/4" Series 710 with backflow 5/8" x 3/4" Series 710 without backflow 30 3/4" Series 710 with backflow 3/4" Series 710 without backflow WATER FLOW (Gallons Per Minute) WATER FLOW (Gallons Per Minute) WATER FLOW (Gallons Per Minute) PRESSURE DROP (Pounds per Square Inch) PRESSURE DROP (Pounds per Square Inch) PRESSURE DROP (Pounds per Square Inch) Thermal Expansion Warning Creating a closed condition in a hot water system with the installation of a nonreturn barrier (such as a Check Valve or Backflow Preventer between the system piping and the public supply) can result in extreme pressure rises caused by thermal expansion and/or water hammer. This thermal expansion can damage piping, valves, and other components in the system. The installation of a pressure relief device or thermal expansion tank can avoid possible damages FAX sales@aymcdonald.com aymcdonald.com 1112

5 Offset Left Standard 710 SERIES Approx. 6 Approx. 3 Side View 710 Inlet Series Style Meter Size Meter Height Meter Connections Bottom Bar 1/2" FNPT Space Tube Offset Options Bottom Bar Tap 710 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" R = Right offset A B Tap Locations Model NN 1 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 06 3" 6" 7" 12" Resetters with crossover meter sizes are available, contact factory. * For angle ball valves integral to resetter, contact factory. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements. * N N N = No valve (meter nut only without saddle) Q = Lockwing ball valve (without saddle) Side View 72 Left Offset Standard Inlet Model NN X72 = No option C = Dual check on inlet H = Dual check on outlet J = Adapter idler on outlet (sized to fit meter) U = UFR on outlet (Integral) A B Tap Locations X72 See above side view as required = No tap A = Tap inlet, no plug B = Tap outlet, no plug D = Tap outlet, with 125# PRV E = Tap inlet, with 175# PRV F = Tap outlet, with 175# PRV G = Tap inlet, with plug H = Tap outlet, with plug L = Tap inlet, with 125# PRV (Inlet is city side, outlet is house side) Ordering Options Separately Dual Check Backflow Preventer (Inlet side) 7113AN 34 For 5/8" meter 7113AN 44 For 5/8" x 3/4" and 3/4" meter Inlet: Male meter thread Outlet: Female meter thread (union) Dual Check Backflow Preventer (Outlet side) 7113NA 43 For 5/8" meter 7113NA 44 For 5/8" x 3/4" and 3/4" meter Inlet: Female meter thread (union) Outlet: Male meter thread Pressure Relief Valve 710P lb. rated 710P lb. rated 1/2" MNPT thread 710J11 Meter Adapter Idler (New Style) 3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 7 1 2" lay length 5/8" meter 710J22 Meter Adapter Idler 3 3/4" long with gasket, adapts basic 710 Series unit (less backflow preventer) to 7" lay length 5/8" x 3/4" meter 710J23 Meter Adapter Idler 1 1 2" long with gasket. Use with 710 Series unit and backflow preventer to increase lay length 3/4" meter Plug / FAX sales@aymcdonald.com aymcdonald.com 5

6 717 SERIES Low Rise Style Resetter 90º tubing to bottom bar is standard, contact factory for other options. The A.Y. McDonald 717 Series low rise resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve. It also offers several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Ninety degree tubing to bottom bar is standard, other options are available (contact factory for information). 90º Offset Right View Standard INLET Meter Thread OUTLET Meter Thread 717 Left Offset Inlet (city side) Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Optional Offset Tap Location Bottom Bar Tap 717 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" Tap A Offset Left: U = 5/8" V = 5/8" x 3/4" W = 3/4" X = Offset Left Tap D (bottom) Tap C (top) Tap B 2 1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1" 04 4" 6" for 1" meter only. For special heights, contact factory. W D C = Angle single check valve on outlet D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve X = No valve meter nut only For other special meter connections, contact factory. Outlet (house side) Model WD Right Offset Inlet (city side) Tap A Tap C (bottom) Tap B Tap D (top) Outlet (house side) = No Tap A = Inlet Left B = Outlet Left C = Outlet Top D = Outlet Bottom 45 = 45º 60 = 60º 180 = 180º = No tap A = 1/2" FNPT no plug B = 1/2" FNPT with brass square head plug C = 1/2" FNPT 125# PRV D = 3/4" FNPT no plug (only 1" resetter) E = 3/4" FNPT with brass square head plug (only 1" resetter) Series 717 is typically viewed from the inlet side, and is fabricated as a right offset (see photo above and at right). This is critical when considering tap locations. Left offset is available upon special request contact factory. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 1112

7 718 SERIES Horizontal Style Resetter Minimum 10" height on 1" resetters, or 12" on 1" resetter with angle dual check. The A.Y. McDonald 718 horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary. INLET Meter Thread OUTLET Meter Thread 718 Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Tap Location Bottom Bar Tap For Tandem Series 718 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" 2 1 = 5/8" 2 = 5/8"x 3/4" 3 = 3/4" 4 = 1" Model WX 07 07" 09" 10" 12" 15" 18" 21" 24" For special heights, contact factory. W X Blank = No Tap A = 1/2" FNPT inlet B = 1/2" FNPT outlet C = Angle single check valve on outlet D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve X = No valve meter nut only For other special meter connections, contact factory. Blank = No Tap A = 1/2" FNPT no plug B = 1/2" FNPT with brass square head plug C = 1/2" FNPT 125# PRV D = 1/2" FNPT 175# PRV 758 Series Horizontal Tandem Setter Example WX Tandem resetters are supplied with adapters and S tube. Please specify device length and threads when ordering. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 7

8 719 SERIES Vertical Style Resetter Meter Thread x Meter Thread The A.Y. McDonald 719 vertical to horizontal resetter allows you to reset a meter currently in a vertical position to a horizontal position incorporating an inlet or outlet shut off valve or check valve. It also offers several height options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Meter swivel nuts are less saddle 719 Model 7192 Series Style Meter Size Meter Height Meter Connections Bottom Bar FNPT Tap Location Bottom Bar Tap 718 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" 2 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" = Standard For special heights, contact factory. Q N Blank = No Tap A = 1/2" FNPT inlet B = 1/2" FNPT outlet A = Angle single check valve on outlet F = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valve N = No valve meter nut only For other special meter connections, contact factory. Blank = No Tap A = 1/2" FNPT no plug B = 1/2" FNPT with brass square head plug C = 1/2" FNPT 125# PRV D = 1/2" FNPT 175# PRV Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 1112

9 768 SERIES Horizontal "F" Style Flexible Resetter Minimum 15" height on 1" resetters. Resetters with crossover meter sizes are available, contact factory. The A.Y. McDonald 768 horizontal F Style (Flexible) resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve. It also offers several height options and flexibility if existing set is not aligned correctly. INLET Meter Thread OUTLET Meter Thread Model WX W X Series Style Meter Size Meter Height Inlet Outlet Meter Connections 768 = Standard For crossed sized meter sets A = 5/8" B = 5/8" x 3/4" C = 3/4" 1 = 5/8" 12" 2 = 5/8" x 3/4" 15" 3 = 3/4" 18" 4 = 1" 21" 24" For special heights, contact factory. C = Angle single check valve on outlet (Not availabe on 1") D = Angle dual check valve on outlet (ASSE 1024) W = Angle lockwing ball valve X = No valve meter nut only For other special meter connections, contact factory. For Tandem Series 761 Series Horizontal Tandem Setter Example WX Tandem resetters are supplied with adapters and S tube. Please specify device length and threads when ordering. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 9

10 758 SERIES Crab Style Tandem Resetter Made to set two 7 1 2" meter thread x meter thread devices. The A.Y. McDonald 758 tandem resetter allows you to reset a meter and a device in one low profile compact setting. Meter swivel nuts are less saddle Model 7582NN X N N X419 Series Style Meter Size Meter Height Meter Connections Blank Space Crab Style 758 Tandem = Standard 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" For special heights, contact factory. N = No valve meter nut only For other special meter connections, contact factory. Inverted Tandem For installing a regulator and meter in an existing setting and there is little room above 2" rise from original meter height. The A.Y. McDonald 758 inverted tandem resetter allows you to reset a meter and a device with minimal rise as long as there is room below the existing meter. Meter swivel nuts are less saddle Model NN X X406 Series Style Meter Size Meter Height Meter Connections Blank Space Inverted Style N N 758 Tandem = Standard 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" For special heights, contact factory. N = No valve meter nut only For other special meter connections, contact factory. Meter swivel nuts are less saddle. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 1112

11 758 SERIES Inline Tandem Resetter The A.Y. McDonald 758 inline tandem resetter with additional options for shut off or check valves plumbed into the tubing to accept inline, a meter and a pressure regulating device. Please supply device length and end connection configuration when ordering. Resetters include meter coupling and adapter and gaskets. Meter swivel nuts are less saddle INLET Meter Thread OUTLET Meter Thread Model QN X Q N X15.81 Series Style Meter Size Meter Height Meter Connections Blank Space Flange to Flange Spread 758 = Standard 1 = 5/8" 2 = 5/8" x 3/4" 3 = 3/4" 4 = 1" 07" 09" 10" 12" 15" 18" 21" 24" For special heights, contact factory. A = Angle single check valve on outlet F = Angle dual check valve on outlet (ASSE 1024) Q = Angle lockwing ball valve N = No valve meter nut only For other special meter connections, contact factory. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 11

12 718 SERIES Horizontal Style Resetters 1 1 2" & 2" No Bypass 1" Copper cross tube is standard for no bypass setters. The A.Y. McDonald " and 2 oval flanged horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers bypass options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary. Brass eye holes accept 1" iron pipe or 1" PVC. INLET Meter Flange OUTLET Meter Flange For Tandem Series 718 Series Style Meter Size Meter Height Inlet Outlet Meter Connections 718 = Standard No Bypass 6 6 = 1 1 2" 7 = 2" Lower heights may be available contact factory. Model WD 18 15" 18" 21" 24" For special heights, contact factory. Minimum height may apply based on configuration of setter. W D D = Angle dual check valve E = Angle dual check valve with 1" tap in cap with 1" NPT plug assembly F = Angle dual check valve with 1 1 2" tap in cap with 1 1 2" NPT plug assembly G = Angle dual check valve with 2" tap in cap with 2" NPT plug assembly N = Flanged elbow T = Flanged tee with 2" plug in top of tee for access W = Angle lockwing ball valve 758 Series Tandem Setter Example WD Tandem resetters are supplied with 610M adapters and S tube. Please specify device length and threads when ordering. Not all combinations available, contact factory with your requirements. Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 1112

13 INLET Meter Flange OUTLET Meter Flange 718 SERIES Horizontal Style Resetters 1 1 2" & 2" With Bypass The A.Y. McDonald " and 2" oval flanged horizontal resetter allows you to reset a meter incorporating an inlet or outlet shut off valve or check valve while offering several height options. It also offers bypass options and several options for taps to incorporate pressure relief valves or sampling valves before or after the meter. Depending on valve configurations, minimum heights may vary. Brass eye holes accept 1" iron pipe or 1" PVC 2" Meter flanges have slotted bolt holes to fit 1 1 2" or 2" meters Two drop in flange gaskets furnished. Two meter support brackets furnished. 1¼" bypass includes a 1" x 1" x 1 1 4" ball valve. Resetter with bypass requires a check valve or ball valve on outlet Cross sized resetters available, contact factory. 718 For Tandem Series B 6 Series Bypass Meter Size Meter Height Inlet Outlet Meter Connections = 1 1 2" 7 = 2" B = Low bypass R = High Offset Model 718B618WD 18 12" 15" 18" 21" 24" For special heights, contact factory. Minimum height may apply based on configuration of setter. W D D = Angle dual check valve E = Angle dual check valve with 1" tap in cap with 1" NPT plug assembly F = Angle dual check valve with 1 1 2" tap in cap with 1 1 2" NPT plug assembly G = Angle dual check valve with 2" tap in cap with 2" NPT plug assembly N = Flanged elbow T = Flanged tee with 2" plug in top of tee for access W = Angle lockwing ball valve 758 Series Tandem Setter Example WD Tandem resetters are supplied with 610M adapters and S tube. Please specify device length and threads when ordering. Setter Height B = Low Bypass 6.50 R = High Ofset Bypass Not all combinations available, contact factory with your requirements to right of meter Most Meter RESetters are Made to order and are not returnable. Please verify with the factory that the model number you have configured is available and meets your requirements FAX sales@aymcdonald.com aymcdonald.com 13

14 Gaskets METER MODEL DESCRIPTION SIZE 18G1 5/8" Rubber 5/8" 18G1F 5/8" Fiber 5/8" 18G1L 5/8" Waxed Leather 5/8" 18G2 3/4" Rubber 5/8" x 3/4" or 3/4" 18G2F 3/4" Fiber 5/8" x 3/4" or 3/4" 18G2L 3/4" Waxed Leather 5/8" x 3/4" or 3/4" 18G4 1" Rubber 1" 18G4F 1" Fiber 1" 18G4L 1" Waxed Leather 1" Two drop in flange gaskets furnished. Two meter support brackets furnished. METER MODEL DESCRIPTION SIZE 18G " FlangeRubber 1 1 2" 18G7 2" FlangeRubber 2" 4620G 1 1 2" RoundRubber 1 1 2" 4620G 2" RoundRubber 2" 2" Meter Flanges have slotted bolt holes to fit 1 1 2" or 2" meters. Meter Bushings Changes thread size only 10J12 Converts 5/8" meter spud to 5/8" x 3/4" meter spud two pieces required per meter 10J45 Converts 1" meter spud to 1 1 4" meter spud two pieces required per meter Meter Adapters Converts meter size and laying length 10J12KIT Converts 5/8" meter spud to 5/8" x 3/4" meter spud two pieces per bag 710J13 Converts 5/8" meter to 3/4" meter two pieces required per meter 710J46KIT Converts 1" meter to 1 1 2" flanged meter size and length two pieces per kit 710J13KIT Converts 5/8" meter to 3/4" meter two pieces per kit 710J47 Converts 1" meter to 2" flanged meter size and length two pieces required per meter 710J14 Converts 5/8" meter to 1" meter two pieces required per meter 710J47KIT Converts 1" meter to 2" flanged meter size and length two pieces per kit 710J14KIT Converts 5/8" meter to 1" meter two pieces per kit 710J23 710J24 Converts 5/8" x 3/4" meter to 3/4" meter one piece required per meter Converts 5/8" x 3/4" meter to 1" meter two pieces required per meter 710J24KIT Converts 5/8" x 3/4" meter to 1" meter two pieces per kit 710J34 Converts 3/4" meter to 1" meter two pieces required per meter 710J34KIT Converts 3/4" meter to 1" meter two pieces per kit 710J67 Converts 1 1 2" flanged meter to 2" flanged meter size and length two pieces required per meter two bolts included 710J67KIT Converts 1 1 2" flanged meter to 2" flanged meter size and length two pieces per kit four bolts included 710J67DH Converts 1 1 2" flanged meter to 2" flanged meter size and length two pieces required per meter Slotted holes for 1 1 2" or 2" meters does not include bolts and nuts 710J77DHX2 X1.75 Converts 2" x 15.25" flanged meter to 2" x 17" flanged meter size and length one piece required per meter. Slotted holes for 1 1 2" or 2" meters does not include bolts and nuts 710J46 Converts 1" meter to 1 1 2" flanged meter size and length two pieces required per meter 6121 Meter support bracket 1 1 2" and 2" Meter Dimensions Oval Flange Meter Size 5/8" 5/8" x 3/4" 3/4" 1" 1 1 2" 2" AMeter Threads 3/4" 1" 1" 1 1 4" 1 1 2" 2" BLay Length 7 1 2" 7 1 2" 9" " 13" 17" A.Y. M c Donald Spacing* " " " " 13.38" 17.38" *Allows for meter and two gaskets. Note: A.Y. McDonald uses the above standards for typical meter applications. If your application is special or in question, you should always measure the meter as shown above. Other meter lay lengths must be specified. An additional 3/8" is added to top spacing to allow for gaskets: Standard 2" top spacing = " FAX sales@aymcdonald.com aymcdonald.com 1112

15 Tandem Options All A.Y. M c Donald tandem copper setters are designed to provide the user with the option of placing an auxiliary device in addition to a water meter in a space as small as 18" in diameter (see Table I). The auxiliary device could be a pressure regulator, pressure relief valve, backflow preventer, etc. Table I shows typical lay lengths available for these devices. Other lengths can be provided. Contact our customer service department for details. Standard centerline spread for 5/8", 5/8" x 3/4", 3/4" meters is 7". 1" meter is 9". Tandem meter setter S bar (4619Ssize) and brass adapters (74619size) come as standard when ordering tandem resetters, but are also available separately (see below). Contact factory. Resetters with crossover meter sizes are available, contact factory. TABLE I Meter Size Device Minimum Length Recommended (FNPT x FNPT) Inside Pit Diameter 5/8" 4" to 5" 18" 5/8" x 3/4" 4" to 5" 18" 3/4" 4" to 5" 20" 1" 5" to 6" 21" Tandem "S" Bar 4619S 5/8" for use with 5/8" meter tandem 4619S 5/8" x 3/4" for use with 5/8" x 3/4" meter tandem 4619S 3/4" for use with 3/4" meter tandem Above items for use with 4"5" device 4619S 1 for use with 1" meter tandem Above item for use with 5"6" device "S" Bar Adapter Two pieces required per device /8" (5/8" meter x 3/4" NPT) /4" (5/8" x 3/4" or 3/4" meter x 3/4" NPT) " (1" meter x 1" NPT) 7" 9" Spread for 5/8", 5/8"x 3/4" and 3/4" Meters Spread for 1" Meters Note: Special length cross tubes and inverted tandem cross tubes are available, contact factory. Sectional View ASSE 1024 Angle Meter Valve Ball Style Angle Dual Poppet Check Valve Single Poppet Check Valve Double wall flange thickness Test Valve in Tubing Copper Tube Flange Meter Threads FAX sales@aymcdonald.com aymcdonald.com 15

16 A.Y. McDonald Mfg. Co. is a leading manufacturer of Waterworks Brass, Plumbing Valves, Pumps and Water Systems, and High Pressure Gas Valves and Meter Bars. The Company has distinguished itself with a proud tradition of quality and reliability since its founding in The mission of A.Y. McDonald Mfg. Co., in the words of our founder, is to make good products and sell them honestly. We, the stockholders and employees, accomplish this by extending the McDonald family culture through excellent customer service and by focusing on our customers needs. WARNING: It is unlawful in CALIFORNIA & VERMONT (effective 1/1/2010); MARYLAND (effective 1/1/2012); LOUISIANA (effective 1/1/2013) and the UNITED STATES OF AMERICA (effective 1/4/2014) to use any product in the installation or repair of any public water system or any plumbing in a facility or system that provides water for human consumption if the wetted surface area of the product has a weighted average lead content greater than 0.25%. This prohibition does not extend to service saddles used in California, Louisiana or under USA Public Law /12 More than a brand. We re a family. aymcdonald.com sales@aymcdonald.com

Copper Meter Insetters

Copper Meter Insetters Copper Meter Insetters To Set 5/8", 5/8" x 3/4", 3/4", & 1" Water Meters 1/1 Table of Contents Page Insetter Numbering System... 3 Meter Insetters 5/8", 5/8" x 3/4", 3/4", & 1" Series 740 "C" Style...45

More information

COPPER METER SETTERS 6-08. A.Y. McDONALD MFG. CO. WATER SERVICE PRODUCTS. TO SET 5/8", 5/8" X 3/4", 3/4", 1", 1 1/2", and 2" Water Meters

COPPER METER SETTERS 6-08. A.Y. McDONALD MFG. CO. WATER SERVICE PRODUCTS. TO SET 5/8, 5/8 X 3/4, 3/4, 1, 1 1/2, and 2 Water Meters COPPER METER SETTERS TO SET 5/8", 5/8" X 3/4", 3/4", 1", 1 1/2", and 2" Water Meters A.Y. McDONALD MFG. CO. WATER SERVICE PRODUCTS 608 A.Y. M c Donald Mfg. Co. is pleased to present its extensive line

More information

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P-24258 B-24258 E-24259 B-24259 B-24266 B-24267

8D.1 BALL ANGLE METER VALVES - 3/4 & 1 P-24258 B-24258 E-24259 B-24259 B-24266 B-24267 BALL ANGLE METER VALVES - 3/4" & " 8D. B-24258 MUELLER 300 Ball Angle Meter Valve MUELLER 0 Conductive Compression Connection for CTS O.D.* tubing x meter swivel nut** adding -3 suffix to catalog number.

More information

E FORD METER BOX COMPANY, NI

E FORD METER BOX COMPANY, NI THE FORD METER BOX COMPANY, INC. ISO 9001:2008 10002505 Section F 06/2011 Web Revision 07/25/2016 Ford Coppersetters, Linesetters and Resetters All Ford Meter Setters are assembled using lead-free solder.

More information

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com OUR PARTS PUT YOU IN THE PASSING LANE FUEL SYSTEMS Protect your fuel system. Velvac offers a wide range of locking fuel caps and anti-siphon tubes to keep unlawful occurances at bay. With OEM approved

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Hose Clamps & Fittings

Hose Clamps & Fittings All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw

More information

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

3, 4, 6 & 8 Model H Series Alarm Check Valve Installation and Maintenance Guide ", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,

More information

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

2013 Edition. Flanged fittings 30-64 NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61 30"-64" Ductile Iron industrial Applications, water & Wastewater 2 Table of Contents Flanged Fittings for Water 3 Flange Details 5 Flanged Fittings 6 90º and 45º Bend 6 22-1/2º and 11-1/4º Bends 7 Tees

More information

WATER PRESSURE REDUCING VALVES

WATER PRESSURE REDUCING VALVES MADE IN THE USA WATER PRESSURE REDUCING VALVES TABLE OF CONTENTS PRODUCT PAGE How Pressure Reducing Valves Work 3 36 Series 4 36C Series 6 36H Series 8 AUTOMATIC PRESSURE REDUCTION Pressure reducing valves

More information

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED Domestic and Non-Domestic Meter Regulators G940/G941 - Domestic Meter Regulator Domestic regulator offering high performance in a compact unit. Sizes:

More information

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Double-Headed Screw 1. 3/4 FIP x 3/4 MIP x 1/4 hole 2. 3/4 Fip x 3/4 MIP. Feed Water Connector 1. 1/2 FIP x 1/2 MIP x 1/4 OD 2. 3. Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable

More information

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

Manufactured under one or more of the following: U.S. Patent No. 4,614,113; 4,813,281

Manufactured under one or more of the following: U.S. Patent No. 4,614,113; 4,813,281 MUEE THEM-COI METE OX 8.1 Shaded area indicates change ev. 4-14 The MUEE THEM-COI Meter ox provides a means to allow a meter to be read and maintained even though it is set deep in the ground to resist

More information

08003-1 WATER SERVICE 2

08003-1 WATER SERVICE 2 08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

AIR OPERATED OIL PUMPS AND KITS

AIR OPERATED OIL PUMPS AND KITS PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model

More information

TYPE E Main Valve Sizes 3 /8 through 12

TYPE E Main Valve Sizes 3 /8 through 12 SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,

More information

Fixtures - Parts - Accessories to shampoo bowls

Fixtures - Parts - Accessories to shampoo bowls Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

OPERATING INSTRUCTIONS AND PARTS LIST FOR U075075 U100058 UNDERGROUND HOSE REELS

OPERATING INSTRUCTIONS AND PARTS LIST FOR U075075 U100058 UNDERGROUND HOSE REELS OPERATING INSTRUCTIONS AND PARTS LIST FOR U075075 U0005 FORM NO.: 3-00 REV: RAIN BIRD CORPORATION ONE REELCRAFT CENTER COLUMBIA CITY, IN 675 (00) -33 / (60) - FAX: (60) -605 U0005 MODEL NUMBER SIGNIFICANCE

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Mueller B-101 and A-3 Drilling and Tapping Machines

Mueller B-101 and A-3 Drilling and Tapping Machines TM TM Mueller and Drilling and Tapping Machines A guide to selecting Mueller Equipment Mueller TM TM and Drilling and Tapping Machines When it comes to line stopping and drilling and tapping technology

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.

More information

NITROUS TRANSFER PUMP INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.

More information

TAMPERS. 9949 Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A.

TAMPERS. 9949 Tabor Place, Santa Fe Springs, California, CA 90670, U.S.A. TAMPERS Website: www.apt-tools.com e-mail: info@apt-tools.com TDS-1064 Rev A S TOOL MAINTENANCE & REPAIR INFORMATION FIELD OPERATION: Before use: 1. Check the tamping butt lock screw, it must be tightened

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com

123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com 123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

MODEL G300 BRAKE BLEEDER

MODEL G300 BRAKE BLEEDER MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY

More information

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination

More information

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List For MG, WG, WGL, and Grinder Pumps for Effluent & Sewage CAUTION! Read these safety warnings first before

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

Watts Pure Water Systems

Watts Pure Water Systems Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before

More information

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS

SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work

More information

Model 1210C Battery Powered Pump Shown. Description

Model 1210C Battery Powered Pump Shown. Description 12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

Copper and Copper Alloy Tube, Pipe and Fittings

Copper and Copper Alloy Tube, Pipe and Fittings Copper and Copper Alloy Tube, Pipe and Fittings COPPER and COPPER ALLOY TUBE and PIPE Seamless Copper Pipe: Copper pipe is almost pure copper manufactured to the requirements of ASTM B 42 - Standard Specification

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

American- Darling 5¼" B-84-B-5.

American- Darling 5¼ B-84-B-5. -5 Sealed Lubrication Chamber Seals operating threads from water and debris which greatly reduces routine maintenance. Top Travel Stop Nut Helps prevent stem buckling and damage to bronze components which

More information

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version MASTER Water Conditioning Corp. Installation and Operation Manual MCA Time Clock Series Residential Softeners February 2011 Version Table of Contents Page No. Topic Description 1 Model # and Packaging

More information

GEET Fuel Processor Plans

GEET Fuel Processor Plans GEET Fuel Processor Plans This is a greatly simplified Proof of Concept version of the GEET Fuel Processor that just about anyone can build from parts from a local Hardware store in a weekend for very

More information

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by

More information

Goulds Water Technology

Goulds Water Technology APPLICATIONS Specifically designed for: Homes Farms Cottages Booster service SPECIFICATIONS Pump: Pipe connections: 1¼" NPT suction, 1" NPT discharge, 1" NPT drive (pressure) Pressure switch: AS4 preset

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

System Accessories Pricing. Page 0 Effective 7/02

System Accessories Pricing. Page 0 Effective 7/02 System Accessories Pricing Page 0 Effective 7/02 Firetrace Tubing 200005 Firetrace Detection Tubing (FDT) (Per Foot) (Available in continuous lengths up to 333 ft.) Accessories 400001 400004 400061 400060

More information

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001 Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001 Telescoping Post Indicator 2945 A 1" SQUARE STEM 9" MAX. = 10" MIN. = 7" FIELD ADJUSTMENT INSTRUCTIONS 1. Remove the top section from

More information

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL

SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL SURGICAL SCRUB SINKS INSTALATION-OPERATION-MAINTENANCE USER MANUAL California OSHPD Pre-approved Mac Medical 820 S Mulberry St. Millstadt, IL 62260 (618) 476-3550 phone (618) 476-3337 fax November 2007

More information

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

WD600 STEAM TRAPS. Thermodynamic Steam Trap

WD600 STEAM TRAPS. Thermodynamic Steam Trap WD600 Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company WD600, WD600L Sizes 3/8, 1/2, 3/4, 1 NPT Material Stainless

More information

MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2" - 2"

MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2 - 2 MAINTENANCE MANUAL INDEX DOUBLE CHECK ASSEMBLIES MODELS 850 & 850U 1/2" - 2" FEATURES AND OPERATING PROCEDURES VANDALISM GENERAL SERVICE PROCEDURES CUT-A-WAY DRAWING TROUBLE SHOOTING PROCEDURES CHECK MODULE

More information

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,

More information

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID

More information

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater

More information

Jay R. Smith Mfg. Co.

Jay R. Smith Mfg. Co. Jay R. Smith Mfg. Co. Automatic Backwater Valve SMITH CUSTOMER DRIVEN FLOOD-GATE FEATURES Index Page Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Valve

More information

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK 1 565AKHU HYDRAULIC 1.22 O-RING - 2 REQUIRED UNIT 1.23 O-RING COMPLETE 1.24 TEFLON O-RING 2 REQUIRED 1.3 EXTENSION SCREW 1.3A SPRING PIN 1.4 SPRING SUPPORT 1.5 SCREW BUSHING 1.6 Y SHAPE SEAL RING 1.7 HEAD

More information

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM Table of Contents General Description 1 Parts list 1 Installation 2 New Ground Loop 2 Retrofit 4 Temporary 6 Troubleshooting 8 INSTALLATION INSTRUCTIONS GEO-BOOSTER TM General Description The Geo-Booster

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

Cajon VCR Fittings. Flanges, Fittings, & Components. Cajon & Swagelok Fittings. Cajon VCR Fittings. Nuts, Caps, & Plugs. Socket Weld Glands

Cajon VCR Fittings. Flanges, Fittings, & Components. Cajon & Swagelok Fittings. Cajon VCR Fittings. Nuts, Caps, & Plugs. Socket Weld Glands Cajon VCR Fittings Cajon VCR Fittings Make excellent low-pressure gas connections Ideal for lecture bottle gas cylinders, standard helium checks, and general gas plumbing Withstand bakeout to 58º C (with

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

Series 30000 Hose Reels

Series 30000 Hose Reels Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are

More information

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

EXHIBIT A. Technical Specifications for Water and Sewer Service Lines EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding

More information

Fluid Monitoring and Inventory Management

Fluid Monitoring and Inventory Management SECTION FOUR Fluid Monitoring and Inventory Management Introduction Alemite meets your fluid monitoring and inventory management needs with its Accu-Guard systems and its Bigview Tank Monitor. These systems

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/392-5066 800/327-3022 800/476-2212 TOTAL MAINTENANCE SOLUTIONS

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/392-5066 800/327-3022 800/476-2212 TOTAL MAINTENANCE SOLUTIONS 8-1 BRONZE GATE VALVES 125 psi. SWP 200 psi WOG Threaded ends Non-rising stem Solid wedge disc DOMESTIC IMPORT PART # 40300250 1/4 40300260 40300251 3/8 40300261 40300252 1/2 40300262 40300206 3/4 40300263

More information

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

WATER & SEWER CORROSIVE RESISTANT PRODUCTS WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING

More information

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS SETTING UP THE PRESS FOR OPERATION For shipping convenience, the gauge, pump handle, hoist crank, screw nose and base angles

More information

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

Rental Services Temporary Cooling - Flexible Water Hose

Rental Services Temporary Cooling - Flexible Water Hose Engineering Bulletin Rental Services Temporary Cooling - Flexible Water Hose September 2006 CHS-PRB007-EN Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate

More information

Flare Fittings. The World Standard. SAE 45 Flared Fittings... D4. Inverted Flared Fittings... D14. Access Valves... D18

Flare Fittings. The World Standard. SAE 45 Flared Fittings... D4. Inverted Flared Fittings... D14. Access Valves... D18 Flare Fittings SAE 45 Flared Fittings... 4 Inverted Flared Fittings... 14 Access Valves... 18 The World Standard Flare Fittings Flare to ale PT 48F ale Connector 481FH ale Connector AVU1 ale Connector

More information

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................

More information

SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES

SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.

ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16. ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe

More information

Water Distribution Products Full-line product offering

Water Distribution Products Full-line product offering Water Distribution Products Full-line product offering Contents 03 Hydrants and Hydrant Security 04 Main Valves 05 Pipe Repair Products 06-07 Service Brass 08 Machines and Tools 09-10 Intelligent Water

More information

Installation Manual DIAPHRAGM WELL TANK

Installation Manual DIAPHRAGM WELL TANK Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of

More information

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing

More information

THE JERSEY CITY MUNICIPAL UTILITIES AUTHORITY REQUIREMENTS FOR FIRE AND DOMESTIC WATER LINE AND METER INSTALLATIONS

THE JERSEY CITY MUNICIPAL UTILITIES AUTHORITY REQUIREMENTS FOR FIRE AND DOMESTIC WATER LINE AND METER INSTALLATIONS THE JERSEY CITY MUNICIPAL UTILITIES AUTHORITY REQUIREMENTS FOR FIRE AND DOMESTIC WATER LINE AND METER INSTALLATIONS 1) All fire service applications and all domestic service applications two (2) inches

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER 1. BEFORE YOU BEGIN A. HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and

More information

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and

More information

e perts in our field CONTINENTAL PARTS CATALOGUE

e perts in our field CONTINENTAL PARTS CATALOGUE CONTINENTAL PARTS CATALOGUE NH3 Kits Tow Between Kit CON TBK1 Kit, Tow Between 1 CON TBK1-1/4 Kit, Tow Between 1¼ SVD Splitters and MVD Manifolds SVD Splitters and Repair Parts MVD Manifolds and Repair

More information

Transport & Automotive CATALOGUE. March 2011. Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au. www.tubefit.com.

Transport & Automotive CATALOGUE. March 2011. Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au. www.tubefit.com. Transport & Automotive CATALOGUE Customer Service Phone: 1800 777 299 Fax: 1800 065 321 Email:sales@tubefit.com.au March 2011 www.tubefit.com.au Page 1 4 6 9 12 14 16 17 19 20 22 23 24 26 28 29 31 33 Index

More information

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual STATFlow Direct-to-Drain System For use with STATIM 2000 and STATIM 5000 Autoclaves Installation Guide and Operator s Manual STATFlow Installation Guide and Operator s Manual 95-113193 Rev 2.0. Copyright

More information

Stainless Steel Single and Dual Circulation Kits

Stainless Steel Single and Dual Circulation Kits Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating

More information

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8 . Thermomax Solar Water Heater Thermo Technologies 5560 Sterrett Place, Suite 115 Columbia, MD 21044 Thermoteks.com November 2005 Installation Manual.......... Installation Procedure for Flatroof and Ground

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054 owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact

More information

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.

More information

Electronic Wallmount Faucet 1500T4 & 1501T4 Series

Electronic Wallmount Faucet 1500T4 & 1501T4 Series Electronic Wallmount Faucet 1500T4 & 1501T4 Series Specification: (example) Battery (4 C cell) or Hardwire (24 VAC) infrared electronic handwash system H 2OPTICS technology no external adjustments required

More information

Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+

Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric

More information

Fabricated Drainage Products

Fabricated Drainage Products Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage

More information