G 1 Alarm relay H 1 Dry alarm contacts TB 12

Size: px
Start display at page:

Download "G 1 Alarm relay H 1 Dry alarm contacts TB 12"

Transcription

1 ACS-PCM-5 POWER CONTROL MODULE FOR USE WITH RAYCHEM ACS-UIT INSTALLATION INSTRUCTIONS DESCRIPTION The ACS-PCM-5 provides ground-fault and line current sensing, alarming, switching (electromechanical relays) and inputs for five heat tracing circuits when used with the ACS-UIT. The ACS-PCM-5 enclosure is rated NEMA / and is approved for nonhazardous indoor and outdoor locations that are subject to freezing.these instructions describe how to mount the ACS-PCM-5 and make the various power, communications, and wiring connections. All electrical connections, maintenance and servicing must be done by a qualified electrician. If your application conditions are different, or if you have questions, please contact your Pentair Thermal Building Solutions representative or contact Pentair Thermal Building Solutions directly at (800) APPROVALS/CERTIFICATIONS Nonhazardous Locations UL STD 508A CAN/CSA C. NO. General Ambient Operating Temp. F to F ( 5 C to 50 C) Dimensions in. W X in. H X 6.75 in. D (60 mm W X 60 mm H X 7 mm D) Enclosure Rating NEMA / (Indoor/outdoor locations) Weight 70 lbs (.75 kg) Humidity 0 90% non-condensing Fuse Bussman MDL Input Vac (from Ch to power control devices) Control Contactors Rating -pole 0 A/pole 77 V Max Type Sprecher-Schuh CA7-6-0-D Quantity 5 Connection Terminals Power Supply/Line/Load # 8 AWG RS-85 # AWG # AWG TOOLS REQUIRED Drill to mount enclosure Small flat-head screwdriver Phillips (cross-head) screwdriver ADDITIONAL MATERIALS REQUIRED RS-85 cable (Belden #876 or Carol # C5) Wall fasteners for surface mounting (four screws) ACS-0 Programming Guide (H5879) ACS-UIT Installation Instruction (H589) Communication to ACS-UIT Type wire RS-85 Cable One shielded twisted pair Length 000 ft (00 m) maximum Quantity Up to 5 ACS-PCM-5 panels may be connected to one ACS-UIT. Line Current Sensors Max current Accuracy 60 A ± % of reading Ground-Fault Sensors Range 0 00 ma Accuracy ± % of range at 0 A line current Temperature Sensors Type Quantity 00-ohm platinum, -wire, α = ohm/ohm/ C Can be extended with a -conductor shielded cable of 0 ohm maximum per conductor Up to five wired directly to each ACS-CRM WARNING: IMPORTANT: FIRE HAZARD: Do not mount the ACS-PCM-5 in a hazardous location. SHOCK HAZARD: Follow all local electrical safety procedures. Disconnect power before servicing or opening this unit. The ACS-PCM-5 is an electronic unit. During installation, take the following precautions to avoid damage to its electronic components. Handle with care to avoid mechanical damage. Keep electronics dry. Avoid exposure to static electricity. Avoid contamination with metal filings, liquids, or other foreign matter. Take care to protect the user interface board on the enclosure door. Use agency-approved conduit bushings, adapters, and cable glands to keep the enclosure protected from dust and fluids. THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 / 8

2 Panel Layout Item Qty Description A ACS-CRM (card rack module) MSB LSB TB TB TB TB TB 5 TB 9 TB 7 TB 6 TB TB TB 5 TB 6 TB 7 C C C C C5 B NGC-0-CTM (current transfer module) C 5 -pole contactors D 5 Inputs E 9 Status LEDs F 0 77 Vac to Vdc power supply G Alarm relay H Dry alarm contacts TB I RS-85 (IN) terminal blocks J RS-85 (OUT) terminal blocks K 5 Line in terminal blocks L 5 Load out terminal blocks M Power supply input N Grounding bar ACS-PCM-5 Terminal Block Layout Alarm Relay (factory Alarm wired) Dry Contacts RS-85 Communications Heating Cable Power: 0 77 Vac Power Supply Input Heater Power Input Heater Power Output (factory wired) Com NC NO NO Com NC In Out Shld + Shld Front Panel Signal Light External device Heating cable power in and out: 0-77 Vac L L/N Ground Bar L L Heating cable Braid/Sheath Heating Cable Connection THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 / 8

3 Mounting the Enclosure The Raychem ACS-PCM-5 controller must be mounted in a nonhazardous location. The panel is rated NEMA / with an ambient range of F to F ( 5 C to 50 C). Heater Power Input and Ground (See schematic on Page ) Heater Power Input K and Ground N. Locate the Heater Power Input (K) terminal block (No 0) and connect per the ACS-PCM-5 Terminal Block Layout on page. Depending upon size and type of the remotely located branch circuit breakers*, use the appropriate size and number of wires from the circuit breaker to the Heater Power Input terminals.. Locate the Ground Bus bar (N) and using the appropriate size wire, connect a common ground wire from the branch circuit breaker panel board. Note:. The ACS-PCM-5 has integrated ground-fault circuit protection and therefore does not require additional ground-fault protection when connecting it to power.. Circuit breakers can be the following: (See schematic on Page ) Heater Power Output and Ground Heater Power Output J and Ground N. Locate the Ground Bus bar (N) and using the appropriate size wire, connect a ground wire from the ground bus bar to the heating cable s power connection enclosure and terminate to the heating cable s braid. Control Powe r No additional voltage supply is required to power the internal ACS-CRM board, alarm light and contactors. Theses devices are powered from Vac tapped from circuit heating cable power input. If a dedicated input power supply is required contact Pentair Thermal Building Solutions for assistance. # of Maximum Voltage poles Connection C.B. size *0 phase to neutral 0 A 08 phase to phase 0 A 0 phase to phase 0 A *77 phase to neutral 0 A *For 0 and 77 V, bring a separate neutral from each breaker THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 / 8

4 Jumper Jumper 0 0 MODEL NO: ACCS-PCM-5 ENCLOSURE: TYPE, VOLTAGE: MAX 77 VAC, PHASE, WIRE, 60 HZ 77 VAC MAZIMUM MODEL NO: ACCS-PCM-5 ENCLOSURE: TYPE, VOLTAGE: MAX 77 VAC, PHASE, WIRE, 60 HZ 77 VAC MAZIMUM 0 0 MODEL NO: ACCS-PCM-5 ENCLOSURE: TYPE, VOLTAGE: MAX 77 VAC, PHASE, WIRE, 60 HZ 77 VAC MAZIMUM MODEL NO: ACCS-PCM-5 ENCLOSURE: TYPE, VOLTAGE: MAX 77 VAC, PHASE, WIRE, 60 HZ 77 VAC MAZIMUM MODEL NO: ACCS-PCM-5 ENCLOSURE: TYPE, VOLTAGE: MAX 77 VAC, PHASE, WIRE, 60 HZ 77 VAC MAZIMUM Connecting the RS-85 Device Network The ACS-UIT display is typically linked to a network of Raychem ACS-PCM-5 power panels (incorporating the ACS-CRMs) and optional RMM devices. These are connected to the Raychem ACS-UIT using an RS-85 communication cable (shielded, two conductor, twisted pair). The following illustration shows how the RS-85 network for the ACS system can be configured. Device must be mounted in series. (Terminated devices are shown in gray) Branching of the network is not allowed. Connect no more than two RS-85 cables to any device. ACS-UIT RMM RMM ACS-PCM-5 ACS-UIT ACS-UIT 77 VOLTS ACS-PCM-5 ACS-PCM-5 77 VOLTS 77 VOLTS ACS-PCM-5 RMM RMM 77 VOLTS ACS-PCM-5 77 VOLTS In order for the RS-85 network to work properly, you must enable the termination resistor for the first and last device. The devices shown in gray in the illustration above represent the devices for which you must enable the termination resistors. The devices that are not grayed out represent the devices for which you should not enable the termination resistors. THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 / 8

5 Connection You must make an RS-85 connection from the ACS-UIT to the ACS-CRM board in the ACS-PCM-5 panel. To make this connection, a pre-wired terminal block has been provided in the ACS-UIT (TB- terminals,, and ) and in the ACS-PCM-5 panel (TB (H) and (I)). Connect the RS-85 wire from TB in the ACS-UIT and the other end to the TB (H) in the ACS-PCM-5 panel maintaining the correct polarity. If the ACS-UIT or ACS-CRM is the first or last device in the RS-85 network, see below for details on how to terminate the RS- 85 network. ACS-UIT To downstream devices (ACS-PCM-5, RMM) BMS gateway + + ACS-PCM-5 (Panel ) RS-85 Input Output ACS-PCM-5 (Panel ) RS-85 Input Output 5 5 T T RS-85 Field Port RS-85 Remote Port To next ACS-PCM-5 or RMM Termination of RS-85 Network (if First or Last in Network) ACS-UIT ACS-CRM A Pull-down Pull-up Termination ON RS-85- Termination RS-85- Termination MSB LSB Position Switch On Off Comments Pull-down (As-shipped default) RS-85 network signal is forced to a determinate state when idle. RS-85 network signal is not forced to a determinate state when idle. One device (typically this ACS-UIT) on the RS-85 network should force the network signal to a determinate state. Pull-up Termination (As-shipped default) RS-85 network + signal is forced to a determinate state when idle. (As-shipped default) RS-85 network is terminated with 0-ohm resistor. RS-85 network + signal is not forced to a determinate state when idle. RS-85 network is not terminated. One device (typically this ACS-UIT) on the RS-85 network should force the network + signal to a determinate state. Terminate the device (ACS-UIT or other) that is at each end of the RS-85 network, for a total of two terminated devices. No other devices on the network should be terminated. TB TB 9 TB 7 TB 6 Address Switches Inputs (x5) Alarm Output 5 6 End of Line (EOL) Jumper 6 If this device (ACS-CRM) is the last device in the RS-85 network, the J jumper needs to bemoved from terminals & to terminals &. TB TB TB TB TB 5 TB TB TB 5 TB 6 TB 7 Relay Outputs (x5) 5 Status LEDs 6 End of Line (EOL) jumper Normal position End of Line position THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 5 / 8

6 Optional RMM Installed in the Field Refer to the RMM Installation Instructions (H5688) for field installation instructions. You must connect an RS-85 cable from the RMM to the Raychem ACS-PCM-5 panel. To make this connection, a pre-wired terminal block has been provided in the Raychem ACS-PCM-5 panel. Connect the RS-85 wire from the RMM to the RS-85 terminal block (either H or I) while maintaining the correct polarity as shown below. If the RMM is the first or last device in the RS-85 network, connect the J7 termination jumper to pins and. If the RMM is not the first or last device in the RS-85 network, connect the J7 termination jumper to pins and. Connecting Sensors - As Required Inputs -wire s with shield may be connected to Ch thru Ch5 (TB TB5). per each ACS-CRM board The two common wires (usually red, red) are connected to terminals &, the source (usually white) to terminal and the braid to terminal (earth ground). connected directly to the CRM board Chassis Ground Terminal Number CH5 5 Red Red White CRM PCB CH CH Last RMM in network CH CH Default position (for all RMM units in network except first or last one) Termination mode (first or last RMM in network) Connecting External Device Input (Snow Controller, Override Device) The RMM uses address range 7. Refer to the RMM Heat Tracing Remote Monitoring Module Installation Instruction (H5688) for setting address switch. Setting Address Switches on CRM Board Address Switches (SW & SW) Each ACS-CRM must have a unique communication address. The valid address switch range for the ACS-UIT is 99. SW is the ones digit (0 9) and SW is the tens digit (0 9). Note: When adding an ACS-CRM to the system, you must first cycle power on the CRM board and then perform a network update at the ACS-UIT. 8 MSB SW LSB SW Connect -wire shielded cable from the normally open position of the external device dry contacts to the input terminals on the ACS-CRM Board. Connect the cable to terminals and with a jumper between position and as shown below: ACS-CRM Board Input Jumper ACS-PCM-5 Chassis Ground External Device or Snow Controller (Dry Contact) Ground No THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 6 / 8

7 Communications and Function Status LEDs Status LEDs 5 A cluster of 9 LED's are positioned on the CRM board which present the status of the circuit in the ACS-PCM-5 panel. MSB LSB TB TB 9 TB 7 TB TB TB TB TB TB 5 TB TB TB 5 TB 6 TB 7 Relay 5 (red) Rx (yellow) Tx (yellow) Relay (red) Relay (red) Address Switches Inputs (x5) Alarm Output Relay Outputs (x5) 5 Status LEDs 6 End of Line (EOL) jumper Relay (red) Relay (red) Alarm (red) Power (green) The following table summarizes the Status LEDs: Function Color Description Power Green Indicates power is supplied to the ACS- CRM board. Alarm Red Indicates that the ACS-CRM board registered an alarm condition. Check the ACS- UIT screen for events log to determine the alarm condition and to re-set the boards. Relay -5 Red Indicates that the heating cable relay is energized. Rx Yellow Flickering indicates data reception Tx Yellow Flickering indicates data transmission THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 7 / 8

8 NORTH AMERICA Tel: Fax: Tel: Fax: EUROPE, MIDDLE EAST, AFRICA Tel: Fax: ASIA PACIFIC Tel: Fax: LATIN AMERICA Tel.: Fax: Pentair is owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice Pentair. THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM5-IM-H5867 0/5 8 / 8

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED

More information

THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS t2000 Series Electronic heat-tracing controller Product Overview /COMMUNICATIONS INTERACE CARRIER REQ TO SEND The DigiTrace heat trace controller is designed to provide the benefits associated with single

More information

Industrial Control Solutions

Industrial Control Solutions Industrial Control Solutions NGC-30 Advanced Heat-Tracing Control System industrial heat tracing solutions www.pentairthermal.com Raychem ngc-30 Raychem NGC-30 is an advanced electronic multipoint control,

More information

NGC-30-CR -CRM -CRMS -CTM -CVM

NGC-30-CR -CRM -CRMS -CTM -CVM NG-0-R -RM -RMS -TM -VM ontrol and monitoring modules for use with the Raychem NG-0 Installation Instructions Description The NG-0-RM/-RMS and NG-0-TM provide ground-fault and line current sensing, alarming,

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

ACS-CRM CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM ACS-30 SYSTEM INSTALLATION INSTRUCTIONS

ACS-CRM CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM ACS-30 SYSTEM INSTALLATION INSTRUCTIONS AS-RM ONTROL AND MONITORING MODULES FOR USE WITH THE RAYHEM AS-0 SYSTEM INSTALLATION INSTRUTIONS APPROVALS/ERTIFIATIONS Hazardous Locations lass I, Div., Groups A,B,,D Ex n II T5 lass I, Zone, AEx n II

More information

Advanced Heat-Tracing Control System

Advanced Heat-Tracing Control System Advanced Heat-Tracing Control System Product Overview Heat-tracing system NGC-30 system Remote configuration and monitoring with Raychem Supervisor software The Raychem NGC-30 is a multi-circuit electronic

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,

More information

Product overview. 2000 mm. 100 mm

Product overview. 2000 mm. 100 mm Panel mounted electronic multi-circuit heat-tracing control, monitoring and power distribution system Product overview CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

NGC-30-CR NGC-30-CRM NGC-30-CRMS NGC-30-CTM NGC-30-CVM

NGC-30-CR NGC-30-CRM NGC-30-CRMS NGC-30-CTM NGC-30-CVM Installation Instructions NGC-0-CR NGC-0-CRM NGC-0-CRMS NGC-0-CTM NGC-0-CVM Industrial Heat Tracing Solutions EN-RaychemNGC0-IM-INSTALL R6 NGC-0-CR NGC-0-CRM NGC-0-CRMS NGC-0-CTM NGC-0-CVM Control and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

EMBEDDED ACCESS CONTROL Hardware Installation Guide

EMBEDDED ACCESS CONTROL Hardware Installation Guide EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel

More information

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual Freeze Protection Thermostats MODELS SST 2 Part Number 22744 MANUAL We Manage Heat Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 (574)

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Applied Electronics. Commercial Dimming System UPDATE NOTICE REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

RayClic Connection System Installation Instructions

RayClic Connection System Installation Instructions RayClic Connection System Installation Instructions Description RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit These kits are for use with Raychem IceStop, XL-Trace

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Comfort Control Relay Panel (CCRP)

Comfort Control Relay Panel (CCRP) CCRP9 "Commitment to Innovation" OPERATION & INSTALLATION GUIDE FOR Comfort Control Panel (CCRP) Off-Peak System Control 9 Pole CCRP 4 Pole CCRP (Applicable to Software Version 14.0-14.9) "Manufactured

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert AC4 User Manual TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Methods of Viewing and Configuring the Liebert AC4..............................

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

RayClic Connection System Installation Instructions

RayClic Connection System Installation Instructions F M -W RayClic Connection System Installation Instructions RayClic WARNING: Shock Hazard 718K Pipe Heating Cable with HWAT, IceStop, also Listed De-icing and and XL-Trace heating Snow Melting Equipment

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual Infrastructure Management & Monitoring For Business-Critical Continuity Liebert icom-do User Manual TABLE OF CONTENTS 1.0 INTRODUCTION............................... 1 2.0 INSTALLATION...............................

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

Fire Fighter Phone System Installation Instructions

Fire Fighter Phone System Installation Instructions Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).

More information

User Manual for CH-PFC76810

User Manual for CH-PFC76810 AA Portable Power Corp www.batteryspace.com, Email: Sales@batteryspace.com User Manual for CH-PFC76810 1. Overview The CH-PFC76810 charger is suitable for charging lithium ion battery packs such as those

More information

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

IO-DIM6 6-Channel, Digital to Analogue Converters

IO-DIM6 6-Channel, Digital to Analogue Converters Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication

More information

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence

More information

PowerLogic Sub Meter Display (SMD and SMDOPN)

PowerLogic Sub Meter Display (SMD and SMDOPN) Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting

More information

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved. ENGLISH EATS6 EATS6N Installation and user manual Copyright 05 EATON All rights reserved. Service and suppt: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES

COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES PRODUCT OVERVIEW XMI with standard MI cold lead and Type X connector MI cable heated section PRODUCT OVERVIEW XMI with PyroFLX cold lead

More information

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...

More information

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI000549 11/12/01

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI000549 11/12/01 KZ0224UW SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP INSTALLATION MANUAL KZMI000549 ISSUE DATE REVISIONS 1 November 2001 Initial release. 2001 BY ULTRAK ALL RIGHTS RESERVED ULTRAK CORPORATE OFFICE

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

IRT Eurocard. Type DAX-3206. Audio Extractor for 270 Mb/s SDI

IRT Eurocard. Type DAX-3206. Audio Extractor for 270 Mb/s SDI I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: 61 2 9439 3744 61 2 9439 7439 Email:

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

IO-RM3 3-Stage Relay Module

IO-RM3 3-Stage Relay Module Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Power supply unit Model: PAC-SC50KUA

Power supply unit Model: PAC-SC50KUA Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

HSG Engineering Tech Bulletin

HSG Engineering Tech Bulletin Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for

More information

Operating Instructions. UL325 Compliant Non-monitored

Operating Instructions. UL325 Compliant Non-monitored IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

Installation Guide Solar Connect-11

Installation Guide Solar Connect-11 Installation Guide Solar Connect-11 Version 1.1 Contents Important Product Information 3 System Registration Form 4 Solar Connect-11 Overview 5 Internet & Power Connections 6 Single Phase CT Connections

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION GE Lighting Installation Instructions Lighting Controls Centralized Lighting Control Panel Interior Catalog Number CLCINTxx DESCRIPTION The Centralized Lighting Control System is a small network of relay

More information

WIRELESS READER INTERFACE - INDOOR

WIRELESS READER INTERFACE - INDOOR INSTALLATION INSTRUCTIONS WIRELESS READER INTERFACE - INDOOR (WRI-IN-12VDC or AUWRI-IN-12VDC) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-014-C

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

Configuration Instructions

Configuration Instructions READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System ELITE-L Series ELITE - Low Voltage / Dry contact Remote Control System Applications Garden Lighting Pond pumps Remote outdoor Switching Access control Industrial control Features 4 switched channels 1000W

More information