SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings
|
|
- Evangeline Snow
- 8 years ago
- Views:
Transcription
1 Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac: HP 08/0 Vac: HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams... Frame, Contactor Wiring Diagrams... Frame, Contactor Wiring Diagrams... Frame, Contactor Auto-bypass Wiring Diagrams...5 Smart Frame Dimensional Diagrams...6 Frame : NEMA, Disconnect Only and Contactor...6 Frame NEMA, Contactor and Contactors with Auto-Bypass...7 Frame NEMA, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass...8 Frame NEMAR, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass
2 SMART FRAME WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS A B VREF: REFERANCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILLARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT W V U SMART U V W ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED. TS, ENCLOSURE FAN STANDARD ON ALL NEMA R PANELS. ENCLOSURE FAN ON 0HP, 0HP, AND 00HP AT 80V. HEATER IS OPTIONAL ON ALL NEMA R PANELS. TRANSFORMER ONLY REQUIRED ON R MODELS. DISCONNECT PANEL HAS FUSED MAIN DISCONNECT. DRIVE ONLY PANEL HAS WIRE TERMINALS. ON DRIVE ONLY PANEL, CUSTOMER IS RESPONSIBLE FOR BRANCH CIRCUIT AND SHORT CIRCUIT PROTECTION. ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION DIP SWITCHES ON RS85 A0 AI AI LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD M6 Fig.. Frame, Fused Disconnect Wiring Diagrams
3 A B VREF: REFERANCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILLARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT W V U SMART U V W ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED. IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. TS, ENCLOSURE FAN STANDARD ON ALL NEMA R PANELS. ENCLOSURE FAN ON 5HP AND LARGER AT 80V. HEATER IS OPTIONAL ON ALL NEMA R PANELS. ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION DIP SWITCHES ON RS85 A0 AI AI LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD M5 Fig.. Frame, Contactor Wiring Diagram
4 L L /. /. SHIELD ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD. AI 0-0 VDC OR - 0 ma SHD AT FIELD END USE CONDUCTOR SHD, TWISTED PAIR WIRE AI 0-0 VDC OR - 0 ma SPEED REFERENCE NOTE : ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED, SEE DETAIL B NOTE : IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. NOTE : TS, ENCLOSURE FAN STD ON ALL NEMR PNLS. ENCLOSURE FAN, ON 5HP & 80V. HEATER IS OPTIONAL ON ALL NEMA R PNLS. AI AI TEST AO START COMMAND ON RS85 ST SEL SW POSITION DIC DOC BC A B 5 6 DIP SWITCHES DETAIL B +0VREF: REFERENCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILIARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. SS - FOUR POSITION SEL. SW. DETAIL A SEE NOTE FAN ENCLOSURE CIRC FAN SEE NOTE RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT TB 8 FAN ENCLOSURE CIRC FAN SEE NOTE TS TB SEE NOTE BUILT IN T-STAT L T.5 TB HEATER TB ENCLOSURE HEATER SEE NOTE W L T V X Y X RUN L T U SMART U V W SS SEE DETAIL A LT SEE NOTE.5 DIC X000. A A 6 CONTACTOR DOC OL 7 8 BC T T T DOC.5 L L L 000X G X X RUN L T L T LT L T L T TB T BC.57 L T OL.57 L T TB T M MOTOR HP RPM AMP 000X.57 A A 5 DRIVE OUTPUT CONTACTOR BC DOC TB T 00X0 A A TEST 9 DRIVE INPUT CONTACTOR DIC T T T DIS MAIN FUSED DISC. FU, FU, FU, CLASS J, TIME DELAY FFSI TB SEE NOTE J 50V, MIDGET SECONDARY FUSE TB FU6 L L L CUSTOMER SUPPLIED FREEZE/FIRE/SMOKE INTERLOCK CLASS CC PRIMARY FUSE T CONTROL TRANSFORMER CLASS CC PRIMARY FUSE FU5 LINE, PHASE, 60 HZ FU L/.0 L/.0 M05 Fig.. Frame, Contactor Wiring Diagram
5 L L /. /. SHIELD AI 0-0 VDC OR - 0 ma SHD AT FIELD END USE CONDUCTOR SHD, TWISTED PAIR WIRE AI 0-0 VDC OR - 0 ma SPEED REFERENCE ST START COMMAND.5.6 TB 0 DOC BCR 0 /.6 / A B VREF: REFERENCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI V OUT: V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +VIN: V AUXILIARY INPUT RS85: NEGATIVE RS85: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT L T.5 W L T V L T U SMART U V W SEE NOTE DIC T T T DOC.5 L L L L T L T L T L T TB T TB T M MOTOR HP RPM AMP BC.57 L T OL.57 L T TB T T T T DIS MAIN FUSED DISC. FU, FU, FU, CLASS J, TIME DELAY L L L LINE, PHASE, 60 HZ ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION NOTE : ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS AS FACTURY DEFAULT EXCEPT PARAMETERS M.5..6, WHICH IS SET TO SLOT 0., AND M.5..0 WHICH IS SET TO SLOT A.. THESE CHANGES ARE FOR ENABLE FOR AUTO CONTROL. SET DIP SWITHCHES SHOWN IN DETAIL B AS REQUIRED. NOTE : IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. NOTE : TS, ENCLOSURE FAN STD ON ALL NEMR PNLS. ENCLOSURE FAN, ON 0, 0 & 80V. HEATER IS OPTIONAL ON ALL NEMA R PNLS. NOTE : RELAY BCR, BC N.O. CONTACT (PG), TERM, 5, 6, 7, 9, 0 - AUTO OPTION. REMOVE JUMPER J FOR MANUAL. DIN - RUN ENABLE, RO - DRIVE FAULT. LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD. AI AI AO TEST ON RS85 SEL SW POSITION DIC DOC BC DIP SWITCHES DETAIL B SS - FOUR POSITION SEL. SW. DETAIL A CUSTOMER REMOTE INDICATION TERMINALS SEE NOTE - AUTO OPTION /.57 TB BC 9 5 TB 0 NOTE FAN ENCLOSURE CIRC FAN SEE NOTE TS TB 8 FAN TB ENCLOSURE CIRC FAN SEE NOTE TB HEATER TB ENCLOSURE BUILT IN T-STAT HEATER NOTE SEE NOTE NOTE /. SEE NOTE - AUTO OPTION /. A A TB 6 RBC TB 7 CONTROL RELAY BCR CUSTOMER REMOTE CONTACT Y X X SS SEE DETAIL A RUN LT X A A 6 DOC 7 OL 8 CONTACTOR BC 000X.6 AUTO JUMPER TB 5 000X.6 BCR B TB.57 J LT X G X RUN A A DRIVE OUTPUT CONTACTOR BCR BC A 5 DOC 9 00X0 A A DRIVE INPUT CONTACTOR TEST DIC SEE NOTE J 50V, MIDGET SECONDARY FUSE CUSTOMER SUPPLIED FREEZE/FIRE/SMOKE INTERLOCK FFSI TB TB FU6 CLASS CC PRIMARY FUSE T CONTROL TRANSFORMER CLASS CC PRIMARY FUSE FU5 FU L/.0 L/.0 M06 Fig.. Frame, Contractor Auto-bypass Wiring Diagrams
6 D D BACK RESET LOD TEST OK STOP START H H W D* D W NEMA DISCONNECT ONLY AND CONTACTOR FRAME SIZE HP AND CONFIGURATION DIMENSIONS WEIGHT 08/0 VAC 60 VAC W W H H D D D LB HP.5-7.5HP DISCONNECT *DEPTH OF CONT ONLY -CONTRACTOR * M59A Fig. 5. Frame : NEMA, Disconnect Only and Contactor Dimensional Drawings
7 D D BACK RESET LOD TEST OK STOP START RUN A RUN G H TEST H I ON O W D W NEMA CONTACTOR AND CONTACTOR WITH AUTO FRAME SIZE HP AND CONFIGURATION DIMENSIONS WEIGHT 08/0 VAC 60 VAC W W H H D D D LB HP.5-7.5HP -CONTRACTOR -CONTRACTOR WITH AUTO M50A Fig. 6. Frame NEMA, Contactor and Contactors with Auto-Bypass Dimensional Drawings
8 BACK RESET STOP Bypass Run OK Bypass Off LOC REM START Run Test SMART FRAME WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS (5) W H H I ON 0 A G SEE NOTE H D (5) D D W M50 Frame Size HP and Voltage Dimensions Weight 08/0 Vac 60 Vac Configuration H H H W W D D* D Lb. 0.75HP HP.5HP HP HP 0.75HP HP.5HP HP HP.5HP HP HP HP 5HP 7.5HP.5HP HP HP HP 5HP 7.5HP Disconnect Only Contactor -Contactor -Contactor with Auto-Bypass Fig. 7. Frame NEMA, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass
9 D EXHAUST SHROUD W I ON -/6 (56) 0 SEE NOTE H Bypass Run A Run G H Bypass Off Test FAN SHROUD D D W -/6 (56) QTY () QUARTER TURN LATCH ON FRAME. QTY () QUARTER TURN LATCH ON FRAME 5 AND 6. THREE POINT LATCHING WITH EXTERIOR DOOR HANDLE ON FRAME 7 AND 8. M50 Frame Size HP and Voltage Dimensions Weight 08/0 Vac 60 Vac Configuration H H W W D D Lb. 0.75HP, HP,.5HP, HP, HP.5HP, HP, HP, HP, 5HP, 7.5HP Disconnect Only Contactor Contactor Contactor with Auto-Bypass Fig. 8. Frame : NEMAR, Disconnect Only, Contactor, Contactor and Contactor with Auto-Bypass
10
11 6-79 0
12 Automation and Control Solutions Honeywell International Inc. 985 Douglas Drive North Golden Valley, MN 55 customer.honeywell.com U.S. Registered Trademark 0 Honeywell International Inc M.S. Rev. 0- Printed in United States
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationSmartVFD HVAC and BYPASS
SmartVFD HVAC and BYPASS The Smart Choice for Energy Savings. Saving Energy the Smart Way Buildings consume more than 70 percent of the electricity produced in North America and roughly half of that is
More informationSolid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationVLT 6000 HVAC. Contents
Contents Introduction Safety...3 Safety Guidelines...3 Warnings Against Unintended Start...3 Introduction...4 About this manual...4 Assumptions...4 References...4 Trademarks...5 Programming the VLT 6000
More informationNELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL
NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL CONTENTS GENERAL INFORMATION...3 INSTALLATION...3 FIELD WIRING...4 PROGRAMMING...4 Circuit Monitor Options...5 Power Frequency...5 Alarm Silence
More informationImpulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations
Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1
ACH550 E-Clipse Bypass User s Manual 2-1 ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives 1 400 HP User s Manual ACH550-EB_UM (3AUA0000016461) Rev D EN EFFECTIVE: 2010-04-01 SUPERSEDES: ACH550-EB_UM (3AUA0000016461)
More informationSECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
More informationDORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
More informationEQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
More informationVCM Installation and Operations Manual. Table of Contents
Table of Contents VCM Installation and Operations Manual 1.0 Introduction... 1 2.0 Product Inspection... 2 2.1 Nameplate Layout... 2 3.0 Operating Precautions... 3 3.1 Before Power up... 3 3.2 During Power
More informationLiebert Universal Monitor
Infrastructure Management & Monitoring For Business-Critical Continuity Liebert Universal Monitor User Manual TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Methods of Viewing and Configuring the Liebert Universal
More information..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual VLT 6000 Series Adjustable Frequency Drive 12/01 23-6108-00 Revision K Rotating shafts and electrical equipment can be hazardous. Therefore, it is strongly
More information9000X AF Drives. User Manual. May 2011 Supersedes June 2009
9000X AF Drives User Manual May 2011 Supersedes June 2009 9000X AF Drives Disclaimer of Warranties and Limitation of Liability The information, recommendations, descriptions, and safety notations in this
More informationMAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
More informationInstalling the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
More informationCENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit
Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin
More informationACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program
ACS800 Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program Master/Follower Application Guide Supplement to Firmware Manual ACS800 Standard Application
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationA1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
More information3PH2 or 3PHE 3 Phase Control Board
3PH2 or 3PHE 3 Phase Control Board The 3-Phase Control Board is used to control automatic doors or gates that operate with 3-Phase or high current single-phase motors in high usage residential and commercial
More informationWATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING
WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING DESCRIPTION: An electronic control panel used in conjunction with one pulse meter (water meter with pulse output proportional to flow rate)
More informationCM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
More informationNXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationGPD 506/P5 Start-up Procedure and Checklist
GPD 506/P5 Start-up Procedure and Checklist Preparation for GPD506/P5 Drive Start-Up...2 HVAC Start-Up Procedure for GPD 506/P5 WITH Bypass Option:...4 HVAC Start-Up Procedure for GPD 506/P5 WITHOUT Bypass
More informationSECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030)
PART 1 - GENERAL SECTION 13XXX CONTROL DESCRIPTION (DICP Models 02-412NC, 412, 622, 826, 1030) 1.01 SUMMARY This section describes the operation and control of a drip irrigation system. The major components
More informationThe HVAC SOLUTION DELIVERING POWER...SAVING ENERGY
The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect
More informationPowerFlex 700 and 700H Packaged Drives. Technical Data
PowerFlex 700 and 700H Packaged Drives Technical Data Overview The heart of every PowerFlex 700/700H packaged drive package is a PowerFlex Adjustable Frequency Drive. The packaged drives program provides
More informationTAKEDO -3VF V20 INSTRUCTION MANUAL. www.sms.bo.it 3 18-10-2013. REL. DATE T.M. Check and Approval
TAKEDO -3VF V20 INSTRUCTION MANUAL 3 18-10-2013 REL. DATE T.M. Check and Approval www.sms.bo.it PAGE INTENTIONALLY LEFT BLANK 1 INTRODUCTION TAKEDO-3VF V20 is a new type of drive with built-in EMC filter,
More informationTAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
More informationWD-AMX Water Detection Controllers
Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation
More informationvacon compact ac drives creating perfect harmony
vacon compact ac drives creating perfect harmony what is harmony? We see harmony as a state of balance. The feeling that the solution created is the best possible for your specific needs. That the supplier
More informationRMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
More informationNX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
More informationFlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3
FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3 Instruction Manual D2-3405-2 The information in this manual is subject to change without notice. Throughout this manual, the following
More informationTAC I/NETTM MR-AHU-HP. Application Specific Controller
TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms
More informationOperation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
More informationABB HVAC Drives ACH400 Vertical Electronic Bypass to ACH550 E-Bypass, 1-25Hp @ 208V, 1-50Hp @ 480V (R1... R4 Frame Size Drives)
ABB HVAC Drives ACH400 Vertical Electronic Bypass to ACH550 E-Bypass, 1-25Hp @ 208V, 1-50Hp @ 480V (R1... R4 Frame Size Drives) Retrofit Guide PRODUCTS ACH400 to ACH550 Drive Replacement Instructions This
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More information2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationINSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
More informationIMS ALARM 3 PORT RS485 EXPANSION BOX
Price $.00 IMS ALARM 3 PORT EXPANSION BOX OPERATING INSTRUTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT 920147.fm TABLE OF ONTENTS GENERAL SPEIFIATIONS... 3 INTRODUTION... 4 RS232 ONNETION... 4 OMPATIBILITY...
More informationVSD Series Drives. November 2009 Supersedes September 2006. Powered by Eaton Technology. User Manual
Powered by Eaton Technology VSD Series Drives User Manual Supersedes September 2006 LIT-1201828 For more information visit: www.johnsoncontrols.com Powered by Eaton Technology VSD Series Drives User Manual
More informationCONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING
PART 1-GENERAL 1.01 DESCRIPTION A. This specification is to cover a complete Variable Frequency motor Drive (VFD) consisting of a pulse width modulated (PWM) inverter designed for use on a standard NEMA
More informationD287/D288/D292/D293A/D293E
D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationMultipoint Scanning Alarm System
Multipoint Scanning Alarm System Many gas detection applications require multiple sensing locations to provide adequate area protection for plant personnel. Signals from a variety of field measurement
More informationApplied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationBACnet Automation Interface Module (Network Version)
Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationUnidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationTable of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
More information3FBD DC Motor Drive User Manual
3FBD DC Motor Drive User Manual Via I. Alpi 6 - zona industriale - Lonato (BS) Tel. +39 30 9913491 r.a. Fax. +39 30 9913504 http://www.re-elettronica.it info@re-elettronica.it Pag. 1 Index Index... pag.1
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationUser manual Rev 1.3 Contents
User manual Rev 1.3 Contents 1. Introduction...4 2. System specifications...5 2.1.. General overview...5 2.2. Maximum capacity...6 2.3. Electrical specifications...6 2.4. Mechanical specifications...6
More informationWiring diagrams. Compact NSX. Contents
Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable
More informationSenseLink TM. End-Point Controller. Addendum
SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA 95054 Main: 408.235.7620 Fax: 408.235.7625 SenseLink
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationConnecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations
Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationHM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
More informationFX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
More informationALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
More informationconventional system operation
conventional system operation detection line operation Conventional detection systems normally operate on a 24VDC line. In the standby condition, the detectors will draw a low current, typically less than
More informationContact Center CC-165 INSTALLATION & USER'S GUIDE
Contact Center CC-165 INSTALLATION & USER'S GUIDE Table of Contents Introduction... 2 Specifications... 2 J4 Host Communications... 2 J5 and J12 (upper board)... 3 J6, J13, and 14 Input Connections...
More informationElectronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
More informationShort Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
More informationA.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:
Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM
More informationT7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationTrouble Shooting Guide
Trouble Shooting Guide WWTP - Control Panel CP-1 & Remote Annunciator Panel Reference: Schematics SCOPE The following trouble shooting guide has been specifically prepared for this system and primarily
More information2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog 2011. www.toshiba.com/ind
www.toshiba.com/ind 2011 Toshiba International Corporation Rev. 110504 Industrial Catalog 2011 13131 W. Little York Road Houston, TX 77041 Tel: 713-466-0277 Fax: 713-466-8773 US: 800-231-1412 Canada: 800-872-2792
More informationWater Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationController Automation, Model II+
Controller Automation Page 2 of 2 Automation with the RADAK II+ power controller II+ I/O Points: Inputs 5 Programmable Digital inputs 2 Dedicated digital inputs (Channel select and External SCR control
More informationTransfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch
Transfer Switch 30 Amps STS-30 Owner's Manual Please read this manual before operating your transfer switch Section 1 Introduction Function of a Transfer Switch In case of failure of the main AC power
More informationGlossary of Common Crane Ter ms:
Glossary of Common Crane Ter ms: 26 Adjustable brakes: Electro-mechanical device to control crane deceleration. Bridge beam: Traveling beam connected to end trucks - supports trolley hoist and load. Bumpers:
More informationMaster Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationSpecification Requirements DBL 700MX and 1000MX Series UPS
Specification Requirements DBL 700MX and 1000MX Series UPS Theory of Operation Upon loss of utility power, the UPS inverter shall continue to provide seamless pure sine-wave AC from the batteries without
More informationRP1r. Extinguishing Control Panel. User Manual (Software version 3.x) 3 zone control panel to protect 1 extinguishing risk
EN12094:1/2003 Honeywell Life Safety Iberia C/Pau Vila 15-19 08911 BADALONA (BARCELONA) Tel.: 93 497 39 60 Fax: 93 465 86 35 www.honeywelllifesafety.es Extinguishing Control Panel RP1r 3 zone control panel
More informationDC disconnects for solar photovoltaic installations. Connecting the. power of the sun
DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these
More informationAutomatic Transfer Switch Controller
Automatic Transfer Switch Controller Decision-Makerr MPAC 1500 Model KBS with Decision-Makerr MPAC 1500 Controller Applicable Models Model Description KCS Standard-Transition Any Breaker ATS ] KCP Programmed-Transition
More informationmecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
More informationInstallation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types
Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:
More informationPSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
More information