CEP7-E Electronic Motor Protection Relays

Size: px
Start display at page:

Download "CEP7-E Electronic Motor Protection Relays"

Transcription

1 CEP7-E Electronic Motor Protection Relays Motor protection with leading edge technology, expandable protection and communication. MOTOR CONTROL AND DRIVES NHP Electrical Engineering Products Pty Ltd AUS NZ 3 NHP NHP 8 NHP NHP nhp.com.au nhp-nz.com

2 The New CEP7 Overloads Now Boast a Formidable Range of Smart Add-On Modules CEP7-ERR REMOTE RESET MODULE CEP7-EJM JAM PROTECTION AND REMOTE RESET MODULE CEP7-EGJ GROUND FAULT / JAM PROTECTION AND REMOTE RESET MODULE CEP7-EPT PTC THERMISTOR RELAY AND REMOTE RESET MODULE CEP7-EGF GROUND FAULT PROTECTION AND REMOTE RESET MODULE Side mount modules also deliver entry level communication with DeviceNet TM, Profibus and Ethernet / IP: CEP7-EDN DeviceNet TM communication module - available for fully adjustable jam / stall protection and thermal warning to indicate imminent overload trip CEP7-EPRB Profibus communication module includes warning for jam trip, overload and underload. Includes device trip and warn status CEP7-ETN Ethernet / IP communication module with built-in webserver support for configuration and monitoring CEP7-DNCT - hand held programming terminal includes one metre cable to be used with CEP7-EDN (DeviceNet TM module) EASY TO DO BUSINESS WITH NHP ELECTRICAL ENGINEERING PRODUCTS PTY LTD 3 NHP NHP nhp.com.au

3 CONTACTOR SELECT IPHONE APP New contactor and overload selection tool Calculates full load current of 3-phase motors based on. kw Voltage (45, 69 and V AC) Selection made easy by providing part numbers and product photo. AVAILABLE FROM THE ITUNES APP STORE NOW! Contents Introduction to CEP7 electronic overload relays...3 CEP7-ED standard electronic overload relays...5 Overview of CEP7-EE features...6 CEP7-EE enhanced electronic overload relays...7 CEP7-E_P pass through electronic overload relays...8 CEP7 side mount modules...9 CEP7-CBCT core balance transformers and communication modules... Accessories... CEP7 quick reference guide... 3 Dimensions... 5 CEP7 module technical information... 7 CEP7-ETN Ethernet Network Communication Module... 2 CEP7-CBCT core balance transformers (technical information)... 2 Trip curves Technical information

4 ROBUST MOUNTING TO CONTACTOR 27A 55A Electronic overload relays CEP7 comprehensive motor protection Sprecher + Schuh have introduced their new CEP7, second generation electronic overload protection relays. The new CEP7 overloads incorporate a greater use of sophisticated electronic control and monitoring. With recent advances in micro electronic technology and the introduction of the ASIC chip set, it has become possible to improve on and add new features to the popular CEP7 range. The CEP7 second generation overload now incorporates greater accuracy and versatility whilst providing increased overall protection. The new CEP7 incorporates the following improved features: A wider settable current range (5:) Adjustable class trip settings (, 5, 2 and 3) (EE version) Field installable side mount modules (EE version) An extremely low power consumption Robust mounting to contactor Dip switch settings (EE version) 9A 8A Range overview CEP7-ED basic model The CEP 7-ED is the standard or base model version. The ED model is available in the current range of. - 45A, incorporates a fixed trip class of, and is suited to 3 phase operation. A manual reset function, visible trip indicator and test / reset button are also included. CEP7-EE enhanced model The enhanced CEP7-EE variant covers an operating range of. - 8A with adjustable trip class settings of, 5, 2 and 3 (via dip switch selection). The EE model can be further enhanced by the addition of side mounted plug-in modules. CEP7-E_P pass through model For current ranges - 27A a version is available that mounts separate from the contactor. The motor wires pass through CT openings. Superior phase failure protection Onboard electronics constantly monitors all motor phases. If the ASIC chip set senses that one or more of the phases is missing during a steady state operation of a fully loaded motor, it will trip in 3 seconds. If a single phase condition is present during starting, the CEP7 will trip within 8 seconds (for a motor loading of > 8 %). These trip times are significantly faster then conventional bimetal overloads. In addition, the CEP7 relay detects a 5 % phase imbalance in the same way as a phase loss. Rated up to V AC Complies to IEC-6997 for nominal operation voltage of volts. 27A 4

5 Modular in design, clever in application The new CEP7-EE overloads now offer a formidable range of smart add on modules. These small side mounted plug-in modules extend the CEP7 capability to something more potent in terms of motor protection. Communication modules are also available. CEP7-EE + EDN DeviceNet TM CEP7-ERPB CEP7-EDN CEP7-ETN CEP7-ERR CEP7-EJM CEP7-EPT CEP7-EGF CEP7-EGJ Profibus communication module DeviceNet TM communication module Ethernet / IP communication module Remote reset module Jam protection and remote reset module PTC thermistor relay and remote reset module Ground fault protection and remote reset module Ground fault / jam protection and remote reset module CEP7-ERID Remote indication module (works with any side module ) CEP7-EE + EPRB Profibus Electronic overload relays for 3 phase motor applications to IEC 6947 CEP7 ED/EE/E_P x x PRODUCT TYPE MODEL CURRENT RANGE OF SINGLE PHASE MOTORS CURRENT RANGE OF THREE PHASE MOTORS CODE TO SUIT CA7 / CA6 CONTACTORS CEP7 = 3 phase ED = Basic model 3) P =...5.A Rated Voltage 69V AC B = CA CEP7S = phase EE = Enhanced model R = A A =...5A D = CA EE_P = Enhanced pass through 2) S = A B =.2...A E = CA T = A C =...5.A F = CA U = 8...9A D = A G = CA E = A H = CA ) F = A Q =...55A G = 8...9A V = 6...2A Rated Voltage V AC H = 3...5A J = 4...2A K = 6...3A L =...5A M = 2...6A N = 6...8A ) Notes: Not compatible with communication modules 2) Only available in 3 Phase. Current range options available are C, D and E only. Rated to V AC with V rated insulation cables 3) Only available in 3 Phase. Current range options available are A, B, C, D, E and F only. 4) Rated up to 69V AC 5

6 CEP7-ED Standard Electronic Overload Relays Electronic overload relays for 3 phase motors to IEC 6947 Manual reset, trip class - standard. 45 amps 5 : current adjustment range Low power consumption Self powered Visible trip indicator N/C trip contact and N/O alarm contact Direct mounting to CA7 contactors up to CA7-97. Manual Reset Class Approx kw range Current Setting Range (Amps) To Suit Contactor Catalogue No CA7-9/2/6/23 CEP7-EDAB CA7-9/2/6/23 CEP7-EDBB CA7-9/2/6/23 CEP7-EDCB CA7-9/2/6/23 CEP7-EDDB CA7-9/2/6/23 CEP7-EDEB CA7-3/37/43/55 CEP7-EDFD Electronic overloads for single phase applications to IEC 6947 Same features as above plus: Optional jam / stall and ground fault protection module Selectable auto / manual reset. Single Phase Approx kw range Current Setting Range (Amps) To Suit Contactor Catalogue No CA7-9/2/6/23 CEP7S-EEPB CA7-9/2/6/23 CEP7S-EERB CA7-9/2/6/23 CEP7S-EESB CA7-3/37/43/55 CEP7S-EETD CA7-6/72/85/97 CEP7S-EEUE 6

7 Overview of CEP7-EE Features MOULDED POWER CONNECTORS CONTACTOR CONNECTING MECHANISM TEST BUTTON RESET BUTTON CEP7-EPRB MECHANICAL TRIP TEST DIP SWITCHES TRIP STATUS INDICATOR FLA SETTING DIAL CONTROL TERMINALS LOAD TERMINATIONS CEP7-EDN CEP7-ETN Communication options with add-on modules All CEP7-EE versions from. - 8A can be fitted with side accessories ( per overload). In the case of fieldbus communication side modules, they provide the possibility to control the contactor or collect inputs over the fieldbus network. Further, it then becomes possible to monitor trips, warnings and motor operating parameters. Profibus - CEP7-EPRB Supports DP-V and DP-V Auto-band up to 2 MB/s DeviceNet TM - CEP7-EDN Can also be stand alone programmed using CEP7-DNCT programmer Ethernet/IP - CEP7-ETN Built-in webserver support for configuration and monitoring All communication modules add the following features: Overload warning Jam trip and warning Overload warning 2 inputs output Diagnostics: - % thermal utilised - Average current % FLA - Device status - Trip and warn status 7

8 AUTO / MANUAL RESET CLASS, 5, 2 OR 3 CEP7-EEAB CEP7-EEGE CEP7-EE Enhanced Electronic Overload Relays ) Electronic overload relays for 3 phase motors to IEC 6947 Auto / manual reset, trip class, 5, 2 or 3 - enhanced. to 8 Amps 5 : current adjustment range Direct mounting to CA7 and CA6 contactors Self powered Low power consumption N/C trip contact and N/O alarm contact Visible trip indicator Selectable manual reset Adjustable trip class, 5, 2 and 3 Optional DeviceNet communication module Optional Profibus communication module Optional EtherNet / IP communication module Optional jam / stall and remote reset module Optional PTC thermistor relay and remote reset Optional ground fault protection and remote reset CEP7-EEJF CEP7-EEJG CEP7-EEMH Approx kw range Current Setting Range (Amps) To Suit Contactor Catalogue No. Rated Operation Voltage: 69 Volts AC CA7-9/2/6/23 CEP7-EEAB CA7-9/2/6/23 CEP7-EEBB CA7-9/2/6/23 CEP7-EECB CA7-9/2/6/23 CEP7-EEDB CA7-9/2/6/23 CEP7-EEEB CA7-3/37/43/55 CEP7-EEED CA7-3/37/43/55 CEP7-EEFD CA7-3/37/43/55 CEP7-EEQD CA7-6/72/85/97 CEP7-EEGE CA7-6/72/85/97 CEP7-EEVE Rated Operation Voltage: Volts AC CA6-5/4/8 CEP7-EEHF 22 2) 4 2 CA6-5/4/8 CEP7-EEJF CA6-2/25/3/42 CEP7-EEJG CA6-2/25/3/42 CEP7-EEKG CA6-2/25/3/42 CEP7-EELG CA6-63/86 CEP7-EEMH CA6-63/86 CEP7-EENH Notes: ) EE versions can be fitted with side mount accessories. Refer pages-. 8

9 CEP7-E_P Pass Through Electronic Overload Relays The CEP7-E_P versions provide additional application flexibility and are designed to be mounted separately from the contactor. The motor wires are simply passed through the CT openings in the device and straight to the contactor which reduces the number of connection points. This makes them ideal in retrofit applications and when used with contactors other than CA7 or where space is restricted. The P version can be fitted directly onto DIN rail to speed up assembly. The EE_P version can also accept any of the side mount accessories including the communication modules; DeviceNet TM, Profibus or Ethernet / IP. CEP7-EE_P Enhanced Model The pass through version of the CEP7 permits separate mount of the overload relay. Current Setting Range (Amps) Control Terminal Wire Variable Rated Operation Voltage: Volts AC ) Control Terminal Torque Variable Trip class Catalogue No mm 2.55 Nm -3 CEP7-EECP mm 2.55 Nm -3 CEP7-EEDP mm 2.55 Nm -3 CEP7-EEEP Motor load side cables simply pass through a window in the overload relay body. The internal current transformers monitor the current flow. Note: ) With V rated insulated cables 9

10 CEP7 Side Mount Modules ) Accessory Description To Suit Catalogue No. Remote Reset Module Provision for reset after trip from remote pilot device or CEP7-ERID CEP7(S)-EE CEP7-EE_P CEP7-ERR CEP7-ERR Jam Protection and Remote Reset Module Dip switch adjustable jam protection - Jam set points - 5%, 2%, 3%, or 4% FLA - Trip delay -.5,, 2, or 4 sec. Provision for reset after trip from remote pilot device or CEP7-ERID CEP7-EJM CEP7(S)-EE CEP7-EE_P CEP7- EJM PTC Thermistor Relay and Remote Reset Module PTC protection and LED status indication Type of control unit Mark A Number of sensors 6 Maximum cold resistance of sensor chain 5 Ω Trip resistance 34 Ω ± 5 Ω Reset resistance 6 Ω ± 5 Ω Short circuit trip resistance 25 Ω ± Ω Open circuit trip resistance > 2, Ω Maximum voltage at T / T2 (Rptc=4 k Ω) < 7.5V DC Maximum voltage at T / T2 (Rptc=open) < 3 V DC PTC response time 5 8 ms Provision for reset after trip from remote pilot device or CEP7-ERID CEP7-EPT CEP7(S)-EE CEP7-EE_P CEP7-EPT 2) 3) Ground Fault Protection and Remote Reset Module Dip switch adjustable ground fault protection > GF current range set points - 2 ma - 5mA -.2.A -. 5.A > GF trip level 2% - % LED status indication Provision for reset after trip from remote pilot device or CEP7-ERID Must use with CEP 7 - CBCT current sensor CEP7-EGF CEP7(S)-EE_ CEP7-EE_P CEP7-EGF 2) 3) Ground Fault/Jam Protection and Remote Reset Module Dip switch adjustable ground fault protection same as CEP7-EGF shown above Jam trip when the motor current exceeds 4% FLA setting when enabled LED status indication Provision for reset after trip from remote pilot device or CEP7-ERID Must use with CEP7 - CBCT current sensor CEP7-EGJ CEP7(S)-EE CEP7-EE_P CEP7-EGJ ) Notes: Side mount modules must have 24-24V, 47-63Hz or DC applied to terminals A and A2 for control power 2) Attention: The CEP7 overload relay is not a ground fault circuit interruptor for personnel protection 3) Must be used with core balance transformer refer page

11 CEP7-CBCT Core Balance Transformers for CEP7-EGF/EGJ Ground fault current is sensed by passing all lines carrying current to and from a motor through the window of a special core balance current transformer often called a toroid / ground fault sensor. If all the current to the motor returns through the lines in the toroid, no significant current will be induced in the toroid secondary. If, however, ground fault current returns via a path external to the toroid, such as via the conduit walls, a current will be induced in the toroid secondary. This current will be sensed and amplified by solid state circuits. If the ground fault current is larger than the selected ground fault trip level of the overload relay, the overload relay will trip. Sensor Type Approx. Current Rating Inside Diameter Max Rec. Cable 6V Typical Use with Contactor Size Catalogue No. 45A 9mm mm 2 ) CA CA7-43 CEP7-CBCT 9A 4mm 35mm 2 ) CA CA7-85 CEP7-CBCT2 8A 64mm 2mm 2 ) CA6-8 CEP7-CBCT3 42A 82mm 85mm 2 ) CA6-42 CEP7-CBCT4 86A 6mm 3mm 2 ) CA6-86 CEP7-CBCT5 Communication Modules Description To Suit Catalogue No. Ethernet / IP Communication Module Includes warning for jam trip, overload and underload Inputs/outputs - 2 inputs (24V DC rated) - output relay (B3 rated) - status indication LED Monitoring - % thermal utilised - average current % FLA - device, trip and warn status Profibus Communication Module Includes warning for jam trip, overload and underload Inputs/outputs - 2 inputs (24V DC rated) - output relay (B3 rated) - status indication LED Monitoring - % thermal utilised - average current % FLA - device, trip and warn status CEP7(S)-EE CEP7-EE_P CEP7(S)-EE CEP7-EE_P CEP7-ETN CEP7-EPRB DeviceNet Communication Module CEP7(S)-EE CEP7-EE_P CEP7-EDN DeviceNet Hand Held Programmer HMI 2) Programming terminal includes m communication cable To be used with CEP7-C/C2/C3 and CEP7-EDN module CEP7(S)-EE CEP7-EE_P CEP7-DNCT ) Notes: With a 3 phase system with one cable per phase 2) Can be used on any DeviceNet TM product or network. Compatible with CEP7C

12 Accessories Accessory Description For Use with Catalogue No. DIN-Rail / Panel Adaptor For separate mounting of overload relay to backpan or top hat DIN-rail CEP7-ED_B CEP7(S)-EE_B CEP7-EE D CEP7-EE E CEP7-EPB CEP7-EPD CEP7-EPE Current adjustment shield Prevents inadvertent adjustment of the current setting All CEP7 CEP7-BC8 External reset button adaptor Provides a larger target area for resetting the overload relay when using an external reset button All CEP 7 CEP 7-ERA External reset button Manual reset pushbutton used for resetting overloads mounted in enclosures. To be used with CEP7-ERA All CEP7 D7P-R6 Reset rod To suit D7 external reset pushbutton (D7P-R6) and CEP7-ERA adaptor All CEP7 D7-ATR8 Adjustment cover for external modules All CEP7 CEP7-EMC Remote reset solenoids 24V AC V AC 24V AC 24V DC 48V DC V DC All CEP7 All CEP7 All CEP7 All CEP7 All CEP7 All CEP7 CEP7-EMRJ CEP7-EMRD CEP7-EMRA CEP7-EMRZ24 CEP7-EMRZ48 CEP7-EMRZ metre communications cable with micro-connector CEP7-DNCT CEP7-CM metre communications cable with bare leads (included with the CEP7-DNCT) CEP7-DNCT CEP7-BC Door / panel mount bezel kit CEP7-DNCT CEP7-DNCT - BZ Remote indication and reset module ) Panel mounted IP66 uses 22.5mm fixing hole. It must be used in conjunction with a side mount module and connects via two wires to the remote reset terminals R and R2. Indication LEDS Power Overload Trip (solid) Warning (flash) Phase loss Module specific LED - ground fault, PTC, jam CEP7-ERR CEP7-EJM CEP7-EPT CEP7-EGF CEP7-EGJ CEP7-ERID Notes: ) Must be used with side mount modules. Not compatible with communication modules 2

13 Accessories DISPLAY STATUS Module power (GREEN, flash) Module power & motor current (GREEN, solid) Hardware fault (RED, solid Works with CEP7-EE Overloads from. to 8 Amps PHASE LOSS LED Trip (RED, solid) OVERLOAD CONDITIONS LED Trip (RED, solid) Warning (YELLOW, flash) Remote Reset MODULE FAULT LED Ground fault trip (RED, one flash) Jam trip (RED, two flashes) PTC trip (RED, three flashes) Fault detected (RED, rapid flash) IP66 rated Dimensions (mm) Installation 22mm hole Starter: FAULT CODE - GROUND FAULT 2- JAM 3- PTC mm hole Starter: FAULT CODE - GROUND FAULT 2- JAM 3- PTC N m (5-7 lb-in).6mm X 3.5mm Blade (.2 in X.4 in Blade) 46 7mm (.28 in) 3

14 CEP7-EE CEP7-EE CEP7 QUICK REFERENCE GUIDE Motor protection CEP7 overload relays NHP have introduced the new Sprecher + Schuh CEP7, second generation electronic overload protection relays. The new CEP7 overloads incorporate a greater use of sophisticated electronic control and monitoring. The CEP7 second generation overload now incorporates greater accuracy and versatility whilst providing increased overall protection. CURRENT SETTING RANGE (A) CEP7-EEJG CEP7-EEKG CEP7-EELG...5 CURRENT SETTING RANGE (A) CEP7-EEMH CEP7-EENH Amps kw CEP7 SIDE MOUNT MODULES CA6 ( VAC) CEP QUI REFER GUI Remote reset module CEP7-ERR CURRENT SETTING RANGE (A) CEP7-EEHF CEP7-EEJF kw Amps Jam protection and remote reset module CEP7-EJM PTC thermistor relay and remote reset module CEP7-EPT Ground fault protection and remote reset module CEP7-EGF Ground fault/jam protection and remote reset module CEP7-EGJ Profibus communication module CEP7-EPRB DeviceNet TM communication module CEP7-EDN Ethernet / IP communication module CEP7-ETN CEP7-EE

15 CK ENCE DE STANDARD ELECTRONIC OVERLOAD RELAYS FOR 3 PHASE MOTORS CURRENT SETTING RANGE (A) CEP7-EDAB...5 CEP7-EDBB.2... CEP7-EDCB CURRENT SETTING RANGE (A) CEP7-EEGE CEP7-EEVE CEP7-EDDB CEP7-EDEB ENHANCED ELECTRONIC OVERLOAD RELAYS FOR 3 PHASE MOTORS CA7 (69 VAC) CURRENT SETTING RANGE (A) CEP7-EEAB...5 CEP7-EEBB.2... CEP7-EECB...5. CEP7-EEDB CEP7-EEEB FEATURES: Auto/manual reset Adjustable trip class, 5, 2 and 3 5: current adjustment range Self powered Low power consumption Direct mounting to CA7 contactors N/C trip contact and N/O alarm contact Visible trip indicator Optional side mount modules CURRENT SETTING RANGE (A) CEP7-EEED CEP7-EEFD CEP7-EEQD...55 FEATURES: Manual reset Trip class 5: current adjustment range Self powered Low power consumption Direct mounting to CA7 contactors N/C trip contact and N/O alarm contact Visible trip indicator Electronic overloads also available for single phase applications to IEC Current settings from...9 amps. See page 6. Electronic overloads CEP7-E_P pass through version also available. See page 9. CEP 7-ED CEP 7-EE CEP7-EE CEP7-EE

16 Dimensions (mm) J H A F E G K B D C L CEP7 mounted to CA7 contactor (with side mounted module) Overload Catalogue No. Contactor Catalogue No. mm A B C D E F G H J K L CEP7*-EE_B CA7-9/2/6/ CEP7*-EE_D CA7-3/ CA7-43/ CEP7*-EE_E CA7-6/72/85/ CEP7 Module Technical Information Connect remote reset pilot device to terminals R and R2. Do not apply external voltage to R and R2. Equipment damage will occur. Recommend use of twisted pair for remote reset,.2 mm 2 minimum. Apply 24-24V, 47-63Hz or DC to terminals A and A2 for control power. Rated insulation voltage (Ui) 3V Rated operating voltage (Ue) 24-24V AC, 5/6Hz 24-24V DC Power at rated operating voltage 24V AC.3W (Typical) 2V AC.3W 24V AC.5W Rated impulse withstand voltage (U imp) 2.5kV Dynamic inhibit on start. A unique circuit within the CEP7 protection modules monitors for motor starting inrush current. The circuit inhibits the protection feature during the motor start period and arms the protection function after the inrush current falls to motor rated current. This allows the motor to start and run, avoiding nuisance tripping during the inrush period Wire size and torque specifications X 2X X 2X X 2X mm mm 2.55 Nm mm mm 2.55 Nm mm mm 2.55 Nm Notes: * No letter indicates 3 phase; S indicates single phase 6

17 Dimensions (mm) CA6-] Ø 5.6 RESET BUTTON TRAVEL: CEP7-EEVF mounted to CA6 Contactor CEP7-EE_F...EE_H Mounted To CA6 Contactor Overload Catalogue No. Contactor Catalogue No. A Width b Height B C Depth D E E2 F G H J K M Without terminal covers With terminal covers Reset CA6-5 (EI) CEP7-EE_F CEP7-EE_G CEP7-EE_H CA6-4 (EI) CA6-8 (EI) CA6-2 EI CA6-42 EI CA6-63 EI CA6-86 EI CEP7 pass through overload 7

18 Wiring Diagrams CEP7-ERR and CEP7-EJM CEP7-ERR and CEP7-EJM Wiring Diagrams R2 R A2 A R2 R R A2 Apply 24-24V, 47-63Hz or DC to terminals A and A2 for control power. Connect remote reset pilot device or CEP7- ERID to terminals R and R2. CEP7-EPT R2 R Apply 24-24V, 47-63Hz or DC to terminals A and A2 for control power. Connect remote reset pilot device or CEP7-ERID to terminals R and R2. Connect terminal IT and IT2 to PTC chain. A2 A CEP7-EPT Wiring Diagrams A R2 A2 A CEP7-ERR Dip Switch Adjustment Settings Overload Relay Reset Mode SW Manual: I Automatic: Overload Relay Type SW2 3 Phase: I Phase: A2 Adjustment Settings SW3 Not Used Remote Reset A SW Enable: I Disable: STATUS LED Jam Protection Steady green - Module is powered up. SW2 Enable: Jam Trip Level SW 3 SW 4 5% 2% I 3% I 4% I I Jam Protection Adjustment SW2 Enable: Settings Disable: I Overload Relay Reset Mode SW Manual: Jam Trip I Level Automatic: Jam Trip Delay SW 3 SW 4 5% SW 2 SW 3 SW 4. sec 2% I.5 sec sec 3% I 2 sec 3 sec 4% I I 4 sec Jam Trip Delay 5 sec SW 5 SW 6 sec.5 sec I I Jam Trip Level sec I SW 5 SW 6 SW 7 Disable / OFF 2 sec % FLA 4 sec I 25% FLA 5% FLA 2% FLA 3% FLA 4% FLA 6% FLA SW8 3 Phase: I Phase: CEP7-EPT Wiring Diagram CEP7-EPT Operational LED CEP7-EPT Dip Switch R2 STATUS LED IT Adjustment Settings ) Steady green - Module is powered IT2 up. Overload Relay and PTC Reset Mode R Flashing LED - The number of flashes SW Manual: I Automatic: followed by a pause identifies A2 the specific R2 trip code as follows: PTC Protection IT Adjustment Settings ) SW2 Enable: I Disable: IT2 () Flash - overload trip Overload Relay and PTC Reset Mode A (2) Flash - phase loss trip Overload Relay Type SW Manual: I Automatic: A2 SW3 3 Phase: I Phase: (3) Flash PTC - Protection PTC trip SW2 (4) Flash Enable: - PTC I open Disable: circuit A (5) Flash Overload - PTC Relay short Type circuit SW3 3 Phase: I Phase: Fast flash - Impending trip. PTC thermistor fault detected and CEP 7 not yet capable of tripping. R2 R IT2 IT A2 A R2 R A2 A Disable: I Jam Trip Delay SW 5 SW 6 CEP7-EPT Wiring Diagrams.5 sec I I R2 R IT2 IT sec I 2 sec I 4 sec A2 A R Steady red - Hardware fault. Internal hardware fault detected and CEP 7 trip attempted. CEP7-EJM Dip Switch Notes: ) The delay between the occurrence of a PTC out-of-range fault and a trip of the CEP 7 varies, but is generally described by one of the following: 5 ms ± 25 ms, typical; - < 6 seconds, for a PTC out-of-range fault present at power-up of the side mount module. - Under no conditions should a PTC trip take longer than 6 seconds. R2 R Adjustment Settings Remote Reset SW Enable: I Disable: 8

19 Wiring Diagrams CEP7-EGF and CEP7-EGJ CEP7-EGF and CEP7-EGJ Wiring Diagrams R2 R S2 S A2 A Apply 24-24V, 47-63Hz or DC to terminals A and A2 for control power. Connect remote reset pilot device or CEP7-ERID to terminals R and R2. Connect current sensor to terminal S and S2. S2 S CEP7-EGF and CEP7-EGJ A2 A R2 R CEP7-EGF Operational LED STATUS LED Steady green - Module is powered up. Flashing LED - The number of flashes followed by a pause identifies the specific trip code as follows: () Flash - overload trip (2) Flash - phase loss trip (3) Flash - ground fault trip Fast flash - Impending trip ground fault detected and CEP7 not yet capable of tripping. Steady red - Hardware fault. Internal hardware fault detected and CEP7 trip attempted. CEP7-EGF Dip Switch Adjustment Settings Overload Relay Reset Mode SW Manual: I Automatic: Ground Fault Current Range SW 2 SW m A...5 ma I.2... A I...5. A I I Ground Fault Trip Level SW 4 SW 5 SW 6 Disable/Off 2 % Max GF Current I 35 % Max GF Current 5 % Max GF Current I I I 65 % Max GF Current I 8 % Max GF Current 9 % Max GF Current % Max GF Current I I I I I I I CEP7-EGF and CEP7-EGJ Installation CEP7-EGJ Operational LED CEP7-EGJ Dip Switch STATUS LED Adjustment Settings Ground Fault Sensor (CEP7-CBCT_) Overload Relay Reset Mode Control Wiring Steady green - Module is powered up. SW Manual: I L L2 L3 Flashing LED - The number of flashes Ground Fault Current Range followed by a pause identifies the specific SW 2 trip code as follows: 2... ma Ground...5 ma () Flash - overload trip Fault.2... A Sensor (2) Flash - phase loss trip (3) Flash - ground fault trip...5. A Ground Fault Trip Level SW 5 Fast flash - Impending trip ground fault detected and CEP7 not yet capable of S S2 tripping. I I Steady red - Hardware fault. Internal hardware fault detected and CEP7 trip attempted. Motor CEP7 Overload Relay with Side Mount Module SW7 SW8 Disable/Off 2 % Max GF Curren t 35 % Max GF Curren t 5 % Max GF Curren t 65 % Max GF Curren t 8 % Max GF Curren t 9 % Max GF Current % Max GF Current SW7 SW8 Overload Relay Type 3 Phase: I Phase: Not Used Automatic: SW3 I I I I SW 4 SW 6 I I I I I I I I I I Overload Relay Type 3 Phase: I Phase: Jam Protection Enable: I Disable: 9

20 Wiring Diagrams CEP7-ERR and CEP7-EJM CEP7-EDN DeviceNet TM Module CEP7-EPRB Profibus Module CEP7-ETN Ethernet / IP Module 2

21 CEP7-ETN Ethernet Network Communication Module Connects to the network via RJ45 (Cat 5) connector. Supports I/O and explicit messaging for data access by programmable automatic controller. Contains predefined ControlLogix style tags for direct software access. Includes an integrated web server to allow users to read information and configure parameters via a computer web browser from remote locations. Uses a Simple Mail Transfer Protocol (SMTP) server to send or text messages in the event of a warning or trip condition. Ethernet /IP Communications TCP Connection 5 Explicit Packet Rates 5/s CIP Connection 48 Speed Duplex (Half/Full) / CIP Unconnected Messages 28 Duplicate IP Detection Yes I/O Packet Rates 5/s Offers Integrated Web and Server View the status and events of your overload relay on the web at anytime, anywhere! The CEP7-ETN contains a web server to allow users to read information and configure parameters via the web. Uses a simple mail transfer protocol (SMTP) server to send or text messages in the event of a warning or trip condition. Electrical Power Supply Ratings Rated Supply Voltage 24V DC Rated Operation Range V DC Rated Supply Current.A Maximum Surge Current at Power-up 2.5A Maximum Power Consumption W Output Relay Ratings Terminal OUT A 3/4 Type of Contacts Form A SPST-NO Rated Thermal Current 5A Rated Insulation Voltage 3V AC Rated Operating Voltage 24V AC 3A (@ 2V AC) Rated Operating Current.5A (@ 24V AC).25A (@ V DC).A (@ 22V DC) Minimum Operating Current ma (@ 5V DC) Rating Designation B3 Utilization Category AC -5 Resistive Load Rating (p.f..) 5A, 25V DC 5A, 3V DC Inductive Load Rating (p.f. =.4), (L/R = 7 ms) 2A, 25V AC 2 A, 3V DC Short Circuit Current Rating A Recommended Control Circuit Fuse KTK-R-6 (6A, 6V) 2

22 CEP7-CBCT Core balance transformers Control wiring installation CEP7-CBCT ground fault trip data The control wiring must be a twisted pair Lines in excess of one metre long must be a shielded pair with the shield connected to ground at only one point Important: the shield, if present, of the twisted pair must be connected to earth ground at the sensor, with no connection made at the overload relay Maximum length is 3 metres for the shielded cable Sensor fastener torque Nm CEP7-CBCT lead wires should be twisted before termination by applying one twist per inch CEP7 overload relay with CEP7-EGF or CEP7-EGJ (CEP7-EE) L L2 L3 S S2 Motor Attention: the ground fault protection system is intended for equipment use only. This system is not a ground fault circuit interrupter for personnel protection. Ground fault trip delay The delay between the occurrence of a ground fault and a trip of the CEP7 varies, but is generally described by one of the following: < 6 seconds, for a ground fault present at power up of the side mount module < 3 seconds, if the protection inhibit has not been cleared. Under no conditions should a ground fault trip take longer than 3 seconds 22

23 Power cable installation All power cables, including the neutral when used, must pass through the sensor window. The equipment ground conductor (the conductor used to carry the non-current carrying metal parts of equipment) must not pass through the sensor window. 2 The power cables, going through the sensor window, must be straight, tightly bundled, centred in the window, and perpendicular to the sensor for a length equal to or greater than six times the cable bundle diameter (including insulation) from the sensor (see Figure ). 3 All other conductors with available fault currents in excess of, A should be placed a distance equal to or greater than six times the cable bundle diameter (including insulation) from the sensor (see Figure 2). 4 The power cables of the branch circuit, to be protected by the overload relay, must not be grounded on the load side of the ground fault sensor. 5 If the power cables are enclosed in a conducting jacket, the jacket must be grounded on the line side of the sensor. The jacket must not pass through the sensor window, but must be cut at the window and joined with a conductor that passes outside the sensor window. 6 The power system must be solidly grounded or grounded through an impedance at the source, as long as the impedance allows for a magnitude of current to flow that is within the operational range of the overload relay. CEP7 overload relay with CEP7-EGF or CEP7-EGJ (CEP7-EE) Figure Figure 2 Attention: To prevent electrical shock, disconnect from power source before installing or servicing. Install in a suitable enclosure, keep free from contaminants. Do not apply power to a system with power cables going through the sensor unless the sensor is connected to the overload relay. Operation without a low impedence connection to the secondary windings may result in damage to the sensor. 23

24 Locating phase conductors in the sensor window Firmly secure the conductors in the centre of the sensor window so that they cannot be moved accidentally or under fault conditions Maintain as large a distance as possible between the bundled conductors and the wall of the sensor window For applications having one cable per phase, arrange the conductors per Figure A For applications having two cables per phase, arrange the conductors per Figure B. A spacer, having the same diameter as the conductors being used, should be used to separate the phase conductors Single cable per phase Two cables per phase A B C C B A A B C spacer Figure A Figure B Attention: The ground fault protection system is intended for equipment use only. This system is not a ground fault circuit interrupter for personnel protection. An ideal core-balanced ground fault toroid responds only to the sum of the currents flowing through the sensor window, however, an actual core balanced transformer may saturate if the phase currents are too large. This results in ground fault sensor output even if the sum of the phase currents is zero. Saturation can be minimised by choosing a ground fault sensor with adequate core size and symmetrically locating the phase conductors in the centre of the sensor window as shown above. 24

25 Dimensions (mm) CEP7-CBCT Ø Ø CEP7-CBCT 2 and 3 E.8 A 44.5 C 3.2 Ø D 5.3 F B Dimensions (mm) Catalogue No. A B C Ø D E F CEP7-CBCT CEP7-CBCT CEP7-CBCT

26 Trip curves ) TRIP CLASS TRIP CLASS 5 Time (seconds) Time (seconds). FLA multiple. FLA multiple TRIP CLASS 2 TRIP CLASS 3 Time (seconds) Time (seconds). FLA multiple. FLA multiple Cold trip Hot trip Notes: ) Typical reset time for CEP7 devices set to automatic reset mode is 2 seconds. Technical information Electromagnetic Compatibility Test Level Performance Level Electrostatic discharge immunity [kv] 8 kv air discharge, 6kV contact discharge ) 2 ) RF Immunity [V/m] V/m, ) 2 ) Electrical fast transient burst immunity [V/m] 4 kv, ) 2 ) Surge Immunity [V/m] 2 kv (L-E), kv (L-L), ) 2 ) General Standards UL, 58, CSA C22.2 No. 4, NEMA (CD2-993 Part 4, EN , EN ) Approvals CE, C-Tick, CSA, UL, Atex (pending) 26

27 Technical information Control Circuit Rated insulation voltage - U I [V] 69 AC Rated insulation strength - U imp [kv] 6 AC Rated operation voltage - U e [V] 69 AC (IEC) / 69 AC (UL/CSA) Rated operation current - U e 2...2V [A] 3/2 ) V [A].5 /.5 AC V [A].75 / V [A].6 /.6 24V [A] DC-3 V [A] at L/R 5 ms 22V [A] 44V [A] Thermal current - I the Contact reliability Screw terminal cross section Terminal screw [A] [kv] One conductor [mm 2 ] Flexible with wire Torque [Nm] end ferrule Two conductors [mm 2 ] Torque [Nm] One conductor [mm 2 ] Course stranded Torque [Nm] / solid Two conductors [mm 2 ] Torque [Nm] One conductor [mm 2 ] Stranded Torque [Nm] / solid Two conductors [mm 2 ] Torque [Nm]. /..4 /.4.2 /.2.8 / V, 5mA M3 x ( ).55 2 x ( ).55 x (.5...4).55 2 x ( ).55 x ( ).55 2 x ( ).55 Pozidrive screwdriver size Slotted screwdriver size [mm].6 x 3.5 Environmental Ratings Ambient temperature Storage [ C] Operating [ C] Humidity Operating [%] , non-condensing Damp Heat per IEC and IEC Vibration (per IEC ) [G] 3 Shock (per IEC ) [G] 3 Maximum altitude [m] 2 Pollution environment Pollution degree 3 Degree of protection IP2 Type of relay Ambient compensated, time delay, phase loss standard Nature of relay Solid state Trip rating Trip class Reset mode Type ED Type EE Type ED Type EE Notes: ) Performance criteria requires the DUT to experience no degradation or loss of performance 2) Environment 2 2 % FLA, 5, 2, 3 Manual Manual or automatic 27

28 For more information, scan to download the NHP ecatalogues App offering exclusive video content, catalogues and literature! AUSTRALIA nhp.com.au SALES 3 NHP NHP FAX 3 NHP FAX NEW SOUTH WALES Sydney 3-34 Day Street North Silverwater NSW 228 Tel QUEENSLAND Brisbane 6 Riverview Place Murarrie QLD 472 Tel NEW ZEALAND nhp-nz.com SALES 8 NHP NHP FAX 8 FAX NHP VICTORIA Melbourne River Street Richmond VIC 32 Tel Laverton 4-6 William Angliss Drive Laverton North VIC 326 Tel Albury / Wodonga 847 Ramsden Drive Albury NSW 264 Tel Fax Dandenong Unit /8 Monash Drive Dandenong South VIC 375 Tel Fax TASMANIA Hobart 29B Lampton Ave Derwent Park TAS 79 Tel Fax Launceston Unit Merino Street Kings Meadows TAS 7249 Tel Fax Newcastle 575 Maitland Road Mayfield West NSW 234 Tel Fax Wollongong Unit 3 Resolution Drive Unanderra NSW 2526 Tel Fax ACT Canberra Unit 87 Gladstone Street Fyshwick ACT 269 Tel Fax WESTERN AUSTRALIA Perth 38 Belmont Ave Rivervale WA 63 Tel NORTHERN TERRITORY Darwin 3 Steele Street Winnellie NT 82 Tel Fax Townsville 5 Leyland Street Garbutt QLD 484 Tel Fax Rockhampton Lawson Street Parkhurst QLD 472 Tel Fax Toowoomba Cnr Carroll Street and Struan Court QLD 435 Tel Fax Cairns Unit 2 Bramp Close Portsmith QLD 487 Tel Fax SOUTH AUSTRALIA Adelaide Croydon Road Keswick SA 535 Tel PO Box 62-9 Sylvia Park Auckland 644 New Zealand Auckland 8a Carbine Road Mt Wellington 6 Hamilton 78 Rostrevor Street Hamilton 324 Napier 26 Taradale Road Onekawa 4 New Plymouth 2 Dean Place Waiwhakaiho 432 Wellington Unit B4, 59 Marsden Street Melling Lower Hutt 5 Christchurch 27 Iversen Terrace Waltham 8 Dunedin 3 Fox Street South Dunedin 92 NHP Electrical Engineering Products Pty Ltd A.B.N NSPRECHCEP7C 2/6 Copyright NHP 26

Energy Monitoring and Control System

Energy Monitoring and Control System Energy Monitoring and Control System Local and multi-site energy management solutions ENERGY MANAGEMENT AND BUILDING AUTOMATION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300 NHP NHP 0800 NHP

More information

POWER FACTOR CORRECTION

POWER FACTOR CORRECTION [CATALOGUE PFC-SFC] POWER FACTOR CORRECTION INDUSTRIAL SWITCHGEAR & AUTOMATION SPECIALISTS A component of nhp s green star solution... www.nhp.com.au Power Factor - What does it mean? Where open electricity

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

ESA operator panels & industrial PCs

ESA operator panels & industrial PCs ESA operator panels & industrial PCs Innovative and elegant design combined with state of the art technology AUTOMATION SYSTEMS NHP Electrical Engineering Products Pty Ltd Sales 1300 NHP NHP Sales 0800

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Bimetallic Overload Relay Specifications

Bimetallic Overload Relay Specifications Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Iboco Cable Ducting. An integrated system of wiring duct and accessories to suit all applications. TERMINATION & WIRING SYSTEMS

Iboco Cable Ducting. An integrated system of wiring duct and accessories to suit all applications. TERMINATION & WIRING SYSTEMS Iboco Cable Ducting An integrated system of wiring duct and accessories to suit all applications. TERMINATION & WIRING SYSTEMS NHP Electrical Engineering Products Pty Ltd Sales 1300 NHP NHP Sales 00 NHP

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

Install the DeviceNet Module using the following procedure:

Install the DeviceNet Module using the following procedure: Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

S-series SQ Controller

S-series SQ Controller DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced

More information

Provides one channel for Ethernet over existing

Provides one channel for Ethernet over existing LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information