DVM. Digital Power Meter DVM. Features. Technical Data. Typical Application Diagram. Case Dimensions. Ordering Information. Front. Panel Cutout.

Size: px
Start display at page:

Download "DVM. Digital Power Meter DVM. Features. Technical Data. Typical Application Diagram. Case Dimensions. Ordering Information. Front. Panel Cutout."

Transcription

1 Digital Power Meter DVM Built-in selector switch Easy-to-read, 14.2mm digit display DIN size casing Technical Data Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V AC VA rating : 3 VA Input frequency : 47 ~ 66 Hz Maximum input voltage : 500 Vrms Approximate weight : 0.6 kg Typical Application Diagram DVM360 Series DVM100 Series L N N Aux Supply AC 240 V Aux Supply AC 240 V 91.5 mm 87 mm 91.0 ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm DVM DVM A DVM A DVM A DVM A

2 DAM Typical Application Diagram 1 DAM330 / 3000 Series Aux Supply AC 240 V 6 Built-in selector switch Easy-to-read, 14.2mm digit display DIN size casing Wide selection of current transformer (CT) ratio Technical Data Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V AC VA rating : 3 VA Input frequency : 47 ~ 66 Hz Maximum input : 6 A continuous Ammeter CT ratio :.../5 A Class : 1.0 Approximate weight : 0.7 kg L N 91.5 mm 87 mm 1 DAM100 / 1000 Series Aux Supply AC 240 V ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm Digital Power Meter DAM

3 Digital Power Meter DAM For primary current from 60 A to 500 A DAM XXXX DAM XXXX Order number Model DAM 330 & DAM 100 ORDER NUMBER *CT RATIO / 5 A / 5 A / 5 A / 5 A 250 / 5 A 300 / 5 A 400 / 5 A 500 / 5 A Example: Model DAM for digital ammeter with CT ratio 60 / 5 A. *CT : / SERIES DAM330 DAM3000 DAM100 DAM1000 Current Transformer For other CT ratio, please contact the manufacturer. DAM330 - xxxx - 240A DAM100 - xxxx - 240A DAM330 - xxxx - 110A DAM100 - xxxx - 110A DAM xxxx - 240A DAM xxxx - 240A DAM xxxx - 110A DAM xxxx - 110A WITH SELECTOR WITHOUT SELECTOR For primary current from 600 A to 5000 A DAM XXXX DAM XXXX DISPLAY FORMAT 600 Order number Model DAM3000 & DAM1000 ORDER NUMBER *CT RATIO 600 / 5 A / 5 A / 5 A UNIT A A A A 1200 / 5 A 1500 / 5 A 1600 / 5 A 2000 / 5 A 2400 / 5 A / 5 A / 5 A / 5 A / 5 A / 5 A / 5 A / 5 A

4 DPM680 Measurement Parameters: Phase & Line Voltages (L-N) Phase Current & Neutral Current Bidirectional kw, kvar & kva Bidirectional kwh, kvarh & kvah Frequency Total & Displacement Power Factor Voltage Total Harmonic Distortion Current Total Harmonic Distortion Thermal Current Demand Power Demand Current Sequence Components Voltage Sequence Components Digital Power Meter TFT Colour LCD Display Serial RS-485 Modbus RTU Modbus TCP/IP Built-in Webserver Voltage & Current Waveform Display Voltage & Current Harmonics Display Technical Data WIRING SYSTEMS 3-phase 4-wire system 3-phase 3-wire system CURRENT MEASUREMENT (TRMS) Nominal current : 5 A Min. measurement : 5 ma : 0.2% of full scale Burden : < 0.05 VA at 5 A Measurement range : 10 A Pulsed withstand : 100 A for 1 sec CT primary : 5 ~ 50,000 A VOLTAGE MEASUREMENT (TRMS) Nominal phase voltage : 0 ~ 300 V AC Minimum measurement : 10 V : 0.2% at full scale Phase voltage via VT : 60 ~ 50,000 V POWER MEASUREMENT Real power, apparent power, reactive power : 0.5% POWER FACTOR MEASUREMENT Total and displacement power factor : 0.5% POWER & THERMAL CURRENT DEMAND Interval : 1 ~ 30 mins VOLTAGE AND CURRENT SEQUENCE COMPONENTS Positive, negative and zero sequence FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz : 0.2% ENERGY MEASUREMENT ACCURACY Active : IEC class 0.5 Reactive : IEC class 2 HARMONICS DISPLAY Fundamental up to 32nd order VOLTAGE & CURRENT WAVEFORM DISPLAY Simultaneous 3-phase voltage or current waveforms COMMUNICATION Interface : Modbus RTU : Isolated RS485 Interface Interface : Modbus TCP/IP : Ethernet 10M/100M BaseT : HTTP Server : Ethernet 10M/100M BaseT AUXILIARY POWER SUPPLY AC voltage : 90 ~ 415 V AC Frequency : 50 / 60 Hz DC voltage : 100 ~ 300 V DC Power consumption : 3W typical Sustained overload : 500 V AC ENVIRONMENTAL CONDITIONS Overvoltage category : IV Pollution degree : 2 Operating temperature : -10 C ~ +55 C Storage temperature : -20 C ~ +70 C Humidity : 0 95%, non condensing MECHANICAL Mounting : according to DIN / ANSI C39.1 Dimension (mm) : 96(w) x 96(h) x 100(d) Enclosure protection : IP63 at the panel IP20 at the body Approximate weight : 0.5 kg DPM 680

5 Digital Power Meter Typical Application Diagrams 3-PHASE 4-WIRE SYSTEM : 4 CTs, Direct V Input AUX 100~300 V DC l2 Ethernet 3-PHASE 4-WIRE SYSTEM : 3 CTs, Direct V Input AUX 100~300 V DC l2 Ethernet 90 mm 3-PHASE 3-WIRE SYSTEM : 3 CTs, 3 VTs 3-PHASE 3-WIRE SYSTEM : 3 CTs, Direct V Input 83 mm AUX 100~300 V DC l2 Ethernet AUX 100~300 V DC l2 Ethernet 17 mm Rear 100 mm 86 mm Test Standards Cut-Out Recommendations IEC Safety requirements. IEC EMC requirements. 91±0.5mm 91±0.5mm 101.6±0.5mm DPM 680 DPM AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC

6 Technical Data DISPLAY TYPE LCD display MEASUREMENTS 3-phase 4-wire system 3-phase 3-wire system CURRENT MEASUREMENT (TRMS) CT primary : 5 ~ 8000 A CT secondary : 5 A Minimum measurement : 5 ma : 0.5% from 1A to 6 A (secondary) Burden : < 0.05 VA at 5 A Sustained overload : 6 A VOLTAGE MEASUREMENT (TRMS) Nominal phase voltage : 20 ~ 300 V AC Minimum measurement : 10 V : 0.5% at full scale Phase voltage via VT : 60 ~ 33,000 V DPM380 DPM380B POWER MEASUREMENT Real power, apparent power, reactive power measurement Measuring updating period : 1 s : 1.0% ACTIVE POWER DEMAND Interval : 1 ~ 30 mins POWER FACTOR MEASUREMENT Total and displacement power factor : 1.0% FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz Measurement updating period : 1s : 0.5% ENERGY ACCURACY Active (according to IEC ) : class 1 Reactive (according to IEC ) : class 2 LCD display with back lighting communication (for DPM380 only) MEASUREMENT PARAMETERS: Phase Voltage (L-N) Line Voltage (L-L) Phase Current and Neutral Current Bidirectional kw (per phase & total) Bidirectional kvar (per phase & total) Bidirectional kva (per phase & total) Frequency Power Factor (per phase & total) Energy (+ and - ) for kwh, kvarh and kvah THD Phase Voltage ( L-N ) THD Phase Current Active Power Demand AUXILIARY POWER SUPPLY AC voltage : 90 ~ 415 V AC Frequency : 50 / 60 Hz DC voltage : 100 ~ 300 V DC Power consumption : <3 VA COMMUNICATION Hardware interface : Isolated RS485 : Baud rate : 2400, 4800, 9600, 19200, ENVIRONMENTAL CONDITIONS Operating temperature : -10 C ~ +55 C Storage temperature : -20 C ~ +70 C Humidity : 0 95%, non condensing MECHANICAL Mounting Dimension (mm) Approximate weight : Panel mounting : 96(w) x 96(h) x 100(d) : 0.5 kg Digital Power Meter DPM 380 / 380B

7 3-PHASE 4-WIRE SYSTEM WITH 4 CTs CONNECTION AUX 100~300 V DC l2 * For DPM380 only + 90 mm Digital Power Meter Typical Application Diagram 83 mm 10 0m m 17 mm 3-PHASE 4-WIRE SYSTEM WITH 3 CTs CONNECTION Rear ea AUX 100~300 V DC 86 mm 86 mm l2 * For DPM380 only - Cut-Out Recommendations + 91±0.5mm Electromagnetic Compatibility (EMC) 91±0.5mm DPM 380 / 380B Part 6-2: Generic Standards IEC Immunity for industrial environments. Part 6-4: Generic Standards IEC Emission standard for industrial environments. DPM AD DPM 380B-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC, with Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC 101.6±0.5mm

8 Technical Data DISPLAY TYPE LCD display MEASUREMENTS 3-phase 4-wire system CURRENT MEASUREMENT (TRMS) CT primary : 5 ~ 8000 A CT secondary : 5 A Minimum measurement : 10 ma : 0.5% from 1A to 6 A (secondary) Burden : < 0.03 VA at 5 A Sustained overload : 6 A VOLTAGE MEASUREMENT (TRMS) Nominal phase voltage : 70 ~ 300 V AC Minimum measurement : 10 V : 0.5% at full scale DM38 POWER MEASUREMENT Real power, apparent power, reactive power measurement Measuring updating period : 1 s : 1.0% POWER FACTOR MEASUREMENT Total and displacement power factor : 1.0% LCD display with back lighting communication DIN rail type MEASUREMENT PARAMETERS: Phase Voltage ( L-N ) Line Voltage ( L-L ) Phase Current Bidirectional kw (per phase & total) Bidirectional kvar (per phase & total) Bidirectional kva (per phase & total) Frequency FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz Measurement updating period : 1s : 0.5% ENERGY ACCURACY Active (according to IEC ) : class 1 Reactive (according to IEC ) : class 2 Power Factor (per phase & total) Energy (+ and - ) for kwh, kvarh and kvah THD Phase Voltage ( L-N ) THD Phase Current POWER SUPPLY Self supplied Frequency Power consumption : 100 ~ 240 V AC : 50 / 60 Hz : <3 VA COMMUNICATION Hardware interface : Isolated RS485 : Baud rate : 2400, 4800, 9600, 19200, ENVIRONMENTAL CONDITIONS Operating temperature : -10 C ~ +55 C Storage temperature : -20 C ~ +70 C Humidity : 0 95%, non condensing MECHANICAL Mounting Dimension (mm) Approximate weight : DIN rail : 65(w) x 85(h) x 50(d) : 0.3 kg Digital Power Meter DM 38

9 Digital Power Meter Typical Application Diagram DM 38 CONNECTION DIAGRAM I1 I2 I Ohm ! P1 P2 X DM38 NOTE: Current transformer secondary terminal MUST NOT be earthed. Electromagnetic Compatibility (EMC) Part 6-2: Generic Standards IEC Immunity for industrial environments. Part 6-4: Generic Standards IEC Emission standard for industrial environments. 65 mm 45.5 mm 85 mm DM A Self Powered 100~240 V AC 71 mm 50 mm DM mm

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Energy Management Power Analyzer Type WM14-96 Basic Version

Energy Management Power Analyzer Type WM14-96 Basic Version Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

M2M The measure of efficiency

M2M The measure of efficiency M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Multilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.

Multilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications. GE Grid Solutions Multilin EPM 6000 High Accuracy Power & Energy Measurement The Multilin EPM 6000 is one of the industry s highest performance revenue grade panel meters with superior cost to performance

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Metering Devices IQ Analyzer 6400/6600 Series

Metering Devices IQ Analyzer 6400/6600 Series Metering Devices IQ Analyzer 6400/6600 Series Technical Data Supersedes TD.17.02A.T.E pages 1-8 dated May 2000 Description Page General Description............................................. 2 Applications....................................................

More information

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering Metering devices Current grid values of your power distribution system at a glance at all times. Multifunctional metering devices by EFEN have an important share in improving energy efficiency and system

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7 Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

EARTH LEAKAGE PROTECTION: CONTENTS

EARTH LEAKAGE PROTECTION: CONTENTS EARTH LEAKAGE PROTECTION: CONTENTS Earth Leakage Relays 128-130 Trip Circuit Supervision Relays 128-130 TEMPROTECT Protection and Distribution 1A to 6300A page 127 EARTH LEAKAGE PROTECTION ELR-1E The ELR-1E

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

EM-PQ 1500 Power Quality Monitor. Operating Manual

EM-PQ 1500 Power Quality Monitor. Operating Manual EM-PQ 1500 Power Quality Monitor Operating Manual 1 User notes: 2 Contents Page Page 1. Quick start... 5 2. Description... 6 2.1 Operating principle... 6 3. Installation... 8 3.1 Mounting... 8 3.2 Electrical

More information

One Meter Works for Both Energy Saving and Power Quality Surveillance

One Meter Works for Both Energy Saving and Power Quality Surveillance Multi-Function Meter Eco-POWER METER W9M SERIES Conforming to ow Voltage and EMC Directives One Meter Works for Both Energy Saving and Quality Surveillance High accuracy: 0.2 %* Harmonic measurement* Simple

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

www.electroind.com. March 15th 2005 EI Solutions - Submetering 1

www.electroind.com. March 15th 2005 EI Solutions - Submetering 1 . March 15th 2005 EI Solutions - Submetering 1 What is Submetering? Electric Service Master Meter Utility Owned POCC Utility Billing Point Sub Meter Electric Distribution Sub Meter Sub Meter Sub Meter

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

FREJA 300 Relay Testing System

FREJA 300 Relay Testing System Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Counter for Energy. We make energy measurable and secure your future. www.g-mw.de

Counter for Energy. We make energy measurable and secure your future. www.g-mw.de Counter for Energy We make energy measurable and secure your future www.g-mw.de 10 reasons for GMW Customer oriented solutions Individual consultancy Satisfied customers in all continents Large range of

More information

Communicate and view data from meters with one simple device

Communicate and view data from meters with one simple device Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Elster Metering Systems. EC Directive 2004/22/EC

Elster Metering Systems. EC Directive 2004/22/EC EC Type Examination Certificate Number: UK/ 0120/ SGS0010 Elster Metering Systems Instrument Identification: A1100, Electricity Meter, LB********* Poly Phase, Credit, Active Import/ Export, Multi-rate,

More information

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

DIRIS A40/A41 RS485 JBUS/MODBUS. Operating instructions F GB D I NL E P

DIRIS A40/A41 RS485 JBUS/MODBUS. Operating instructions F GB D I NL E P DIRIS A40/A41 RS485 JBUS/MODBUS Operating instructions F GB D I NL E P COM DIRIS A40/A41 - Ref.: 536 103 A GB GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 4 INSTALLATION 5 CONNECTION 5 PROGRAMMING

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

Digital Clamp-on DMMs with uncompromising performance

Digital Clamp-on DMMs with uncompromising performance Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy

More information

Electrical Measuring Instruments

Electrical Measuring Instruments Electrical Measuring Instruments Index Contents: Page Measuring Centres MC 320 Energy meter, MC 330 Multimeter 3 MC 760/UMC 760 Network Analyzer, MC 750/UMC 750 - Network Recorder 5 MC 740 Multifunction

More information

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances

More information

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS Capacity Technology Inverter Technology Noise Level Operating Temperature Humidity Harmonic Distortion Total DC bus voltage Battery recharge time (After Complete discharge) to 100% charge Crest Factor

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master

More information

San Diego Community College District

San Diego Community College District San Diego Community College District District-Wide Smart Metering Guidelines for NEW & RENOVATED BUILDINGS City College, Mesa College, and Miramar College Prepared by: Randall Lamb September 20, 2011 Revised:

More information

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet PowerLogic power-monitoring units PM5350 power meter Technical data sheet Mid-range metering PM5350 Functions and characteristics PE86278 The PowerLogic PM5350 power meter offers all the measurement capailities

More information

Main catalog. Electricity meters For modular enclosures and DIN rail

Main catalog. Electricity meters For modular enclosures and DIN rail Main catalog Electricity meters For modular enclosures and DIN rail Introduction DIN rail mounted electricity meters Modular DIN rail products offer a wide range of functions to be integrated in electrical

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Polyphase kwh Electricity Meter

Polyphase kwh Electricity Meter Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2

More information

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? PowerLogic PM800 series power meters Buildings Industry Data Center Compact power, energy and power quality meters The Square D PowerLogic

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs EPOS (Electronic Point of Sale) Systems Emergency devices (lights/alarms) Electro-medical devices Telecommunication

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World Catalogue 2002 Automatic capacitor banks Building a New Electric World 0Contents Power factor correction 2 Power factor equipment selection guide 3 General technical data 4 Capacitors and banks 50 z 6

More information

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that

More information

Power Meter Series 800

Power Meter Series 800 PowerLogic power-monitoring units Power Meter Series 800 Technical data sheet 2007 Functions and characteristics E90463 PB101813-51 PB101823-50 DB111799 Front view of Power Meter Series 800 meter with

More information

1. INTRODUCTION FEATURES 2. PROGRAMMING

1. INTRODUCTION FEATURES 2. PROGRAMMING 1. INTRODUCTION Mono phase compensation systems are not useful in plants where unbalanced loads exist. In such plants compensation has to be done by measuring all 3 phase parameters individually. Devices,

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

UMG 96L. Universal Measuring Device. Operating Instructions. Brief instructions see last page

UMG 96L. Universal Measuring Device. Operating Instructions. Brief instructions see last page Art. Nr. 33.03.053 Universal Measuring Device UMG 96L Operating Instructions Brief instructions see last page Supply Mean value www.janitza.de w Peak value Minimum value Key 1 Key 2 Programming mode Sum

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Panorama Electricity meters For reliable values of energy consumption

Panorama Electricity meters For reliable values of energy consumption Panorama Electricity meters For reliable values of energy consumption Why measure Electrical Energy Energy cost is on the rise. It is therefore in the interest of both private and commercial customers

More information

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB. Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Managing. Energy management and power analysis

Managing. Energy management and power analysis management and power analysis Power monitors IN 96 and 144 - Selection table... 68 - IN 96, recdigit NOUS... 70 - IN 144, recdigit POWER... 72 - Multi-display recisplay... 73 Winthor software... 74 Managing

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Measuring transducers for all electrical AC-variables

Measuring transducers for all electrical AC-variables Measuring transducers for all electrical AC-variables SWMU Measuring transducer for AC with integrated current transformer...................236 page Order List page NMC Clip-on measuring transducers for

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES CONTENTS / EN CONTENTS Title Page I. SAFETY INFORMATION...1 II. INTRODUCTION...3 III. SPECIFICATIONS...4 3-1 Environmental Conditions...4

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current

Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current CVM system analyzers M5 M.5.01 GB Contents Page Introduction 3 Three-phase system analyzers 4 Applications 5 Three-phase system analyzers CVM-NRG 96 6 CVM-96 7 CVM-144 8-9 CVMk 10-11 Analogue I/O equipment;

More information

E-Series protective relay family

E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays E-Series protective relay family Reliable protection for every application Eaton s E-Series relay

More information