UMG 96L. Universal Measuring Device. Operating Instructions. Brief instructions see last page
|
|
|
- Sheila Peters
- 9 years ago
- Views:
Transcription
1 Art. Nr Universal Measuring Device UMG 96L Operating Instructions Brief instructions see last page Supply Mean value w Peak value Minimum value Key 1 Key 2 Programming mode Sum measurement Phase to phase Password Voltage transformer Current transformer Dok Nr D Janitza electronics GmbH Vor dem Polstück 1 D Lahnau Support Tel. ( ) Fax ( ) [email protected] Internet:
2 Table of contents The meaning of symbols 3 Hints for the user 3 Receipt control 3 Contents of delivery 3 Hints for maintenance 4 Service 4 Product description 5 Intended use 5 Functional description 5 Installation 6 Mounting place 6 Measuring and operating voltage 6 Current measurement 7 Sum current measurement 7 Connecting options 8 Putting into service 10 Installation 10 Attach measuring and operating voltage 10 Connect measuring current 11 Check phase assignment 11 Check current direction 11 Check measurement 11 Check phase power 11 Check sum power 11 Elimination of errors 12 Error messages 13 Usage and indication 14 Indication mode 14 Programming mode 14 Key functions 15 Table, measured value indication 16 Current transformer 18 Voltage transformer 19 Averaging times 20 Measured value indication 21 Measured value rotation time 21 Measured value selection 22 Delete minimum and maximum values 23 Delete energy 23 Working hours counter 24 LCD contrast 24 Software Release 25 User password 25 Uncertainty of measurement 26 Configuration data 28 Declaration of conformity 29 Safety guidelines 29 Test voltage 29 EMC requirements 29 Technical data 30 Ambient conditions 30 Measurement 30 Connectable cables 30 Dimensions 31 Connection example 31 Brief instructions 32 Change current transformer ratio 32 Call up measured values 32 All rights reserved. No part of this manual may be reproduced or duplicated without the written permission of the author. Any contraventions are punishable and will be prosecuted with all legal means. No liability can be taken for the faultless condition of the manual or damage caused by the use of it. As failures cannot be avoided completely, we shall be very grateful for any advice. We are anxious to remove all failures as soon as possible. The mentioned software and hardware descriptions are registered trademarks in the most cases and are subject to the regulations by law. All registered trademarks are property of the corresponding companies and are fully recognized by us. Issue Note First Edition Measurement uncertainly Page 10/12 marking voltage measurement Page 9, Abb.5, 6 and 8 been cancelled Storage temperature -25 C. Page 2
3 The meaning of symbols The symbols, which are used in this manual, have the following meaning: c m Beware of dangerous electrical voltage. This symbol shall warn you about possible danger, which can occur during installation, putting into service and usage. Hints for the user This device may be inserted and used by qualified personnel only according to the safety regulations. Please follow the legal and safety regulations for the corresponding application while using the device. Qualified personnel are persons, who are familiar with installation, mounting, putting into service and operation of the product and have qualifications according to their occupation, for example: - Education or instruction resp. the right to switch on or off, ground or characterize current circuits or devices according to the standards of safety techniques. - Education or instruction in care and use of safety equipment according to the standard safety techniques. Receipt control In order to ensure a perfect and safe use of the device, a proper transport, expert storage, erection and mounting and careful usage and maintenance is required. In case that a safe operation can no longer be granted, the device has to be put out of service and has to be protected against unintentional putting into service. A safe operation can no longer be assumed, if the device shows visible damage, does not work in spite of intact net supply, has been exposed to disadvantageous conditions for a longer time (e.g. storage beyond allowed climate without adaption to the room climate, dew etc.) or transport use (e.g. falling from great height, even without visible damage). Please test the contents of delivery for completion, before starting the installation of the device. Contents of delivery 1 pc. UMG96L, 2 pcs. fixing brackets, 1 pc. manual. As an option, a seal with part no can be delivered. All delivered options and versions are listed on the delivery papers. m Attention! If the device is not used according to this manual, a safe use cannot be granted, and the instrument might cause danger. c Attention! If a UMG 96L is installed in panels of metal, the panel must be earthed. This manual also describes options, m which have not been delivered and do not belong to the contents of delivery. Page 3
4 Hints for maintenance Before delivery the device is tested in various safety checks and marked with a seal. If the device is opened, these checks must be repeated. For instruments, which are opened outside the manufacturing works, no warranty is granted whatsoever. Repairing and calibration Repairing and calibration work can be carried out in the manufacturing works only. Front foil The cleaning of the front foil has to be effected with a soft cloth using a common cleansing agent. Acid or acidic agents are not allowed for cleaning. Waste management The UMG96L can be disposed and recycled as electronical waste according to the legal regulations. Service If there are questions, which are not described in this manual, please contact us directly. For an efficient handling we need the following information: - Description of device (see type plate), - Serial digit (see type plate), - Software Release, - Measuring and operating voltage and - detailed description of error. You can reach us: Monday until Thursday between 07:00 and 15:00 and Friday between 07:00 and 12:00 Janitza electronics GmbH Vor dem Polstück 1 D Lahnau Support: Tel. ( ) Fax ( ) [email protected] Internet: Page 4
5 Product description Intended use The UMG96L is suitable for fix mounting and the measurement of voltage, current, power etc. in low voltage switchgear. The measurement is designed for 3 phase systems with neutral conductor (TN and TT-mains). The UMG96L is suitable for mounting in fix and weather protected panels. Conducting panels must be earthed. Due to the high resistance against interference, the UMG 96L is suitable for continous and unsupervised operation. As the UMG96L receives its power from phase of the measuring voltage, at least phase and the neutral conductor N must be connected. The attached voltage must be within the range of the measuring and operation voltage shown on type plate. Either../5A or../1a current transformers can be connected to the current measuring inputs. The connection of the measuring and operating voltage is carried out on the back side of the UMG96L via all-insulated spring power clamps. The measuring and operating voltages must be connected to the UMG 96L via a separation (switch or power switch) and an overcurrent protection fuse (2-10A) in the building installation. The separation (switch or power switch) must be near the UMG 96L and easily accessible. Functional description The electronical three phase measurement system determines and digitalizes the effective values of voltages and currents in 50/60 Hz networks. The operating voltage for operation of UMG96L is generated by the measuring voltage -N. A random test measurement is carried out each second at all current and voltage inputs. Measuring signal interruptions, which last longer than one second are safely recognized. For each random test one period is scanned. From those sampled values the microprocessor calculates the electric quantities. These measured values are indicated within the programmable display. The energy as well as the minimum and maximum values are stored every 15 minutes whereas the programmed data are stored immedately is a none volatile memory (EEPROM). The scanning frequency for all measuring inputs is calculated from the net frequency of phase 1. At a net frequency of 50Hz the scanning frequency is 2,5kHz and for 60Hz it is 3,0kHz. N PE 3M 3M 3M Generation of operating voltage Voltage measurement UMG96L Diagr. Generation of the operating voltage from measurement voltage. Page 5
6 Installation Mounting place The UMG96L is suitable for a fix insertion into low and medium voltage switchgear. Any mounting position is possible. Measuring and operating voltage The operating voltage of the UMG96L is generated by the measuring voltage. The measurement is designed for three phase systems with neutral conductor (TN and TT mains). The measuring and operating voltages must be connected to the UMG 96L via a separation (switch or power switch) and an overcurrent protection (2-10A) within the building installation.the connection of the measuring and operating voltages is carried out at the back side of the UMG 96L via shock protected spring clamps. 230V/400V Standard version Phase and the neutral conductor N must be connected, and the attached voltage must be within the range of the measuring and operating voltage. - The connection wires for the operating voltage leading to the UMG96L must be suitable for voltages up to 300V against ground. - The measuring and operating voltage has to be protected by a fuse, which must be in the range of 2A to 10A. - A switch or power switch for the operating voltage must be provided within the building installation. - The switch has to be near the instrument and easily accessible. - The switch must be marked as separation for this instrument. 120V/220V Special version Phase and the neutral conductor N must be connected, and the attached voltage must be within the range of the measuring and operating voltage. 60V/110V Special version Phase and the neutral conductor N must be connected, and the attached voltage must be within the range of the measuring and operating voltage. c Attention! The limits indicated in the technical data may not be exceeded, not even while checking and putting into service of the UMG 96L. c Attention! Before the device is connected to voltage for the first time, it should be deposited the installation room for at least 2 hours, to create a temperature assimilation and avoid condensation and dew. Page 6
7 Current measurement The current measurement is carried out via../ 5A or../1a current transformers. In case that the current has to be measured by an Amperemeter in addition to the UMG96L, the Amperemeter has to be connected in series to the UMG96L. In mains with voltage up to 300VAC against ground, currents up to 5A can be connected and measured directly to the UMG 96L. Verbraucher Consumer l L l UMG96L K k k A Einspeisung Supply Diagr. Connection example: UMG96L with Amperemeter in series. Inaccuracy The inaccuracy of the current measuring input is +- 1% of the measuring range (5A). Therefore, the inaccuracy of the current measurement is +-50mA. Example: Inaccuracy With a current transformer 200/5A, the measuring range is 200A. The inaccuracy is +-1% of 200A = +-2A. Resolution The maximum resolution of the current measuring inputs is 10mA. The indication changes in 0.01A steps. Example: Resolution current transformer 200/ 5A With a current transformer ratio of 200/5A, a resolution of 10mA*40 = 400mA is effected. The display changes in 0.4A steps. Small currents The minimum working current is 20mA. At short circuited or open current measurement input, the UMG 96L can indicate a small current. This current is within the range of the allowed measurement inaccuracy. Sum current measurement If the current measurement is carried out via two current transformers, the total transformer ratio must be set to the UMG96L. Example: Sum current transformer A current measurement is carried out via one current transformer with a ratio of 1000/5A and another one with a ratio of 200/5A. The sum measurement is carried out with a sum transformer 5+5/5A. The UMG96L has to be programmed as follows: Primary current: 1000A + 200A = 1200A Secondary current: 5A c c m Verbraucher 1 Consumer 1 L l K k Einspeisung 1 Supply 1 AK AL BK Bl K l k l UMG96L Verbraucher 1 Consumer 1 L K l k Einspeisung 1 Supply 1 Attention! Current transformers may not be handled in open condition of the secondary, as the secondary clamps can lead live voltage. Attention! Prior to connecting or exchanging the UMG 96L, the secondary clamps of the external current transformers have to be short circuited. Attention! The program allows current and voltage transformer ratio setting only, if the maximum phase power can reach up to 50.0MW and the sum power can reach a maximum value of 150.0MW. Page 7
8 Connecting options UMG96L Voltage Measurement see type plate Current measurement 0,02.. 5A UMG96L Voltage Measurement see type plate Current measurement 0,02.. 5A N 1k 1l 2k 2l 3k 3l N 1k 1l 2k 2l 3k 3l PEN k l k../5(1)a../5(1)a l k l../5(1)a Verbraucher Consumer PEN k../5(1)a l k l../5(1)a Verbraucher Consumer Diagr.: Connection example 1 Four wire measurement with three current transformers UMG96L Voltage Measurement see type plate Current measurement 0,02.. 5A Diagr: Connection example 2. Four wire measurement with two current transformers. UMG96L Voltage Measurement see type plate Current measurement 0,02.. 5A N 1k 1l 2k 2l 3k 3l N 1k 1l 2k 2l 3k 3l u u u u u u x x x X X X x x x X X X PEN U U U k l k../5(1)a../5(1)a l k l../5(1)a Verbraucher Consumer PEN U U U k../5(1)a l k l../5(1)a Verbraucher Consumer Diagr.: Connection example 3 Measurement with three voltage transformers and three current transformers. Diagr.: Connection example 4 Measurement with three voltage transformers and two current transformers. Page 8
9 UMG96L Voltage Measurement see type plate Current measurement 0,02.. 5A N 1k 1l 2k 2l 3k 3l N k l k../5(1)a../5(1)a l k l../5(1)a Verbraucher Consumer PE Diagr.: Connection example 7 Measurement in IT networks via three current transformers. Page 9
10 Putting into service The putting into service of the UMG 96L should be carried out as follows: Installation The UMG96L is designed for mounting in low voltage distributions, which contain overvoltage in measurement category III. The UMG96L is suitable for installation in fixed and weather proof panels. Conducting panels must be earthed. Any mounting position is possible. For mounting on front panels or doors, the delivered fixing brackets have to be used. Fixing brackets 90 Diagr. Side view Panel max Attach measuring and operating voltage The allowed measuring and operating voltage of UMG 96L is indicated on the type plate. c Attention! Mesuring and operating voltage, which do not correspond to the indication on the type plate, can lead to malfunction and damage of the instrument. The connection wires for measuring voltage leading to the UMG96L must be suitable for voltages up to 300V against ground and 520V phase to phase. After connecting the stated measuring and operating voltage to the UMG 96L, all segments of the display appear. After approx. two seconds, the UMG 96L switches to the first measured value indication. In case that no indication appears, please check, if the attached operating voltage is within the rated voltage range. S V J M A D E P UMG96L 45-65Hz IP20 2,5VA Made in Germany 4 N A Spannungsmessung Voltage Measurement Strommessung/Current Measurement k l k l k l m Program current and voltage transformers When the device leaves the manufacturer, a current transformer of 5/5A is set. The set voltage transformer ratio has to be changed only, if a voltage transformer is connected. When connecting voltage transformers, please observe the allowed measuring and operating voltage stated on type plate! Page 10
11 Connect measuring current The UMG96L is designed for the connection of../1a and../5a current transformers. With the current inputs, only alternating current but no direct current can be measured. c Attention! Current transformers may not be handled in open condition, as there might be live voltage at the secondaries. Please connect the current inputs one after the other, and compare the indicated current of the display with the actual current. Please note, that the current transformer ratio is set to 5/5A and has to be adapted to the existing current transformers. In case that the current transformer is short circuited on the secondary, the indicated current at the corresponding conductor at UMG 96L has to decrease to a value, that corresponds to the secondary current plus tolerance. The current indicated by UMG 96L, has to conform to the input current, under consideration of the current transformer and tolerance. S V J M A D E P UMG96L 45-65Hz IP20 2,5VA Made in Germany A Spannungsmessung Voltage Measurement Strommessung/Current Measurement k l k l k l Check phase assignment The assignment of the outer conductors to the current transformer is correct, if a current transformer is short circuited on the secondary, and the indicated current in the corresponding phase decreases to a value at the UMG96L, which corresponds to the secondary current plus tolerance. 4 N 3 m Check current direction Short circuit two current transformers on the secondary. The real power in the connected phase has to be: Positive (+) for consumption of real power and negative (-) for supply of real power (power station service). In case that no real power is indicated, the assignment of voltages and currents may be wrong. Check measurement Provided that all voltage and current inputs are connected correctly, the phase and sum power is calculated and displayed correctly. Check phase power In case that a current transformer is assigned to the wrong outer conductor, the corresponding power is measured and indicated incorrectly. The assignment of the outer conductor and current transformer is correct, if no voltage is measured between the outer conductor and the primary of the corresponding current transformer. To ensure that the outer conductor at the voltage input is assigned to the right current transformer, please short circuit the secondary of the corresponding current transformer. The apparent power of this phase at UMG 96L must be indicated by zero. If the apparent power is indicated correctly, but the real power has a - sign, the current transformer clamps are interchanged, or power is supplied to the energy supplier. Check sum power Provided that all voltage, current and power in the corresponding phase is indicated correctly, the sum power must be displayed correctly by UMG 96L either. For verification, the sum power measured by UMG96L should be compared to the energy stated by the real and reactive energy counters of the supplier. Page 11
12 Elimination of errors Error Display dark. Reason Prefuse released. Device defective. Elimination Insert fuse. Send the device to the producer for repair. Measured value cannot be called up. The indication has been deleted from measured value selection. Add the required measured value indication to the measured value selection. No current indication. Corresponding voltage is not connected. Connect corresponding voltage. Current too small. Current measurement in wrong phase Check and correct connection. Current incorrect. Current measurement in wrong phase Current transformer programmed incorrectly. Measuring range exceeded. Check and correct connection. Read ratio of current transformer and program accordingly. Insert a current transformer with a higher ratio. The current peak at measuring input was exceeded caused by harmonic waves. The current at measuring input was below measuring range. Insert a current transformer with a higher ratio. Attention! Please ensure, that the measuring inputs are not overloaded. Insert a current transformer with a smaller ratio. Check and correct connection. Voltage L-N incorrect. Voltage L-L too small / too high. Measurement in wrong phase. Voltage transformer ratio programmed incorrectly. Phase conductors interchanged. N not connected. Voltage transformer ratio programmed incorrectly. Check and correct connection. Read the voltage transformer ratio at the voltage transformer and program accordingly. Check and correct connection. Check and correct connection. Read voltage transformer ratio at the voltage transformer and program accordingly. Page 12
13 Error Phase shift ind/cap. Reason Current path is assigned to the wrong voltage path. Elimination Check and correct connection. Programmed get lost. data The device was exposed to electro magnetical disturbance, which was higher than those mentioned in the technical data. Improve external protection measures such as protection, filtering, earthing and local separation. Real power too small / too high. Current transformer ratio is programmed incorrectly. Current path is assigned to the wrong voltage path. Read current transformer ratio and program accordingly. Check and correct connection. Real power supply / consumption interchanged. At least one current transformer connection is interchanged. Current path is assigned to the wrong voltage path. Check and correct connection. Check and correct connection. Err in display. See error messages The device does not operate in spite of the above. Device defective. Please send the device back to the producer with a detailed description of the error. Error messages While exceeding an allowed measured value range, the UMG 96L indicates the error message Err. An exceeding of a measured value range arises, if at least one of the three existing current or voltage inputs or the frequency is out of the specified measuring range. The symbols "V", "A" and Hz indicate, which measured value is out of range. The phase is marked by the arrows upwards in which the exceeding occured. A = Current path V = Voltage path Hz = Frequency Hz VA m Attention! Voltage and current beyond the specifications may destroy the device. Exceeding of measuring range in phase // Page 13
14 Usage and indication The usage of the UMG96L is carried out via the keys one and two. Measured values and programming data are indicated on the liquid crystal display. You must distinguish between Indication mode and Programming mode. By entering a password, you can avoid unintentional change of programming data. Indication mode In indication mode please scroll through the programmed measured value indications by using the keys 1 and 2. When the device is delivered, you can call up all measured values shown in table 1. For each measured value indication, up to three measured values are indicated. The measured value rotation allows to indicate all selected measured values on an alternate basis with a selectable changing time. cap cosϕ ind cap cosϕ ind cap cosϕ ind Programming mode Key1 MkWh MkVArh Hz S L-L CT VT K1 K2 1 2 Key 2 Programming mode In programming mode the settings, which are necessary for the operation of the UMG96L, can be indicated and changed. Pressing the keys 1 and 2 simultaneously for about 1 second, you reach programming mode via the password indication. If no user password is programmed, you reach the first programming menu directly. The programming mode is marked with the text in the display. With key 2 you can shift between the programming menues. If you are in the programming mode and no keys are pressed for 60 seconds, or you press the keys 1 or 2 simultaneously for approx. 1 second, you return to the indication mode. Programming menus: - Current transformer, - Voltage transformer, - Averaging times, Measured value indications - Changing time, - Measured value selection, - Measured value rotation, - Delete minimum and peak values, - Delete energy, - LCD contrast, - Software Release, - User pasword. Page 14
15 Key functions Indication mode Password Programming mode simultaneous 1 2 Programming Scroll Change mode long short 2 Measured values Measured values Measured values long 1 Measured values short simultaneous 1 2 Programming menu Programming menu Programming menu Programming menu long short 2 1 Confirm selection 2 short digit +1 long digit -1 2 short value *10 (decimal point to the right) flashing 2 long value /10 (decimal point to the left) Page 15
16 Table, measured value indication Measured values -N Voltage -N Voltage -N Voltage Maximum values -N Voltage -N Voltage -N Voltage Minimum values -N Voltage -N Voltage -N Voltage Measured values - Voltage - Voltage - Voltage Maximum values Real power Real power Real power Minimum values Real power Real power Real power Measured values Current Current Current Mean values Current Current Current Maximum values Current Current Current Max. values Curr. mean val. Curr. mean val. Curr. mean val. Measured value Σ Current in N Mean value Σ Current in N Maximum value Σ Measured value current in N Maximum values Σ Mean value current in N Measured values Real power Real power Real power Mean values Real power Real power Real power Maximum values Real power Real power Real power Measured value sum real power Mean value sum real power Maximum value (Consumption) sum real power meas. Maximum value (Consumption) sum real power, mean Measured values Apparent power Apparent power Apparent power Mean values Apparent power Apparent power Apparent power Maximum values Apparent power Apparent power Apparent power Measured value sum apparent power Mean value sum apparent power Maximum value sum meas. value apparent power Page 16
17 Measured values Reactive power Reactive power Reactive power Mean values Reactive power Reactive power Reactive power Max. values (ind) Reac. power Reac. power Reac. power Measured value Sum reactive power Mean value Sum reactive power Max. value (ind) Sum reactive power Measured value cos(phi) cos(phi) cos(phi) Measured value Sum cos(phi) Measured value Frequency Measured value (Consumption) Sum real energy Measured value Sum reactive energy(ind) Working hours counter Page 17
18 Current transformer Current transformers with either 1A or 5A secondary can be connected to the UMG96L. A transformer ratio of 5A/5A is preset by the manufacturer. In programming mode the current transformer setting is marked by the symbol CT. Primary (5.00kA = 5000A) k A Programming In programming mode please scroll to the current transformer ratio by pressing key 2. Confirm the selection by pressing key 1. The first digit of the primary current flashes and can be changed by pressing key 2. If key 1 pressed again the next digit will be selected and flashes now. If the entire digit flashes, the decimal point can be moved. Press key 2 shortly - The decimal point moves to the right. Press key 2 longer - The decimal point moves to the left. If no digit flashes anymore, you can shift to the indication of the voltage transformer. Secondary Current transformer symbol Example: Sum current transformer A current measurement is carried out via two current transformers, one with a ratio of 1000/ 5A and another transformer with a ratio of 200/ 5A. The sum measurement is carried out with a sum current transformer 5+5/5A. The UMG96L has to be programmed with the following values: CT Primary current: 1000A + 200A = 1200A Secondary current: 5A m Attention! The program allows current and voltage transformer ratio setting only, if the maximum phase power can reach up to 50.0MW and the sum power can reach a maximum value of 150.0MW. Page 18
19 Voltage transformer The phase to phase voltage (L-L) is indicated on display of the UMG 96L as secondary and primary voltage. The transformer ratio is calculated from the programmed primary and secondary voltage. In programming mode, the voltage transformer settings are marked by the symbol VT. The standard version is preset by the manufacturer with a ratio of 400V/400V. The secondary voltage is always indicated in V. The corresponding symbol V is not displayed. The primary voltage is indicated in V or kv. The corresponding symbol is displayed in V or kv. Primary voltage Secondary voltage Phase to phase Voltage transformer ratio V L-L VT UMG96L Setting range voltage transformer Version Type plate L-L secondary L-L primary Standard version V 400V 100V.. 60kV (400V) Special version V 200V, 220V 100V.. 60kV (200V) Special version V 100V, 110V 100V.. 60kV (100V) Programming In programming mode, please scroll to the voltage transformer setting by pressing key 2. Confirm selection with key 1. The first digit of the primary voltage flashes and can be changed by pressing key 2. If key 1 is pressed again the next digit will be selected and flashes. If the entire digit flashes, you can move the decimal point. If no digit flashes anymore, you may shift to indication and programming of the outputs by pressing key 2. Primary voltage is 10,0kV kv L-L VT Secondary voltage is 100V Example: Voltage transformer ratio 100V/10kV m Attention! The program allows current and voltage transformer ratio setting only, if the maximum phase power can reach up to 50.0MW and the sum power can reach a maximum value of 150.0MW. Page 19
20 Averaging times A mean value is calculated for the most at the current and power values. A common averaging time for the current measured values,, and N, as well as one for power measured values, real power, apparent power and reactive power is programmable. Method of taking the mean The used exponential method reaches at least 95% of the measured value after the set averaging time. ME n = ME n-1 + (MA-ME n-1 ) / N Presettings: Averaging time of currents = 900 seconds Averaging time of power = 900 seconds The following averaging times are selectable: 5, 10, 30, 60, 300, 480, 900 seconds ME n MA n N = indicated mean value = measured value = consecutive digit = digit of measured values, of witch mean values shall be built. Programming of averaging time Averaging time for real power In programming mode please scroll to the averaging time for power with key 2. Confirm selection by pressing key 1. W The averaging time flashes and can be changed by pressing key 2. Confirm changed averaging time with key 1. The averaging time stops flashing. The averaging time for power has been programmed. By using key 2 you can now shift to programming menu Averaging time for current. Example for the averaging time of real power mean value, here 900 seconds. S Averaging time for Currents In programming menu please scroll to the averaging time for currents. Confirm selection by pressing key 1. MkWh A MkVArh S The averaging time flashes and can be changed by pressing key 2. Confirm changed averaging time with key 1. The averaging time stops flashing. The averaging time for currents has been programmed. By using key 2 you can now shift to programming menu Rotation time. Example for the averaging time of current mean value, here 30 seconds. Page 20
21 Measured value indication Once in a second all measured values are calculated and can be indicated on the display. Two methods are available for calling up the measured value indications (see table 1). - The selection of measured value indications via the keys 1 and 2, herein called measured value selection. - The automatically rotating indications of selected measured value indications, herein called measured value rotation. A measured value rotation time has be programmed additionally for the measured value rotation. All mesured values for the measured value selection are preset by the manufactures. For the automatic rotation nothing is preset by the manufacturer. The rotation time is preset with 0 seconds. Measured value rotation time Both methods are available simultaneously. The measured value rotation is programmed, if at least one measured value indication and one measured value rotation time bigger than 0 seconds is programmed. If no key is pressed for about 60 seconds, an automatical change to rotation mode will be carried out, and all programmed measured values will be indicated one after the other. Setting range of measured value rotation time: seconds If 0 seconds are programmed, no rotation will be carried out. Nevertheless, measured value indications which are not programmed in the measured value selection, can be used for measured value rotation. Rotation time in seconds indicated S Abb. Programming In programming mode please scroll to the menu measured value rotation, by using key 2. Confirm selection with key 1. The first digit of the rotation time flashes and can be changed by pressing key 2. By pressing key 1 again the next digit will be selected and flashes. If no digit flashes anymore, you can shift to programming menu Measured value selection by pressing key 2. Page 21
22 Measured value selection All measured values stated in table 1 (see page 16 and 17) can either be displayed via keep 1 and 2 measured value selection or automatically measured value rotation. All measured values for the measured value selection are preset by the manufakturer. For the automatical measured value rotation nothing is preset by the manufakturer. The condition of the selection is indicated by the output symbols. These symbols have the following meaning: Measured value selection K1 The indication can be reached via the keys. K1 The indication cannot be reached via keys. Measured value rotation K2 The indication changes automatically. K2 The indication does not change automatically. Programming In programming mode please scroll to programming menu mesured value indication by pressing key 2. Confirm selection by pressing key 1. The first measured value indicated stated in table 1 (see page 16 and 17) occurs. A selection of the measured value indication is carried out by pressing the keys quickly. Key 1 - Scroll to the right within the measured value indications. Key 2 - Scroll downwards within the measured value indications. For the selected measured value indication, it can now be determined whether it will be available for measured value selection and for automatic rotation. The selection is carried out by an extended push on keys 1 or 2. Key 1 - Measured value selection. Key 2 - Automatic rotation. Measured value indication of the current values A K1 K2 Measured value selection Measured value rotation Once the programming is finished, you return to indication mode by pressing keys 1 and 2 simultaneously. Page 22
23 Delete minimum and maximum values In programming mode, Deletion of minimum and maximum values is marked by arrows upwards and downwards. All minimum and maximum values will be deleted simultaneously in menu Deletion of minimum and maximum values. An exception is the maximum value of the current mean value. The maximum value of the current mean value can also be deleted directly in indication menu by an extended pressing of key 2. Delete In programming mode please scroll to Deletion of minimum and maximum values by pressing key 2. With key 1 you can shift between the indicated digits 0 and 1. These digits have the following meaning: 0 = Minimum and maximum values not to be deleted. 1 = Minimum and maximum values to be deleted. Leave menu Deletion of minimum and maximum values by pressing key 2. In case that digit 1 was displayed, all minimum and maximum values were deleted. Delete energy The real and reactive energy can only be deleted together via the keys. Wh Delete In programming mode please scroll to the menu delete energy by using key 2. By pressing key 1 you can shift between digits 0 and 1. These digits have the following meaning: 0 = Real and reactive energy not to be deleted. 1 = Real and reactive energy to be deleted. Leave menu Delete energy by pressing key 2. In case that digit 1 was displayed real and reaktive energy were deleted. Wh Page 23
24 Working hours counter The working hours counter detects the time, in which the UMG96L measures and indicates data. The time is measured with a resolution of 15 minutes and is indicated in hours. The working hours counter cannot be deleted. h Display example: The UMG96L indicates working hours. LCD contrast The favoured view for the LCD display is from below. The LCD contrast of the LCD display can be adapted by the user. The contrast setting is possible in the range from 0 to 7. 0 = very light 7 = very dark Programming In programming mode please scroll to LCD contrast by pressing key 2. Confirm selection with key 1. The first digit of the contrast setting is flashing. Move to the right digit with key 1. Now you can change the digit with key 2. Afterwards you can shift to programming menu user password by pressing key 2. Page 24
25 Software Release The internal software of the UMG96L will be improved and extended continuously. The software update is registered in the device by a specific number the so called software release. The software release cannot be changed by the user. Example: In UMG96L, the software release 1.23 is installed. User password A user password can be programmed in order to avoid an unintentional change of programming data. Only after entering the correct password, a shifting into the following programming menues possible. No user password by the manufacturer is preset (000). In this case, the password menu will be skipped and you reach the current transformer menu directly. In case that a user password was programmed, a 000 appears in the display of the password menu. The first digit of the password menu flashes and can be changed with key 2. By pressing key 1, the next digit will be selected and flashes. Only after the correct password was entered, you reach the programming menu for the current transformer. In case that a changed password is not known anymore, the device must be sent back to the manufacturer. User password Page 25
26 Uncertainty of measurement Quantity Indicating range Measuring range 1) Measurement uncertainly 2) Auxiliary voltage 5) V Voltage L-N kV V +-1,5% rng Voltage L-L kV V +-2,0% rng Current 0,00.. 9,99kA 0,02.. 6,00A +-1,0% rng Current in N 0,00.. 9,99kA 0, ,00A +-3,0% rng Real power, consumption, sum 0,00W.. 150MW 3,9W.. 3,825kW +-1,5% rng Real power, supply, sum -0,00W MW -3,9W.. -3,825kW +-1,5% rng Apparent power, sum 0,00VA.. 150MVA 3,9VA.. 3,825kVA +-1,5% rng Reactive power (Q0), sum 0,00var.. 150Mvar 3,9var.. 3,825kvar +-1,5% rng Auxiliary voltage 5) V Voltage L-N kV V +-1,5% rng Voltage L-L kV V +-2,0% rng Current 0,00.. 9,99kA 0,02.. 6,00A +-1,0% rng Current in N 0,00.. 9,99kA 0, ,00A +-3,0% rng Real power, consumption, sum 0,00W.. 150MW 1,8W.. 2,4kW +-1,5% rng Real power, supply, sum -0,00W MW -1,8W.. -2,4kW +-1,5% rng Apparent power, sum 0,00VA.. 150MVA 1,8VA.. 2,4kVA +-1,5% rng Reactive power (Q0), sum 0,00var.. 150Mvar 1,8var.. 2,4kvar +-1,5% rng Auxiliary voltage 5) V Voltage L-N kV V +-1,5% rng Voltage L-L kV V +-2,0% rng Current 0,00.. 9,99kA 0,02.. 6,00A +-1,0% rng Current in N 0,00.. 9,99kA 0, ,00A +-3,0% rng Real power, consumption, sum 0,00W.. 150MW 0,9W.. 1,2kW +-1,5% rng Real power, supply, sum -0,00W MW -0,9W.. -1,2kW +-1,5% rng Apparent power, sum 0,00VA.. 150MVA 0,9VA.. 1,2kVA +-1,5% rng Reactive power (Q0), sum 0,00var.. 150Mvar 0,9var.. 1,2kvar +-1,5% rng cos(phi) 0,00i ,00c 3) Frequency (of voltage) 45,0.. 65,0Hz +-1,5% rdg Reactive energy, inductive v 6) < kvarh class 2 4) v 6) < kvarh class 2 4) v 6) >= kvarh class 2 4) Real energy, consumption v 6) < kWh class 2 4) v 6) < kWh class 2 4) v 6) >= kWh class 2 4) Working hours counter h +-2Min./Day m Page 26 Attention! The program allows current and voltage transformer ratio setting only, if the maximum phase power can reach up to 50.0MW and the sum power can reach a maximum value of 150.0MW.
27 These specifications presuppose a yearly calibration and a warm up time of 10 minutes. Used abbreviations: rng = of measuring range rdg = of measured value 1) Measuring range with scale factor = 1, (Current tranformer = 5/5A, 1/1A) 2 ) In the range of C and C, an additional error of +-0,5 of measured value has to be considered per K. 3 ) If the measured apparent power is in the range of 1%.. 100% of the measuring range, cos(phi) is indicated with an accuracy of +-3%. 4) Accuracy class according to DIN EN61036: , VDE0418part 7, IEC61036: A1:2000 5) The auxiliary voltage is taken from the measuring voltage. 6) The maximum indication range and the resolution of real and reactive energy depends on Transformer ratio v = vi * vu. vi = Transformer ratio of current transformer. vu = Transformer ratio of voltage transformer. Example: 200/5A -> vi = /100V -> vu = 10 v = vi * vu v = 40 *10 v = 400 Indication range and resolution for real and reactive energy Energy /kvarh /kwh , , v Transformer ratio v Page 27
28 Configuration data Description Display Setting range Presettings Current transf., primary CT 1A.. 10,0kA 5A Current transf., secondary CT 1A, 5A 5A Voltage transf., primary Type plate, V VT 100V kV 400V Type plate, V VT 100V kV 200V Type plate, V VT 100V kV 100V Voltage transformer, sec. Type plate, V VT 400V (not changeable) 400V Type plate, V VT 200V, 220V 200V Type plate, V VT 100V, 110V 100V Averaging time, current 5, 10,.. 900Sec. 900Sec. Averaging time, power 5, 10,.. 900Sec. 900Sec. Measured value rotation seconds 0 = no rotation Measured value selection All indications all indications LCD contrast Software Release not changeable x.xx User passwort = no password Working hours counter not changeable 0h Page 28
29 Declaration of conformity The UMG96L fulfills the protection guidelines of: Guideline 89/336/EWG in combination with DIN EN61326 ( ) as well as Guideline 73/23/EWG and 93/68/EWG in combination with EN ( ) Safety guidelines Safety requirements for electrical equipment for measurement, control, and laboratory use Part1: General requirements : EN :2001, IEC :2001 Test voltage Enclosure against measuring inputs : 2kV AC Between the inputs for measuring and auxiliary voltage and the current inputs exists a functional separation of 2000V AC. EMC requirements Electromagnetic emission : DIN EN61326: , table 4, class B Electromagnetic immunity : DIN EN61326: , table A.1 Enclosure : ESD test, IEC :2001 (4kV/8kV) : Electromagnetic RF-field, IEC :2002 (10V/m) : Netfrequent magnetic field, IEC :2000 (120A/m) AC-power line : AC-Power variation and dropout, IEC :2000 : Fast transients (Burst), IEC :2001 (2kV) : Powerful pulse (Surge), IEC :2000 (1kV L- N) : RF induced on lines, IEC :2000 (3V) Current transformer inputs : Fast transients (Burst), IEC :2001 (2kV) : Powerful pulse (Surge), IEC :2000 (1kV) : RF induced on lines, IEC :2000 (3V) Page 29
30 Technical data Weight : 250g Calorific value : 2,2MJ (610Wh) Ambient conditions Measurement category : III (Measurement within building installation) Pollution degree : 2 Protection class : II = with protective earth Ambient temperature : -10 C C Storage temperature : -25 C C Humidity : 15% up to 95% without dew Protection class Front : IP50 according to IEC60529 Front with seal (Option) : IP65 according to IEC60529 Back side : IP20 according to IEC60529 Mounting position : random Operating height : m over sea level Measurement Measuring inputs Measuring rate : 1 measurement per second Rated pulse voltage : 4kV Signal frequency : 45Hz Hz Scanning frequency : 2,5kHz/3,0kHz (Net frequency 50Hz/60Hz) Measuring and operating voltage : see type plate Fuse : 2A.. 10A (medium time lag type) Frequency of fundamental : 45Hz.. 65Hz Power consumption Phase (L-N) : ca. 0,1VA per phase. 230V/400V Standard version operating voltage : V AC Range : L-N 50V.. 255V, L-L 86V.. 442V 120V/220V Special version operating voltage : V AC Range : L-N 25V.. 160V, L-L 45V.. 277V 60V/120V Special version operating voltage : V AC Range : L-N 16V.. 80V, L-L 28V.. 139V Current measurement Power consumption : approx. 0,2VA Rated current at../5a (../1A) : 5A (1A) Minimum working current : 20mA Current limit at../1a : 1,2A (sinus shape) Current limit at../5a : 6A (sinus shape) Overload : 150A for 2 Sec. Accuracy class of energy measurement : class 2 Connectable cables One wire, multiple-wire, fine wire : 0,08-2,5mm 2 Pin contacts : 1,5mm 2, only one conductor may be connected per terminal! Page 30
31 Dimensions Cut out: 92 +0,8 x 92 +0,8 mm Panel max. 6 Fixing angles 42 6 Diagr. Side view S V J M A D E P UMG96L 45-65Hz IP20 2,5VA Made in Germany Type plate Diagr. Back view 4 N A Spannungsmessung Voltage Measurement Strommessung/Current Measurement k k k l l l m All dimensions in mm Connection example UMG96L Voltage Measurement see type plate Current measurement 0,02.. 5A N 1k 1l 2k 2l 3k 3l PEN k l k../5(1)a../5(1)a l k l../5(1)a Verbraucher Consumer Diagr.: Connection example 1 Four wire measurement with three current transformers. Page 31
32 Brief instructions Change current transformer ratio Shift to programming mode If you are in the indication mode please press the keys 1 and 2 simultaneously for approx. 1 second. Now you reach programming mode. The symbols for programming mode and for the current transformer CT appear. Confirm selection with key 1. The first digit of the primary flashes. Programming mode k A CT Change primary current: Change the flashing digit with key 2. Select the next digit to be changed by pressing key 1. The selected digit flashes. If the entire number flashes, the decimal point can be moved. Change secondary current: Only 1A or 5A can be set as secondary current. Select secondary current with key 1. Change flashing digit with key 2. Leave programming mode: Press both keys simultaneously for approx. 1 second. The current transformer setting will be stored and you return to indication mode. Current transformer symbol Primary current 1 2 k A CT Secondary current 1 2 Call up measured values Shift to indication mode If you are in programming mode please press the keys 1 and 2 simultaneously for approx. 1 second. Now you reach the indication mode. The symbol for programming mode does not appear in the display and the first measured value indication, e.g. for the voltage appears. Key 2 With key 2 you scroll between the different measured value indications for current, voltage, power etc. Key 1 With key 1 you scroll between the mean values, maximum values etc., related to the corresponding measured value. V 1 2 Page 32
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
1. INTRODUCTION FEATURES 2. PROGRAMMING
1. INTRODUCTION Mono phase compensation systems are not useful in plants where unbalanced loads exist. In such plants compensation has to be done by measuring all 3 phase parameters individually. Devices,
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
max 6f / computer max
POWER FACTOR REGULATORS computer max max 6f / computer max max 12f Instructions Manual ( M98234601-03-10A ) - 1 - Index 1 INTRODUCTION AND SAFETY RECOMMENDATIONS... 3 1.1 DELIVERY SPOT CHECK... 3 1.2 STARTING
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Energy Management Power Analyzer Type WM14-96 Basic Version
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Product Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03
PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
3-Phase Energy meter with serial S-Bus interface
Data sheet www.sbc-support.com 3-Phase Energy meter with serial S-Bus interface Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial),
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Safety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany
DIN EN ISO9001:2008 certified ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany Phone: +49 7229 1847 0 Fax: +49 7229 1847 222 E-mail: [email protected] Safety information
INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES
INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES CONTENTS / EN CONTENTS Title Page I. SAFETY INFORMATION...1 II. INTRODUCTION...3 III. SPECIFICATIONS...4 3-1 Environmental Conditions...4
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
EM-PQ 1500 Power Quality Monitor. Operating Manual
EM-PQ 1500 Power Quality Monitor Operating Manual 1 User notes: 2 Contents Page Page 1. Quick start... 5 2. Description... 6 2.1 Operating principle... 6 3. Installation... 8 3.1 Mounting... 8 3.2 Electrical
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7
Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual
Electricity Meters IEC/MID Residential ZxF100Ax/Cx E350 series 2 User Manual Date: 20.12.2011 File name: D000027979 E350 ZxF100Ax Cx series 2 User Manual EN.docx Landis+Gyr D000027979 EN n 2/54 Revision
FREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
Polyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
mecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
www.janitza.com UMG 96RM-P UMG 96RM-CBM Power Analyser Operating instructions and technical data
Item no. 33.03.160 MOD100 (20-250V) www.janitza.com Power Analyser UMG 96RM-P UMG 96RM-CBM Operating instructions and technical data Doc no. 1.040.083.0.k Janitza electronics GmbH Vor dem Polstück 1 D-35633
DC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
MasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
Operating Manual Remote Cost Control Monitor
Operating Manual Remote Cost Control Monitor INTRODUCTION: Congratulations on purchasing the Remote Cost Control. This is a state-of-the-art power monitoring socket that is highly accurate and easy to
Product Information Sheet UH28CS-12kV Hi Pot Tester
Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
5235 Single Phase Credit Meter
Electricity Meters Residential BS / IEC British Standard 5235 Single Phase Credit Meter User Manual & Technical Specification Date: 20/11/08 Filename: 5235 User Manual Q Pulse No:IB047 Landis+Gyr Page
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
Digital Clamp-on DMMs with uncompromising performance
Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy
60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration