Diaphragm Metering Pump MEMDOS E / DX
|
|
|
- Stuart Powers
- 9 years ago
- Views:
Transcription
1 MB / 1 General The MEMDOS E / DX combines the properties of the MEMDOS series working reliably for many years with the latest requirements in metering technology. Due to an improved flexibility and the further development of individual components, it can be integrated even more efficiently in metering processes. Heads and diaphragms are the same as for the existing pumps so that the continuity of spare parts keeping and service is ensured. Two models of the MEMDOS are available, each with or without microprocessor control. The smaller version can be used for capacities from to l/h and the larger version for capacities from to l/h. Pressures are admissible between 4 and 10 bar, depending on the size. If no control is required for constant metering, the motor is connected directly to the terminal box. In this case, MEMDOS E pumps are used. Three-phase and a.c. motors are available. To change the metering capacity, either the stroke length can be adjusted mechanically or the speed of the three-phase motor can be controlled by means of a separate frequency converter. The microprocessor-based MEMDOS DX is used if the pump is to be integrated in controls or automatic control systems. The intelligence of the MEMDOS DX is derived from the well-proved series of MAGDOS DE/DX solenoid metering pumps. It allows the adaption to a large number of different control signals and system monitoring equipment. It controls the chemical supply in two ways, for example: tank level control with alarm signal and low level indication. The signals required for external activation of the pump can be simple voltage-free closing contacts from water meters or controllers or analog 0(4)...20 ma signals. Depending on the version, the MEMDOS DX can be adjusted continuously between 0 and 142 strokes/min. for internal control. A single stroke follows each contact. In addition, the stroke frequency can be changed by pulse division or multiplication. Metering head MEMDOS pumps can be equipped with a PVC, PP or stainless steel head. Other materials are available upon request. The diaphragms are made of chemically and mechanically resistant materials. EPDM with a protective PTFE coat (Teflon) and a textile reinforcement are vulcanized onto a large-surface insertion part. Suction and discharge valve are fitted with two valve balls each for double sealing. For media with a viscosity of more than approx. 400 mpa*s spring-loaded single-ball valves should be used (opening pressure approx. 0.1 bar). Separating chamber The diaphragm flanges have been designed so that, in the case of a diaphragm rupture due to wear, no chemical enter the gear but is routed downwards through a drain pipe. A leakage probe according to data sheet MB can be fitted in order to detect the failure and cause the pump to stop. Drive To operate the pump three-phase or a.c. motors can be used for MEMDOS E pumps. The intelligent MEMDOS DX pumps with control unit are always equipped with a single-phase a.c. motor. The gearbox is made of light but inherently stable and high-alloyed cast aluminum. It contains a single-stage worm wheel set runing in an oil bath just as the roller bearings. Metering happens while the push rod is displaced by means of an eccentric. The suction stroke is caused by the resetting of the spring. To set the metering capacity by manual stroke adjustment, the spring-loaded diaphragm rod is locked at the corresponding position. Thus an adjustment range of 1:10 is possible.
2 MB / 2 Control unit In general the following functions are possible with the control unit: - Indication of operating states and menu guidance on 3-digit LC display. - Operating panel with four pressure-sensitive keys and three LEDs. - Internal control of stroke frequency, continuously adjustable between strokes/min., depending on the gear reduction. - External control by a) voltage-free contacts (mechanical or semiconductors). b) analog and ma signal. Technical data MEMDOS E / DX MEMDOS E / DX Types ) 26 1) ) 76 1) ) 156 1) ) ) Capacity at max. pressure 4) l/h Stroke volume ml/str Max. pressure bar Stroke freq. 4) 1/min Diaphragm-ø mm Stroke length mm Suction lift mbar Max. ambient temperature 3) C 40 Capacity E (3~) W Capacity DX (1~) W Weight plastic kg Memdos E Memdos DX Weight SS kg Memdos E Memdos DX ) Special sizes for 60 Hz operation. Flow rate and stroke frequency data refer to 60Hz operation. 2) Not suitable for 60Hz operation. 3) Ambient temperature for PVC metering head 40 C and for PP or stainless steel metering heads 60 C (for a short time 80 C). 4) At 60 Hz operation the values increase by factor 1.2. Additional fittings The precision and operational life of metering pumps can be increased considerably if the appropriate fittings are used. These are among others: - Double diaphragms which indicate a diaphragm failure and allow metering to be continued for a some time. - Pulsation dampeners for suction and discharge side. - ATE servomotors for automatic metering capacity adjustment. - External pump stop by voltage-free opening contact. - Warning alarm relay with voltage-free changeover contact (signaling of (almost) low level, life zero error with ma, remote switchoff). - Pulse multiplication for contact control with factor 2 / 4 / 8 / 16 / 32 / Pulse division for contact control with divisor 2 / 4 / 8 / 16 / 32 / Chemical tank level control with alarm signal and main alarm (pump stops). - Approximation initiators for indicating individual strokes. - Leakage probe for detecting leaking in the case of a diaphragm failure. - Application-oriented suction lines, also with level control for the medium to be metered. - Relief valves as safety valves to protect pump and system.
3 MB / 3 Technical data of the control unit Mains voltage V AC, Hz Electrical connection Safety plug with 2.5 m cable Power consumption (without motor) 10 W Insulation class F Protective class IP 65 * Pulse for contact activation min. 30 ms Voltage at pulse input 5V DC (must be voltage-free for contact making) Multiplication / division of contacts 1 / 2 / 4 / 8 / 16 / 32 / 64 Load for 0(4)...20 ma input 150 Ohm Voltage at level connection 5V DC (level probe w. break contact for alarm empty Alarm relay, voltage-free changeover contact 250V AC, 2.5 A or 30V DC, 2.5A Remote pump switchoff by voltage-free break contact (on site) Max. admissible ambient temperature 40 C Digital display 3-digit display for stroke frequency and level state LEDs for functional display, 3 off green = in operation, red = trouble, green = external control Pressure-sensitive keypad 4 keys for programming and operation Weight 0.8 kg * if ports protected by caps or with serial plug-in connectors. Operating panel 1a 1b 1c a 1b 1c Check display "in operation" Check display "external control" Check display "alarm" 2 Remote switchoff 3 Level connection 4 External control 5 Selection of operating mode 6 Setting of values 7 ON /OFF switch 8 Display
4 MB / 4 Dimensions MEMDOS E / DX Type A B C
5 MB / 5 Dimensions MEMDOS E / DX Types A B C D E approx. 469 DX approx. 486 E approx. 469 DX approx. 486
6 MB / 6 Performance curves MEMDOS The flow rate depends on the viscosity of the medium and the hydraulic installation conditions. The performance curves refer to water at 20 C and a suction lift of 0.5m. Output valid for 50 Hz; at 60 Hz higher by factor 1.2.
7 MB / 7
8 MB / 8 Performance MEMDOS E / DX The flow rate depends on the viscosity of the medium and the hydraulic installation conditions. The performance curves refer to water at 20 C and a suction lift of 0.5m. X
9 MB / 9 Installation example Legend 1 Metering pump E / DX MB Suction line MB Electric agitator MB Tank MB Relief valve MB Diaphragm shutoff valve MB Injection nozzle MB Pulsation dampener MB Switchbox upon request 1 Pump type manual E DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX Selection tables In order to be able to offer the user a variety of pumps, these have been divided into the main functional groups. They can thus be assembled according to the user s individual requirements. 1 Drive 2 Motor 3 Head 4 Valves 5 Connections Control unit The numbers on the pump drawing refer to the relevant selection tables.
10 MB / 10 Pump type Motor type Transformation Pump type Part No. E / DX Three-phase current 55:1 E / 230 V, Bg 63 30:1 E ,05 kw, 50 Hz, IP 55, ISO-F 15:1 E15 / :1 E :1 E / 230 V, Bg 63 55:1 E4* ,25 kw, 50 Hz, IP 55, ISO-F 30:1 E8* :1 E15* / 50* / :1 E26* / 76 / :1 E25* / 75 / A.C. 55:1 E/DX V, Bg 63 30:1 E/DX ,05 kw, 50 Hz, IP 55, ISO-F 15:1 E/DX :1 E/DX :1 E/DX V, Bg 63 15:1 E/DX50 / ,12 kw, 50 Hz, IP 55, ISO-F 12:1 E/DX76 / :1 E/DX75 / E / DX Three-phase current E / 230 V, Bg ,37 kw, 50 Hz, IP 55, ISO-F A.C. E/DX 230 V, Bg ,25 kw, 50 Hz, IP 55, ISO-F * with frequency converter operation Motor MEMDOS E / DX j6 K ca. 276 M5 4x at peripheral area
11 MB / 11 Motor MEMDOS E / DX Ø 105 Ø 85 3 Ø 70 Pump Diaphragm Head type diameter PVC PVDF PP E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX E / DX Ø 14 k6 4 ca. 249 Pump type E / DX DN 4 E / DX DN 6 E / DX DN 10 Housing material PVC PVDF PVC PP Seal material Viton PTFE PTFE Viton Hypalon AF Viton Hypalon AF Double-ball Suction valve valves Discharge valve Spring-loaded Suction valve valves Discharge valve ,5 2,5
12 MB / 12 5 P ump Part-No. type E / DX D N Fig. D di da L PVC PP PVDF A G 5/ E A A A B C C D - G 1/ E E A G 3/ A A B B1 d C G 3/ C C D - G 1/ D1 d20 - G 1/ E C G1 1/ D - G 3/ B C D - G 1/ F C D - G 3/ A B B1 C D D1 E E1 F
13 MB / 13 Order examples Case 1 45 l/h of flocculant of watery consistency are to be metered into a settling tank. The level of the supply tank is maximally 3m above the pump. Metering takes place against free discharge. Solution: PVC, Hypalon, EPDM and glass are resistant materials. Due to the positive supply (from above) and the free discharge (no backpressure), a backpressure valve must be fitted. A MEMDOS E, size I, l/h, with three-phase motor is chosen. The pump consists of the following modules: Drive Three-phase current PVC metering head PVC double-ball valves, Hypalon Suction valve Discharge valve Connections Suction side Discharge Side Case l/h of a coloring substance are to be added proportionally to a process line. An analog ma signal or 6000 contacts per hour are available as flow-proportional signal. The system pressure is 6 bar. No aggressive medium is used. The viscosity is, however, 500 mpa*s. Solution: PVC, Hypalon, EPDM and glass are resistant materials. As the viscosity exceeds 400 mpa*s, spring-loaded valves are required. Due to the type of control, a MEMDOS DX 200 ( l/h) is chosen. As the pump is able to carry out 95 strokes/min., 5700 metering strokes are maximally possible per hour. This is insufficient compared to the incoming Therefore the pump is set so that it is activated by the analog signal. It consists of the following modules Drive A.C PP metering head PP spring-loaded valves, Hypalon Suction valve Discharge valve Connections Suction side Discharge Side Note: If only contact making can be used, the pump must selected as follows: With the help of pulse divsion function, divisor 2, the aforementioned pump would have to carry out max. 6000/2=3000 strokes. As a result the flow rate would be reduced to 208/5700x3000=109 l/h < 150 l/h. In this case, a MEMDOS DX 300 with 292 l/h at 8 bar would be appropriate, which can process 5700 contacts with its possible strokes per minute. With 3000 contacts the pump delivers 292/5700x3000=154 l/h by 8 bar and about 10 % more by 6 bar. A precise adjustment is possible using the stroke length adjustment knob.
14 MB / 15 General Metering pumps which are used as final control element in automatic control loops or controlled systems are equipped with electrical servomotors allowing to adjust the stroke length by means of sensing contacts or controllers with relay output. Such pumps are identified by suffixing the letters ATE to the type designation: Example: E ATE The non-linearity of the performance curves of diaphragm metering pumps is maintained despite the linear mechanics of the stroke adjustment. For this reason, the performance curves of the metering pump must be taken into account in control systems without feedback of the metered result (proportional metering). Technical data Pump type Memdos E Memdos E Servomotor KNG 2.60 KNG 2.60 ST KNG KNG ST Part No Mechanical design Reversible servomotor with self-locking step-down gear. Connections led out via cables (900 mm). Angle of rotation limited by two internal limit position switches. Use For controllers with For controllers with For controllers with For controllers with switching output (3- continuous output switching output (3- continuous output point step control). 0/2...10Vor 0/ ma point step control). 0/2...10V or 0/4...20mA (switchable). (switchable) Torque 8 Nm 10 Nm Voltage 230VAC +/-10% 24 VAC +/-10% 230 VAC +/-10% 24 VAC +/-10% 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Input impedance at voltage input 100 kohm 100 kohm Burden at current input Ohm Ohm Power consumption 4 VA 7.5 VA 4 VA 7.5 VA Regulating time / bevel 180s (150s) / 270 = % 360s (300s) / 270 = % Load limit of the voltage output max. 0.5 A max. 0.5 A Position repeating Ohm 0-10 VDC for control Ohm 0-10 VDC for control signal for remote 2Watt at tu=40 C with V and 2Watt at tu=40 C with V and display max ma ma VDC for control VDC for control with V and with V and ma ma. Type of protection IP 54 Ambient temperature -10 to +60 C Weight 0.6 kg Diaphragm Metering Pump MEMDOS E - ATE
15 MB / 16 Dimensions E L A L 90 B 97 C Dimension L see MB / 12 Dimensions E L A L 130 B 121,5 C Dimension L see MB / 12 d9 130 ca. 376 d ca ca. 80 ca. 184 Type A B C , ,5 ca. 98 ca. 203 Type A B C E ,5 317 E ,5 320 Diaphragm Metering Pump MEMDOS E - ATE
16 MB / 17 Wiring diagram KNG 2.60 / L1 N Wiring diagram KNG 2.60 / ST N 24V AC L1 OPEN 3 CLOSED 1 1 0/2...10V DC-,0/4...20mA 0/2...10V DC 2 2 Actuation through sensors, switches, controller contacts, etc Setting of coding switch KNG 2.60 / 2120 ST x = Any switch position 1. Voltage input 0-10V at terminals 1 and 4 ON x x x x x x OFF x x x x x x V at terminals 1 and 4 ON x x x x x x OFF x x x x x x Current input 0-20 ma at terminals 1 and 4 ON x x x x x x OFF x x x x x x ma et terminals 1 and 4 ON x x x x x x OFF x x x x x x Direction of rotation (default setting) ON x x x x x x x OFF x x x x x x x ON x x x x x x x OFF x x x x x x x Output voltage 0-10V at terminals 1 and 3 ON x x x OFF x x x V at terminals 1 and 3 ON x x x OFF x x x Diaphragm Metering Pump MEMDOS E - ATE
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range
Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
Radial piston pumps type R and RG
Radial piston pumps type R and RG Operating pressure p max = 700 bar Delivery flow Q max = 91.2 lpm (at 1450 rpm) Geometric displacement V g max = 64.2 cm 3 /rev. 1. General Motor pumps and hydraulic power
DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.
LEAKVALVE: HIGHLIGHTS The core of this valve is a diaphragm in stainless steel 316L, gold plated. Robust, it cannot be damaged with any normal methods. The dead volume is kept as small as possible. There
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
Solenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Butterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
MANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value
Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be
3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
Electro-Pneumatic Bus Door Control Mechanism
Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations
Valve Remote Control Systems Centralized Hydraulics for marine vessels and offshore installations PLEIGER MASCHINENBAU _Hydraulic Actuators STK _Power Packs _Solenoid Valve Cabinet and Process Control
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
Data sheet ECC 12 and 22
Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).
DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP
SKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Series description: Wilo-Yonos MAXO-D
ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: [email protected] 1115 4G
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive
Series description: Wilo-Star-Z
H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Excellence through Versatility
Metering Pumps Excellence through Versatility Liquid Metronics Incorporated has been providing quality products and service to the water treatment industry worldwide for over 25 years. Leading the way
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.
IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Operating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
Guidelines for operation of minimum flow control valves
Guidelines for operation of minimum flow control valves Holter Regelarmaturen GmbH & Co KG Helleforthstr. 58-60 D-33758 Schloß Holte-Stukenbrock 05/2005 List of contents I. Minimum flow control valves...
FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS
4 AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10.0 Bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from polyacetal 2 bodies and above manufactured from polymade and glass fibre 3/4 to
225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
Introduction to Process Control Actuators
1 Introduction to Process Control Actuators Actuators are the final elements in a control system. They receive a low power command signal and energy input to amplify the command signal as appropriate to
Series description: Wilo-Yonos MAXO
16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection
Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators
Favorable Variety Whether rotary or linear with pneumatic, electric, and hydraulic valve actuators from ARCA Regler GmbH, you always have the right solution at hand. ARCA s comprehensive product portfolio
CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7
Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: [email protected] Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables
Condensate water pump with neutralisation system
Pumps for fuel oil and gas boiler Condensate water pump with neutralisation system SK9E/FP8E débit obtenu (l/h) caractéristriques selon la fréquence réglée performances avec une hauteur d aspiration de
Hydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
Rotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9
CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5