LCL1/3/8 CONTROLLER OPERATING MANUAL
|
|
|
- Bruce Pope
- 9 years ago
- Views:
Transcription
1 This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment with radioactive chemicals! LCL1/3/8 CONTROLLER OPERATING MANUAL Read carefully! ENGLISH Version R
2 LCL1/3/8 series instruments comply with the following European regulations: EN : 1995, EN55014, EN /2, EN /2, EN6055-2, EN60555,3 Based on directive CEE 73/23 c 93/68 (DBT Low voltage directive) and directive 89/336/CEE (EMC Electromagnetic Compatibility) GENERAL SAFETY GUIDELINES Danger! In emergencies the instrument should be switched off immediately! Disconnect the power cable from the power supply! When using instrument with aggressive chemicals observe the regulations concerning the transport and storage of aggressive fluids! When installing outside European Community, always observe national regulations! Manufacturer is not liable for any unauthorized use or misuse of this product that can cause injury or damage to persons or materials! Caution! Instrument must be accessible at all times for both operating and servicing. Access must not be obstructed in any way! Instrument and accessories must be serviced and repaired by qualified and authorized personnel only! Always read chemical safety datasheet! Always wear protective clothing when handling hazardous or unknown chemicals! 2
3 Index Instrument Description page 4 Electrical Connections page 4 LCL/1 - ECLx Installation page 5 Amperometric cell calibration page 5 HClO Dissociation Curve page 6 Stand by page 6 Delay page 7 Alarm page 7 Set point adjustment page 7 ECLx Cell cleaning/maintenance page 8 Output current signal page 8 Accessories kit page 8 Technical Characteristics page 8 Installation wiring diagrams page 9 3
4 INSTRUMENT DESCRIPTION LCL/1 is an instrument to analyse and control Free chlorine (or Chlorine Residual) into water visualizing mg/l Cl 2 values. LCL/1 controls CL 2 concentration present into the water system by measuring the Hypochlorous Acid-HclO obtained when dosing either Organic chlorine (ex: Isocianuratic Chlorine) or when dosing Inorganic chlorine (ex: Sodium Hypochlorine). LCL/1 can be connected to EMEC amperometric Cl Cell types: ECL/1; ECL/2; ECL3. LCL/1 provides two Set-point independent adjustment and two ON/OFF output; furthermore it features a 0 20 ma output to connect either a chart recorder or for long distance remote control. The 7-segments Display read out enables efficient reading even where environment does not allow easy-clear reading. LCL/1 is enclosed into ABS plastic casing rated IP 65. Casing dimensions are 215x215x125mm and four fixing points ensure steady and safe mounting. Friendly user controls for calibration and adjustment operations are easy to access and protected with a transparent polycarbonate cover with climp-on lock. ELECTRICAL CONNECTIONS TO LCL/1 METER All electrical connections to LCL/1 can be carried out through the internal connector clamp placed at the front bottom of the casing: to access unscrew front bottom cover. A A B B F2 C JP4 SP2 SP1 From left to right are shown the following connections duties: 1 ; 2 - Power Supply 230V mains input 3 ; Out S.P.1 Set Point 1, 230 Vac output (Max 5A resistive) 5 ; Out S.P.2 Set Point 2, 230 Vac output (Max 5A resistive) 7 ; 8 ; 9 - EARTH 10 ; 11 - N.O. (Normally Open) Alarm contact 11 ; 12 - N.C. (Normally Close) Alarm contact 13 (Brown) 12 Vdc ; 14 (Black) Input ; 15 (Blue) ground - SEPR * proximity switch sensor 16 (yellow); 17 (green); 18 (brown); 19 (white) ECLx amperometric chlorine cell 24 (+) ; 25 (-) Current Out * 0 20mA current output (upon request available: 4-20 ma, etc.) 20; 21; 22; 23; No connected A OUTPUTS S.P.1/2 FUSE protection fuse for whole unit (2A T 5x20) B INSTRUMENT FUSE instrument fuse (0,3A T5x20) C ALARM FUSE connections clamp fuse (0,3A T5x20) 4
5 JP1 Jumper Set-Point 1 configuration: selecting LCL/1 working field (Chlorating/De-Chlorating) JP2 Jumper Set-Point 2 configuration: selecting LCL/1 working field (Chlorating/De-Chlorating) JP3 Jumper Automatic / Manual Probe temperature JP4 Jumper to set instrument activating time delay LCL/1 - ECL1/ECL2/ECL3 INSTALLATION To install the instrument and Cl cell proceed as follow : - install LCL/1 and EMEC electrode holder PEF2 onto the wall or vertical support ensuring that electrode holder is placed vertically - install Chlorine cell ECL1 or ECL2 or ECL3 onto the wall or any vertical support ensuring that the two cell electrodes are placed horizontally: copper electrode at the right side (blue wire) and platinum electrode at left (red wire) - connect electrode holder PEF2 inlet to the system to be treated (to prevent or reduce maintenance operation install a water filter, 80 micron, ahead of electrode holder). Connect PEF2 inlet (top position) to amperometric cell using hydraulic connections provided with the instrument. Connect Cell outlet to drain or compensation tank. If system pressure is not strong for incoming water flow into the Cell, connect Cell outlet to the system boosting pump suction side. - install proximity switch SEPR into threaded fitting (PEF left side) and connect three wires as in page 4. - turn LCL/1 On; when starting up the instrument, Delay funtion red Led will wink activating this function: dosing operations will start after selected time delay thus allowing water in for a correct measurement and for correct polarization of all connected electrodes (see paragraph Delay ). For a correct use of LCL/1 install ahead of amperometric cell ECL1/2/3 a flow stabilizer (max 50 l/h max) or Emec electrode holder model PEF2. ECL1/ECL2/ECL3 CHLORINE CELL CALIBRATION Once instrument is correctly installed, to calibrate ECL1/2/3 amperometric chlorine cell, proceed as follow: - unscrew bottom protection cap (do not touch or remove the membrane!) - fill the membrane cap with electrolyte keeping electrod in vertical position then reassemble the cell avoiding that hands come in contacts metal parts. If electrolyte drips out when putting cap back, is not a problem. - connect Cell wires to LCL/1 internal clamp connector as in page 4 - run water from system to be treated into Cell and PEF2 and regulate incoming flow rate to about 30 l/h: adjust flow rate by means of PEF2 flux meter screw until floater top reaches PEF2 indicated level. - remove all air bubbles into the Cell to prevent reading error. - run water flow into Cell ECL1/2/3 for approximate 30 minute. - shut water flow into Cell and wait to stabilize the reading: in this conditions instrument must read 0,00 mg/l of free chlorine. - Adjust the Zero by means of front panel controls potentiometer using a screwdriver until display shows 00,00 mg/l - Adjust the Zero, front panel controls, until display shows 00,00 mg/l - re-open water and take water sample at the electrode holder outlet, analyze it using colorimetric system (type DPD1) or by means of photometer. 5
6 - with screwdriver adjust GAIN front panel potentiometer until display shows same value obtained with colorimetric analysis. - repeat amperometric cell calibration few times during initial days of operation or repeat calibration every time ph changes into the water system to be treated (refer to Dissociation Curve HClO herein below ). %HClO HClO Dissociation Curve ,2 6,4 6,6 6,8 7 7,2 7,4 7,6 7,8 8 8,2 8,4 ph ECL3 and ECL8 CALIBRATION Use the same procedure as for ECL1 calibration but note that the Dissociation Curve doesn t fit for this probes. Starting from a value of 7pH into reading solution, the probe will reduce the reading value by 10% for every single ph read. For ECL3 probe (free chlorine) use a DPD1 system. For ECL8 probe (total chlorine) use a DPD4 system. Maximum concentration of stabilizer (isocianuric acid) allowed by probe: 200mg/l. STAND-BY Stand-By is activated automatically when water is not running through the Chlorine Cell: in this condition (No incoming water) Cl Cell will surely generate a reading error causing the dosing pump to continue injecting chlorine consequently increasing the chlorine residual value in respect of the requirements. Furthermore this function is suitable when operator wishes to shut off the system for maintenance purpose (ex. clean pool filters) but keeping instrument measurement active. The automatic Stand-By function is possible by means of the proximity switch SEPR connected to the instrument internal clamp connector with three wires: brown/blue/black. When front panel Stand-By red Led is On, outputs S.P.1-S.P.2 are deactivated whilst instrument measurement is constant. Once incoming water flow is restored into the Cell, Delay red Led is winking activating this function: dosing operations will start after selected time delay thus allowing water into the cell for correct measurement. Outputs S.P.1-S.P.2 are active once selected delay time cycle is over. To select the DELAY time, position jumpers JP4-7 and JP4-8 as shown in following paragraph. Stand-By can also be activated by means of a voltage free N.O. contact, to apply to connectors This control is available from the booster pump multi-pole auxiliary contact or from a relay multi-pole. 6
7 DELAY Delay function is operational when turning ON the instrument or after Stand-By cycle and automatically deactivates all outputs allowing a correct polarization of all connected electrodes. Timing selection is available positioning jumper JP4 as follows: JP4-4 JP4-2 JP4-3 JP4-5 Delay JP4-4 C O C O JP4-5 C C O O Time Alarm JP4-2 C C O O JP4-3 C O C O Time Escluso C(Close) O(Open) ALARM This function is designed to give an alarm when additive concentration into the system has not reached the required Set-point after the selected Alarm time period. Time ranges: 15 minutes (most common), 30 or 60 minutes. When the Alarm is activated, the operator should acknowledge that dosing pump is either not injecting or additive tank is empty or concentration is too low. To make Alarm function operative connect an alarm unit (light, sound, etc.) to LCL/4 internal clamp connectors relay output 10, 11, 12 (Voltage Free). To select Alarm time period position Jumpers JP4 and JP5 as shown in table herein below. Alarm function will activate also when LCL/1 meter is in Stand-By condition (water is not running through electrode holder) and will deactivate once Delay time period is over. SET-POINT ADJUSTMENT To read selected Set-Point, press the button below the knob Set-Point 1 or 2 : to modify turn the knob Set-Point 1 or 2 while pressing the button below until the display shows required Set-Point. When Set-point yellow Led is lit, correspondent output is active and on either one of connectors 230 Out S.P.1 or S.P. 2 there is power supply to connect dosing pump or other equipment. When yellow Led is lit, free chlorine value shown on display is higher (or lower) than Set-Point 1 or 2 previously selected. To change instrument setting to higher (or lower) values then the one selected, a new configuration of the internal jumper is needed. To access to internal jumper, remove front cover, locate the jumpers, follow diagram here below: ACTIVE OUTPUT SETPOINT VALUE> DISPLAY READING CHLORINE DOSING ACTIVE OUTPUT SETPOINT VALUE< DISPLAY READING DE-CHLORATING DOSING 7
8 ECLX CELL CLEANING AND MAINTENANCE After a certain period of operation (6 months/1 year and according to the water quality parameters), or whenever calibration is not longer possible, chlorine cell must be cleaned. To carry out electrodes cleaning refer to instructions enclosed with Cell. - if cleaning operation was succesfull, after approximate 24 hours measurement will stabilize in contrary change the electrodes. OUTPUT CURRENT On the internal connector clamp, connectors showing Current Out provide a proportional current signal shown on the display as: 0 10,00 mg/l Cl 2 = 0 20mA ; 4 20mA Max external input impedance: 330 Ohm. Instrument tag shows output current value set at the factory The ma current signal has not galvanic isolation. Upon request galvanic isolation available. ACCESSORY KIT N. 4 Dibbles ø6 N. 4 Self threading screws 4.5x40 N. 1 Instruction booklet N. 1 Set-Point 1 or 2 fuse (2A T 5x20) N. 2 Fuses for instrument and contact protection (0,3A T5x20) LCL1 TECHNICAL CHARACTERISTICS Power Supply : 230 Vac ± 10% Measuring range: 0 10,00 Cl 2 Resolution: ± 0,01 mg/l Input Impedance: 1 kohm Zero adjustment: ±1 mg/l Hysteresis set-point : ± 0,1 mg/l Power consumption: 3 Watt Weight: 3 Kg Protection rating: IP65 Environmental working temperature: 0 50 C 8 Technical features, data sheets and drawing herein shown are subject to modifications without advice from Manufacturer.
9 9
10 10
11 11
12 When dismantling an instrument please separate material types and send them according to local recycling disposal requirements. We appreciate your efforts in supporting your local Recycle Environmental Program. Working together we ll form an active union to assure the world s invaluable resources are conserved. 12
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
ATL Fuel Level Sender Probes
T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation
The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation Introduction The importance of keeping cooling tower water in proper chemical
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00
Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu WARNINGS Read carefully
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
ExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
Technical Update TAA.TU.11093 Rev. 1
http://www.gambro.com/en/usa_tech/ 800-525-2623 303-222-6500 Technical Update TAA.TU.11093 Rev. 1 Effective: 05 APR 2013 CO# 13084 Product: Subject: From: Phoenix Dialysis System Required Electrical Safety
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction
Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)
SECURITY SYSTEM ADP-CAN
INSTALLATION INSTRUCTION SECURITY SYSTEM ADP-CAN Introduction Motorcar security system ADP-CAN is for motorcars provided with CAN net. It is for the work with the motorcar factory security systems or remote
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions
Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
SOLAR POWER - THE NEW WAY TO RV!
IMPORTANT! - YOU'RE SOLAR READY SOLAR POWER - THE NEW WAY TO RV! Your RV is PRE-WIRED for SOLAR POWER! Benefits of Solar Zamp Solar Portable Solar Kit Maximize Battery Life Electrical Independence Green,
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
ELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Pro Logic Version 4.10. Diagnostics Manual
Pro Logic Version 4.10 Diagnostics Manual Turbo Cell & Control Electronics 2009 Hayward Industries Table of Contents Important safety instructions Pg. 1 No Cell Power 1 & No Cell Power 2 Pg. 2 No Cell
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS
MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS Measuring and Controlling Equipment ensuring required water quality in public pools. This is fully automatic measuring and controlling equipment with
Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
COMPALARM AP GENERAL MAIN FEATURES
GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System
ELITE-L Series ELITE - Low Voltage / Dry contact Remote Control System Applications Garden Lighting Pond pumps Remote outdoor Switching Access control Industrial control Features 4 switched channels 1000W
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
Milwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
OPERATING INSTRUCTIONS
PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3
BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW
WARNING CARTON INVENTORY CAUTION with: Charger, Cable 15', Fuses (2), Battery Strap and Strain Relief (2) Model SOLBBOX 12V Battery Not Included AVERTISSEMENT ATTENTION DC Power Adapter 12Vdc to 32Vdc
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011
Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
Model 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable
Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10 Programmable thermostat Thermostat programmable Termostato programable Read and save these instructions. Veuillez lire le mode d
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Operating instructions Capacitive sensors
Operating instructions Capacitive sensors UK 700 / 00 0 / 009 Contents Safety instructions Functions and features Installation. Notes on flush and non-flush installation Electrical connection. Wiring.
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information
London Electronics Limited Warren Court, Chicksands, Shefford, Bedfordshire SG17 5QB Tel +44(0)1462-850967 Fax +44(0)1462-850968 www.london-electronics.com [email protected] Ethernet to RS232
Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13
CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter
ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
Cable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
SX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.
MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.
PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual
Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6 User s manual Index Safety Warnings... 2 1 Introduction... 3 2 General Characteristics... 4 3 Receipt and site selection... 4 4 EXTERNAL
User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending
User Guide ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens Patent Pending Getting Started Remove the cap from the bottom of the ExStik TM to expose the electrode bulb and reference
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
General Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
INTRIC E. D811285 13-11-00 Vers. 02 SELF-LEARNING ROLLING-CODE EXTERNAL RECEIVER
D811285 13-11-00 Vers. 02 SELF-LEARNING ROLLING-CODE EXTERNAL RECEIVER 360 1) GENERAL OUTLINE Thank you for buying this product, our company is sure that you will be more than satisfied with the performance
Instruction Manual Differential Pressure Transmitter
DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
Installation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
Manual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
PIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer