1 Innovations 2008 There's a lot to discover... Frank Gloger, KNX Conference for Training Centers
2 Your whole home in your pocket
3 KNX Internet controller IC1-V2 REG-K, Compact, space-saving housing (6 HP) 25% greater processor power Connection via DSL possible, control via: Smartphone, PDA PC or touch-panel Video transmission via standard webcam (LAN) Up to 8 webcams (LAN) can be integrated Low power consumption in standby mode Complete Merten@Home configuration
4 KNX power supply REG-K The right solution every time New building of Conservative Medical Clinic of the Johannes Gutenberg University Mainz
5 KNX power supply REG-K The right solution every time 160 ma, 320 ma and 640 ma with and without emergency input Power supplies with emergency power input can be connected to the new REG emergency supply Uniform size 4 HP, all connections via plug-in terminals Reset button instead of switch -> simple and safe line reset KNX power supply 160 ma, art. no ma, art. no KNX power supply with emergency power supply 640 ma, art. no ma, art. no ma, art. no ma, art. no
6 KNX power supply REG-K The perfect emergency power supply New: power supply with emergency power input New: emergency power supply with LED and signalling contacts for Mains voltage Error warning Battery operation Binary input for reporting on the KNX Sealed lead battery
7 KNX Basic weather station All weather data under one umbrella A multi-talented genius - Processes wind, rain, brightness and temperature measurements Weather station for small commercial buildings and detached houses Direct evaluation in the device Power supply from bus voltage 4 universal channels 3 sunshade channels (especially for blind and roller shutter applications) Integrated heating unit to dry the rain sensor (230 V connection)
8 KNX brightness and temperature sensor Perceptibly more efficient 2 weather values can be recorded with a single device and sent to the bus All brightness thresholds can be programmed on site if necessary 4 channels each with 2 logically linked weather conditions 1 sunshade channel
9 KNX fan coil actuator REG-K Perfect climate with KNX Actuator for 1- to 3-speed control of air convectors (fan coil) Suitable for operation on KNX Fan coil actuator specifically controls the fan coil with up to 3 fan speeds and the heating/cooling valve Can be controlled and actuated by means of multi-function pushbuttons featuring room temperature controllers
10 KNX room thermostat UP/PI with 4-gang push-button interface More energy-efficient control Can be used for single-room temperature control Available in System M and System Design Integrated bus coupler Integrated 4-gang push-button interface Input 1 can be used to connect a temperature sensor 2 inputs can be set as outputs (max. 0.8 ma)
11 TeleController Plus REG-K Always there when you're away Fault signalling and remote switching by own voice message, text message, fax and ebuilt-in bus interface module which can be used to manage 20 KNX device functions (1 bit, 1 byte and 2 byte values can be set) Option of switching bus devices with 10 KNX device functions Transmission of alarm calls to freely programmable numbers with 10 KNX device functions Six conventional devices can be switched on/off via switch outputs
12 KNX timer REG-K Built-in punctuality as standard Time transmitter for synchronising bus devices The time transmitter is a clock which sends the time and date to the bus This clock can be set with the DCF signal or via the bus The time data can be sent both cyclically and on request Time zones and summer/winter time can be programmed flexibly Integrated lithium battery so that operation continues in case of a power failure
13 New Devices for Energysaveing KNX ARGUS-Presence with light control and IR-receiver KNX switch actuators with manual mode and current detection
14 ARGUS Presence Overview KNX ARGUS-Presence Basic 2 movement / presence blocks Normal mode (no Master/Slave) 4 movement sensors, commonly adjustable KNX ARGUS-Presence 180/2,20m FM 5 movement / presence blocks Normal, master, slave and monitoring mode 2 movement sensors, separately adjustable KNX ARGUS-Presence 4 movement sensors separately adjustable, others like prev. device KNX ARGUS-Presence with light control and IR-receiver Like previous device and additionally: Light control IR-receiver (10 x internal + 10 x KNX)
15 ARGUS Präsenz Overview of the functionality Light controller Actual value correction ionality Funct IR-receiver Master/Slave parameter Sector oriented settings Outputs per block Presence block External brightness value Self-adjusting staircase time Basic Pres. 2,20m FM e Presenc Pres. w ith contr olling Product value
16 ARGUS Presence Sector-orientated settings of movement sensors For each block, sectors A-D can be enabled or disabled separately Default setting: all sectors are used in parallel for movement detection Application examples In one sector there is an increased air circulation: This can cause undesired movement impulses Solution: switch off or reduce sensitivity of the sector The desk is located in sector B and sector D is monitoring the entrance The range of sector D can be reduced to not trigger room functions (blocks) from the corridor Sector D can be used with full range in a separate block to control the corridor lighting
17 ARGUS Presence with light control and IR-receiver Overview Five presence/movement blocks like the presence detector, and additionally: IR-receiver 10 channels for configuration Brightness threshold, times and range 10 channels for KNX-functions Switching, dimming, blinds, scenes, edges function (long/short operation) Light control 4 bit or 1 byte control Two light groups can be controlled with displaced values Switching additional lighting
18 ARGUS Presence with light control and IR-receiver Advantages of IR control Installation site IR receiver is located on the ceiling -> Optimal reception Not blocked by furniture later Full remote control - max.10 channels Toggling, switching Pulse edges 1 bit, 1 byte, 2 byte Dimming, blind, scene Setting control - max. 10 channels Increase/decrease range Brightness thresholds or actual value Increase/decrease staircase timer
19 CONNECT radio universal remote control Infrared control of up to 5 AV devices Remote control of all Merten IR components Individual names for the rooms and groups can be assigned and shown on the LCD display Reliable lighting and blind control via the Merten CONNECT radio system Configuration with the Easy CONNECT method: connect up to 5 devices with one another without software Configuration with the Easy Tool method: more than 5 devices using the CONNECT radio configuration tool Scene control of 3 scenes per room Individual programming of Merten CONNECT radio push-buttons
20 KNX switch actuators with manual mode and current detection 2-gang, 4-gang, 8-gang, 12-gang Integrated current detection, which measures the load current on each channel Operating hours counter Switch-on counter Power meter Nominal current 16A All switch outputs can be operated with manual switches Real status feedback function Even in manual mode the actuator transmits the current status
21 KNX switch actuators with manual mode and current detection discover your energy-saveing potential! determination/monitoring of the switch on time and enery volume e.g.: hotwater devices electro kitchen stove
22 Thank you for your time and attention!
Product data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System
Audio Audio actuator 4fold 0531 00 Audio actuator 4fold Audio actuator mono Audio actuator stereo Communication Infrared 0588.. IR converter IR transmission/reception C00701 Radio 0868 00 Radio-instabus
More informationThe ABB i-bus KNX Room Master Concept Your first step into the KNX world
The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,
More informationUnica for KNX system 226
Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from
More informationB.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
More informationInwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
More informationPRODUCT MANUAL. InZennio Z38i. KNX Touch Panel ZN1VI-TP38i. Program version: 2.2 Manual edition: a
PRODUCT MANUAL InZennio Z38i KNX Touch Panel ZN1VI-TP38i Program version: 2.2 Manual edition: a INDEX Document updates... 3 1. Introduction... 4 1.1. InZennio Z38i... 4 1.2. Installation... 5 2. Configuration...
More informationTebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
More informationHow To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
More informationPush button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
More informationELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com
Aus- und Weiterbildung GmbH Home and Building Control KNX / EIB www.elabo-ts.com Design and commissioning of KNX/EIB systems www.elabo-ts.com Hardware page 2-5 Software page 6-9 Projects page 10-15 LOGO!
More informationABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2
Product Manual ABB i-bus EIB US/U 4.2 US/U 2.2 Intelligent Installation Systems Intelligent and limitless Contents Page 1 General............................................. 3 1.1 Product and functional
More informationABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
More informationMovement/monitoring 1307/1.0 (6325xx)
/monitoring 1307/1.0 (6325xx) General In the following the device will be referred to as the movement detector. The movement block will only switch off when there is no more movement in front of the device
More informationInwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
More informationPRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a
PRODUCT MANUAL IRSC IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC Program version: 5.14 Manual edition: 5.14_a INDEX Document updates... 3 1. Introduction... 4 1.1. IRSC controller... 4 1.2. Installation...
More informationPassion for KNX innovation
Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can
More informationTechnical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
More informationTEDDINGTON. Intuitive control. TLC 700 The multifunctional controller
Intuitive control TLC 700 The multifunctional controller TLC 700 The intelligent controller for complex systems TEDDINGTON As easy as Teddington air curtain systems are the ultimate when it comes to the
More informationSchneider Electric and Energy Efficiency
1 Energy Efficiency in Residential How to save Energy in Home Control applications? Jean-Jacques Poubeau Schneider Electric and Energy Efficiency Energy Efficiency (E²) is an important concern for our
More informationLGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com
More informationHOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW
OVERVIEW The purpose of this this specification document is to define the main features and guide lines for the Hotel Room Management System, which includes Access Control, Guest Management, & Building
More informationLight scene push button 8gang comfort flush-mounted 751688xx
751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional
More informationBasics of Dimming. ISC Learning Centre
ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer
More informationExamples of installations
Examples of installations Video door entry, automation and burglar alarm Row house The example shows the integration of the automation and burglar alarm system with the Sound System video door entry system,
More informationPRESENCE DETECTOR PD-C360i/24 KNX ECO (EP10425844)
In the Master function, the remote control entries will be acknowledged as follows: acknowledged 3 x with the red LED In the Slave function, each detection is acknowledged 2 x with the green LED. 6 TEST
More informationPassion for Innovation
Passion for Innovation A Complete Solution Hardware All the Alveo servers are designed and optimized to manage the home automation system. They arebuilt for continuous operation with fanless processing
More informationRadio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light
Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light In this issue, we would like to present the EnOcean radio sensor module STM 110 in more detail. The module
More informationMy home. Mobile phone application. Instructions for use and installation. For DELTA DORE GSM transmitters and transmitter control units.
My home Mobile phone application For DELTA DORE GSM transmitters and transmitter control units Instructions for use and installation My home Alarm Heating Bedroom Dining room Kitchen Garage Absence Messages
More informationFSLIMRF05-10 - 15-20 - 25
1. INTRODUCTION FSLIMRF is a fully wireless, battery-powered infrared beam barrier for the protection of doors and windows with alarm radio transmission. The barrier is made up of two aluminium sections
More informationDALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com
Gateway KNX-DALI DALIX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com
More informationEKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch
Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com
More informationABB i-bus EIB Logic Module LM/S 1.1
Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...
More informationABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
More informationABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
More informationPush button 3gang standard flush-mounted 751633xx
Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard
More informationcontents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
More informationABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
More informationF454. Web Server. User Manual 05/12-01 PC
F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with
More informationKNX Lighting Control System
KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting
More informationTYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel
Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : deltadore@deltadore.com Unit compliant with the requirements of directives:
More informationPower Line Carrier technology
Power Line Carrier technology To be used in new or renovated traditional installation (L+ required) up to 00 m SIMPLE TO ISTLL FOR MXIMUM COMFORT PLC technology, which systematically includes neutral,
More information1. Learn about the 555 timer integrated circuit and applications 2. Apply the 555 timer to build an infrared (IR) transmitter and receiver
Electronics Exercise 2: The 555 Timer and its Applications Mechatronics Instructional Laboratory Woodruff School of Mechanical Engineering Georgia Institute of Technology Lab Director: I. Charles Ume,
More informationOperating instructions. RCD flat 4-fold, 6-fold
Operating instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Observe the current accident prevention regulations. Failure to observe the
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationGuest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries. www.lonix.com
Guest Room Controls & Monitoring System Integrated Solution for Hotels Southern Countries www.lonix.com GUEST ROOM CONTROLS & MONITORING SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3 1.2 USER
More informationABB i-bus KNX i-bus Tool Product Information
ABB i-bus KNX i-bus Tool Product Information A professional Service Tool for System Integrators ABB presents a fully new and innovative software concept with the i-bus Tool. It supports system integrators
More informationHyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
More informationABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1
Product Manual ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M 2.6.1 ES/M 2.230.1, ES/M 2.24.1 Intelligent Installation Systems This manual describes the function of the Switch
More informationThe application is now available in 8 languages. (German, English, French, Spanish, Italian, Russian, Dutch, Polish)
Product: Room Master, Premium Type: RM/S 2.1 Current application program: Room Master, Premium/2.5a ======================================================================================= to: Room Master,
More informationHighly flexible the right KNX/DALI gateway for every requirement
The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with
More informationBusch-Watchdog Presence EIB Type: 6131-74-102-500
Type: 6131-74-102-500 Contents Technical data 2-2 Application programs (List) 2-3 Circuit diagrams 2-3 in combination with Bus coupler FM (6120-102): Switch Value Cyclic Monitoring /3 2-4 Switch Value
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationConventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
More informationDC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
More informationLight-Manager Air Quickstart Guide
media Light-Manager Air Quickstart Guide Overview and scope of delivery Thank you for choosing the Light-Manager Air. The Light-Manager is the control center for your wireless home automation. For this
More informationSoftstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1
Softstarters Type PSTX Fieldbus communication, Built-in Modbus RTU 1SFC132089M0201 April 2015 1SFC132089M0201 1 1 Modbus RTU The Modbus protocol is a fieldbus protocol that provides full control and status
More informationControls for fan coil units and cassettes
Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11
More informationSigma Control PC INSIDE. 97 psi 187 F R on load
Sigma Control PC INSIDE 97 psi 187 F R on load Innovation Sigma Control with a PC inside At Kaeser, we pride ourselves on being the world s leading innovator in air system technology. Over twenty-five
More informationKNX System Principles
Application Module Bus Transceiver KNX b a T1 C1 T2 Left II Left On Left II Right Off Left X Left Off Left X Right On Left II Left On Left II Right Off Left X Left Off Left X Right On c b a c E2 Bus Cable
More informationHeating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T
Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T HMG 6 T 4930240 HME 6 T 4930245 HM 12 T 4940245 Updated: Dec-14 (subject to change) Page 1 of 61 Contents 1 Contents 2 FUNCTIONAL
More informationIntegrated Building Management and Security System. Building Automation & Security. www.coba-group.com
Integrated Building Management and Security System Building Automation & Security www.coba-group.com INTEGRATED BUILDING MANAGEMENT AND SECURITY SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3
More informationKNX Gateway RGK02-5023E-01
KNX Gateway RGK02-5023E-01 Table of contents Page 1 General Information 1.1 Technical data 5 1.2. Intended Use 6 1.3 Specifications 6 1.4 Compatibility 6 1.5 Scope of delivery 6 2 Information about the
More informationWireless Home Security System
Wireless Home Security System Group: D14 Members: Vaibhav Singh (05D07026) Abhishek Tiwari (05D07028) Sauvik Chowdhury (05D07029) 1. Abstract The project is aimed at designing a low cost and reliable wireless
More informationRVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationGlass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat
KNX/EIB Product documentation Glass sensor 2gang with room thermostat Glass sensor 3gang with room thermostat Issue: 16.01.2009 65750120 Page 1 of 240 KNX/EIB Product documentation Content 1 Product definition...
More informationNew avenues in KNX building automation by integrating self-powered wireless sensors
White Paper KNX and EnOcean New avenues in KNX building automation by integrating self-powered wireless sensors Interaction between self-powered EnOcean sensors and a KNX solution unites the enhanced flexibility
More informationProgramming Logic controllers
Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,
More informationsip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
More informationThe role of home and building control in the smart city. Joost Demarest KNX System & Administration Director
The role of home and building control in the smart city Joost Demarest KNX System & Administration Director Contents The home: this was then, this is now Why home and building control general advantages
More informationBURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
More informationZME_RC2 Z-Wave Remote Control
ZME_RC2 Z-Wave Remote Control Firmware Version : 1.1 Quick Start S This device is a Z-Wave Remote Control with the logical function of a sensor. Push the "Include" button behind the slider on the back
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationShutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
More informationPRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
More informationMy home Mobile phone application
My home Mobile phone application Instructions for use and installation Alarm Heating Bedroom Living room Kitchen Garage Arrived Message Contents 1- Presentation................................................3
More information2.0 System Description
2.0 System Description The wireless alarm system consists of two or more alarm units within a specified range of one another. Each alarm unit employs a radio transceiver, allowing it to communicate with
More informationDAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
More informationTransmitter Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso
Transmitter Speed 1 9 3 5 0 Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso E L S Tr a n s m i t t e r S p e e d M a n u a l 0 2. 0 2. 2 0 1 0 / / 7
More informationFLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
More informationMODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
More informationTechnology of Choice Smart Home and Intelligent Building Control ABB i-bus KNX
Technology of Choice Smart Home and Intelligent Building Control ABB i-bus KNX Contents KNX and ABB i-bus KNX 4 What does KNX stand for? 5 What does KNX do? 6 ABB i-bus KNX 7 Energy efficiency with ABB
More informationZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.
More informationEstação Meteorológica sem fio VEC-STA-003
Estação Meteorológica sem fio VEC-STA-003 The Weatherwise Instruments professional touch-screen weather station is designed for easy everyday use and fits right into any home or office. The indoor base
More informationHeating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX
Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room
More informationApplication Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
More informationUser and installation manual
User and installation manual aquaero 5 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of April 2011 ENGLISH: PAGE 1 DEUTSCH: SEITE 13
More informationF453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
More informationThe following information can be output as speech: status of the teacher / student connection. time markers of the timers.
1 V2 software 1.1 Update from V1 to V2 Additional files must be installed when updating from software version 1 to version 2. In version 2.xx, the volume settings are stored in the model memory. The volume
More informationFlexible home automation
GE Energy Industrial Solutions HabiTEQ TM Flexible home automation for energy efficiency, safety and comfort GE imagination at work In the rhythm of your family Convenience at your fingertips 3 Leaving
More informationKACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data
KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production
More informationConfiguration example: Scene function in the actuator channel in the ETS. 1 Introduction
Introduction Introduction: KNX actuators offer an amazing number of configuration options. Anything from simple feedback function using elapsed-hours meters up to complex scenes can be activated in the
More informationTechnical Manual MDT Rain sensor
9/2012 Technical Manual MDT Rain sensor SCN-RS1R1.01 Technical Manual Rain sensor SCN RS1R1.01 1.1. Settings at the ETS Software Selection at the product database: Manufacturer: MDT Technologies Product
More informationKNX/EIB Product documentation. Master Control. Issue: 23.10.2008 1353702x. Order-No. 7574 00 1X Page 1 of 222
KNX/EIB Product documentation Master Control Issue: 23.10.2008 1353702x Page 1 of 222 KNX/EIB Product documentation Content 1 Product definition... 4 1.1 Product catalogue... 4 1.2 Function... 4 1.3 Accessories...
More informationGSM COMMUNICATORS CATALOGUE
COMMUNICATORS CATALOGUE ( ) 870020/B - 07/2007 - Daitem - ATRAL SYSTEM S.A.S. - R.C.S. Grenoble 311 586 382 The services and product data presented in this document may be modified without prior notice
More informationIDDERO HCx-KNX TOUCH PANELS. User Guide. www.iddero.com 130122-02
IDDERO HCx-KNX TOUCH PANELS User Guide www.iddero.com 130122-02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 OVERVIEW... 3 2.1 System Components... 3 2.2 Basic Operation... 4 2.3 Install Mode... 5 3 USER INTERFACE...
More information2.8. EM24 DIN Energy Analyser
2.8. EM24 DIN Energy Analyser 2.8.1. Multiplexer (transmission of counter values) with EM24 Function: Control and transfer of counter values Application: Registration of energy and operating hours etc.
More informationUsing presence detectors with alarm systems
KNX Presence with light control and IR rart. no. 507Z6354 Merten2005V6309-541-0010/09 KNX Presence with light control and IR r Operating instructions The presence detector also has four movement sensors.
More informationSensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
More informationSCORPION. micron security products
SCORPION 4120 6020 & 8020 USER INSTRUCTIONS Thank you for purchasing a Quality Micron Security Alarm Controller. Micron product is manufactured to exacting quality standards. We understand the importance
More informationAM / FM Tuner + RDS. Model: TU-101. www.pulse-audio.co.uk
AM / FM Tuner + RDS Model: TU-101 www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels within the product
More information