Implementation of HPLC/MS-based methods and solutions for the metabolomic study in new drug discovery
|
|
- Marcia Benson
- 7 years ago
- Views:
Transcription
1 Implementation of HPLC/MS-based methods and solutions for the metabolomic study in new drug discovery Александр Кирилюк, PhD Москва, ул Краснопролетарская, 7 т
2 What is Metabolite ID? Why is it done? Need to determine what happens to a drug after it is ingested Body acts on drug to break it down, make it more polar and therefore more easily eliminated Goal of Metabolite Identification is to find and identify these metabolites Must determine whether these metabolites are toxic, accumulate in the body, or are eliminated harmlessly Metabolism reactions divided into Phase I And Phase II biotransformations Phase I (functionalization reactions) introduces a functional group or exposes a pre-existing functional group via oxidation, hydroxylation, demethylation Phase II (biosynthetic reactions) addition of hydrophilic endogenous species such as glucuronic acid or sulfate Metabolism occurs primarily in the liver To simulate drug metabolism, researchers use human liver microsomes or hepatocytes for in vitro drug metabolism studies AB SCIEX
3 Metabolism Studies: Pharmacokinetics describes what the body does to the drug Absorption Distribution Metabolism (Identification being a subset) Excretion Pharmacodynamics explores what the drug does to the body a whole lot of Qualitative and Quantitative work to understand effects on drug and body AB SCIEX
4 The average time from synthesis of a potential compound to approval of a new drug application (NDA) has increased significantly to years AB SCIEX
5 Metabolism Excretion Pharmacokinetics / Efficacy (CLint) Drug enzymes Metabolites Interact w/ enzyme Inhibition Induction Drug-Drug Interaction (Ki, Km, dose adjustment) Covalent Binding to Macromolecules Adverse Reaction/ Toxicity (Covalent binding; Oxidative stress; Mito dysfunction) Metabolism is the complete set of chemical reactions that occur in living cells (elimination of drugs) AB SCIEX
6 Metabolite Identification has numerous goals through the pipeline Discovery Identification of Metabolites which are formed when a xenobiotic drug enters the body Identification of sites of metabolism on a compound so it can be redesigned in order to prevent toxic or unwanted metabolism Identification of quick-forming metabolites Screening for toxicity (acyl glucaronides, glutathiones) Typically uses in vitro samples relatively clean matrices Speed is of the essence id 80% of metabolites focusing on most prevalent Development First-in-man definitive metabolite study Must conclusively ID all metabolites Monitoring active metabolites in dirty matrices Lower throughput but need to identify everything that can be detected Often use radioisotope labeled drugs to do mass balance studies ensure can account for all of parent drug AB SCIEX
7 Metabolite ID Workflow Relatively simple experiment Customers run sample and control Control is matrix blank (no parent drug dosed/incubated) Sample contains parent drug and any metabolites that are formed Compare sample and control any peaks in sample that are not in control should be metabolites AB SCIEX
8 Metabolite ID Compile a list of all possible metabolites major minor Sample Preparation (in-vitro, in-vivo) Define strategy to identify confirm characterize AB SCIEX
9 in vitro and in vivo Drug Metabolism Systems Common in vitro samples (Our Standards) Hepatocyte: fresh or cryo-preseved Liver S9 fraction Liver microsome Recombinate P450s and other metabolizing enzyms Common in vivo samples (Our Living Systems) Urine: relative clean; dilute and inject Bile: dirty due bile salt; SPE or dilute Feces: Biliary excretes and parent; SPE Plasma: PPT AB SCIEX
10 Strategy for Metabolite Identification Acquire control & sample of interest Find Metabolites Acquire MS/MS Spectra Confirm Metabolites with MS/MS Spectra Report AB SCIEX
11 Current Technologies Used for Small Molecules TripleQuad Quantitation ID with MRM ratio QTRAP Quantitation ID with MRM ratio ID with MS/MS library searching TripleTOF Quantitation ID with accurate mass ID with MS/MS library searching ID for true unknowns Retrospective data processing Increasing confidence in unknown compound identification AB SCIEX
12 Взаимодополняющие решения для метаболомных задач Hardware, Software, & Kits for Non-Targeted and Targeted Workflows TripleTOF 5600 system solutions QTRAP 5500 system solutions Нецелевой Целевой AB SCIEX
13 Сравнение Нецелевого и Целевого Анализа Non-Targeted Analysis MS MS/MS Targeted Analysis - MRM Advantages: Detects any species Disadvantages: Typically lower dynamic range and sensitivity with a separate ID step required Requires sophisticated informatics Advantages: High sensitivity, throughput and dynamic range High quant quality Simplified informatics Disadvantages: Only detects specific species Upfront method development AB SCIEX
14 Общий Подход в Метаболомике Metabolic Profiling Full scan MS MS/MS Targeted Metabolomics QQQ MS/MS Differential Pattern Information ID of Relevant Metabolites ID / Quantitation by MS/MS Metabolite Concentration Shifts Functional Annotation AB SCIEX
15 Strategies for Metabolite ID pmrm approach Most sensitive technique Comprehensive list of potential metabolites Can screen hundreds of MRM s in a single analysis MS/MS for confirmation collected in automated single injection analysis Multiple Precursor Ion / Neutral Loss Structure specific filtering Ideal for reactive metabolite detection (GSH conjugation) AB SCIEX
16 QTRAP System with LightSight Software Key Benefits for Metabolite ID Advanced workflows High throughput GSH reactive metabolite screening enabled by: Fast polarity switching High LIT sensitivity and speed 20,000 Da/s Fast precursor ion and neutral loss scanning Automated method building LightSight Software Non-targeted metabolite identification Very short dwell times 1-2 ms High Q3 scanning speed and sensitivity AB SCIEX
17 Detection of GSH Conjugates of Reactive Metabolites O OH NH NH H 2 N O O SH O OH OH O O HO O HN H 2 N O NH HS (+) Neutral Loss of 129 (-) Precursors of m/z 272 Applicable to a wide variety of GSH adducts Sensitive and selective Optimum collision energy can vary significantly based on substrate Glutamic acid loss is common Highly selective since it is done in negative ion mode Collision energy is largely independent of substrate structure High sensitivity Requires polarity switch back to positive ion to obtain full product ion spectrum AB SCIEX
18 Comprehensive GSH Conjugate Detection Intensity 2,000 Da/s (+)NL 129 and ( ) Prec of m/z 272 Dual Scans With Fast Polarity Switching (+)NL 129 (-)Prec 272 IDA Enhanced Resolution (+)ER (+)EPI Spectrum from GSH.wiff (sample 13) - troglitazone GSH t60...roglitazone GSH-IDA2, Experiment 4, +EPI (80-800) from min Precursor: Da CH 3 CH H O 2.0e7 3 C O O HO 1.5e7 CH 3 S NH 1.0e7 5.0e GS 440 O ,000 Da/s EPI Scan (+)EPI 0.0e Mass/Charge, Da AB SCIEX
19 Why is the QTRAP System Ideal for this Analysis? Detection: Fast scanning and high sensitivity in precursor ion and neutral loss modes. Fast polarity switching Confirmation Fast scanning (20,000 Da/s) and high sensitivity in Enhanced Product Ion mode for structure elucidation. Rich fragmentation in product ion spectra Usability Automatic method building of complex methods and user friendly data analysis Combined Neutral Loss and Precursor Ion scans provide complementary detection, maximum coverage, and full product ion spectra in the same run AB SCIEX
20 Advanced Transformation List Created in LightSight 2.1 Software AB SCIEX
21 Survey Scan (1) Survey Scan (2) IDA: Powerful & Flexible Survey scan be EMS, EMC, Neutral Loss, Precursor Scan, MRM or EPI (combinations of 2 surveys) Enhanced Resolution Improve Resolution/Accuracy IDA Criteria Level 1 Two levels of criteria Dependent Dependent Scan Scan (s) (s) Dependent Scan (s) Dependent Scan (s) IDA Criteria Level 2 Add to Exclusion List Multiple dependant scans (EPI, Product Ion and MS3) Inclusion/Exclusion List Second Second Dependent Dependent Scan Scan (s) Second Dependent Scan (s) (s) Second Level Dependant Scan (MS 3 ) AB SCIEX
22 Phase II Metabolites Neutral Loss of 80 Neutral Loss of 176 Enhanced Resolution Get Mass of Glucuronide and Sulfate Conjugate Get Isotope Profile Acquire Isotope Ratio Add to Exclusion List Acquire MSMS Spectrum MS 3 MS 3 Get Product Ion Spectrum Fragmentation of Aglicon AB SCIEX
23 Comprehensive Data Processing and Method Building Environment in LightSight Software Potential Metabolites List MS Data Automatic XIC of Selected Metabolite MS/MS Data Now Windows 7 Compatible! AB SCIEX
24 Automatic QTRAP System Method Building Acquisition methods for the QTRAP System combining precursor ion and neutral loss in the same method. Create acquisition methods with 2 survey scans AB SCIEX
25 Theoretical MRM List Generated by LightSight 2.1 Software Q1 Q3 Dwell DP CE CXP Q1 Q3 Dwell DP CE CXP LightSight 2.1 Software automatically lowers declustering potential for glucoronides AB SCIEX
26 QTRAP 5500 (Nefazadone) pmrm AB SCIEX
27 Спасибо AB SCIEX
DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM
DRUG METABLISM Drug discovery & development solutions FR DRUG METABLISM Fast and efficient metabolite identification is critical in today s drug discovery pipeline. The goal is to achieve rapid structural
More informationSimultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2
Technical ote Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2 Alek. Dooley, Carmai Seto, esham Ghobarah, and Elliott B. Jones verview:
More informationAccurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview
More informationImproving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification
Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification Overview LightSight Software for Metabolite Identification is a complete environment
More informationOverview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System
Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS
More informationUnique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS
Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS Using PeakView Software with the XIC Manager to Get the Answers
More informationBiological importance of metabolites. Safety and efficacy aspects
Biological importance of metabolites Safety and efficacy aspects Bernard Walther Technologie Servier Biological importance of metabolites Safety testing of drug metabolites Bioanalytical strategy Structural
More informationMRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics
MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics With Unique QTRAP and TripleTOF 5600 System Technology Targeted peptide quantification is a rapidly growing application
More informationDMPK: Experimentation & Data
DMPK: Experimentation & Data Interpretation Mingshe Zhu, Mike S. Lee, Naidong Weng, and Mark Hayward Prerequisite: Entry-level scientists with hands on experience in LC/MS as well as advanced students
More informationInvestigating Biological Variation of Liver Enzymes in Human Hepatocytes
Investigating Biological Variation of Liver Enzymes in Human Hepatocytes MS/MS ALL with SWATH Acquisition on the TripleTOF Systems Xu Wang 1, Hui Zhang 2, Christie Hunter 1 1 AB SCIEX, USA, 2 Pfizer, USA
More informationMultiQuant Software 2.0 for Targeted Protein / Peptide Quantification
MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can
More informationMetabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants
Metabolomic Profiling of Accurate Mass LC- Data to Identify Unexpected Environmental Pollutants André Schreiber 1, David Cox 1, Nadia Pace 1, Christopher Borton 2 1 AB SCIEX, Concord, ntario, Canada; 2
More informationWhat Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?
What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model? authors M. David Ho 1, Bob Xiong 1, S. Stellar 2, J. Proctor 2, J. Silva 2, H.K. Lim 2, Patrick Bennett 1, and Lily Li 1 Tandem Labs,
More informationIncreasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Scheduled MRM HR Workflow on the TripleTOF Systems Jenny Albanese, Christie Hunter AB SCIEX, USA Targeted quantitative
More informationIn-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
More informationHRMS in Clinical Research: from Targeted Quantification to Metabolomics
A sponsored whitepaper. HRMS in Clinical Research: from Targeted Quantification to Metabolomics By: Bertrand Rochat Ph. D., Research Project Leader, Faculté de Biologie et de Médecine of the Centre Hospitalier
More informationGuidance for Industry Safety Testing of Drug Metabolites
Guidance for Industry Safety Testing of Drug Metabolites U.S. Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research (CDER) February 2008 Pharmacology
More informationamazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS
amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is
More informationThe Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring
The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring Delivering up to 2500 MRM Transitions per LC Run Christie Hunter 1, Brigitte Simons 2 1 AB SCIEX,
More informationis a knowledge based expert decision support tool for predicting the metabolic fate of chemicals in mammals.
is a knowledge based expert decision support tool for predicting the metabolic fate of chemicals in mammals. Reference 08/15 Features and Benefits Summary Efficient Metabolite Structure Elucidation Early
More informationSimultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
More informationProteinPilot Report for ProteinPilot Software
ProteinPilot Report for ProteinPilot Software Detailed Analysis of Protein Identification / Quantitation Results Automatically Sean L Seymour, Christie Hunter SCIEX, USA Pow erful mass spectrometers like
More informationA High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
More informationPesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
More informationA Streamlined Workflow for Untargeted Metabolomics
A Streamlined Workflow for Untargeted Metabolomics Employing XCMS plus, a Simultaneous Data Processing and Metabolite Identification Software Package for Rapid Untargeted Metabolite Screening Baljit K.
More informationAB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs
AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF
More informationDrug Metabolism GUIDE TO INNOVATION
Drug Metabolism GUIDE TO INNOVATION Drug Metabolism Analysis with Confidence Pharmaceutical and biopharmaceutical companies have leveraged advancements in basic science perhaps more than any other industry.
More informationOverview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction
Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)
More informationCliquid ChemoView 3.0 Software Simple automated analysis, from sample to report
PRODUCT BULLETIN Cliquid ChemoView 3.0 Software for Routine Screening and Quantitation Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report KEY FEATURES Secure user login that
More informationMultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples
MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples Fast and Efficient Data Review, with Automatic Flagging of Outlier Results Adrian M. Taylor and Michael
More informationBIOMARKERS AND TOXICITY MECHANISMS 06 Mechanisms Metabolism & Detoxification. Luděk Bláha, PřF MU, RECETOX www.recetox.cz
BIOMARKERS AND TOXICITY MECHANISMS 06 Mechanisms Metabolism & Detoxification Luděk Bláha, PřF MU, RECETOX www.recetox.cz Metabolism and detoxification Chemicals enter body... mostly via food Pass directly
More informationAnalysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS
Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,
More informationTeriflunomide is the active metabolite of Leflunomide, a drug employed since 1994 for the treatment of rheumatoid arthritis (Baselt, 2011).
Page 1 of 10 ANALYTE NAME AND STRUCTURE TERIFLUNOMIDE Teriflunomide TRADE NAME Aubagio CATEGORY Antimetabolite TEST CODE PURPOSE Therapeutic Drug Monitoring GENERAL RELEVANCY BACKGROUND sclerosis. The
More informationAnalyst 1.6.1 Software
MAX cover image size 4.8 inches X 7.8 inches In Body page mode, draw a graphic frame to match this section and then go to the next step. Delete this text from the Front Cover Master page. View>Master Pages,
More informationBruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS
Bruker ToxScreener TM A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS ToxScreener - Get the Complete Picture Forensic laboratories are frequently required
More informationRapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers
RapidFire High-throughput MS technology Enhancing Drug Discovery Turning Mass Specs into Plate Readers 1 Drug Discovery with RapidFire Target Selection High-throughput Target Screening (HTS) Lead Optimization
More informationChapter 8. Summary and Perspectives
Chapter 8 Summary and Perspectives 131 Chapter 8 Summary Overexpression of the multidrug resistance protein MRP1 confer multidrug resistance (MDR) to cancer cells. The contents of this thesis describe
More informationCliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.
Application Note Cliquid Drug Screen & Quant Software A Fast and Sensitive LC/MS/MS Method for the Quantitation and Confirmation of 30 Benzodiazepines and Nonbenzodiazepine Hypnotics in Forensic Urine
More informationLipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going
Lipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going Jeff McDonald Department of Molecular Genetics UT Southwestern Medical Center Dallas,
More informationMS/MS analysis of Polyphenols
Purdue-UAB Botanicals Center for Age-Related Disease MS/MS analysis of Polyphenols Jeevan Prasain Ph.D. Pharmacology & Toxicology UAB Polyphenols H Caffeic acid Phenolic acids and derivatives H EGC (Flavanol)
More informationAPI 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined
API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation
More informationNUVISAN Pharma Services
NUVISAN Pharma Services CESI MS Now available! 1st CRO in Europe! At the highest levels of quality. LABORATORY SERVICES Equipment update STATE OF THE ART AT NUVISAN CESI MS Now available! 1st CRO in Europe!
More informationINTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS
AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,
More informationTutorial 9: SWATH data analysis in Skyline
Tutorial 9: SWATH data analysis in Skyline In this tutorial we will learn how to perform targeted post-acquisition analysis for protein identification and quantitation using a data-independent dataset
More informationMassHunter for Agilent GC/MS & GC/MS/MS
MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data
More informationScreening and quantitative determination of drugs in diluted urine by UPLC-MS-MS
Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS Solfrid Hegstad, PhD Department of Clinical Pharmacology St.Olavs Hospital St.Olavs Hospital Department of Clinical Pharmacology
More informationA Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015
A Navigation through the Tracefinder Software Structure and Workflow Options Frans Schoutsen Pesticide Symposium Prague 27 April 2015 Kings day in The Netherlands 1 Index Introduction Acquisition, Method
More informationAnalyzing Small Molecules by EI and GC-MS. July 2014
Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,
More informationQSAR. The following lecture has drawn many examples from the online lectures by H. Kubinyi
QSAR The following lecture has drawn many examples from the online lectures by H. Kubinyi LMU Institut für Informatik, LFE Bioinformatik, Cheminformatics, Structure independent methods J. Apostolakis 1
More informationEffects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests
Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests AB SCIEX TOF/TOF 5800 System with DynamicExit Algorithm and ProteinPilot Software for Robust Protein
More informationDaniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz
Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische
More informationLecture 4 Sunday 30/9/2012
Inactivation and Detoxification of Xenobiotics and Metabolites in the Liver The liver is one of the most important organs in the body when it comes to detoxifying or getting rid of foreign substances or
More informationMetabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes
Metabolomics Software Tools Xiuxia Du, Paul Benton, Stephen Barnes Outline 2 Introduction Software Tools for LC-MS metabolomics Software Tools for GC-MS metabolomics Software Tools for Statistical Analysis
More informationEthyl Glucuronide. Where is the Drug? Detection Windows. Urine. Blood. Absorption and Distribution. Metabolism. Excretion
Where is the Drug? Ethyl Absorption and Distribution A Biomarker for Ethanol Use Metabolism Excretion Anthony G. Costantino, Ph.D. D-ABFT NMS Labs,Willow Grove, PA John J. Treuting, Ph.D. Treuting & Assoc.
More informationProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry
ProteinScape Proteomics Data Analysis & Management Innovation with Integrity Mass Spectrometry ProteinScape a Virtual Environment for Successful Proteomics To overcome the growing complexity of proteomics
More informationLead optimization services
Lead optimization services The WIL Research Company (WRC) has extensive experience in fast track tailor-made screening strategies to help you with the challenging task of selecting your best candidate
More informationIntegration of DiscoveryQuant Software into Automated In-Vitro ADME Assay Workflows
Integration of DiscoveryQuant Software into Automated In-Vitro ADME Assay Workflows John D. Laycock Ph.D. Principle Scientist, Amgen Pharmacokinetics and Drug Metabolism Applied Biosystems User Meeting
More informationMass Spectrometry Signal Calibration for Protein Quantitation
Cambridge Isotope Laboratories, Inc. www.isotope.com Proteomics Mass Spectrometry Signal Calibration for Protein Quantitation Michael J. MacCoss, PhD Associate Professor of Genome Sciences University of
More informationRapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit
Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit Fast, simple and cost effective analysis Many areas of biochemical research and
More informationAnalytical Methods for Quantification of Drug Metabolites in Biological Samples
Chapter 4 Analytical Methods for Quantification of Drug Metabolites in Biological Samples Robert Roškar and Tina Trdan Lušin Additional information is available at the end of the chapter http://dx.doi.org/10.5772/51676
More information5.111 Principles of Chemical Science
MIT OpenCourseWare http://ocw.mit.edu 5.111 Principles of Chemical Science Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms. 5.111 Principles
More informationDetection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS
Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS D. Loeffler 1, M. Ramil 1, T. Ternes 1, M. Suter 2, R. Schönenberger 2, H.-R. Aerni 2, S, König, A. Besa,
More informationNew drugs of abuse? A case study on Phenazepam & Methoxetamine
New drugs of abuse? A case study on Phenazepam & Methoxetamine Presenter: Nadia Wong Co authors: Dr Yao Yi Ju & Alex Low Xuan Kai Analytical Toxicology Laboratory Clinical & Forensic Toxicology Unit Applied
More informationMass Frontier 7.0 Quick Start Guide
Mass Frontier 7.0 Quick Start Guide The topics in this guide briefly step you through key features of the Mass Frontier application. Editing a Structure Working with Spectral Trees Building a Library Predicting
More informationNursing 113. Pharmacology Principles
Nursing 113 Pharmacology Principles 1. The study of how drugs enter the body, reach the site of action, and are removed from the body is called a. pharmacotherapeutics b. pharmacology c. pharmacodynamics
More informationAnalyst 1.6 Software. Software Reference Guide
Analyst 1.6 Software Software Reference Guide Release Date: August 2011 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment.
More informationExploring Metabolic Outcomes and Toxic Effects. DiscoveryGate SM Version 1.4 SP2 Workshop Guide
Exploring Metabolic Outcomes and Toxic Effects DiscoveryGate SM Version 1.4 SP2 Workshop Guide Exploring Metabolic Outcomes and Toxic Effects DiscoveryGate Version 1.4 SP2 Workshop Guide Elsevier MDL
More informationMarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis
MarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis Overview MarkerView software is a novel program designed for metabolomics applications and biomarker profiling workflows 1. Using
More informationThermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID
Thermo Scientific Compound Discoverer Software A New Generation of integrated solutions for small molecule structure ID Transforming Small Molecule Research Solutions for Small Molecule Structural ID Thermo
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationSimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data
SimGlycan Software*: A New Predictive Carbohydrate Analysis Tool for MS/MS Data Automated Data Interpretation for Glycan Characterization Jenny Albanese 1, Matthias Glueckmann 2 and Christof Lenz 2 1 AB
More information13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
More informationAbsorption of Drugs. Transport of a drug from the GI tract
Absorption of Drugs Absorption is the transfer of a drug from its site of administration to the bloodstream. The rate and efficiency of absorption depend on the route of administration. For IV delivery,
More informationWorkshop IIc. Manual interpretation of MS/MS spectra. Ebbing de Jong. Center for Mass Spectrometry and Proteomics Phone (612)625-2280 (612)625-2279
Workshop IIc Manual interpretation of MS/MS spectra Ebbing de Jong Why MS/MS spectra? The information contained in an MS spectrum (m/z, isotope spacing and therefore z ) is not enough to tell us the amino
More informationThermo Scientific ExactFinder Software
mass spectrometry Thermo Scientific ExactFinder Software Workflow software for routine targeted and general unknown screening Unifies qualitative and quantitative high-resolution accurate mass workflows
More informationTechnical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database
C146-E175A Technical Report Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database Hitoshi Tsuchihashi 1 Abstract: A sample consisting
More informationTOTAL PROTEIN FIBRINOGEN
UNIT: Proteins 16tproteins.wpd Task Determination of Total Protein, Albumin and Globulins Objectives Upon completion of this exercise, the student will be able to: 1. Explain the ratio of albumin and globulin
More informationApplication Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method
Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Introduction During the last decade, the complexity of samples
More informationExtraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
More informationAnalyst 1.6.2 Software. Release Notes
RUO-IDV-03-0236-A Release Date: July 2013 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment. This document is copyright protected
More informationYour partner in immunology
Your partner in immunology Expertise Expertise Reactivity Reactivity Quality Quality Advice Advice Who are we? Specialist of antibody engineering Covalab is a French biotechnology company, specialised
More informationTutorial for Proteomics Data Submission. Katalin F. Medzihradszky Robert J. Chalkley UCSF
Tutorial for Proteomics Data Submission Katalin F. Medzihradszky Robert J. Chalkley UCSF Why Have Guidelines? Large-scale proteomics studies create huge amounts of data. It is impossible/impractical to
More information# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
More informationUsing Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract
Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate
More informationResearch-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE
Research-grade Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, How I learned to ditch the triple quad and love the QE Jacob D. Jaffe Skyline Webinar July 2015 Proteomics and
More informationA Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System
A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System Kent Johnson Fortes lab, Wilsonville Oregon List of drug of abuse candidates for
More informationElectrospray Ion Trap Mass Spectrometry. Introduction
Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic
More informationAgilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS
Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS AGILENT 6000 SERIES LC/MS SOLUTIONS UNRIVALED ACHIEVEMENT AT EVERY LEVEL The Agilent 6000 Series of LC/MS instruments
More informationIndustry Perspective: Advantages of Open Access and Walkup LC/ MS Supporting Protein Drug Discovery and Development
Industry Perspective: Advantages of Open Access and Walkup LC/ MS Supporting Protein Drug Discovery and Development Dawn Stickle, Agilent Technologies Originally presented by Eric Fang, Novartis Overview
More informationUPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research
UPLC-MS/MS Analysis of in Plasma for Clinical Research Dominic Foley and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity improves reproducibility through removal
More informationAbsolute quantification of low abundance proteins by shotgun proteomics
Absolute quantification of low abundance proteins by shotgun proteomics Dr. Stefanie Wienkoop www.proteomefactory.com In cooperation with: Max-Planck-Institut für Molekulare Pflanzenphysiologie Stable
More informationSimultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs
Liquid Chromatography Mass Spectrometry SSI-LCMS-068 Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs LCMS-8050 Summary By utilizing the LCMS-8050 s ultrafast scan
More informationInstrumentation. Sample pretreatment
Analysis of Propofol (2,6-Diisopropylphenol) and its Metabolites in One Injection using the DuoSpray Ion Source AB SCIEX QTRAP 500 LC-MS/MS System and Gerstel, Inc. MultiPurpose Sampler Adrian M. Taylor,
More informationAnalyst 1.6 Software. Getting Started Guide
Analyst 1.6 Software Getting Started Guide Release Date: August 2011 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment. This
More informationUltra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring
PO-CON1359E Ultra Fast UHPLC-LCMSMS Method Development in HPLC 2013 MASS-09 Anja Grüning 1 ; Brigitte Richrath 1 ; Klaus Bollig 2 ; Sven Vedder 1 ; Robert Ludwig 1 1 Shimadzu Europa GmbH, Duisburg, Germany;
More informationA new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications
A new concept for isotope ratio monitoring LC/MS A Wide Range of Applications Andreas Hilkert, Dieter Juchelka, Michael Krummen Thermo Electron (Bremen) GmbH Overview Introduction in Isotope Ratio Monitoring-LC/MS
More informationserum protein and A/ G ratio
serum protein and A/ G ratio Blood plasma contains at least 125 individual proteins. Serum ( as contrasted with plasma) is deficient in those coagulation protein which are consumed during the process of
More informationAppNote 4/2014. Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS.
AppNote 4/2014 Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS. Oscar G. Cabrices, Fred D. Foster Gerstel, Inc., 701 Digital Dr. Suite J,
More informationSample Analysis Design Isotope Dilution
Isotope Dilution Most accurate and precise calibration method available Requires analyte with two stable isotopes Monoisotopic elements cannot be determined via isotope dilution Spike natural sample with
More informationCarl Rosow, M.D., Ph.D. 1 HST-151. Lecture 1 - Principles of Pharmacology: Introduction
Harvard-MIT Division of Health Sciences and Technology HST.151: Principles of Pharmocology Instructor: Dr. Carl Rosow Carl Rosow, M.D., Ph.D. 1 HST-151 Lecture 1 - Principles of Pharmacology: Introduction
More information