97300 NAMUR. Technical data

Size: px
Start display at page:

Download "97300 NAMUR. Technical data"

Transcription

1 9700 NAMUR For single and double acting actuators / or / way function in one valve Easily interchangeable solenoid Compact design Monostable (fail close) & Bistable (fail last position) versions Crossover-free switching, switch-over function guaranteed even with small cross section air supply Manual override with detent Solenoids certified to ATEX, Ex ia and Ex m. For details refer to solenoid information pages & Solenoids approved to IEC Ex, UL, FM etc available on request / and / directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT NAMUR Interface Technical data Medium: Filtered, lubricated or non-lubricated and dry compressed air Operation: Solenoid, indirectly acting Flow direction: Fixed Mounting position: Optional Port size: G/, / NPT Electrical connection: See solenoid table Operating pressure:... 8 bar (below -0 C must be >, bar) Temperature: Valve: - to +0 C Check the air quality for applications below + C Solenoid: see solenoid table Materials: Housing: Aluminium anodized Pilot flange: Plastic (PBT) Flange plate: Aluminium Seals: NBR (Perbunan) Ordering example / solenoid/spring control valve, port size G /, solenoid V d.c., with connector DIN EN form B, protection class IP 6 Type: connector: / / / / /0 Our policy is one of continued research and development. We therefore reserve N/en..8.0

2 9700 NAMUR /, / directional valves, standard design / way or / way function (see conversion instructions page 6) Symbol Type *) port size,, Actuation Operation pressure (bar) *) Flow (l/min) Weight (kg) G / G / Flange Solenoid/Spring , / NPT / NPT Flange Ex ia version, solenoid 09 only G / G / Flange Solenoid/Spring , 9700 / NPT / NPT Flange G / G / Flange Solenoid/Solenoid , / NPT / NPT Flange Ex ia version, solenoid 09 only 9700 G / G / Flange Solenoid/Solenoid ,0 970 / NPT / NPT Flange Dimensions No. *) When ordering please indicate solenoid, voltage and current type (frequency). *) Below -0 C must be >, bar) Solenoid actuators Type Power consumption Ex Protection class Temperature Weight Dimensions Circuit V DC 0 V AC Protection Ambient diagram (W) (VA) Category Fluid ( C) (kg) No. No. 00,7, - IP 6 (with connector) ,0 DIN EN Form B *) 06,6, - IP 6 (with connector) ,090 DIN EN Form A *) 06 - IIG Ex na II T ,00 IID Ex td A IP6 T 9 C with special connector design DIN EN Form A 07 -,0 IIG Ex na II T ,00 IID Ex td A IP6 T 9 C with special connector design DIN EN Form A 06,7 - IIG Ex mb II T ,00 6 *) IID Ex td A IP6 T 9 C Standard wire, m long 06 -, IIG Ex mb II T ,00 6 *) IID Ex td A IP6 T 9 C Standard wire, m long 07,7 - - IP 66 in combination with , Connector Mx (yellow LED) DIN IEC *) Standard voltages V DC, 0 V AC. Other voltages on request. *) Connector is not included in delivery; Required connectors form B or 0707 form A *) Certificate of Conformity PTB No. PTB 0 ATEX 0X *) Connector acc. DIN IEC not included in delivery N/en..8.0 Our policy is one of continued research and development. We therefore reserve /0

3 9700 NAMUR For intrinsically safe circuits, protection class Ex ia IIC T6/T (cat. IIG) and Ex td A IP6 T80 C/T0 C (cat. IID) Type Nom. resistance Required Resistqnce Required voltage Ambient Fluid Weight Dimensions Circuit RN coil switching current Rw 0 coil at terminal temperature temperature max. (kg) diagram (Δ) (ma) (Δ) Rw 0 ( C) ( C) No. No. 09 *6) 7, T T ,8 8 T T +80 Please note - when ordering the intrinsically safe coil please use default voltage code When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in account. On the other hand, the low effective inductivity and capacity can be ignored. *6) Certificate of Conformity PTB 0 ATEX, CSA -Certificate No. LR 090-, FM approved. Required connector acc. to DIN EN form A or ISO 00. Installation acc. to requirements of FM and CSA. Connector is not indicated in delivery. Connector is not included in delivery; required connector: type 0707 form A. Protection class IP6 acc. 609 with connector Accessories Silencer Connectors Flange plate Yoke (G/) *) 0707 form A Single connection plate form A with rectifier 0679 NAMUR-slot use in combination with (Alu) form B *) For indoors use Option selector Function / way, spring return (/ way spare adaptor plate supplied) 0 / way, solenoid return (/ way spare adaptor plate supplied) Ports size G / 0 / NPT Voltage V d.c V a.c. 0.0 Solenoid actuators see table Ex ia version Ex ia version, solenoid 09 only Basic dimensions for valves ➀ ➁,, 6,, 7, Ø, M 6, 0 ø, M 7, 6, 0 0, 0 Manual override Coding stud Solenoid operator Port size G/ or / NPT /0 Our policy is one of continued research and development. We therefore reserve N/en..8.0

4 9700 NAMUR Single connection plate Type: NAMUR slot Type: , M 0 9 G / 9,, 0 M, 6 6 9, 9 ø, ø 9, G /,, ø 9 ø, 7 Yoke Type: x 0 M 0 N/en..8.0 Our policy is one of continued research and development. We therefore reserve /0

5 9700 NAMUR Basic dimensions for solenoid operators ➃ ➄ 9 6 9, , Ø9 Ø9 ➅ ➆ 9 8, 0 Mx 9, 9,, 9, ~ 6 ➇ 9, 7 0 9, Ø9 /0 Our policy is one of continued research and development. We therefore reserve N/en..8.0

6 9700 NAMUR Circuit diagrams ➀ 6 NAMUR hole pattern M Port (A) Coding stud threaded M (0 deep) Port (R) Conversion instructions of / into / way function / way function / way function / / / resp. / way function can be achieved just by swapping enclosed adaptor plates. Make sure Marker and Arrow do match as shown on above drawing. Original mode of supply: / function. 6 Arrow 7 Marker Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products where applicable. N/en Our policy is one of continued research and development. We therefore reserve /0

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

RM/55401/M, Roundline cylinder Magnetic piston, double acting

RM/55401/M, Roundline cylinder Magnetic piston, double acting RM/550/M, Roundline cylinder > > Ø... 00 mm > > Clean line design > > ow friction, long life seals > > Standard magnetic piston for full control system versatility Technical features Medium: Compressed

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

2/2 & 3/2 Solenoid operated valves

2/2 & 3/2 Solenoid operated valves 2/2 & 3/2 Solenoid operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Grey cast iron Plastic resin PVDF Solenoids IP Protection class IP65 (with connector) Buschjost

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP NORTH AMERICAN CYLINDER & ACTUATOR CATALOG > Release 8. Rotary Actuators and Grippers Rotary Actuators, NAMUR interface VDI/VDE 384 & ISO 211 (ATEX certified) Series ARP Model: Rack & Pinion - Rotational

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting K/8000/M, K/8000, ISO cylinder (Stainless steel) > > Ø 3... 00 mm > > High corrosion and acid resistance > > Ideal for applications in the food industry > > Conforms to DIN ISO 555, DIN ISO 63, VDM 56

More information

On-off valves MS-EM/EE, MS series, NPT

On-off valves MS-EM/EE, MS series, NPT On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Control blocks for two-hand start ZSB

Control blocks for two-hand start ZSB Key features Function This pneumatic control block for twohand start ZSB is used where a manually started operation, such as the triggering of compressed air cylinders, would otherwise involve danger for

More information

3/2 Solenoid Cartridge Valve, Size 6

3/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Type 3353 Angle Seat Valve

Type 3353 Angle Seat Valve Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

size 3 15 4200 size 4 19 6600

size 3 15 4200 size 4 19 6600 BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

Solenoid valves VOFC Key features

Solenoid valves VOFC Key features Valve series VOFC Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way valves for process automation, for use within chemical and petrochemical

More information

Solenoid/pneumatic valves, Tiger Classic

Solenoid/pneumatic valves, Tiger Classic Solenoid/pneumatic valves, Tiger Classic Electrically or pneumatically actuated valves With internal or external pilot air Sturdy and reliable Specified types in accordance with ATEX directive for potentially

More information

Tyco PremiAir Pneumatic Actuators

Tyco PremiAir Pneumatic Actuators A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

zamak nitrile rubber self-extinguishing technopolymer aluminum

zamak nitrile rubber self-extinguishing technopolymer aluminum PS COMBOBOX valves - Valves with compact design: valve body with integrated sub-base - High flexibility: > possibility of choosing fitting dimension (--) according to users needs > manifolds from up to

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

-10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890 CL/CM UNIVERSAL Valves G1/8 - CHARACTERISTICS -10 +45 C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 8,5 890 1480 die-cast zamak (G1/8), aluminium () NBR aluminium AA series/u1-u,5

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

ISO/VDMA Actuators. Engineering GREAT Solutions

ISO/VDMA Actuators. Engineering GREAT Solutions ISO/VDMA Actuators Engineering GREAT Solutions 02 ISO/VDMA Actuators Contents 03 Introduction 04 ISO/VDMA Actuators 06 The ISO/VDMA Range 08 Industrial Options 10 Cleanline Options 12 IVAC innovation to

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

FlowPak TM General Application Valve 1/2-4, Class 150

FlowPak TM General Application Valve 1/2-4, Class 150 FlowPak TM General Application Valve 1/2-4, Class 150 SCHERR Application Control of gases, vapours and liquids. The modular concept of valve, multi spring actuator and digital Positioner Type Logix 5si,

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Pressure relief valves Size 6

Pressure relief valves Size 6 Pressure relief valves Size 6 direct controlled Interface to DIN 24 340 and ISO 6264 PN [p max. ] = bar 750400.06.0.06 Description (standard units) Design The pressure relief valves of Type D B C 6 are

More information

9 Control Equipment. Control Button Series 8082

9 Control Equipment. Control Button Series 8082 9 Control Equipment Control Button 01706E00 contact elements enable contact blocks to be combined easily; using an actuator in the 8602 series, regardless of the type of actuator, up to 4 contact elements

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve

Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

Operating Instructions

Operating Instructions Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information