HDCS Copper Solution. Pegasus TM PRECONNECT Copper Cable. Application. Features. Technical Parameters
|
|
- Abigail Rice
- 7 years ago
- Views:
Transcription
1 HDCS Copper Solution Pegasus TM PRECONNECT Copper Cable Application Pegasus TM PRECONNECT copper cable quickly deploys as a permanent link between the distribution area and equipment area in the data center room. Features Quick and easy installation, saving on-site labor cost Guaranteed high reliability based on 100% quality inspection in factory Cat.5e, Cat.6, Cat.6a and Unshielded or shielded options CM, CMR, CMP and LSZH series fire retardant PRECON- NECT copper cable options Each copper permanent link performance far exceeds standard TIA/568C and ISO11801, most notably for short link performance Technical Parameters Complies with relative international standards: TIA 568C / TIA942 ISO11801/ EN Storage temperature: -40 C to 70 C Operation temperature: -20 C to 60 C
2 Ordering Information Ordering Number CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX CPB XXX Products Description Pegasus TM 8Port Cat.6 UTP Box type Preconnect Copper Cable, CM Pegasus TM 8Port Cat.6 UTP Box type Preconnect Copper Cable, LSZH Pegasus TM 6Port Cat.6 UTP Preconnect Copper Cable, CM Pegasus TM 6Port Cat.6 UTP Preconnect Copper Cable, LSZH Pegasus TM 8Port Cat.6 FTP Box type Preconnect Copper Cable, CM Pegasus TM 8Port Cat.6 FTP Box type Preconnect Copper Cable, LSZH Pegasus TM 6Port Cat.6 FTP Preconnect Copper Cable, CM Pegasus TM 6Port Cat.6 FTP Preconnect Copper Cable, LSZH Pegasus TM 8Port Cat.6 UTP Box type Preconnect Copper Cable, CM Pegasus TM 8Port Cat.6 UTP Box type Preconnect Copper Cable, LSZH Pegasus TM 6Port Cat.6 UTP Preconnect Copper Cable, CM Pegasus TM 6Port Cat.6 UTP Preconnect Copper Cable, LSZH Pegasus TM 8Port Cat.6 FTP Box type Preconnect Copper Cable, CM Pegasus TM 8Port Cat.6 FTP Box type Preconnect Copper Cable, LSZH Pegasus TM 6Port Cat.6 FTP Preconnect Copper Cable, CM Pegasus TM 6Port Cat.6 FTP Preconnect Copper Cable, LSZH
3 Pegasus TM Cat.6 Modular Panel Application Pegasus TM Cat.6 modular panel is generally applied to make connections with copper LAN cables at each distribution area in the data center room. Features Each port has a spring dust cover, which provides excellent dust protection Four sets of colored labels attached for convenient cable management Panel with longer back cable management for rear cable tidiness and controlling the cable bending radius. Tool-less keystone jack in panel able to support excellent short link performance Tool-less termination due to an innovative hinged pressing cover, supports labor saving cable termination Technical Parameters Complies with standards: TIA568C / TIA 942 ISO11801 / EN Plug insertion life: 750 cycles min. Plug retention force: 30 lbs min. IDC contactor: Accepts AWG solid wires Temperature range: -40 C to 70 C High Frequency Performance at 20 C Frequency (MHz) Attenuation (db/100m) NEXT RL PSNEXT ELFEXT PSELFEXT Max. Min. Min. Min. Min. Min Ordering Information Ordering Number CP N-E CP31-13C-11 CP N-E CP Description Pegasus TM Cat.6 24P Unshielded modular patch panel (without keystone Jack) Pegasus TM Cat.6 Unshielded Pegasus tool-less keystone jack, black Pegasus TM Cat.6 24P Shielded modular patch panel (without keystone Jack) Pegasus TM Cat.6 Shielded tool-less keystone jack
4 Draco TM Cat.6a Cabling System Application HDCS Draco TM provides Cat.6a products a guaranteed 500MHz bandwidth for high-grade 10Gbps transmission application, and is backwards compatible with all current Ethernet applications, including 10BASE-T, 100BASE-T, 1000BASE-T, etc. Features Shielded and unshielded for customer choice Excellent short link performance based on unique design Backward compatible with Cat.6 and Cat.5e components Meets the requirements of TIA 568C.2 More flexible with Modular structure RoHS-compliant Mechnical Data Mating cycles (RJ45 jack) : 750 times IDC termination cycles: 200 times IDC applicable conductor: 22-26AWG solid Working Temperature: -40ºC to +70ºC High Frequency Performance As per EIA/TIA 568C.2, at 20ºC Frequency (MHz) NEXT RL PSANEXT Min. Min. Min Ordering Information Ordering Number CP31-17E-14 CP CP CP CP CP E CP CP N-E CP X CP X CP X CP X Products Description Draco TM Cat.6a unshielded 90 degree keystone Jack, Ivory Draco TM Cat.6a unshielded standard 180 degree keystone Jack, Ivory Draco TM Cat.6a shielded standard 180 degree keystone Jack, Ivory Draco TM Cat.6a shielded tool-less 180 degree keystone Jack, Ivory Draco TM Cat.6a unshielded modular patch panel, 24-port with keystone Jack Draco TM Cat.6a unshielded modular patch panel, 24-port without keystone Jack Draco TM Cat.6a shielded modular patch panel, 24-port with keystone Jack DracoTM Cat.6a shielded modular patch panel, 24-port without keystone Jack Draco TM Cat.6a UTP patch cord, PVC Jacket Draco TM Cat.6a UTP patch cord, LSZH Jacket Draco TM Cat.6a FTP patch cord, PVC Jacket Draco TM Cat.6a FTP patch cord, LSZH Jacket Note: X stands for length, 1=1meter, 2=2 meters, 3=3 meters
5 Apus TM Cat.6 UTP and FTP Cable Apus TM Cat.6 UTP Data Cable Features HDCS Apus TM indoor and outdoor Cat.6 UTP cables are designed for unshielded cabling systems. HDCS Apus TM Cat.6 cables exceed requirements of TIA 568-C.2 and ISO/IEC nd -Edition with significant margins on all parameters. Cables are available in different jacket materials of various flame-retardant levels. Construction Construction: 4 2 AWG23 Conductor: AWG 23 Solid copper Insulation: HDPE Core: 4 twist pairs Sheath: PVC, LSZH or PE Colour: Grey, Orange, and Black Nominal Diameter: 6.3 mm Application Apus TM Cat.6 Data Cable for structured premise cabling transmits voice, data and video signals. It supports current high-bandwidth applications, and is especially suitable for applications of Fast- Ethernet. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video TR-16 active and passive 155 Mbit /622Mbit /1.2 Gbit ATM 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Electrical Performance at 20ºC DC resistance 9.38ohm/100m Unbalanced resistance 5% Unbalance capacitance 330pF/100m Capacitance 5.6nF/100m Dielectric strength DC 1kv (3s No Fail) Insulation resistance 5000Mohm.Km 1-250MHz (100±15) ohm Impedance MHz (100±25) ohm Delay skew 45ns Mechanical Performance at 20ºC Bending radius During installation (min.) 8 outer diameter Installed (min.) 4 outer diameter Temperature range During installation 0ºC to +50ºC Installed -20ºC to +60ºC
6 High-Frequency Performance at 20ºC Frequency (MHz) Attenuation (db/100m) NEXT RL PSNEXT ELFEXT PSELFEXT ACR Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max Characteristic Graph Ordering Information Order Number CP * CP CP * CP * CP Description Apus TM Cat.6 indoor UTP cable, CM, 305m (Box) Apus TM Cat.6 indoor UTP cable, LSZH, 305m (Reel in box) Apus TM Cat.6 indoor UTP cable, CMR, 305m (Box) Apus TM Cat.6 outdoor UTP cable, PE, 305m (Reel) Apus TM Cat.6 outdoor UTP cable, PE, 305m (Reel)
7 Apus TM Cat.6 UTP and FTP Cable Apus TM Cat.6 FTP Data Cable Features and Benefits HDCS Apus TM indoor and outdoor Cat.6 FTP cables are designed for shielded cabling systems. HDCS Apus TM Cat.6 cables exceed TIA 568-C.2 and ISO/IEC nd requirements for Cat.6 performance by significant margins on all parameters. Cables are available in different jacket materials of various flame-retardant levels. Construction Construction: 4 2 AWG23 Conductor: AWG 23 solid copper Insulation: HDPE Core: 4 twist pairs Foil: PET tape Screen: AL/PET tape Drain wire: AWG23 tinned copper (Lay longitudinally under the AL/PET tape) Sheath: PVC, LSZH or PE Colour: Grey, Orange, and Black Nominal diameter: 7.4 mm Application Apus TM Cat.6 Data Cable for structured premise cabling transmits voice, data and video signals. It supports current high-bandwidth applications, and is especially suitable to shielded Class E Solutions. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video TR-16 active and passive 155 Mbps /622Mbit /1.2Gbps ATM 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Electrical Performance at 20ºC DC resistance 7.5 ohm/100m Unbalanced resistance 5% Unbalance capacitance 330pF/100m Capacitance 5.6nF/100m Dielectric strength DC 1kv, 3s No Fail Insulation resistance 5000MΩ.km Impedance (100±15) ohm Delay skew 45 Mechanical Performance at 20ºC Bending radius During installation (min.) 8 outer diameter Installed (min.) Temperature range During installation Installed 4 outer diameter 0ºC to +50ºC -20ºC to +60ºC
8 High-Frequency Performance at 20ºC Frequency (MHz) Attenuation (db/100m) NEXT RL PSNEXT ELFEXT PSELFEXT ACR Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min. Max Ordering Information Order Number CP CP CP CP CP Description Apus TM Cat.6 outdoor FTP cable, PE, 305m Apus TM Cat.6 indoor FTP cable, CM, 305m Apus TM Cat.6 indoor FTP cable, LSZH, 305m Apus TM Cat.6 indoor FTP cable, CMR, 305m Apus TM Cat.6 indoor FTP cable, CMP, 305m
9 Draco TM Cat.6a UTP and FTP Cable Draco TM Cat.6a (10G) UTP Data Cable Features HDCS Draco TM indoor and outdoor Cat.6a 10G UTP cables are designed for unshielded cabling systems. HDCS Draco TM 10G UTP cables exceed requirements of TIA/EIA-568-C.2 and ISO/IEC nd -Edition with significant margins on all parameters specified specifically for 10G applications, with a testing frequency up to 500MHz. Cables are available with different jacket materials (CM, CMR, LSZH, CMP, etc.) of various flameretardant levels. Construction Construction: 4 2 AWG23 Conductor: AWG 23 solid copper Insulation: HDPE Core: 4 twist pairs Sheath: PVC, LSZH or PE CMR as per UL 1666 LSZH as per IEC , , , CMP as per UL 910 Color: Grey (CM, CMR, CMP), Orange (LSZH) Nominal Diameter: 8.6 mm Application: HDCS Draco TM Cat.6a Data Cable for structured premise cabling transmits voice, data and video signals. It supports current and future high-bandwidth applications, and is especially suitable for application of Class E. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video TR-16 active and passive 155 Mbps /622Mbit /1.2 Gbps ATM 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Electrical Performance at 20ºC DC resistance 7.32ohm/100m Unbalanced resistance 5% Unbalance capacitance 330pF/100m Capacitance 5.6nF/100m Dielectric strength DC 1kv (3s No Fail) Insulation resistance 5000Mohm.Km 1-250MHz (100±15) ohm Impedance MHz (100±25) ohm Delay skew 45ns Mechanical Performance at 20ºC Bending radius During installation (min.) 8 outer diameter Installed (min.) Temperature range During installation Installed 4 outer diameter 0ºC to +50ºC -20ºC to +60ºC
10 Transmission Performance (20ºC) Frequency (MHz) Attn (db/100m) NEXT RL PSNEXT ELFEXT PSELFEXT ACR Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min Ordering Information Ordering Number CP CP CP CP Products Description Draco TM Cat.6a indoor UTP cable, CM, 305m Draco TM Cat.6a indoor UTP cable, LSZH, 305m Draco TM Cat.6a indoor UTP cable, CMR, 305m Draco TM Cat.6a indoor UTP cable, CMP, 305m
11 Draco TM Cat.6a UTP and FTP Cable Draco TM Cat.6a (10G) FTP Data Cable Features and Benefits HDCS Draco TM Cat.6a (10G) FTP cables are designed for unshielded cabling systems. HDCS Draco TM 10G FTP cables exceed requirements of TIA/EIA-568-C.2 and ISO/IEC nd -Edition with significant margins on all parameters specified specifically for 10G applications, with a testing frequency up to 500MHz. Cables are available with different jacket materials (CM, CMR, LSZH, CMP, etc.) of various flame-retardant levels. Construction Construction: 4 2 AWG23 Conductor: AWG 23 solid copper Insulation: HDPE Core: 4 twist pairs Wrap tape: PET Grounding wire: 23AWG tinned copper conductor Shielding: AL/PET tape Sheath: PVC, LSZH or PE CMR as per UL 1666 LSZH as per IEC , , , CMP as per UL 910 Color: Grey (CM, CMR, CMP), Orange (LSZH) Nominal Diameter: 7.6 mm Application HDCS Draco TM Cat.6a Data Cable for structured premise cabling transmits voice, data and videosignals. It supports current and future high-bandwidth applications, and is especially suitable for application of Class E. VoIP ISDN Token ring 100 Mbps TP-PMD Analog and digital video TR-16 active and passive 155 Mbps /622Mbit /1.2 Gbps ATM 10baseT/100baseTX Fast /1000baseTX Gigabit Ethernet Electrical Performance at 20ºC DC resistance 7.32ohm/100m Unbalanced resistance 5% Unbalance capacitance 330pF/100m Capacitance 5.6nF/100m Dielectric strength DC 1kv (3s No Fail) Insulation resistance 5000Mohm.Km 1-250MHz (100±15) ohm Impedance MHz (100±25) ohm Delay skew 45ns Mechanical Performance at 20ºC Bending radius During installation (min.) 8 outer diameter Installed (min.) Temperature range During installation Installed 4 outer diameter 0ºC to +50ºC -20ºC to +60ºC
12 Transmission Performance (20ºC) Frequency (MHz) Attn (db/100m) NEXT RL PSNEXT ELFEXT PSELFEXT ACR Propagation delay (ns/100m) Max. Min. Min. Min. Min. Min. Min Ordering Information Ordering Number CP CP CP CP Products Description Draco TM Cat.6a indoor FTP cable, CM, 305m Draco TM Cat.6a indoor FTP cable, LSZH, 305m Draco TM Cat.6a indoor FTP cable, CMR, 305m Draco TM Cat.6a indoor FTP cable, CMP, 305m
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationTECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION 4 PAIR UTP CABLE (ENHANCED CATEGORY 5) PVC (CM Grade) Page 1 of 6 1. SCOPE This specification is based on the specifications of UL 444, ANSI/TIA/EIA-568-B.2, UL 1685 and covers
More informationThe Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
More informationCopper Cables CONNECTIVITY & CABLING SYSTEM
Copper Cables CONNECTIVITY & CABLING SYSTEM Category 5E M0502057-91 EN CPR 6707 U/UTP tested up to 200 MHz U/UTP CAT5E, unshielded 4-pair cable (100 Ohm), with PVC or LSZH (Low Smoke Zero Halogen) outer
More informationLS Data Communication Product
www.lscable.com 2007 LS Cable, Ltd. All right reserved. This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation.
More informationR&Mfreenet Advanced Cat 6 A Unshielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationAccelerating Light. Copper Cabling Solutions. Category 6A
Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity
More informationSession 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair
Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;
More informationAlways with Our Customers
LS Simple TM Structured Cabling System 2010 LS Cable, Ltd. All right reserved Ver 01. Jan.1001 Always with Our Customers www.lssimple.com 12F~17F, LS Tower, 10266, Hogyedong, Dongangu, Anyangsi, Gyeonggido,
More informationHIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
More informationIT Cabling Solutions
IT Cabling Solutions Signamax & Hitachi Cable America System Performance Signamax & Hitachi Cable America (Hitachi) system quality assurance testing is based on the worst-case model - four-connector 100-meter
More informationE Series. E Series. Category 6 and 5e. Features
E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.
More informationEvolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationGulf Cable & Electrical Ind. Co.
CONTENTS INTRODUCTION PRODUCT RANGE I PRODUCT DATA TABLES Irrigation 1 Coaxial s for T.V/ Satellite Antenna etc 2 Data Transmission s - 4 pair 24 AWG 3 TELEPHONE CABLES Telephone cables CCP-LAP & CCP-LAP-SS
More informationCopper Systems Contents
Copper Systems Copper Systems Contents Augmented Category 6 Systems 10GPlus Page 1.3 Category 7 Systems U-MediaPlus Page 1.11 Category 6 Systems Cat6Plus Page 1.13 Category 5e Systems GigaPlus Page 1.29
More informationMixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd
More informationHARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
More informationCategory 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
More information01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
More informationCAVEL VS80205 MADE IN ITALY 1000 V
0,05 9,00 x 7,20 (Pet) (LSZH) Attached CE01 CE02 Sheath Colour black black red Non-migrating Polyester tape longitudinally overlapped (Pet) 25 x 23 µm Outer sheath of Thermoplastic material - black - halogen-free,
More informationSealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
More informationC 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
More informationSound, Alarm & Security Cable 7
Electronics Sound, Alarm & Security Cable 7 Index Page The sound and security industry in the United States has grown from a simple and unsophisticated business, begun some 45 years ago, to one which has
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More information108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
More informationATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification Abstract Presented in this document are the standards to implement Electrical & Optical Ethernet components, cabling, connections,
More informationCategory 6 UTP - Cabling System
AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP
More informationSMARTen 24 UTP Patch Panels
Features High density, 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Special cap design for minimizing Alien Cross-Talk Conform to ANSI/TIA/EIA-568-B.2-10,
More informationTotal Solutions Verification
Total Solutions Verification 3rd Party Electrical Performance Testing Author: Tom Boucino Applications Engineer Uniprise Solutions CommScope has always designed cables with connectivity in mind. Our engineers
More informationRequirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)
Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Introduction The purpose of this document is to: 1) provide background information beneficial to specifiers
More informationSYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions. www.commscope.
SYSTIMAX Solutions GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions www.commscope.com The SYSTIMAX GigaSPEED X10D Shielded Solution provides unprecedented performance
More informationInnovative Connectivity Solution for Maximum Performance and Security
Innovative Connectivity Solution for Maximum Performance and Security Financial Institutions Supports high performance backbone which enables transfer of real-time financial information through voice,
More information1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
More informationGigabit Ethernet over fiber optic cable.
1000BaseT 1000BaseFX 100BaseTX 100BaseFX 100BaseLX 100BaseSX 100BaseT2 100BaseT4 100BaseTX 10Base2 10Base5 10BaseT ACR 1000 Mbps, 1 Billion bits per second data transmission over copper cabling. All four
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.
WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of
More informationThe Quality Connection. Solutions@KERPEN IT Cabling Systems
The Quality Connection Solutions@KERPEN IT Cabling Systems Contents At a glance Introduction Page MegaLineNet and GigaLineNet Applications and market segments Page Copper Cables and Systems: MegaLineNet
More informationHARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
More informationNetworking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka What is a network? A computer network is two or more computers connected together using a telecommunication system for the purpose
More information12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)
1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled
More informationSMARTen 24 STP Patch Panels
Features Support 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Conform to ANSI/TIA/EIA-568-B.2-10, ISO/IEC 11801 2.1 edition and CENELEC
More informationCategory-6 / Class-E Cabling
Category-6 / Class-E Cabling IEEE 802 Tutorial July 7, 1998 San Diego, CA by: Luc Adriaenssens SYSTIMAX Systems Applications Director Bell Labs of Lucent Technologies How were the ISO Cat-6 Targets set?
More informationPresenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
More informationOutdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationFlexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
More informationCat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.
Cat 5, 6 or 7? A University Standard for Structured Wiring. Background isolutions recently formed Incorporates all IT service providers within the University. Focus on all ICT needs of the user and the
More informationHARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
More informationHow to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category
More informationWHITE PAPER December, 2001
Is Superior Essex Outside Plant Copper Cable Rated Category 3? The applicability of the Category 3 specification to outside plant cables is sometimes misunderstood. This white paper examines that issue,
More informationRTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation
RTEX Cable 2015/10/1 Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation Cable and Connector Page 2 2015/10/1 Rev. 5 Motor Business Unit, AIS Company The Kind of Ethernet
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationUniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
More informationPlanning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER
Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission
More informationPANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security
PANDUIT TX6 GIG SHIELDED COPPER CABLING SYSTEM Innovative Connectivity Solution for Maximum Performance and Security Gigabit Ethernet over Copper With ever increasing bandwidth requirements, advancements
More informationTENDER: Tf{/0006120151 A
/ %] *-@*telecom W* namibia TENDER: Tf{/0006120151 A The Supply and Delivery of Various optic fiber cables for the period of thre years For Telecom Namibia Tenderer name: { Total offer: N$. Page 1 of 19
More informationNetwork Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
More informationCabling for 10GBASE-T and Beyond - A Tangled Web
Augmented Category 6 Category 6 A CLC TR 50173-99-1 TIA/EIA-TSB-155 TIA/EIA-568-B.2-10 ISO/IEC 11801 A1.1 Class E A Class F A ISO/IEC 11801 A1.2 Category 7 A ISO/IEC TR 24750 ISO/IEC 11801 Cabling for
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationData Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation
Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify
More informationSHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS
STRUCTURED CABLING SHEET 1 COMMUNICATION NETWORKS COMPUTER AND TELEPHONE SYSTEMS INTRODUCTION In recent years, communications have taken on a crucial role in development for businesses. Communications
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationEthernet Cat 5e & Cat 6 Patch Panels
Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More informationPatch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies
Patch Cords / Cable / Cable Assemblies Premise Connectivity Systems Patch Cords/Cable/ Cable Assemblies w w w. s i g n a m a x. c o m Category 6A 10G Patch Cords C1 Patch Panels and Cross- Category 6 Patch
More informationTechnical Information and System Application Guide
Technical Information and System Application Guide Table of Contents A STRUCTURED CABLING DESIGN CONCEPT B BACKBONE CABLING C HORIZONTAL DISTRIBUTION D CABLING SPECIFICATIONS E APPLICATION DESIGNS F TECHNICAL
More informationCommercial Coaxial Cable
Commercial Coaxial Cable For the Best in COMMERCIAL TV Reception Solutions! Do you require a Digital TV reception system for your next project? Matchmaster can supply For The Best Design and supply of
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationCopper Cabling Infrastructure Offering
Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationDisclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.
Commercial Building Telecommunications Cabling Standard Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.
More informationB. PART 1 - GENERAL of SECTION 271300 BACKBONE COMMUNICATIONS CABLING shall also apply to this section.
SECTION 271500 - HORIZONTAL UTP CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationHARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
More informationMICRO SFP+ CONNECTOR & CABLE ASSEMBLY
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.
More informationSimpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug
Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.
More informationAWG: Cat5e: Cat6: Cat6A:
Some of the terms used in the cable business can be vexing to even the most seasoned folks in the industry. If any of this terminology has ever made you scratch your head, you are certainly not alone.
More informationGigabit Ethernet on Copper Cabling Infrastructures
Gigabit Ethernet on Copper Cabling Infrastructures Overview of Gigabit Ethernet (1000Base-T) Ethernet was developed by the Xerox Corporation in the early 1970 s and has emerged as the dominant networking
More informationData Cables. European Edition
Data Cables European Edition Belden Data Cables Reliable Performance through Innovation Table of Contents Reliable Performance through Innovation Belden Quality Cable Finder Unshielded cables UTP Category
More informationC6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A
C6 A modul and C6 A modul K The new connection system for all applications of course with Cat.6 A Intelligent solution for structured cabling systems There is an enormous need for high data transfer rates
More informationWhite Paper. Power over Ethernet Plus Update and Cabling Considerations
White Paper Power over Ethernet Plus Update and Cabling Considerations Power over Ethernet Plus Update and Cabling Considerations TABLE OF CONTENTS 1. Introduction...3 2. Application Objectives...5 3.
More informationcoaxial cable coaxial Cable CERTIFIED 100% certified coaxial cable A cable that is marked Televés, no doubt is a certified cable
COAXIAL CABLE coaxial Cable 100% certified coaxial cable coaxial cable CERTIFIED The step ahead undertaken by Televés to improve its service and technical excellence, is now reflected in this new challenge.
More informationPolymer Coated Fiber Cable (PCF)
Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability
More informationCables. Indoor, Outdoor, HDMI, CAT, connectors. Cables, connectors and tools
Indoor, Outdoor, HDMI, CAT, connectors, connectors and tools Indoor Outdoor Fly leads HDMI CAT F -/IEC connectors F -/IEC adaptors F - terminator Connection cables Power cables and electricity articles
More informationNetwork Engineers Everywhere:
Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationCat. 6 A EL Incredibly fast Get more
Cat. 6 A EL Incredibly fast Get more Productive Intuitive installation Reliable Dependable connection Flexible Wide range of applications Productive. Intuitive installation. Just a few flicks of the wrist
More informationProduct Bulletin. One Enterprise. One Infrastructure. One Partner. Shielded Cabling Systems
Product Bulletin PB373 Shielded Cabling Systems Belden s complete portfolio of shielded Category 6A, Category 6 and Category 5e Systems offer superior performance, outstanding reliability and effective
More informationThis paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:
UTP Technology In the late 1970s, unshielded twisted pair (UTP) cabling originated in the computer industry as a means of transmitting digital data over computer networks. This cable was designed to be
More informationWhat are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France
Title: Source: Author: Contact: What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France Jack Douglass Jack Douglass Paradyne Networks, Inc. Voice: 949-233-3558 Email:
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationCOUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq
More informationWhite Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems
White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems Asef Baddar, RCDD Principal Engineer / Applications Engineering Supervisor Leviton Network Solutions C/7 - #1928 Table of Contents Background
More informationKeystone Network Isolator with ESD- and Lightning Protection
Keystone Network Isolator with ESD- and Lightning Protection Introduction The Network Isolator is utilized in copper-based network connections (Ethernet), in order to protect a device linked with the network
More informationNew Technology Developments and How They Impact Your Structured Wiring Choices
New Technology Developments and How They Impact Your Structured Wiring Choices Author: Rob Wessels Vice President of Engineering Structured wiring has come a long way since the days when Category 3 and
More information