Medium Voltage Distribution Catalogue Ringmaster. Ring Main Unit
|
|
|
- Noel Peregrine Adams
- 10 years ago
- Views:
Transcription
1 Medium Voltage Distribution Catalogue 2012 Ringmaster Ring Main Unit
2
3 Ringmaster range General contents Presentation 3 Ring main units 15 Circuit breaker, metering and switches 35 Remote control 83 Installation drawings 87 Schematic diagrams 99 Accessories 141 Schneider Electric, an overview and order form 149 AMTED399086EN.indd 1
4 2 AMTED399086EN.indd
5 Presentation Contents Applications 4 Switchgear description 5 VIP protection relays 7 Sepam series 10 8 Network remote control 12 Ringmaster selection guide 14 AMTED399086EN.indd 3
6 Presentation Applications Ringmaster is the ideal choice for all your MV applications. From simple transformer protection, or sectionalising with remote control, to multi-panel metered consumer switchboards, the Ringmaster range from Schneider Electric offers a solution. Quality engineering for extreme climates enables Ringmaster to provide fl exibility for any location. Covering a wide range of options with an indoor and outdoor IP54 design and ratings up to 13.8 kv, 630 A and 21 ka, Ringmaster has proved successful in markets around the world. Product advantages Simple, clear operation combined with compact size, high functionality and reliability extends the applications of the Ringmaster range. Safety to personnel Fully certifi ed internal arc design. Indoor/outdoor design No need for expensive switchrooms. Self powered protection Not reliant on costly battery chargers. Compact Reduced dimensions, gives reduced civil costs. Virtually maintenance free Low lifetime costs. Modular design Quick, simple & easy to install. Proven design Assured consistent quality. ISO 9001 quality certifi cation. PE40438 Environmental Manufactured to ISO environmental standards. 4 AMTED399086EN.indd
7 Presentation Switchgear description A variety of different panel types are available for each unit within the range, together with a number of optional accessories enabling Ringmaster to satisfy the most complex system specifi cation. A multitude of configurations PE57061 Free standing, non-extensible, cable connected ring main unit. Transformer mounted, non-extensible ring main unit, incorporated in a packaged substation. Free standing, extensible cable connected ring main unit Transformer mounted, extensible ring main unit, incorporated in a packaged substation. PE57063 PE57066 PE57062 PE57065 PE57064 Free standing, non-extensible circuit breaker. Cable connected extensible switchboard. AMTED399086EN.indd 5
8 PresentationSwitchgear description PE57067 General characteristics b Gas pressure indicator as standard b Anti-refl ex operating handle with facilities for electrical operation b Interlocked MV cable test access (no need to remove cable terminations or use loose earthing devices) b Integral self-powered protection with TFL, adjustable curve & relay options b IP54 enclosure b Simple to follow mimic providing user-friendly operation b Earth screened cast-resin gas module b Range of dry type metering units b Mechanical tripped on-fault indication b Resin encapsulated busbars in air bus chamber for extensible version b Direct coupling to transformers or cable connection. Standard and quality assurance Manufactured to BS EN ISO Ringmaster meets the following standards and has obtained approval from the UK Electricity Association: IEC , IEC 60265, IEC , BS EN and ENA TS Environmental Management System BSEN ISO OHSAS Management of Health and Safety. 6 AMTED399086EN.indd
9 Presentation VIP protection relays Self-powered reliability PE57160 VIP the leading protection relay providing a wide range of selectivity and quality of supply The VIP 300 is a three phase overcurrent and earth fault protection device, providing protection for networks and equipment. Being an integral part of the highly successful Ringmaster range, its main function is to detect phase and earth faults within the network and to trip the circuit breaker. VIP 300 b Pick-up current ranges: RN2c, RE2c, CN2, CE2 Overcurrent: A. Earth fault: A. CE6 and RN6c Overcurrent: A. Earth fault: 8 A to 640 A. Hardened electronics Certifi ed EMC performance to IEC and EN 50061, EN b Separate overcurrent and earth fault trip indication. b Flashing LED s indicate when the relay is operating under fault conditions. Flexibility The relay provides for a wide range of protection settings for most applications. The IDMT characteristics employed for both the overcurrent and earth fault elements can be easily adjusted to provide discrimination with upstream MV and downstream LV protective devices. Fast power-up of the VIP 300 also provides immediate protection and can detect faults instructing the CB to trip in less than 40 ms. Reliability The relay has a self monitoring device and diagnostic routine that constantly checks the operation of the relay automatically. PE57159 Self-powered reliability The VIP 300 protection relay is a self powered microprocessor based device which requires no external DC power source or batteries, making it the ideal solution for location in remote areas where auxiliary supplies are not readily available. Ease of use VIP 300 has improved operation and control with the relay settings being clearly displayed on the front panel. Manual reset fl ags show separate tripped on fault for either phase or earth fault conditions. PE56826 VIP 35 provides protection against phase-to-phase faults and earth faults. Testing The VAP 6 hand held test unit, is available to provide a simple check of the integrity of the relay and can also be used to perform trip tests on the circuit breaker. The circuit breaker trip inhibit facility allows the relay to be tested without tripping the circuit breaker. Secondary injection can be carried out using conventional test equipment. The VIP 30 and VIP 35 are self-powered devices, requiring no external DC power source or batteries. They are designed for use in distribution networks providing protection for transformers. VAP 6 AMTED399086EN.indd 7
10 Presentation Sepam series 10 PB Sepam series 10 Sepam series 10 is a high-quality protection relay that represents the most costeffective solution available for essential protection functions. Highly ergonomic, it is easy to install and set up. Sepam series 10 specifics Sepam series 10 monitors phase and/or earth-fault currents. Three models meet a wide range of different needs : b N: Sepam series 10 N protects against earth faults b B: Sepam series 10 B protects against overloads, phase-to-phase faults and earth faults b A: Sepam series 10 A provides the same functions as Sepam series 10 B, with also a communication port, more inputs and outputs, and additional protection and monitoring functions. Simplicity b Easy operation - screen, keys, pictograms, etc., good ergonomics b Fast set-up - installation, wiring, parameter setting directly on the relay without a PC. Reliability b Guaranteed protection of life and property - high-quality product, compliance with standards, continuous self-test b Safety of operating personnel - all accessible parts are made of insulating materials, light and compact product with no sharp edges b Environmentally friendly - compliance with the European RoHS directive, low energy consumption, manufacture in factory certifi ed ISO and recyclable to more than 85%. Productivity b Attractive, cost-effective product - easy to understand, no unnecessary complications, suited to user needs b Improved availability of electricity - precise tripping set points and times, logic discrimination, detailed information made spontaneously available to operator following tripping. b Reduced maintenance costs - continuous self-tests to extend periods between maintenance. Functions ANSI code Sepam series 10 N B A Protections Earth-fault protection Standard 50N/51N v v v Sensitive v v High sensitivity v v v Phase-overcurrent protection 50/51 b b Thermal overload protection 49RMS b b Phase-overcurrent and earth fault protection b b cold load pick-up Logic discrimination Blocking send 68 b b b Blocking reception b External tripping b Measurements Earth-fault current b b b Phase currents b b Peak demand currents b b Control and supervision Circuit breaker tripping and lockout 86 b b b Tripping indication b b b Trip-circuit supervision b Remote circuit-breaker control b Record of last fault b b Record of last fi ve events b Communication Modbus b IEC b Inputs/Outputs (number) Earth-fault current inputs Phase-current inputs - 2 or 3 3 Logic relay outputs Logic inputs Communication port b Function available. v Function availability depends on the Sepam model. 8 AMTED399086EN.indd
11 Presentation Sepam series 10 User-machine interface and dimensions User-machine interface 1 Back-lit display 2 Status LEDs 3 Fault LEDs 4 Button for Sepam reset and maximeter reset 5 Battery housing (Sepam series 10 A) 6 Protection cover for settings 7 Identifi cation zone 8 Lead-seal accessory 9 Button for setting selection and confi rmation 10 Buttons for selection in a menu 11 Button to cancel entry 12 Buttons for setting adjustments 13 Button for menu selection and LED test 14 Menu pictograms 15 Cursor for menu selection DE53450_SE Dimensions DE53451_SE Characteristics Applicable to Value Dimensions series x 140 x 90 mm / 7.09" x 5.51" x 3.54" Weight depending on number of current inputs series 10 N 1 series 10 B 3 series 10 A kg/2.53 pounds 1.26 kg/2.78 pounds 1.46 kg/3.22 pounds Type of battery series 10 A 1/2 AA Li 3.6 V AMTED399086EN.indd 9
12 Presentation Sepam series 10 Protection functions Earth-fault protection (ANSI 50N-51N) DE53229 t Earth-fault protection detects overcurrents caused by phase-to-earth faults. It uses measurements of the fundamental component of the earth-fault current. 2 independent set points (Io> and Io>>) b The low set point (Io>) offers defi nite time (DT) or IDMT settings with various types of standardized curves (IEC, IEEE, RI) and it is possible to enable an IDMT timer hold. b The high set point (Io>>) offers only the defi nite time (DT) setting. The minimum setting results in instantaneous operation (ANSI 50). Depending on the required level of sensitivity, there are three types of Sepam relays. Sensitivity Sensor Setting range Standard 3 phase CTs or 1 earth-fault protection CT, Ino with rated primary current Ino Sensitive (1) 3 phase CTs or 1 earth-fault protection CT, with rated primary current Ino Ino Io> Io>> Io High Special core balance CSH or GO, with ratio of 470/1 sensitivity (1) Setting not available with Sepam series 10N A primary, i.e Ino Phase-overcurrent protection (ANSI 50-51) Phase-overcurrent protection detects overcurrents caused by phase-to-phase faults. It uses the measurements of the fundamental component of currents drawn from two or three phase CTs, with a secondary rating of 1 A or 5 A. 2 independent set points (I> and I>>) b The low set point (I>) offers defi nite time (DT) or IDMT settings with various types of standardized curves (IEC, IEEE, RI) and it is possible to enable an IDMT timer hold. b The high set point (I>>) offers only the defi nite time (DT) setting. The minimum setting results in instantaneous operation (ANSI 50). DE53228 t Thermal image overload protection (ANSI 49 RMS) This protection function is used to protect cables and HV/LV transformers against overloads, based on measurement of the current drawn. The function is based on a thermal model which calculates the temperature rise from current measurements. The current measured is an RMS 3-phase current which takes into account harmonics up to number 13. Two protection settings b The continuous maximum permissible current setting which corresponds to the maximum thermal withstand of the protected devices (the continuous permissible current corresponds to a temperature rise of 100%). b The setting for the equipment heating and cooling time constant. Ith I> I>> I 10 AMTED399086EN.indd
13 Presentation Sepam series 10 Protection functions DE53195 DE53194 Sec I/I> or Io/Io> IEC curves SI, VI, LTI, EI and RI curve Sec LTI/B RI SIT/A VIT/B EIT/C MI VI I/I> or Io/Io> IEEE curves MI, VI, EI EI Protection function 50/51, 50N/51N Tripping curve b DT: Defi nite time b SIT/A: IEC standard inverse b VIT/B: IEC very inverse b LTI/B: IEC long-time inverse b EIT/C: IEC extremely inverse b MI/D: IEEE moderately inverse b VI/E: IEEE very inverse b EI/F: IEEE extremely inverse b RI I>, I>> set points DT curve In (minimum: 1 A) IDMT curves In (minimum: 1 A) Accuracy ±5% or ±0.02 In Drop out/pick up ratio 95% Transient overshoot < 10% Io>, Io>> set points DT curve Standard version Setting range: Ino (minimum: 1 A) Sensitive version High sensitivity version Rating A Rating A Setting range: Ino (minimum: 0.1 A) Setting range: Ino (Ino = 470 A) Setting range: Ino (Ino = 470 A) IDMT curves Standard version Setting range: Ino (minimum: 1 A) Sensitive version Setting range: Ino (minimum: 0.1 A) High sensitivity version Rating A Rating A Setting range: Ino (Ino = 470 A) Setting range: Ino (Ino = 470 A) ±5% or ±0.02 Ino Accuracy Drop out/pick up ratio 95% Transient overshoot < 10% Time delay DT curve s IEC, RI curves TMS: (step: 0.01) IEEE curve TD: (step: 0.1) Accuracy DT curve: ±2% or ±20 ms IDMT curves: ±5% or ±20 ms Timer hold Accuracy Characteristic times Operation time Overshoot time Reset time Protection function 49RMS Selection: ON/OFF. Common setting for I> and Io> set points ±2% or ±20 ms < 40 ms at 2 x set point (typically 25 ms) < 40 ms at 2 x set point < 50 ms at 2 x set point Set points Alarm set point Setting range % of permissible thermal capacity Trip set point Setting range In (value of permissible current) Accuracy ±5% or ±0.02 In Drop out/pick up ratio 95% Time delay Time constant Setting range min in 1 min steps Tripping-time accuracy ±2% or ±2 s AMTED399086EN.indd 11
14 Presentation Network remote control T200E telecontrol Ringmaster and T200E Control your Ringmaster from a remote position The Schneider Electric Easergy T200E telecontrol cabinet, which links the Ringmaster to a control centre s automation system, allows you to manage a secondary distribution network from a remote point. Network faults can be identifi ed and isolated and the network reconfi gured in seconds without manual intervention, which substantially improves the quality of supply. The small and compact Easergy T200E can be easily mounted directly onto the Ringmaster, saving installation costs and valuable fl oor space. Telecontrol equipment can be added any time after installation. This makes Ringmaster RMU s even more cost-effective to install, since a control system can be bought separately if needed at a later date. Other RTUs can also be integrated if required. PE57069 PE57071 Internal view of Easergy T200E Ringmaster C with Easergy T200E 12 AMTED399086EN.indd
15 Presentation Network remote control Easergy L500 Continuity of service guaranteed by an overall telecontrol offer Schneider Electric offers you a complete solution, including: b the Easergy T200 E telecontrol interface, b MT switchgear that is adapted for telecontrol. PE56312 DE40901EN HV/MV RN2C RN2C RN2C MV ring L500 network monitoring screen Network control centre RN2C Communication network RN2C RN2C PE57073EN Easergy L500, a low cost solution to immediately improve your SAIDI (1) (1) SAIDI: system average interruption duration index Easergy L500 is a SCADA providing all the functions needed to operate the MV network in real time b Pre-confi gured with Easergy range products: v MV/LV substations equipped with T200 E or Flair 200C v overhead line equipped with Flite 116/G200 b Broad range of transmission supports: Radio, GSM, GPRS, PSTN, LL, FO. Advantages b Simple implementation: v one to two weeks only for 20 MV/LV substations v confi guration, training and handling within a few days b Short return on investment b Simple and fast evolutions by operations managers b Service quality and operations rapidly improved. AMTED399086EN.indd 13
16 Presentation Ringmaster selection guide PE57072 RN2c RE2c RN6c MU2 or MU6 CN2 SN6 CE2 CE6 SE6 200 A non extensible ring main unit 200 A extensible ring main unit 630 A non extensible ring main unit 200 A or 630 A feeder metering unit 200 A non extensible circuit breaker 630 A non extensible switch 200 A extensible circuit breaker 630 A extensible circuit breaker 630 A extensible switch Key to product references Ringmaster is available as standard panel types, allowing easy selection and specifi cation. The product references are made up as follows: R Ring main unit A C Circuit breaker A S Switch ka N Non-Extensible ka E Extensible MU Metering unit Example: CN2-T1/16 = circuit breaker, non extensible, 200 A, 16 ka fault rating. The Ringmaster catalogue allows easy selection and specifi cation, based on a broad range of worldwide applications. Included in this publication is: b panel type specifi cations b details of optional accessories b schematic diagrams b Installation drawings. Accessories Accessories for the Ringmaster range are supplied either fi tted or loose, where stated enabling simple panel confi guration on site. Details of accessories are contained within the panel type pages. General arrangement drawings General arrangement drawings are given for each panel type. This allows you to quickly size up switchrooms and calculate external connections at the pre-order stage. Need more information? If your requirements are not listed, please contact your local Schneider Electric representative, or contact us on: Tel: +44 (0) [email protected] Electronic catalogue requests Electronic copies of this selection guide are available free of charge upon request. For this, and other MV literature, please your full contact details to [email protected] 14 AMTED399086EN.indd
17 Ring main units Contents Non-extensible ring main units Specifi cation Accessories Non-extensible ring main units 200 A RN2c-T1, RN2c-T2, RN2c-T3, RN2c-T4, RN2c-T5, RN2c-T25 Non-extensible ring main units 630 A RN6c-T1, RN6c-T25 Extensible ring main units Specifi cation Accessories Extensible ring main units 200 A RE2c-T1, RE2c-T2, RE2c-T3, RE2c-T4, RE2c-T AMTED399086EN.indd 15
18 Ring main units Non-extensible ring main units Specification RN2c-T1 TFL RN2c-T2 VIP 300 RN2c-T3 VIP 30 RN2c-T4 VIP 35 RN2c-T5 Glass TFL RN2c-T25 Sepam 10 RN6c-T1 VIP 300 RN6c-T25 Sepam 10 Environment Indoor / outdoor b b b b b b b b IP54 b b b b b b b b Transformer mounted b b b b b b Freestanding O O O O O O b b Ratings Busbars 630 A b b b b b b b b Circuit breaker normal rated current 200 A b b b b b b Circuit breaker normal rated current 630 A b b Switch normal rated current 630 A b b b b b b b b 12 kv 16 ka 3 seconds 75 kv BIL b b b b b b b b 13.8 kv 21 ka 3 seconds 95 kv BIL O O O O O O O O Ring switch cable earth switch 16 ka 3 seconds b b b b b b b b Ring switch cable earth switch 21 ka 3 seconds O O O O O O O O Circuit breaker earth switch 3.15 ka b b b b b b b b Mechanism Independent manual b b b b b b b b Provision for motorised mechanism LH ring switch b b b b b b b b Provision for motorised mechanism RH ring switch b b b b b b b b Provision for motorised mechanism circuit breaker O O O O O O O O Protection & control - circuit breaker CT s dual ratio - 100/50/5 A class X b b CT s ratio - 200/1 A class X b CT s ratio - 200/100/1 5P20 b CT s ratio - 500/200/1 A class X b b CT s ratio - 800/400/1 A class X b CT s ratio - 800/400/1 5P20 b Overcurrent & earth fault CT operated trip coils - TFL b Overcurrent & earth fault CT operated trip coils - b b glass TFL Overcurrent relay - VIP 30 b Overcurrent & earth fault relay - VIP 35 b IDMT overcurrent & earth fault relay - VIP 300 b b IDMT Relay Sepam 10 b b Multi voltage shunt trip coil (see accessories page 17) O O O O O b O b Indication Mechanical ON/OFF b b b b b b b b Mechanical EARTH/MAIN b b b b b b b b VPIS indication kv O O O O O O O O Gas pressure indicator (-25 C to +55 C) b b b b b b b b RSW aux contacts 1NO & 1NC O O O O O O O O Test facility Integral ring cable test facility b b b b b b b b Integral circuit breaker test facility O O O O O O b b Standard features Operating handle b b b b b b b b Cable (see available cable kit accessories) Bottom entry up 1 x 3C 300 mm 2 b b b b b b b b Bottom entry up 3 x 1C 630 mm 2 b b b b b b b b Top entry cables (indoor only) O O O O O O O O Order codes 12 kv, 16 ka, 75 kv BIL, 0.55bG RN2c-T1/16 RN2c-T2/16 RN2c-T3/16 RN2c-T4/16 RN2c-T5/16 RN6c-T1/ kv, 21 ka, 95 kv BIL, 0.8bG RN2c-T1/21 RN2c-T2/21 RN2c-T3/21 RN2c-T4/21 RN2c-T5/21 RN2c-T25/21 RN6c-T1/21 RN6c-T25/21 General arrangement drawing - transformer mounted RMINST-06 Page 95 General arrangement drawing - freestanding Schematic diagram - TFL Schematic diagram - VIP 30 Schematic diagram - VIP 35 Schematic diagram - VIP 300 Schematic diagram - Sepam 10 Key: b Standard feature O Optional feature RMINST-05 Page 144 RMSCH-01 Page 104 RMINST-06 Page 95 RMINST-05 Page 144 RMSCH-03 Page 106 RMINST-06 Page 95 RMINST-05 Page 144 RMSCH-02 Page 105 RMINST-06 Page 95 RMINST-05 Page 144 RMSCH-15 Page 107 RMINST-06 Page 95 RMINST-05 Page 144 RMSCH-01 Page 104 RMINST-06 Page 95 RMINST-05 Page 144 RMINST-06 Page 95 RMINST-05 Page 144 RMSCH-42 Page 112 RMSCH Pages RMINST-06 Page 95 RMINST-05 Page 144 RMSCH Pages AMTED399086EN.indd
19 Ring main units Non-extensible ring main units Accessories RN2c-T1 TFL RN2c-T2 VIP 300 RN2c-T3 VIP 30 RN2c-T4 VIP 35 RN2c-T5 RN2c-T25 Glass TFL Sepam 10 RN6c-T1 VIP 300 RN6c-T25 Sepam 10 Cable kits Circuit breaker cable box v v v v v v RMR-A/F47 Circuit breaker cable box with integral cable test facility v v v v v v b b RMR-F325 Gland plate 1 x 3C O O O O O O O O RMR-A316 Gland plate 3 x 1C O O O O O O O O RMR-A319 Small gland plate 1 x 3C O O O O O O O O RMR-A322 Blank aluminium gland plate O O O O O O O O RMR-A320 Brass wiping gland 1 x 3C O O O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O O O O O RMR-A11 Small brass wiping gland 1 x 3C O O O O O O O O RMR-A105 Tubular gland 1 x 3C O O O O O O O O RMR-A12 Tubular gland 3 x 1C O O O O O O O O RMR-A13 Small tubular gland O O O O O O O O RMR-A106 CES5 gland O O O O O O O O RMR-A120 CES5 gland plate 1 x 3C O O O O O O O O RMR-A321 CES5 gland adaptor O O O O O O O O RMR-A525 6 x ECON cable termination kit O O O O O O O O RMR-A314 3 x STD ECON end cap O O O O O O O O RMR-A370 3 x ECON cable termination kit O O O O O O O O RMR-A315 Top entry cables RH cable box (indoor only) v v v v v v v v RMR-F303 Top entry cables LH cable box (indoor only) v v v v v v v v RMR-F302 Rsw extension box for 2 x 3C cables (left hand) v v v v v v v v RMR-F523 Rsw extension box for 2 x 3C (right hand) v v v v v v v v RMR-F522 Angled gland plate 1 x 3C O O O O O O O O RMR-A317 Split gland plate 1 x 3C O O O O O O O O RMR-A318 Installation items Transformer mounting kit v v v v v v v v RMR-A/F323 Extension trunking (to clear transformer radiators) O O O O O O O O RMR-A20 Set of padlocks - 11 no O O O O O O O O RMR-A343 Anti-vandal fi xings, including tool O O O O O O O O RMR-A344 Foundation bolts (not required for transformer mounting) O O O O O O O O RMR-A22 Multicore pilot glands O O O O O O O O RMR-A342 Time limit fuses (set of 2 - specify rating as table page 143) O O O O O O O O RMR-A17 RN2c to MU2 installation kit v v v v v v v v RMR-A350 Ariel mounting bracket O O O O O O O O RMR-A201 Operational items Operating handle b b b b b b b b RMR-F345 LH ring switch control auxiliary sw for motorised v v v v v v v v RMR-F328 mechanism provision LH ring switch termination block for motorised v v v v v v v v RMR-F363 mechanism provision (not Easergy) RH ring switch control auxiliary sw for motorised v v v v v v v v RMR-F329 mechanism provision RH ring switch termination block for motorised v v v v v v v v RMR-F364 mechanism provision (not Easergy) Provision for motorised mechanism circuit breaker v v v v v v b b RMR-F543 Motorised mechanism - specify voltage v v v v v v v v RMR-F507 CB Termination block for motorised v v v v v v v v RMR-F365 mechanism provision (not Easergy) Shunt trip coil ( V DC, V AC) TLF v v v v v v v v RMR-F581 Shunt trip coil ( V DC, V AC) VIP v v v v v v v v RMR-F582 Ring switch cable VPIS indication ( kv) v v v v v v v v RMR-F341 Circuit breaker cable VPIS indication ( kv) v v v v v v v v RMR-F340 Circuit breaker cable VPIS indication ( kv) v v v v v v v v RMR-F347 Phase indication device O O O O O O O O RMR-A374 VAP 6 test unit for VIP 300/30/35 O O O O O O O O RMR-A202 Emergency trip push button v v v v v v v v RMR-F339 Gas pressure switch for remote indication only v v v v v v v v RMR-F368 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site Kit no. AMTED399086EN.indd 17
20 Ring main units Non-extensible ring main units Accessories RN2c-T1 TFL RN2c-T2 VIP 300 RN2c-T3 VIP 30 RN2c-T4 VIP 35 RN2c-T5 RN2c-T25 Glass TFL Sepam 10 RN6c-T1 VIP 300 RN6c-T25 Sepam 10 Mechanical interlocks Circuit breaker - key free, EARTH ON v v v v v v v v RMR-F337 Circuit breaker - key free, MAIN OFF v v v v v v v v RMR-F338 Switch - key free, SWITCH OFF LH v v v v v v v v RMR-F335 Switch - key free, SWITCH OFF RH v v v v v v v v RMR-F336 N. B. specify lock symbol at time of ordering (3 digits max) not available with motor mechanisms Earth fault passage indication (choose provision kit and an EFPI required if not using Easergy T200E) Phase & earth fault provision for Easergy T200E O O O O O O O O RMR-F310 EFPI provision kit, inside cable box O O O O O O O O RMR-A304 EFPI provision kit, CT outside cable box O O O O O O O O RMR-A305 EFPI provision kit, inside cable box, top entry O O O O O O O O RMR-A308 EFPI provision kit, outside cable box, top entry O O O O O O O O RMR-A309 Bowden RR EFPI and CT O O O O O O O O RMR-A422 Bowden STD EFPI type NB O O O O O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O O O O O RMR-A278 Bowden LV reset & alarm type NB2 O O O O O O O O RMR-A279 Fundamentals ER FIND EFPI and CT O O O O O O O O RMR-A57 N. B. above CT s are ring type for split core - please consult Schneider Electric Key: v Factory fi tted accessory O Loose accessory, assembled on site Kit no. 18 AMTED399086EN.indd
21 Ring main units Non-extensible ring main unit 200 A RN2c-T1 DE60180 DE60181 Transformer protection up to 1.6 MVA at 11 kv Protection & control - CB Overcurrent and earth fault protection using CT operated trip coils with provision for time fuse links Protection CT s - 100/50/5 A class X Transformer ratings See table - page 147 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-01 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch with plug interface Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 17 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable boxes (indoor only) Transformer mounting kit Freestanding tee-off cable box Order information Code RN2c-T1/16 RN2c-T1/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 19
22 Ring main units Non-extensible ring main unit 200 A RN2c-T2 DE60180 DE60185 Transformer protection up to 3.5 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142 Protection CT s - 200/1 A class X b Setting range: v Overcurrent: A v Earth fault: A Transformer ratings See table - page 147 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-03 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch with plug interface Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 17 CB LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable boxes (indoor only) Transformer mounting kit Freestanding tee-off cable box Order information Code RN2c-T2/16 RN2c-T2/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 20 AMTED399086EN.indd
23 Ring main units Non-extensible ring main unit 200 A RN2c-T3 DE60180 DE60182 MV transformer protection Protection & control - CB Self powered overcurrent relay, VIP 30. Protection CT s - 500/200/1 A class X b Setting range: 500/1 A v Overcurrent: A b Setting range: 200/1 A v Overcurrent: 8-80 A Transformer ratings See table - page 147 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-02 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch with plug interface Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 17 CB, LH, RH motor kit LH, RH ring switch indication 1NO 1NC earth On 1NO Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable box (indoor only) Transformer mounting kit Freestanding tee-off cable box Order information Code RN2c-T3/16 RN2c-T3/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 21
24 Ring main units Non-extensible ring main unit 200 A RN2c-T4 DE60180 DE60183 MV transformer protection Protection & control - CB Self powered overcurrent and earth fault relay, VIP 35. Protection CT s - 500/200/1 A class X CH30 core balance CT b Setting range: 500/1 A v Overcurrent: A v Earth fault: A b Setting range: 200/1 A v Overcurrent: 8-80 A v Earth fault: A Transformer ratings See table - page 147 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-15 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch with plug interface Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 17 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable boxes (indoor only) Transformer mounting kit Freestanding tee-off cable box Order information Code RN2c-T4/16 RN2c-T4/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 22 AMTED399086EN.indd
25 Ring main units Non-extensible ring main unit 200 A RN2c-T5 DE60180 DE60184 Transformer protection up to 1.6 MVA at 11 kv Protection & control - CB Overcurrent and earth fault protection using CT operated trip coils with provision for time fuse links (glass fuse link) Protection CT s - 100/50/5 A class X Transformer ratings See table - page 147 Documents Transformer mounted installation drawing ref: RMINST-06 Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-01 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch with plug interface Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 17 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable boxes (indoor only) Transformer mounting kit Freestanding tee off cable box Order information Code RN2c-T5/16 RN2c-T5/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 23
26 Ring main units Non-extensible ring main unit 200 A RN2c-T25 DE60180 DE59800 Sepam 10 functions Protection Earth-fault protection 50/51 50N/51N 49RMS ANSI code RN2c-T25 (1) B BS A AS Standard 50N/51N b b In (2) Sensitive 50G/51G b b A Phase-overcurrent protection 50/51 b b b b I (3) Thermal overload protection 49RMS b b b b Phase-overcurrent and b b b b earth-fault cold load pick-up Logic Blocking send 68 b b b b discrimination Blocking reception b b External tripping via digital input b b Measurement Earth-fault current b b b b Phase currents b b b b Peak demand currents b b b b Control and supervision Circuit breaker tripping 86 b b b b and lockout Tripping annunciation 30 b b b b Tripped on fault, volt free contact b b b b Relay watchdog contact b b Remote CB position monitoring b b Record of last fault b b b b Record of last fi ve events b b Communications Modbus b b IEC b b (1) B (basic), BS (basic + sensitive earth-fault), A (advanced), AS (advanced + sensitive earth-fault) (2) In = Primary CT ratio (3) Only with T25B and T25BS (4) BS + AS not available with transformer mounted units. Transformer protection up to 3.5 MVA at 11 kv Protection & control - CB IDMT overcurrent, earth-fault and thermal overload relay, Sepam series 10. In accordance with IEC Power supply VDC required Protection CT s - 200/100/1 A 5P20 Setting range (200/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Setting range (100/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Documents (1) Schematic drawing ref: RN2c-T25B: RMSCH-43 RN2c-T25BS: RMSCH-44 RN2c-T25A: RMSCH-45 RN2c-T25AS: RMSCH-46 Environment Indoor/outdoor IP54 Ratings Busbar 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring switch cable earth switch, 16/21 ka 3 s Transformer earth switch, 16/21 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch Multi voltage shunt trip coil V DC V AC/DC Indication Mechanical tripped on fault fl ag indication Mechanical ON/OFF indication Mechanical earth/main indication Gas pressure indication CB auxiliary contacts 1NO 1NC (3) CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm² Bottom entry up to 3 x 1C 630 mm² Accessories - see table, page 17 CB, LH, RH motor kit RH and LH ring switch indication auxiliary contacts 1NO 1NC Earth ON auxiliary contact 1NO VPIS indication Inverted cable box (indoor only) Transformer mounting kit (4) Freestanding tee-off cable box Order information Code (1) RN2c-T25B/21 RN2c-T25BS/21 RN2c-T25A/21 RN2c-T25AS/21 Rating 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 24 AMTED399086EN.indd
27 Ring main units Non-extensible ring main unit 630 A RN6c-T1 DE60180 DE60186 Network sectionalising up to 12 MVA 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142 Protection CT s - 800/400/1 A class X b Setting range: 800/1 A ratio v Overcurrent: A v Earth fault: A b Setting range: 400/1 A v Overcurrent: A v Earth fault: A Documents Freestanding installation drawing ref: RMINST-05 Schematic drawing ref: RMSCH-42 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/630 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Circuit breaker earth switch 16/21 ka Ring cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch and circuit breaker with plug interface Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch and circuit breaker test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 17 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable boxes (indoor only) Freestanding Order information Code RN6c-T1/16 RN6c-T1/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 25
28 Ring main units Non-extensible ring main unit 630 A RN6c-T25 DE60180 DE59800 Sepam 10 functions Protection Earth-fault protection 50/51 50N/51N 49RMS ANSI code RN6c-T25 (1) B BS A AS Standard 50N/51N b b In (2) Sensitive 50G/51G b b A Phase-overcurrent protection 50/51 b b b b In (2) Thermal overload protection 49RMS b b b b Phase-overcurrent and b b b b earth-fault cold load pick-up Logic Blocking send 68 b b b b discrimination Blocking reception b b External tripping via digital input b b Measurement Earth-fault current b b b b Phase currents b b b b Peak demand currents b b b b Control and supervision Circuit breaker tripping 86 b b b b and lockout Tripping annunciation 30 b b b b Tripped on fault, volt free contact b b b b Relay watchdog contact b b Remote CB position monitoring b b Record of last fault b b b b Record of last fi ve events b b Communications Modbus b b IEC b b (1) B (basic), BS (basic + sensitive earth-fault), A (advanced), AS (advanced + sensitive earth-fault) (2) In = Primary CT ratio (3) Only with T25B and T25BS (4) BS + AS not available with transformer mounted units. Network sectionalising up to 12 MVA at 11 kv Protection & control - CB IDMT overcurrent, earth-fault and thermal overload relay, Sepam series 10. In accordance with IEC Power supply VDC required Protection CT s - 800/400/1 A 5P20 Setting range (800/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Setting range (400/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Documents (1) Schematic drawing ref: RN6c-T25B: RMSCH-43 RN6c-T25BS: RMSCH-44 RN6c-T25A: RMSCH-45 RN6c-T25AS: RMSCH-46 Environment Indoor/outdoor IP54 Ratings Busbar 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring switch cable earth switch, 16/21 ka 3 s Transformer earth switch, 16/21 ka 3 s Anti-refl ex operating handle Provision for motorised mechanism LH/RH ring switch Multi voltage shunt trip coil V DC V AC/DC Indication Mechanical tripped on fault fl ag indication Mechanical ON/OFF indication Mechanical earth/main indication Gas pressure indication CB auxiliary contacts 1NO 1NC (3) CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm² Bottom entry up to 3 x 1C 630 mm² Accessories - see table, page 17 CB, LH, RH motor kit RH and LH ring switch indication auxiliary contacts 1NO 1NC Earth ON auxiliary contact 1NO VPIS indication Inverted cable box (indoor only) Transformer mounting kit (4) Freestanding tee-off cable box Order information Code (1) RN6c-T25B/21 RN6c-T25BS/21 RN6c-T25A/21 RN6c-T25AS/21 Rating 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 26 AMTED399086EN.indd
29 Ring main units Extensible ring main units Specification RE2c-T1 TFL RE2c-T2 VIP 300 RE2c-T3 VIP 30 RE2c-T4 VIP 35 RE2c-T25 Sepam 10 Environment Indoor / outdoor b b b b b IP54 b b b b b Transformer mounted b b b b b Freestanding b b b b b Extensible (RHS) O O O O O Ratings Busbars 630 A b b b b b Circuit breaker normal rated current 200 A b b b b b Circuit breaker normal rated current 630 A Switch normal rated current 630 A b b b b b 12 kv 16 ka 3 seconds 75 kv BIL b b b b b 13.8 kv 21 ka 3 seconds 95 kv BIL O O O O O Ring switch cable earth switch 16 ka 3 seconds b b b b b Ring switch cable earth switch 21 ka 3 seconds O O O O O Circuit breaker earth switch 3.15 ka b b b b b Extensible rmu busbar chamber 630 A O O O O O Mechanism Independent manual b b b b b Provision for motorised mechanism LH ring switch b b b b b Provision for motorised mechanism RH ring switch b b b b b Provision for motorised mechanism circuit breaker O O O O O Protection & control - circuit breaker CT s dual ratio - 100/50/5 A class X b CT s ratio - 200/1 A class X b CT s dual ratio 200/100/1 A 5P20 b CT s ratio - 500/200/1 A class X b b Overcurrent & earth fault CT operated trip coils - TFL b Overcurrent relay - VIP 30 b Overcurrent & earth fault relay - VIP 35 b IDMT overcurrent & earth fault relay - VIP 300 b IDMT relay Sepam 10 b Multi voltage shunt trip coil (see accessories) O O O O b Indication Mechanical ON/OFF b b b b b Mechanical EARTH/MAIN b b b b b VPIS indication kv O O O O O Gas pressure indicator (-25 C to +55 C) b b b b b RSW aux contacts 1NO & 1NC O O O O O Test facility Integral ring cable test facility b b b b b Standard features Operating handle b b b b b Cable (see available cable kit accessories) Bottom entry up 1 x 3C 300 mm 2 b b b b b Bottom entry up 3 x 1C 630 mm 2 b b b b b Top entry cables (indoor only) (left hand side only) O O O O O Order codes 12 kv, 16 ka, 75 kv BIL, 0.35bG RE2c-T1/16 RE2c-T2/16 RE2c-T3/16 RE2c-T4/ kv, 21 ka, 95 kv BIL, 0.8bG RE2c-T1/21 RE2c-T2/21 RE2c-T3/21 RE2c-T4/21 RE2c-T25/21 General arrangement drawing - freestanding Schematic diagram - TFL Schematic diagram - VIP 30 Schematic diagram - VIP 35 Schematic diagram - VIP 300 Schematic diagram Sepam 10 Key: b Standard feature O Optional feature RMINST-22 Page 94 RMSCH-01 Page 104 RMINST-22 Page 94 RMSCH-03 Page 106 RMINST-22 Page 94 RMSCH-02 Page 105 RMINST-22 Page 94 RMSCH-15 Page 107 RMINST-22 Page 94 RMSCH Pages AMTED399086EN.indd 27
30 Ring main units Extensible ring main units Accessories RE2c-T1 TFL RE2c-T2 VIP 300 RE2c-T3 VIP 30 RE2c-T4 VIP 35 RE2c-T25 Sepam 10 Cable kits Extensible ring main units v v v v v RMR-A/F47 Gland plate 1 x 3C O O O O O RMR-A316 Gland plate 3 x 1C O O O O O RMR-A319 Small gland plate 1 x 3C O O O O O RMR-A322 Blank aluminium gland plate O O O O O RMR-A320 Brass wiping gland 1 x 3C O O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O O RMR-A10 Small brass wiping gland 1 x 3C O O O O O RMR-A105 Tubular gland 1 x 3C O O O O O RMR-A12 Tubular gland 3 x 1C O O O O O RMR-A13 Small tubular gland 1 x 3C O O O O O RMR-A106 CES5 gland O O O O O RMR-A120 CES5 gland plate 1 x 3C O O O O O RMR-A321 CES5 gland plate adaptor O O O O O RMR-A525 6 x ECON cable termination kit O O O O O RMR-A314 3 x STD ECON end cap O O O O O RMR-A370 3 x ECON cable termination kit O O O O O RMR-A315 3 x ECON end cap capacitors O O O O O RMR-A371 Top entry cables LH cable box (indoor only) v v v v v RMR-F302 Angled gland plate 1 x 3C O O O O O RMR-A317 Split gland plate 1 x 3C O O O O O RMR-A318 Installation items Transformer mounting kit v v v v v RMR-A/F323 Extension trunking (to clear radiators) O O O O O RMR-A20 Set of padlocks - 11 no O O O O O RMR-A343 Anti-vandal fi xings, including tool O O O O O RMR-A344 Foundation bolts (not required for transformer mounting) O O O O O RMR-A22 Multicore pilot glands O O O O O RMR-A342 Time limit fuses (set of 2 - specify rating as table page 115) O O O O O RMR-A17 RE2c to MU2 installation kit v v v v v RMR-A350 Extensible busbar chamber 630 A O O O O O RMR-F369 Ariel mounting bracket O O O O O RMR-A201 Operational items Operating handle b b b b b RMR-F345 LH ring switch control auxiliary sw for motorised mechanism v v v v v RMR-F328 provision LH ring switch termination block for motorised mechanism v v v v v RMR-F363 provision (not Easergy) RH ring switch control auxiliary sw for motorised mechanism v v v v v RMR-F329 provision RH ring switch termination block for motorised mechanism v v v v v RMR-F364 provision (not Easergy) Provision for motorised mechanism circuit breaker v v v v v RMR-F543 Motorised mechanism - specify voltage v v v v v RMR-F507 Shunt trip coil ( V DC, V AC) TLF v v v v v RMR-F581 Shunt trip coil ( V DC, V AC) VIP v v v v v RMR-F582 Ring switch cable VPIS indication ( kv) v v v v v RMR-F341 Circuit breaker VPIS indication ( kv) v v v v v RMR-F340 Circuit breaker VPIS indication ( kv) v v v v v RMR-F347 VAP 6 test unit for VIP 300/30/35 v v v v v RMR-A202 Emergency trip push button v v v v v RMR-F339 Gas pressure switch for remote indication only v v v v v RMR-F368 Key: b Standard feature v Factory fitted accessory O Loose accessory, assembled on site Kit no. 28 AMTED399086EN.indd
31 Ring main units Extensible ring main units Accessories RE2c-T1 TFL RE2c-T2 VIP 300 RE2c-T3 VIP 30 RE2c-T4 VIP 35 RE2c-T25 Sepam 10 Kit no. Mechanical interlocks Circuit breaker - key free, earth on v v v v v RMR-F337 Circuit breaker - key free, main off v v v v v RMR-F338 Switch - key free, switch off LH v v v v v RMR-F335 Switch - key free, switch off RH v v v v v RMR-F336 N. B. specify lock symbol at time of ordering (3 digits max) not available with motor mechanisms Earth fault passage indication (choose provision kit and an EFPI required if not using Easergy T200E) Phase & earth fault provision for Easergy T200E O O O O O RMR-F310 EFPI provision kit, inside cable box O O O O O RMR-A304 EFPI provision kit, CT outside cable box O O O O O RMR-A305 EFPI provision kit, inside cable box, top entry O O O O O RMR-A308 EFPI provision kit, outside cable box, top entry O O O O O RMR-A309 Bowden RR EFPI and CT O O O O O RMR-A422 Bowden STD EFPI type NB O O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O O RMR-A278 Bowden LV reset & alarm type NB O O O O O RMR-A279 Fundamentals ER FIND EFPI and CT O O O O O RMR-A57 N. B. above CT s are ring type for split core - please consult Schneider Electric Key: v Factory fi tted accessory O Loose accessory, assembled on site AMTED399086EN.indd 29
32 Ring main units Extensible ring main unit 200 A RE2c-T1 DE60211 DE60187 Multiple transformer feeders or network switching points Protection & control - CB Overcurrent and earth fault protection using CT operated trip coils with provision for time fuse links. Protection CT s - 100/50/5 A class X Transformer ratings See table - page 147 Documents Freestanding installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-01 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring switch cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Extensible (RHS) Extensible (LHS and RHS) Provision for motorised mechanism LH/RH ring switch with plug interface Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 28 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC earth On 1NO Multi voltage shunt trip coil V DC V AC/DC VPIS indication Integral circuit breaker test facility Inverted cable boxes LH, CB (indoor only) Transformer mounting kit Freestanding tee-off cable box Order information Code RE2c-T1/16 RE2c-T1/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 30 AMTED399086EN.indd
33 Ring main units Extensible ring main unit 200 A RE2c-T2 DE60211 DE60188 Multiple transformer feeders or network switching points Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS 142. Protection CT s - 200/1 A class X b Setting range: v Overcurrent: A v Earth fault: A Transformer ratings See table - page 147 Documents Installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-03 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring switch cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Extensible (RHS) Provision for motorised mechanism LH/RH ring switch Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 28 CB, LH, RH motor kits LH, RH ring switch indication 1NO 1NC Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable box LH CB (indoor only) Transformer mounting kit Freestanding tee-off cable box Order information Code RE2c-T2/16 RE2c-T2/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 31
34 Ring main units Extensible ring main unit 200 A RE2c-T3 DE60211 DE60189 MV transformer protection Protection & control - CB Self powered overcurrent relay, VIP 30. Protection CT s - 500/200/1 A class X b Setting range: 500/1 A v Overcurrent: A b Setting range: 200/1 A v Overcurrent: 8-80 A Transformer ratings See table - page 147 Documents Installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-02 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring switch cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka Anti-refl ex operating handle Extensible (RHS) Provision for motorised mechanism LH/RH ring switch Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table, page 28 CB, LH, RH motor kit LH, RH ring switch indication 1NO 1NC Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable boxes LH, CB (indoor only) Transformer mounting kit Freestanding tee-off cable box Order information Code RE2c-T3/16 RE2c-T3/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 32 AMTED399086EN.indd
35 Ring main units Extensible ring main unit 200 A RE2c-T4 DE60211 DE60190 MV transformer protection Protection & control - CB Protection & control - CB Self powered overcurrent and earth fault relay, VIP 35. Protection CT s - 500/200/1 A class with CH30 core balance CT b Setting range: 500/1 A v Overcurrent: A v Earth fault A b Setting range: 200/1 A v Overcurrent: 8-80 A v Earth fault A Transformer ratings See table - page 147 Documents Installation drawing ref: RMINST-22 Schematic drawing ref: RMSCH-15 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring switch cable earth switch, 16/21 ka 3 s Transformer earth switch, 3.15 ka 3 s Anti-refl ex operating handle Extensible (RHS) Provision for motorised mechanism LH/RH ring switch Indication Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 1NC Earth position selected 1NO Earth ON, 1NO Test facility Integral ring switch test facility Cable Bottom entry up to 1 x 3C 300 mm 2 Bottom entry up to 3 x 1C 630 mm 2 Accessories - see table page 28 CB, LH, RH motor kit LH, RH ring switch indication 1NO 1NC Multi voltage shunt trip coil V DC V AC/DC VPIS indication Inverted cable boxes LH, CB (indoor only) Transformer mounting Freestanding tee-off cable box Order information Code RE2c-T4/16 RE2c-T4/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 33
36 Ring main units Extensible ring main unit 200 A RE2c-T25 DE60211 DE59801 Sepam 10 functions Protection Earth-fault protection 50/51 50N/51N 49RMS ANSI code 50/51 50N/51N 49RMS RE2c-T25 (1) B BS A AS Standard 50N/51N b b In (2) Sensitive 50G/51G b b A Phase-overcurrent protection 50/51 b b b b In (2) Thermal overload protection 49RMS b b b b Phase-overcurrent and b b b b earth-fault cold load pick-up Logic Blocking send 68 b b b b discrimination Blocking reception b b External tripping via digital input b b Measurement Earth-fault current b b b b Phase currents b b b b Peak demand currents b b b b Control and supervision Circuit breaker tripping 86 b b b b and lockout Tripping annunciation 30 b b b b Tripped on fault, volt free contact b b b b Relay watchdog contact b b Remote CB position monitoring b b Record of last fault b b b b Record of last fi ve events b b Communications Modbus b b IEC b b (1) B (basic), BS (basic + sensitive earth-fault), A (advanced), AS (advanced + sensitive earth-fault) (2) In = Primary CT ratio (3) Only with T25B and T25BS (4) BS + AS not available with transformer mounted units. MV transformer protection Protection & control - CB IDMT overcurrent, earth-fault and thermal overload relay, Sepam series 10. In accordance with IEC Power supply VDC required Protection CT s - 200/100/1 A 5P20 Setting range (200/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Setting range (100/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Documents (1) Schematic drawing ref: RN2c-T25B: RMSCH-43 RN2c-T25BS: RMSCH-44 RN2c-T25A: RMSCH-45 RN2c-T25AS: RMSCH-46 Environment Indoor/outdoor IP54 Ratings Busbar 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A/200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Ring switch cable earth switch, 16/21 ka 3 s Transformer earth switch, 16/21 ka 3 s Anti-refl ex operating handle Extensible RHS Provision for motorised mechanism LH/RH ring switch Multi voltage shunt trip coil V DC V AC/DC Indication Mechanical tripped on fault fl ag indication Mechanical ON/OFF indication Mechanical earth/main indication Gas pressure indication CB auxiliary contacts 1NO 1NC (3) CB earth position selected 1NO CB earth ON, 1NO Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm² Bottom entry up to 3 x 1C 630 mm² Accessories - see table, page 28 CB, LH, RH motor kit RH and LH ring switch indication auxiliary contacts 1NO 1NC Earth ON auxiliary contact 1NO VPIS indication Inverted cable box (indoor only) Transformer mounting kit (4) Freestanding tee-off cable box Order information Code (1) Rating RN2c-T25B/21 21 ka, 13.8 kv, 95 kv BIL RN2c-T25BS/21 21 ka, 13.8 kv, 95 kv BIL RN2c-T25A/21 21 ka, 13.8 kv, 95 kv BIL RN2c-T25AS/21 21 ka, 13.8 kv, 95 kv BIL 34 AMTED399086EN.indd
37 Circuit breaker, metering and switches Contents Non-extensible circuit breakers 200 A Specifi cation - Accessories CN2-T1, CN2-T6, CN2-T25 Non-extensible switches 630 A Specifi cation - Accessories SN6-S1, SN6-S2 Non-extensible metering units 200 A Specifi cation - Accessories MU2-M1, MU2-M2, MU2-M3 Non-extensible metering units 630 A Specifi cation - Accessories MU6-N** Extensible circuit breakers 200 A Specifi cation - Accessories CE2-T2, CE2-T7, CE2-T*, CE2-T12, CE2-T**, CE2-T13, CE2-T15, CE2-T16, CE2-T25 Extensible circuit breakers 630 A Specifi cation - Accessories CE6-T4, CE6-T*, CE6-T8, CE6-T25, CE6-T** Extensible switches 630 A Specifi cation - Accessories SE6-S1, SE6-S2, SE6-E1 Extensible bus-section 630 A Specifi cation - Accessories SE6-B1, CE6-B3, CE6-B AMTED399086EN.indd 35
38 Circuit breaker, metering and switches Non-extensible circuit breakers 200 A Specification CN2-T1 CN2-T6 CN2-T25 Environment Indoor / outdoor b b b IP54 b b b Ratings Normal rated current 200 A b b b 12 kv 16 ka 3 seconds 75 kv BIL b b b 13.8 kv 21 ka 3 seconds 95 kv BIL O O O Cable earth switch 16 ka 3 seconds b b b Cable earth switch 21 ka 3 seconds O O O Transformer earth switch 3.15 ka 3 seconds b b b Mechanism Independent manual b b b Protection & control - circuit breaker CT s dual ratio - 100/50/5 A class X b b CT s ratio - 200/1 A class X b CT s dual ratio 200/100/1 A 5P20 b Overcurrent & earth fault CT operated trip coils b b Time fuse Link O O IDMT overcurrent & earth fault relay - VIP 300 b IDMT overcurrent and earth fault relay Sepam 10 b 20 V-250 shunt trip coil b b b Circuit breaker auxiliary switch 1NO 2NC b b b Indication Mechanical ON/OFF b b b Mechanical EARTH/MAIN b b b VPIS indication ( kv) O O O Auxiliary switch contacts 1NO 2NC b b b Gas pressure indicator b b b Test facility Integral cable test facility b b b Standard features Operating handle b b b Transformer earth switch 3.15 ka 3 seconds b b b Cable (see available cable kit accessories) Bottom entry up 300 mm 2 1 x 3C b b b Bottom entry up 630 mm 2 3 x 1C b b b Key: b Standard feature O Optional feature 36 AMTED399086EN.indd
39 Circuit breaker, metering and switches Non-extensible circuit breakers 200 A Accessories CN2-T1 CN2-T6 CN2-T25 Kit no. Cable kits Tee-off cable box v v v RMR-F47 Gland plate 1 x 3C O O O RMR-A48 Gland plate 3 x 1C O O O RMR-A49 Angled gland plates (RMR) O O O RMR-A50 Blank Blank aluminium gland plate O O O RMR-A52 Brass wiping gland 1 x 3C O O O RMR-A10 Brass wiping gland 3 x 1C O O O RMR-A11 Tubular gland 1 x 3C O O O RMR-A12 Tubular gland 3 x 1C O O O RMR-A13 CES5 gland plate 1 x 3C O O O RMR-A132 Installation items Set of padlocks - 6 no O O O RMR-A18/6 Anti-vandal fi xings, including tool O O O RMR-A19 Foundation bolts (not required for transformer mounting) O O O RMR-A22 Multicore pilot glands O O O RMR-A16 Time limit fuses (set of 2 - specify rating as table page 115) O O RMR-A17 Operational items Operating handle b b b RMR-A23 VPIS indication ( kv) v v v RMR-F108 Neon lamp test unit (including lamp) O O O RMR-A24 Neon lamp O O O RMR-A81 VAP 6 test unit for VIP 300 O RMR-A202 Mechanical interlocks Key free, earth on v v v RMR-F85 Key free, unit off v v v RMR-F86 Transformer earth switch, key free, earth on v v v RMR-F110 N. B. specify lock symbol at time of ordering (3 digits max) not available with motor mechanisms Order codes 12 kv, 16 ka, 75 kv BIL, 0.35bG CN2-T1/16 CN2-T6/ kv, 21 ka, 95 kv BIL, 0.55bG CN2-T1/21 CN2-T6/21 CN2-T25/21 General arrangement drawing - transformer mounted RMINST-04 Page 93 RMINST-04 Page 93 RMINST-04 Page 93 General arrangement drawing - freestanding RMINST-09 Page 145 RMINST-09 Page 145 RMINST-09 Page 145 Schematic diagram RMSCH-26 Page 119 RMSCH-11 Page 118 RMSCH-47 to 50 Page 114 to 117 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site AMTED399086EN.indd 37
40 Circuit breaker, metering and switches Non-extensible circuit breaker 200 A CN2-T1 DE60250 Transformer protection up to 3.5 MVA Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142 Protection CT s - 200/1 A class X b Setting range: v Overcurrent: A v Earth fault: A Shunt trip coil, 20 V DC-250 V AC Transformer ratings See table - page 147 Documents Transformer mounted installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cable box ref: RMINST-09 Schematic drawing ref: RMSCH-26 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Tee-off earth switch, 3.15 ka 3 s Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 2 NC Test facility Integral cable test facilities Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Tee-off cable box Glands and plates Interlocks See page 37 for details Order information Code CN2-T1/16 CN2-T1/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 38 AMTED399086EN.indd
41 Circuit breaker, metering and switches Non-extensible circuit breaker 200 A CN2-T6 DE60192 Transformer protection up to 1.5 MVA Protection & control - CB Overcurrent and earth fault protection using CT operated trip coils with provision for time fuse links. Protection CT s - 100/50/5 A class X Shunt trip coil, 20 V DC-250 V AC Transformer ratings See table - page 147 Documents Transformer mounted installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cable box ref: RMINST-09 Schematic drawing ref: RMSCH-11 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Transformer earth switch, 3.15 ka 3 s Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator CB auxiliary contacts 1NO 2 NC Test facility Integral cable test facilities Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Tee-off cable box Glands and plates Interlocks See page 37 for details Order information Code CN2-T6/16 CN2-T6/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 39
42 Circuit breaker, metering and switches Non-extensible circuit breaker 200 A CN2-T25 DE59802 Sepam 10 functions Protection Earth-fault protection 50/51 50N/51N 49RMS ANSI code CN2-T25 (1) B BS A AS Standard 50N/51N b b In (2) Sensitive 50G/51G b b A Phase-overcurrent protection 50/51 b b b b In (2) Thermal overload protection 49RMS b b b b Phase-overcurrent and b b b b earth-fault cold load pick-up Logic Blocking send 68 b b b b discrimination Blocking reception b b External tripping via digital input b b Measurement Earth-fault current b b b b Phase currents b b b b Peak demand currents b b b b Control and supervision Circuit breaker tripping 86 b b b b and lockout Tripping annunciation 30 b b b b Tripped on fault, volt free contact b b b b Relay watchdog contact b b Remote CB position monitoring b b Record of last fault b b b b Record of last fi ve events b b Communications Modbus b b IEC b b (1) B (basic), BS (basic + sensitive earth-fault), A (advanced), AS (advanced + sensitive earth-fault) (2) In = Primary CT ratio (3) Only with T25B and T25BS. Transformer protection up to 3.5 MVA Protection & control - CB IDMT overcurrent, earth-fault and thermal overload relay, Sepam series 10. In accordance with IEC Power supply VDC required Protection CT s - 200/100/1 A 5P20 Setting range (200/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Setting range (100/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Documents (1) Schematic drawing ref: CN2-T25B: RMSCH-47 CN2-T25BS: RMSCH-48 CN2-T25A: RMSCH-49 CN2-T25AS: RMSCH-50 Environment Indoor/outdoor IP54 Ratings Busbar 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Transformer earth switch, 3.15 ka 3 s Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indication Mechanical ON/OFF indication Mechanical earth/main indication Gas pressure indication CB auxiliary contacts 1NO 1NC (3 Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm² Bottom entry up to 3 x 1C 630 mm² Accessories - see table, page 37 Tee-off cable box Glands and plates Interlocks Order information Code (1) CN2-T25B/21 CN2-T25BS/21 CN2-T25A/21 CN2-T25AS/21 Rating 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 40 AMTED399086EN.indd
43 Circuit breaker, metering and switches Non-extensible switches 630 A Specification SN6-S1 SN6-S2 Environment Indoor / outdoor b b IP54 b b Ratings Normal rated current 630 A b b 13.8 kv 21 ka 3 seconds 95 kv BIL b b Cable earth switch 21 ka 3 seconds b b Transformer earth switch 3.15 ka 3 seconds b b Mechanism Independent manual b b Provision for actuator 24 V DC b Actuator 24 V DC O Indication Mechanical ON/OFF b b Mechanical EARTH/MAIN b b VPIS indication ( kv) O O Auxiliary switch contacts 1NO 2NC b Phase and earth fault detection CT s for Easergy 200E O Provision for EFPI O O Test facility Integral cable test facility b b Standard features Operating handle b b Transformer earth switch 3.15 ka 3 seconds b b Cable (see available cable kit accessories) Bottom entry up 300 mm 2 1 x 3C b b Bottom entry up 630 mm 2 3 x 1C b b Key: b Standard feature O Optional feature AMTED399086EN.indd 41
44 Circuit breaker, metering and switches Non-extensible switches 630 A Accessories SN6-S1 SN6-S2 Kit no. Cable kits Tee-off cable box v v RMR-F47 Gland plate 1 x 3C O O RMR-A48 Gland plate 3 x 1C O O RMR-A49 Angled gland plates (RMR) O O RMR-A50 Blank aluminium gland plate O O RMR-A52 Brass wiping gland 1 x 3C O O RMR-A10 Brass wiping gland 3 x 1C O O RMR-A11 Tubular gland 1 x 3C O O RMR-A12 Tubular gland 3 x 1C O O RMR-A13 CES5 gland plate 1 x 3C O O RMR-A132 Installation items Set of padlocks - 6 no O O RMR-A18/6 Anti-vandal fi xings, including tool O O RMR-A19 Foundation bolts (not required for transformer mounting) O O RMR-A22 Multicore pilot glands O O RMR-A16 Operational items Operating handle b b RMR-A23 VPIS indication ( kv) v v RMR-F108 Neon lamp test unit (including lamp) O O RMR-A24 Neon lamp O O RMR-A81 Actuator 24 V DC v RMR-F67 Mechanical interlocks Key free, earth on v RMR-F85 Key free, unit off v RMR-F86 Transformer earth switch, key free, earth on v v RMR-F110 N. B. specify lock symbol at time of ordering (3 digits max) not available with motor mechanisms Order codes 13.8 kv, 21 ka, 95 kvbil, 0.35bG SN6-S1/21 SN6-S2/21 General arrangement drawing - transformer mounted RMINST-04 Page 93 RMINST-04 Page 93 General arrangement drawing - freestanding RMINST-09 Page 145 RMINST-09 Page 145 Schematic diagram N/A RMSCH-28 Page 137 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site 42 AMTED399086EN.indd
45 Circuit breaker, metering and switches Non-extensible switch 630 A SN6-S1 DE60193 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cable box ref: RMINST-09 Schematic drawing ref: N/A Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 95 kv Operating mechanism Independent manual Standard features Transformer earth switch, 3.15 ka 3 s Cable earth switch, 21 ka 3 s Anti-refl ex operating handle Indication Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Test facility Integral cable test facilities Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Tee-off cable box VPIS indication Glands and plates Interlocks See page 42 for details Order information Code SN6-S1/21 Rating 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 43
46 Circuit breaker, metering and switches Non-extensible switch 630 A SN6-S2 DE60194 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-04 Installation drawing for freestanding unit with tee-off cable box ref: RMINST-09 Schematic drawing ref: RMSCH-28 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 95 kv Operating mechanism Independent manual Provision for actuator, 24 V DC Standard features Transformer earth switch, 3.15 ka 3 s Cable earth switch, 21 ka 3 s Anti-refl ex operating handle Indication Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Auxiliary contacts 1NO 2NC Earth selected auxiliary contact 1NO Test facility Integral cable test facilities Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Tee-off cable box Actuator, 24 V DC VPIS indication Glands and plates See page 42 for details Order information Code SN6-S2/21 Rating 21 ka, 13.8 kv, 95 kv BIL 44 AMTED399086EN.indd
47 Circuit breaker, metering and switches Non-extensible metering unit 200 A Specification MU2-M1 MU2-M2 MU2-M3 Environment Indoor / outdoor b b b IP54 b b b Ratings Normal rated current 200 A b b b 12 kv 16 ka 1 second 75 kv BIL b b b Metering (1) CT s -50/25/5 A 0.5s 7.5 VA b CT s -100/50/5 A 0.5s 10 VA b CT s -200/100/5 A 0.5s 10 VA b VT s -11 kv/110 V VA b b b Cable (see available cable kit accessories) Bottom entry up 300 mm 2 1 x 3C O O O Bottom entry up 630 mm 2 3 x 1C O O O Key: b Standard feature O Optional feature (1) CT s - 2 phases (R & B), VT s phase to phase. 6.6 kv VT s are available - Contact Schneider Electric AMTED399086EN.indd 45
48 Circuit breaker, metering and switches Non-extensible metering unit 200 A Accessories MU2-M1 MU2-M2 MU2-M3 Kit no. Cable kits Tee-off cable box v v v RMR-F47 Gland plate 1 x 3C O O O RMR-A48 Gland plate 3 x 1C O O O RMR-A49 Angled gland plates (RMU) O O O RMR-A51 Blank Blank aluminium gland plate O O O RMR-A52 Brass wiping gland 1 x 3C O O O RMR-A10 Brass wiping gland 3 x 1C O O O RMR-A11 Tubular gland 1 x 3C O O O RMR-A12 Tubular gland 3 x 1C O O O RMR-A13 CES5 gland plate 1 x 3C O O O RMR-A132 Installation items Set of padlocks - XX no O O O RMR-A18/6 Foundation bolts (not required for transformer mounting) O O O RMR-A22 Multicore pilot glands O O O RMR-A16 RMU - MU2 installation kit O O O RMR-A350 Freestanding installation kit O O O RMR-A90 Order codes 12 kv, 16 ka, 75 kv BIL, 0.35bG MU2-M1/16 MU2-M2/16 MU2-M3/16 General arrangement drawing - transformer mounted RMINST-07/08 Pages RMINST-07/08 Pages RMINST-07/08 Pages Schematic diagram RMSCH-14 Page 113 RMSCH-14 Page 113 RMSCH-14 Page 113 Key: v Factory fi tted accessory O Loose accessory, assembled on site 46 AMTED399086EN.indd
49 Circuit breaker, metering and switches Non-extensible metering unit 200 A MU2-M1 DE60210 Non-extensible metering unit Protection & control - CB N/A Metering transformers b Metering CT s R & B phases v 50/25/5 A v 7.5 VA class 0.5s b Metering VT ph - ph v 11 kv/110 V 50 VA v class 0.5 Documents Installation drawing ref: RMINST-07/08 Schematic drawing ref: RMSCH-14 Environment Indoor/outdoor IP54 Ratings Short time withstand 16 ka 1 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12 kv Normal rated BIL 75 kv Standard features Direct coupling between RMU and transformer (optional freestanding cable connection) Cable connection Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Cable box Glands and plates Installation kits See page 46 for details Order information Code MU2-M1/16 Rating 16 ka, 12 kv, 75 kv BIL AMTED399086EN.indd 47
50 Circuit breaker, metering and switches Non-extensible metering unit 200 A MU2-M2 DE60210 Non-extensible metering unit Protection & control - CB N/A Metering transformers b Metering CT s R & B phases v 100/50/5 A v 10 VA class 0.5s b Metering VT ph - ph v 11 kv/110 V 50 VA v class 0.5 Documents Installation drawing ref: RMINST-07/08 Schematic drawing ref: RMSCH-14 Environment Indoor/outdoor IP54 Ratings Short time withstand 16 ka 1 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12 kv Normal rated BIL 75 kv Standard features Direct coupling between RMU and transformer (optional freestanding cable connection) Cable connection Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Cable box Glands and plates Installation kits See page 46 for details Order information Code MU2-M2/16 Rating 16 ka, 12 kv, 75 kv BIL 48 AMTED399086EN.indd
51 Circuit breaker, metering and switches Non-extensible metering unit 200 A MU2-M3 DE60210 Non-extensible metering unit Protection & control - CB N/A Metering transformers b Metering CT s R & B phases v 200/100/5 A v 10 VA class 0.5s b Metering VT ph - ph v 11 kv/110 V 50 VA v class 0.5 Documents Installation drawing ref: RMINST-07/08 Schematic drawing ref: RMSCH-14 Environment Indoor/outdoor IP54 Ratings Short time withstand 16 ka 1 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12 kv Normal rated BIL 75 kv Standard features Direct coupling between RMU and transformer (optional freestanding cable connection) Cable connection Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Cable box Glands and plates Installation kits See page 46 for details Order information Code MU2-M3/16 Rating 16 ka, 12 kv, 75 kv BIL AMTED399086EN.indd 49
52 Circuit breaker, metering and switches Non-extensible metering units 630 A Specification MU6-N1 MU6-N2 MU6-N3 MU6-N5 Environment Indoor / outdoor b b b b IP54 b b b b Ratings Normal rated current 630 A b b b b 12 kv 16 ka 1 second 75 kv BIL b b b b Metering (1) CT s - 400/600/5 A 10 VA b CT s - 600/5 A 10 VA b CT s - 400/5 A 10 VA b CT s - 600/300/5 A 10 VA b VT s - 11 kv/110 V VA b b b VT s - 11 kv/6.6 kv/110 V VA b Cable (see available cable kit accessories) Bottom entry up 300 mm 2 1 x 3C O O O O Bottom entry up 630 mm 2 3 x 1C O O O O Key: b Standard feature O Optional feature (1) CT s - 2 phases (R&B), VT s phase to phase 6.6 kv VT s are available - Contact Schneider Electric 50 AMTED399086EN.indd
53 Circuit breaker, metering and switches Non-extensible metering units 630 A Accessories MU6-N1 MU6-N2 MU6-N3 MU6-N5 Kit no. Cable kits Tee-off cable box v v v v RMR-F47 Gland plate 1 x 3C O O O O RMR-A48 Gland plate 3 x 1C O O O O RMR-A49 Angled gland plates (RMU) O O O O RMR-A51 Blank Blank aluminium gland plate O O O O RMR-A52 Brass wiping gland 1 x 3C O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O RMR-A11 Tubular gland 1 x 3C O O O O RMR-A12 Tubular gland 3 x 1C O O O O RMR-A13 CES5 gland plate 1 x 3C O O O O RMR-A132 Installation items Set of padlocks - XX no O O O O RMR-A18/6 Foundation bolts (not required for transformer mounting) O O O O RMR-A22 Multicore pilot glands O O O O RMR-A16 RMU - MU6 installation kit O O O O RMR-A350 Freestanding installation kit O O O O RMR-A90 Order codes 12 kv, 16 ka, 75 kvbil, 0.35bG MU6-N1/16 MU6-N2/16 MU6-N3/16 MU6-N5/16 General arrangement drawing - transformer mounted RMINST-07/08 Pages RMINST-07/08 Pages RMINST-07/08 Pages RMINST-07/08 Pages Schematic diagram RMSCH-14 Page 113 RMSCH-14 Page 113 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site RMSCH-14 Page 113 RMSCH-14 Page 113 AMTED399086EN.indd 51
54 Circuit breaker, metering and switches Non-extensible metering units 630 A MU6-N** DE60210 Non-extensible metering unit Protection & control - CB N/A Metering transformers b Metering CT s R & B phases (16 ka, 12 kv, 75 kv BIL) 10 VA class 0.5s N1/16 N2/16 N3/16 N5/16 400/200/5 A b 600/5 A b 400/5 A b 600/300/5 A b b Metering VT ph - ph (16 ka, 12 kv, 75 kv BIL) 50 VA class 0.5 N1/16 N2/16 N3/16 N5/16 11 kv/110 V b b b 11 kv/6.6 kv/110 V b Documents Installation drawing ref: RMINST-07/08 Schematic drawing ref: RMSCH-14 Environment Indoor/outdoor IP54 Ratings Short time withstand 16 ka 1 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 12 kv Normal rated BIL 75 kv Standard features Direct coupling between RMU and transformer (optional freestanding cable connection) Cable connection Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Cable box Glands and plates Installation kits See page 51 for details Order information Code MU6-N** Rating 16 ka, 12 kv, 75 kv BIL 52 AMTED399086EN.indd
55 Circuit breaker, metering and switches Extensible circuit breakers 200 A Specification CE2- T2 CE2- T3 Environment Indoor / outdoor b b b b b b b b b b b b b IP54 b b b b b b b b b b b b b Ratings Busbars 630 A b b b b b b b b b b b b b Circuit breaker normal rated current 200 A b b b b b b b b b b b b b 12 kv 16 ka 3 seconds 75 kv BIL b b b b b b b b b b b b b 13.8 kv 21 ka 3 seconds 95 kv BIL O O O O O O O O O O O O O Cable earth switch 16 ka 3 seconds b b b b b b b b b b b b b Cable earth switch 21 ka 3 seconds O O O O O O O O O O O O O Mechanism Independent manual b b b b b b b b b b b b b Provision for actuator 24 V DC b b b b Actuator 24 V DC O O O O Operating handle b b b b b b b b b b b b b Protection system CT s dual ratio - 500/200/1 A class x b b Overcurrent relay - VIP 30 b CT s dual ratio - 100/50/5 A class X b CT s dual ratio 200/100/1 A 5P20 b CT ratio - 200/1 A class X b b b b b b b b b Overcurrent & earth fault CT operated trip coils b Overcurrent & earth fault relay VIP 35 b Time fuse link O IDMT overcurrent & earth fault relay - VIP 300 b b b b b b b b b IDMT overcurrent and earth fault relay Sepam 10 b 20 V-250 shunt trip coil b b b b b b b b b b b b b Auxiliary switch 1NO 2NC b b b b b b b b b b b b b Metering CT s -200/100/5 A 0.5s 10 VA b b b b b b b VT s kv/110 V VA 13.8/110 V/110 V VA 3P 20 VA b b VT s -11 kv/110 V VA b b b VT s -6.6 kv/110 V VA b b VT s phase - phase, CT s R & B b b b b VT s phase - earth, CT s RYB b b b Indication Mechanical ON/OFF b b b b b b b b b b b b b Mechanical EARTH/MAIN b b b b b b b b b b b b b Cable VPIS indication ( kv) O O O O O O O O O O O O O Auxiliary switch contacts 1NO 2NC b b b b b b b b b b b b b Earth selected auxiliary contacts 1NO b b b b Test facility Integral cable test facility b b b b b b b b b b b b b Cable Bottom entry up to 300 mm 2 1 x 3C b b b b b b b b b b b b b Bottom entry up to 630 mm 2 3 x 1C b b b b b b b b b b b b b Top entry cables O O O O O O O O O O O O O Key: b Standard feature O Optional feature CE2- T7 CE2- T11 CE2- T12 CE2- T13 CE2- T14 CE2- T15 CE2- T16 CE2- T19 CE2- T20 CE2- T21 CE2- T25 AMTED399086EN.indd 53
56 Circuit breaker, metering and switches Extensible circuit breakers 200 A Accessories CE2- T2 CE2- T3 CE2- T7 CE2- T11 CE2- T12 CE2- T13 Cable kits Gland plate 1 x 3C O O O O O O O O O O O O O RMR-A48 Gland plate 3 x 1C O O O O O O O O O O O O O RMR-A49 Angled gland plates (RMR) O O O O O O O O O O O O O RMR-A50 Blank aluminium gland plate O O O O O O O O O O O O O RMR-A52 Brass wiping gland 1 x 3C O O O O O O O O O O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O O O O O O O O O O RMR-A11 Tubular gland 1 x 3C O O O O O O O O O O O O O RMR-A12 Tubular gland 3 x 1C O O O O O O O O O O O O O RMR-A13 CES5 gland plate 1 x 3C O O O O O O O O O O O O O RMR-A132 Top entry cables standard panels v v v v v v RMR-F93 Top entry cables MU6 only v v v v v v v RMR-F94 Installation items 3 phase busbars 630 A O O O O O O RMR-A14 3 phase busbars 630 A O O O O O O O RMR-A78 Busbar end kit O O O O O O O O O O O O O RMR-A15 Set of padlocks - 6 no O O O O O O O O O O O O O RMR-A18/6 Foundation bolts (not required b b b b b b b b b b b b b RMR-A22 for transformer mounting) Multicore pilot glands O O O O O O O O O O O O O RMR-A16 Time limit fuses (set of 2 - specify O RMR-A17 rating as table page 115) Operational items Operating handle b b b b b b b b b b b b b RMR-A23 Cable VPIS indication v v v v v v v v v v v v v RMR-F108 ( kv) Neon lamp test unit v v v v v v v v v v v v v RMR-A24 (including lamp) Neon lamp O O O O O O O O O O O O RMR-A81 VAP 6 test unit for VIP 300 O O O O O O O O O O O O RMR-A202 Actuator 24 V DC v v v RMR-F67 Polarity conversion kit (1) v v v RMR-F391 Mechanical interlocks Key free, EARTH ON v v v v v v v RMR-F85 Key free, MAIN OFF v v v v v v v RMR-F86 N. B. specify lock symbol at time of ordering (3 digits max) not available with motor mechanisms Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site (1) Only required when unit is used with RE2c ring main units and automation. CE2- T14 CE2- T15 CE2- T16 CE2- T19 CE2- T20 CE2- T21 CE2- T25 Kit no. 54 AMTED399086EN.indd
57 Circuit breaker, metering and switches Extensible circuit breakers 200 A Accessories CE2- T2 CE2- T3 CE2- T7 CE2- T11 CE2- T12 CE2- T13 Earth fault passage indication (choose provision kit and an EFPI required if not using Easergy 200E) EFPI provision kit, inside O O O O O O O O O O O O O RMR-F30 cable box Bowden STD EFPI type NB O O O O O O O O O O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O O O O O O O O O O RMR-A278 Bowden LV reset & alarm O O O O O O O O O O O O O RMR-A279 type NB2 Bowden RR EFPI and CT O O O O O O O O O O O O O RMR-A56 Fundamentals ER FIND O O O O O O O O O O O O O RMR-A57 EFPI and CT Ancillary items Tool box O O O O O O O O O O O O O RMR-A80 Order code 12 kv, 16 ka, 75 kv BIL, 0.35bG CE2- T2/ kv, 21 ka, 95 kv BIL, 0.55bG CE2- T2/21 CE2- T3/16 CE2- T3/21 CE2- T7/16 CE2- T7/21 CE2- T11/16 CE2- T11/21 CE2- T12/16 CE2- T12/21 CE2- T13/16 CE2- T13/21 CE2- T14 CE2- T14/16 CE2- T14/21 CE2- T15 CE2- T15/16 CE2- T15/21 CE2- T16 CE2- T16/16 CE2- T16/21 CE2- T19 N/A CE2- T19/21 CE2- T20 CE2- T20/16 N/A CE2- T21 N/A CE2- T21/21 CE2- T25 N/A CE2- T25/21 General arrangement drawing RMINST-03 RMINST-02 RMINST-03 RMINST-02 RMINST-03 RMINST-02 RMINST-02 RMINST-03 RMINST-03 RMINST-02 RMINST-02 RMINST-02 RMINST-03 Page 92 Page 91 Page 92 Page 91 Page 92 Page 91 Page 91 Page 92 Page 92 Page 91 Page 91 Page 91 Page 92 Schematic drawing RMSCH-07 RMSCH-09 RMSCH-06 RMSCH-09 RMSCH-19 RMSCH-20 RMSCH-20 RMSCH-07 RMSCH-07 RMSCH-35 RMSCH-35 RMSCH-36 RMSCH-47 to 50 Page 121 Page 123 Page 120 Page 123 Page 127 Page 128 Page 128 Page 121 Page 121 Page 133 Page 133 Page 134 Pages 114 to 117 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site Kit no. AMTED399086EN.indd 55
58 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T2 DE60251 Feeder protection up to 3.5 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 200/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-07 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Test facility Integral cable test facilities Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order information Code CE2-T2/16 CE2-T2/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 56 AMTED399086EN.indd
59 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T7 DE60196 Transformer protection up to 1.5 MVA at 11 kv Protection & control - CB Overcurrent and earth fault protection using CT operated trip coils with provision for time fuse links. Protection CT s - 100/50/5 A class X Shunt trip coil, 20 V DC-250 V AC Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-06 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order information Code CE2-T7/16 CE2-T7/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 57
60 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T* DE60252 (Select VT rating and switchgear rating from table below). Feeder protection up to 3.5 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 200/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Metering transformers b Metering CT s R & B phases v 200/100/5 A v 10 VA class 0.5s b Metering VT v see below Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Anti-reflex operating handle Standard features Cable earth switch, 16/21 ka 3 s Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order code 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL Metering VT information: Phase to phase CE2-T3/16 CE2-T3/21 b CE2-T11/16 CE2-T11/21 b N/A CE2-T19/21 Phase to earth b b 6.6 kv/110 V b 11 kv/110 V (1) b b 13.8 kv/110 V b General arrangement drawing Schematic diagram RMINST-02 Page 91 RMSCH-09 Page 123 RMINST-02 Page 91 RMSCH-09 Page 123 RMINST-02 Page 91 RMSCH-35 Page 133 (1) Please consult Schneider Electric when ordering units with 95 kv BIL voltage Tel: +44 (0) CE2-T20/16 N/A RMINST-02 Page 91 RMSCH-35 Page AMTED399086EN.indd
61 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T12 DE60253 Feeder protection up to 3.5 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 200/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-19 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Provision for actuator, 24 V DC Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contact1no Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Actuator, 24 V DC VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order information Code CE2-T12/16 CE2-T12/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 59
62 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T** DE60254 (Select VT rating and switchgear rating from table below). Feeder protection up to 3.5 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 200/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Metering transformers b Metering CT s v 200/100/5 A v 10 VA class 0.5s b Metering VT v see below Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Provision for actuator, 24 V DC Standard features Cable earth switch, 16/21 ka 3 s Anti-reflex operating handle Indication Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Earth selected auxiliary contact1no Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Actuator, 24 V DC VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order code 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL Metering VT information: Phase to phase Phase to earth CE2-T14/16 CE2-T14/21 b 6.6 kv/110 V b 11 kv/110 V (1) 13.8 kv/110 V b General arrangement drawing Schematic diagram RMINST-02 Page 91 RMSCH-20 Page 128 N/A CE2-T21/21 b RMINST-02 Page 91 RMSCH-36 Page 134 (1) Please consult Schneider Electric when ordering units with 95 kv BIL voltage Tel: +44 (0) AMTED399086EN.indd
63 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T13 DE60254 Feeder protection up to 3.5 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 200/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Metering transformers b Metering CT s v 200/100/5 A v 10 VA class 0.5s b Metering VT ph - ph v 11 kv/110 V 50 VA v class 0.5 Documents Installation drawing ref: RMINST-02 Schematic drawing ref: RMSCH-20 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Actuator, 24 V DC Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Earth selected auxiliary contact1no Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order information Code CE2-T13/16 CE2-T13/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 61
64 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T15 DE60251 Feeder protection up to 2.5 MVA at 11 kv Protection & control - CB Self powered overcurrent relay, VIP 30. Protection CT s - 500/200/1 A class X b Setting range: 500/1 A v Overcurrent: A b Setting range: 200/1 A v Overcurrent: 8-80 A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-12 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Test facility Integral cable test facilities Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order information Code CE2-T15/16 CE2-T15/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 62 AMTED399086EN.indd
65 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T16 DE60255 Feeder protection up to 2.5 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 35. Protection CT s - 500/200/1 A class X CH30 core balance CT b Setting range: 500/1 A v Overcurrent: A v Earth fault: A b Setting range: 200/1 A v Overcurrent: 8-80 A v Earth fault: A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-13 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Gas pressure indicator Test facility Integral cable test facilities Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Operating handle Busbar kit Top entry cables See page 54 for details Order information Code CE2-T16/16 CE2-T16/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 63
66 Circuit breaker, metering and switches Extensible circuit breaker 200 A CE2-T25 DE59803 Sepam 10 functions Protection Earth-fault protection 50/51 50N/51N 49RMS ANSI code CE2-T25 (1) B BS A AS Standard 50N/51N b b In (2) Sensitive 50G/51G b b A Phase-overcurrent protection 50/51 b b b b In (2) Thermal overload protection 49RMS b b b b Phase-overcurrent and b b b b earth-fault cold load pick-up Logic Blocking send 68 b b b b discrimination Blocking reception b b External tripping via digital input b b Measurement Earth-fault current b b b b Phase currents b b b b Peak demand currents b b b b Control and supervision Circuit breaker tripping 86 b b b b and lockout Tripping annunciation 30 b b b b Tripped on fault, volt free contact b b b b Relay watchdog contact b b Remote CB position monitoring b b Record of last fault b b b b Record of last fi ve events b b Communications Modbus b b IEC b b (1) B (basic), BS (basic + sensitive earth-fault), A (advanced), AS (advanced + sensitive earth-fault) (2) In = Primary CT ratio (3) Only with T25B and T25BS. Transformer protection up to 3.5 MVA at 11 kv Protection & control - CB IDMT overcurrent, earth-fault and thermal overload relay, Sepam series 10. In accordance with IEC Power supply VDC required Protection CT s - 200/100/1 A 5P20 Setting range (200/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Setting range (100/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Documents (1) Schematic drawing ref: CE2 T25B: RMSCH-47 CE2 T25BS: RMSCH-48 CE2 T25A: RMSCH-49 CE2 T25AS: RMSCH-50 Environment Indoor/outdoor IP54 Ratings Busbar 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 200 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-reflex operating handle Indication Mechanical tripped on fault fl ag indication Mechanical ON/OFF indication Mechanical earth/main indication Gas pressure indication CB auxiliary contacts 1NO 1NC (3) Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm² Bottom entry up to 3 x 1C 630 mm² Accessories - see table, page 54 Tee-off cable box Glands and plates Interlocks Order information Code (1) CE2-T25B/21 CE2-T25BS/21 CE2-T25A/21 CE2-T25AS/21 Rating 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 64 AMTED399086EN.indd
67 Circuit breaker, metering and switches Extensible circuit breakers 630 A Specification CE6- T4 CE6- T5 Environment Indoor / outdoor b b b b b b b b b b IP54 b b b b b b b b b b Ratings Busbars 630 A b b b b b b b b b b Circuit breaker normal rated current 630 A b b b b b b b b b b 12 kv 16 ka 3 seconds 75 kv BIL b b b b b b b b b b 13.8 kv 21 ka 3 seconds 95 kv BIL O O O O O O O O O O Cable earth switch 16 ka 3 seconds b b b b b b b b b b Cable earth switch 21 ka 3 seconds O O O O O O O O O O Mechanism Independent manual b b b b b b b b b b Provision for actuator 24 V DC b b b b Actuator 24 V DC O O O O Operating handle b b b b b b b b b b Protection system CT ratio - 800/1 A class X b b b b b b b b b CT dual ratio 800/400/1 A 5P20 b IDMT overcurrent & earth fault relay - VIP 300 b b b b b b b b b IDMT overcurrent & earth fault relay Sepam 10 b 20 V-250 V shunt trip coil b b b b b b b b b b Auxiliary switch 1NO 2NC b b b b b b b b b b Metering CT s - 400/200/5 A 0.5s 10 VA b b b b b b b VT s kv/110 V/110 V/ VA 3P 20 VA b b VT s - 11 V/110 V VA b b b VT s kv/110 V VA b b VT s - phase - phase, CT s R & B b b b b VT s phase - earth, CT s RYB b b b Indication Mechanical ON/OFF b b b b b b b b b b Mechanical EARTH/MAIN b b b b b b b b b b Cable VPIS indication ( kv) O O O O O O O O O O Auxiliary switch contacts 1NO 2NC b b b b b b b b b b Indication CT 600/5 A 5 VA CLS 1 Yph b b b b b b b b b Ammeter A b b b b b b b b b Earth selected auxiliary contacts 1NO b b b Gas pressure indicator b b b b b b b b b b Test facility Integral cable test facility b b b b b b b b b b Cable Bottom entry up to 300 mm 2 1 x 3C b b b b b b b b b b Bottom entry up to 630 mm 2 3 x 1C b b b b b b b b b b Top entry cables O O O O O O O O O O Key: b Standard feature O Optional feature CE6- T6 CE6- T8 CE6- T9 CE6- T10 CE6- T22 CE6- T23 CE6- T24 CE6- T25 AMTED399086EN.indd 65
68 Circuit breaker, metering and switches Extensible circuit breakers 630 A Accessories CE6- T4 CE6- T5 CE6- T6 CE6- T8 Cable kits Gland plate 1 x 3C O O O O O O O O O O RMR-A48 Gland plate 3 x 1C O O O O O O O O O O RMR-A49 Angled gland plates (RMR) O O O O O O O O O O RMR-A50 Blank aluminium gland plate O O O O O O O O O O RMR-A52 Brass wiping gland 1 x 3C O O O O O O O O O O RMR-A10 Brass wiping gland 3 x 1C O O O O O O O O O O RMR-A11 Tubular gland 1 x 3C O O O O O O O O O O RMR-A12 Tubular gland 3 x 1C O O O O O O O O O O RMR-A13 CES5 gland plate 1 x 3C O O O O O O O O O O RMR-A132 Top entry cables standard panels v v v RMR-F93 Top entry cables MU6 only v v v v v v v RMR-F94 Installation items 3 phase busbars 630 A O O O RMR-A14 3 phase busbars 630 A O O O O O O O RMR-A78 Busbar end kit O O O O O O O O O O RMR-A15 Set of padlocks - 6 no O O O O O O O O O O RMR-A18/6 Foundation bolts (not required for b b b b b b b b b b RMR-A22 transformer mounting) Multicore pilot glands O O O O O O O O O O RMR-A16 Operational items Operating handle b b b b b b b b b b RMR-A23 Cable VPIS indication ( kv) v v v v v v v v v v RMR-A108 Neon lamp test unit (including lamp) O O O O O O O O O O RMR-A24 Neon lamp O O O O O O O O O O RMR-A81 VAP 6 test unit for VIP 300 O O O O O O O O RMR-A202 Actuator 24 V DC v v v v RMR-F67 Polarity conversion kit (1) v v v v RMR-F391 Mechanical interlocks Key free, EARTH ON v v v v v v RMR-F85 Key free, MAIN OFF v v v v v v RMR-F86 N. B. specify lock symbol at time of ordering ( 3 digits max) not available with motor mechanisms Earth fault passage indication (choose provision kit and an EFPI required if not using Easergy T200E) EFPI provision kit, inside cable box O O O O O O O O O O RMR-F30 Bowden STD EFPI type NB O O O O O O O O O O RMR-A277 Bowden LV reset EFPI type NB1 O O O O O O O O O O RMR-A278 Bowden LV reset & alarm type NB2 O O O O O O O O O O RMR-A279 Bowden RR EFPI and CT O O O O O O O O O O RMR-A56 Fundamentals ER FIND EFPI and CT O O O O O O O O O O RMR-A57 Ancillary items Tool box O O O O O O O O O O RMR-A80 Order code 12 kv, 16 ka, 75 kv BIL, 0.35bG CE6- T4/ kv, 21 ka, 95 kv BIL, 0.55bG CE6- T4/21 General arrangement drawing Schematic drawing RMINST-03 Page 92 RMSCH-08 Page 122 CE6- T5/16 CE6- T5/21 CE6- T6/16 CE6- T6/21 CE6- T8/16 CE6- T8/21 CE6- T9 CE6- T9/16 CE6- T9/21 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site (1) Only required when unit is used with RE2c ring main units and automation. CE6- T10 CE6- T10/16 CE6- T10/21 CE6- T22 CE6- T23 CE6- T24 N/A N/A CE6- T24/16 CE6- T25 CE6- T22/21 CE6- T23/21 N/A CE6- T25/21 RMINST-02 RMINST-02 RMINST-03 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-03 Page 91 Page 91 Page 92 Page 91 Page 91 Page 91 Page 91 Page 91 Page 92 RMSCH-10 RMSCH-10 RMSCH-23 RMSCH-24 RMSCH-24 RMSCH-37 RMSCH-38 RMSCH-37 RMSCH-47 to 50 Page 124 Page 124 Page 131 Page 132 Page 132 Page 135 Page 136 Page 135 Pages 114 to 117 Kit no. 66 AMTED399086EN.indd
69 Circuit breaker, metering and switches Extensible circuit breaker 630 A CE6-T4 DE60256 Feeder protection up to 12 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 800/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-08 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Ammeter A Indication CT Y ph - 600/5 A class 1.0, 5 VA Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Busbar kit Top entry cables See page 66 for details Order information Code CE6-T4/16 CE6-T4/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 67
70 Circuit breaker, metering and switches Extensible circuit breaker 630 A CE6-T* DE60197 (Select VT rating and switchgear rating from table below). Feeder protection up to 12 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 800/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Metering transformers b Metering CT s v 400/200/5 A v 10 VA class 0.5s b Metering VT v see below Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-reflex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Ammeter A Indication CT Y ph - 600/5 A class 1.0, 5 VA Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Actuator, 24 V DC VPIS indication Glands and plates Interlocks Busbar kit Top entry cables See page 66 for details Order code 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL Metering VT information: Phase to phase CE6-T5/16 CE6-T5/21 b CE6-T6/16 CE6-T6/21 b N/A CE6-T22/21 Phase to earth b b 6.6 kv/110 V b 11 kv/110 V (1) b b 13.8 kv/110 V b General arrangement drawing Schematic diagram RMINST-02 Page 91 RMSCH-10 Page 124 RMINST-02 Page 91 RMSCH-10 Page 124 RMINST-02 Page 91 RMSCH-37 Page 135 (1) Please consult Schneider Electric when ordering units with 95 kv BIL voltage Tel: +44 (0) CE6-T24/16 N/A RMINST-02 Page 91 RMSCH-37 Page AMTED399086EN.indd
71 Circuit breaker, metering and switches Extensible circuit breaker 630 A CE6-T8 DE60257 Feeder protection up to 12 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 800/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-23 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Provision for actuator, 24 V DC Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contact1no Ammeter A Indication CT Y ph - 600/5 A class 1.0, 5 VA Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Actuator, 24 V DC VPIS indication Glands and plates Interlocks Busbar kit Top entry cables See page 66 for details Order information Code CE6-T8/16 CE6-T8/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 69
72 Circuit breaker, metering and switches Extensible circuit breaker 630 A CE6-T25 DE59803 Sepam 10 functions Protection Earth-fault protection 50/51 50N/51N 49RMS ANSI code CE6-T25 (1) B BS A AS Standard 50N/51N b b In (2) Sensitive 50G/51G b b A Phase-overcurrent protection 50/51 b b b b In (2) Thermal overload protection 49RMS b b b b Phase-overcurrent and b b b b earth-fault cold load pick-up Logic Blocking send 68 b b b b discrimination Blocking reception b b External tripping via digital input b b Measurement Earth-fault current b b b b Phase currents b b b b Peak demand currents b b b b Control and supervision Circuit breaker tripping 86 b b b b and lockout Tripping annunciation 30 b b b b Tripped on fault, volt free contact b b b b Relay watchdog contact b b Remote CB position monitoring b b Record of last fault b b b b Record of last fi ve events b b Communications Modbus b b IEC b b (1) B (basic), BS (basic + sensitive earth-fault), A (advanced), AS (advanced + sensitive earth-fault) (2) In = Primary CT ratio (3) Only with T25B and T25BS. Feeder protection up to 12 MVA at 11 kv Protection & control - CB IDMT overcurrent, earth-fault and thermal overload relay, Sepam series 10. In accordance with IEC Power supply VDC required Protection CT s - 800/400/1 A 5P20 Setting range (800/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Setting range (400/1): overcurrent: A, earth-fault: A, sensitive earth-fault: A Documents (1) Schematic drawing ref: CE6 T25B: RMSCH-47 CE6 T25BS: RMSCH-48 CE6 T25A: RMSCH-49 CE6 T25AS: RMSCH-50 Environment Indoor/outdoor IP54 Ratings Busbar 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-reflex operating handle Indication Mechanical tripped on fault fl ag indication Mechanical ON/OFF indication Mechanical earth/main indication Gas pressure indication CB auxiliary contacts 1NO 1NC (3) Test facility Integral ring switch cable test facility Cable Bottom entry up to 1 x 3C 300 mm² Bottom entry up to 3 x 1C 630 mm² Accessories - see table, page 66 Tee-off cable box Glands and plates Interlocks Order information Code (1) CE6-T25B/21 CE6-T25BS/21 CE6-T25A/21 CE6-T25AS/21 Rating 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 21 ka, 13.8 kv, 95 kv BIL 70 AMTED399086EN.indd
73 Circuit breaker, metering and switches Extensible circuit breaker 630 A CE6-T** DE60199 (Select VT rating and switchgear rating from table below). Feeder protection up to 12 MVA at 11 kv Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 800/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Metering transformers b Metering CT s v 400/200/5 A v 10 VA class 0.5s b Metering VT v see below Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 12/13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features Cable earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contacts Ammeter A Indication CT Y ph- 600/5 A class 1.0, 5 VA Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Busbar kit Top entry cables See page 66 for details Order code 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL Metering VT information: Phase to phase Phase to earth CE6-T9/16 CE6-T9/21 b CE6-T10/16 CE6-T10/21 b 6.6 kv/110 V b 11 kv/110 V (1) b 13.8 kv/110 V b General arrangement drawing Schematic diagram RMINST-02 Page 91 RMSCH-24 Page 132 RMINST-02 Page 91 RMSCH-24 Page 132 (1) Please consult Schneider Electric when ordering units with 95 kv BIL voltage Tel: +44 (0) N/A CE6-T23/21 b RMINST-02 Page 91 RMSCH-38 Page 136 AMTED399086EN.indd 71
74 Circuit breaker, metering and switches Extensible switches 630 A Specification SE6-S1 SE6-S2 SE6-E1 Environment Indoor / outdoor b b b IP54 b b b Ratings Busbars 630 A b b b Switch normal rated current 630 A b b b 13.8 kv 21 ka 3 seconds 95 kv BIL b b b Cable earth switch 21 ka 3 seconds b b Mechanism Independent manual b b b Provision for actuator 24 V DC b Actuator 24 V DC O Operating handle b b b Indication Mechanical ON/OFF b b Mechanical EARTH/MAIN b b b Cable VPIS indication ( kv) v v Busbar VPIS indication ( kv) v v Auxiliary switch contacts1no 1 NC v Phase and earth fault detection CT s for Easergy T200E O EFPI provision only CT inside box O O b Gas pressure indicator b b b Test facility Integral cable test facility b b Integral test facility RH/LH busbar earthing b Cable (see available cable kit accessories) Bottom entry up to 300 mm 2 1 x 3C b b Bottom entry up to 630 mm 2 3 x 1C b b Top entry cables O O Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site 72 AMTED399086EN.indd
75 Circuit breaker, metering and switches Extensible switches 630 A Accessories SE6-S1 SE6-S2 SE6-E1 Kit no. Cable kits Gland plate 1 x 3C O O RMR-A48 Gland plate 3 x 1C O O RMR-A49 Angled gland plates (RMR) O O RMR-A50 Blank aluminium gland plate O O RMR-A52 Brass wiping gland 1 x 3C O O RMR-A10 Brass wiping gland 3 x 1C O O RMR-A11 Tubular gland 1 x 3C O O RMR-A12 Tubular gland 3 x 1C O O RMR-A13 CES5 gland plate 1 x 3C O O RMR-A132 Top entry cables v v RMR-F93 Installation items 3 phase busbars 630 A O O v RMR-A14 Set of padlocks - 6 no O O O RMR-A18/6 Busbar end kit (1 end kit required per switchboard) O O O RMR-A15 Foundation bolts (not required for transformer mounting) b b b RMR-A22 Multicore pilot glands O RMR-A16 Operational items Operating handle b b b RMR-A23 Cable VPIS indication ( kv) v v RMR-F108 Cable and busbar VPIS indication ( kv) v v RMR-F92 Neon lamp test unit (including lamp) O O RMR-A24 Neon lamp O O RMR-A81 Actuator 24 V DC v RMR-F67 Polarity conversion kit (1) v RMR-F391 Mechanical interlocks Key free, earth ON v v RMR-F85 Key free, main OFF v RMR-F86 N. B. specify lock symbol at time of ordering ( 3 digits max) not available with motor mechanisms Indication EFPI provision kit, inside cable box O O RMR-F30 Bowden STD EFPI NB O O RMR-A277 Bowden LV reset EFPI type NB1 O O RMR-A278 Bowden LV reset & alarm type NB2 O O RMR-A279 Bowden RR EFPI and CT O O RMR-A56 Fundamentals ER FIND EFPI and CT O O RMR-A57 Ancillary items Tool box O O O RMR-A80 Order code 13.8 kv, 21 ka, 95 kv BIL, 0.55bG SE6-S1/21 SE6-S2/21 SE6-E1/21 General arrangement drawing RMINST-03 Page 92 RMINST-03 Page 92 RMINST-03 Page 92 Schematic drawing N/A RMSCH-29 N/A Page 138 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site (1) Only required when unit is used with RE2c ring main units and automation. AMTED399086EN.indd 73
76 Circuit breaker, metering and switches Extensible switch 630 A SE6-S1 DE60201 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-N/A Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 95 kv Operating mechanism Independent manual Standard features Cable earth switch, 21 ka 3 s Anti-refl ex operating handles Indication Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories VPIS indication Glands and plates Interlocks Busbar kit Top entry cables See page 73 for details Order information Code SE6-S1/21 Rating 21 ka, 13.8 kv, 95 kvbil 74 AMTED399086EN.indd
77 Circuit breaker, metering and switches Extensible switch 630 A SE6-S2 DE60202 Switch disconnector Protection & control - CB Non-automatic Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-29 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 95 kv Operating mechanism Independent manual Provision for actuator, 24 V DC Standard features Cable earth switch, 21 ka 3 s Anti-refl ex operating handle Indication Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2NC Earth selected auxiliary contact 1NO Gas pressure indicator Test facility Integral cable test facility Cable Bottom entry up to 300 mm 2 1 x 3C Bottom entry up to 630 mm 2 3 x 1C Accessories Actuator, 24 V DC VPIS indication Glands and plates Interlocks Busbar kit Top entry cables See page 73 for details Order information Code SE6-S2/21 Rating 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 75
78 Circuit breaker, metering and switches Extensible switch 630 A SE6-E1 DE60203 Busbar earthing switch Documents Installation drawing ref: RMINST-03 Schematic drawing ref: RMSCH-N/A Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 95 kv Operating mechanism Independent manual Standard features Cable earth switch, 21 ka 3 s Anti-refl ex operating handle Indication Mechanical earth/main indicator Gas pressure indicator Test facility N/A Cable N/A Accessories Interlocks Busbar kit See page 73 for details Order information Code SE6-E1/21 Rating 21 ka, 13.8 kv, 95 kv BIL 76 AMTED399086EN.indd
79 Circuit breaker, metering and switches Extensible bus-section 630 A Specification SE6-B1 CE6-B3 CE6-B5 Environment Indoor / outdoor b b b IP54 b b b Ratings Busbars 630 A b b b Circuit breaker normal rated current 630 A b b Switch normal rated current 630 A b 12 kv 16 ka 3 seconds 75 kv BIL b b 13.8 kv 21 ka 3 seconds 95 kv BIL b O O RH busbar earth switch 16 ka 3 seconds b b RH busbar earth switch 21 ka 3 seconds b O O Mechanism Independent manual b b b Provision for actuator 24 V DC b Actuator 24 V DC O Operating handle b b b Protection system CT ratio - 800/1 A class X b b IDMT overcurrent & earth fault relay - VIP 300 b b V shunt trip coil b b Auxiliary switch1no 2 NC b b Metering CT s - 400/200/5 A 0.5s 10 VA b b VT s - 11 ka/110 V VA b b VT s phase - phase, CT s R & B b b Indication Mechanical ON/OFF b b b Mechanical EARTH/MAIN b b b Earth selected auxiliary contact1no b RH busbar VPIS indication O O O Auxiliary switch contacts1no 2NC b b Indication CT 600/5 A 5 VA CLS 1 Y phase b b Ammeter A b b Gas pressure indicator b b b Integral test facility RH busbar earthing b b b LH busbar earthing ( using SE6-E1) O O O Key: b Standard feature O Optional feature AMTED399086EN.indd 77
80 Circuit breaker, metering and switches Extensible bus-section 630 A Accessories SE6-B1 CE6-B3 CE6-B5 Kit no. Installation items 3 phase busbars 630 A RMR-A14 3 phase busbars 630 A (Joggle metering) v v v RMR-A79 3 phase busbars 630 A double width (metering) v v v RMR-A78 Set of padlocks - XX no O O O RMR-A18/6 Busbar end kit (1 end kit required per switchboard) O O O RMR-A15 Foundation bolts (not required for transformer mounting) b b b RMR-A22 Multicore pilot glands O O RMR-A16 Operational items Operating handle b b b RMR-A23 LH and RH busbar VPIS indication v v v RMR-F92 Neon lamp test unit (including lamp) O O RMR-A24 Neon lamp O O O RMR-A81 VAP6 test unit for VIP 300 O O RMR-A202 Actuator 24 V DC v RMR-F67 Polarity conversion kit (1) v RMR-F391 Mechanical interlocks Key free, earth ON v v RMR-F85 Key free, main OFF v v RMR-F86 N. B. specify lock symbol at time of ordering ( 3 digits max) not available with motor mechanisms Ancillary items Tool box O O O RMR-A80 Order code 12 kv, 16 ka, 75 kv BIL, 0.35bG N/A CE6-B3/16 CE6-B5/ kv, 21 ka, 95 kv BIL, 0.55bG SE6-B1/21 CE6-B3/21 CE6-B5/21 General arrangement drawing RMINST-01 Page 90 RMINST-01 Page 90 RMINST-01 Page 90 Schematic drawing N/A RMSCH-21 Page 129 Key: b Standard feature v Factory fi tted accessory O Loose accessory, assembled on site (1) Only required when unit is used with RE2c ring main units and automation. RMSCH-22 Page AMTED399086EN.indd
81 Circuit breaker, metering and switches Extensible bus-section 630 A SE6-B1 DE60204 Bus-section disconnector Protection & control Non-automatic Documents Installation drawing ref: RMINST-01 Schematic drawing ref: N/A Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 95 kv Operating mechanism Independent manual Standard features RH busbar earth switch, 21 ka 3 s Anti-refl ex operating handle Indication Mechanical ON/OFF indicator Mechanical earth/main indicator Gas pressure indicator Test facility Integral RH busbar test facility Cable N/A Accessories VPIS indication Interlocks Busbars See page 78 for details Order information Code SE6-B1/21 Rating 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 79
82 Circuit breaker, metering and switches Extensible bus-section 630 A CE6-B3 DE60258 Bus-section circuit breaker Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 800/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Metering transformers b Metering CT s v 400/200/5 A v 10 VA class 0.5s b Metering VT ph-ph v 11 kv/110 V 50 VA v class 0.5 Documents Installation drawing ref: RMINST-01 Schematic drawing ref: RMSCH-21 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Standard features RH busbar earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Ammeter A Indication CT Y ph- 600/5 A class VA Gas pressure indicator Test facility Integral RH busbar test facility Cable N/A Accessories VPIS indication Interlocks Busbars See page 78 for details Order information Code CE6-B3/16 CE6-B3/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL 80 AMTED399086EN.indd
83 Circuit breaker, metering and switches Extensible bus-section 630 A CE6-B5 DE60259 Bus-section circuit breaker Protection & control - CB Self powered IDMT overcurrent and earth fault relay, VIP 300. In accordance with IEC and BS142. Protection CT s - 800/1 A class X Shunt trip coil, 20 V DC-250 V AC b Setting range: v Overcurrent: A v Earth fault: A Metering transformers b Metering CT s v 400/200/5 A v 10 VA class 0.5s b Metering VT ph-ph v 11 kv/110 V 50 VA v class 0.5 Documents Installation drawing ref: RMINST-01 Schematic drawing ref: RMSCH-22 Environment Indoor/outdoor IP54 Ratings Busbars 630 A Short time withstand 16/21 ka 3 s Internal arc 16/21 ka 1 s IAC class AF, A-FLR available on gas enclosure only Normal current rating 630 A Normal rated voltage 13.8 kv Normal rated BIL 75/95 kv Operating mechanism Independent manual Provision for actuator, 24 V DC Standard features RH busbar earth switch, 16/21 ka 3 s Anti-refl ex operating handle Indication Mechanical tripped on fault fl ag indicator Mechanical ON/OFF indicator Mechanical earth/main indicator Auxiliary contacts,1no 2 NC Earth selected auxiliary contacts1no Ammeter A Indication CT Y ph- 600/5 A class VA Gas pressure indicator Test facility Integral RH busbar test facility Cable N/A Accessories Actuator, 24 V DC VPIS indication Interlocks Busbars See page 78 for details Order information Code CE6-B5/16 CE6-B5/21 Rating 16 ka, 12 kv, 75 kv BIL 21 ka, 13.8 kv, 95 kv BIL AMTED399086EN.indd 81
84 82 AMTED399086EN.indd
85 Remote control Contents Telecontrol cabinet Easergy T200 E - Specifi cation Easergy T200-E02M Easergy T200-E04M AMTED399086EN.indd 83
86 Remote control Telecontrol cabinet Easergy T200 E - Specification Easergy T200-E02M 2 functions Environment Indoor / outdoor b b IP54 b b Communication Modbus IEC and IEC b b DNP3 b b 2 additional modem ports with GSM or GPRS b b Standard features Freestanding/wall mounted/ switchgear mounted b b Removable radio bracket ( no radio supplied) b b Inputs to cabinet Switch open - per switch b b Switch closed - per switch b b Earth selector earth/mains - per switch b b 1 spare - per switch b b Control output to switchgear To switch - Open switch b b - Close switch b b - Reset external FPI b b Output to SCADA - Switch open b b - Switch closed b b - Earth selector earth/main b b - Fault passage indication - phase and/or earth fault b b From cabinet - Local/remote failure b b - Mains/equipment failure b b - Battery and charger alarms b b Local control Push button open/close switch b b Local/remote selector b b Reset/test integral FPI b b Power restart b b Local indication Mains present b b Battery fault b b Internal supplies on b b Switch status - open/closed b b FPI operated b b Local/remote mode selected b b Equipment fault (watchdog) b b Battery and charger Telecomms equipment - 12 V DC b b Control unit - 12 V DC b b Power supply V AC 50 Hz 120 VA b b Switchgear 24 V DC b b 1 x 24 Ah sealed lead acid b b 20 degrees C, 3 hours after loss of supply b b 5 c/o switch operations b b Key: b Standard feature O Optional feature Easergy T200-E04M 4 functions 84 AMTED399086EN.indd
87 Remote control Telecontrol cabinet Easergy T200-E02M Easergy T200-E04M DE60195 Telecontrol cabinet - Up to 2 switch control (T200-E02M) Telecontrol cabinet - Up to 4 switch control (T200-E04M) Local indication Mains failure, battery fault, internal supplies on, Switch status - open/closed, FPI operated, local/remote mode selected, equipment fault (Watchdog) Inputs to cabinet Switch open Switch closed Earth selector earth/mains 3 spare Control outputs to switchgear b To switch v Open switch v Close switch v Reset FPI Local control Push button open/close switch Local/remote selector Reset/test integral FPI Optional features b Integral phase and earth fault passage indicator b 3 phase RMS current measurement b Wall mounted/freestanding Documents Installation drawing ref: RMINST-11 Schematic drawing ref: RMSCH-17 Environment Indoor/outdoor IP54 Dimensions 480 x 370 x 280 mm Communication b Modbus v IEC and IEC v DNP3 v 2 additional modem ports with GSM or GPRS Standard features Switchgear mounted removable radio bracket ( no radio/modem supplied) Outputs to SCADA b Switch open b Switch closed b Earth selector earth/main b Fault passage indication - phase and/or earth fault b From cabinet v Local/remote mode v Mains/equipment failure v other confi gurable alarms Batteries and charger Telecomms equipment - 12 V DC Control unit - 12 V DC Switchgear - 24 V DC 1 x 24 Ah sealed lead acid Power supply V AC 50 Hz 120 VA Autonomy 20 C 5 hours after loss of supply 5 C/O switch operations Deep discharge protection Order information T200-E02M T200-E04M AMTED399086EN.indd 85
88 86 AMTED399086EN.indd
89 Installation drawings Contents Summary 88 Typical switchboard 89 Extensible units ref RMINST-01, RMINST-02, RMINST-03 Non-extensible unit ref RMINST-04 Extensible ring main unit c/w tee off cable box - ref RMINST-22 Non-extensible ring main units for transformer mounting unit - ref RMINST-06 c/w MU2 metering unit & tee off cable box - ref RMINST-08 Non-extensible metering unit ref RMINST-07 Telecontrol cabinet ref RMINST AMTED399086EN.indd 87
90 Installation drawingssummary Non-extensible equipment Ring main units 200 A Ring main units 630 A Circuit breakers 200 A Switches 630 A Metering units Telecontrol cabinets RN2c-T1 RN2c-T2 RN2c-T3 RN2c-T4 RN2c-T5 RN2c-T25B RN2c-T25BS RN2c-T25A RN2c-T25AS RN6c-T1 RN6c-T25B RN6c-T25BS RN6c-T25A RN6c-T25AS CN2-T1 CN2-T6 CN2-T25B CN2-T25BS CN2-T25A CN2-T25AS SN6-S1 SN6-S2 MU2-M1, MU2-M2, MU2-M3 MU6-N1, MU6-N2, MU6-N3 MU6-N5 Easergy T200-E02M Easergy T200-E04M Schematic diagram RMSCH-01 RMSCH-03 RMSCH-02 RMSCH-15 RMSCH-01 RMSCH-43 RMSCH-44 RMSCH-45 RMSCH-46 RMSCH-42 RMSCH-43 RMSCH-44 RMSCH-45 RMSCH-46 RMSCH-26 RMSCH-11 RMSCH-47 RMSCH-48 RMSCH-49 RMSCH-50 N/A RMSCH-28 RMSCH-14 RMSCH-14 RMSCH-14 RMSCH-17 RMSCH-17 Page number General arrangement drawing RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-04 RMINST-06 RMINST-03 RMINST-03 RMINST-03 RMINST-03 RMINST-04 RMINST-04 RMINST-07/08 RMINST-07/08 RMINST-07/08 RMINST-11 RMINST-11 Page number Extensible equipment Ring main units 200 A Circuit breakers 200 A Circuit breakers 630 A Switches 630 A Bus sections 630 A RN2c-T1 RN2c-T2 RN2c-T3 RN2c-T4 RE2c-T25B RE2c-T25BS RE2c-T25A RE2c-T25AS CE2-T2 CE2-T3 CE2-T7 CE2-T11 CE2-T12 CE2-T13 CE2-T14 CE2-T15 CE2-T16 CE2-T19 CE2-T20 CE2-T21 CE2-T25B CE2-T25BS CE2-T25A CE2-T25AS CE6-T4 CE6-T5 CE6-T6 CE6-T8 CE6-T9 CE6-T10 CE6-T22 CE6-T23 CE6-T24 CE6-T25B CE6-T25BS CE6-T25A CE6-T25AS SE6-S1 SE6-S2 SE6-E1 SE6-B1 CE6-B3 CE6-B5 Schematic diagram RMSCH-01 RMSCH-03 RMSCH-02 RMSCH-15 RMSCH-43 RMSCH-44 RMSCH-45 RMSCH-46 RMSCH-07 RMSCH-09 RMSCH-06 RMSCH-09 RMSCH-19 RMSCH-20 RMSCH-20 RMSCH-12 RMSCH-13 RMSCH-35 RMSCH-35 RMSCH-36 RMSCH-47 RMSCH-48 RMSCH-49 RMSCH-50 RMSCH-08 RMSCH-10 RMSCH-10 RMSCH-23 RMSCH-24 RMSCH-24 RMSCH-37 RMSCH-38 RMSCH-37 RMSCH-47 RMSCH-48 RMSCH-49 RMSCH-50 N/A RMSCH-29 N/A N/A RMSCH-21 RMSCH-22 Page number General arrangement drawing RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-06 RMINST-03 RMINST-02 RMINST-03 RMINST-02 RMINST-03 RMINST-02 RMINST-02 RMINST-03 RMINST-03 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-03 RMINST-02 RMINST-02 RMINST-03 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-02 RMINST-03 RMINST-03 RMINST-03 RMINST-01 RMINST-01 RMINST-01 Page number AMTED399086EN.indd
91 Installation drawingstypical switchboard DE Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd 89
92 Installation drawings Extensible unit ref RMINST-01 DE Panel type Page number SE6-B1 79 CE6-B3 80 CE6-B5 81 Approximate weight: 450 kg Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd
93 Installation drawings Extensible unit ref RMINST-02 DE Panel type Page number CE2-T3 58 CE2-T11 58 CE2-T13 61 CE2-T14 60 CE2-T19 58 CE2-T20 58 CE2-T21 60 CE6-T5 68 CE6-T6 68 CE6-T9 71 CE6-T10 71 CE6-T22 68 CE6-T23 71 CE6-T24 68 Approximate weight: 450 kg Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd 91
94 Installation drawings Extensible unit ref RMINST-03 DE Panel type Page number CE2-T2 56 CE2-T7 57 CE2-T12 59 CE6-T4 67 CE6-T8 69 SE6-S1 74 SE6-S2 75 SE6-E1 76 Approximate weight: 250 kg Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd
95 Installation drawingsnon-extensible unit ref RMINST-04 DE59811 Panel type Page number CN2-T1 38 CN2-T6 39 SN6-S1 43 SN6-S2 44 Approximate weight: 250 kg Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd 93
96 Installation drawings Extensible ring main unit c/w tee off cable box ref RMINST-22 DE Panel type Page number RE2c-T1 30 RE2c-T2 31 RE2c-T3 32 RE2c-T4 33 Approximate weight: 300 kg Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd
97 Installation drawings Non-extensible ring main unit for transformer mounting unit ref RMINST-06 DE60268 DE59812 Panel type Page number RN2c-T1 19 RN2c-T2 20 RN2c-T3 21 RN2c-T4 22 RN2c-T5 23 RN6c-T1 25 Approximate weight: 300 kg Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd 95
98 Installation drawings Non-extensible ring main unit c/w MU2 metering unit & tee off cable box ref RMINST-08 DE59814 Panel type Page number MU2-M1 47 MU2-M2 48 MU2-M3 49 MU6-N1 52 MU6-N2 52 MU6-N3 52 MU6-N5 52 Approximate weight: 200 kg (MU2 only) MU2 shown connected to a non-extensible ring main unit Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd
99 Installation drawings Non-extensible metering unit ref RMINST-07 DE59813 Panel type Page number MU2-M1 47 MU2-M2 48 MU2-M3 49 MU6-N1 52 MU6-N2 52 MU6-N3 52 MU6-N5 52 Approximate weight: 450 kg Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd 97
100 Installation drawings Telecontrol cabinet ref RMINST-11 DE59815 DE60268 Panel type Page number Easergy T200-E02 85 Easergy T200-E04 85 Approximate weight: 30 kg (Easergy only) Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) Note: for civil engineering and recommendations for internal arc clearances please consult our installation and maintenance instructions Ref: SE 6251 or contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd
101 Schematic diagrams Contents Schematic legends Specifi cation 100 Ring main units accessories 102 Non-extensible / extensible ring main units ref RMSCH-01, RMSCH-02, RMSCH-03, RMSCH-15, RMSCH-43, RMSCH-44, RMSCH-45, RMSCH-46 Non-extensible ring main unit RMSCH-42 Non-extensible metering unit ref RMSCH-14 Non-extensible / extensible circuit breaker units ref RMSCH-47, RMSCH-48, RMSCH-49, RMSCH-50 Non-extensible circuit breaker units ref RMSCH-11, RMSCH-26 Extensible circuit breaker units ref RMSCH-06, RMSCH-07, RMSCH-08, RMSCH-09, RMSCH-10, RMSCH-12, RMSCH-13, RMSCH-19, RMSCH-20, RMSCH-21, RMSCH-22, RMSCH-23, RMSCH-24 RMSCH-35, RMSCH-36, RMSCH-37, RMSCH-38 Non-extensible switch units ref RMSCH-28, RMSCH-29 Telecontrol unit block diagram ref RMSCH AMTED399086EN.indd 99
102 Schematic diagramsschematic legends Specification DE60269 Fuse schedule F1 F2 Legends EPS MR RL1 RL TFL /b /a /c A STC ITC N 51N INC M EFPI EPSR EPSL ESR ESL TRS Symbols VT secondary 16 A/link metering VT secondary 2 A/link metering earth position selected auxiliary mechanism reset switch close relay open relay circuit breaker switch direct acting trip coil time fuse link normally closed auxiliary contact normally open auxiliary contact normally open make auxiliary contact ammeter shunt trip coil integral trip coil instantaneous overcurrent time delayed overcurrent instantaneous earth fault time delayed earth fault minimum operating current actuator earth fault passage indicator earth position selector right earth position selector left earth switch right earth switch left trip reset spring CT & VT Ratios Panel type CT1 CT2 CT3 CT4 VT1 VT2 RN2c-T1 100/50/5 A Class X RN2c-T2 200/1 A Class X RN2c-T3 500/200/1 A Class X RN2c-T4 500/200/1 A Class X RN2c-T5 100/50/5 A Class X RN2c-T25 200/100/1 A 5P20 RN6c-T1 800/400/1 A Class X RN6c-T25 800/400/1 A 5P20 RE2c-T1 100/50/5 A Class X RE2c-T2 200/1 A Class X RE2c-T3 500/200/1 A Class X RE2c-T4 500/200/1 A Class X RE2c-T25 200/100/1 A 5P20 MU2-M1 MU2-M2 MU2-M3 CN2-T1 CN2-T6 CN2-T25 CE2-T7 CE2-T2 CE2-T3 CE2-T11 CE2-T12 CE2-T13 CE2-T14 CE2-T15 CE2-T16 CE2-T19 CE2-T20 CE2-T21 CE2-T25 200/1 A Class X 100/50/5 A Class X 200/100/1 A 5P20 100/50/5 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/1 A Class X 200/100/1 A 5P20 50/25/5 A 7.5 VA Class 0.5s 100/50/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 200/100/5 A 10 VA Class 0.5s 11000/110 V 50 VA Class /110 V 50 VA Class /110 V 50 VA Class /110 V 50 VA Class /110 V 50 VA Class /110 V 50 VA Class /110 V 50 VA Class /110 V/110 V 50 VA Class VA class 3 P 11000/110 V/110 V 50 VA Class VA class 3 P 13800/110 V/110 V 50 VA Class VA class 3 P 100 AMTED399086EN.indd
103 Schematic diagramsschematic legends Specification Conditions 1. All relays de-energised 2. Switches shown in open position 3. Auxiliary switch only operated between main ON and main OFF position (i.e. does not operate in earth position). CT and VT types CTI CT2 CT3 CT4 VT1 VT2 3 phase protection CT s 1 phase indication CT 2 phase metering CT Easergy 200E phase & earth fault Ct Ph-Ph metering VT (2 phases) Ph-E metering VT (3 phases) CT & VT Ratios Panel type CT1 CT2 CT3 CT4 VT1 VT2 CE6-T4 CE6-T5 CE6-T6 CE6-T8 CE6-T9 CE6-T10 CE6-T22 CE6-T23 CE6-T24 CE6-T25 CE6-B3 CE6-B5 SE6-S2 SN6-S2 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/400/1 A 5P20 800/1 A Class X 800/1 A Class X 800/1 A Class X 800/1 A Class X 600/5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /5 A 5 VA Class /200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 400/200/5 A 10 VA Class 0.5s 500/1 A Class X 500/1 A Class X 11000/110 V 50 VA Class /110 V 50 VA Class /110 V 50 VA Class /110 V 50 VA Class /110 V/110 V 50 VA Class VA class 3 P 13800/110 V/110 V 50 VA Class VA class 3 P 11000/110 V/110 V 50 VA Class VA class 3 P 11000/110 V 50 VA Class /110 V 50 VA Class 0.5 AMTED399086EN.indd 101
104 Schematic diagrams Ring main units accessories DE59820 L1 L2 L3 102 AMTED399086EN.indd
105 Schematic diagrams Ring main units accessories Circuit breaker DE59821 AMTED399086EN.indd 103
106 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-01 DE59822 L1 L 2 L3 Panel type Page number RN2c-T1 19 RE2c-T1 30 For explanation of symbols see page AMTED399086EN.indd
107 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-02 DE59824 L1 L 2 L3 Panel type Page number RN2c-T3 21 RE2c-T3 32 For explanation of symbols see page 100 AMTED399086EN.indd 105
108 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-03 DE59823 L1 L 2 L3 Panel type Page number RN2c-T2 20 RE2c-T2 31 For explanation of symbols see page AMTED399086EN.indd
109 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-15 DE59825 L1 L 2 L3 Panel type Page number RN2c-T4 22 RE2c-T4 33 For explanation of symbols see page 100 AMTED399086EN.indd 107
110 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-43 DE59853 Panel type Page number RN2c-T25 24 RE2c-T25 34 For explanation of symbols see page AMTED399086EN.indd
111 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-44 DE59854 Panel type Page number RN2c-T25 24 RE2c-T25 34 For explanation of symbols see page 100 AMTED399086EN.indd 109
112 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-45 DE59855 Panel type Page number RN2c-T25 24 RE2c-T25 34 For explanation of symbols see page AMTED399086EN.indd
113 Schematic diagrams Non-extensible / extensible ring main unit ref RMSCH-46 DE59856 Panel type Page number RN2c-T25 24 RE2c-T25 34 For explanation of symbols see page 100 AMTED399086EN.indd 111
114 Schematic diagrams Non-extensible ring main unit ref RMSCH-42 DE59826 L1 L 2 L3 Panel type Page number RN6c-T1 25 For explanation of symbols see page AMTED399086EN.indd
115 Schematic diagrams Non-extensible metering unit ref RMSCH-14 DE59834 L1 L3 Panel type Page number MU2-M1 47 MU2-M2 48 MU2-M3 49 MU6-N1 52 MU6-N2 52 MU6-N3 52 MU6-N5 52 For explanation of symbols see page 100 AMTED399086EN.indd 113
116 Schematic diagrams Non-extensible / extensible circuit breaker units ref RMSCH-47 DE59857 Panel type Page number CN2-T25 40 CE2-T25 64 CE6-T25 70 For explanation of symbols see page AMTED399086EN.indd
117 Schematic diagrams Non-extensible / extensible circuit breaker units ref RMSCH-48 DE59858 Panel type Page number CN2-T25 40 CE2-T25 64 CE6-T25 70 For explanation of symbols see page 100 AMTED399086EN.indd 115
118 Schematic diagrams Non-extensible / extensible circuit breaker units ref RMSCH-49 DE59859 Panel type Page number CN2-T25 40 CE2-T25 64 CE6-T25 70 For explanation of symbols see page AMTED399086EN.indd
119 Schematic diagrams Non-extensible / extensible circuit breaker units ref RMSCH-50 DE59860 Panel type Page number CN2-T25 40 CE2-T25 64 CE6-T25 70 For explanation of symbols see page 100 AMTED399086EN.indd 117
120 Schematic diagramsnon-extensible circuit breaker units ref RMSCH-11 DE59833 L1 L 2 L3 Panel type Page number CN2-T6 39 For explanation of symbols see page AMTED399086EN.indd
121 Schematic diagramsnon-extensible circuit breaker units ref RMSCH-26 DE59843 L1 L 2 L3 Panel type Page number CN2-T1 38 For explanation of symbols see page 100 AMTED399086EN.indd 119
122 Schematic diagrams Extensible circuit breaker units ref RMSCH-06 DE59828 L1 L 2 L3 Panel type Page number CE2-T7 57 For explanation of symbols see page AMTED399086EN.indd
123 Schematic diagrams Extensible circuit breaker units ref RMSCH-07 DE59829 L1 L 2 L3 Panel type Page number CE2-T2 56 For explanation of symbols see page 100 AMTED399086EN.indd 121
124 Schematic diagrams Extensible circuit breaker units ref RMSCH-08 DE59830 L1 L 2 L3 L 2 Panel type Page number CE6-T4 67 For explanation of symbols see page AMTED399086EN.indd
125 Schematic diagrams Extensible circuit breaker units ref RMSCH-09 DE59831 L1 L 2 L3 L1 L3 Panel type Page number CE2-T3 58 CE2-T11 58 For explanation of symbols see page 100 AMTED399086EN.indd 123
126 Schematic diagrams Extensible circuit breaker units ref RMSCH-10 DE59832 L1 L 2 L3 L 2 L 2 L1 L3 Panel type Page number CE6-T5 68 CE6-T6 68 For explanation of symbols see page AMTED399086EN.indd
127 Schematic diagrams Extensible circuit breaker units ref RMSCH-12 DE59835 L1 L 2 L3 Panel type Page number CE2-T15 62 For explanation of symbols see page 100 AMTED399086EN.indd 125
128 Schematic diagrams Extensible circuit breaker units ref RMSCH-13 DE59835 L1 L 2 L3 Panel type Page number CE2-T16 63 For explanation of symbols see page AMTED399086EN.indd
129 Schematic diagrams Extensible circuit breaker units ref RMSCH-19 DE59837 L1 L 2 L3 Panel type Page number CE2-T12 59 For explanation of symbols see page 100 AMTED399086EN.indd 127
130 Schematic diagrams Extensible circuit breaker units ref RMSCH-20 DE59838 L1 L 2 L3 L1 L3 Panel type Page number CE2-T13 61 CE2-T14 60 For explanation of symbols see page AMTED399086EN.indd
131 Schematic diagrams Extensible circuit breaker units ref RMSCH-21 DE59839 L1 L 2 L3 L 2 L1 L3 Panel type Page number CE6-B3 80 For explanation of symbols see page 100 AMTED399086EN.indd 129
132 Schematic diagrams Extensible circuit breaker units ref RMSCH-22 DE59840 L1 L 2 L3 L 2 L1 L3 Panel type Page number CE6-B5 81 For explanation of symbols see page AMTED399086EN.indd
133 Schematic diagrams Extensible circuit breaker units ref RMSCH-23 DE59841 L1 L 2 L3 L 2 Panel type Page number CE6-T8 69 For explanation of symbols see page 100 AMTED399086EN.indd 131
134 Schematic diagrams Extensible circuit breaker units ref RMSCH-24 DE59842 L1 L 2 L3 L 2 L1 L3 Panel type Page number CE6-T9 71 CE6-T10 71 For explanation of symbols see page AMTED399086EN.indd
135 Schematic diagrams Extensible circuit breaker units ref RMSCH-35 DE59846 L1 L 2 L3 L1 L 2 L3 Panel type Page number CE2-T19 58 CE2-T20 58 For explanation of symbols see page 100 AMTED399086EN.indd 133
136 Schematic diagrams Extensible circuit breaker units ref RMSCH-36 DE59847 L1 L 2 L3 L1 L 2 L3 Panel type Page number CE2-T21 60 For explanation of symbols see page AMTED399086EN.indd
137 Schematic diagrams Extensible circuit breaker units ref RMSCH-37 DE59848 L1 L 2 L3 L 2 L1 L 2 L3 Panel type Page number CE6-T22 68 CE6-T24 68 For explanation of symbols see page 100 AMTED399086EN.indd 135
138 Schematic diagrams Extensible circuit breaker units ref RMSCH-38 DE59849 L1 L 2 L3 L 2 L1 L 2 L3 Panel type Page number CE6-T23 71 For explanation of symbols see page AMTED399086EN.indd
139 Schematic diagrams Non-extensible switch units ref RMSCH-28 DE59844 L1 L 2 L3 Panel type Page number SN6-S2 44 For explanation of symbols see page 100 AMTED399086EN.indd 137
140 Schematic diagrams Non-extensible switch units ref RMSCH-29 DE59845 L1 L 2 L3 Panel type Page number SE6-S2 75 For explanation of symbols see page AMTED399086EN.indd
141 Schematic diagrams Telecontrol unit block diagram ref RMSCH-17 DE59827 L V AC 50 Hz L2 L3 Panel type Page number Easergy T200-E02M 85 Easergy T200-E04M 85 For explanation of symbols see page 100 AMTED399086EN.indd 139
142 140 AMTED399086EN.indd
143 Accessories Contents Summary 142 Description 143 Non-extensible ring main unit c/w angled ring cable gland plates - ref RMINST-05 Tee-off cable box fitted to SN6/CN2 ref RMINST-09 Ringmaster range cabling accessories ref RMINST Protection options 147 AMTED399086EN.indd 141
144 AccessoriesSummary Schneider Electric are able to provide a number of accessories to enhance the basic unit specifi cations. These accessories are detailed within the panel type specifi cations Accessories These are dispatched either: b Fitted to the unit within the works - these are accessories that are either too bulky, or need testing prior to despatch ie; RMR-F47 - tee-off cable box b Loose, boxed, for you to assemble on site. These items are either those that need to be supplied loose to ease installation: ie RMR-A48 which is a gland plate, or test equipment such as RMR-A202, VAP6. Options The following pages clarify options: RMR-F47 - Tee-off cable box (drawing RMINST 05/09) RMR-A50 - Angled gland tray (drawing RMINST 10) RMR-A317 - Angled gland tray (drawing RMINST 05) 142 AMTED399086EN.indd
145 AccessoriesDescription DE60245 DE60270 RMR-A14/A15/A78/A79 Busbar assemblies b Each kit comprises a three phase set of busbars, 630 A b Specify at time of ordering: v 1 off RMR-A15 - end panel kit, plus busbar kits v Quantity required = No. of panels - 1 Note: Different busbar kits are required for metering units and bus-sections Busbars are dispatched loose. RMR-A17 Time fuse links b 2 off time fuse links for overcurrent protection Order code RMR-A17/3 RMR-A17/5 RMR-A17/7 RMR-A17/10 RMR-A17/12 RMR-A17/15 Rating 3 amp 5 amp 7.5 amp 10 amp 12.5 amp 15 amp PE58310 RMR-A202 VAP 6 test unit b Check operation of VIP 300, VIP 30 & VIP35 IDMT relays, unit injects 20 x Is to verify operation of microprocessor and outputs, and trip the CB. Complete with batteries. AMTED399086EN.indd 143
146 Accessories Non-extensible ring main unit c/w angled ring cable gland plates ref RMINST-05 DE Panel type Page number RN2c-T1 19 RN2c-T2 20 RN2c-T3 21 RN2c-T4 22 RN2c-T5 23 Approximate weight: 300 kg The above drawings refer to RMR-F324 tee-off cable box and RMR-A317 angled gland plate. Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd
147 Accessories Tee-off cable box fitted to SN6/CN2 ref RMINST-09 DE60247 Panel type Page number CN2-T1 38 CN2-T6 39 SN6-S1 43 SN6-S2 44 Note: for installation where overpressure relief of the equipment is required please contact Schneider Electric Tel: +44 (0) AMTED399086EN.indd 145
148 Accessories Ringmaster range cabling accessories ref RMINST-10 DE Panel type Page number CE CE SE CN SN Approximate weight: 250 kg 146 AMTED399086EN.indd
149 AccessoriesProtection options Three types of protection systems are available for Ringmaster b Time Fuse Links - CT operated trip coils with provision for Time Fuse Links (TFL). b VIP Protection relays - self-powered IDMT, DT overcurrent and earth fault relays. b Sepam series 10 - IDMT, DT overcurrent, earth fault and thermal overload with advanced functions and Modbus. TFL protection An effective low cost option without compromising reliability. CT operated trip coils (with TFL) provides phase overcurrent and earth fault inverse time protection, the characteristic being given by a Time Fuse Link (TFL). This option is suitable for transformer protection up to 1600 kva. Recommended Time Fuse Link (TFL) settings to ESI 12-6 Voltage Transformer rated power (kva) (kv) CT ratio = 50/ A TFL earth fault setting = 25 A (instantaneous trip) 150 A LV fuse A 10 A 15 A TFL 150 A 250 A 400 A LV fuse 11 3 A 5 A 10 A 15 A TFL 200 A 300 A 400 A 560 A LV fuse A 5 A 10 A 15 A TFL 200 A 300 A 400 A 560 A LV fuse CT ratio = 100/ A 10 A 15 A TFL earth fault setting = 30 A (instantaneous trip) 150 A 250 A 400 A LV fuse A 7.5 A 12.5 A 15 A TFL 250 A 400 A 560 A 560 A LV fuse 11 5 A 7.5 A 10 A 12.5 A 15 A TFL 400 A 560 A 630 A 630 A 630 A LV fuse A 7.5 A 10 A 12.5 A 15 A TFL 400 A 560 A 630 A 630 A 630 A LV fuse DE60249 Benefits b Low cost b Fast clearance of LV faults b Simple to replace b Proven protection to EA standards b Fast tripping for MV earth faults b Improved discrimination with LV fuse Principle of operation The current transformer feeds a trip coil that is normally shunted by a time fuse link. In the event of a fault the fuse ruptures, diverting all the fault current through the trip coil, tripping the breaker. A residually connected trip coil provides instantaneous earth fault protection. Protection application guide Product CE2, CN2, RN2c, RE2c CE6, RN6c Application Transformers Transformers Ring feeders Incomers kva kva kva kva kva Time fuse Link b IDMT VIP 300 b b b b Note: a protection co-ordination study may be necessary to verify the type of protection. Consult your local Schneider Electric sales engineer if in doubt. Protection selection guide Primary current (A) Equivalent transformer rating at 11 kv 200 kva 400 kva 1600 kva 1900 kva 2400 kva 3800 kva kva Application Panel Protection Transformer protection Feeder protection CE2/CN2 Time Fuse Link b b b RE2c/RN2c IDMT - VIP 30/35 b b b b b RE2c/RN2c IDMT - VIP 300 b b b b b CE6/RN6c IDMT - VIP 300 b b b b AMTED399086EN.indd 147
150 148 AMTED399086EN.indd
151 Schneider Electric, an overview and order form Contents Overview Building systems and solutions Industrial systems and solutions Energy and infrastructure systems and solutions Order form Ring Main Unit (RMU) Ring Modular Range (RMR) Index 156 AMTED399086EN.indd 149
152 Schneider Electric, an overview and order form Overview PE58311 With over 100 years experience in the electrical industry, Schneider Electric has established itself as a world leader in the supply and manufacture of products for the distribution, monitoring and control of electrical power. Schneider Electric regards its customers as commercial partners, who, like us, demand the highest standards of excellence in terms of products, projects and services. Schneider Electric is proud to provide the solutions to meet their needs. Schneider Electric operates the largest, dedicated sales force in the electrical industry. Sales engineers have specialist expertise and an understanding of the customer needs within each of the following market sectors: b Building systems and solutions b Industrial systems and solutions b Energy and infrastructure systems and solutions. 150 AMTED399086EN.indd
153 Schneider Electric, an overview and order form Overview Building systems and solutions PE58312 The real reason for putting technology into buildings is to simplify tasks, enhance safety and improve the quality of life. Schneider Electric knows this and has created attractive, functional products for the residential building sector. Well being comfort and entertainment are key concepts in this area. The same objectives apply to commercial buildings such as offi ces, hotels, shopping centres, hospitals, schools and care facilities for the elderly. Schneider Electric offer a wide range of solutions in the area of building management services and uses its expertise in all of these buildings to protect people and equipment. PE58313 Schneider Electric means greater comfort, lower operating costs and enhanced safety. Related industries b Retail b Education b Health b Entertainment centres b Offi ces b Warehouses b Agriculture b Factory b Private residential b Public residential. Principal customers in the construction market b Contracting authorities b Main contractors b Building engineers. AMTED399086EN.indd 151
154 Schneider Electric, an overview and order form Overview Industrial systems and solutions Schneider Electric focus on performance in all areas of industry. Our products and services adapt to each specifi c business and environment, from discrete manufacturing and production lines to continuous processes in a wide variety of industries such as: b Automotive b Food and beverage b Pharmaceuticals b Construction materials b Waste management. Across a wide range of applications including: b Conveyors b Packaging b Materials handling b Hoisting. PE57008 PE AMTED399086EN.indd
155 Schneider Electric, an overview and order form Overview Energy and infrastructure systems and solutions PE58315 PE58316 Schneider Electric is involved in the entire electrical distribution chain from power plants to end users. Customer demand for complete availability, uncompromising quality and absolute safety has made the search for excellence our key mission. Today, electrical substation and network protection, monitoring and control are highly effective in reducing outage time. Proven technologies offer a wide range of simple, effi cient and fl exible solutions for optimised, step by step investments. Infrastructure Schneider Electric is involved in developing infrastructure and transportation systems around the world. In areas where no failures can be tolerated, such as road and rail equipment, harbour installations and airports, Schneider Electric provides solutions in electrical distribution, control and monitoring, automation and supervision. Key markets b Electricity distribution b Water b Rail b Airports b Seaports b Defence b Gas b Telecommunications b Road. Principal customers in the electric power market b Power suppliers involved in generation and distribution b Utility companies b Major contractors b Large end user sites b Government departments. AMTED399086EN.indd 153
156 Schneider Electric, an overview and order form Order form Ring Main Unit (RMU) Only one of the boxes (ticked X or fi lled by the needed value) have to be considered between each horizontal line. Green box X corresponds to none priced functions. Basic RMU configuration Quantity Rated voltage Ur (kv) Impulse rating and short-time withstand 21 ka 3 s, 95 kvbil RMU configuration and protection RN2c RE2c RE2c RN6c 200 A CB 200 A CB 200 A CB 630 A CB non extensible left and right right extensible non extensible Protection extensible TLF VIP 30 VIP 35 VIP 300 Sepam 10 Metering (when the metering option is chosen, the impulse rating and short-time withstand are reduced at 16 ka 1 s, 75 kvbil) Options for circuit breaker Transformer Freestanding Freestanding mounted top bottom RN2c and RE2c RN6c Operational items Shunt trip coil Vdc, Vac/dc Motor pack (remote electrical operation) 24 Vdc 30 Vdc Mechanical key interlock (not available with motor option) key free main OFF Key free earth ON Circuit breaker cable test facility Low gas pressure switch Mechanical trip push button VPIS (only with freestanding option) kv kv Options for ring switch 1 - left hand side Remote electrical indication (auxiliary switch) 1 x N/O, 1x N/C Motor pack (remote electrical operation) 24 Vdc 30 Vdc Mechanical key interlock (not available with motor option) Key free main OFF Key free earth ON MV cable entry RN2c and RE2c Top Bottom RN6c Bottom Earth fault passage indication (includes external current transformer) Bardin Flair 212 Horstman Earth/M 2.0 Easergy T200 current transformers Voltage Presence Indication VPIS kv kv Options for ring switch 2 - right hand side Remote electrical indication (auxiliary switch) 1 x N/O, 1x N/C Motor pack (remote electrical operation) 24 Vdc 30 Vdc Mechanical key interlock (not available with motor option) Key free main OFF Key free earth ON MV cable entry RN2c Top Bottom RE2c and RN6c Bottom Earth fault passage indication (includes external current transformer) Bardin Flair 212 Horstman Earth/M 2.0 Easergy T200 current transformers Voltage Presence Indication VPIS kv kv Busbar extension trunking (for RE2c to RMR circuit breaker or switch) RE2c only Accessories Phase comparitor VAP6 TLF fuses (A) Connection for Easergy - RMU Enter number of functions required 154 AMTED399086EN.indd
157 Schneider Electric, an overview and order form Order form Ring Modular Range (RMR) Only one of the boxes (ticked X or fi lled by the needed value) have to be considered between each horizontal line. Green box X corresponds to none priced functions. Basic RMR configuration Quantity Rated voltage Ur (kv) Short-circuit current Isc (ka) Load of circuit (A) Panel configuration and protection NON EXTENSIBLE I EXTENSIBLE CN2 SN6 MU2 CE2 CE6 SE6 200 A 630 A 200 A 200 A 630 A 200 A CB Switch Metering CB CB Switch Protection No protection TLF VIP 300 Sepam 10 Bus section Metering Options Freestanding Top Bottom Transformer mounted (direct connection) Shunt trip coil (multi ac/dc voltage range) Remote electrical operation (actuator 24 Vdc) Mechanical key free earth ON key interlock key free mean OFF Remote electrical operation (low gas pressure switch) NON EXTENSIBLE I EXTENSIBLE CN2 SN6 MU2 CE2 CE6 SE6 200 A 630 A 200 A 200 A 630 A 200 A CB Switch Metering CB CB Switch VPIS kv kv EFPI (includes external EFPI CT) Bardin Flair 212 Horstman Earth / M 2.0 Accessories Busbar End panel Phase comparitor VAP6 TLF fuses (A) Connection for Easergy - RMR Enter number of functions required AMTED399086EN.indd 155
158 Schneider Electric, an overview and order form Index A Page Accessories 142 Actuator panel types 41, 42, 53, 54, 65 Angled gland trays 142, 144 Applications 150 B Busbar options sections 143 Bus sections 77, 78 C 200 A 36, A 65, 66 Circuit breakers 53, 54 Control & protection 7, 147 D Drawing index 88 E Easergy telecontrol unit 84 EATS 6 I IDMT protection 147 IEC/BS standards 6 M Metered CB s 53, 54, 65, 66 Metering units 45, 46 Motor retrofi t 27, 28, 53, 54 P Protection selection 7, 147 Protection - TFL 7, 147 Protection - VI 7, 147 R Ring main units extensible 53, 54 Ring main units non-extensible 16, 17 S Schematics 100 Selection guide 14 Self powered protection 147 Switchboard GA 89 Switches 41, 42, 72, 73 T Telecontrol 84 Telephone communication 84 TFL protection 147 Time fuse links 147 V VIP protection 7, 147 Please note: Due to the constant progress in standards and equipment, the characteristics shown in the texts and images in this document are only binding once expressly confirmed by ourselves 156 AMTED399086EN.indd
159
160 Schneider Electric Industries SAS 335, rue Joseph Monier CS F Rueil Malmaison Cedex (France) Tél. : +33 (0) RCS Nanterre Capital social As standards, specifi cations and designs change from time to time, please ask for confi rmation of the information given in this publication. Design: Schneider Electric Industries SAS Photos: Schneider Electric Industries SAS Printed: Altavia Connexion - Made in France This document has been printed on recycled paper AMTED399086EN ART45334 Schneider Electric Industries SAS - All rights reserved
Ring main units non-extensible 0
Specification Ring main units non-extensile 0 RN2c-T1 TFL RN2c-T2 VIP 300 RN2c-T3 VIP 30 RN2c-T4 VIP 35 RN2c-T5 Glass TFL RN6c-T1 VIP 300 Indoor / outdoor Transformer mounted Freestanding O O O O O Busars
Non-extensible circuit breakers
Specification Non-extensile circuit reakers 200A 0 CN2-T1 Indoor / outdoor Normal rated current 200A 12kV 16kA 3 seconds 75kV BIL 13.8kV 21kA 3 seconds 95kV BIL O O Cale earth switch 16kA 3 seconds Cale
Medium Voltage Distribution. Ringmaster. Ring Main Unit. Catalogue 2009
Medium Voltage Distriution Ringmaster Ring Main Unit Catalogue 2009 A new path for achieing your electrical installations A comprehensie offer The Ringmaster range is part of a comprehensie offer of products
Remote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear
Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear Index 3 Overview 4 Standard Levels 6 Monitoring & Control 7 Measurements 8 Protection & Logic
Relion 605 series. Self-powered feeder protection REJ603 Product Guide
Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
Trip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Catalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
GE Protection and Control Business Department. Page 1 Date 5/11/99
GE Protection and Control Business Department Page 1 GE Protection and Control Business Department Proven Overcurrent Protection with Power Management Communication The The Advantages of Microprocessor
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
Safe and secure distribution of medium voltage with AX1
Safe and secure distribution of medium voltage with AX1 The intelligent switchgear AX1 is a modern, air-insulated switchgear that lies at the very front line of safety and security safety for operating
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
How To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
Safety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
Nu-Lec Training Modules
PTCC Controller Nu-Lec Training Modules Product Training Operator Training PTCC The Basics An overview of the construction and physical features of the Pole Top Control Cubicle PTCC Operation and Features
A project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
An Alternative Approach to Improving SAIDI and SAIFI Indicators
An Alternative Approach to Improving SAIDI and SAIFI Indicators Philippe Deschamps - Schneider Electric Industries - France Jean-Christophe Orsini - Schneider Electric Industries - France Kaare Seest Rasmussen
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
Capacitor Protection Relay SPAJ 160 C. Product Guide
Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase
UFES Active protection for switchgear
Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document
For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690 V - 1000 V (at 50 Hz)
24 1. NETWORK CONFIGURATIONS definition Standard IEC 38 defines voltage ratings as follows: - Low voltage () For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V - 690
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
Medium voltage arc flash eliminator units VAM 3ED,
Medium voltage arc flash eliminator units VAM 3ED,, Medium voltage arc flash eliminator units Medium voltage arc flash eliminator units The new innovative arc eliminator VAM 3ED is an extremely fast acting
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series
Communication system for the management of electrical installations INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series MID Approval Technology for energy efficiency PLC Communications (Power Line Communication)
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Part 1 System Modeling & Studies for Existing Systems
Part 1 System Modeling & Studies for Existing Systems Operation Technology, Inc. Copyright 2009 Result of rapid release of energy due to an arcing fault between two conductors. Bus voltages > 208V Temperatures
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
What will MV switchgear look like in the future? by Jean-Marc Biasse
What will MV switchgear look like in the future? by Jean-Marc Biasse Table of contents Introduction... 2 Brief history of the technologies used in medium voltage switchgear and control gear... 4 Evolution
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
Circulating Current Relay. Type IRXm
Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002
INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002 NEW GAS INSULATED SWITCHGEAR (GIS) FOR ALL MEDIUM VOLTAGE APPLICATIONS H. Fink, ABB Calor Emag Mittelspannungs GmbH; M. Hyrenbach, ABB Calor
Current and voltage measuring relays
Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application
Fusible Disconnect Switch
Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Electrical network protection. Sepam series 10. Digital protection relays. Catalogue 2008
Electrical network protection Sepam series 0 Digital protection relays Catalogue 2008 Sepam series 0 Contents Introduction 3 Sepam protection relays, the product of experience 3 Selection guide for all
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A
AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components
Advantages of Fixed Circuit Breaker Switchgear
Advantages of Fixed Circuit Breaker Switchgear by Lionel Mackay, EDF Energy, and Mike Adams, Schneider Electric Ltd Introduction The purpose of this paper is to review the advantages of fixed circuit breaker
THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012
Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation
Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation Index News Introduction Applications & Segments Main Components Applicable Standards Technical characteristics
Relion 605 series. Feeder protection and control / Feeder protection REF601 / REJ601 Product Guide
Relion 605 series Feeder protection and control / Feeder protection Product Guide Product version: 2.2FP1 Contents 1. Description... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
Voltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
0Sepam series 20 Merlin Gerin
0Electrical network protection 0Sepam series 20 Merlin Gerin 0User 0Manual 02003 Contents Sepam series 20 1 Metering functions 2 Protection functions 3 Control and monitoring functions 4 Modbus communication
CAS 36 Ring Main Unit
Power distribution networks Ring Main Unit Catalogue 2008 A new path for achieving your electrical installations A comprehensive offer The range is part of a comprehensive offer of products that are perfectly
Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR
Switchgear Capabilities NexGear is a Division of PowerSecure NASDAQ: POWR Discussion Points Introducing PowerSecure Introducing NexGear Solutions Offered Scope of Services Examples of Work Q & A NexGear,
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE
SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy
ekorrp PROTECTION, METERING AND CONTROL UNITS
General Instructions PROTECTION, METERING AND CONTROL UNITS LIB Transformer Substations Secondary Distribution Switchgear Primary Distribution Switchgear Protection and Automation Low Voltage Boards Distribution
Permissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
SENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World
Catalogue 2002 Automatic capacitor banks Building a New Electric World 0Contents Power factor correction 2 Power factor equipment selection guide 3 General technical data 4 Capacitors and banks 50 z 6
FEDERAL ELECTRICITY & WATER AUTHORITY
UNITED ARAB EMIRATES FEDERAL ELECTRICITY & WATER AUTHORITY SPECIFICATION FOR 433 VOLTS SWITCHGEARS (LVAC BOARD) LVAC SWITCHBOARDS I N D E X CLAUSE TITLE 1. GENERAL 2. TEMPERATURE RISE 3. BUSBARS 4. CONSTRUCTION
Tmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
Low voltage electrical distribution. Electronic trip units. User manual 09/2009
Low voltage electrical distribution Electronic trip units User manual 09/2009 Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for
Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation
Medium Voltage (MV) & High Voltage (HV) Training Module 6 Date of the presentation Electrical System Basics MV vs. HV - Definitions Differences between USA and the rest of the world IEC define a high voltage
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
SF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical
Eaton Safety & Reliability Solutions in the Oil & Gas Industry Electrical Victor Lee Commercial Marketing Manager SEA Eaton Oil & Gas Solution Tech Day 2013 Eaton. All Rights Reserved. Eaton is a leading
Applications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
Emirates Aluminium starts up World s first fully integrated power distribution system from ABB
Reprint from Aluminium World 2009, Volume 2 Emirates Aluminium starts up World s first fully integrated power distribution system from ABB Emirates Aluminium (EMAL), a joint venture between Abu Dhabi s
GE Power Controls. MiniFORM Switchboards
GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules
Breaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
GTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
ATS - Automatic Changeover
ATS - Automatic Changeover Manufacturers of Electrical Switchgear Choosing an Automatic Transfer System Switchgear Systems offer a variety of solutions for multiple supply switching needs. As well as our
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
Engineering Specification
Engineering Specification Electrical 33KV AC INDOOR SWITCHGEAR NON-WITHDRAWABLE Owner: Approved by: Chief Engineer, Electrical Neal Hook Chief Engineer Electrical Authorised by: Version 2.1 Issued May
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
