PATENT PENDING PATENT PENDING PATENTED PATENTED
|
|
- Emma Stephens
- 7 years ago
- Views:
Transcription
1
2 2
3 3 All our services PATENT PENDING PATENT PENDING PATENTED PATENTED Saniflux Hybrid Diag Nitro Hermetic The first A/C system and passenger compartment air purification system fully integrated in a charging station. 2 services in a single station! Ecotechnics patented singlestation solution for charging standard, hybrid and electric vehicles, and vehicles with electric compressors. Integrated system for diagnosis of electromechanical problems on A/C systems, featuring printout of diagnosis and problem solutions. A/C system leak testing by charging with nitrogen from an external bottle (not included) and monitoring pressure drops, with leak alarm. Collapsible, hermetic cartridges offer full protection against ambient humidity for oil and dye, to guarantee full product efficiency.
4 4 The first air purification system integrated in an A/C charging station
5 5 Saniflux PATENT PENDING The Saniflux integrated system applies ultrasound technology (the same used in aerosols) to passenger compartment air purification and evaporator sanitising, to eliminate annoying odours and infuse a pleasant scent. With the certified Saniflux Liquid in the tank, select the service time from the station menu according to vehicle type (small, medium, large) and start treatment, which may be carried out simultaneously with A/C system charging in full automation. The passenger compartment air purification treatment uses a long hose, with a terminal drip-catcher, to permit directing the flow of nebulised product toward the evaporator, where bacteria, moulds, and other irritants and allergens may hide. The concentrated, continuous flow guarantees highlyeffective and long-lasting bactericide treatment.
6 6 Suitable for all hybrid vehicles Hybrid PATENT PENDING The new A/C systems on many latest-generation vehicles, such as hybrid or electric vehicles, are equipped with compressors operated by high-voltage electric motors containing a specific high-performance electrical insulating oil. Use of other oils may prove dangerous for the operator during system testing if high voltages are present. Preliminary flushing of the station and the service hoses is recommended before servicing a system of this type. Flushing eliminates the risk that residues of different (non-insulating) oils may be injected into the A/C system, jeopardising its safety and good operation. The patented Ecotechnics system permits running this flushing cycle automatically, thanks to the specific lateral couplings, integrated with the station, for connecting the service hoses.
7 7 Diag PATENTED The importance of patented diagnosis in recycling stations Diagnosis is an increasingly critical tool for anyone - climatecontrol specialists and not - wanting to expand their business to include A/C system repair. Ecotechnics offers the following patented solutions: 1 Static Diagnosis 2 The station uses the pressure and temperature values entered by the operator to perform automatic diagnosis. Dynamic Diagnosis With the pressure and temperature sensors A/C connected to the system, the station conducts analysis with no further need of operator intervention. The station prints a report for each type of diagnosis. ALL THE ADVANTAGES Easy to use Fast, accurate diagnosis Printout of diagnosis and list of remedial actions Reliability Perfect integration with the stations
8 8 Nitrogen leak testing Nitro The nitrogen leak testing system is an alternative to traditional leak detection methods (testing during the vacuum phase or dye injection). The advantage offered by nitrogen is that leak testing may be conducted under pressure with an inert gas. It is useful above all in those cases in which use of a dye is not permissible (for example, in automobile manufacturing). This system is fully integrated with the Ecotechnics recharging stations to eliminate the need for operator intervention during service. The system prints a leak test report at the end of testing.
9 9 Hermetic PATENTED Hermetic oil and dye cartridges An A/C station equipped with hermetic cartridges offers the advantage of eliminating contact between the humidity naturally present in ambient air and the oil or dye, which are hygroscopic substances (that is, substances that easily absorb humidity). The collapsible, accordiontype hermetic cartridges guarantee the high quality of the product charged and protect the internal components of the station from possible damage from oils and/or dyes of uncertain provenance. Moreover, many vehicle manufacturers recommend use of hermetic cartridges in their authorised repair shops.
10 10 Eck 800 Fully automatic station for recovering, recycling, and recharging R134a refrigerant. Eck 890 Type of refrigerant R134a Service procedure Fully automatic or manual Voltage 50/60 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 1 filter for humidity Vacuum pump 72 litre/min capacity, 0.1 mbar vacuum level Compressor Hermetically sealed, 12 cc, high pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 12 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 80 kg Thermal printer Optional Pressure gauges Class 1 Bottle pressure gauge Class 2.5 Display Graphic Bottle temperature sensor Integrated Bottle heater Optional
11 11 High precision Ecotechnics technology for maximum precision in recovery and recharging. Automatic Leak Testing The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm. Refrigerant Management Each service is saved in station memory, offering the option of creating a customised archive of all refrigerant transactions. Database Automobile + truck database with user option to enter new vehicle models. Graphic Display Multi-language, new generation. STANDARD FEATURES OPTIONS Thermal Printer For a complete, detailed report. Automatic Bottle Heater For fast recharging at high or low ambient temperatures. Automatic Dye Injection With refillable cartridges and electronic scale.
12 12 Eck 1000-up Fully automatic station for recovering, recycling, and recharging R134a refrigerant. SPECULARE rispetto alla foto originale Eck 1090-up Type of refrigerant R134a Service procedure Fully automatic or manual Voltage V 50/60 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 100 litre/min capacity, 0.1 mbar vacuum level Compressor Hermetically sealed, 12 cc, high pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 12 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 80 kg Thermal printer Standard equipment Pressure gauges Class 1 Bottle pressure gauge Class 2,5 Display Graphic Bottle temperature sensor Integrated Bottle heater Standard equipment
13 13 Refrigerant Management Each service is saved in station memory, offering the option of creating a customised archive of all refrigerant transactions. Thermal Printer for a complete, detailed report. STANDARD FEATURES OPTIONS Automatic Dye and Oil Injection with electronic scale and hermetic cartridges to protect the contents against contact with ambient humidity. (PATENTED) HFO UPgradable option of upgrading the charging station for use with the new HFO1234yf refrigerant, using a specific kit. Graphic Display multi-language, new generation. Diag Static diagnosis kit. Flushing kit For cleaning A/C systems by flushing with refrigerant. PATENTED PATENTED
14 14 Eck 2500-up Fully automatic station for recovering, recycling, and recharging R134a refrigerant. Eck 2900-up Type of refrigerant R134a Service procedure Fully automatic or manual Voltage V 50/60 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 100 litre/min capacity, 0.1 mbar vacuum level Compressor Hermetically sealed, 12 cc, high pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 22 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 80 kg Thermal printer Standard equipment Pressure gauges Class 1 Display Graphic Bottle temperature sensor Integrated Bottle heater Standard equipment
15 15 High precision Ecotechnics technology for maximum precision in recovery and recharging. Automatic Taps on high and low pressure lines for simpler, more practical use. STANDARD FEATURES OPTIONS Automatic Discharge of non-condensable gases via solenoid valves, with bottle temperature and pressure sensors. (PATENT PENDING) HFO UPgradable option of upgrading the charging station for use with the new HFO1234yf refrigerant, using a specific kit. Automatic Dye and Oil Injection with electronic scale and hermetic cartridges to protect the contents against contact with ambient humidity. (PATENTED) Saniflux Integrated passenger compartment air purification system. Diag Static diagnosis module. Dynamic diagnosis module. Nitro Automatic leak testing with nitrogen. Hybrid Flushing of station and service hoses for use with vehicles equipped with electric compressors. Flushing kit For cleaning A/C systems by flushing with refrigerant. PATENT PENDING PATENTED PATENT PENDING PATENTED
16 16 Fast changeover from one gas to another Protection against crosscontamination thanks to separate circuits for the 2 gases User savings Compact design, 2-in-1 station 4 pressure gauges 7 colour touch screen display Automatic discharge of non-condensable gases Automatic service taps 2 pairs of service hoses 4 separate lines for oil and dye 2 compressors Simple filter replacement High-capacity fan / air exhaust Eck twin PATENT PENDING Fully automatic Dual-Gas station for recovering, recycling, and recharging R134a and HFO1234yf refrigerants. Type of refrigerant R134a and HFO1234yf Service procedure Fully automatic or manual Voltage V - 50 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 100 litre/min capacity, 0.1 mbar vacuum level Compressor Hermetically sealed, 2x12 cc, high pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 2x12 litres, refillable Hoses 2 pairs, each 3 metres Overall size 67 x 62 x 107 cm Weight 110 kg Thermal printer Standard equipment Pressure gauges Class 1 Display Colour graphic, touch screen Bottle temperature sensor Integrated Bottle heater Automatic
17 17 Large 7 Colour Display with touch-screen icon messaging for easy use. Automatic Discharge of non-condensable gases via solenoid valves, with bottle temperature and pressure sensors. (PATENT PENDING) Automatic Leak Testing The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm. Automatic Dye and Oil Injection with electronic scale and hermetic cartridges to protect the contents against contact with ambient humidity. (PATENTED) Automatic Taps on high and low pressure lines for simpler, more practical use. STANDARD FEATURES OPTIONS Hybrid Flushing of station and service hoses for use with vehicles equipped with electric compressors. Flushing kit For cleaning A/C systems by flushing with refrigerant. PATENT PENDING PATENTED
18 18 Eck 2500-hfo Fully automatic station for recovering, recycling, and recharging HFO1234yf refrigerant. Eck 2900-hfo Type of refrigerant HFO1234yf Service procedure Fully automatic or manual Voltage V - 50 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 100 litre/min capacity, 0.1 mbar vacuum level Compressor Hermetically sealed, 12 cc, high pressure Recovery speed 300 g/min in liquid phase Refrigerant bottle 12 litres, refillable Hoses 3 metres Overall size 55 x 60 x 105 cm Weight 80 kg Thermal printer Standard equipment Pressure gauges Class 1 Display Graphic Bottle temperature sensor Integrated Bottle heater Automatic
19 19 High precision Ecotechnics technology for maximum precision in recovery and recharging. Automatic Taps on high and low pressure lines for simpler more practical use. STANDARD FEATURES OPTIONS Automatic Discharge of non-condensable gases via solenoid valves, with bottle temperature and pressure sensors. (PATENT PENDING) Automatic Leak Testing The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm. Automatic Dye and Oil Injection with electronic scale and hermetic cartridges to protect the contents against contact with ambient humidity. (PATENT PENDING) Saniflux Integrated passenger compartment air purification system. Nitro Automatic leak testing with nitrogen. Hybrid Flushing of station and service hoses for use with vehicles equipped with electric compressors. Flushing kit For cleaning A/C systems by flushing with refrigerant. PATENT PENDING PATENT PENDING PATENTED
20 20 Fully automatic station for recovering, recycling, and recharging R134a refrigerant, for use with buses and industrial vehicles. STANDARD FEATURES Automatic Leak Testing The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm. Automatic Discharge (PATENT PENDING) of non-condensable gases via solenoid valves, with bottle temperature and pressure sensors. Gear Pump for refrigerant charging. Eck bus Features identical to ECK BUS-PRO but: without gear pump with automatic bottle heater OPTIONS Type of refrigerant R134a Service procedure Fully automatic or manual Voltage V - 50/60 Hz Scale resolution 10 g Oil scale resolution 5 g Working temperature range 11/49 C Filter system 2 filters for humidity Vacuum pump 170 litre/min capacity, 0.1 mbar vacuum level Compressor Hermetically sealed, 21 cc, high pressure Gear pump 1 kg/min capacity Refrigerant bottle 40 litres, refillable Hoses 6 metres Overall size 80 x 120 x 115 cm Weight 140 kg Thermal printer Standard equipment Display LCD Pressure gauges Class 1 Flushing kit For cleaning A/C systems by flushing with refrigerant. PATENTED Eck bus-pro
21 Leak Detection Products & Consumables 21 AEK203 - Cobra kit HD Leak detector kit for A/C circuits including: goggles, UV lamp, hermetic dye cartridge (55 ml), injector AEK Box of 6 hermetic cartridges of dye (125 ml) for R134a PAG46 AEK265-6 Box of 6 hermetic cartridges of oil (270 ml) for HFO1234yf AEK203-H - COBRA KIT HD HYBRID Identical to the AEK203 but with dye cartridge for hybrid vehicles AEK Box of 6 hermetic cartridges of dye (125 ml) for HFO1234yf AEK SANIFLUX LIQUID 1000-ml bottle AEK203-C-5 - Box of 5 hermetic cartridges of dye (55 ml) AEK203-H-C-5 - Box of 5 hermetic cartridges of dye (55 ml) for hybrid vehicles AEK133-1 Box of ml cartridges AEK Electronic LEAK DETECTOR: one instrument for identifying all halogen gases, including CFC, HCFC, HFC. AEK COBRA CARTRIDGE KIT A/C circuit leak detector kit: UV lamp, goggles, 6 cartridges (7.4 ml each) of dye, injector, 120-ml bottle of dye cleaner AEK204 Oil kit for hybrid vehicles: hybrid-vehicle oil cartridge (55 ml), injector AEK Electronic leak detector for combustible gases ( ppm) ideal for nitrogen + hydrogen mix AEK145 Cobra lamp + goggles AEK204-H-5 Box of 5 hermetic cartridges of oil for hybrid vehicles (55 ml) AEK147-1 Rechargeable UV lamp: 12V, 50W AEK146 - DYE INJECTOR GUN, including dye (bottle for 64 applications), hose and coupling for R134a, high/low pressure adapter, air discharge coupling AEK Box of 6 cartridges of A/C POE oil (237 ml) AEK160 Air Fresh Spray deodorant spray AEK ml bottle of universal dye PAG46 PAG100 PAG150 AEK250-6 AEK255-6 AEK260-6 Box of 6 hermetic cartridges of oil (270 ml) for R134a AEK161 - DYE CLEANER Liquid detergent for removing dye (474 ml)
22 22 A/C Accessories XK EASYREC Refrigerant recovery unit - For use with all refrigerants - Compressor type: oilless - Air cooled - For use with gas and liquid refrigerant - Recovery rate (vapour): 17 kg/h - Recovery rate (liquid): 50 kg/h - Recovery rate (push-pull): 240 kg/h XK Easyrec plus Identical to EASYREC with carry case for R12/R134a hoses and couplings AEK302 - Electronic scale - LCD display - Max capacity: 100 kg - Resolution: 10 g - Charging accuracy: ± 10 g - Working temperature: -10 C / +50 C AEK515 - AEK525 - AEK535 Set of flexible hoses 90 cm 150 cm 180 cm CNT litre bottle for R134a, R22, R404a, R507, R407C AEK214 Rubber hose cutter AEK102-N7-R5 Set of bypass adapters for AEK 102-N12 flushing kit AEK102-N7-R6 Pair of universal bus adapter disks for AEK 102-N12 flushing kit AEK102-N7-R3 Set of 5 filters for AEK 102-N12 flushing kit AEK215 Valve-extractor screwdriver AEK120-E Digital thermometer AEK211 Special quick-connect coupling AEK303 Digital vacuum meter: micron range AEK221 Laser thermometer KITDB Data Base upgrade AEK118 Compressor vane comb AEK220 Digital thermometer with probe SCH8182 USB-RS232 adapter for downloading station data to a USB memory key TUB Low-pressure service hose, 6 m AEK116 Reducer fitting for bottle AEK109A High-pressure terminal valve TUB High-pressure service hose, 6 m + AEK116-1 ACME hose reducer fitting for bottle AEK109B Low-pressure terminal valve
23 Functions Table 23 R134a HFO1234yf R134a ECK 890 ECK 800 ECK 1090-UP ECK 1000-UP ECK 2900-UP ECK 2500-UP ECK TWIN ECK 2900-HFO ECK 2500-HFO ECK BUS-PRO ECK BUS HIGH PRECISION HFO UPGRADABLE Automatic leak check REFRIGERANT MANAGEMENT DATA BASE Graphic display LCD LCD TOUCH SCREEN DISPLAY collapsible cartridges REFILLABLE CONTAINERS AUTOMATIC TAPS AUTOMATIC Discharge of non-condensable gases 105 cm gear pump 55 cm 60 cm Flushing software USB PORT SANIFLUX HYBRID DIAG (STATIC) DIAG (DINAMIC) NITRO Printer bottle heather 122 cm AUTOMATIC DYE FLUSHING KIT KIT UP 69 cm 70 cm STANDARD EQUIPMENT Not Available Optional Information regarding dimensions, data, models, and colors is not binding. Ecotechnics reserves the right to make any modifications deemed necessary. The products are not covered by any other express or implicit warranties. 90 Kg
24 STUDIO Mirannalti Ecotechnics S.p.A Via L. Longo, 21/ Sesto F.no (FI) Tel Fax
Car and commercial cial air conditioning service solutions
Car and commercial cial air conditioning service solutions THE STANDARD IN INFORMATION AND DIAGNOSTICS SYSTEMS INTRODUCTION For the KoolKare range of vehicle air conditioning service equipment we went
More informationTools & Equipment Robinair
Tools & Accessories 2 Robinair Product overview AC RAnge Robinair is VDA and TüV approved and carries SAE-J approval. Robinair is approved by the following OEM s: 3 Robinair Moving from R134a to R1234yf
More informationKOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS
KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS h t t p : / / d i a g n o s t i c s. s n a p o n. c o. u k KOOLKARE INTRODUCTION
More informationProduct overview Air conditioning service units
Product overview Air conditioning service units 02 03 AIR CONDITIONING SERVICE UNITS FROM ROBINAIR ARE THE WORLD S MOST ADVANCED AND MOST POPULAR AIR CONDITIONING SERVICE UNITS FOR CARS; TRUCKS AND BUSSES.
More informationAC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany
AC Service Equipment ACE 21 EXPERT Fully automatic service station R-1234yf refrigerant Made in Germany The new generation of air conditioning service equipment: Robust. Environment-friendly. Fully automatic.
More informationExcellence for Professionals: Air Conditioning Service with Bosch ACS 752, 652, 611, 511, 810 and 661
Excellence for Professionals: Air Conditioning Service with Bosch ACS 752, 652, 611, 511, 810 and 661 1 A/C service from Bosch Air conditioning systems in vehicles require regular maintenance. The market
More informationPerfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651
Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651 ACS 751 and 651 A/C service unit from Bosch for R134a u ACS 751 fully automatic: Air conditioning system service for cars
More informationPrecision for Professionals: Air Conditioner Service with Bosch ACS 751, 651 and 551
Precision for Professionals: Air Conditioner Service with Bosch ACS 751, 651 and 551 ACS 751, 651 and 551 A/C service unit from Bosch for R134a u ACS 751 fully automatic: Air-conditioning system service
More informationFully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop
Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop ACS 600, 601, 650: Air conditioning service units from Bosch u ACS 600 even the entry model is fully automatic u ACS
More informationExcellence for Professionals: Air Conditioner Service with Bosch ACS 752, 652, 611, 511, 810 and 661
Excellence for Professionals: Air Conditioner Service with Bosch ACS 752, 652, 611, 511, 810 and 661 1 A/C service from Bosch Air conditioning systems in vehicles require regular maintenance. The market
More informationFully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop
Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Prüftechnik ACS 600, 601, 650 Air conditioning service units from Bosch NEW! Ñ ACS 600 even the entry model is fully
More informationRefrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
More informationRefrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale
More informationAir conditioning service unit CAAS500
Air conditioning service unit CAAS500 OPERATING INSTRUCTIONS TES1453 09/2004 C A A S 5 0 0 O P E R A T I N G I N S T R U C T I O N S P a g e 2 IMPORTANT THIS MANUAL CONTAINS INFORMATION PERTINENT TO OPERATOR
More informationRefrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants
More informationRefrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507 Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale changeover of HCFCs
More informationElements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system
AURETU004 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system 2. Diagnose air conditioning and
More informationORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
More informationSubject: 2005 Air Conditioning Service Guidelines
Date: June 27, 2005 Bulletin Number: 05D-J-114 To: DDG Headquarters and Branches and Jobbers Category: Service From: Steve Sigg, Product Service and Training Line(s): 10 and 15 Subject: 2005 Air Conditioning
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationHIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
More informationMeasurement Solutions for Refrigeration Technology.
Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. Testo refrigeration technology Digital is better: Refrigeration technology expertise
More informationSERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
More informationAutomotive Air-Conditioning Service Equipment Ariazone 5001 OPERATOR MANUAL Ariazone 5001
Automotive Air-Conditioning Service Equipment Ariazone 5001 OPERATOR MANUAL Ariazone 5001 - Automotive A/C Service Station 1 Contents Page 1. Introduction... 3 2. Safety firts... 4 3. Technical Features...
More informationAir Conditioning Workshop Equipment 2013 / 2014
waeco AirCon Service Air Conditioning Workshop Equipment 2013 / 2014 Low Emission From Europe s No. 1 in A/C service A/C service units for and R 1234yf Fully automatic A/C service Refrigerants, oils and
More informationAIR CONDITIONING COMPRESSOR OIL
AIR CONDITIONING COMPRESSOR OIL PAG, PAO and POE oils AIR CONDITIONING COMPRESSOR OIL THERE ARE LOTS OF OILS AVAILABLE, WHICH ONE IS RECOMMENDED? Oil plays an important role in the air conditioning system:
More informationAir Conditioning Service Tools & Equipment
27/04/12 G2 R-410A Service Manifold & Gauges (BlackMax ) Exclusive TripleSeal valve system Valve stems retract fully for maximum flow Back seating o-ring seals valve nut when fully open Aluminum block
More informationR407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C
GUIDELINES FOR UTILIZATION OF R407C 2009 Tecumseh Products Company. All rights reserved. Page 1 of 6 After many years of testing and investigation, R407C is recognized as a suitable alternative refrigerant
More informationTraining Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test
APTA STANDARDS DEVELOPMENT PROGRAM RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA BTS-BMT-RP-001-10 Approved October, 2010 APTA Bus Maintenance
More informationThis equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series
MOBILE REFRIGERANT RECOVERY/RECYCLING SYSTEM MODELS AR500 AR512 SERIES TO BE OPERATED BY QUALIFIED PERSONNEL ONLY! This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for
More informationROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
More informationHow To Use An Irius Pid Detector
SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use
More informationMAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
More informationTable of Contents. First Aid for Refrigerant Exposure 35. First Aid for Skin Exposure / First Aid for Eye. Chapter 3:
Table of Contents Chapter 1: Introduction to Automotive Heating, Air Conditioning, and Ventilation 11 Heating, Ventilating, and Air Conditioning (HVAC) Systems 12 Why Is It Called HVAC? Major Heating,
More informationR-134A A/C SYSTEM REFRIGERANT DYE LEAK DETECTION
Classification: Reference: Date: HA99-001a NTB99-011a May 27, 1999 R-134A A/C SYSTEM REFRIGERANT DYE LEAK DETECTION This amended version of NTB99-011 adds "Claims Information" regarding the use of a specific
More informationVisions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationAir Conditioning Workshop Equipment
WAECO A/C service units Leak detection equipment Measuring instruments Air conditioner cleaning Tools Consumables Refrigerants Oils Battery jump starter Air Conditioning Workshop Equipment With products
More informationSYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List
More informationTools & Instruments. Totaline P920-RECOVERY115 Oil-Less Refrigerant Recovery Unit
Totaline P920-RECOVERY115 Oil-Less Refrigerant Recovery Unit Recovery Rates - Per ARI 740 Standard P920-RECOVERY115 R22 R410a R134a R407c Push/Pull Liquid 13.60lbs/min. 13.99bs/min. 10.58bs/min. 13.75bs/min.
More informationHeating and Air Conditioning
Heating and Air Conditioning S Y L L A B U S Your Course Learning Plan UAWLETC EK 4-13-06 A. General Course Information Course description: The Heating and Air Conditioning students of UAW-LETC will successfully
More informationDiagram of components 2. Reducer..3
Index Diagram of components 2 Reducer..3 Rail Filter - Rail Filter 4 - MAP Sensor.4 Injector & Nozzle - Single Injector / Rail Injector...5 - Bi-Fuel Connector...6 - Nozzle...7 ECU...8 Switch 9 Wiring
More informationMIDLAND COLLEGE SYLLABUS DEMR 1323 AUTOMOTIVE HEATING AND AIR CONDITIONING 2-4
Course Description: Text, References and Supplies: Course Goals/Objectives: Theory of automotive air conditioning and heating systems. Emphasis on the basic refrigeration cycle and diagnosis and repair
More informationhttp://www.smartpdfcreator.com
Technical Service Bulletin Transaction No.: 2018162/2 87 Cleaning of the air conditioning refrigerant circuit Release date: Dec 5, 2008 Condition REVISION HISTORY Revision Date Purpose 2 - Revised Title
More informationRS-24 (R426A): Q & A
RS-24 (R426A): Q & A 1 Q: What is RS-24? A: RS-24 is a non ozone depleting Drop-in replacement for R12 in all applications including mobile air conditioning. 2 Q: Yes, but what does RS-24 contain? A: RS-24
More informationOperations and Maintenance Manual
Operations and Maintenance Manual FOR MODELS 1234XL 1090XL 1095XL P/N 99971-SP Rev. 1/98 Table of Contents Set-Up...1 Introduction... 1 Unit Set-Up... 1 White Industries Models...1 1090XL Panel and 1234XL
More informationSYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.
SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING Effective From :- UNDER DEVELOPMENT Prepared by: Curriculum development cell Institute of Research Development
More informationThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
More informationMINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE
MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE Faculty are required to have the outline submitted to the Academic Affairs Office. The course outline is the form used for approval of new courses
More informationFlushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
More informationInformation on New Refrigerant (R-1234yf) for A/C Service
Information on New Refrigerant (R-1234yf) for A/C Service 2013 Cadillac ATS, XTS This bulletin is being revised to include procurement and labeling information for recovery cylinders to be used with GE-50957-Contaminated
More information2014 / 2015 AIR CONDITIONING WORKSHOP EQUIPMENT LOW EMISSION FAST, ECONOMICAL, ECO-FRIENDLY A/C SERVICE UNITS FOR R 134A AND R 1234YF
WAECO AirCon Service AIR CONDITIONING WORKSHOP EQUIPMENT 2014 / 2015 LOW EMISSION FAST, ECONOMICAL, ECO-FRIENDLY YEARS A/C service units Refrigerants and oils A/C flushing Recovery/leak detection Air conditioner
More informationA Practical Guide to Free Energy Devices
A Practical Guide to Free Energy Devices Part PatE17: Last updated: 24th November 2006 Author: Patrick J. Kelly This is a patent application from Stephen Meyer, brother of the late Stan Meyer. While this
More informationAddendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals
Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals HVAC PROGRAMS The school s Heating, Ventilation, and Air Conditioning Programs provide training for entry level employment
More informationOperating Manual for Model 34988. Recovery, Recycling, Recharging Unit
Operating Manual for Model 34988 Recovery, Recycling, Recharging Unit Model 34988 Recovery, Recycling, & Recharging Unit SAFETY DEFINITIONS: Follow all WARNING, CAUTION, and NOTE messages in this manual.
More informationCOOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
More informationFederal Clean Air Act Section 609 Training Manual & Exam
Federal Clean Air Act Section 609 Training Manual & Exam Table of Contents INTRODUCTION... Who Must Be Certified... Training and Certification... Test Format... Test Administration and Grading... i STRATOSPERIC
More informationElements Elements describe the essential outcomes.
AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes
More informationVehicle Air Conditioning Service Equipment, Technical Training, Tools and Consumables Catalogue
Vehicle Air Conditioning Service Equipment, Technical Training, Tools and Consumables Catalogue Cooling Edge has endeavoured to ensure that the information provided in this catalogue to be true and correct
More informationQingdao Guihe Measurement&Control Technology Co., Ltd. Automatic Tank Gauging System, Magnetostrictive Diesel fuel tank level gauge
Automatic Tank Gauging System Magnetostrictive Liquid Level Meter (Tank gauging system) for gas stations produced by Guihe consists of Probe and Touch Control Console. There are different plans to satisfy
More informationMAHLE Aftermarket now also offers Behr HVAC service units.
Our service for your service MAHLE Aftermarket now also offers Behr HVAC service units. MAHLE Aftermarket and Behr Service a partnership for a healthy atmosphere Behr has many years of development expertise
More informationGuidance for Stationary Refrigeration & Air-Conditioning
Information Sheet RAC 3 Key Obligations Guidance for Stationary Refrigeration & Air-Conditioning This Information Sheet provides a description of the key obligations under the EC F gas and Ozone Regulations
More informationFreezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
More informationADU 5. Automatic Distillation Unit
ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement
More informationTECHNICAL INFORMATION
1- INTRODUCTION The destruction of the ozone layer by the chlorofluorcarbons (CFC s), among which are CFC 11, CFC 12, and CFC 13 and its vital effect on the earth's ecosystem, were the principal reasons
More informationDruck PV 62x pneumatic/hydraulic pressure stations
GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300
More informationON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
More informationModel ATD-36750 Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends
Model ATD-36750 Refrigerant Gas Leak Detector Detects all CFC, HFC, HCFC, HFO Refrigerants including blends User Manual Design certified by ASCI and Intertek to meet SAE J2791, J2913 & EN14624 INTRODUCTION
More informationGuide to good leak testing
Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant
More informationCOMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A
COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A (All unshaded skill sets must be demonstrated/completed) PROTECT SELF AND OTHERS Identify, interpret, and
More informationOT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
More informationThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems
More informationVALUE-100 A/C Service Station User s Manual INDEX
INDEX INTRODUCTION...1 CARE OF THE MANUAL...1 WARRANTY...1 GENERAL INFORMATION...2 END-OF-LIFE...2 SAFETY RULES...2 PRECAUTIONS FOR HANDLING AND USE OF REFRIGERANT FLUIDS...3 PRINCIPLES OF OPERATION...3
More informationKNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
More informationThe Fastest Breaking Fogging Systems
FBF SYSTEMS The Fastest Breaking Fogging Systems INTRODUCTION Fogging systems are the real new solution to stop burglars or avoid a robbery. They work as a siren but, instead of emitting a sound, they
More informationCompact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details!
Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details! Air. CompressedAir. BogeAir. Now you can! CM compact module 2.2 7.5 kw Effective free air delivery:
More informationMACHINES FOR REFRIGERATION AND AIR CONDITIONING
00 MA0900 MACHINES FOR REFRIGERATION AND AIR CONDITIONING The widespread use of air conditioning systems, both civil and industrial, in order to increase the comfort at work and at home, as well as the
More informationA/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
More informationRecommended Compressor Installation Practices
ASPEN COMPRESSOR, LLC Phone: 508.481.5058 Fax: 508.480.0328 Email:info@aspencompressor.com Website: www.aspencompressor.com Recommended Compressor Installation Practices 1. COMPRESSOR SELECTION AND USE
More informationwww.hft-global.com/education Refrigeration & HVAC
www.hft-global.com/education The HFT Refrigeration and HVAC range has been designed and developed to allow study of the theoretical and practical operation of many types of refrigeration and air conditioning
More informationGENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).
GENERAL INFMATION F REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ). Name of sector Refrigeration & Air Conditioning Name of Module REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationDLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw
DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel
More informationAUTOMOTIVE AIR CONDITIONING
3rd Edition 3rd Edition Resources available For the instructor Register online at: www.cengagebrain.com for the study tools that come with your textbook! Companion website: includes weblinks and downloadable
More informationRecharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
More informationROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw
ROTARY SCREW COMPRESSOR RMD - - - 55 kw EN The RMD Coaxial Rotary Compressor high reliability high performance low maintenance is the result of decades of experience in manufacturing design and construction
More informationTraining Manual SUPER SEAL. Simplifying AC/R Repair. Inside Your Guide PROFESSIONAL FORMULA. www.cliplight.com/hvacr/ Page 2 3 4 4 5 6 8 9
SUPER SEAL PROFESSIONAL FORMULA Training Manual a. b. c. d. e. f. g. h. i. j. k. l. m. Inside Your Guide Frequently Asked Questions... How does Super Seal work?... Can you use Super Seal on 410a systems
More informationRefrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-502 to R-402A/R-408A Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale CFC changeover of CFC HCFC
More informationINSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
More informationThe photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
More informationREFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016. Information compiled by Frank Prah, CMS
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 REFRIGERANT 410A Information compiled by Frank Prah, CMS INTRODUCTION Recently a new refrigerant, R-410A, has been formulated
More informationHEATER, AIR CONDITIONER AND VENTILATION <MANUAL A/C>
HEATER, AIR CONDITIONER AND VENTILATION Click on the applicable bookmark to selected the required model year. 55A-2 HEATER, AIR CONDITIONER AND VENTILATION CONTENTS SERVICE SPECIFICATIONS...
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationitaltec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
More informationGround-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29
Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont
More information2. AIRCONDITIONING AND REFRIGERATION
2. AIRCONDITIONING AND REFRIGERATION 1. INTRODUCTION Air Conditioning and Refrigeration is an important area where in lot of self-employment opportunities are available. Now a day there is hardly a house
More informationHybrid Air Conditioning Systems Overview
Southern Illinois University Carbondale OpenSIUC Presentations Department of Automotive Technology Spring 2011 Hybrid Air Conditioning Systems Overview Eugene Talley Southern Illinois University Carbondale,
More informationHEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
More information