RS-24 (R426A): Q & A
|
|
|
- Hilary Thomas
- 9 years ago
- Views:
Transcription
1 RS-24 (R426A): Q & A 1 Q: What is RS-24? A: RS-24 is a non ozone depleting Drop-in replacement for R12 in all applications including mobile air conditioning. 2 Q: Yes, but what does RS-24 contain? A: RS-24 is a blend of HFC134a, HFC125, butane and isopentane. 3 Q: Does RS-24 have an ASHRAE number & what is its classification? A: Yes. RS-24 has been designated an ASHRAE number of R426A with a classification of A1, which is low toxicity & non flammable under all conditions of fractionation. 4. Q: Is RS-24 subject to a phase out programme under any regulations as is the case with CFCs and HCFCs? A: No. None of the components of RS-24 is subject to a phase out schedule under the Montreal protocol or any regulations. 5 Q: Why is RS-24 different to Isceon 49 (MO49)? A: RS-24 does not contain perfluorocarbon 218, which has an atmospheric lifetime of over 2,500 years and is a significant constituent of Isceon 49. RS-24 s lifetime in the atmosphere is less than 20 years compared to approximately 250 years in the case of 49 on a weight average basis. RS-24 is non flammable with an ASHRAE classification of A1 while Isceon 49 (MO49) is classified A2. RS-24 also has a lower head pressure than Isceon Q: How does RS-24 compare to other Drop-in refrigerants such as R409A (FX56), R401A (MP39) and others? A: RS-24 in the first place has no ability to deplete ozone which R409A and R401A have and as such RS-24 is a long term replacement for R12. In addition, RS-24 is suitable for automobile air conditioning applications which is not the case with R409A and R401A, or any other mixtures containing R22. 7 Q: Is RS-24 suitable for mobile air conditioning? A: Yes. RS-24 can be used in this application without the need to change the oil thereby enabling the continued use of traditional mineral oils. 8 Q: Can RS-24 be used with mineral and alkylbenzene lubricants? A: Yes. There is no need to change to synthetic POE or PAG oils with RS-24 which operates satisfactorily with traditional lubricants.
2 2 9 Q: Is RS-24 non flammable and non toxic? A; RS-24 is both non flammable and non toxic. RS-24 is non flammable as defined by the ASHRAE EN test. 10 Q: Is RS-24 approved by compressor manufacturers? A: The individual components which comprise RS-24 are widely used in compressors produced by major manufacturers. 11 Q: Can RS-24 be used to top up a system containing R134a and POE or PAG oil? A: Yes. The components of RS-24 are compatible with R134a and synthetic lubricants. 12 Q: When RS-24 has been used to top up a system originally charged with R134a and a synthetic lubricant, which type of lubricant should be added? A: The original synthetic lubricant should be added to the system. 13 Q: Can RS-24 be used to top up a system originally charged with R12? A: No. Such a mixture can produce extremely high pressures due to the formation of a R12/R134a azeotrope. 14 Q: Can RS-24 be added to Isceon 49? A: There is not sufficient experience in the field to be able to comment. It is recommended that Isceon 49 is recovered from the system and replaced with RS Q: Can RS-24 be added to R409A (FX56) or any other drop-in R12 replacement? A: No. RS-24 is a very different refrigerant and should not be mixed with R409A or other drop-in replacements. 16 Q: Is RS-24 as efficient as R12 or R134a? A: RS-24 s efficiency is comparable to both R12 and R134a. 17 Q: What tests have been carried out on RS-24 and what are the results? A: Tests on RS-24 have been carried out in commercial refrigeration, domestic appliances and mobile air conditioning. The results show good oil return to the compressor in all cases and a level of efficiency similar to both R12 and R134a. 18 Q: Does RS-24 need to be charged in the liquid or gaseous form? A: Because RS-24 is a blend, the recommendation is to charge it into the system in the liquid form. However, if the entire contents of the cylinder are being charged, then vapour charging is acceptable.
3 3 19 Q: Does the RS-24 disposable cylinder have a dip tube? A: No. The disposable should be inverted to discharge RS-24 in the liquid form. 20 Q: Is RS-24 on the SNAP (Significant New Alternatives Policy programme) list in the USA? A: Yes. RS-24 is on the SNAP list and approved by EPA for all uses where R12 finds an application.. 21 Q: How does RS-24 s pressure rating compare with R12 and R134a? A: RS-24 s discharge pressure is very similar to R134a. 22 Q: How does RS-24 s capacity compare to R12? A: RS-24 s capacity is very similar to R Q: How does RS-24 s capacity compare to R134a? A: RS-24 s capacity is slightly higher than to R134a. 24 Q: How does RS-24 s temperature rating compare to R12? A: RS-24 s discharge temperatures are lower than R Q: How does RS-24 s temperature rating compare to R134a? A: RS-24 s discharge temperatures are similar to R134a. 26 Q: What are the flammability characteristics of RS-24? A: RS-24 is non flammable at room temperature and atmospheric pressure, and has the same classification as R12, R134a, R404A, R409A (FX56), R507 (AZ-50) etc 27 Q: What are the decomposition products resulting from the combustion of RS-24? A: The decomposition products resulting from subjecting RS-24 to a high temperature source are similar to those when R12 and R134a are exposed to fire conditions. The decomposition products in each case are irritating and toxic, and breathing apparatus should be worn where a possibility to exposure exists 28 Q: Are there any special precautions with RS-24? A: There are no specific precautions which must be taken with RS-24. As with all refrigerants, common sense and good housekeeping is always recommended. Because the use of hygroscopic synthetic POE lubricants are avoided with RS-24, scrupulous attention to preventing moisture contamination is not necessary, although the ingress of moisture should be avoided at all times.
4 4 29 Q: Is RS-24 compatible with refrigeration and air conditioning systems designed for R12? A: Yes. RS-24 is compatible with all materials commonly used in systems that were designed and charged with R12. As in the case of R12, magnesium and zinc alloys should be avoided. 30 Q: Can RS-24 be recovered and recycled like other R12 alternatives? A: Yes. RS-24 can be recovered and re-used like other R12 alternatives after a cleaning process such as reclamation. 31 Q: What technical guidance do you advise when changing from R12 to RS-24? A: The procedure for converting from R12 to RS-24 is very similar to any other conversion to a Drop-in replacement. Use the same type of lubricant, replace the filter/drier and charge approximately 10% less RS-24 than the original R12 charge after fully evacuating. 32 Q: How does RS-24 compare in price with R134a and other alternatives? A: RS-24 is competitive in price with other R12 alternatives. 33 Q: What is the main advantage of RS-24? A: RS-24 is a long term alternative for R12, and its main advantage is that it can be used to replace R12 without the need to change the original mineral oil in the system. There is, therefore, no necessity to retrofit to a synthetic lubricant (polyolester or polyalkylene glycol). 34 Q: Why should RS-24 be used in mobile air conditioning when the addition of R134a and synthetic lubricants to the system without draining the mineral oil appears to work satisfactorily? A: It is widely accepted that R134a alone is not miscible in mineral oil which should be reduced to a maximum 5% content before adding a synthetic lubricant. RS-24 can be used with both mineral and synthetic lubricants which removes the risk of not achieving oil return to the compressor. 35 Q: Can RS-24 be used in flooded evaporators? A: Because RS-24 has a very low glide of less than 1 0 C, RS-24 is suitable for use in flooded evaporators. 36 Q: Can RS-24 be used satisfactorily at evaporator temperatures below 20 o C?
5 5 A: Under certain circumstances, at low evaporator temperatures, poor oil miscibility can result in problems with compressor lubrication. At evaporator temperatures below -20 o C, migration of oil to the evaporator can result in a lack of lubrication in the compressor. If such conditions apply, then the recommendation is to change to a polyol ester lubricant to facilitate oil return to the compressor. There is no need to drain all the existing oil from the system. Simply remove as much of the mineral oil charge as is practicable and recharge to the appropriate level using POE lubricant. 37 Q: Are there any problems of oil migration using RS-24 if a flooded start-up occurs? A: Under some circumstances flooded start-ups can occur when the non-operating compressor of a refrigerated vehicle is exposed to a lower temperature than that of the evaporator, and this temperature differential can result in refrigerant condensing in the compressor sump. In the case of R12, the refrigerant will dissolve in the mineral oil. RS-24, being less miscible with mineral oil, can collect as a pool in the bottom of the sump where the outlet to the oil pump is typically sited. When the compressor is next started, oil flow to the bearings could be impeded. It has long been recognised that flooded start-ups are detrimental to compressor operation. Even in R12 systems, designers sometimes anticipate excessive wear by fitting heaters which prevents the problem. In many cases, a pressure controlled check valve is installed between the evaporator and compressor to prevent the return of the condensed liquid refrigerant to the sump. Where sump heaters are fitted, they will prevent the accumulation of liquid of RS-24. Indeed, they might be even more effective in this case since less heat is required to evaporate a liquid refrigerant than to distil a refrigerant from a solution. If the possibility of a flooded start-up exists, then the recommendation is to change to a polyol ester lubricant, which will increase the miscibility of the refrigerant with the lubricant thereby facilitating oil return to the compressor and also avoid accumulation of lubricant in the evaporator. 38 Q: Is RS-24 compatible with hoses, seals, gaskets and O-rings commonly used with R12? A: RS-24 is compatible with all materials commonly used in refrigeration systems previously charged with R12.In general, materials which are compatible with R12 can be used with RS-24. It is recommended to check equipment manufacturer's retrofit literature and obtain recommendations from equipment manufacturers with regard to materials' compatibility. In older systems which have been operating on R12 for many years, replacement of some seals may be required due to the different composition of RS-24 which contains HFCs.Yes. Because the original mineral oil is being used and not a synthetic lubricant, elastomers and plastics used with R12 are compatible with RS Q: How does the Coefficient of Performance (COP) of RS-24 compare with R12 and R134a?
6 6 A: The COP of RS-24 is slightly lower than R12 and R134a and slightly higher than R409A (FX56). 40 Q: What is the specification for RS-24? A: RS-24 complies with the refrigerant specification ARI for fluorocarbon refrigerants. 41 Q: What is the effect of high exposures by inhalation of RS-24? A: As is the case with all CFC, HCFC and HFC based refrigerants, high exposure to RS-24 may produce anaesthetic effects. Very high exposures may cause an abnormal heart rhythm and prove suddenly fatal as is the case with all CFC, HCFC and HFC based refrigerants. 42 Q: What is the flash point, flammability explosion limits and auto-ignition temperature for RS-24? A: RS-24 is non flammable as defined in the ASHRAE EN test, and hence does not have a flash point or explosion limits. The auto-ignition temperature of RS- 24 has not been determined but is expected to be greater than 750 o C. 43 Q: What type of leak detectors should be used with RS-24? A: Leak detectors designed for HFCs, eg R134a, R404A, R507, R407C etc, are suitable for use with RS Q: Can RS-24 be used in a system designed and initially charged with a hydrocarbon, ie R600a iso-butane? A: Yes. 1/2/06
RS-44 (R424A) : Q & A
RS-44 (R424A) : Q & A 1 Q: What is RS-44? A: RS-44 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-44 contain? A: RS-44 is a blend of HFC134a, HFC125,
RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight 107.5 111.6 Temperature glide o C 0.5 0.2 Boiling point (1 atm)
RS-52 (R428A) COMPOSITION % HFC 125 77.5 HFC 143a 20.0 R600a 1.9 R290 0.6 HCFC replacement Temperature glide R22, 502 & interim blends Approximately 0.8 o C Drop-in or long term Both Lubricant MO/AB/POE
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C
GUIDELINES FOR UTILIZATION OF R407C 2009 Tecumseh Products Company. All rights reserved. Page 1 of 6 After many years of testing and investigation, R407C is recognized as a suitable alternative refrigerant
THE REPLACEMENT OF R-22
ENGLISH TRANSLATION OF ARTICLE IN FRIO-CALOR AIRE ACONDICIONDAO BY GAS-SERVEI, S.A JUNE 2010 THE REPLACEMENT OF R-22 Courtesy of D. Lluis Giralt Lopez (Chemical Engineering Industrial) Gas Technical Department
REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016. Information compiled by Frank Prah, CMS
Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 REFRIGERANT 410A Information compiled by Frank Prah, CMS INTRODUCTION Recently a new refrigerant, R-410A, has been formulated
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems Dr. Charles C. Allgood 1, C. Curtis Lawson 2 1 DuPont Fluorochemicals, Wilmington, DE, USA E-mail: [email protected]
Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment
Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment Brett Van Horn Market Manager HVAC Arkema Inc. 900 First Ave King of Prussia, PA 19406 Topics Covered Today R-22 Phase-out EPA Allowances
REFRIGERANT REFERENCE GUIDE
REFRIGERANT REFERENCE GUIDE WORLWIDE REFRIGERANT SUPPLIER 2004 FOURTH EDITION 2004 DISCLAIMER This publication is designed to provide accurate and authoritative information. It is not to be construed as
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants
Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale
Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507 Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale changeover of HCFCs
Part A: Fluid properties
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material on HFC for management: HFC Workshop, technical 2015 issues Bangkok, 20 and 21 April 2015 FACT SHEET 15 Glossary of terms and technical
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 21 Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
It s Your Choice Retrofitting Your Car s A/C System 1EPA. 2 Printed on paper that contains at least 20 percent postconsumer fiber.
United States EPA430-F-97-052 Environmental Protection June 1997 Agency 1EPA Air and Radiation (6205J) It s Your Choice Retrofitting Your Car s A/C System 2 Printed on paper that contains at least 20 percent
refrigerants DuPont Suva 134a (HFC-134a) for Mobile Air Conditioning Technical Information Introduction Transition to HFC-134a
Technical Information DuPont Suva refrigerants Note: This publication supersedes Bulletin ART-12. ART-27 DuPont Suva 134a (HFC-134a) for Mobile Air Conditioning Introduction In the past almost all mobile
Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-502 to R-402A/R-408A Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale CFC changeover of CFC HCFC
Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume 40 2. Refrigerant History
providing insights for today s hvac system designer Engineers Newsletter volume 40 2 HVAC Refrigerants: A Balanced Approach One of the constant themes throughout the history of the HVAC industry is the
The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out
Information Sheet RAC 8 R22 Phase-out The EC Ozone Regulation Legislative Update and Strategies for HCFC Phase-out 1. Background to HCFC Phase Out The EC Ozone Regulation (EC/2037/2000) provides the legislative
SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)
Form #SB4-304AS AirSourceR SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION) Second only to refrigerant hose leaks, compressors have the highest rate
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems William M. Corcoran, George Rusch, Mark W. Spatz, and Tim Vink AlliedSignal, Inc. ABSTRACT
Refrigerants for Residential and Commercial Air Conditioning Applications
Refrigerants for Residential and Commercial Air Conditioning Applications October 2008 Table of contents Executive summary 2 Introduction and background 3 Environmental drivers 4 Regulatory update 8 Criteria
Table of Contents. First Aid for Refrigerant Exposure 35. First Aid for Skin Exposure / First Aid for Eye. Chapter 3:
Table of Contents Chapter 1: Introduction to Automotive Heating, Air Conditioning, and Ventilation 11 Heating, Ventilating, and Air Conditioning (HVAC) Systems 12 Why Is It Called HVAC? Major Heating,
Patech. Our Conviction. Quality Service Innovation PATECH FINE CHEMICALS CO., LTD
Our Conviction Quality Service Innovation Product Categories Refrigeration Lubricants POE for HFC Refrigerants POE for HCFC Refrigerants POE for HFO Refrigerants Special Plasticizers Nontoxic Plasticizer
COMPRESSOR REPLACEMENT PROCEDURE
R-22 and R-410A COMPRESSOR REPLACEMENT PROCEDURE Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned Manual No.: 2100-003F Supersedes 2100-003E File: Volume I,
Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity
Technical Note: Comparing R407C and R410A as Alternatives for R22 A Technical Note from the Experts in Business-Critical Continuity Purpose The purpose of this document is to provide a brief overview of
Subject: 2005 Air Conditioning Service Guidelines
Date: June 27, 2005 Bulletin Number: 05D-J-114 To: DDG Headquarters and Branches and Jobbers Category: Service From: Steve Sigg, Product Service and Training Line(s): 10 and 15 Subject: 2005 Air Conditioning
Flushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
EPA 608 Certification. Study Guide. 1 P a g e
EPA 608 Certification Study Guide 1 P a g e Foreword All HVACR technicians must become certified for the equipment they work on, under the Environmental Protection Agency s (EPA), refrigerant recovery
Elements Elements describe the essential outcomes.
AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes
TECHNICAL INFORMATION
1- INTRODUCTION The destruction of the ozone layer by the chlorofluorcarbons (CFC s), among which are CFC 11, CFC 12, and CFC 13 and its vital effect on the earth's ecosystem, were the principal reasons
Recommended Compressor Installation Practices
ASPEN COMPRESSOR, LLC Phone: 508.481.5058 Fax: 508.480.0328 Email:[email protected] Website: www.aspencompressor.com Recommended Compressor Installation Practices 1. COMPRESSOR SELECTION AND USE
HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22
HCFC-22 Retrofits A c l o s e l o o k a t t h e r e f r i g e r a n t / l u b r i c a n t i n t e r a c t i o n s. B y S a m u e l F. Y a n a M o t t a, E l i z a b e t D. V e r a B e c e r r a, R o n
Guidance for Stationary Refrigeration & Air- Conditioning
Department for Environment, Food and Rural Affairs Guidance for Stationary Refrigeration & Air- Conditioning The EU Ozone Regulation: Legislative update and strategies for HCFC Phase-out Information Sheet
Planning for the ban on R22 in building air conditioning
- ACHPI 32 Planning for the ban on R22 in building air conditioning Those responsible for cooling and heating commercial properties are under increased pressure to improve energy efficiency and negotiate
Automobile Air Conditioning Primer
Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the
Refrigerant handling code of practice 2007
Australia and New Zealand Refrigerant handling code of practice 2007 Part 1 Self-contained low charge systems Prepared by the Australian Institute of Refrigeration, Air Conditioning and Heating (AIRAH)
Heating and Air Conditioning
Heating and Air Conditioning S Y L L A B U S Your Course Learning Plan UAWLETC EK 4-13-06 A. General Course Information Course description: The Heating and Air Conditioning students of UAW-LETC will successfully
The phase out of R22. Phase out of HCFCs
The phase out of R22 The Montreal Protocol on Substances that Deplete the Ozone Layer is widely regarded as the world s most successful environment protection agreement. It is the only treaty with universal
Federal Clean Air Act Section 609 Training Manual & Exam
Federal Clean Air Act Section 609 Training Manual & Exam Table of Contents INTRODUCTION... Who Must Be Certified... Training and Certification... Test Format... Test Administration and Grading... i STRATOSPERIC
Mohan Chandrasekharan #1
International Journal of Students Research in Technology & Management Exergy Analysis of Vapor Compression Refrigeration System Using R12 and R134a as Refrigerants Mohan Chandrasekharan #1 # Department
RETROFITTING WITH NON-CFC SUBSTITUTES
INFORMATION PAPER RETROFITTING WITH NON-CFC SUBSTITUTES September 1994 OzonAction Information Clearinghouse OzonAction Programme Industry and Environment DISCLAIMER This preliminary document is provided
MATERIAL SAFETY DATA SHEET - Air-Compressed
1. PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: CHEMICAL NAME: CHEMICAL FAMILY: SYNONYMS: CHEMICAL FORMULA: USE: NAME AND ADDRESS: Air, compressed Air Nonflammable gas Medical Air, Breathing Air, Compressed
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential
International Journal of Scientific and Research Publications, Volume 2, Issue 9, September 2012 1 A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of
Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29
Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT) MAINTENANCE TYPE: STATUTORY 1.0 SCOPE OF SERVICES The Contractor shall provide maintenance Services for
Refrigerant identification and equipment issues in relation to HCFC phase-out. Ole Reinholdt Nielsen
Refrigerant identification and equipment issues in relation to HCFC phase-out Ole Reinholdt Nielsen Belize, March 3, 2010 Outline Brief introduction; Refrigerant identification: Historically; Options for
Aluminium as Construction Material in Ammonia Refrigeration Cycles
Aluminium as Construction Material in Ammonia Refrigeration Cycles Experiences With Aluminium Compared to other metals, aluminium has only a brief history as an engineering material. While, about 150 years
Low GWP Replacements for R404A in Commercial Refrigeration Applications
Low GWP Replacements for R404A in Commercial Refrigeration Applications Samuel YANA MOTTA, Mark SPATZ Honeywell International, 20 Peabody Street, Buffalo, NY 14210, [email protected] Abstract
USC CFC Leak Repair and Recordkeeping Procedures
USC CFC Leak Repair and Recordkeeping Procedures I. Introduction Chlorofluorocarbons (CFCs) released into the atmosphere can damage the ozone layer that protects the earth from the penetration of harmful
: GLADE Aerosol - Lavender
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING Product information Product identifier : Relevant identified uses of the substance or mixture and uses advised against : Air Freshener
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Types : ASHRAE Refrigerant number designation: R-507
This SDS adheres to the standards and regulatory requirements of the European Community and may not meet the regulatory requirements of other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND
HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY
HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY The impact of refrigeration
DuPont SUVA 123 Refrigerant
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
Refrigeration and Air Conditioning with Reduced Environmental Impact
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Refrigeration and Air Conditioning with Reduced Environmental Impact D.
01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
Guide to updated EU f-gas regulation (517/2014).
Guide to updated EU f-gas regulation (517/2014). Date July 2014 02 Contents Contents. 03 Introduction 04 F-gas regulation update: key changes 05 Regulation structure 06 Product and equipment bans 09 Service
PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A
Int. J. Mech. Eng. & Rob. Res. 213 Jyoti Soni and R C Gupta, 213 Research Paper ISSN 2278 149 www.ijmerr.com Vol. 2, No. 1, January 213 213 IJMERR. All Rights Reserved PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION
TRAINING, EXAMINATION AND CERTIFICATION
TECHNICAL STANDARDS & SAFETY AUTHORITY TRAINING, EXAMINATION AND CERTIFICATION REFRIGERATION OPERATOR CLASS B CERTIFICATION & EXAMINATION GUIDE REVISED EDITION 2 CERTIFICATIONS PERSUANT TO THE OPERATING
Certification Training Manual
Revised 12/2008 Certification Training Manual Including: Refrigerant Recycling and Service Procedures for Mobile Air Conditioning Technicians Best Service Practices Approved by the U.S. EPA for technician
THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A
THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A Jignesh K. Vaghela Assistant Professor, Mechanical Engineering Department, SVMIT, Bharuch-392001, (India) ABSTRACT
TECHNICAL BULLETIN hydrocarbons
TECHNICAL BULLETIN hydrocarbons SUMMARY Introduction: Hydrocarbons 4 I. Properties 4 II. Lubricants 9 III. System Design 10 IV. Safety Aspects 14 V. Retrofitting 17 VI. FAQs (Frequently Asked Questions)
R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP
R-32 The next generation refrigerant for air conditioners and heat pumps Superior energy efficiency and low GWP HFC phase-down and the introduction of R32 The European phase-down of HFCs, which will see
EU f-gas regulation EN 517/2014.
F-gas regulation EU f-gas regulation EN 517/2014. Helping you meet your environmental obligations. 02 EU f-gas regulation EU f-gas regulation. Reducing your environmental impact. The updated f-gas regulation
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture
Revision Date: 05/19/2015 Date of issue: 05/19/2015 Version: 1.0 SECTION 1: IDENTIFICATION 1.1. Product Identifier Product Form: Mixture Product Name: 10X Spheroid Formation ECM Product Code: 3500-096-01
AIR CONDITIONING COMPRESSOR OIL
AIR CONDITIONING COMPRESSOR OIL PAG, PAO and POE oils AIR CONDITIONING COMPRESSOR OIL THERE ARE LOTS OF OILS AVAILABLE, WHICH ONE IS RECOMMENDED? Oil plays an important role in the air conditioning system:
MATERIAL SAFETY DATA SHEET Product Code: 10033
MATERIAL SAFETY DATA SHEET Product Code: 10033 Product Description: Signal Horn & Refilling Canister in Blister Pack 1. IDENTIFICATION OF THE PRODUCT AND OF THE COMPANY: Product Name: Signal Horn & Refilling
Centrifugal Water Chillers. Scott Meyerkord
Centrifugal Water Chillers Scott Meyerkord Trane Account Manager Chilled Water System absorption centrifugal helical-rotary Centrifugal Water Chillers Centrifugal Water Chillers Components components of
KEEPING COOL: AIR CONDITIONING
TECH NOTE KEEPING COOL: AIR CONDITIONING Words: Dougie Photos: Steve McCann As the weather gets warmer, we take an in-depth look at all the gas and gubbins that keeps you feeling cool when you re out cruising
Maintenance for Energy Efficiency
Maintenance for Energy Efficiency Institute of Hospital Engineering, Australia (IHEA) Seminar Asset Management & Energy Efficiency Exclusive Trane distributor Australia/New Zealand. The TRANE trade mark
2010 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC)
2010 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC) 2010 Assessment Montreal Protocol on Substances that Deplete the Ozone Layer Celebrating 25 years of
Information on New Refrigerant (R-1234yf) for A/C Service
Information on New Refrigerant (R-1234yf) for A/C Service 2013 Cadillac ATS, XTS This bulletin is being revised to include procurement and labeling information for recovery cylinders to be used with GE-50957-Contaminated
Fujitsu General New Zealand Ltd
Fujitsu General New Zealand Ltd Ozone layer protection Global warming prevention HCFC (R22) Ozone depletion potential : 0.055 Global warming potential : 1,810 1987 Montreal Protocol adoption Complete abolishment
(Adopted July 7, 1989)(Amended December 7, 1990) (Amended May 13, 1994) FUGITIVE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS
(Adopted July 7, 1989)(Amended December 7, 1990) (Amended May 13, 1994) RULE 1173. FUGITIVE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS (a) (b) Purpose This rule is intended to control volatile organic compounds
Safety data sheet. May cause slight irritation to the skin and eyes.
Safety data sheet Revision: 16-04-2015 Replaces: 09-05-2014 Version: 03.00/GBR SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Trade name: LFFM
Certification Training Manual
Keep this book! You may need it for your retest. Revised 01/2015 Certification Training Manual Approved by the U.S. EPA for technician training requirements under Section 609 of the Clean Air Act. Including:
: DuPont ISCEON MO79 refrigerant
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
Analysis of Alternative Refrigerants to HCFC-22
2014 3rd International Conference on Informatics, Environment, Energy and Applications IPCBEE vol.66 (2014) (2014) IACSIT Press, Singapore DOI: 10.7763/IPCBEE. 2014. V66. 34 Analysis of Alternative Refrigerants
Engineering Recommendation on: Accumulators Revised 6-17-99 Issued January 10, 1979 Page 1 of 7
Issued January 10, 1979 Page 1 of 7 Accumulators have long been recognized by the industry as an effective means of maintaining good system balance by storing excess refrigerant as the condenser or evaporator
: DuPont SUVA 134aUV Leakdetect
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS
www.arpapress.com/volumes/vol9issue3/ijrras_9_3_02.pdf THE POSSIBILITY OF USING LIQUIFIED PETROLEUM GAS IN DOMESTIC REFRIGERATION SYSTEMS Zainal Zakaria 1 & Zulaikha Shahrum 2 Department of Gas Engineering,
: MR MUSCLE Window & Glass Cleaner
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING Product information Product identifier : Relevant identified uses of the substance or mixture and uses advised against : Hard Surface
WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D
1. PRODUCT AND COMPANY IDENTIFICATION Product information Product name : WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA- D Recommended use : Hard Surface Cleaner Manufacturer, importer, supplier : S.C. Johnson
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Guidance for Stationary Refrigeration & Air-Conditioning
Information Sheet RAC 3 Key Obligations Guidance for Stationary Refrigeration & Air-Conditioning This Information Sheet provides a description of the key obligations under the EC F gas and Ozone Regulations
MATERIAL SAFETY DATA SHEET
DOT ID No: UN 2187 MATERIAL SAFETY DATA SHEET DOT Hazard Class: 2.2 Emergency No.: +971-6-5336481 Page No. : 1/5 DOT Shipping Label : Non Flammable Gas Date last updated: 22/09/2009 Revision no: 00 1.
DuPont ISCEON MO89 refrigerant
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
Environmental Guideline for Ozone Depleting Substances (ODS s) and Halocarbon Alternatives
Environmental Guideline for Ozone Depleting Substances (ODS s) and Halocarbon Alternatives 1 Introduction 1.1 Background 1.2 Guideline Purpose 1.3 Definitions 2 Roles and Responsibilities 2.1 Department
Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system
AURETU004 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system 2. Diagnose air conditioning and
1. IDENTIFICATION: PRODUCT IDENTIFIER AND CHEMICAL IDENTITY
1. IDENTIFICATION: PRODUCT IDENTIFIER AND CHEMICAL IDENTITY Product Name Proper Shipping Name Other Names Recommended Use Supplier Name Address Telephone No. Australian Emergency Contact No. 2. HAZARDS
: Sharpie King Size Permanent Markers. 3500 Lacey Road, 10th Floor Downers Grove, IL 60515 USA 800-323-0749 or 630-829-2500
PRODUCT DATA SHEET Section 1. Identification Product name : Sharpie King Size Permanent Markers Material uses : Writing instruments Manufacturer : Newell Brands 3500 Lacey Road, 10th Floor Downers Grove,
OFF! DEEP WOODS SPORTSMEN INSECT REPELLENT I (PUMP SPRAY)
1. PRODUCT AND COMPANY IDENTIFICATION Product information Trade name : OFF! DEEP WOODS SPORTSMEN INSECT REPELLENT I (PUMP Use of the : Insect Repellent Substance/Preparation Company : S.C. Johnson and
Quebec Quebec Tel : 418-834-7447 Fax : 418-834-3774 MSDS: P10 (10% Methane in Argon) PRODUCT INFORMATION
Tel: 514-956-7503 Fax: 514-956-7504 Internet: www.megs.ca Email : [email protected] Montreal Ottawa St-Laurent Nepean Tel : 514-956-7503 Tel : 613-226-4228 Fax : 514-956-7504 Fax : 613-226-4229 Quebec Quebec
SAFETY DATA SHEET. Section 1: Identification of the substance/mixture and of the company/undertaking. KaVo Everest ZS-Blanks und Ronden
SAFETY DATA SHEET Section 1: Identification of the substance/mixture and of the company/undertaking Product identifier Trade name or designation of the mixture REACH Registration Number KaVo Everest ZSBlanks
SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.
SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING Effective From :- UNDER DEVELOPMENT Prepared by: Curriculum development cell Institute of Research Development
ThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2