DYNACIAT LG. Water-cooled chillers
|
|
- Allan Ramsey
- 7 years ago
- Views:
Transcription
1 High power efficiency Compact and quiet Scroll compressors Brazed plate heat exchangers Electronic control system Cooling or heating ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity : 35 to 350 kw Heating capacity : 40 to 415 kw USE The water-cooled packaged LG DYNACIAT series of chillersheaters are especially designed to supply chilled or hot water with a middle capacity for air conditioning application systems encountered in collective and commercial buildings, as well as industrial premises and processes.these packaged units are designed to be implanted as standard indoors in a technical plant, sheltered against adverse weather and frost. To operate in COOLING mode, these units must be cooled by a water circulation coming from an external source, such as underground water or city water if using a water flow control valve, or connected to an external water drycooler or a cooling tower. RANGE - LGP series Water-cooled chillers or heat pump models DYNACIAT ILG series Water to Water reversible heat pumps models On a water supply, the LGP series can be used as a heat pump during winter time. Connected to a heating or cooling floor, fan coil units or an air handling unit, a LGP series heat pump allows the heating and the air conditioning of buildings thanks to a set of valves located on the water circuit (not supplied). Each unit is assembled, internally wired (logic and starting box), charged with refrigerant, and is subject to a operation test in the factory. The installation work is simple, and the only operations required on site are electrical wiring and water piping connections. N series Chiller models without condenser (for split system) SPECIFICATIONS series units are supplied as standard with the following components: - water cooled condenser, - chiller evaporator, - capacity control system on outlet chilled or hot water, - logic, control and starting electric box :. Power supply : 3~50Hz 400V (+6%/-10%) + earth. Logic circuit : 1~50Hz 230V (+6%/-10%) (transformers are mounted on the unit as standard feature), - cabinet for indoor installation. Conformity with the EC European directives - "LOW VOLTAGE" directive (LVD), - Machines 98 / 37 CEE - Electromagnetic EMC 89 / 336 CEE - Pressure vessels DESP 97 / 23 CEE category 2 (LG-LGP-ILG) DESP is not applicable (LGN) unit not complete Conforms to standards - EN and EN
2 TECHNICAL AND ELECTRICAL CHARACTERISTICS DynaCiat LG - LGP 120V 150V 200V 240V 300V 350V 400V 500V 540V 600V 753Z 900Z 1000Z 1100Z 1200Z Cooling capacity ➀ kw Power input ➀ kw Efficiency EER Heating capacity ➁ kw Power input ➁ kw , COP Sound power level db(a) Compressor Starting mode Hermetic SCROLL 2900 rpm Direct in line in series Quantity Oil quality POE 3MAF (32 cst). POE ISO32-160SZ Oil volume l (cir1) l (cir2) Refrig. circuit no. 1 2 Refrigerant type R410A R407C Refrigerant weight kg (cir1) kg (cir2) Electric supply ph/hz/v 3~50Hz 400V (+6%/-10%) + Earth Maxi rated current A Starting current A Starting current Soft Start option A Breaking capacity ka Electric box protection IP22 Maxi wires section mm Control voltage ph/hz/v 1~50Hz 230V (+6%/-10%) transformer mounted Capacity control % Evaporator Brazed plate heat exchanger type Water content l Outlet water mini Maxi C -10 C / +18 C -8 C / +12 C Minimum water flow m 3 /h Maximum water flow m 3 /h Water connections G 1"1/4 G 1"1/2 G 2" G 2"1/2 DN80 PN16 DN100 PN16 DN125 PN16 Design pressure bar 10 bars WATER side Condenser Brazed plate heat exchanger type Water content l Outlet water mini Maxi C +30 C / +55 C +30 C / +50 C Minimum water flow m 3 /h Maximum water flow m 3 /h Water connections G 1"1/2 G 2" G 2"1/2 DN80 PN16 DN100 PN16 DN125 PN16 Design pressure bar 10 bars WATER side Storage mini Maxi C -20 C / +50 C Mini water pipe content l Operating height 4 mm Length mm Width mm Weight empty kg Weight in operation kg Capacities based on: ➀ / COOLING mode : +12 C/+7 C and +30 C/+35 C ➁ / HEATING mode : +40 C/+45 C and +12 C/+7 C 3 EER and COP are gross values 4 Height without lifting accessories 2 2
3 TECHNICAL AND ELECTRICAL CHARACTERISTICS DynaCiat ILG 120V 150V 200V 240V 300V Cooling capacity ➀ kw 29,2 38,0 50,8 59,1 77,0 Power input ➀ kw 8,0 10,2 13,9 15,8 20,2 Efficiency EER 3 3,65 3,72 3,65 3,74 3,81 Heating capacity ➁ kw 38,9 50,8 67,9 78,6 101,5 Power input ➁ kw 9,1 11,7 16,1 18,1 23,3 COP 3 4,27 4,34 4,22 4,34 4,35 Sound power level db(a) Compressor Hermetic SCROLL 2900 rpm Starting mode Direct in line in series Quantity 1 2 Oil quality POE 3MAF (32 cst). Oil volume l (cir1) Refrig. circuit no. 1 Refrigerant type Refrigerant weight kg (cir1) Electric supply ph/hz/v 3~50Hz 400V (+6%/-10%) + Earth Maxi rated current A Starting current A Starting current Soft Start option A Breaking capacity ka 50 Electric box protection Maxi wires section mm Control voltage ph/hz/v 1~50Hz 230V (+6%/-10%) transformer mounted Capacity control % Internal circuit R410A IP22 Brazed plate heat exchanger type Water content l Minimum water flow m 3 /h 5 6, ,5 Maximum water flow m 3 /h Water connections G 1"1/2 G 2" Design pressure bar 10 bars WATER side External circuit Brazed plate heat exchanger type Water content l Minimum water flow m 3 /h 5 6, ,5 Maximum water flow m 3 /h Water connections G 1"1/2 G 2" Design pressure bar 10 bars WATER side Storage mini Maxi C -20 C / +50 C Mini water pipe content l Operating height 4 mm Length mm Width mm Weight empty kg Weight in operation kg Capacities based on: ➀ / COOLING mode : +12 C/+7 C and +30 C/+35 C ➁ / HEATING mode : +40 C/+45 C and +12 C/+7 C 3 EER and COP are gross values 4 Height without lifting accessories 3
4 TECHNICAL AND ELECTRICAL CHARACTERISTICS DynaCiat LGN 120Z 150Z 200Z 240Z 300Z 350Z 400Z 500Z 540Z 600Z 753Z 900Z 1000Z 1100Z 1200Z Cooling capacity ➀ kw Power input kw Discharge capacity ➀ kw Efficiency EER ➁ Sound power level db(a) Compressor Starting mode Hermetic SCROLL 2900 rpm Direct in line in series Quantity Oil quality POE ISO32-160SZ POE ISO32-160SZ Oil volume l (cir1) l (cir2) Refrig. circuit no. 1 2 Refrigerant type Refrigerant weight R407C Refrigerant not supplied (nitrogen charge) Electric supply ph/hz/v 3~50Hz 400V (+6%/-10%) + Earth Maxi rated current A Starting current A Starting current Soft Start option A Breaking capacity ka Maxi wires section mm Electric box protection IP22 Control voltage ph/hz/v 1~50Hz 230V (+6%/-10%) - transformer mounted Capacity control % Evaporator Brazed plate heat exchanger type Water content l Outlet water mini Maxi C -10 C / +12 C -8 C / +12 C Minimum water flow m 3 /h Maximum water flow m 3 /h Water connections G 1"1/4 G 1"1/2 G 2" G 2"1/2 DN80 PN16 DN100 PN16 DN125 PN16 Design pressure bar 10 bars WATER side Discharge circuit Without condenser Balance circuit 1 / circuit 2 % /46 50/50 67/33 56/44 50/50 50/50 50/50 Evaporator (cir1) 1"1/8 1"1/8 1"3/8 1"3/8 1"5/8 1"5/8 2"1/8 2"1/8 1"3/8 1"5/8 2"1/8 2"1/8 2"1/8 2"1/8 2"1/8 Water content (cir2) "5/8 1"5/8 1"3/8 2"1/8 2"1/8 2"1/8 2"1/8 Outlet water mini Maxi (cir1) 7/8 7/8 7/8 1"1/8 1"1/8 1"1/8 1"3/8 1"3/8 1"1/8 1"1/8 1"3/8 1"1/8 1"1/8 1"5/8 1"5/8 Minimum water flow (cir2) "1/8 1"1/8 1"1/8 1"3/8 1"3/8 1"5/8 1"5/8 Maximum water flow bar 29.5 bar HP Water connections C -20 C / +50 C Design pressure l Operating height 3 mm Length mm Width mm Weight empty kg Weight in operation kg ➀ Capacities based on : COOLING mode: +12 C/+7 C and condensing +45 C ➁ EER is gross value 3 Height without lifting accessories 4
5 MAIN COMPONENTS Framework - casing with removable sheets in galvanized steel, - enamelled paint colors RAL 7024 and RAL 7035 Hermetic SCROLL compressors - Integral motor cooled by suction gas - Motor protection by a winding internal thermostat - Mounting on antivibration mounts Evaporator - Brazed plate heat exchanger(s) type - End plates and internal plates in AISI 316 stainless steel - High performance optimized plates profile - Thermal insulation Condenser LG - LGP - ILG Series - Brazed plate heat exchanger(s) type - End plates and internal plates in AISI 316 stainless steel - High performance optimized plates profile - Thermal insulation LGN Series - Chiller without condenser - Possibility of connection on a removed air cooled condenser EUROPA 2C or AIRIAL series - Refrigeration sleeves for LGN (without condenser). Control and safety devices - Thermostatic expansion valve - High and low refrigerant pressure switch - Safety relief valves on refrigerant circuit - Temperature sensors and pressure transducers - Chilled water flow switch - Unit starting sequence Connect electronic control system A CIAT microprocessor electronic control system, with CPU, with centralization of controls and monitoring of internal operating. Including: - Selector for Run, Stop, Reset or Remote, - Running mode selector, COOLING or HEATING, - Output. RS485 output for BMS control (ModBus-JBus),. Output adapter for additional potential-free contact board,. Output adapter for remote control (optional). - LCD screen for output or internal operation and LED sight glasses Functions: - Monitoring of operating information by :. direct display of clear text messages in different languages. direct display of temperatures and pressures - Global compressors control with starting sequence, counting and equalization of compressors running times - Anti-short cycle protection - Auto-adaptative functions with adjustment of the control system on the running parameters deviation - Capacity stage control system on each compressor (multi compressors) in accordance with the cooling or heating requirements controlled by the water temperatures - Control of the internal operating parameters - Second setting point control - Direct display of water temperatures - Diagnosis of operating status and faults : HP/LP, water flow, compressor(s) motor(s), anti-frost - Remote management and remote control OPTIONAL EQUIPMENT (KITTO BE MOUNTED ON-SITE) Electrical box The entire assembly electric box, containing all the electric components and control process unit (CPU), allows complete control of the functions of the machine, operation monitoring, adjustment of the water temperature settings, or interface with an external managing system. The electric box includes: - Power circuit and remote control circuit - Wiring numbering - Main safety switch breaker on front panel with handle - Control circuit transformer - Circuit breaker protections on power and control circuits - Compressor(s) motor(s) contactor(s) - General earth connection - Microprocessor electronic system Micro Connect ILG Connect for LG - LGP - LGN - Free contacts for field wiring signals report. Optional equipment (delivered separately) - Remote control box, (Except ILG) - Additional potential-free contact board, (Except ILG) - Evaporator and condenser flexible connectors, microns water filter, evaporator and condenser, - For city water use (LG ), condenser 2-way control valve, - For starting with low water temperature (LG ) condenser 3-way control valve, - Phase rotation detecter (rotation, phase failure, over voltage, under voltage), - Soft starter, 5
6 OPERATING RANGE Water-cooled chillers LG-LGP 120V - 600V LG-LGP LGN 120Z Z Condenser water outlet C EVAPORATOR LIMITS Condenser water outlet C Necessary Glycol Necessary Glycol Necessary Glycol Chilled water outlet C Chilled water outlet C Chilled water outlet C Condensation temperature C The curves represent the minimum and maximun allowable temperature difference of chilled water (or glycol) in accordance with the outlet temperature. Water glycol Example: For a water outlet: + 5 C mini difference: 2,6 C Water temp.: 7,6 / 5 C Max. difference: 6 C Water temp.: 11 / 5 C For temperature differences not included between the 2 curves, consult us. Admissible water inlet/outlet difference C Brazed plate evaporator Water outlet temperature ( C) WATER GLYCOL COEFFICIENTS 30 % concentration of glycol weight Freezing point of the solution: -17,5 C. K: Correction cœfficients Reading valves in the brochure Pf: Refrigeration power according to selection tables Pa: Compressor absorbed power according to selection tables DP: Water pressure drop according to curves for the corresponding corrected flow rate value (Qc). Corrected values according to calculations above: Pfc: Corrected cooling capacity Qc: Corrected chilled or hot water flow rate DPc: Corrected water pressure drop, evaporator or condenser. Evaporator Condenser Evaporator + condenser CORRECTION Difference of temperature for performances calculation tables POSITIVE TEMPERATURE NEGATIVE TEMPERATURE K Calculation K Calculation Cooling capacity 0,98 Pfc = Pf x 0,98 1,00 see selection table Chilled water Pcf x 0.86 Pcf x ,05 Qc = x 1,05 1,10 Qc = x 1,10 flow ΔT ΔT Pressure drop 1,15 ΔPc = ΔP x 1,15 1,30 ΔPc = ΔP x 1,30 Average temp. 12 / 7 C see operating limits Cooling capacity 0,97 Pfc = Pf x 0,97 Chilled water flow 1,05 (Pcf+Pa) x 0.86 Qc = x 1,05 ΔT Pressure drop 1,10 ΔPc = ΔP x 1,10 Average temp. 35 / 40 C Cooling capacity 0,95 Pfc = Pf x 0,95 0,97 Pfc = Pf x 0,97 Chilled water flow 1,05 Pcf x 0.86 Qc = x 1,05 ΔT 1,10 Pcf x 0.86 Qc = x 1,10 ΔT Pressure drop 1,15 ΔPc = ΔP x 1,15 1,30 ΔPc = ΔP x 1,30 Hot water flow 1,05 Condenser pressure drop (Pcf+Pa) x 0.86 Qc = x 1,05 ΔT 1,05 (Pcf+Pa) x 0.86 Qc = x 1,05 ΔT 1,10 ΔPc = ΔP x 1,10 1,10 ΔPc = ΔP x 1,10 6
7 MINIMUM WATER PIPES VOLUME The Connect controller is equipped with an anticipation logic allowing high flexibility in adjusting the set points according to the parameters drifting, in particular for low water volume hydraulic installations. An adapted management of the compressors operating periods avoids therefore the start of anti-short cycle functions, and in most cases, the requirement of a buffer tank. Models LG - LGP - ILG 120V 150V 200V 240V 300V 350V 400V 500V 540V 600V 753Z 900Z 1000Z 1100Z 1200Z Minimum installation volume (liters) NOTES: Industrial processes which require a high stability of water temperatures or installations with high thermal load variation can privilege the installation of a water buffer tank. NOISE LEVELS The - LGP - LGN - ILG range is a must by its design integrating the "noiseless" assembly process for attenuation of vibrations and sound power sources : Scroll compressor(s) mounted on antivibration mounts Anti-vibratil assembly of several compressors on structure isolated from the frame (120 to 600) Piping dissociated from the unit structure Double skin paneling with mineral wool insulation 25 mm (753 to 1200) Antivibration mounts to be positioned between the ground and the unit as standard (753 to 1200) Sound power levels ref 2x10-12 Pa ±3 db Sizes POWER LEVEL SPECTRUM (db) Global level Lw 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz db(a) Sound pressure levels ref 2x10-5 Pa ±3 db Measuring point: in free field 10 meters from the unit, 1.50 meters from the ground directivity 2 Sizes PRESSURE LEVEL SPECTRUM (db) Global level Lp 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz db(a)) NOTES: Acoustic pressure levels depend on installation conditions, and consequently are only indicative. Reminder: only the sound power levels are comparable and certified. Compliance with ISO 3744 standard Lp = Lw - 10 log S 7
8 COOLING AND HEATING CAPACITIES - LGP Water-cooled chillers ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION DE L'ENVIRONNEMENT R410A LG LGP 120V 150V 200V 240V 300V 350V 400V Evaporator water outlet temperature C CONDENSER WATER OUTLET TEMPERATURE C Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw ,1 6,9 52,8 44,3 7,6 51,7 42,3 8,3 50,4 40,0 9,2 49,0 37,4 10,2 47,3 34,6 11,5 45, ,2 7,0 57,1 48,2 7,7 55,7 46,0 8,4 54,2 43,7 9,2 52,6 40,9 10,3 50,9 37,9 11,4 48, , ,5 9,0 69,3 58,3 9,8 67,8 55,8 10,7 66,2 52,9 11,8 64,4 49,6 13,2 62,4 46,3 14,7 60, ,9 9,3 75,0 63,6 10,0 73,4 60,6 10,8 71,2 57,8 11,9 69,4 54,4 13,2 67,2 50,9 14,6 65, ,8 11,9 93,4 78,5 13,1 91,3 75,0 14,5 89,2 70,8 16,1 86,4 66,4 18,0 83,7 60,9 20,4 80, ,0 12,1 100,9 85,5 13,3 98,6 81,6 14,7 96,0 77,8 16,2 93,5 72,5 18,2 90,1 67,0 20,3 86, ,9 14,0 105,5 87,7 15,2 102,5 84,3 16,7 100,6 79,5 18,5 97,5 74,4 20,5 94,2 68,3 23,0 90, ,7 14,2 113,6 96,0 15,5 111,1 91,8 16,9 108,2 86,7 18,7 104,8 81,3 20,6 101,3 75,3 23,0 97, ,5 18,1 139,2 116,9 19,5 136,0 111,9 21,4 132,7 106,6 23,6 129,5 100,4 26,2 125,7 92,6 29,5 121, ,3 18,6 150,5 127,6 20,0 147,2 122,2 21,7 143,3 116,4 23,8 139,5 109,1 26,4 134,7 102,5 29,3 130, ,5 21,0 163,1 135,9 22,8 158,2 129,9 24,9 154,2 122,7 27,4 149,4 115,4 30,4 144,8 107,2 34,2 140, ,1 21,6 177,2 149,0 23,3 171,7 141,8 25,3 166,5 134,7 27,8 161,8 126,3 30,8 156,1 116,8 34,3 150, ,9 23,6 186,0 156,1 25,7 181,2 150,2 28,1 177,6 141,5 30,8 171,5 132,4 34,2 165,5 122,2 38,3 159, ,7 24,1 201,4 171,1 26,1 196,7 162,0 28,6 189,9 154,8 31,2 185,1 145,5 34,4 178,9 134,2 38,3 171,2 Pf: Cooling output Pa: Compressor power input Pc: Heating capacity Zone where use of water / glycol is compulsory Calculation fouling m 2 C/W Eurovent conditions 8
9 COOLING AND HEATING CAPACITIES - LGP R410A R407C LG LGP 500V 540V 600V 753Z 900Z 1000Z 1100Z 1200Z Evaporator water outlet temperature C ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION DE L'ENVIRONNEMENT ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT CONDENSER WATER OUTLET TEMPERATURE C Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw ,3 29,2 231,9 195,2 31,9 226,3 186,8 35,0 220,9 175,5 38,3 212,7 164,1 42,3 205,0 150,2 47,5 195, ,8 29,7 252,0 212,7 32,3 244,4 203,4 35,3 237,9 192,2 38,7 229,9 179,9 42,7 221,4 166,1 47,7 212, ,4 32,1 243,8 203,5 34,8 237,5 194,9 38,2 232,0 184,2 42,2 225,1 173,5 46,8 218,7 160,1 52,2 210, ,5 32,9 262,7 223,4 35,6 258,2 212,6 38,7 249,9 201,6 42,5 242,9 189,5 47,2 235,2 174,4 52,8 225, ,8 36,3 278,4 234,0 39,2 272,3 223,9 42,9 265,8 212,6 47,2 258,4 199,5 52,7 250,5 184,7 59,2 241, ,6 37,2 301,1 254,0 40,1 293,2 244,0 43,4 286,3 231,4 47,9 277,9 218,6 53,0 270,0 203,7 59,3 261, Pf: Cooling output Pa: Compressor power input Pc: Heating capacity Zone where use of water / glycol is compulsory Calculation fouling m 2 C/W Eurovent conditions 9
10 COOLING CAPACITIES - COOLING MODE DYNACIAT ILG ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION DE L'ENVIRONNEMENT CONDENSER WATER OUTLET TEMPERATURE C ILG Evaporator water outlet temperature C Pf Pa Pf Pa Pf Pa Pf Pa Pf Pa Pf Pa kw kw kw kw kw kw kw kw kw kw kw kw 5 28,9 7,1 27,3 7,9 25,6 8,8 23,8 9,9 21,8 11,1 19,8 12,3 7 31,0 7,1 29,2 8,0 27,4 8,9 25,5 9,9 23,4 11,1 21,4 12,3 120V 12 36,5 7,2 34,5 8,0 32,5 8,9 30,5 9,9 28,2 11,1 25,9 12, ,0 7,3 38,0 8,0 36,0 8,9 33,5 9,9 31,0 11,1 28,7 12, ,5 7,3 41,5 8,1 39,5 8,9 37,0 9,9 34,5 11,1 32,0 12,3 150V 5 37,0 9,2 35,5 10,1 33,5 11,3 31,5 12,6 29,3 14,0 27,0 15,4 7 40,0 9,2 38,0 10,2 35,9 11,4 33,8 12,7 31,5 14,1 29,0 15, ,0 9,3 45,0 10,3 42,6 11,4 40,0 12,8 37,5 14,3 34,8 15, ,5 9,4 49,0 10,3 46,5 11,5 44,0 12,8 41,0 14,3 38,5 15,8 R410A 18 56,5 9,5 54,0 10,4 51,0 11,5 48,3 12,8 45,0 14,3 42,0 15,8 5 50,2 12,3 47,4 13,8 44,2 15,6 41,0 17,6 37,4 19,9 33,8 22,2 7 53,6 12,4 50,8 13,9 47,4 15,6 44,0 17,6 40,4 19,9 36,8 22,2 200V 12 63,7 12,5 60,2 13,9 56,8 15,6 52,8 17,6 48,6 19,9 44,6 22, ,0 12,5 66,0 14,0 62,5 15,6 58,4 17,6 54,0 19,9 49,6 22, ,0 12,6 72,0 14,0 68,0 15,7 64,0 17,7 59,6 19,9 55,0 22,2 240V 5 58,6 14,2 55,4 15,8 51,9 17,6 48,2 19,8 44,2 22,2 40,4 24,6 7 62,0 14,2 59,1 15,8 55,6 17,6 51,8 19,8 47,6 22,2 43,4 24, ,6 14,4 70,0 16,0 66,0 17,8 62,0 19,8 57,2 22,2 52,4 24, ,0 14,4 77,0 16,0 73,0 17,8 68,3 19,8 63,0 22,2 58,2 24, ,0 14,6 84,0 16,0 80,0 17,8 75,2 19,8 69,6 22,2 64,0 24,4 300V 5 76,0 18,2 72,0 20,2 68,0 22,4 64,0 25,0 59,4 28,0 55,0 30,6 7 80,7 18,2 77,0 20,2 73,0 22,6 68,7 25,2 64,0 28,0 59,0 30, ,0 18,6 91,0 20,4 86,0 22,8 81,0 25,4 75,6 28,4 70,7 31, ,0 18,8 100,0 20,6 95,0 22,8 89,2 25,4 83,7 28,4 78,0 31, ,5 19,0 109,0 20,8 104,0 23,0 98,0 25,6 92,0 28,6 86,0 31,4 Pf : Cooling output Pa : Compressor power input Zone where use of chilled water is compulsory. Calculation fouling 0,00005 m 2 C/W Eurovent conditions 10
11 HEATING CAPACITIES - HEATING MODE DYNACIAT ILG R410A ILG 120V 150V 200V Evaporator water outlet temperature C CONDENSER WATER OUTLET TEMPERATURE C ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION DE L'ENVIRONNEMENT Pc Pa Pc Pa Pc Pa Pc Pa Pc Pa Pc Pa kw kw kw kw kw kw kw kw kw kw kw kw -8 26,9 6,5 26,4 7,3 25,7 8,3 24,8 9,1-4 30,2 6,5 29,5 7,2 28,8 8,2 28,0 9,1 27,1 10,3 2 35,9 6,6 35,2 7,3 34,3 8,1 33,4 9,2 32,6 10,3 31,2 11,9 5 39,9 6,6 38,9 7,3 38,0 8,1 36,9 9,1 35,9 10,2 34,8 11,4 7 42,2 6,6 41,1 7,3 40,1 8,2 38,9 9,1 37,6 10,2 36,5 11, ,6 6,7 44,5 7,4 43,4 8,2 42,1 9,1 40,8 10,1 39,3 11, ,5 6,8 47,3 7,5 46,0 8,2 44,6 9,1 43,1 10,1 41,7 11,4-8 34,6 8,2 34,0 9,2 33,5 10,3 32,7 11,4-4 38,7 8,3 38,0 9,2 37,4 10,4 36,6 11,5 35,9 12,9 2 46,3 8,4 45,3 9,3 44,5 10,5 43,8 11,7 42,8 13,0 41,5 14,5 5 51,4 8,5 50,4 9,4 49,4 10,5 48,4 11,7 47,0 13,1 45,9 14,8 7 54,2 8,6 53,2 9,5 52,2 10,5 50,8 11,7 49,5 13,1 48,5 14, ,8 8,7 57,6 9,6 56,3 10,6 54,8 11,8 53,3 13,2 51,7 14, ,4 8,9 61,2 9,7 59,7 10,6 58,1 11,8 56,6 13,1 54,8 14,8-8 46,4 11,1 45,0 12,7 44,1 14,4 43,3 16,3-4 52,3 11,1 50,9 12,6 50,2 14,3 49,1 16,2 47,7 18,2 2 62,3 11,3 60,9 12,7 59,6 14,3 58,0 16,1 56,1 18,0 54,7 20,6 5 69,6 11,4 67,9 12,8 66,2 14,3 64,5 16,0 62,8 18,2 61,1 20,2 7 73,1 11,5 71,3 12,8 69,6 14,3 67,9 16,1 66,0 18,2 64,1 20, ,5 11,6 77,8 12,9 75,4 14,4 73,5 16,2 71,0 18,2 68,7 20, ,7 11,7 82,2 13,0 80,2 14,4 78,0 16,1 75,4 18,1 73,0 19,9 240V 300V -8 53,1 13,1 52,3 14,6 51,7 16,6 50,5 18,6-4 59,8 13,0 58,6 14,6 57,8 16,5 56,5 18,6 55,4 20,9 2 71,3 13,2 69,9 14,7 68,4 16,5 66,8 18,5 65,6 20,8 63,8 23,3 5 80,8 13,2 78,8 14,6 76,8 16,3 74,3 18,2 72,1 20,4 69,9 22,9 7 85,0 13,3 83,2 14,7 81,1 16,3 78,6 18,1 76,1 20,4 73,6 22, ,4 13,5 89,6 14,9 87,7 16,4 85,5 18,2 82,7 20,3 79,6 22, ,2 13,7 96,1 15,0 93,5 16,5 90,9 18,2 87,3 20,3 84,2 22,8-8 69,1 16,5 67,7 18,3 66,4 20,6 65,1 23,0-4 77,7 16,7 76,6 18,4 75,0 20,7 73,7 23,2 72,2 25,7 2 92,6 16,9 91,1 18,6 89,5 20,8 87,8 23,4 85,5 26,0 83,1 28, ,3 17,0 101,4 18,8 99,4 20,9 97,2 23,3 94,5 26,0 91,5 29, ,9 17,1 106,3 18,8 104,1 20,9 101,5 23,3 98,9 26,1 95,1 29, ,2 17,4 114,6 19,1 112,1 21,1 109,1 23,4 106,2 26,2 101,6 29, ,1 17,5 121,3 19,3 118,6 21,3 115,7 23,4 112,5 26,3 107,7 29,9 Pf : Cooling output Pa : Compressor power input Zone where use of chilled water is compulsory. Calculation fouling 0,00005 m 2 C/W Eurovent conditions 11
12 COOLING AND HEATING CAPACITIES REJECTED ON REMOTE CONDENSER N Water-cooled chillers ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT R407C LGN 120Z 150Z 200Z 240Z 300Z 350Z 400Z Evaporator water outlet temperature C CONDENSING TEMPERATURE C Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw Pf: Cooling output Pa: Compressor power input Pc: Heating capacity to evacuate Zone where use of water / glycol is compulsory Calculation fouling m 2 C/W Standard conditions 12
13 COOLING AND HEATING CAPACITIES REJECTED ON REMOTE CONDENSER N R407C LGN 500Z 540Z 600Z 753Z 900Z 1000Z 1100Z 1200Z ENVIRONMENTALLY HFC R407C PROTECTION DE CONDENSING TEMPERATURE C Evaporator water outlet temperature Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc Pf Pa Pc C kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw FRIENDLY L'ENVIRONNEMENT Pf: Cooling output Pa: Compressor power input Pc: Heating capacity to evacuate Zone where use of water / glycol is compulsory Calculation fouling m 2 C/W Standard conditions 13
14 WATER PRESSURE DROP LG - LGP Condenser and evaporator Water-cooled chillers (prohibited use outside limit applications) EVAPORATOR 160 Water pressure drop in kpa Water flow m 3 /h CONDENSER 160 Water pressure drop in kpa Water flow m 3 /h Units conversion formulae kpa = bar x 100 bar = mh2o x kg/cm2 = bar x Pi (lbf/in2) = bar x Inches (in) = mm x Foot (ft) = mm x Pounds (lb) = kg x Cubic foot mn (cfm) = m3/h x US Gallons = m3 x UK Gallons = m3 x
15 WATER PRESSURE DROP LGN Condenser and evaporator (prohibited use outside limit applications) EVAPORATOR Water pressure drop in kpa Water flow m 3 /h Filter - LG - LGP - LGN (compulsory) Water pressure drop in mce EVAP EVAP COND EVAP COND EVAP COND EVAP - COND EVAP - COND EVAP - COND Water flow m 3 /h 15
16 WATER PRESSURE DROP ILG Water-cooled chillers Evaporator (prohibited use outside limit applications) INTERNAL CIRCUIT AND EXTERNAL CIRCUIT Water pressure drop in kpa Filter - ILG (compulsory) 8 6 Water flow m 3 /h Water pressure drop in mce ILG ILG Water flow m 3 /h Units conversion formulae kpa = bar x 100 bar = mh2o x kg/cm2 = bar x Pi (lbf/in2) = bar x Inches (in) = mm x Foot (ft) = mm x Pounds (lb) = kg x Cubic foot mn (cfm) = m3/h x US Gallons = m3 x UK Gallons = m3 x
17 DIMENSIONS - LGP F 3 x D E 90 A a : Condenser cooling water outlet (LG) Condenser hot water outlet (LGP) b : Condenser cooling water inlet (LG) Condenser hot water inlet (LGP) 1591 c : Evaporator chilled water outlet d : Evaporator chilled water inlet e : Electrical supply Anti-vibration mounts LG-LGP Figure Mass Kg a - b G 1 1/2 c - d G 1 1/4 Male connectors Flange PN16 G 1 1/2 G 2 G 2 1/2 DN 80 DN 100 DN 125 A B C D E F Empty In operation
18 DIMENSIONS Water-cooled chillers N F 3 x G D E A 90 a : Discharge pipe connection b : Liquid return pipe connection 1591 c : Evaporator chilled water outlet d : Evaporator chilled water inlet e : Electrical supply Anti-vibration mounts Circuit 1 Circuit 2 Mass Kg LGN Figure a 1 1/8 1 3/8 1 3/8 1 5/8 2 1/8 1 5/8 Ø 2 1/8 b 7/8 7/8 1 1/8 1 1/8 1 1/8 1 1/8 1 3/8 1 1/8 1 5/8 a 1 3/8 1 5/8 Tube Ø 1 3/8 2 1/8 2 1/8 b 1 1/8 1 1/8 1 3/8 1 5/8 c - d G 1 1/4 G 1 1/2 G 2 G 2 1/2 PN 16 DN 80 PN 16 DN 100 PN 16 DN 125 A B C D E F G Empty In operation
19 DIMENSIONS DYNACIAT ILG A a : Water outlet internal circuit b : Water inlet internal circuit c : Water outlet external circuit d : Water inlet external circuit e : Electricity supply ILG Figure 1 2 Male connectors a - b c - d G 1 1/2 G 2 A Mass Kg Empty In operation
20 PIPING INSTALLATION EXAMPLE LG - LGP SERIES COOLING installation with water dry-cooler chilled water circuit hot water recovery circuit water filling expansion tank balance valve drain stop valve temperature controller air purge water filter (compulsory) flexibles (compulsory) thermometer wells water discharge 4 ways water valve accessible exchanger relief valve NOTE: the above piping diagram examples are indicative only and do not constitute installation details. 20
21 PIPING INSTALLATION EXAMPLE - ILG SERIES Indoor sensor COOLING / HEATING FLOOR REGULATOR and / or Outdoor sensor TERMINAL UNITS Floor C HYDRAULIC MODULE Safety valve + manometer B Flexible sleeves Filling Expansion vessel A A B Pump Safety valve + manometer Screen filter Internal circulation pump Screen filter Filling Buffer tank (option) Expansion vessel A Isolating valves VS Closed in summer WINTER B C Thermometer bags Adjusting valves Discharge SUMMER (The screen filter is positioned upstream from the wall pump if this pump does not accept the non-filtered water.) C Strainer valve Solenoide valve Outside network of water (pump with booster or city water) Wall or ground water NOTE: the above piping diagram examples are indicative only and do not constitute installation details. 21
22 PIPING INSTALLATION EXAMPLE - ILG SERIES COOLING / HEATING FLOOR and / or TERMINAL UNITS Indoor sensor Outdoor sensor REGULATOR Floor C HYDRAULIC MODULE Plancher Safety valve + manometer B Optional auxiliary heating Flexible sleeves Filling Expansion vessel A A B Pump Safety valve + manometer Screen filter Buffer tank (option) Internal circulation pump Screen filter Filling Expansion vessel Inlet circuit Return circuit A B C Isolating valves Thermometer bags Adjusting valves Filling product Geothermal sensor sensor under ground NOTE: the above piping diagram examples are indicative only and do not constitute installation details. 22
23 - LGP - ILG - LGN SERIES Installation recommendations Instructions for water quality criteria WARNING: A water filter (800 microns) must be mounted on the unit inlet by the installer. Correct and specified operation along with the assurance of reasonable life expectancy from the chiller-heater is significantly dependent on the water circuits, especially if the water quality is allowed to cause scaling, corrosion, the formation of algae or the growth of micro-organisms. The water quality must be thoroughly analyzed to ensure that it is suitable for use on the machine, and to establish that chemical treatment will be sufficient to maintain water quality at acceptable levels and if it will be necessary to install a softening/demineralisation process. This water analysis must establish the compatibility of the water used on the site with the following schedule of the different materials existing on the CIAT machine : - copper tubes 99.9% brazed with copper and silver filler, - depending on models, bronze threaded connexions or steal flange couplings, - exchangers with plates and connexions in stainless steal AISI brazed with copper and silver filler. Caution : if these instructions are not respected the warranty of the chiller will be voided. Lifting and handling operations Work with the best safety conditions for people during the lifting and handling operations. Follow the lifting instructions provided on the machine and the Installation, Operating, Commissioning and Maintenance instructions manual to the letter. Plan properly to ensure an accessible route to the place of installation before moving the machine. Always lift the unit vertically, under no circumstances must the machine be bent or put in a horizontal position. Location of the machine DYNACIAT units are designed to be positioned indoor in a technical plant. Frost protection must be foreseen. Great attention must be paid to leaving necessary space for maintenance access to the unit, including at the top. The machine has to be mounted on a level, non combustible flat and horizontal floor with a foundation capable of supporting the operation weight. Counter measures against the noise level of the auxiliaries, such as pumps, are recommended. Before installation, prevent, with the help of a sound specialist, the different possible sources of noise transmission, depending on the machine room and its design. It is NECESSARY to fit the pipework with rubber expansion joints (optional equipment). Venting of technical plant In accordance with the regulations on the installation site, a fresh air supply system may be installed to avoid dangerous situations or loss of comfort in the case of refrigerant leakage from the circuit of the machine. Installation of the accessories Several optional accessories can be delivered separately, to be mounted on the machine on site. Follow the instructions of the Installation, Operating, Commissioning and Maintenance manual to the letter. Field electrical wiring Follow the Installation, Operating, Commissioning and Maintenance instructions manual to the letter. All necessary instructions for electrical connections are detailed on the wiring diagrams attached to the unit. (They must be followed strictly) Connections must conform to good engineering practices and to norms and regulations in force. Field electrical wiring on site:. main electric power supply,. remote control of the machine (if necessary). free contacts informations (optional). It is important to note that the unit is not protected against lightning transients on the electrical supply. Accordingly, the installation must be fitted with apparatus to give adequate transient protection, and such devices must be incorporated in the field power electric box. 23
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationCondensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
More informationCool Design for Homes and Offices
AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners
More informationAIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
More informationINNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
More informationPower consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
More informationCooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
More informationHP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationWater Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
More informationNordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationCold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
More informationCLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
More informationRotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationCRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
More informationEngineering Specifications
Engineering Specifications NORDIC W-85-H-B-*S-PD Water to Water Heat Pump Single-Stage R134a Nominal 7.5 Ton With Double Wall Condenser for Domestic Hot Water Production Maritime Geothermal Ltd. P.O. Box
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationUR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationTWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationINSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
More informationCOOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
More informationYCAA-B AIR COOLED LIQUID CHILLER
YCAA-B AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 46 kw to 152 kw York YCAA-B twin refrigerant circuit air cooled liquid chillers are a compact design suitable for chilled water or
More informationMAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
More informationSECTION 23 64 10 AIR COOLED WATER CHILLERS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2
More informationNew Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
More informationDERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More informationmarine/bespoke split applications
split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments
More informationVisions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More informationD SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43
D SERIES MODULAR AIR-COOLED SCROLL CHILLER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 CONTENTS 1.MODELS LIST... 3 2.NOMENCLATURE... 3 3.FEATURES... 3 4.PRODUCT
More informationHot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
More informationCA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:
CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living
More informationSERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
More informationKompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
More informationTest Report issued under the responsibility of:
Test Report issued under the responsibility of: TEST REPORT EHPA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
More informationChilled Water Precision Air Conditioner For Critical Application
AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.
More informationDESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
More informationAIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
More informationSWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
More informationDesigned for multi-injector endurance testing, the
Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures
More informationAdsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationSWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
More informationSplit System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
More informationCOMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers
COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They
More informationSamurai range. Screw Type Water Chillers Cooling Only & Heat Pump Versions
Samurai range Screw Type Water Chillers Cooling Only & Heat Pump Versions CHILLERS Models Air cooled cooling only 40-400HP (112-1030kW) Air to Water heat pump 40-240HP (106-585kW) Water cooled cooling
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationVersati Air to Water Heat Pump
Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating
More informationMUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
More informationAE21-1319 R6 December 2013. Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE21-1319 R6
AE21-1319 R6 December 2013 Digital Capacity Control for Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions...2 Safety Icon Explanation...2
More informationSplit System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency
More informationThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationCOMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
More informationSENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps (20-100 GPM) 10 to 34 KW Stainless Steel Heaters
Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationTable V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
More informationLG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
More informationPANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
More informationSECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationA/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationIndoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
More informationYUTAKI S. Domestic Heating
YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance
More informationThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
More informationMaxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More informationProduct Data. Split System Cooling 22-1904-1F-EN. March 2015
Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationcatalog Single Package Vertical Air Conditioners and Heat Pumps
catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationice 3 FLUID TO FLUID HEAT PUMP
ice 3 FLUID TO FLUID HEAT PUMP SUBMITTAL DATA (888) 530-7713 P O Box 5, Wentworth, H 03282 Rev.3 (5-30-14) ice 3, IC-2040 Fluid-to-Fluid R-410a Heat Pump Engineering Guide Specifications General otes:
More informationRefrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale
More information