RAPID WATER CHILLER RAPIDMAC 50. ISO 9001 Cert. N 0412/2 OUR SYSTEMS COMPLY WITH DIRECTIVES 73/23 EEC - 89/336 EEC INSTRUCTION MANUAL
|
|
- Amelia Murphy
- 8 years ago
- Views:
Transcription
1 RAPID WATER CHILLER RAPIDMAC 50 ISO 9001 Cert. N 0412/2 OUR SYSTEMS COMPLY WITH DIRECTIVES 73/23 EEC - 89/336 EEC INSTRUCTION MANUAL Cod /2004
2
3 GB CONTENTS 1. GENERAL DOCUMENTATION 1.1 General information page Installation page Transport and handling page Unpacking - disposal of packing page General safety regulations page 5 2. INSTALLATION 2.1 Dataplate information page Positioning page Ambient temperature and air circulation page Electrical connections page Cooling connections page Overflow drain connection page Notes for the installer page Safety and control systems page Appliance disposal page 7 3. TECHNICAL CHARACTERISTICS page 8 4. PROGRAMMING INSTRUCTIONS 4.1 Keys page Self-test on start-up and microprocessor reset page Temperature set-point and management page 9 5. OPERATION 5.1 Description and general operating principles page Stand-by function, compressor/resistance management page Water heating function page Electric power failure page Rapidmac version with pump page Rapidmac manual version page ALARM MANAGEMENT, 6.1 List of other operating faults not indicated page MAINTENANCE AND CLEANING 7.1 Basic safety regulations page Cleaning the condenser page 13 3
4 GB 1. GENERAL DOCUMENTATION 1.1. General information This manual is an integral part of the product and provides all the information necessary for ensuring correct appliance installation, operation and maintenance. Read the manual carefully, making reference to it for machine operation. Keep the manual in a well-known place accessible to all authorised operators (installers, users and maintenance personnel) The machine has been constructed in compliance with the directives 73/23/CEE (low-voltage), 89/336/CEE (electromagnetic compatibility) and 98/37/CE (machines; for certain models only). The machine has been designed for professional applications only and should only be operated by qualified personnel. The appliance must only be used for its designed purpose, i.e. for preserving food products. The machine must not be used for products requiring constant temperature control and recording, such as heat-sensitive chemicals medicines - blood products The manufacturer declines all responsibility for any damage caused by incorrect or unreasonable machine use, such as: improper use by untrained persons technical modifications or operations not suited to specific models use of non-original or non-specific spare parts failure to follow the instructions given in this manual 1.2 Installation The machine must be installed by a specialised authorised technician in compliance with the instructions enclosed. (see installation drawing enclosed Fig.1) Fig mm 600 mm 1200 mm 600 mm 1.3 Transport and handling Loading or unloading the appliance from/onto the means of transport can be done with a lift truck or fork lift pallet truck equipped with forks at least half the length of the cabinet. Select the lifting equipment suited to the weight and overall dimensions of the packaged machine/components. All precautions must be taken to avoid damage to the appliance, in accordance with the warnings on the packaging (Fig.2). Fig.2 4
5 1.4 Unpacking Remove all cardboard, wood or other materials from the wood base on which the machine is set. Lift the machine with suitable means (e.g. lift truck), remove the wood base, then position the machine in the allocated site. After removing the packing, check the integrity of the appliance Remove the protective PVC film from all sides (Fig.3) Fig.3 Always wear protective gloves when handling packing material and the wood base. GB NB: Dispose of packing materials in compliance with disposal regulations applied in the country where the machine is to be installed. Never dispose of materials in the environment. 1.5 General safety regulations Failure to observe the recommendations made by the present manual will be at the entire responsibility of the machine user. The main safety regulations are as follows: - do not touch the machine with moist or wet hands or feet - never operate the machine while barefoot - do not insert screwdrivers, cooking utensils or any other object between the guards and moving parts - before performing cleaning or routine maintenance operations, disconnect the machine from the power supply by operating the main switch, also disconnecting the main knife-switch (if present) - never pull on the power cable to disconnect the machine from the power supply IMPORTANT!!! THESE OPERATIONS MUST BE PERFORMED BY A CERTIFIED INSTALLATION TECHNICIAN ONLY 2. INSTALLATION 2.1 Data plate information Check that the data specified on the plate correspond to the characteristics of the power supply (V, kw, Hz, no. phases and power available). The dataplate with appliance specifications is located at the rear exterior of the machine. 2.2 Positioning The machine must be installed and commissioned in complete compliance with current safety regulations, procedures and laws in the country of installation. The installation technician bears the responsibility of ensuring compliance with fire safety requirements; seek all necessary advice from the local fire-fighting authority Position the appliance in the allocated site Adjust the machine feet until the appliance is perfectly level. In the case of particularly heavy equipment, use appropriate lifting means 5
6 GB Wall-mounting bracket. Acting forces (binding reactions) in mounting bracket area: Fy= N Vertical force Fz= 747 N Horizontal traction (Fig.4) If the appliance is not levelled, this may impair correct operation. INFORMATION ON THE WALL USED FOR MOUNTING THE BRACKET IMPORTANT: The wall on which the bracket is to be fitted must be suitable to guarantee holding of the anchor plugs and adequate structural properties in relation to the loads applied as specified in the table below. As regards the civil structure (wall) the relative conditions added to the load applied by the bracket and device must fully comply with specifications of Italian Ministerial Decree no. 9 of January 1996 posizione mensola Bracket position struttura civile su cui si va a fissare la mensola Civil structure used to mount the bracket Fy Fz Fz in lower support area: Fz= 747 N Horizontal compression AVOID direct exposure to sunlight closed sites with high temperatures and poor air circulation Do not install the machine near sources of heat (fig. 5) Fig Ambient temperature and air circulation For air-condensed refrigerating units, the maximum ambient temperature for operation is 32 C. Correct operation cannot be guaranteed at higher temperatures. The machine may operate safely to a maximum temperature of 38 C. In any case, sufficient air interchange must be guaranteed 2.4 Electrical connections A differential thermal-magnetic circuit breaker complete with disconnecting switch must be installed upline of every appliance, complete with disconnect switch, in accordance with current regulations in the country of installation Connected electrical cables must correspond to the technical data (as specified on electrical drawings provided by the 6
7 installation technician) The earth wire must be correctly connected to an efficient earthing system. THE MANUFACTURER DECLINES ALL LIABILITY AND GUARANTEE OBLIGA- TIONS IN THE EVENT OF INJURY TO PERSONS OR DAMAGE TO EQUIP- MENT AND OBJECTS DUE TO INCOR- RECT INSTALLATION AND/OR FAILURE TO COMPLY WITH STANDING INSTAL- LATION REGULATIONS. 2.5 Water and cooling circuit connections See diagram enclosed Fig Overflow drain connection All models require a drain hose to collect overflow water. Fig.6 Symbol A B C D E F Description Overflow drain Domestic water inlet Electric power cable Chilled water outlet Control panel connection cable Remote control panel 2.7 Information for the installation technician Before starting up the machine, check that it has been correctly installed and commissioned (test report) 3. Check all mains wiring connections 6. Check the water connections 7. Ensure that the machine reaches the set temperature. Inform the customer of the exact use of the appliance, with specific reference to the use and requirements of the customer. Installation and commissioning must be carried out by authorised personnel 2.8 Safety and control systems Card protection fuses: Safety pressure switch: intervenes in the event of overpressure of the refrigerant circuit. Auxiliary component protection fuse Heating resistance safety thermostat 2.9 Appliance disposal Demolish and dispose of the machine in compliance with the regulations applied in the country of installation, particularly in regards to refrigerant gas and compressor lubricant oil. GB F A Fig.6 A B L I Symbol A B C D E F G H I L M N Description condenser Fan Liquid receiver Dryer filter Compressor Drain pump Litre counter (on manual version only) Water drain solenoid valve Water inlet solenoid valve Water circulation motor Evaporator coil Water level sensor Insulated tank C N H WATER INGRESSO INLET ACQUA Fig.7 D E F G CHILLED USCITA WATER ACQUA REFRIGERATA OUTLET 7
8 GB 3. TECHNICAL CHARACTERISTICS micro-relay card display-control card in remote panel located at a maximum distance of 5 metres. Software: 1. Water temperature control (cooling/heating) 2. Self-test and alarm management 3. Pump (and litre counter) control 4. Water inlet control. RAPIDMAC 50 Outside External width 1200 dimensions External depth 600 mm. External height 600 Insulation thickness 40 mm Tank and coil AISI 304 Control panel Remote 5 metre Net weight approx. 130 kg Exterior finish Grey plastic-coated steel- optional: AISI 304 steel exterior finish Accessories supplied as standard Wall mounting bracket TECHNICAL SPECIFICATIONS Electric power supply Condenser unit Refrigerant Water fittings Control panel function 400V / 3N / 50Hz Built-in R404a 3 1/4 GAS Temperature control Litre counter Water drain Cold/hot water selection NOISE LEVEL: Db detect from 1 m Db detect from 3 m 67 Db 64 Db 1200 mm 600 mm 300 mm 600 mm 8
9 4. PROGRAMMING INSTRUCTIONS GB Led Green verde Led Green Led verde Led 6 Led Green/Red verde/rosso Led KEYS: Pushbutton 1 = Increase (plus sign) Pushbutton 2 = Decrease (minus sign) (alarm shutoff) Pushbutton 3 = SET enables entry of SetPoint and access by password only. Pushbutton 4 = Cooling On/Off - Heating On/Off (if pressed and held, sets to Stand-By). Pushbutton 5 = Automatic water inlet filling disable On/Off Pushbutton 6 = Pump On/Off (litre counter control). 4.2 Self-test on start-up and microprocessor reset When the machine is switched on, all leds light up simultaneously on display. If the electronic card self-test is successful, a beep is activated for 5 followed by illumination of all leds. If a pushbutton is pressed during the self-test, an alarm is tripped. The self-test cycle can be repeated by turning the machine off and then on again. Press and hold down push-buttons and and then press, to display the text RES which resets the microprocessor, clears the memory and sets the default parameters. 4.3 Set-point (water temperature value entry). Press for 3 to show the factory setting of the set-point value, which flashes on display. The set-point value can be increased or decreased as required using the keys or and confirming the new water temperature setting by pressing. The machine is fitted with a differential between compressor start-up and shutdown: E.g. : set +10 C, diff. 2 C. The compressor is activated at +12 C and shut down at +10 C; The resistance is activated at +8 C and shut off at +10 C in heating mode. 9
10 GB 5. OPERATION 5.1 Description and general operating principles RAPIDMAC 50 is a water chiller equipped with a 50-litre tank with an immersed coil conveying the refrigerant (as well as a heating resistance). - control of the water temperature is by means of a sensor. Normally the display shows the water temperature. - Control of the maximum water level is by means of floats with on/off output. - A pump is available (optional) for rapid water drainage. - A pressure relief (safety) valve with on/off output is fitted - An internal litre counter (optional) is available (on manual version only) 5.2 Stand-by function, compressor/resistance management. When the machine is switched on (power delivered to card) after the self-test, the card sets to the status previously applied before power was shut off. Press key 4 to set the machine to cooling mode: the relative led 4 illuminates (green). (N.B. the compressor is started up after the set delay. During this interval led 4 flashes). - the display shows the temperature read by the water sensor - The water inlet solenoid valve is energised, if necessary, until the max. water level is reached. - Led 5 illuminates to indicate activation of the automatic filling cycle. - Once the max. water level is reached, the compressor, if the water temperature is above the set value, starts up. - The compressor shuts down when the set value is reached. - In these conditions led 4 remains lit to indicate that compressor operation is controlled by the thermostat. 5.3 Water heating function. Alternatively, if key 4 is pressed twice (double click) the machine sets to heating mode: the relative led 4 illuminates (red). - the display shows the temperature read by the water sensor - The water inlet solenoid valve is energised, if necessary, until the max. water level is reached. - Led 5 illuminates to indicate activation of the automatic filling cycle. - Once the max. water level is reached, the resistance is activated if the water temperature is below the set value. In any event the resistance cannot be activated unless the max. water level is reached. The resistance shuts off when the set value is reached. In these conditions led 4 remains lit to indicate that heater operation is controlled by the thermostat. - In both these operating modes, key 4 causes shutdown of the compressor or resistance and deactivation of led 4. - All the other functions (temp. on display, pump, etc.) remain enabled. If key 4 is pressed and held the machine exits the operating routine and sets to standby status. 10
11 GB I 5.4 Electric power failure In the event of a power failure, either momentary or prolonged, the machine must resume operation from the same conditions in which it stopped: if it was in stand-by phase it resumes this status; if the compressor, heating resistance or filling solenoid valve were in operation, these resume operation. However, this does not apply to the pump: even if in operation prior to the power failure, it remains off when the system is restarted. 5.5 Rapidmac version with pump a0) Pump and litre counter control Pump operation depends on the maximum pump activation time (3 ), after which the pump shuts down and delivery is stopped. If the pump is disabled the relative pushbutton is also disabled. a1) Litre counter disabled, Remote permissive disabled (machine without litre counter, without dispenser and without external dispenser/mixer but with pump): Press key 6 to illuminate the relative led and activate the pump outlet. Press key 6 again to turn off the led and shut down the pump. a2) Litre counter disabled, Remote permissive enabled (machine without litre counter, but with dispenser or external dispenser/mixer and with pump): When pressed once, key displays the number of litres already present in the memory, led 6 flashes (the value can be modified by means of the / keys) When pressed twice key 6 confirms the set value and activates the water outlet. At the end of the count of litres on output (shown on the display) the tank is emptied. 5.6 Rapidmac manual version Litre counter enabled, Remote permissive and pump disabled: (machine with litre counter, but without pump, dispenser or external dispenser/mixer) - In this configuration, if key 6 is pressed the litre counter is set to count the litres delivered: the display shows the value 00 and as soon as the pulses are sent from the litre counter, the count of litres delivered is started and shown on the display. - In any event, in the same configuration, as soon as the pulses are sent from the litre counter, the count of litres delivered is started and shown on the display. If key 6 is pressed this exits the count of the litres delivered. On subsequent delivery the litre counter will start from 00. After 30 seconds in which the litre counter no longer sends pulses, the display returns to the temperature reading. On closure of the remote permissive input for the dispenser/mixer, the pump outlet is activated and the led of key 6 illuminates. a3) Litre counter enabled: (machine with litre counter, but without dispenser or external dispenser/mixer and without pump). 11
12 GB 6. ALARMS, SIGNALS, BEEPER, AND SHUTOFF PUSHBUTTON MANAGEMENT 1 Alarm (AL1) temperature sensor faulty 2. Alarm (AL2) (Maximum pressure switch tripped) manual reset 3. Alarm (AL3) (no water or level sensor faulty) 4. Alarm t(al4) Membrane keypad faulty A NOTE ON ALARMS: During alarms, the beeper sounds and the display shows the type of alarm. The alarm message remains on the display even when the beeper has been silenced, until the cause has been eliminated In the case that more than one alarm has been activated, each one is alternately displayed. The alternating frequency of display enables reading of each text. When the beeper sounds, the user can stop it by means of the shutoff button. 6.1 List of other operating faults not indicated: FAULT CAUSE SOLUTION Compressor does not operate 1 - Power failure 1 - Check connection to power lines 2 - Thermal cutout trip 2 - Wait for automatic restart interval Condenser fan does not operate 1 - Power failure 1 - Check connection to power lines 2 - Fan fault 2 - Seek assistance from a service technician 3 - Air condenser dirty or clogged 3 - Clean the condenser Electronic card does 1 - Power failure 1 - Check connection to power lines not switch on 2 - Protective fuse broken 2 - Seek assistance from a service technician Compressor operates but does 1 - Shortage of refrigerant gas 1 - Seek assistance from a service technician not cool tank water 2 - Condenser soiled 2 - Clean the condenser Water pump does not operate 1 - Power failure 1 - Check connection to power lines 2 - Mechanical seizure 2 - Seek assistance from a service technician Litre counter does not operate 1 - Mechanical seizure 1 - Seek assistance from a service technician 2 - Electronic card faulty 2 - Seek assistance from a service technician Alarm AL1 on display 1 - Temperature sensor faulty with 1 - Replace sensor compressor shutdown Alarm AL2 on display 1 - Maximum pressure switch trip 1 - Seek assistance from a service technician 2 - Fan faulty 2 - Seek assistance from a service technician 3 - Condenser is soiled 3 - Clean the condenser Allarm AL3 1 - Water level sensor faulty 1 - Close the water filling valve Seek assistance (water outlet from overflow) from a service technician 2 - Water filling solenoid valve faulty 2 - Seek assistance from a service technician Allarm AL4 1 - Membrane keypad faulty 1 - Seek assistance from a service technician 12
13 7. MAINTENANCE AND CLEANING GB IMPORTANT!!! THESE OPERATIONS MUST BE PERFORMED BY A CERTIFIED INSTALLATION TECHNICIAN ONLY The information and instructions given in this section address all persons operating the appliance: the user, the maintenance technician and non-specialised personnel. Ensure that the electrical power to the system has been disconnected before carrying out any cleaning or maintenance work on the appliance. 7.1 BASIC SAFETY REGULATIONS To safely carry out all cleaning and routine maintenance operations, follow these rules. - do not touch the machine with moist or wet hands or feet. - never operate the machine while barefoot. - do not insert screwdrivers, cooking utensils or any other object between the guards and moving parts. - before performing cleaning or routine maintenance operations, disconnect the machine from the power supply at the master switch and by pulling out the plug. - Never pull on the power cable to disconnect the machine from the power supply. Removal of guards and safety devices for the purposes of routine maintenance is strictly prohibited. The manufacturer declines all responsibility for accidents caused by failure to observe the above regulation. 7.2 CLEANING THE CONDENSER 1) Progressive accumulation of dust on the front section of the condenser will gradually reduce efficiency of the cooling circuit. PERFORM THIS OPERATION ONLY AFTER THE APPLIANCE HAS BEEN SHUT DOWN Therefore make frequent inspections of the condenser and clean with a non-metal brush or vacuum cleaner. 2) At least once a year, check for deposits of lime scale on the cooling coil inside the container: this will avoid wasteful energy consumption and cooling output. To remove these deposits, use a solution of water and citric acid. 3) Drain the water from the tank if the machine is not used for prolonged intervals. 4) Periodically clean the water filter cartridge (optional). 5) IMPORTANT The condenser has sharp edges. Use protective gloves when cleaning. 13
14 Via del Lavoro, 9 - C.P. 172 I Castelfranco Veneto (TV) Italy Tel Fax tecnomac@castelmac.it Web-site: Cod /0-03/2004
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More informationDehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationAIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
More informationMeaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
More informationUSER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
More informationUse and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
More informationAir Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
More informationSi10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
More informationImportant Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
More informationSWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
More informationMAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
More informationVertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationCW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
More informationOverheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
More informationUser Manual: C100. 9052 Long Point Houston, TX 77055 888.827.1675 info@coolazone.com Facebook.com/CoolAZone Twitter.com/CoolAZone
User Manual: C100 9052 Long Point Houston, TX 77055 888.827.1675 info@coolazone.com Facebook.com/CoolAZone Twitter.com/CoolAZone w w w. c o o l a z o n e. c o m Table of Contents Table of Contents & How
More informationTMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
More informationINSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
More informationNewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
More informationUSER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
More informationSUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
More informationINSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationSplit Type Room Air Conditioner. KSWM units
OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
More informationAerona Air Source Heat Pumps
ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of
More informationSERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
More informationEnglish. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
More informationDoc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
More informationModel: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
More informationProgrammable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
More informationUSER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
More informationSERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationPORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
More informationOperating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
More informationREGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationContact Details. Please note that some of the contact details on this PDF document may not be current.
Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: customer.services@gdcgroup.co.uk
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
More informationService manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
More informationCRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
More informationInstruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
More informationTIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
More informationTHERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationDescriptive Technical Documentation. DTD no. 521-7135
Descriptive Technical Documentation - Model-dependent - DTD no. 521-7135 Model(s): PT 7135 C, PT 7136, PT 5135 C, PT 5136 14.10.2005, DE_en This information should not be duplicated or passed on without
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationNewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
More informationWALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
More informationUser manual. 086U6297 Rev. 9 EN
User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme
More informationNexus FS Point of Use Installation Guide
Nexus FS Point of Use Installation Guide Nexus FS POU Install Guide:12152011:rev-12152011 Technical Specifications Dimensions: Height: 43.5 Width: 11.65 Depth: 15 Weight: 34.39 LBS Electrical Specs: Voltage:
More informationAN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationCondensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
More informationInstallation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008
Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be
More informationOperating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
More informationDomestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +
MAKING MODERN LIVING POSSIBLE User Guide DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + www.heating.danfoss.com The English language
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationOperations Manual Blast Chiller
Operations Manual Blast Chiller ADE- 2039-A Page 1 of 14 Contents Page 1 What is the Adande System 3 2 Adande Technology Explained 3 3 EC Declaration of Conformity 4 4 Storage of Product 5 5 Operating
More informationNÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationCOOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
More informationIMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
More informationCarpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308. Vax model number: Version 1.0
VRS5W Powermax User Guide V1.0.qxd:V1.0 23/7/10 15:35 Page 1 Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308 Carpet Washer Vax model number: VRS5W instruction manual Version 1.0 Please read carefully
More informationUB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
More informationRefrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
More informationROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
More informationENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
More informationPLC Control Unit for a CSM-C Steam Compact Clean Steam Generator
3.635.5275.251 IM-P486-19 CH Issue 2 PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator Installation, Start-up and Operation Manual 1. Safety information 2. General product information 3.
More informationUser Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
More informationBench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
More informationWater Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
More informationPORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
More informationLK Electric Boiler - 4,5
LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered
More informationPlease keep these operating instructions in a safe place.
Please keep these operating instructions in a safe place. Dear Customer: Check this product for visible damage immediately upon receipt. Inform the shipper if there is any shipping damage. Note that damage
More informationBD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL
BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 2 Date : - 24/01/12 UNPACKING Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands
More informationwith MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationManual Code VR-197-0-0002
USE, MAINTENANCE AND INSTALLATION MANUAL AIR CONDITIONERS FOR ELECTRICAL ENCLOSURES Manual Code VR-197-0-0002 VZ1550 VZ1850 VZ1400 VZ2000 ABB SACE S.p.A. An ABB Group Company Automation and Distribution
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1301SAH/3, SWH/3, SRH/3 KM-1400SWH-M, SWH3-M KM-1601SAH/3, SWH/3, SRH/3 KM-1900SAH/3, SWH/3, SRH/3 KM-2100SWH3, SRH3 KM-2500SWH3, SRH3 KMH-2000SWH/3,
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationSHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
More informationINSTALLATION MANUAL. Address card EKAC10B
INSTALLATION MANUAL 88 44 µchiller compact 70 64 4a 4b G G0 power supply G G0 power supply 50 5 50 5 4a 4b 5a 5b 4 5a 5b Installation manual READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO
More informationMICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
More information