MGE UPS Communication

Size: px
Start display at page:

Download "MGE UPS Communication"

Transcription

1 MGE UPS MGE UPS SYSTEMS has developed a comprehensive, simple and coherent range of products for power supply management for servers and other systems requiring power protection. This range provides 2 main functions: > connecting UPS systems to an IP network > active supervision of the whole system.

2 Network Management Card Network Management Card Embedded management of UPSs protecting servers and networking equipment. > Event logging: Pinpoint the timing and sequence of events leading up to an incident with the event log. > Notification: Network administrators can solve problems remotely before they impact availability. > Scheduling: Customize shut down and reboot of connected equipment and UPSs. > Flash upgradeable firmware: Install maintenance releases of firmware remotely using FTP. > Remote UPS management: Enable management of your UPS by connecting it directly to the network. Network management card with MODBUS/JBUS Embedded management of UPSs protecting servers and networking equipment. > Event logging: Pinpoint the timing and sequence of events leading up to an incident with the event log. > Notification: Network administrators can solve problems remotely before they impact availability. > Scheduling: Customize shut down and reboot of connected equipment and UPSs. > Flash upgradeable firmware: Install maintenance releases of firmware remotely using FTP. > Remote UPS management: Enable management of your UPS by connecting it directly to the network. Network management Teleservice Card Directly connect the UPS to a computer network, while simultaneously operating as a Web server and SNMP agent. > Event logging: Pinpoint the timing and sequence of events leading up to an incident with the event log. > Notification: Network administrators can solve problems remotely before they impact availability. > Scheduling: Customize shut down and reboot of connected equipment and UPSs. > Flash upgradeable firmware: Install maintenance releases of firmware remotely using FTP. > 24-hour monitoring: Experienced remote monitoring professionals work non-stop to provide 24-hour monitoring of the company's physical infrastructure. As a second set of eyes, they help to diagnose problems before they become critical. > Remote UPS management: Enable management of your UPS by connecting it directly to the network.

3 UPS Cards JBUS/MODBUS communication card The JBUS/MODBUS communication card provides UPS and STS (Static Transfer Switch) data. > Data Transfer: The card transfers data via MODBUS/JBUS standard protocol. STS Web card Upsilon/Epsilon STS can be monitored by the STS web card. > Remote UPS management: Enable management of your UPS by connecting it directly to the network. Utalk basic Acquisition card The acquisition card is an optional part of the MultiSlot module. Using the proprietary U-Talk or Basic protocols (dry contacts), it acquires measurements, status information and alarms from the UPS and transmits the data to the I2C bus of the MultiSlot. > UPS Status Checking: Continuously checks UPS status to verify current condition

4 UPS Accessories Environment Sensor for Network Management Card Environment Sensor (ES) monitors temperature, humidity, and the state of two contacts. > Temperature monitoring - Changes in temperature are reported via the user interface or . > Customizable input contacts - Monitor conditions from third party devices that have contact closures > Humidity monitoring - Changes in humidity are reported via the user interface or . Alarm relays electrician communication card The card controls six output relays depending on the operating status of the UPS. It also receives signals on the two SELV inputs (this function is available only in programmable mode). > Customizable input contacts: Monitor conditions from third party devices that have contact closures. > Customizable Output Relays: Control the output from third party devices via output relays. KIT Network management link The Network Management Link kit allows connection of 6000, 9000, EPS 6000, 7000, 8000 or Comet UPSs to the network. > UPS Status Checking: Continuously checks UPS status to verify current condition

5 UPS Accessories 2 Utalk / Basic ports communication card Provides two communication ports that may be configured for Serial/RS232 Port (U-Talk) and Basic (AS400-type dry contacts). Dry Contact inputs: User assignable inputs allow other equipment alarms to be monitored through the power system controller. Serial connectivity: Provides management of the UPS via a serial port. PowerServices TM TelPac PowerServices TM TelPac enables connection of one or more products to the MGE UPS SYSTEMS Teleservice center via an analog telephone line. > 24-hour monitoring: Experienced remote monitoring professionals work non-stop to provide 24-hour monitoring of the company's physical infrastructure. As a second set of eyes, they help to diagnose problems before they become critical. PowerServices TM TelPac GALAXY PowerServices TM TelPac enables connection of one or more products to the MGE UPS SYSTEMS Teleservice center via an analog telephone line. > 24-hour monitoring: Experienced remote monitoring professionals work non-stop to provide 24-hour monitoring of the company's physical infrastructure. As a second set of eyes, they help to diagnose problems before they become critical. Multislot IEC Multislot Australia Multislot NEMA Multislot DIN Extension module for communications card. > MGE UPS Extension Accessory: Expansion module for communication card.

6 UPS Compatibility PW 1000P W EPS 6000 EPS 7000 EPS Upsilon 8000 Comet STS JBUS/MODBUS Card Utalk Basic Acquisition Card Alarm Relays Electrician Card Network Management Card PowerServices TM TelPac Kit Network Management Link X PowerServices TM TelPac GALAXY Network Management Card with MODBUS/JBUS Network Management Teleservice Card Environment Sensor for Network Management Card X X STS Web Card X 2 Utalk / Basic Ports Card Multislot DIN Multislot IEC Multislot Australia Multislot NEMA 66071

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

Remote Monitoring Unit SC8100. Monitoring Unit SC8100 Monitoring Unit SC8100 Remote Monitoring Unit SC8100 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all

More information

Rack Power Distribution

Rack Power Distribution The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:

More information

Environment Sensor - 66846

Environment Sensor - 66846 NMC Transverse - 66074 Environment Sensor - 66846 Network 34003676EN/HA Page 1/81 Table of Contents 1 MGE NETWORK SOLUTION 5 1.1 INTRODUCTION 5 1.1.1 Connecting the UPS / STS to the Network 5 The Network

More information

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no

More information

Connectivity. PowerShield 3. Communications Software

Connectivity. PowerShield 3. Communications Software Connectivity 0800 978 8988 PowerShield 3 Communications All the trademarks indicated are the property of their respective owners. GRAPHIC MONITORING OF UPS AND Environmental Sensors STATUS PowerShield

More information

Software and accessories

Software and accessories Software and accessories PowerShield 3 SHUTDOWN Software PowerShield 3 is available for download at www.riello-ups.com Highlights GRAPHIC MONITORING OF UPS AND ENVIRONMENTAL SENSOR STATUS PowerShield 3

More information

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara

More information

Power Supply SNMP Interface User Manual for SRL versions

Power Supply SNMP Interface User Manual for SRL versions Power Supply SNMP Interface User Manual for SRL versions SNMP-L User Manual 150722(firmware 02r_a12).doc Table of Contents 1. INTRODUCTION... 3 1.1 Default IP Address... 3 2. LOGIN... 4 3. MONITORING &

More information

Rack Power Distribution. Worldwide

Rack Power Distribution. Worldwide Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data

More information

Network Management Card

Network Management Card Network Management Card Installation manual IP= MAC=00E0D8FF855E Reset 100 10 data Card Settings 1 2 RS232 Download ETHERNET RS232 66074 34003641EN/AG - Page 1 1 2 1 2 Quick start ASI or STS U-Talk ASI

More information

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry. IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input

More information

Technical Overview CM-16 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk

Technical Overview CM-16 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk Technical Overview CM-16 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk Need a lot of remote sensors in a rack mount? The CM-16 has web access, graphing, and alarm alerts sent by

More information

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and

More information

Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM

Section 16935 TELEPHONE AUTOMATIC DIALER SYSTEM Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular

More information

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System V RICONTROL M O N I T O R I N G S O L U T I O N S TM INFRASTRUCTURE MANAGEMENT SOLUTIONS Varicontrol-P The Integrated Rack Management System CONTROLLERS Varicontrol-P2, Varicontrol-P4 and Varicontrol-P6

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Minislot 66244. Transverse 66074. Environment Sensor 66846

Minislot 66244. Transverse 66074. Environment Sensor 66846 Minislot 66244 Transverse 66074 Environment Sensor 66846 Management Card 34003676EN/BB Page 1/76 Table of Contents 1 MGE NETWORK SOLUTION 5 1.1 INTRODUCTION 5 1.1.1 Connecting the UPS to the 6 The Management

More information

AXIS 262+ Network Video Recorder

AXIS 262+ Network Video Recorder 31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,

More information

Ambient Temperature In Range Probe X

Ambient Temperature In Range Probe X List of Events This section lists all events that are written to the Event Log. Some of these events can be configured through the Configuring Events to Take Actions page, and these are listed in the first

More information

securityprobe 5E Standard

securityprobe 5E Standard securityprobe 5E Standard securityprobe 5E Standard Monitor the physical environment and receive alerts of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke,

More information

INTELLECT TM Software Package

INTELLECT TM Software Package AxxonSoft INTELLECT TM Software Package Quick Start Guide Version 1.0.0 Moscow 2010 1 Contents CONTENTS... 2 1 INTRODUCTION... 3 1.1 Document purpose... 3 1.2 Purpose of the Intellect software package...

More information

Product Guide CM-Relay

Product Guide CM-Relay Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL. Overview CM-Relay combines climate monitoring with remote relay

More information

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5

Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5 Technical Manual (TLT-2H GPS/GSM Vehicle Tracker) V1.5 Product main features Real-time SMS query coordinates time position, Phone Position active help feature speed alarm function historical data uploading

More information

HP UPS Management Module Overview

HP UPS Management Module Overview Overview The enables you to monitor and manage power environments through comprehensive control of HP UPSs. The can support either a single UPS configuration or provides additional power protection with

More information

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS NetAgent (connection through RJ45 LAN network) NetAgent is an SNMP (Simple Network Management Protocol) interface that enables connection and configuration

More information

SNMP Web Management. User s Manual For SNMP Web Card/Box

SNMP Web Management. User s Manual For SNMP Web Card/Box SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...

More information

Network Management Card & Modbus/Jbus 66123 User Manual

Network Management Card & Modbus/Jbus 66123 User Manual Network Management Card & Modbus/Jbus 66123 User Manual 66124 User Manual For Galaxy 7000 UPS and SSC unit Network Management Card & Modbus/Jbus 34022321XT indice :AE Page 1/98 Contents 1 MGE GALAXY 7000

More information

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management My2B GSM/GPRS Datalogger with Alarm Management 100% Made & Designed in Italy My2B GSM/GPRS Datalogger with Alarm Management MY2B ( Standard / Datalogger) is a GSM / GPRS telecontrol unit for home & building

More information

Technical Overview CM-2 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk

Technical Overview CM-2 Climate Monitor. Get yours direct at: 01491 410913 www.theclimate.co.uk Technical Overview CM-2 Climate Monitor Get yours direct at: 01491 410913 www.theclimate.co.uk The importance of effectively monitoring IT environments has never been greater. There are a multitude of

More information

HWg-STE HWg-STE PoE MANUAL

HWg-STE HWg-STE PoE MANUAL HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.

More information

DPS Telecom Your Partners in Network Alarm Management

DPS Telecom Your Partners in Network Alarm Management DPS Telecom Your Partners in Network Alarm Management Techno Knowledge Paper Problem: Unable to Setup FTP Server on T/Mon IAM Platform: T/Mon IAM, v4.2b and above Failure to backup your data can cost you

More information

BlackHawk for MAC Software User Guide

BlackHawk for MAC Software User Guide BlackHawk for MAC Software User Guide Products: BLK-DH2 Series and BLK-HD Series DVRs Please read this manual before using your software, and always follow the instructions for safety and proper use. Save

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview Overview The enables you to monitor and manage power environments through comprehensive control of HP UPSs. The can support either a single UPS configuration or provides additional power protection with

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Communication and connectivity the ideal solution for integrated system management and data integrity

Communication and connectivity the ideal solution for integrated system management and data integrity the ideal solution for integrated system management and data integrity The solution for Management solutions > Data centre > Emergency applications > Offices > Service industries > Industry > Telecommunications

More information

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6 Contents Introduction 1 Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5 Initial Configuration Requirements 6 Overview 6 Setup Wizard 7 Status, Alarm,

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Square D Model 6 Motor Control Centers

Square D Model 6 Motor Control Centers Square D Model 6 Motor Control Centers with Ethernet Communications What is industrial Ethernet? Over the past few years the use of Ethernet communications has spread into every corner of the business

More information

Choosing Powerware Network adapters

Choosing Powerware Network adapters Choosing Powerware Network adapters In today s IT environment the dominating communication channel is TCP/IP networking. Physically the networks are almost exclusively based on Ethernet (IEEE 802.XX) platform.

More information

Panduit Infrastructure Management Software for Data Centers and Enterprises

Panduit Infrastructure Management Software for Data Centers and Enterprises Panduit Infrastructure Management Software for Data Centers and Enterprises SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features: Simple

More information

Zertico Rack Monitoring Unit

Zertico Rack Monitoring Unit Zertico Rack Monitoring Unit Typical applications of Zertico Monitoring devices: - Monitoring of IT infrastructure (e.g. data center) - Monitoring of technical rooms in branch offices - Remote monitoring

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

I2C PRESSURE MONITORING THROUGH USB PROTOCOL. I2C PRESSURE MONITORING THROUGH USB PROTOCOL. Product Details: To eradicate human error while taking readings such as upper precision or lower precision Embedded with JAVA Application: Technology Used:

More information

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications Page 1 / 14 Technical specifications Page 2 / 14 SUMMARY 1. GENERAL OVERVIEW 1.1 MIOS and the remote management 1.2 The MIOSBOX range 1.3 Synthesis of MIOSBOX s specificities 2. DETAILED PRESENTATION OF

More information

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700 Tel: +90-216 466 84 60 Fax: +90-216 364 65 65 [email protected] http://www.datakom.com.tr APPLICATION NOTE Ethernet Configuration Guide for D-500 D-700 PRODUCTS AFFECTED: D-500 / D-700 WRITTEN BY:

More information

Network Management Card

Network Management Card Network Management Card AP9617 AP9618 AP9619 Installation and Quick-Start Manual How to Avoid Equipment Damage Disconnect UPS power You do not need to turn off a Symmetra or a Silcon model UPS to install

More information

Semaphore T BOX Applications in Data Center Facilities

Semaphore T BOX Applications in Data Center Facilities Semaphore T BOX Applications in Data Center Facilities Introduction Data centers must reliably provide 24/7/365 operation. For automation and monitoring of the facility, use of a rugged, reliable RTU is

More information

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2 NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

Eaton epdu. Intelligent and flexible power distribution

Eaton epdu. Intelligent and flexible power distribution Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require

More information

! encor e networks TM

! encor e networks TM ! encor e networks TM Version A, March 2008 Document Part Number 16568.0000 Copyright 2008 Encore Networks, Inc. All rights reserved. BANDIT II and BANDIT III Document Set List of Modules Note: For lists

More information

UPSMON PRO Linux --- User Manual

UPSMON PRO Linux --- User Manual UPSMON PRO Linux --- User Manual Version : 2.1 *Attention : root authority is necessary to execute at Linux here AA. UPSMON PRO Install 2 BB. UPSMON PRO Start 3 CC. UPSMON PRO Status 6 DD. UPSMON PRO Config

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments The MSITel module family allows your ground console to be everywhere while balloon experiments run everywhere MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

More information

Natural Gas Well Automation using Kingfisher RTU Products

Natural Gas Well Automation using Kingfisher RTU Products Natural Gas Well Automation using Kingfisher RTU Products Introduction Semaphore s Kingfisher RTU products have been applied to well site installations throughout the world. The product family includes

More information

Medical Vacuum Systems-PXMI

Medical Vacuum Systems-PXMI Medical Vacuum Systems-PXMI Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

Configuring PROFINET

Configuring PROFINET CHAPTER 9 This chapter describes how to configure the PROFINET feature on the Cisco IE 3000 switch. Understanding PROFINET, page 9-1, page 9-4 Displaying the PROFINET Configuration, page 9-5 Troubleshooting

More information

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master

More information

How To Log On... 13 Main Screen... 16 Control Console Menus... 19

How To Log On... 13 Main Screen... 16 Control Console Menus... 19 Contents Introduction 1 Product Description.......................................... 1 Internal Management Features.................................. 4 How to Recover from a Lost Password...........................

More information

Alarm Messages... 15 Clearing the Hardware Alarms... 16. How to Log On... 17 Summary Page... 21 Navigation Menu... 24

Alarm Messages... 15 Clearing the Hardware Alarms... 16. How to Log On... 17 Summary Page... 21 Navigation Menu... 24 Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading

More information

securityprobe5es -X20

securityprobe5es -X20 securityprobe5es -X20 v.100.00x securityprobe5es -X20 will monitor the physical environment and alert you of any disturbances, such as unauthorized intruders, security breaches, high temperatures, smoke,

More information

Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7

Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7 PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped

More information

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD

More information

F2103 GPRS DTU USER MANUAL

F2103 GPRS DTU USER MANUAL F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS Kokii BatteryDAQ BMS Battery Analyzer Battery DAS Updated: October 2008 Caution: High Voltage Exists on Battery Power and Sampling Connectors! Please refer to device installation and operation manual for

More information

Fortinet Network Security NSE4 test questions and answers:http://www.it-tests.com/NSE4.html

Fortinet Network Security NSE4 test questions and answers:http://www.it-tests.com/NSE4.html IT-TESTs.com IT Certification Guaranteed, The Easy Way! \ http://www.it-tests.com We offer free update service for one year Exam : NSE4 Title : Fortinet Network Security Expert 4 Written Exam (400) Vendor

More information

Ultra Thin Client TC-401 TC-402. Users s Guide

Ultra Thin Client TC-401 TC-402. Users s Guide Ultra Thin Client TC-401 TC-402 Users s Guide CONTENT 1. OVERVIEW... 3 1.1 HARDWARE SPECIFICATION... 3 1.2 SOFTWARE OVERVIEW... 4 1.3 HARDWARE OVERVIEW...5 1.4 NETWORK CONNECTION... 7 2. INSTALLING THE

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

User s Manual Network Management Card

User s Manual Network Management Card User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1 SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable

More information

MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz)

MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz) MAX-306M1 Series Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz) WiMAX MIMO Outdoor Simple CPE Firmware v3.70 Edition 2, 12/2009 DEFAULT LOGIN DETAILS IP Address: Username: http://192.168.1.1 admin

More information

Technology & Evolution

Technology & Evolution Technology & Evolution WebGate is an innovative product that allows all Carel controllers to be connected to any Ethernet -TCP/IP network. These protocols have seen enormous development and diffusion in

More information

EMS. Trap Collection Active Alarm Alarms sent by E-mail & SMS. Location, status and serial numbers of all assets can be managed and exported

EMS. Trap Collection Active Alarm Alarms sent by E-mail & SMS. Location, status and serial numbers of all assets can be managed and exported EMS SmartView TM Superior Design with Real-Time Monitor and Control Trap Collection Active Alarm Alarms sent by E-mail & SMS Network Topology Network Element Discovery Network Element Configuration Location,

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

FLYPORT Wi-Fi 802.11G

FLYPORT Wi-Fi 802.11G FLYPORT Wi-Fi 802.11G System on module 802.11g WIFI - Infrastructure mode - softap mode - Ad hoc mode Microchip PIC 24F 16 bit processor Microchip MRF24WG0MA/MB - Native WiFi 802.11g transceiver - PCB

More information

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY

FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY FVSU-33201301 REPAIR & UPGRADE FIBER OPTIC 280000-1 SECTION 280000 FIRE ALARM SYSTEM CONNECTIVITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Addressable interface

More information

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM Poseidon 3265 starting guide Poseidon 3265 Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM 1) Connecting Poseidon 3265 1.1) Check DIP switches settings. For installation

More information

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution. Sensor Control... Control... Sensor Control... Access securityprobe 5E Standard securityprobe 5E Standard Monitor the physical environment and receive alerts of any disturbances, such as unauthorized intruders,

More information

CenterMind P+ Solution for efficient power management

CenterMind P+ Solution for efficient power management CenterMind P+ Solution for efficient power management Overview Over last decade DC become significant power consuming facilities Information Technology Equipment (ITE) continue to increase computing capabilities

More information

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield: the following parts are needed to test the unit: Arduino UNO R3 Arduino Wifi shield And reciever 5V adapter Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the

More information

Network Management Card

Network Management Card www.eaton.com Network Management Card User manual Network Management Card User Manual 34003991EN/EC Page 1/118 Contents 1 EATON NETWORK SOLUTION 5 1.1 GENERAL PRESENTATION 5 1.1.1 Connecting the UPS to

More information

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment AUROLEX Plug and Play Monitoring The best ways to achieve a cleaner, safer environment R AUROLEX MONITORING SYSTEEM The flexible Aurolex Monitoring System offers users the ability to simultaneously measure

More information

Simple Blaster Wi-Fi SETUP GUIDE. Simple Blaster Wi-Fi. This document describes how to set up Simple Blaster - Wi-Fi.

Simple Blaster Wi-Fi SETUP GUIDE. Simple Blaster Wi-Fi. This document describes how to set up Simple Blaster - Wi-Fi. Simple Blaster Wi-Fi SETUP GUIDE Simple Blaster Wi-Fi This document describes how to set up Simple Blaster - Wi-Fi. Released October 2015. Copyright 2015 by Roomie Remote, Inc. All Rights Reserved. SimpleControl.com

More information

Acquiring i data from the field level l to a SQL database

Acquiring i data from the field level l to a SQL database M2M SQL Connector - a Turnkey Solution Dt Data Acquisition Data Logging Transmission SQL Database Acquiring i data from the field level l to a SQL database M2M Data Management 5 Steps: 1. Data Acquisition

More information

Introducing Tripp Lite s PowerAlert Network Management Software

Introducing Tripp Lite s PowerAlert Network Management Software Introducing Tripp Lite s PowerAlert Network Management Software What Can It Do For You? Improve the accuracy and efficiency of the network operations staff in the context of power and environmental management

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

UPiS - Uninterruptible Power intelligent Supply

UPiS - Uninterruptible Power intelligent Supply UPiS - Uninterruptible Power intelligent Supply www.pimodules.com Introduction The UPiS is an Advanced Powering add-on Module for the RaspberryPi that adds a wealth of additional features to the powering

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents

More information

INTRODUCTION FEATURES OF THE ICM

INTRODUCTION FEATURES OF THE ICM INTRODUCTION The ICM, Internet Control Module, is a remote controller device accessible via the Internet that allows operational access to the IPS (and other base units available). Through the ICM you

More information

What is our purpose?

What is our purpose? Who we are? Since 1995 we have become one of the largest suppliers of electronic automotive accessories and telemetry devices in the Baltic States. Baltic Car Equipment is investing extensively into R&D

More information

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE INTRODUCTION This technical note provides simple procedures that can be performed in the field to help identify and correct the cause

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information