Q7130A, Q7230A, Q7330A Modutrol IV Interface Modules

Size: px
Start display at page:

Download "Q7130A, Q7230A, Q7330A Modutrol IV Interface Modules"

Transcription

1 Q70A, Q70A, Q70A Modutrol IV Interface Modules EATURES INSTALLATION INSTRUCTIONS Q70A APPLICATION Q70A Q70A The Q70, Q70, and Q70 Modutrol IV Interface Modules are used with Series 90 Modutrol IV Motors (M9XX) for conversion to electronic (Series 70) control. Mounts inside the wiring box of any Series 90 Modutrol IV Motor (M9XX models). Module protected from weather by the Modutrol IV NEMA wiring box. Mates to quick-connect terminals in motor wiring box and provides screw terminals for control wiring connections. eatures solid state circuitry with surface mount components. Plastic enclosure provides easy handling and protection for circuitry. Q70A provides selectable voltage range (-7, 6-9, or 0.-. Vdc). Adapts M9XX Modtrol IV Motor to function as M7XX model for M7H,J, M7D, M7G,P replacements. Includes reversing switch to allow replacement of electrically normally open or electrically normally closed motors. Q70A provides current or voltage control (-0 ma and -0 Vdc) with adjustable zero and span. Adapts the M9XX Modutrol IV Motor to function as M7XX model for M7S,T,Y or M7S,T,Y replacements. Includes reversing switch to allow replacement of electrically normally open or electrically normally closed motors. Q70A is an interface to W96 and W9 controls. Adapts the M9XX Modutrol IV Motor to function as M7XX model for M7D, M7A, M7A replacements. Put Bar Code Here 6--07

2 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES SPECIICATIONS IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed. Input Impedance: Q70A: >00k ohms. Q70A: voltage input >00k ohms; current input 67 ohms. Temperature Rating: -0 to +0 [-0 C to + 66 C]. Dimensions: See ig.. Models: Q70A Modutrol IV Interface Module: Used with M9XX Modutrol IV Motor to replace M7XX Motor applications. Module controls only one motor. See Table. Q70A Modutrol IV Interface Module: Used with M9XX Modutrol IV Motor to replace M7XX Motor applications. Module controls only one motor. See Table. Q70A Modutrol IV Interface Module: Used with M9XX Modutrol IV Motor to replace M7XX Motor applications. Module controls only one motor. See Table. -9/6 (9) -/ (96) Electrical Ratings: -/6 (78) M7 Input Voltage: Vac, 0/60 Hz. Power Consumption: VA. ig.. Q70,Q70,Q70 Modutrol IV Interface Module dimensions in in. (mm). a b Table. Interface Module unction/application Chart. And Replaces This Model Provides Interface or These Old Style Motors a When Used with Series 90 Models: Q70A Selectable voltage ranges: -7, 6-9, or 0. to. Vdc M7H M96D009 M7J M7D b M98D0 M7G M98A08 Q70A Adjustable zero and span, voltage or current M98D0 M7S M98D0 control (includes -0 ma and -0 Vdc). M7T M7Y M7S M98D00 M7T M7Y Q70A W96 or W9 control interface. M7D M96D009 M7A M98D0 M7A M98D00 Refer to customer.honeywell.com for cross-reference details. M7D07 and M7D0 do not apply. 6-07

3 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES INSTALLATION When Installing This Product. Read these instructions carefully. ailure to follow them could damage the product or cause a hazardous condition.. Check the ratings and description given in this specification to make sure the product is suitable for your application.. Installer must be a trained, experienced service technician.. After installation is complete, check out product operation as provided in these instructions.. Excessive force can damage potentiometer controls. Use a small screwdriver when adjusting all potentiometers located on the unit. CAUTION Disconnect power before installation to prevent electrical shock or equipment damage. IMPORTANT: or ease of adjustment, make all stroke and auxiliary switch adjustments before installing the interface module. After installation, access to the stroke adjust cams and auxiliary switches inside the motor is restricted. or complete details on performing these adjustments, refer to the specification sheet packed with the Modutrol Motor. Installing Terminal Block CAUTION When installing the terminal block on the motor quick connects, push the board straight down. Rocking or tilting of the board can damage the electrical connectors and result in an inoperative wiring module.. Disconnect power from the M9XX Modutrol IV Motor to prevent electrical shock or equipment damage.. Remove wiring box cover from the motor by removing four screws.. Disconnect all field wiring from the motor.. If motor has an internal transformer, make sure transformer is not powered and disconnect secondary wires from T and T terminals. Clip quick-connect terminations from transformer secondary (brown) wires. Trim /8 to / in. ( to 6 mm) of insulation from the ends of the wire. Tin wire ends with solder.. Plug terminal block onto quick-connect terminals inside wiring box. 6. Connect field wiring to screw terminals on terminal block. See ig.,, and 9 for terminal designations. Trim wire ends neatly and tin with solder. 7. Position circuit module and secure. SETTINGS AND ADJUSTMENTS Module Adjustments Q70A Adjustments (ig. ) The Q70A provides selectable range, two-wire voltage control (-7, 6-9 or 0.-. Vdc). It includes a clockwise/ counterclockwise (cw/ccw) switch for replacing electrically normally open or electrically normally closed motors. Please remove film from CW/CCW switch before use.. Set Mod IV motor pots both CW or both CCW for your application. Use the checkout procedure in Table to ensure proper motor function.. Select desired voltage range using the three-position switch reference chart for dip switch settings (see ig. ).. Select desired rotation. Select cw for electrically normally closed (motor drives clockwise, as viewed from power end, to open with an increase in control signal). Select ccw for electrically normally open (motor drives counterclockwise, as viewed from power end, to close with an increase in control signal) (default switch position is clockwise).. See ig. for typical system wiring.. Set controller to drive motor to fully open position and then to fully closed position to check for proper operation. Q M96 ig.. DIP switch reference. 6-07

4 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES T T C+ A L (HOT) L V TRANSORMER C T R T + MODULATING DC VOLTAGE SOURCE CCW CW ig.. Q70A terminals and adjustments. M7 POWER SUPPLY. ADD DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. OPTIONAL NORMALLY OPEN SWITCH. WITH CCW SELECTION, WILL RUN TO ULLY CLOSED; WITH CW SELECTION WILL RUN TO ULLY OPEN WHEN THIS SWITCH CLOSES (AS LONG AS POWER IS APPLIED TO T, T TERMINALS). OPTIONAL NORMALLY CLOSED SWITCHES. INE SILVER OR DRY CONTACTS REQUIRED. WITH CCW SELECTION, WILL RUN TO ULLY OPEN; WITH CW SELECTION, WILL RUN TO ULLY CLOSED WHEN SWITCH IN EITHER C OR R LEAD IS OPENED. M0C ig.. Typical system wiring for Q70A Interface Module and M9XX Modutrol Motor. Table. Q70A/M9XX Checkout Procedure. Step Proper Motor Response Switch in Clockwise Position Switch in Counterclockwise Position. Open terminal C or R. Motor runs closed (fully ccw). Motor runs open (fully cw).. Jumper terminals C and. Motor runs fully open (fully cw). Motor runs fully closed (fully ccw).. Remove either T terminal or disconnect power supply. Spring return motors return to normal spring position (fully ccw for mechanically normally closed motors; fully cw for mechanically normally open motors). Q70 Adjustments (ig. and Table ) The Q70A provides adjustable range (zero and span) for two-wire current or voltage control. Separate potentiometers are provided on the circuit module for adjusting the zero point and the span. It includes a cw/ccw switch for configuring the motor to rotate clockwise or counterclockwise with an increase in control signal.. Set Mod IV motor pots both CW or both CCW for your application. Use the checkout procedure in Table to ensure proper motor function.. Verify that the zero potentiometer is fully clockwise and that the span potentiometer is fully counterclockwise. (Do not exceed the stop point of the potentiometer.). Select desired rotation direction [cw (electrically normally closed) is the most common]. The following directions apply for the clockwise setting. or counterclockwise setting, reverse open and closed, and reverse clockwise and counterclockwise. Remove film on switch before use. (Default switch position is CW.). See ig. 7 and 8 for typical system wiring.. or current control, connect the current input signal to I+ (screw terminal ) and COM (screw terminal ). or voltage control, connect the voltage input signal to V+ (screw terminal ) and COM (screw terminal ). 6. Set the controller to output the signal required to drive the motor to the closed position. Wait for the motor to stop driving closed. 7. Turn the zero potentiometer slowly counterclockwise until the motor starts to open. 8. Turn the zero potentiometer slowly clockwise until the motor is fully closed. This is defined as the zero setting. 9. Set the controller to output the signal required to drive the motor to the fully open position. Wait for the motor to stop driving open. 0. Turn the span potentiometer slowly clockwise until the motor starts to drive closed. The difference between the fully open position signal and the fully closed position signal is defined as the operating span.. Recheck the fully closed position and readjust the zero potentiometer, if necessary. (Turn the zero potentiometer clockwise to close the motor and counterclockwise to open the motor.) 6-07

5 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES. Recheck the fully open position and readjust the span potentiometer, if necessary. (Turn the span potentiometer clockwise to close the motor, counterclockwise to open the motor.) Verify the mid point of your stroke. T T Com + V+. or sequential operation at two or more motors (as shown in ig. 6), repeat the above steps for each motor, individually adjusting each for the desired response to the input signal. L L (HOT) T T COM I+ -0 ma CONTROLLER + SPAN ZERO T T COM I+ CCW CW CONTROL OUTPUT ma CURRENT (OR VOLTS DC) ig.. Q70A terminals and adjustments. 0 (0) 6 (8) (6) 8 () () 0 M7 CLOSED OPEN CLOSED OPEN CLOSED OPEN PROPORTIONS BETWEEN AND ma; ULLY CLOSED AT ma, ULLY OPENED AT ma. SEQUENTIAL OPERATION OR ADJUSTABLE ZERO AND SPAN MODELS PROPORTIONS BETWEEN 8 AND 6 ma; ULLY CLOSED AT 8 ma, ULLY OPENED AT 6 ma. PROPORTIONS BETWEEN AND 0 ma SIGNAL; ULLY CLOSED AT ma, ULLY OPENED AT 0 ma. UP TO 6 S CAN BE DRIVEN SEQUENTIALY OR IN UNISON ROM ONE CONTROLLER. ADJUST ZERO ADJUST AND SPAN ADJUST POTENTIOMETERS TO ACHIEVE DESIRED SEQUENCE. M89A ig. 6. Sequential operation of three motors with Q70A Interface Module. T T POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQURED. CONNECTING TO EITHER (+) OR (-) WILL DRIVE THE TO ULLY OPEN. DRIVE UP TO SIX S IN UNISON. EACH MUST HAVE SEPARATE TRANSORMER. I COMMON LINE VOLTAGE SUPPLY MUST BE USED, ADD ISOLATION TRANSORMER TO EACH M9XX. INTERNAL MODUTROL IV CONNECTION. COM I+ M06H ig. 7. Typical wiring diagram for Q70A Interface Module and M9XXX Modutrol IV Motor with -0 ma controller. L (HOT) L T T ig. 8. Typical wiring diagram for Q70A Interface Module and M9XXX Modutrol IV Motor with -0 Vdc controller. -0 Vdc CONTROLLER POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQURED. CONNECTING TO EITHER (+) OR (-) WILL DRIVE THE TO ULLY OPEN. INTERNAL MODUTROL IV CONNECTION. COM V+ + M

6 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES (+) and (-) denotes terminals on the controller Table. Q70/M9XX Checkout Procedure. Step Proper Motor Response Switch in Clockwise Position Switch in Counterclockwise Position. Open terminals (+), (-), Motor closes fully ccw Motor opens fully cw. Jumper to (-) Motor opens fully cw Motor closes fully ccw. Remove either T terminal Spring return motors return to normal spring position (fully ccw for mechanically normally closed motors, fully cw for mechanically normally open motors). Q70A Adjustments (ig. 9 and Table ) The Q70A provides control interface for W96 and W9 controllers. This module consists only of the terminal block and does not require any adjustments. See ig. 9 for terminals. After the motor stroke is adjusted (if necessary), simply plug the module onto the motor quick-connect terminals and secure to the motor. See ig. 0 for typical system wiring. To check proper motor operation: L (HOT) L ELECTRONIC MODULATING DAMPER S T T ELECTRONIC CENTRAL PROCESSOR OPTIONAL MINIMUM POSITION POTENTIOMETER. Provide power to the motor.. Jumper terminals and to drive motor open (clockwise as viewed from power end).. Jumper terminals and to drive motor closed. Connect field wiring to appropriate screw terminals. T T CHANGEOVER CONTROLLER T T T T POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQURED. SEE APPROPRIATE SYSTEM CONTROL INSTRUCTIONS OR CONNECTIONS TO CENTRAL PROCESSOR. (LABELED E ON W96 OR T ON W9). ig. 9. Q70A terminals. M7 IVE PERCENT CARBON RESISTOR. VALUE VARIES WITH NUMBER O S PARALLELED (000 OHMSÐ S, 80 OHMSÐ S. AUTHORITY O MINIMUM POSITION POTENTIOMETER I USED, INCREASES WITH NUMBER O S PARALLELLED ( OHMS ON Ð0 PERCENT STROKE, ON SÐ 00 PERCENT STROKE, ON SÐ0 PERCENT STROKE). USE AUXILIARY END O M98 TO REPLACE M9B; M7D S TO SPRING RETURM TO THE NORMALLY OPEN POSITION. M87C ig. 0. Typical wiring diagram for Q70A Interface Module and M9XX Modutrol IV Motor

7 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES Table. Q70/M9XX Checkout Procedure. Step. Disconnect leads from terminals,,,.. With motor powered jumper terminals and.. Remove either T terminal or disconnect power supply. Proper Motor Response for Normally Closed Motor Motor closes. (ully ccw as viewed from power end). Motor drives open (clockwise as viewed from powered end). Proper Motor Response for Normally Open Motor Motor opens. (ully cw as viewed from the power end) Motor drives closed (counterclockwise as viewed from the power end). Spring return motors return to normal spring position (fully ccw for mechanically normally closed motors, fully cw for mechanically normally open motors

8 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES Automation and Control Solutions Honeywell International Inc. 98 Douglas Drive North Golden Valley, MN By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Honeywell Limited-Honeywell Limitée Dynamic Drive Toronto, Ontario MV Z9 customer.honeywell.com U.S. Registered Trademark 0 Honeywell International Inc T.D. Rev. 0- Printed in U.S.A.

Series 71, 72, and 76 Modutrol IV Motors

Series 71, 72, and 76 Modutrol IV Motors Series 7, 7, and 76 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 7, 7 and 76 Modutrol IV Motors are spring return and nonspring return motors used to control dampers and valves. The

More information

T7079A,B Solid State Remote Temperature Controllers

T7079A,B Solid State Remote Temperature Controllers T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature

More information

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 1/99 Modutrol Motors Selection Guide This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 2-POSITION SPRING

More information

Series 90 Modutrol IV Motors

Series 90 Modutrol IV Motors Series 90 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 90 Modutrol IV Motors are spring return and non-spring return modulating proportional control motors. Use these motors with controllers

More information

R81CAA, R81DAA Type Digital Interface Plug-in Circuit Board Kit For Series M100 Motor Actuators

R81CAA, R81DAA Type Digital Interface Plug-in Circuit Board Kit For Series M100 Motor Actuators R81CAA, R81DAA Type Digital Interface Plug-in Circuit Board Kit For Series M100 Motor Actuators Installation Sheets Manual 121 Relays and Contactors Section R Technical Bulletin R81CAA Application R81

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Series 90 Modutrol IV Motors

Series 90 Modutrol IV Motors Series 90 Modutrol IV Motors FEATURES PRODUCT DATA APPLICATION The Series 90 Modutrol IV Motors are spring return and non-spring return modulating proportional control motors. Use these motors with controllers

More information

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting

More information

VOLTAGE REGULATOR INSTRUCTION MANUAL FOR SE250 SE400

VOLTAGE REGULATOR INSTRUCTION MANUAL FOR SE250 SE400 VOLTAGE REGULATOR INSTRUCTION MANUAL FOR SE250 SE400 INTRODUCTION The SE250 and SE400 voltage regulators are partially encapsulated electronic voltage regulators which control the output of a brushless

More information

Y7230A CO 2 Alarm System

Y7230A CO 2 Alarm System Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.

More information

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 6 PIN INTERFACE CONNECTOR HEIGHT CONTROL KNOB CAP 04 CAPACITIVE HEIGHT CONTROLLER DOWN IN POSITION UP TOUCH CABLE FAULT AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines

More information

Installation Guide TH3210D. Non-programmable Digital Thermostat

Installation Guide TH3210D. Non-programmable Digital Thermostat Installation Guide TH3210D Non-programmable Digital Thermostat Product Application This thermostat provides electronic control of 24 VAC heat pump systems with auxiliary heat (2 heat/1 cool). Power Type

More information

Installation Guide TH3110D. Non-programmable Digital Thermostat

Installation Guide TH3110D. Non-programmable Digital Thermostat Installation Guide TH3110D Non-programmable Digital Thermostat Product Application This thermostat provides electronic control of 24 VAC single-stage heating and cooling systems, or 750 mv heating systems.

More information

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE Service Information Calibration & Adjustments CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS Part Number DYN1-10752-000-0-12/24 DYN1-10752-001-0-12/24* DYN1-10753-000-0-12/24

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

Installation Guide TH4210D. Programmable Thermostat

Installation Guide TH4210D. Programmable Thermostat Installation Guide TH4210D Programmable Thermostat Product Application This thermostat provides electronic control of 24 VAC heat pump systems with auxiliary heat (2 heat/1 cool). Power Type Battery power

More information

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

Servo Info and Centering

Servo Info and Centering Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor

More information

Digi-Motor Installation Guide

Digi-Motor Installation Guide Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications

AE8-1328 R5 March 2011. Copeland Digital Compressor Controller AE8-1328 R5. Specifications AE8-1328 R5 March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the Copeland

More information

Installation Guide TH4110B. Programmable Thermostat

Installation Guide TH4110B. Programmable Thermostat Installation Guide TH4110B Programmable Thermostat Product Application This thermostat provides electronic control of 24 VAC single-stage heating and cooling systems, or 750 mv heating systems. System

More information

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual

Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position

More information

Generator Automatic Voltage Regulator Operation Manual

Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator 15 Amp 3 Phase Sensing AVR 1. INTRODUCTION Sensing Input Voltage Frequency Power Input Voltage Output Voltage

More information

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:

More information

UV100A Ultraviolet Air Treatment System

UV100A Ultraviolet Air Treatment System UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

Focus 3. Rugged and Robust. Conveyor Rugged. Focus 3. Focus Chassis. Overview

Focus 3. Rugged and Robust.  Conveyor Rugged. Focus 3. Focus Chassis. Overview www.emersonct.com Rugged and Robust Overview The is a single-phase analog drive for DC motors with power ranges from 1/4 to 5 HP. Years of proven engineering design matched with surface mount technology

More information

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators S, S Series Low-Torque Spring- Return Direct-Coupled Actuators S, S, S, S, S, S INSTALLATION AND OPERATING INSTRUCTIONS S, S Series Low-Torque Spring-Return Direct-Coupled Actuators (DCA) are used for

More information

SLATE. Analog I/O Module INSTALLATION INSTRUCTIONS R8001U3001

SLATE. Analog I/O Module INSTALLATION INSTRUCTIONS R8001U3001 SLATE Analog I/O Module R8001U3001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

Variable Air Volume (VAV) EC Motor Control

Variable Air Volume (VAV) EC Motor Control Variable Air Volume (VAV) EC Motor Control G3 PWM BARD The Enviro-Tec Generation 3 PWM (G3 PWM) board provides a pulse-width modulated (PWM) signal to the EC motor to control fan speed. The board is factory

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

V4295A,S; V8295A,S Solenoid Gas Valves

V4295A,S; V8295A,S Solenoid Gas Valves V4295A,S; V8295A,S Solenoid Gas Valves INSTALLATION INSTRUCTIONS FEATURES APPLICATION The electrically operated V4295A, S and V8295A, S Solenoid Gas Valves control the flow of natural and LP (liquefied

More information

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators FEATURES PRODUCT DATA Push-in clip, split nut, and adapter assembly for easy pilot burner installation. Q335 Spade or quick-connect

More information

Cross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors

Cross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors Cross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors 63-2691-01 Modutrol IV Motor Cross Reference FOR HONEYWELL AND COMPETITIVE MOTORS HOW TO USE THIS MANUAL This cross

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

Installation Instructions

Installation Instructions 0.1.2....6.7..9 1 0.1.2....6.7..9 1 Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its fail-safe position.

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

SX460. Generator Automatic Voltage Regulator Operation Manual

SX460. Generator Automatic Voltage Regulator Operation Manual SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.

More information

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 8 PIN INTERFACE CAP 04 CAPACITIVE HEIGHT CONTROLLER DOWN IN POSITION UP CABLE FAULT Description:

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

TR21, TR22, TR23, and TR24 Wall Modules

TR21, TR22, TR23, and TR24 Wall Modules TR21, TR22, TR23, and TR24 Wall Modules FEATURES INSTALLATI INSTRUCTIS The TR21, TR22, TR23, and TR24 family of wall modules include: Models with setpoint adjustment. Models with humidity output. Models

More information

F500 Whole House/ Light Commercial HEPA Filtration System

F500 Whole House/ Light Commercial HEPA Filtration System F500 Whole House/ Light Commercial HEPA Filtration System FEATURES PRODUCT DATA/OWNER S GUIDE APPLICATION The F500 Whole House/Light Commercial HEPA Air Cleaner connects to the return air duct of a forced

More information

Automatic Voltage Regulator User s Manual

Automatic Voltage Regulator User s Manual Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright

More information

Installation and Operating Manual

Installation and Operating Manual DC DRIVE BC138 BC139 DC CONTROL Installation and Operating Manual 7/2001 MN708 TABLE OF CONTENTS Section Page i. Simplified Operating Instructions.......................................... 1 ii. Safety

More information

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series Description: The Dual Solenoid Multifunction Valve

More information

Ametek, Inc. Rotron Technical Products Division. 627 Lake Street Kent, Ohio User's Guide. Number Revision E

Ametek, Inc. Rotron Technical Products Division. 627 Lake Street Kent, Ohio User's Guide. Number Revision E Ametek, Rotron Technical Products Division 627 Lake Street Kent, Ohio 44240 User's Guide 120 Volt, 800 Watt and 240 Volt, 1200 Watt Brushless Motor Drive Electronics 5.7" (145 mm) and 7.2" (183 mm) Windjammer

More information

PLC Line. USER S MANUAL Catalog No Rev. E

PLC Line. USER S MANUAL Catalog No Rev. E PLC Line USER S MANUAL Catalog No. 100125 Rev. E May 2015 Copyright 2015 Intelitek Inc. PLC Line User s Manual Catalog No. 100125 Rev. E May 2015 Every effort has been made to make this technical note

More information

Rack Mount Series Installation Guide

Rack Mount Series Installation Guide Rack Mount Series Installation Guide Models include: Maximal1RH Maximal1R - 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected

More information

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls TM TM INSTALLATION AND OPERATING INSTRUCTIONS VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls Model KBWM-120 rated 1/100-1/3 HP (90 Volts DC) @ 115 Volts AC, 50/60 Hz Model KBWM-240 rated

More information

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,

More information

MAXIGARD A1000 SPEED SWITCH. Introduction

MAXIGARD A1000 SPEED SWITCH. Introduction A102-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A1000 SPEED SWITCH Introduction The Maxigard A1000 speed switch is designed to monitor

More information

Solid-State Timer H3G

Solid-State Timer H3G Solid-State Timer Low-Cost, Plug-In Timer with Large Switching Capacity Up to 7-amp switching capacity Choose SPDT or DPDT contact form 12 time ranges Fits standard 8-pin sockets Ideal replacement for

More information

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual

KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions

More information

SDV1092-8 Music Mixer / Equaliser Installation guide and user manual

SDV1092-8 Music Mixer / Equaliser Installation guide and user manual EIGHT CHANNEL MIXER/EQUALISER SDV1092-8 Music Mixer / Equaliser Installation guide and user manual 1 CONTENTS CONTENTS...2 SAFETY NOTES...3 INTRODUCTION...4 USER CONTROLS...7 VOLUME CONTROL...7 MUSIC SOURCE

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

B3000 SERIES TACHOMETER ANALOG OR DIGITAL DISPLAY

B3000 SERIES TACHOMETER ANALOG OR DIGITAL DISPLAY B152-05, Page 1 952-361-3026 PROCESS CONTROL SYSTEMS, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 B3000 SERIES TACHOMETER ANALOG OR DIGITAL DISPLAY Introduction The

More information

IQ151 CONTROLLER DATA SHEET

IQ151 CONTROLLER DATA SHEET IQ151 CONTROLLER DATA SHEET The IQ151 is a controller in the Trend range with 64 inputs and 32 outputs. Full DDC (direct digital control) with PID control loops is provided. The output channels may be

More information

T775U Series 2000 Electronic Stand-Alone Controller

T775U Series 2000 Electronic Stand-Alone Controller T775U Series 2000 Electronic Stand-Alone Controller INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The T775 electronic stand-alone controllers are the next generation of universal controls capable of remote

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

MPL SERIES INSTRUCTION MANUAL MP SERIES

MPL SERIES INSTRUCTION MANUAL MP SERIES TM MP SERIES MPL SERIES INSTRUCTION MANUAL P O Box 865, Bozeman, MT 5977 Phone (406) 587-490 Fax (406) 587-49 email sales@wavelengthelectronics.com www.wavelengthelectronics.com TABLE OF CONTENTS Features...

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OM ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL PERFORMANCE 12V / 24V Model Torque Speed Motor Motor Speed 12V DC/ AC 24V DC/ AC No. (Nm) (90 0 ) Power 12 V 24 V Run Start Lock Run Start Lock OM-A

More information

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle s 4 502 ACVATIX Electromotoric rotary actuators for butterfly or slipper valves SAL.. with 90 rotary angle SAL31.. Operating voltage AC 230 V, 3-position control signal SAL61.. Operating voltage AC/DC

More information

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB TB6980/TB7980 1. Introduction The TB6980/TB7980 digital thermostats provide proportional plus integral individual space temperature control in zoned commercial HVAC systems such as hydronic and pressure

More information

Installation Guide - Alarm Module T941AM8

Installation Guide - Alarm Module T941AM8 Alarm Module T9AM Installation Guide - Alarm Module T9AM T9AM has physical inputs for connection to external alarm devices. Inputs are galvanically isolated, have transient protection, and can be programmed

More information

Analog Servo Drive 25A8

Analog Servo Drive 25A8 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

M68EVB908QL4 Development Board for Motorola MC68HC908QL4 M68EVB908QL4 Development Board for Motorola MC68HC908QL4! Axiom Manufacturing 2813 Industrial Lane Garland, TX 75041 Email: Sales@axman.com Web: http://www.axman.com! CONTENTS CAUTIONARY NOTES...3 TERMINOLOGY...3

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

VA-715x Electric Valve Actuator

VA-715x Electric Valve Actuator 14-986-7,Rev.GProduct/Technical Bulletin VA-7150 Issue Date March 2016 VA-715x Electric Valve Actuator The VA-715x Series synchronous motor-driven actuator provides incremental (three wire), incremental

More information

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal

More information

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...

More information

Generator Automatic Voltage Regulator

Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Suitable for Single or Three Phase Self Excited Bru shless Generator Compatible replacement for Mecc Alte SR-7 * Not a genuine Mecc Alte product.

More information

MDC151-024031 Series

MDC151-024031 Series MDC151-024031 Series 24V, 3A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

Router Set-up for Cable/Broadband/DSL Application CONFIGURATION INSTRUCTIONS FOR USE WITH WEBSTAT CONTROLLER

Router Set-up for Cable/Broadband/DSL Application CONFIGURATION INSTRUCTIONS FOR USE WITH WEBSTAT CONTROLLER Router Set-up for Cable/Broadband/DSL Application CONFIGURATION INSTRUCTIONS FOR USE WITH WEBSTAT CONTROLLER QUICK START GUIDE There are two steps that need to be taken to setup up a router to communicate

More information

Installation Guide TH5220D. Non-programmable Digital Thermostat

Installation Guide TH5220D. Non-programmable Digital Thermostat Installation Guide TH5220D Non-programmable Digital Thermostat Product Application This thermostat provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems, or 750

More information

Lab 3 - DC Circuits and Ohm s Law

Lab 3 - DC Circuits and Ohm s Law Lab 3 DC Circuits and Ohm s Law L3-1 Name Date Partners Lab 3 - DC Circuits and Ohm s Law OBJECTIES To learn to apply the concept of potential difference (voltage) to explain the action of a battery in

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

MODEL 2202IQ (1991-MSRP $549.00)

MODEL 2202IQ (1991-MSRP $549.00) F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Four/Five Axis TB6560 CNC Driver Users Manual

Four/Five Axis TB6560 CNC Driver Users Manual Four/Five Axis TB6560 CNC Driver Users Manual Revision 2.0. Oct. 16. 2009 1 Content 1. GENERAL INFORMATION... 3 1.1. Scope... 3 1.2. General Description... 3 1.3. Key Features... 3 2. Descriptions of 4/5-AXIS

More information