Q7130A, Q7230A, Q7330A Modutrol IV Interface Modules
|
|
- Winfred Osborne
- 7 years ago
- Views:
Transcription
1 Q70A, Q70A, Q70A Modutrol IV Interface Modules EATURES INSTALLATION INSTRUCTIONS Q70A APPLICATION Q70A Q70A The Q70, Q70, and Q70 Modutrol IV Interface Modules are used with Series 90 Modutrol IV Motors (M9XX) for conversion to electronic (Series 70) control. Mounts inside the wiring box of any Series 90 Modutrol IV Motor (M9XX models). Module protected from weather by the Modutrol IV NEMA wiring box. Mates to quick-connect terminals in motor wiring box and provides screw terminals for control wiring connections. eatures solid state circuitry with surface mount components. Plastic enclosure provides easy handling and protection for circuitry. Q70A provides selectable voltage range (-7, 6-9, or 0.-. Vdc). Adapts M9XX Modtrol IV Motor to function as M7XX model for M7H,J, M7D, M7G,P replacements. Includes reversing switch to allow replacement of electrically normally open or electrically normally closed motors. Q70A provides current or voltage control (-0 ma and -0 Vdc) with adjustable zero and span. Adapts the M9XX Modutrol IV Motor to function as M7XX model for M7S,T,Y or M7S,T,Y replacements. Includes reversing switch to allow replacement of electrically normally open or electrically normally closed motors. Q70A is an interface to W96 and W9 controls. Adapts the M9XX Modutrol IV Motor to function as M7XX model for M7D, M7A, M7A replacements. Put Bar Code Here 6--07
2 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES SPECIICATIONS IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed. Input Impedance: Q70A: >00k ohms. Q70A: voltage input >00k ohms; current input 67 ohms. Temperature Rating: -0 to +0 [-0 C to + 66 C]. Dimensions: See ig.. Models: Q70A Modutrol IV Interface Module: Used with M9XX Modutrol IV Motor to replace M7XX Motor applications. Module controls only one motor. See Table. Q70A Modutrol IV Interface Module: Used with M9XX Modutrol IV Motor to replace M7XX Motor applications. Module controls only one motor. See Table. Q70A Modutrol IV Interface Module: Used with M9XX Modutrol IV Motor to replace M7XX Motor applications. Module controls only one motor. See Table. -9/6 (9) -/ (96) Electrical Ratings: -/6 (78) M7 Input Voltage: Vac, 0/60 Hz. Power Consumption: VA. ig.. Q70,Q70,Q70 Modutrol IV Interface Module dimensions in in. (mm). a b Table. Interface Module unction/application Chart. And Replaces This Model Provides Interface or These Old Style Motors a When Used with Series 90 Models: Q70A Selectable voltage ranges: -7, 6-9, or 0. to. Vdc M7H M96D009 M7J M7D b M98D0 M7G M98A08 Q70A Adjustable zero and span, voltage or current M98D0 M7S M98D0 control (includes -0 ma and -0 Vdc). M7T M7Y M7S M98D00 M7T M7Y Q70A W96 or W9 control interface. M7D M96D009 M7A M98D0 M7A M98D00 Refer to customer.honeywell.com for cross-reference details. M7D07 and M7D0 do not apply. 6-07
3 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES INSTALLATION When Installing This Product. Read these instructions carefully. ailure to follow them could damage the product or cause a hazardous condition.. Check the ratings and description given in this specification to make sure the product is suitable for your application.. Installer must be a trained, experienced service technician.. After installation is complete, check out product operation as provided in these instructions.. Excessive force can damage potentiometer controls. Use a small screwdriver when adjusting all potentiometers located on the unit. CAUTION Disconnect power before installation to prevent electrical shock or equipment damage. IMPORTANT: or ease of adjustment, make all stroke and auxiliary switch adjustments before installing the interface module. After installation, access to the stroke adjust cams and auxiliary switches inside the motor is restricted. or complete details on performing these adjustments, refer to the specification sheet packed with the Modutrol Motor. Installing Terminal Block CAUTION When installing the terminal block on the motor quick connects, push the board straight down. Rocking or tilting of the board can damage the electrical connectors and result in an inoperative wiring module.. Disconnect power from the M9XX Modutrol IV Motor to prevent electrical shock or equipment damage.. Remove wiring box cover from the motor by removing four screws.. Disconnect all field wiring from the motor.. If motor has an internal transformer, make sure transformer is not powered and disconnect secondary wires from T and T terminals. Clip quick-connect terminations from transformer secondary (brown) wires. Trim /8 to / in. ( to 6 mm) of insulation from the ends of the wire. Tin wire ends with solder.. Plug terminal block onto quick-connect terminals inside wiring box. 6. Connect field wiring to screw terminals on terminal block. See ig.,, and 9 for terminal designations. Trim wire ends neatly and tin with solder. 7. Position circuit module and secure. SETTINGS AND ADJUSTMENTS Module Adjustments Q70A Adjustments (ig. ) The Q70A provides selectable range, two-wire voltage control (-7, 6-9 or 0.-. Vdc). It includes a clockwise/ counterclockwise (cw/ccw) switch for replacing electrically normally open or electrically normally closed motors. Please remove film from CW/CCW switch before use.. Set Mod IV motor pots both CW or both CCW for your application. Use the checkout procedure in Table to ensure proper motor function.. Select desired voltage range using the three-position switch reference chart for dip switch settings (see ig. ).. Select desired rotation. Select cw for electrically normally closed (motor drives clockwise, as viewed from power end, to open with an increase in control signal). Select ccw for electrically normally open (motor drives counterclockwise, as viewed from power end, to close with an increase in control signal) (default switch position is clockwise).. See ig. for typical system wiring.. Set controller to drive motor to fully open position and then to fully closed position to check for proper operation. Q M96 ig.. DIP switch reference. 6-07
4 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES T T C+ A L (HOT) L V TRANSORMER C T R T + MODULATING DC VOLTAGE SOURCE CCW CW ig.. Q70A terminals and adjustments. M7 POWER SUPPLY. ADD DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. OPTIONAL NORMALLY OPEN SWITCH. WITH CCW SELECTION, WILL RUN TO ULLY CLOSED; WITH CW SELECTION WILL RUN TO ULLY OPEN WHEN THIS SWITCH CLOSES (AS LONG AS POWER IS APPLIED TO T, T TERMINALS). OPTIONAL NORMALLY CLOSED SWITCHES. INE SILVER OR DRY CONTACTS REQUIRED. WITH CCW SELECTION, WILL RUN TO ULLY OPEN; WITH CW SELECTION, WILL RUN TO ULLY CLOSED WHEN SWITCH IN EITHER C OR R LEAD IS OPENED. M0C ig.. Typical system wiring for Q70A Interface Module and M9XX Modutrol Motor. Table. Q70A/M9XX Checkout Procedure. Step Proper Motor Response Switch in Clockwise Position Switch in Counterclockwise Position. Open terminal C or R. Motor runs closed (fully ccw). Motor runs open (fully cw).. Jumper terminals C and. Motor runs fully open (fully cw). Motor runs fully closed (fully ccw).. Remove either T terminal or disconnect power supply. Spring return motors return to normal spring position (fully ccw for mechanically normally closed motors; fully cw for mechanically normally open motors). Q70 Adjustments (ig. and Table ) The Q70A provides adjustable range (zero and span) for two-wire current or voltage control. Separate potentiometers are provided on the circuit module for adjusting the zero point and the span. It includes a cw/ccw switch for configuring the motor to rotate clockwise or counterclockwise with an increase in control signal.. Set Mod IV motor pots both CW or both CCW for your application. Use the checkout procedure in Table to ensure proper motor function.. Verify that the zero potentiometer is fully clockwise and that the span potentiometer is fully counterclockwise. (Do not exceed the stop point of the potentiometer.). Select desired rotation direction [cw (electrically normally closed) is the most common]. The following directions apply for the clockwise setting. or counterclockwise setting, reverse open and closed, and reverse clockwise and counterclockwise. Remove film on switch before use. (Default switch position is CW.). See ig. 7 and 8 for typical system wiring.. or current control, connect the current input signal to I+ (screw terminal ) and COM (screw terminal ). or voltage control, connect the voltage input signal to V+ (screw terminal ) and COM (screw terminal ). 6. Set the controller to output the signal required to drive the motor to the closed position. Wait for the motor to stop driving closed. 7. Turn the zero potentiometer slowly counterclockwise until the motor starts to open. 8. Turn the zero potentiometer slowly clockwise until the motor is fully closed. This is defined as the zero setting. 9. Set the controller to output the signal required to drive the motor to the fully open position. Wait for the motor to stop driving open. 0. Turn the span potentiometer slowly clockwise until the motor starts to drive closed. The difference between the fully open position signal and the fully closed position signal is defined as the operating span.. Recheck the fully closed position and readjust the zero potentiometer, if necessary. (Turn the zero potentiometer clockwise to close the motor and counterclockwise to open the motor.) 6-07
5 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES. Recheck the fully open position and readjust the span potentiometer, if necessary. (Turn the span potentiometer clockwise to close the motor, counterclockwise to open the motor.) Verify the mid point of your stroke. T T Com + V+. or sequential operation at two or more motors (as shown in ig. 6), repeat the above steps for each motor, individually adjusting each for the desired response to the input signal. L L (HOT) T T COM I+ -0 ma CONTROLLER + SPAN ZERO T T COM I+ CCW CW CONTROL OUTPUT ma CURRENT (OR VOLTS DC) ig.. Q70A terminals and adjustments. 0 (0) 6 (8) (6) 8 () () 0 M7 CLOSED OPEN CLOSED OPEN CLOSED OPEN PROPORTIONS BETWEEN AND ma; ULLY CLOSED AT ma, ULLY OPENED AT ma. SEQUENTIAL OPERATION OR ADJUSTABLE ZERO AND SPAN MODELS PROPORTIONS BETWEEN 8 AND 6 ma; ULLY CLOSED AT 8 ma, ULLY OPENED AT 6 ma. PROPORTIONS BETWEEN AND 0 ma SIGNAL; ULLY CLOSED AT ma, ULLY OPENED AT 0 ma. UP TO 6 S CAN BE DRIVEN SEQUENTIALY OR IN UNISON ROM ONE CONTROLLER. ADJUST ZERO ADJUST AND SPAN ADJUST POTENTIOMETERS TO ACHIEVE DESIRED SEQUENCE. M89A ig. 6. Sequential operation of three motors with Q70A Interface Module. T T POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQURED. CONNECTING TO EITHER (+) OR (-) WILL DRIVE THE TO ULLY OPEN. DRIVE UP TO SIX S IN UNISON. EACH MUST HAVE SEPARATE TRANSORMER. I COMMON LINE VOLTAGE SUPPLY MUST BE USED, ADD ISOLATION TRANSORMER TO EACH M9XX. INTERNAL MODUTROL IV CONNECTION. COM I+ M06H ig. 7. Typical wiring diagram for Q70A Interface Module and M9XXX Modutrol IV Motor with -0 ma controller. L (HOT) L T T ig. 8. Typical wiring diagram for Q70A Interface Module and M9XXX Modutrol IV Motor with -0 Vdc controller. -0 Vdc CONTROLLER POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQURED. CONNECTING TO EITHER (+) OR (-) WILL DRIVE THE TO ULLY OPEN. INTERNAL MODUTROL IV CONNECTION. COM V+ + M
6 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES (+) and (-) denotes terminals on the controller Table. Q70/M9XX Checkout Procedure. Step Proper Motor Response Switch in Clockwise Position Switch in Counterclockwise Position. Open terminals (+), (-), Motor closes fully ccw Motor opens fully cw. Jumper to (-) Motor opens fully cw Motor closes fully ccw. Remove either T terminal Spring return motors return to normal spring position (fully ccw for mechanically normally closed motors, fully cw for mechanically normally open motors). Q70A Adjustments (ig. 9 and Table ) The Q70A provides control interface for W96 and W9 controllers. This module consists only of the terminal block and does not require any adjustments. See ig. 9 for terminals. After the motor stroke is adjusted (if necessary), simply plug the module onto the motor quick-connect terminals and secure to the motor. See ig. 0 for typical system wiring. To check proper motor operation: L (HOT) L ELECTRONIC MODULATING DAMPER S T T ELECTRONIC CENTRAL PROCESSOR OPTIONAL MINIMUM POSITION POTENTIOMETER. Provide power to the motor.. Jumper terminals and to drive motor open (clockwise as viewed from power end).. Jumper terminals and to drive motor closed. Connect field wiring to appropriate screw terminals. T T CHANGEOVER CONTROLLER T T T T POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQURED. SEE APPROPRIATE SYSTEM CONTROL INSTRUCTIONS OR CONNECTIONS TO CENTRAL PROCESSOR. (LABELED E ON W96 OR T ON W9). ig. 9. Q70A terminals. M7 IVE PERCENT CARBON RESISTOR. VALUE VARIES WITH NUMBER O S PARALLELED (000 OHMSÐ S, 80 OHMSÐ S. AUTHORITY O MINIMUM POSITION POTENTIOMETER I USED, INCREASES WITH NUMBER O S PARALLELLED ( OHMS ON Ð0 PERCENT STROKE, ON SÐ 00 PERCENT STROKE, ON SÐ0 PERCENT STROKE). USE AUXILIARY END O M98 TO REPLACE M9B; M7D S TO SPRING RETURM TO THE NORMALLY OPEN POSITION. M87C ig. 0. Typical wiring diagram for Q70A Interface Module and M9XX Modutrol IV Motor
7 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES Table. Q70/M9XX Checkout Procedure. Step. Disconnect leads from terminals,,,.. With motor powered jumper terminals and.. Remove either T terminal or disconnect power supply. Proper Motor Response for Normally Closed Motor Motor closes. (ully ccw as viewed from power end). Motor drives open (clockwise as viewed from powered end). Proper Motor Response for Normally Open Motor Motor opens. (ully cw as viewed from the power end) Motor drives closed (counterclockwise as viewed from the power end). Spring return motors return to normal spring position (fully ccw for mechanically normally closed motors, fully cw for mechanically normally open motors
8 Q70A, Q70A, Q70A MODUTROL IV INTERACE MODULES Automation and Control Solutions Honeywell International Inc. 98 Douglas Drive North Golden Valley, MN By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Honeywell Limited-Honeywell Limitée Dynamic Drive Toronto, Ontario MV Z9 customer.honeywell.com U.S. Registered Trademark 0 Honeywell International Inc T.D. Rev. 0- Printed in U.S.A.
Series 71, 72, and 76 Modutrol IV Motors
Series 7, 7, and 76 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 7, 7 and 76 Modutrol IV Motors are spring return and nonspring return motors used to control dampers and valves. The
More informationT7079A,B Solid State Remote Temperature Controllers
T7079A,B Solid State Remote Temperature Controllers FEATURES PRODUCT DATA Switch selection of heat or cool mode. Temperature sensing up to 400 feet. Does not require field calibration. 0K NTC temperature
More informationSeries 90 Modutrol IV Motors
Series 90 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 90 Modutrol IV Motors are spring return and non-spring return modulating proportional control motors. Use these motors with controllers
More informationThis chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.
1/99 Modutrol Motors Selection Guide This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 2-POSITION SPRING
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationSolid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C
Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting
More informationY7230A CO 2 Alarm System
Y7230A CO 2 Alarm System FOR CO 2 GAS DETECTION PRODUCT DATA FEATURES APPLICATION Y7230A CO 2 alarm system is used to detect gas leaking from CO 2 beverage dispensing systems and posts an alarm to occupants
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationDMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual
DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.
More informationService Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE
Service Information Calibration & Adjustments CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS Part Number DYN1-10752-000-0-12/24 DYN1-10752-001-0-12/24* DYN1-10753-000-0-12/24
More informationOEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
More informationA1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
More informationServo Info and Centering
Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationDigi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
More informationTelefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
More informationInstallation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types
Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:
More informationUV100A Ultraviolet Air Treatment System
UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism
More informationOrdering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V
Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input
More informationS03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators
S, S Series Low-Torque Spring- Return Direct-Coupled Actuators S, S, S, S, S, S INSTALLATION AND OPERATING INSTRUCTIONS S, S Series Low-Torque Spring-Return Direct-Coupled Actuators (DCA) are used for
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More informationQ309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators
Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators FEATURES PRODUCT DATA Push-in clip, split nut, and adapter assembly for easy pilot burner installation. Q335 Spade or quick-connect
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationTECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
More informationInstallation Instructions
0.1.2....6.7..9 1 0.1.2....6.7..9 1 Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its fail-safe position.
More informationSingle Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More informationSX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationCross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors
Cross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors 63-2691-01 Modutrol IV Motor Cross Reference FOR HONEYWELL AND COMPETITIVE MOTORS HOW TO USE THIS MANUAL This cross
More informationInstallation and Operating Manual
DC DRIVE BC138 BC139 DC CONTROL Installation and Operating Manual 7/2001 MN708 TABLE OF CONTENTS Section Page i. Simplified Operating Instructions.......................................... 1 ii. Safety
More informationAutomatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
More informationVARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls
TM TM INSTALLATION AND OPERATING INSTRUCTIONS VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls Model KBWM-120 rated 1/100-1/3 HP (90 Volts DC) @ 115 Volts AC, 50/60 Hz Model KBWM-240 rated
More informationKBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual
KBIC Solid State SCR DC Motor Speed Controls See table 2 page 4 for KBIC models covered by this manual Patented Ultra Fast CL Circuit Prevents Demagnetization in PM Motors Installation and Operating Instructions
More informationTAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
More informationN20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL
N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,
More informationImpulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations
Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations Addendum to: IMPULSE G+ Series 3 Manual (140-10258) IMPULSE VG+ Series 3 Manual (140-10257) This addendum should be used when a 24VDC
More informationTECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series
TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series Description: The Dual Solenoid Multifunction Valve
More informationTR21, TR22, TR23, and TR24 Wall Modules
TR21, TR22, TR23, and TR24 Wall Modules FEATURES INSTALLATI INSTRUCTIS The TR21, TR22, TR23, and TR24 family of wall modules include: Models with setpoint adjustment. Models with humidity output. Models
More informationTechnote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationM68EVB908QL4 Development Board for Motorola MC68HC908QL4
M68EVB908QL4 Development Board for Motorola MC68HC908QL4! Axiom Manufacturing 2813 Industrial Lane Garland, TX 75041 Email: Sales@axman.com Web: http://www.axman.com! CONTENTS CAUTIONARY NOTES...3 TERMINOLOGY...3
More informationM9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,
More informationT775U Series 2000 Electronic Stand-Alone Controller
T775U Series 2000 Electronic Stand-Alone Controller INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The T775 electronic stand-alone controllers are the next generation of universal controls capable of remote
More informationPART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
More informationSmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings
Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationMDC151-024031 Series
MDC151-024031 Series 24V, 3A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)
More information1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES
POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal
More informationPS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS
More informationINSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
More informationModel SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
More informationMODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
More informationAnalog Servo Drive 25A8
Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit
More informationUSER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
More informationXE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to
More informationPTU Series Ultrahigh-Purity Pressure Transducers
PTU Series UltrahighPurity Pressure Transducers User s Manual The Swagelok PTU series pressure transducer provides electronic monitoring of system pressure for ultrahighpurity applications. The PTU series
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More informationLab 3 - DC Circuits and Ohm s Law
Lab 3 DC Circuits and Ohm s Law L3-1 Name Date Partners Lab 3 - DC Circuits and Ohm s Law OBJECTIES To learn to apply the concept of potential difference (voltage) to explain the action of a battery in
More information!Operation:!1. Connect an external power source to J1 (+ and - IN terminals). The
The CB500 Electronic Circuit Breaker is an resettable circuit breaker (fuse) that disconnects power when the trip setting is exceeded. There are 4 trip settings that can easily be changed and set during
More information200W DISCRETE POWER AMPLIFIER K8060
H8060IP-1 200W DISCRETE POWER AMPLIFIER K8060 Ideal for active speaker system or subwoofer, guitar amp, home theatre systems, instrument amp, etc. Features & Specifications Specifications: Excellent value
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationSolid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
More informationSYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
More informationTotal solder points: 167 Difficulty level: beginner 1 2 3 4 5 advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL
Total solder points: 167 Difficulty level: beginner 1 2 3 4 5 advanced DMX CONTROLLED RELAY K8072 Control a relay by means of the wellknown DMX512 protocol. ILLUSTRATED ASSEMBLY MANUAL H8072IP-1 Features
More information1000 Series. Electronic Digital Actuators. Table of Contents
Instruction Manual IM-0657 1000 Series Electronic Digital Actuators Table of Contents General Information... 2-3 Product Specifications... 4 Physical Installation... 5 MV-1000 Component Indentification...
More informationEXPERIMENT 7 OHM S LAW, RESISTORS IN SERIES AND PARALLEL
260 7- I. THEOY EXPEIMENT 7 OHM S LAW, ESISTOS IN SEIES AND PAALLEL The purposes of this experiment are to test Ohm's Law, to study resistors in series and parallel, and to learn the correct use of ammeters
More informationCENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit
Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin
More informationIO-RM3 3-Stage Relay Module
Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED
More informationT775A/B/M Series 2000 Electronic Stand-Alone Controllers
T775A//M Series 2000 Electronic Stand-Alone Controllers INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The T775 electronic stand-alone controllers are the next generation of commercial and agricultural
More informationIPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
More informationInstallation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
More informationDORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More informationTotal solder points: 57 Difficulty level: beginner 1 2 3 4 5 advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1
Total solder points: 57 Difficulty level: beginner 1 2 3 4 5 advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 A power supply for all our kits, based on a stabilised DC voltage of 30V. ILLUSTRATED ASSEMBLY MANUAL
More informationLoop Calibration and Maintenance
Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains
More informationProtect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB
Protect IT MNS Motor Management INSUM MPU - Multi Purpose Unit - - ABB INSUM Multi Purpose Unit Revision 1.6 2 NOTICE The information in this document is subject to change without notice and should not
More informationT6570, T8570 Series Digital Fan-Coil Thermostats
T6570, T8570 Series Digital Fan-Coil Thermostats PRODUCT DATA APPLICATION T6570 Series Digital Fan-Coil thermostats provide line voltage on/off control for fans, valves, compressors or auxiliary electric
More informationFour/Five Axis TB6560 CNC Driver Users Manual
Four/Five Axis TB6560 CNC Driver Users Manual Revision 2.0. Oct. 16. 2009 1 Content 1. GENERAL INFORMATION... 3 1.1. Scope... 3 1.2. General Description... 3 1.3. Key Features... 3 2. Descriptions of 4/5-AXIS
More informationAddendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
More informationAMX300 DirectConnect Mixing Valve Kits
AMX300 DirectConnect Mixing Valve Kits INSTALLATION INSTRUCTIONS Tools needed (not supplied) 1. Wrench 2. Pliers Safety Definitions These safety terms identify information you must read. CAUTION Indicates
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationCONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13
CONTENTS PAGE Chapter 1 General Information 1 Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13 Chapter 3 Alarm/Excitation Options 15 Wiring 17 Chapter
More information1 POLE - 5A SLIM POWER RELAY
POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw
More informationInstallation Guide. Programmable Thermostat TH6220D
Installation Guide Programmable Thermostat TH6220D Product Application This thermostat provides electronic control of 24 VAC single-stage and multi-stage heating and cooling systems, or 750 mv heating
More informationINSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
More informationSpeed Control Relays SX2
SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................
More informationPRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
More informationInstruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E 300-3.5E 50-20E 600-1.7E
DCS-E SERIES POWER SUPPLIES Instruction Manual This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E 300-3.5E 50-20E 600-1.7E SORENSEN Division of Elgar 9250 Brown Deer Road San Diego,
More informationFan Coil EC Motor Control
Fan Coil EC Motor Control G3 PWM BARD The Enviro-Tec Generation 3 PWM (G3 PWM) board provides a pulse-width modulated (PWM) signal to the EC motor to control fan speed. The board is factory programmed
More informationSYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationOperating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
More information