SECTION 12. AMERICAN Historical Data
|
|
- August Hood
- 7 years ago
- Views:
Transcription
1 SECION 12 MERICN Historical Data
2 MERICN Historical Data Obsolete Piping Materials Cast iron pipe will often last for centuries. One evidence of this is the world s oldest known cast iron water mains which were installed to supply water to the town and parks of Versailles, France. his pipe provided continuous service for more than 00 years. However, changing requirements and improved manufacturing techniques have resulted in some piping materials becoming obsolete. lthough no longer manufactured, many piping materials continue in service, such as cast iron pipe with caulked bell and spigot joints which was one of the earliest types of joints used for underground service. Over the years MERICN furnished millions of feet of gray cast iron pipe in sizes 2" through 48"; however, ductile iron has replaced gray iron in all of the pipe and fittings now being manufactured. In ductile iron, like in gray cast iron, MERICN has continued to make improvements in joints and configurations, eliminating some joints in the process. his section is included to furnish limited information pertaining to some of these obsolete materials. Contact MERI- CN for additional information if needed. Note: When connecting to or repairing existing pipelines, it is good practice to carefully examine/measure the items involved prior to procuring materials and prior to commencing labor- and equipmentintensive operations. his would require at least minimal exposure of existing buried pipelines for identification and measurement. Likewise, all OSH and other safety and governmental regulations should be complied with in such operations. MERICN HISORICL D OBSOLEE PIPING MERILS Cast Iron Pipe being replaced by a larger main is taken up after years of service for installation in another location for continued service. 12-1
3 MERICN HISORICL D OBSOLEE PIPING MERILS able No Wall hicknesses and Outside Diameters of Pit Cast Gray Iron Pipe Class 100 Ft. Head Wall hicknesses in Inches Class B 200 Ft. Head Class C 00 Ft. Head WW Standard Class D 400 Ft. Head Class 100 Ft. Head Outside Diameters in Inches Class B 200 Ft. Head Class C 00 Ft. Head Class D 400 Ft. Head * * In the time frame from the mid-1960s-1988, MERICN also produced centrifugally cast Fastite and various push-on restrained-joint ductile iron pipes with a nominal barrel O.D. (see ables 12-1,14). his specific O.D. 54 ductile iron pipe is no longer produced, and modern 54 pipe has a nominal O.D. MERICN Mono-Cast Gray Iron Pipe Standard Laying Conditions - Flat Bottom rench Untamped Backfill C - Pipe Laid on Blocks Untamped Backfill B - Flat Bottom rench amped Backfill D - Pipe Laid on Blocks amped Backfill Fig In the 1970 Revision of NSI 21.6 and 21.8, laying conditions C and D were deleted and laying condition F was added. See below F - Pipe bedded F in sand Pipe bedded in sand or gravel, or gravel, tamped backfill Fig. 12-2
4 MERICN Mono-Cast Bell and Spigot Gray Iron Pipe Centrifugally Cast in Sand-Lined Molds NSI 21.8 (WW C108) Standard able No Pattern B Dimensions in Inches D E F.96 BCD BCD BCD B CD B CD B CD B CD B CD B CD B CD B CD B B B B MERICN Mono-Cast Bell and Spigot Gray Iron Pipe was also manufactured in accordance with Federal Specification WW-P-421 in sizes 4" through 24" Class 150 and Class 250. he standard outside diameter was CD pattern for 14" through 24" pipe. lternate B pattern pipe in these sizes and B pattern pipe in 0" through 48" sizes were also produced. Pressure class thicknesses per NSI 21.8 (WW C108) were the same as for those shown for Mechanical Joint Pipe in able Nos and MERICN HISORICL D OBSOLEE PIPING MERILS able No. 12- Weight of Lead and Jute Per Joint WW Lead lb. Jute lb. Lead lb Jute lb. Lead lb. Jute lb.
5 MERICN Gray Iron Fastite Joint Pipe NSI/WW C111/21.11 Standard Dimensions MERICN HISORICL D OBSOLEE PIPING MERILS able No ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" For trim pipe allowance see WW C106. able No Laying ft.- Outside Diameter Dimensions in Inches D Depth of Socket F Bell O.D. Maximum MERICN Gray Iron Mechanical Joint Pipe NSI/WW C111/21.11 Standard Dimensions Dimensions in Inches Laying ft.- B J K 1 K 2 L M No. Per Joint G Bell I.D. Bolts 20' - 1" X ' - 1" X ' - 1" X ' - 1" X ' - 1" X ' - 1" X For trim pipe allowance see WW C
6 MERICN Gray Iron Pipe NSI/WW C106/21.6 Standard hickness Classes able No SNDRD CLSSES hickness in Inches Bold face figures indicate minimum Class thicknesses for 18/40 iron strength in accordance with WW C106. hicknesses shown for Classes 20 and 21 were regularly furnished by MERICN in higher (21/45) iron strength, designed by the standard WW C101 method. Calculated thicknesses, based on design conditions, were adjusted to the nearest Class thickness, or to the minimum Class thickness if below specified minimum thickness. MERICN HISORICL D OBSOLEE PIPING MERILS 12-5
7 MERICN HISORICL D OBSOLEE PIPING MERILS MERICN Gray Iron Fastite Joint and Mechanical Joint Pipe NSI/WW C106/21.6 WORKING PRESSURES Standard hicknesses and Weights "-12" s hese Classes of pipe were for water or other liquids for pipe under 5 feet of cover, laying condition B (see Fig.12-1) and for iron strengths indicated. able No Wall hickness hickness Class Per Foot Plain End 18/40 Iron 21/45 Iron Per Foot Incl.Bell Weight in Pounds Per 20' Per Foot Incl.Bell Per 20' Wall hickness hickness Class Per Foot Plain End Per Foot Incl.Bell Weight in Pounds FSIE JOIN MECHNICL JOIN FSIE JOIN MECHNICL JOIN Per 20' Per Foot Incl.Bell Per 20' 50 psi Working Pressure psi Working Pressure psi Working Pressure he 18/40 iron strength was per WW C106. he design details and standard thicknesses for pipe with 21/45 iron strength were covered in WW C101. he minimum thickness gray cast iron normally furnished in 4" size was.5" wall thickness (Class 22), and in 6" was.5" wall thickness (Class 21). 12-6
8 MERICN Gray Iron Fastite Joint and Mechanical Joint Pipe NSI/WW C106/21.6 WORKING PRESSURES Standard hicknesses and Weights "-12" s hese Classes of pipe were for water or other liquids for pipe under 5 feet of cover, laying condition B (see Fig.12-1) and for iron strengths indicated. able No Continued 18/40 Iron 21/45 Iron Wall hickness hickness Class Per Foot Plain End Per Foot Incl.Bell Weight in Pounds Per 20' Per Foot Incl.Bell Per 20' Wall hickness hickness Class Per Foot Plain End Per Foot Incl.Bell Weight in Pounds FSIE JOIN MECHNICL JOIN FSIE JOIN MECHNICL JOIN Per 20' Per Foot Incl.Bell Per 20' 200 psi Working Pressure psi Working Pressure he 18/40 iron strength was per WW C106. he design details and standard thicknesses for pipe with 21/45 iron strength were covered in WW C101. he minimum thickness gray cast iron normally furnished in 4" size was.5" wall thickness (Class 22), and in 6" was.5" wall thickness (Class 21). MERICN HISORICL D OBSOLEE PIPING MERILS 12-7
9 MERICN HISORICL D OBSOLEE PIPING MERILS MERICN Mono-Cast Mechanical Joint Gray Iron Pipe Centrifugally Cast in Sand-Lined Molds s NSI 21.8 (WW C108) Standard hese Classes of pipe were for water service and other liquids under 5 feet of cover, laying condition B (flat bottom trench with tamped backfill), and for iron strengths indicated. able No Outside Diameter hickness 18/40 IRON Per Foot Plain End Weight in Pounds Per Foot incl. Bell Per 16-Foot hickness 21/45 IRON Per Foot Plain End Weight in Pounds Per Foot incl. Bell Per 16-Foot 100 PSI Working Pressure CLSS Feet Head PSI Working Pressure CLSS Feet Head PSI Working Pressure CLSS Feet Head Iron of 18/40 strength was in accordance with NSI Iron of 21/45 strength was MERICN standard with thicknesses designed by the standard NSI method. MERICN furnished 14" through 24" Gray Iron Pipe in nominal 20-foot lengths for several years prior to discontinuing manufacture of Gray Iron Pipe in these sizes. MERICN currently manufactures Mechanical Joint ductile iron pipe in sizes 4" through 24". See Section. 12-8
10 MERICN Fastite Joint Gray Iron Pipe Centrifugally Cast in Sand-Lined Molds 14"-48" s NSI 21.8 (WW C108) Standard Federal Specification WW-P-421c able No Nominal Laying ft. O.D. D Socket Depth F Bell O.D. Max. Wall hickness Class /40 Iron Class /45 Iron Per Foot Plain End Weight in Pounds Per Foot Incl. Bell Per Wall hickness Per Foot Plain End Weight in Pounds Per Foot Incl. Bell Per Class /40 Iron Class /45 Iron MERICN currently manufactures Fastite ductile iron pipe in sizes 4" through 64". See Section. MERICN HISORICL D OBSOLEE PIPING MERILS 12-9
11 MERICN HISORICL D OBSOLEE PIPING MERILS MERICN Mechanical Locked Joint Centrifugally Cast Gray Iron Pipe MERICN Standard able No Dimensions in Inches X D K J M L Y No. Per Joint Bolts Safe End Pull in ons Pipe with MERICN Mechanical Locked Joints were furnished in a standard thickness class for a limited pressure rating varying with pipe size. For currently available restrained joints see Section
12 MERICN Flanged Gray Iron Pipe NSI (WW C115) Standard able No Pressure Rating psi hickness Class Wall hickness Pipe O.D. Standard * ft.- Per Foot Plain End Weight in Pounds NSI Flg** NSI 250 B16.1 Flg One Flange Std. Lgth. Pipe With 2 Flgs One Flange Std. Lgth. Pipe With 2 Flgs ' - 6" ' - 6" ' - 6" ' - 6" ' - 6" ' - 6" ' - 6" ' - 6" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" *olerance on length was + 1/16" for 2" through 10" sizes and + 1/8" for 12" and larger. **Standard drilling was for bolt holes to straddle centerline. Special drilling was furnished on request of purchaser. Flanges were not back faced unless specified. Pressure rating designated in table above was maximum water working pressure. MERICN HISORICL D OBSOLEE PIPING MERILS 12-11
13 MERICN brasion-resistant Pipe BHN 285 Minimum MERICN HISORICL D OBSOLEE PIPING MERILS able No O.D. Minimum hickness Maximum MJ & PE ft. Nominal Laying * PE & PE ft ' 19' - 6" ' 19' - 6" ' 19' - 6" ' 19' - 6" ' 19' - 6" ' 19' - 6" *Laying lengths were nominal and were subject to trim variations. Special O.D. pipe were available in some sizes. Standard WW C151 thickness classes as well as special thicknesses between the minimum and maximum specified above, were furnished. Lower or higher hardness grades were furnished. he higher grades were limited to plain end joints. For field cuts of abrasive-resistant pipe, abrasive cut-off wheels are recommended. able No MERICN Ductile Iron Lok-Set Joint Pipe Standard Dimensions Dimensions in Inches D F Set Screws* x x x x x x *Stainless Steel, ype 416. Minimum Class Ductile Iron Pipe for Lok-Set Joint 24" and 0" sizes was Class 51; for 6" - 54" sizes was Class 50. Nominal laying length which was subject to trim allowance was 20'. If exact lengths were required figure 19'-11" for 24" and 18' for 0" - 54". See Section for weights. Either Lok-Set Joint fittings or Lok-Fast Joint fittings were normally furnished for installation with Lok-Set Joint Pipe. pipe with combination of Lok-Set bell and Lok-Fast gland end facilitated the use of Lok-Fast fittings. 100 psi No. Set Screws Required for Internal Pressure 150 psi 200 psi 12-12
14 MERICN Ductile Iron Lok-Fast Joint Pipe Standard Dimensions able No Outside Diameter Nominal Laying ft.- B Socket Depth C Plain End to Gland J Bolt Circle K O.D.Gland and Flange hickness of Flange and Gland Center-to-socket dimensions for Lok-Fast fittings were normally the same as those for Mechanical Joint fittings. Socket depths of 14"-6" Lok-Fast fittings differed from those shown above. he dimensions for 42"- 54" Lok-Fast Pipe were, where applicable, the same for Lok-Fast fittings. Lok-Fast joints were made in the various configurations shown in various combination of diameters. Dimensions in this table relate to a certain combination of diameters and configurations and may not apply to other combinations. L M MERICN HISORICL D OBSOLEE PIPING MERILS 12-1
15 MERICN Ductile Iron hreaded Joint Pipe with Ductile Couplings MERICN HISORICL D OBSOLEE PIPING MERILS MERICN Ductile Iron hreaded Joint Pipe offered several advantages over other pipe materials, namely, long life, uniformity of product, high physical strength properties, and easy threading. able No Wall hickness Pipe Weight in Pounds Per Foot Per 19'-6" *Ribs were furnished on couplings only when specified. Special threading and long couplings could be furnished as desired. abulated wall thicknesses are special Class 5; heavier wall thicknesses could be furnished. Maximum length was 19' - 6". Design was for 250 psi water working pressure. D dimension on coupling had normal tolerance of ±0.12". hreaded Joint Pipe was furnished to the applicable requirements of NSI/WW C151/21.51 with standard ductile iron outside diameters. hreads were taper pipe threads in accordance with NSI B2.1 adapted to standard ductile iron pipe outside diameters, as shown above. his pipe could be furnished with linings and coatings as described in Section 11. C Coupling -58 Dimensions in Inches D D 1 Over- Ribs* Weight lb 12-14
16 MERICN Molox Ball Joint Pipe echnical Data M L pprox. /8" to 1/2" MERICN Stainless Steel ee-head Bolts able No N J Dimensions in inches K N J M L Contact MERICN for thickness dimensions. able No Laying /Overall B Laying Socket and Ball G.I. D.I ' - 0" ' - 2" ' - 0" ' - 2" ' - 0" ' - 2" ' " 20' - 2" ' " 20' - 2" ' " 15' - 10" ' - 9" ' " ' - 9" ' " ' - 8" ' " ' - 8" ' " ' " 15' - 7" ' " 15' - 7" ' - 6" ' - 6" ' - 6" 1 2 K No. Per Joint Bolts o obtain overall lengths of Molox Ball Joint Pipe when used in combination with other conditions, the following formulas were applicable: Molox Socket & Molox Ball..+B+L.L.* Molox Socket & Flange...+L.L.* Molox Socket & Plain End...+L.L.* Molox Ball & Flange...B+L.L.* Molox Ball & Plain End...B+L.L.* Molox Ball & Molox Ball...2B+L.L.* *Each "L.L." listed above refers to the laying length of the pipe with the particular combination of joints specified. he manufacture of 4" through 6" Molox Pipe was discontinued in 1975 and 42"-54" was discontinued in Prior to 1975 some 4" through 12" Molox Pipe was furnished of ductile iron with threaded-on bells; dimensions in able No applied. See Section 10 for 4"-54" Flex-Lok Pipe. pprox. Joint Deflection MERICN HISORICL D OBSOLEE PIPING MERILS
17 MERICN Molox Ball Joint Bends MERICN HISORICL D OBSOLEE PIPING MERILS When deflection in excess of that allowed for one joint was required, the necessary deflection would often be made in two or more successive joints. If the installation conditions did not allow this, increased deflections would be obtained by the use of MERICN Molox Ball Joint Bends, as shown above. hese bends were installed at any joint in the Molox Ball Joint pipeline. Bends were usually furnished with and 45 curvature, but other degrees of curvature were furnished when required. In the event MERICN Molox Ball Joint Bends were not adaptable to the particular piping installation, the use of MERICN Ball Joint Double Hubs to provide additional deflection was recommended. able No MERICN Molox Ball Joint Double Hubs Dimensions in inches L M N K J Weight lb Maximum Deflection Provided he angle of deflection provided by each end of the Molox Ball Joint Bend or Double Hub was the same as that indicated in able No for the corresponding size of MERICN Molox Ball Joint Pipe
18 MERICN Monoloy Centrifugally Cast Gray Iron Pipe Manufactured to Steel Pipe Outside Diameters MERICN Standard able No Pipe O.D. Pipe I.D. Wall hickness Standard ft.- Per Foot Plain End Weight in Pounds Per Per Plain End Flange -902 Per Coupling ' - 6" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" ' - 0" MERICN Monoloy Mechanical Joint Pipe (-905) was also available. MERICN Monoloy Pipe was discontinued in hreaded Joint Ductile Iron Pipe, 4"-24", is still available with ductile iron pipe outside diameters. See Section 2. MERICN HISORICL D OBSOLEE PIPING MERILS 12-17
19 MERICN 2" and 2 1 4" Centrifugally Cast Gray Iron Pipe NSI Standard.25".25" MERICN HISORICL D OBSOLEE PIPING MERILS " " able No ype Joint Plain End Pipe Mechanical Joint Pipe Max. Laying ft.- Bell or Flange.25" /4" /4" 2" Pipe Weight in Pounds Per Foot Plain End.8" " Flange and Flange Pipe Per Foot Incl. Bell Max. Laying -70 2" *With two flanges. he manufacture of 2" and 2 1 4" Pipe was discontinued in On Flange and Flange Pipe flanges were threaded on one or both ends " Max. Laying ft.- Bell and Spigot Pipe Bell or Flange Fastite Pipe /4".25" 2 1 4" Pipe Weight in Pounds Per Foot Plain End Per Foot Incl. Bell /4" Max. Laying Plain End 11' - 6" *16 11' - 6" Bell 12' - 0" *170 12' - 0" Mechanical 12' - 0" *170 12' - 0" Fastite 12' - 0" *170 12' - 0" Flange 11' - 6" *
20 WW Bell and Spigot Fittings WW C100 Standard Dimensions able No Class Dimensions in Inches 1 B C D E F 1 W D D D D D D B D B D B D B D B D B C D *B/D B C D *B/D B C D *B/D B C D *B/D *B/D was an MERICN designation for fittings 0" and larger having Class B socket and spigot diameters with Class D metal thickness MERICN HISORICL D OBSOLEE PIPING MERILS
21 WW Bell & Spigot Fittings Standard Bell & Bell and Bell & Spigot Bends Laying Dimensions WW C100 S S S MERICN HISORICL D OBSOLEE PIPING MERILS able No Bell & Spigot Bell & Spigot Bell & Spigot 90 Bend 45 Bend 22 1/2 Bend Bell & Bell Bell & Bell Bell & Bell 90 Bend 45 Bend 22 1/2 Bend S Bell & Spigot Bell & Spigot 11 1/4 Bend 5 5/8 Bend Bell & Bell Bell & Bell 11 1/4 Bend 5 5/8 Bend Dimensions in Inches 90 Bend 45 Bend Bend Bend Bend ( 1 4th) ( 1 8th) ( 1 16th) ( 1 2nd) ( 1 64th) S S S S S S ll fittings were furnished Bell and Bell as well as Bell and Spigot. For see able No
22 WW Bell & Spigot Fittings Standard ll Bell and Bell & Spigot ees and Crosses Laying Dimensions WW C100 able No Dimensions in Inches H J S H J S H J S x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Reducing tees and crosses in sizes up to and including 24" had same laying dimensions as straight sizes. Large diameter tees and crosses were furnished with ribs as required. For see able No MERICN HISORICL D OBSOLEE PIPING MERILS 12-21
23 WW Bell & Spigot Fittings Standard Reducers Laying Dimensions 8" 8" MERICN HISORICL D OBSOLEE PIPING MERILS able No Bell & Bell Laying (L) Large End Bell Small End Bell Dimensions in Inches Spigot Ends x * x * x * x x x x x x x x x x x x x x x x x x x x x x Bell & Bell Large End Bell *In sizes " through 24", laying length was the same for all reductions except as noted below: 4 x 2 Reducers Small End Bell had a laying length of 21 inches. 4 x 2 Reducers Bell & Bell had a laying length of 17.5 inches. 6 x 2 Reducers Bell & Bell had a laying length of 27.5 inches. 6 x Reducers Small End Bell had a laying length of 0.5 inches. 6 x Reducers Bell & Bell had a laying length of 26.5 inches. 8 x Reducers Bell & Bell had a laying length of 26.5 inches. For see able No Laying (L) Small End Bell Spigot Ends 12-22
24 MERICN Specials Caulked Joint Sleeves and Split Sleeves L L D D able No Short Long Solid Sleeve WW C100 Class D Dimensions in Inches L Short Long Split Sleeve S h o r t L o n g S h o r t L o n g S h o r t L o n g 14 D D D D D B D B D B D B D B D B D B D B D B D B Weight of Split Sleeve includes weight of side flange bolts and gaskets. Fittings were normally gray iron but were furnished of ductile iron when specified. Weight in Pounds S o l i d S l e e v e s S p l i t S l e e v e s MERICN HISORICL D OBSOLEE PIPING MERILS 12-2
25 S Short Body Bell & Spigot Fittings NSI Standard MERICN Standard MERICN HISORICL D OBSOLEE PIPING MERILS Reducer Fig. 12- MERICN furnished a complete line of Short Body Bell and Spigot Fittings per NSI and MERICN Standard as shown above. Bell and Bell as well as Bell and Spigot Fittings (including Spigot and Spigot Reducers) were furnished. he laying length dimensions and R dimensions were the same as those of the corresponding mechanical joint and flange fittings per WW C110. See Sections 5 and
26 MERICN Ductile Iron Flanged Fittings MERICN Standard Flanged Double Branch 90 Bends and Return Bends 1 2 R -080 Double Branch 90 Bend able No Pressure Rating psi C-F -080 Double Branch 90 Bend C-C Return Bend Return Bend Dimensions in inches Dimensions in inches Weight lb R C-C C-F Weight lb Some larger size Return Bends are available. Numerals on cut indicate standard order of specifying size of fitting. See general notes on page 6-2. MERICN HISORICL D OBSOLEE PIPING MERILS 12-25
27 MERICN Flanged Fittings WW C and 45 Bends Flanges F&D to Match S B16.1 Class 125 C MERICN HISORICL D OBSOLEE PIPING MERILS able No Class Bend R R he bends listed above and in able No , as well as the other flanged fittings referenced on page 12-2, were produced with wall thicknesses and laying lengths in accordance with the WW C100 Standard. C Bend 90 Bend 45 Bend Weight lb 1 D D D D D D B D B D B D B D B D B D B D B D B D R R C Weight lb 12-26
28 MERICN Flanged Fittings WW C , and Bends Flanges F&D to Match S B16.1 Class Bend able No Class R Bend Bend Bend Bend Bend Weight lb 1 D D D D D D B D B D B D B D B D B D B D B D B D In addition to bends shown in this able and in able No , MERICN also produced WW C100 Flanged ees, Crosses and Reducers which had the same laying length dimensions as the WW ll Bell Fittings listed in able Nos and R Weight lb R Weight lb MERICN HISORICL D OBSOLEE PIPING MERILS 12-27
29 Mechanical Joint/Flanged and Long PE 90 Bends MERICN Standard MERICN HISORICL D OBSOLEE PIPING MERILS able No Pressure Rating psi Iron Strength psi (1000's) hese bends were furnished with lugs as indicated when specified. Dimensions in Inches S Weight in Pounds -11 MJ & PE -411 Flg & PE 12-28
30 MERICN Ductile Iron Flanged Fittings NSI B16.1 Class 25 and Class 250 F&D Flanges NSI B16.1 covers both threaded flanges and flanged fittings for general service at ambient and elevated temperatures. he pressure ratings set forth are not primarily for water or other liquid service as are those in WW C110. NSI B16.1 flanges and fittings are referenced here only for dimensional information. Fittings: Class 25 MERICN manufactures flanged fittings to the strength requirements of WW C110 and with standard C110 flanges except with drilling to match the NSI B16.1 Class 25 flanges when specified. able No O.D. Dia. of Flange Flanges, Bolts and Gaskets Standard Dimensions Class 25 hickness* B.C. Dia.of Bolt Circle Dimensions in inches Bolts No. Per Joint x x x x x x x x x x x x x x x x x x x x x x x x x x x x 55 8 *hickness furnished is the same as WW C110 flange. Bolt Hole Diameter of Ring Gasket MERICN HISORICL D OBSOLEE PIPING MERILS 12-29
31 MERICN Ductile Iron Flanged Fittings NSI B16.1 Class 25 and Class 250 F&D Flanges Continued MERICN HISORICL D OBSOLEE PIPING MERILS Fittings: Class 250 MERICN manufactures a limited number of special fittings in accordance with WW C110 except with laying dimensions per NSI B16.1 Class 250 and with flanges faced and drilled to match the Class 250 flanges. MERICN does not manufacture any fittings to the requirements of NSI B16.1 as listed in the following tables except for laying dimensions and facing and drilling as specifically noted. able No O.D. Dia. of Flange Flanges, Bolts and Gaskets Standard Dimensions Class 250 hickness B.C x x x x x 4 8 B.C. Dia. of Bolt Circle Dimensions in Inches Dia. of Raised Face NSI B16.1 Class 250 Flanges have 0.06" raised face; this raised face is included in center-to-face and face-to-face dimensions. hese B16.1 Class 250 Flanges can be furnished special without raised face; when so required, flanges should be specified faced and drilled NSI B16.1 Class 250, except flat faced. On special order, MERICN furnishes pipe and fittings in some but not all sizes with flanges faced and drilled NSI B16.1 Class 250. Drilling of flanges can be rotated when required; for those sizes with an even number of bolt holes in each quadrant, fitting can be rotated 45 with standard drilling. Bolts No. Per Joint x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 58 4 O.D. Bolt Hole Diameter of Ring Gasket 12-0
32 MERICN Ductile Iron Flanged Fittings NSI B16.1 Dimensions of Class 250 Flanged Fittings B C B C able No Nominal Pipe F Center to Face 90 Bend, ees, Crosses, & rue "Y" B Center to Face 90 Long Radius Bend F Straight Fittings C Center to Face 45 Bend D Center to Face Lateral E Short Center to Face rue "Y" and Lateral F Face to Face Reducer of Branch and Smaller on Branch Reducing (Short Body) ees, Crosses H Center to Face Run J Center to Face Outlet or Side Outlet ll - reducing - tees and crosses - sizes - 16 and smaller - shall -have same center-to-face - - dimensions as straight - size -fit tings, - corresponding - -to the -size of the - largest opening E D E H H D J MERICN HISORICL D OBSOLEE PIPING MERILS 12-1
33 MERICN Ductile Iron Flanged Fittings NSI B16.1 Dimensions of Class 250 Flanged Fittings Continued H H H H H H J J J H H J J J MERICN HISORICL D OBSOLEE PIPING MERILS able 12-2 Continued Nominal Pipe H H of Branch and Smaller J Reducing (Short Body) Laterals M Center to Face Run M N R N Center to Face Run S P Center to Face Branch P R Center to Base S Dia. of Round Base Base Bends and Base ees hickness of Base U hickness of Ribs of Support -ing Pipe for Base Base Drilling W Bolt Circle Dia. of Holes ll reducing lateral sizes and smaller - shall - have same - center-to-face - - dimensions as straight - size - fittings, corresponding - - to the - size -of the -largest-opening W M N P R S 12-2
34 MERICN Ductile Iron Flanged Fittings NSI B16.1 hreaded Companion Flanges and Blind Flanges Class 250 X Q Y able No. 12- Nominal Pipe I W O 0.06" MX. Flat 8" and Smaller O Dia. of Flange Q hickness of Flange (Min) Q W O -881 Ductile Companion Flange (for Steel Pipe O.D.) W Dia. of Raised -880 Blind Flanges -880 Blind Flanges I Dia. of Port 0.06" Raised Face V Wall hickness II W O V Dished 10" and Larger X Dia. Hub (Min) * * * *Fittings in these sizes are not produced and used in sufficient quantities to warrant standardization; however, the flange dimensions are included for convenience where special fittings larger than 0 are required. ll Blind Flanges for sizes 10 and larger must be dished with inside radius equal to the port diameter. Companion Flanges are furnished of ductile iron only and are threaded for fabrication on pipe of standard steel pipe outside diameter unless specified otherwise. See Section 8 for Companion Flange F&D NSI B16.1 Class 250 for threading on ductile iron pipe. Q -881 Companion Flanges Y hrough Hub of hreads MERICN HISORICL D OBSOLEE PIPING MERILS 12-
35 MERICN Mechanical Joint Fittings NSI/WW C110/21.10 Offsets MERICN HISORICL D OBSOLEE PIPING MERILS able No Pressure Rating psi Iron Strength psi (1000's) D * *14 50 DI * *14 50 DI * *14 50 DI * *4 50 DI * *16 50 DI * *16 50 DI * *16 50 DI * *6 50 DI * *18 50 DI * *18 50 DI * *18 50 DI * *10 50 DI * *10 50 DI * *10 50 DI * *10 50 DI * *12 50 DI * *12 50 DI * *12 50 DI *Not included in WW C110. he user is directed to "off-set capabilities" of deflected pipe and fitting joints as shown elsewhere in this manual. L MJ & MJ Weight lb L MJ & PE Weight lb 12-4
Mechanical joint fittings
30"-48" Mechanical joint fittings Ductile Iron - c110 For Water & Wastewater, Fire rotection & Industrial pplications 866.DI.IE 2 able of Contents Mechanical Joint Fittings 3 Standard Mechanical Joint
More information2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61
30"-64" Ductile Iron industrial Applications, water & Wastewater 2 Table of Contents Flanged Fittings for Water 3 Flange Details 5 Flanged Fittings 6 90º and 45º Bend 6 22-1/2º and 11-1/4º Bends 7 Tees
More informationAMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids
AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids The AMERICAN Mechanical Joint was developed by the American Cast Iron Pipe Company and first marketed in 1929. Since that time, millions
More informationDUCTILE IRON PIPE JOINTS AND THEIR USES
DUCTILE IRON PIPE JOINTS AND THEIR USES Ductile Iron Pipe Joints and Their Uses By Richard W. Bonds, P.E. DIPRA Research and Technical Director Introduction Joints for Iron pipe have come a long way. About
More informationSection 3. AMERICAN Ductile Iron Pipe
Section 3 AMERICAN Ductile Iron Pipe AMERICAN Ductile Iron Pipe Centrifugally Cast in Metal Molds or Sand-Lined Molds For Water or Other Liquids. What is AMERICAN Ductile Iron? The ideal of cast iron with
More informationDESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES
SECTION INCLUDES Domestic Water Fire Water Service Water Well Sanitary Sewer Storm Drains Foundation Drainage RELATED SECTIONS 03 30 00 Concrete 21 00 00 Fire Suppression - Sprinklers 22 00 00 Plumbing
More informationSECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work
More informationSECTION 15105 DUCTILE IRON PIPE AND FITTINGS
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
More informationSUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationEXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
More informationBeacon Hill Sewer District Standard Specifications
Beacon Hill Sewer District Standard Specifications Residential Gravity Side Sewer Including Design Criteria and Standard Construction Drawings Residential Gravity Side Sewer Design Criteria 1. Provisions
More informationSECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
More informationDuctile Iron Pipe Couplings
J-9 Pipe 1 2 Straight and Transition Ductile offer an easy and economical way of joining whether the is of the same nominal and/or type or different at each coupling. couplings will handle most of your
More informationSANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
More informationSection C-1 Pipes and Fittings
Section C-1 Pipes and Fittings C1.00 Work Included The work under this Division of the Specifications shall include all labor, materials, and equipment necessary to furnish and install all piping, pipelines,
More informationThe work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
More informationINDEX. Sec. No. Items Page Nos.
INDEX Sec. No. Items Page Nos. 1. Types of Pipe............... MSSP- 2 2. Concrete Pipe............... MSSP- 2 thru MSSP-3 3. ABS and PVC Truss Pipe............... MSSP- 3 4. ABS and PVC Solid Wall Pipe...............
More informationTECHNICAL SPECIFICATION
THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,
More informationGeneral Guidelines for Repairing Buried PE Potable Water Pressure Pipes
515 General Guidelines for Repairing Buried PE Potable Water Pressure Pipes Introduction Traditional piping systems have gasket-sealed bell and spigot joints every 20 feet, which can be a potential maintenance
More informationState of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
More informationCaps STANDARD WEIGHT Inches / Pounds
Standard Caps you are here: Home > Weldbend Catalog > Fittings > Caps Caps STANDARD WEIGHT Inches / Pounds For Metric Units >Click Here Nominal Pipe Size Outside Inside Wall Thickness (T) Length (E) Pipe
More informationModel Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer
Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer The user may choose to adopt part or all of this Model Specification; however, the user should ensure that all parts
More informationAIR RELEASE, CLEANOUT, AND SEWER MANHOLES
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing
More informationSECTION 02401 - SANITARY SEWER PIPE
PART 1 - GENERAL 1.1 DESCRIPTION A. The WORK under this Section includes providing all labor, materials, tools and equipment necessary for furnishing and installing sanitary sewer pipe, in accordance with
More informationDIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
More informationSECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
More informationWastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
More informationSECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
More informationSECTION 15056 DUCTILE-IRON PIPE AND FITTINGS
SECTION 15056 PART 1 GENERAL 1.01 DESCRIPTION This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems. A written request to use Ductile
More informationWATER & SEWER CORROSIVE RESISTANT PRODUCTS
WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING
More informationASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe
More informationSection 02415. Installation of pipe and casing for sanitary sewer by methods of augering.
ITY OF PRLN UGRING PIP OR SING FOR SWRS Section 02415 UGRING PIP OR SING FOR SWRS 1.0 G N R L 1.01 STION INLUS Installation of pipe and casing for sanitary sewer by methods of augering. References to Technical
More informationValve Live Loading With Belleville Springs. Belleville Springs for Valve Live Loading
Valve Live Loading With Belleville Springs What is Valve Live Loading? The addition of Belleville Springs to the gland follower studs to maintain the packing load of the valve over time. What s In The
More informationSECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
More informationSECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
More informationTelescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001
Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001 Telescoping Post Indicator 2945 A 1" SQUARE STEM 9" MAX. = 10" MIN. = 7" FIELD ADJUSTMENT INSTRUCTIONS 1. Remove the top section from
More informationConduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More informationSeries 4000 Fiberglass Pipe and Fittings
Series 4000 Fiberglass Pipe and Fittings for corrosive industrial service Uses and applications Listings Performance Acid drains Chemical process piping Corrosive slurries Food processing Geothermal Nonoxidizing
More informationSECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
More informationSECTION 16402 UNDERGROUND ELECTRIC SERVICE
SECTION 16402 UNDERGROUND ELECTRIC SERVICE PART 1 GENERAL 1.1 SUMMARY A. Description of System 1. Furnish all labor, materials, and equipment for below grade work external to buildings as required, and
More informationJCM GENERAL PRODUCT DIRECTORY Effective March 1, 2010 Replaces 01/12/2007
JCM GENERAL PRODUCT DIRECTORY Effective March 1, 20 Replaces 01//2007 UNIVERSAL CLAMP COUPLINGS / REPAIR FITTINGS Page 1 Universal Clamp Coupling - Standard Range...4-2 Universal Clamp Coupling - Extended
More informationFabricated Drainage Products
Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage
More information32-02.05 Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.
SECTION 32: SANITARY SEWER INSTALLATION 32-01 SCOPE. The Work shall consist of furnishing and installing sewer mains, manholes, laterals, cleanout fittings and appurtenances; and testing, flushing and
More informationFlygt Ball Check Valves
4/13 Supersedes: 6/96 The basic purpose of a check valve is to permit flow in one direction, prevent flow in the opposite direction and perform this function automatically and with minimum maintenance.
More informationSection 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
More informationNote: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.
CHANNEL DrAiNS Durable Designed for maximum durability and drainage, NDS Channel Drains are a proven alternative to traditional concrete drains. UV inhibitors in the grates, channel and component parts
More informationSERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
More informationFY08 SEWER POINT REPAIRS BID TABULATION
6-07-831 Page 1 of 12 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING "
More informationSECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS
SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1: GENERAL 1.01 SECTION INCLUDES Furnishing and installing up to 16-inch high density polyethylene (HDPE) pipe and fittings for
More informationRING JOINT SYSTEMS 207
RING JOINT SYSTEMS 07 08 Table of Contents Model R-88 Pages 10-11 Model R-88 Large Diameter Page 1 Model RH-1000 1000 PSI Coupling Page 13 Model RX-3000 3000 PSI Coupling Page 1 Model RX-3770 3770 PSI
More informationMueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.
Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,
More informationSECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL
SECTION 02110 - ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL PART 1 - GENERAL 1.1 WORK INCLUDED IN THIS SECTION A. The WORK of this Section includes the repair, demolition, and disposal of asbestos
More informationMechanical Joint Restraints
-15 PVC Pipe Restrainer The PVC mechanical joint restrainer eliminates the need for thrust blocking, tie rodding, or harnessing mechanical joint fittings when they are used with PVC pipe. The key to the
More informationPrice List January 1, 2015
Price List January 1, 2015 Cement Lined Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15
More informationINDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED
INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED Available in Sizes B C D E See Page 6 for Dimensions Kennedy Valve/Indicator Posts 17-1 INDICATOR POST STYLE 2945 A TELESCOPING
More informationSECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.
SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings
More informationCALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04
BROWN MINNEAPOLIS TANK PAGE 1 OF 7 PURPOSE: Create and Drawing Uniformity Create, explain, and establish a standard bill of materials to be placed on every drawing (except the overall tank elevation and
More informationSECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING
SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent
More informationASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.
SECTION 3000 - SANITARY SEWERS 3001 SCOPE. This section applies to sanitary sewer construction and shall consist of furnishing all labor, materials, and equipment for the complete installation of sewers
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS
San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS 854.1 DESCRIPTION: This item shall govern sanitary sewer laterals installed in accordance with these
More informationSECTION 724 PIPE CULVERTS
SECTION 724 PIPE CULVERTS 724.1 Description. This work shall consist of providing pipe or pipe arch of the diameter or shape designated, laid upon a firm bed and backfilled as specified. Where appropriate
More informationPIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
More informationOwner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
More informationBethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL
155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS
More informationSECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
More informationSECTION 603 SANITARY SEWER FORCE MAINS
SECTION 603 SANITARY SEWER FORCE MAINS 1. GENERAL Pipelines for sanitary sewer force main systems shall conform to the following specifications and shall be installed at the locations indicated on the
More informationSTANDARD SPECIFICATION SECTION 15292 POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900)
STANDARD SPECIFICATION SECTION 15292 POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900) PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of PVC pressure pipe
More informationDIVISION 4300 STORM DRAINAGE
DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES
More informationSECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
More informationPipe Repair Products A complete selection for all types of pipe
Pipe Repair Products A complete selection for all types of pipe Mueller Service Saddles Manufactured and tested in accordance with ANSI/AWWA C800 & NSF 61 certified. Mueller service saddles, available
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationMueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION
Mueller Pipe Repair Products A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION MUELLER STAINLESS STEEL REPAIR CLAMPS Mueller offers a full line of stainless
More informationV47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
More informationTECHNICAL SPECIFICATIONS GRAVITY AND PRESSURE SEWER LINE AND MATERIALS
TECHNICAL SPECIFICATIONS GRAVITY AND PRESSURE SEWER LINE AND MATERIALS Scope of Work Work performed under this contract shall consist of furnishing and installing, complete and ready for service, the sewer
More informationSECTION 9 AMERICAN. Restrained Joint Pipe
SECTION 9 AMERICAN Restrained Joint Pipe AMERICAN Restrained Joint Pipe The principal standards relating to applicable features of AMERICAN Restrained Joint Pipe and Fittings are ANSI/AWWA C151/A21.51,
More informationSECTION 15064 PVC PRESSURE PIPE AWWA C900
SECTION 15064 PVC PRESSURE PIPE (AWWA C900) PART 1 GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of polyvinyl chloride (PVC) pressure pipe conforming to AWWA C900.
More information3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.
The following shall serve as the minimum requirements for contractors performing work in relation to the Authority s potable water and sanitary sewer system(s), appurtenances and service connections. General:
More informationCLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS
CLEANOUT FEATURES KLEENATRON II Features JOSAM KLEENATRON II Cleanouts incorporate features developed to meet the latest in building construction methods. These features ensure the specifier, installer
More informationTYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
More informationQuality & Innovation, Manufactured in the U.S.A.
Quality & Innovation, Manufactured in the U.S.A. Repair Clamps Couplings Expansion Joints Pipe Restraint Service Saddles Dismantling Joints Tapping Sleeves Tapping Machines HDPE Pipe Products Line-Stop
More informationMueller B-101 and A-3 Drilling and Tapping Machines
TM TM Mueller and Drilling and Tapping Machines A guide to selecting Mueller Equipment Mueller TM TM and Drilling and Tapping Machines When it comes to line stopping and drilling and tapping technology
More informationPROTECTO 401 Price List
Price List January 1, 2015 Protecto 401 Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15
More informationDESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4
DESCRIPTION PAGE B7 Studs and Nuts Stud Bolts for Pressure-Temperature Piping 2-1 General Purpose End-to-End Studs 2-2 Tap End Stud Bolts 2-3 Double End Stud Bolts 2-4 Sigma Fasteners, Inc. Section 2 STUD
More information8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P-24258 B-24258 E-24259 B-24259 B-24266 B-24267
BALL ANGLE METER VALVES - 3/4" & " 8D. B-24258 MUELLER 300 Ball Angle Meter Valve MUELLER 0 Conductive Compression Connection for CTS O.D.* tubing x meter swivel nut** adding -3 suffix to catalog number.
More informationCharts (Section XI) www.accordintl.com Ph. (713) 641-2288 Fax (713) 641-3636 Main PAGE #
Charts (Section XI) Part No. Description Page No. Fraction, Decimal, and Millimeter Conversion Chart 2 Measurement Chart (Metric & Standard) 3 Standard (ANSI B16.5) Flange Dimension Chart 4 Metric Flange
More informationIt's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool
It's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool H Craft Print Project No. 272 ERE'S a metal bender that will enable you to bend
More informationSTANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY
STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY Approved and adopted as Official Document Number 800576 this 10th day of December, 1980 Donald R. Boyd, P.E., Director Water
More informationSEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT
SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT The following are minimum requirements for installation of conventional trench sewage disposal systems in St. Mary s County,
More informationMACHINE DRAWING QUESTION BANK. 2. What are the parts not usually sectioned? (Nov 04)
MACHINE DRAWING QUESTION BANK UNIT-I 1. Answer the following: Sketch a i. Hexagonal nut convention, ii. Convention of a stud bolt. (Nov 04) 2. What are the parts not usually sectioned? (Nov 04) 3 Answer
More informationSECTION 300 SANITARY SEWER CONSTRUCTION SPECIFICATIONS
SECTION 300 SANITARY SEWER CONSTRUCTION SPECIFICATIONS 300-1 SECTION 300 TABLE OF CONTENTS SECTION TITLE PAGE 300 GENERAL 300-3 301 DEFINITIONS 300-3 302 REFERENCES 300-3 303 RECEIVING, HANDLING, AND STORAGE
More informationHigh Density Polyethylene Liners for Rehabilitation of Corroded Pipelines
High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines Jeff Schell General Manager United Pipeline Middle East, Inc. Introduction HDPE Liners A cost effective and environmentally beneficial
More informationCHAPTER 6 - SANITARY SEWER
CHAPTER 6 - SANITARY SEWER 6.1 GENERAL This section covers the requirements for PVC plastic sewer pipe materials and installation in sanitary sewer construction. 6.2 PIPE PVC gravity sewer pipe and fittings
More informationAmerican National, Unified Screw Threads
C h a p t e r 9 American National, Unified Screw Threads In this chapter, you will learn the following to World Class standards:! Why Use Fasteners! The Text Designation for the Unified National Thread!
More informationSECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily
More informationNEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp
Repair and Construction. Complete stainless steel pipe repair clamps to repair cracks, fractures, pin holes, torn sockets or welded tees, broken asbest-cement pipe coupling and more. Available for all
More informationHIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE
Electrical Conduit & Fittings Catalog HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE Payment Terms: Payment terms are printed on every invoice. Invoices not paid in full by the net due
More informationThese features have made Lo Torc valves the choice of high pressure plug value users, worldwide:
LO TORC Plug Valve The high value, dependable performance, and low maintenance requirements of Halliburton Lo Torc valves can help reduce overall operating costs and help cut downtime. These features have
More information