1 30"-48" Mechanical joint fittings Ductile Iron - c110 For Water & Wastewater, Fire rotection & Industrial pplications
2 866.DI.IE 2 able of Contents Mechanical Joint Fittings 3 Standard Mechanical Joint Dimensions 4 lain End Dimensions 5 90º Bends 6 45º Bends º Bends º Bends 9 ees and Crosses 10 Base Bends 12 Base ees 13 Base Drilling Details for Base Bends and Base ees 14 Reducers 15 Solid Sleeves 16 Connecting ieces, One End Flanged 17 Caps and lugs 18 Wye Branches 19 roducts for Water, Wastewater and Fire rotection 20 U.S. IE ND FOUNDRY CO.
3 866.DI.IE 3 Mechanical Joint Fittings U.S. ipe s C110 Mechanical Joint Fittings are available in 30 through 48 sizes. Wye branches are not covered by C110/21.10, are made to U.S. ipe Standards and meet all applicable wall thickness and strength requirement of NSI/WW C110/ Caps, plugs and sleeves are not furnished with cement-mortar linings. For special conditions, Mechanical Joint Fittings with special coatings and/or linings can be supplied. Glands, bolts and gaskets are required in sufficient quantities for each socket opening. he weights of these accessories are not included in the fittings weights shown herein. NSI /WW Standards NSI/WW C110/21.10, Ductile-Iron and Gray-Iron Fittings for Water NSI/WW C111/21.11, Rubber Gasket Joints for Ductile-Iron ressure ipe and Fittings. Mechanical Joint Fittings and accessories are made to meet all applicable requirements of NSI/WW C110/21.10, 3 through 48 and NSI/WW C111/ NSI/WW C104/.21.4, Cement-Mortar Lining for Ductile-Iron ipe and Fittings for Water. Fittings are cement-mortar lined and coated with an asphaltic material, inside and outside, in accordance with NSI/WW C104/21.4. Note: If specifiers and users believe that corrosive soils will be encountered where our products are to be installed, please refer to NSI/WW C105/ 21.5 olyethylene Encasement for Ductile ipe Systems for proper external protection procedures. U.S. IE ND FOUNDRY CO.
4 866.DI.IE 4 Standard Mechanical Joint Dimensions M L S K 2 J B K 1 Size Inches lain End Dimensions Inches Bolts WEIGH ounds a B J K 1 K 2 L M S QY. Size Length Bell gland Bolts gasket / / / / / / / / / / / / / / / / / / / he bolt holes in the fitting flanges straddle the vertical center line when the fitting is positioned to change the fluid flow in a horizontal direction. U.S. IE ND FOUNDRY CO.
5 866.DI.IE 5 lain End Dimensions Bottom of socket 8 added laying length Diameter for 8 minimum length Diameter for 5-1/2 minimum length ll sizes For For 3-12 Diameter sizes dimensions Weight Inches Inches ounds a t lain End NOE: Bell contour shown indicates bottom of socket in a standard all bell fitting. U.S. IE ND FOUNDRY CO.
6 866.DI.IE 6 90º Bends R R S MJ and MJ MJ and E SIZE ressure Rating Dimensions Weight Inches psi Inches ounds For dimensions of Mechanical Joints see page 4. For dimensions of plain ends see page 5. t a s r MJ & MJ MJ & E U.S. IE ND FOUNDRY CO.
7 866.DI.IE 7 45º Bends R MJ and MJ R MJ and E SIZE ressure Rating Dimensions Weight Inches psi Inches ounds t a s r MJ & MJ MJ & E For dimensions of Mechanical Joints see page 4. For dimensions of plain ends see page 5. U.S. IE ND FOUNDRY CO.
8 866.DI.IE º Bends S R R MJ and MJ MJ and E SIZE ressure Rating Dimensions Weight Inches psi Inches ounds t a s r MJ & MJ MJ & E For dimensions of Mechanical Joints see page 4. For dimensions of plain ends see page 5. U.S. IE ND FOUNDRY CO.
9 866.DI.IE º Bends S R R MJ and MJ MJ and E SIZE ressure Rating Dimensions Weight Inches psi Inches ounds t a s r MJ & MJ MJ & E For dimensions of Mechanical Joints see page 4. For dimensions of plain ends see page 5. U.S. IE ND FOUNDRY CO.
10 866.DI.IE 10 ees and Crosses CROSSES EES 1 J 1 J J H ll MJ H H ll MJ H Size ressure Rating Dimensions Weight Inches psi Inches ounds Run Branch 1 H J tees all MJ Crosses all mj NOE: Flanged outlets can be furnished on a variety of Mechanical Joint ees. For dimensions of Mechanical Joints see page 4. U.S. IE ND FOUNDRY CO.
11 866.DI.IE 11 ees and Crosses (cont.) Size ressure Rating Dimensions Weight Inches psi Inches ounds Run Branch 1 H J tees all MJ Crosses all mj NOE: Flanged outlets can be furnished on a variety of Mechanical Joint ees. For dimensions of Mechanical Joints see page 4. U.S. IE ND FOUNDRY CO.
12 866.DI.IE 12 Base Bends R U R U S MJ and MJ S MJ and E Size ressure rting dimensions Weight Inches psi Inches ounds Dimension R is a finished dimension; unfinished bases will be 1/8 longer. For base drilling see page 14. For other dimensions see table of Mechanical Joint 90º bends on page 6. r s DIMEEr t u MJ & MJ MJ & E base only U.S. IE ND FOUNDRY CO.
13 866.DI.IE 13 Base ees R U S ll MJ Size ressure rting D dimensions Weight Inches psi Inches ounds r s DIMEEr t u MJ & MJ base only Dimension R is a finished dimension; unfinished bases will be 1/8 longer. For base drilling see page 14. For other dimensions see table of Mechanical Joint ees and Crosses starting on page 10. U.S. IE ND FOUNDRY CO.
14 866.DI.IE 14 Base Drilling Details for Base Bends and Base ees Size fitting D dimensions Inches Inches BC Bolt Circle Bolt Hole Number / / / / /8 4 U.S. IE ND FOUNDRY CO.
15 866.DI.IE 15 Reducers L L L MJ and MJ 1 Large End MJ 1 Small End MJ 1 Size ressure Rating hickness MJ and MJ Small End MJ Large End MJ Inches psi Inches Large Small 1 L Weight L Weight L Weight Inches ounds Inches ounds Inches ounds For dimensions of Mechanical Joints see page 4. For dimensions of plain ends see page 5. Eccentric reducers with the same dimensions and weights given for concentric reducers are available when specified on the purchase order. U.S. IE ND FOUNDRY CO.
16 866.DI.IE 16 Solid Sleeves L p ressure Solid Size Rating t l p Weight Inches psi Inches Inches ounds For dimensions of Mechanical Joints see page 4. We do not manufacture Split Sleeves. Our local sales office can obtain dimensions and prices for Split Sleeves produced by other manufacturers. U.S. IE ND FOUNDRY CO.
17 866.DI.IE 17 Connecting ieces, One End Flanged 10 for size 12 for size MJ and Flange Size ressure Rating Weight Inches psi Inches ounds For dimensions of Mechanical Joints see page 4. For dimensions of plain ends see page 5. For dimensions of flanges see page 4 in the Flanged Fittings brochure. MJ & Flange U.S. IE ND FOUNDRY CO.
18 866.DI.IE 18 Caps and lugs C LUGS caps lugs size ressure Rating Weight Dimensions Weight Inches psi Inches ounds Inches ounds U.S. IE ND FOUNDRY CO.
19 866.DI.IE 19 Wye Branches C B size ressure Rating Dimensions Weight Inches psi Inches ounds For dimensions of Mechanical Joints see page 4. Wall hickness Run Branch Run Branch B C U.S. IE ND FOUNDRY CO.
20 866.DI.IE 20 roducts for Water, Wastewater and Fire rotection Ductile Iron ipe YON JOIN ipe Mechanical Joint ipe R FLEX ipe H LOK ipe Flanged ipe Grooved ipe USIFLEX Boltless Ball Joint ipe For Subaqueous Installations SIZE RNGE 4"-64" Ductile Iron 4"-12" Ductile Iron 4"-36" Ductile Iron 30"-64" Ductile Iron 3"-64" Ductile Iron 4-36 Ductile Iron 4"-48" Ductile Iron Restrained Joints R FLEX Restrained Joint 4"-36" Ductile Iron H LOK Restrained Joint 30"-64" Ductile Iron MJ FIELD LOK Gaskets 4"-24" FIELD LOK 350 Gaskets 4"-24" FIELD LOK Gasket 30" & 36" R FLEX GRIER Rings 4"-36" Ductile Iron R ELE FLEX ssemblies 4"-24" Ductile Iron Fittings YON Fittings RIM YON Fittings R FLEX Fittings and R FLEX elescoping Sleeves H LOK Fittings and H LOK elescoping Sleeves Mechanical Joint Fittings Flanged Fittings XR FLEX Couplings 14"-24" Ductile Iron 4-12 Ductile Iron 4"-36" Ductile Iron Ductile Iron 30"-48" Ductile Iron 30"-64" Ductile Iron 4"-24" Ductile Iron Miscellaneous roducts ROECO 401 Lined Ductile Iron ipe for 4"-64" Ductile Iron Domestic Sewage and Industrial Wastes GLSS Lined Ductile Iron ipe for Wastewater reatment lants 4-30 Ductile Iron RING FLNGE-YE Gaskets 4"-36" FULL FCE FLNGE-YE Gaskets 4"-64" MJ Harness-Lok 4-48 Ductile Iron Saddle Outlets Various Ductile Iron Welded Outlets Various Ductile Iron olyethylene Encasement 4"-64" Our products are manufactured in conformance with National Standards so that our customers may be assured of getting the performance and longevity they expect. Use of accessories or other appurtenances that do not comply with recognized standards may jeopardize the performance and longevity of the project. U.S. IE ND FOUNDRY CO.
21 REGIONL SLES OFFICES ESERN REGIONL OFFICE (609) (hone) (609) (Fax) WESERN REGIONL OFFICE (815) (hone) (815) (Fax) CIFIC COS REGIONL OFFICE (510) (hone) (510) (Fax) SOUHERN REGIONL OFFICE (205) (hone) (205) (Fax) INERNIONL SLES OFFICE (205) (hone) (205) (Fax) ll U.S. ipe brochures and/or products are subject to change without further notice..o. Box Birmingham, L DI.IE ( ) FX
2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61
30"-64" Ductile Iron industrial Applications, water & Wastewater 2 Table of Contents Flanged Fittings for Water 3 Flange Details 5 Flanged Fittings 6 90º and 45º Bend 6 22-1/2º and 11-1/4º Bends 7 Tees
More informationPOLYETHYLENE ENCASEMENT
FOR DUCTILE IRON PIPE FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS P2 Table of Contents Polyethylene Encasement 3 Installation Instructions 4 Products for Water, Wastewater and Fire
More informationFULL FACE FLANGE-TYTE Gasket FOR FLANGED JOINTS
4"-64" FULL FACE FLANGE-TYTE Gasket FOR FLANGED JOINTS NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS NSF P 2 Table of Contents Introduction 3 Pressure Performance 3 Torque Performance
More informationSECTION 15105 DUCTILE IRON PIPE AND FITTINGS
SECTION 15105 DUCTILE IRON PIPE AND FITTINGS PART 1 GENERAL.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of Owner facilities. Closely coordinate construction work and connections
More informationSECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS
SECTION 33 11 00.15 DUCTILE IRON PIPE AND FITTINGS PART 1: GENERAL 1.01 COORDINATION OF WORK Connection to existing pipelines may require shutdown of AW facilities. Closely coordinate construction work
More informationDUCTILE IRON PIPE JOINTS AND THEIR USES
DUCTILE IRON PIPE JOINTS AND THEIR USES Ductile Iron Pipe Joints and Their Uses By Richard W. Bonds, P.E. DIPRA Research and Technical Director Introduction Joints for Iron pipe have come a long way. About
More informationSECTION 15056 DUCTILE-IRON PIPE AND FITTINGS
SECTION 15056 PART 1 GENERAL 1.01 DESCRIPTION This section includes materials and installation of ductile-iron pipe and fittings for potable and recycled water systems. A written request to use Ductile
More informationSECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
More informationAMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids
AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids The AMERICAN Mechanical Joint was developed by the American Cast Iron Pipe Company and first marketed in 1929. Since that time, millions
More informationDESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES
SECTION INCLUDES Domestic Water Fire Water Service Water Well Sanitary Sewer Storm Drains Foundation Drainage RELATED SECTIONS 03 30 00 Concrete 21 00 00 Fire Suppression - Sprinklers 22 00 00 Plumbing
More information8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P-24258 B-24258 E-24259 B-24259 B-24266 B-24267
BALL ANGLE METER VALVES - 3/4" & " 8D. B-24258 MUELLER 300 Ball Angle Meter Valve MUELLER 0 Conductive Compression Connection for CTS O.D.* tubing x meter swivel nut** adding -3 suffix to catalog number.
More informationQuality & Innovation, Manufactured in the U.S.A.
Quality & Innovation, Manufactured in the U.S.A. Repair Clamps Couplings Expansion Joints Pipe Restraint Service Saddles Dismantling Joints Tapping Sleeves Tapping Machines HDPE Pipe Products Line-Stop
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS
San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS 854.1 DESCRIPTION: This item shall govern sanitary sewer laterals installed in accordance with these
More informationPROTECTO 401 CERAMIC EPOXY LINED DUCTILE IRON PIPE AND FITTINGS
CERAMIC EPOXY LINED DUCTILE IRON PIPE AND FITTINGS FOR FORCE MAINS, GRAVITY AND INDUSTRIAL SEWER LINES P 2 Table of Contents PROTECTO 401 3 Suggested Specification For PROTECTO 401 5 Procedures for Sealing
More informationSECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
More informationSUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationCopper Meter Resetters
Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12 Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710
More informationSECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
More informationSECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
More informationWATER & SEWER CORROSIVE RESISTANT PRODUCTS
WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING
More informationSECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
More informationMueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.
Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,
More informationMueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION
Mueller Pipe Repair Products A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION MUELLER STAINLESS STEEL REPAIR CLAMPS Mueller offers a full line of stainless
More informationRING JOINT SYSTEMS 207
RING JOINT SYSTEMS 07 08 Table of Contents Model R-88 Pages 10-11 Model R-88 Large Diameter Page 1 Model RH-1000 1000 PSI Coupling Page 13 Model RX-3000 3000 PSI Coupling Page 1 Model RX-3770 3770 PSI
More informationMechanical Joint Restraints
-15 PVC Pipe Restrainer The PVC mechanical joint restrainer eliminates the need for thrust blocking, tie rodding, or harnessing mechanical joint fittings when they are used with PVC pipe. The key to the
More informationPipe Repair Products A complete selection for all types of pipe
Pipe Repair Products A complete selection for all types of pipe Mueller Service Saddles Manufactured and tested in accordance with ANSI/AWWA C800 & NSF 61 certified. Mueller service saddles, available
More informationSection C-1 Pipes and Fittings
Section C-1 Pipes and Fittings C1.00 Work Included The work under this Division of the Specifications shall include all labor, materials, and equipment necessary to furnish and install all piping, pipelines,
More informationSECTION 15064 PVC PRESSURE PIPE AWWA C900
SECTION 15064 PVC PRESSURE PIPE (AWWA C900) PART 1 GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of polyvinyl chloride (PVC) pressure pipe conforming to AWWA C900.
More informationINDEX. Sec. No. Items Page Nos.
INDEX Sec. No. Items Page Nos. 1. Types of Pipe............... MSSP- 2 2. Concrete Pipe............... MSSP- 2 thru MSSP-3 3. ABS and PVC Truss Pipe............... MSSP- 3 4. ABS and PVC Solid Wall Pipe...............
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationSTANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY
STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY Approved and adopted as Official Document Number 800576 this 10th day of December, 1980 Donald R. Boyd, P.E., Director Water
More information32-02.05 Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.
SECTION 32: SANITARY SEWER INSTALLATION 32-01 SCOPE. The Work shall consist of furnishing and installing sewer mains, manholes, laterals, cleanout fittings and appurtenances; and testing, flushing and
More informationModel Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer
Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer The user may choose to adopt part or all of this Model Specification; however, the user should ensure that all parts
More informationSECTION 02401 - SANITARY SEWER PIPE
PART 1 - GENERAL 1.1 DESCRIPTION A. The WORK under this Section includes providing all labor, materials, tools and equipment necessary for furnishing and installing sanitary sewer pipe, in accordance with
More informationStandard Specifications For Private Sewer Laterals
BUILDING SERVICES DEPARTMENT 250 Frank H. Ogawa Plaza, 2nd Floor, Oakland, CA 94612 Inspection Services: 510.238.3443 FAX: 510.238.2263 Standard Specifications For Private Sewer Laterals APPROVED MATERIALS
More informationPrice List January 1, 2015
Price List January 1, 2015 Cement Lined Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15
More informationSECTION 603 SANITARY SEWER FORCE MAINS
SECTION 603 SANITARY SEWER FORCE MAINS 1. GENERAL Pipelines for sanitary sewer force main systems shall conform to the following specifications and shall be installed at the locations indicated on the
More informationGeneral Guidelines for Repairing Buried PE Potable Water Pressure Pipes
515 General Guidelines for Repairing Buried PE Potable Water Pressure Pipes Introduction Traditional piping systems have gasket-sealed bell and spigot joints every 20 feet, which can be a potential maintenance
More informationSTANDARD SPECIFICATION SECTION 15292 POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900)
STANDARD SPECIFICATION SECTION 15292 POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900) PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of PVC pressure pipe
More informationNEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp
Repair and Construction. Complete stainless steel pipe repair clamps to repair cracks, fractures, pin holes, torn sockets or welded tees, broken asbest-cement pipe coupling and more. Available for all
More informationSECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS
SECTION 33 11 00.13 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS PART 1: GENERAL 1.01 SECTION INCLUDES Furnishing and installing up to 16-inch high density polyethylene (HDPE) pipe and fittings for
More informationDIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
More informationPVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.
CONDENSED CATALOG PVC HPB-0-A Effective 9//97 Revised //99 CLEAR / / / / -/ -/ -/ x/ CLEAR / / / / -/ PVC SDR. PSI (Water @ 7. F.) /.0.9.0.0 PVC SDR -/ -/ -/ 0 0 PVC SCHEDULE 0.0.7.0.00..7.7.00.000.00...
More informationDUCTILE IRON PIPE FOR WASTEWATER APPLICATIONS
DUCTILE IRON PIPE FOR WASTEWATER APPLICATIONS DUCTILE IRON PIPE FOR WASTEWATER APPLICATIONS The 1972 AMENDMENTS to Public Law 92-500 (the Clean Water Act) established the federal government s largest domestic
More informationSECTION 02600 - PIPELINE CONSTRUCTION
SECTION 02600 - PART 1 -- GENERAL 1.1 WORK OF THIS SECTION A. The WORK of this Section includes providing general requirements for pipelines, including pipejoints, specials, and appurtenances, complete
More informationBeacon Hill Sewer District Standard Specifications
Beacon Hill Sewer District Standard Specifications Residential Gravity Side Sewer Including Design Criteria and Standard Construction Drawings Residential Gravity Side Sewer Design Criteria 1. Provisions
More informationFY08 SEWER POINT REPAIRS BID TABULATION
6-07-831 Page 1 of 12 1 FOR CLEANING AND TELEVISING EXISTING SEWERS, AS SPECIFIED, ANY REQUIRED CLEANING, ANY LOCATION, ANY LENGTH OF SEWER, COMPLETE IN PLACE, FOR VARIOUS PIPE DIAMETERS. A. EXISTING "
More informationSection 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011
STANDARDS AND CONSTRUCTION MANUAL : Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011 PART 1 - GENERAL 1.01 SCOPE OF WORK A. These specifications cover the pipes, fittings, and appurtenances
More informationPROTECTO 401 Price List
Price List January 1, 2015 Protecto 401 Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15
More informationFord Service Saddles and Tapping Sleeves
THE FORD METER BOX COMPANY, INC. ISO 9001:2008 10002505 Section AA 02/2015 Web Revision 12/17/2015 Ford Service Saddles and Tapping Sleeves Contents Page Recommended Product Application *Steel *C900 Cast
More informationEXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
More informationSECTION 33 12 19 FIRE HYDRANTS
SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.
More informationFittings and valves. Ductile cast iron valves. for water and gas supply
Fittings and valves Ductile cast iron valves for water and gas supply 1 Valves made of ductile cast iron Reliable, saf The basis cast iron Düker places emphasis on protection: Quality and a long life cycle,
More informationSECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
More informationSECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
More informationCLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS
CLEANOUT FEATURES KLEENATRON II Features JOSAM KLEENATRON II Cleanouts incorporate features developed to meet the latest in building construction methods. These features ensure the specifier, installer
More informationARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application.
ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application. Article II provides rules governing the allowable connection to the City POTW and the construction and inspection of
More information08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
More informationBethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL
155 E. Front Street (rear) Lititz, PA 17543 Phone (717) 625-1930 Fax (717) 625-1931 Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL CONSTRUCTION SPECIFICATIONS AND DETAILS
More information4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
More information2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS
2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS Water system improvements proposed for inclusion into Western s service area shall be designed in accordance with all appropriate AWWA standards, include
More informationONTARIO P.O. Box 2849 1757 Burlington Street East Hamilton, ON L8N 3R5 Tel: (905) 547-3251 Fax: (905) 547-7369
ONTARIO P.O. Box 2849 1757 Burlington Street East Hamilton, ON L8N 3R5 Tel: (905) 547-3251 Fax: (905) 547-7369 WESTERN #1100-1200 West 73 rd Avenue Vancouver, BC V6P 6G5 Tel: (604) 737-1279 Fax: (604)
More information4 of 303 10/7/2014 12:51 PM
National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/contentfetcher?commentpara... 4 of 303 10/7/2014 12:51 PM Second Revision No. 167-NFPA 13-2014 [ Section No. 3.8.1.3
More informationMueller B-101 and A-3 Drilling and Tapping Machines
TM TM Mueller and Drilling and Tapping Machines A guide to selecting Mueller Equipment Mueller TM TM and Drilling and Tapping Machines When it comes to line stopping and drilling and tapping technology
More informationStrength and Durability for Life APPLICATIONS. Ductile Iron Pipe for Wastewater Applications
Strength and Durability for Life APPLIATIONS Ductile Iron Pipe for Wastewater Applications Last Revised: May The 72 AMENDMENTS to Public Law 2-500 (the lean Water Act) established the federal government
More informationWastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
More informationDuctile-Iron Pipe and Fittings
Ductile-Iron Pipe and Fittings AWWA MANUAL M41 Third Edition Manual of Water Supply Practices M41, Third Edition Ductile-Iron Pipe and Fittings Copyright 1996, 2003, 2009, American Water Works Association
More informationMS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water
MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org HDPE
More informationMOBILE AREA WATER AND SEWER SYSTEM. Section 12. Sanitary Sewer Standard Specifications
MOBILE AREA WATER AND SEWER SYSTEM Section 12 Sanitary Sewer Standard Specifications May 31, 2012 TABLE OF CONTENTS 12.01 SCOPE:... 5 12.02 WORK INCLUDED:... 5 12.03 PIPELINE SYSTEM MATERIALS:... 5 A.
More informationSTANDARD SPECIFICATIONS SECTION 03461 PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200
STANDARD SPECIFICATIONS SECTION 03461 PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES PART 1 - GENERAL A. Description This section includes materials, testing, and installation of precast concrete
More informationV47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
More informationA. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.
PART 1 GENERAL 1.1 SCOPE A. This item shall include the work necessary for the installation of storm sewer line construction. B. Reference Section 3800 Trenching and Backfill and the General Conditions,
More informationSTANDARD SPECIFICATIONS SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE. 1. Trenching, Backfilling, and Compacting: 02223
STANDARD SPECIFICATIONS SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE PART 1 - GENERAL A. Description This section describes materials, fabrication, installation, and testing of cement-mortar
More informationTABLE OF CONTENTS SECTION 500 SANITARY SEWER AND FORCE MAIN
TABLE OF CONTENTS SECTION 500 SANITARY SEWER AND FORCE MAIN Starts on Page 500 GENERAL... 2 501 MATERIALS... 2 502 CONSTRUCTION PROCEDURES... 7 503 ABANDONMENT OF EXISTING SANITARY SEWER FACILITIES...
More informationSECTION 03400 PRECAST CONCRETE STRUCTURES
PART 1 GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, and equipment required to install precast concrete manholes, sanitary leaching rings, pump station, valve chamber, structures, frames,
More informationGAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationLS 2540 SEWER LATERALS AND INSPECTION TEES
LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal
More informationSECTION 9 AMERICAN. Restrained Joint Pipe
SECTION 9 AMERICAN Restrained Joint Pipe AMERICAN Restrained Joint Pipe The principal standards relating to applicable features of AMERICAN Restrained Joint Pipe and Fittings are ANSI/AWWA C151/A21.51,
More informationWATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION
WATER MAIN CONSTRUCTION TECHNIQUES Overview Water Main - Materials Specifications Installation Future? Water Main Materials Material Types There are various material types used for water mains, these include:
More informationSECTION 06000 WATER DISTRIBUTION SYSTEMS TABLE OF CONTENTS
SECTION 06000 WATER DISTRIBUTION SYSTEMS TABLE OF CONTENTS 06010 WATER DISTRIBUTION PIPE A. Design B. Materials C. Installation 06020 FIRE PROTECTION A. Fire Hydrants B. Automatic Fire Sprinkler Systems
More informationBLADDER SURGE CONTROL SYSTEM
PART I GENERAL 1.01 Description BLADDER SURGE CONTROL SYSTEM This specification describes the requirements for a Bladder Surge Control System. The purpose of the system is to minimize transient pressures
More informationSERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS
1001 SOUTH LEECHBURG HILL LEECHBURG, PA 15656 Phone: 724-845-9355 Fax: 724-845-1186 SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS 1. General
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationBased on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013
SimplexGrinnell TXMAS ecommerce Ferguson Fire and Fabrication Sprinkler Price List Based on SG GSA Fire & Security Products Contract GS-07F-0396M, Mod PO-0099 January 30, 2013 Product ID Description TXMAS
More informationSANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
More informationPart VII - Water Mains and Service Laterals
ARTICLE 701 - GENERAL... 1 701.1 Definition.... 1 701.2 Description.... 1 701.3 Equipment.... 1 701.4 Tests.... 2 701.5 Finishing Work and Maintenance.... 2 701.6 Repairs and Replacement.... 2 701.7 Emergency
More information8.01 STORM SEWERS, CATCH BASIN LEADS, AND EXTENSIONS
8.01 STORM SEWERS, CATCH BASIN LEADS, AND EXTENSIONS 8.01.01 Description This work shall consist of installing lines of storm sewer pipe of the required inside diameter, and the necessary appurtenances,
More informationSECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES
SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with
More information08.08 Vic-Check Valves
The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc
More informationPIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
More informationCOPPER METER SETTERS 6-08. A.Y. McDONALD MFG. CO. WATER SERVICE PRODUCTS. TO SET 5/8", 5/8" X 3/4", 3/4", 1", 1 1/2", and 2" Water Meters
COPPER METER SETTERS TO SET 5/8", 5/8" X 3/4", 3/4", 1", 1 1/2", and 2" Water Meters A.Y. McDONALD MFG. CO. WATER SERVICE PRODUCTS 608 A.Y. M c Donald Mfg. Co. is pleased to present its extensive line
More informationSUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2016
SUMMARY OF PUBLIC WORK STANDARD SPECIFICATION REVISIONS 2016 102.5 Bid Deposits The City of Madison bid deposit form is required for all bids unless a Biennial Bid Bond is on file or check deposit is used.
More informationDRESSER TM PIPELINE SOLUTIONS
Wal-Rich Corporation is a master distributor of Dresser Pipeline Solutions, a trademark of GE. The following pages highlight the items that are in stock at our NY facility. For more information, please
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationRules and Regulations for Water Service Lines Water Services Department
Rules and Regulations for Water Service Lines Water Services Department MAY 2015 1 These regulations are established to provide for an orderly growth of the City's water system and to assure equitable
More informationSECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.
SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings
More informationDuctile Iron Pipe Couplings
J-9 Pipe 1 2 Straight and Transition Ductile offer an easy and economical way of joining whether the is of the same nominal and/or type or different at each coupling. couplings will handle most of your
More informationSuggested Specifications: Steel Pipe for Water Transmission
Suggested Specifications: Steel Pipe for Water Transmission. Suggested Specifications - Steel Pipe for Water Transmisssion Cement-mortar Lined and Tape Coated PART 1 - GENERAL 1.01 Description Scope of
More informationSeries 4000 Fiberglass Pipe and Fittings
Series 4000 Fiberglass Pipe and Fittings for corrosive industrial service Uses and applications Listings Performance Acid drains Chemical process piping Corrosive slurries Food processing Geothermal Nonoxidizing
More information