NuDAM Modules. NuDAM Modules. ND-6017 Analog Input Module, 8 channels. ND-6018 Thermocouple Input Module, 8 channels

Size: px
Start display at page:

Download "NuDAM Modules. NuDAM Modules. ND-6017 Analog Input Module, 8 channels. ND-6018 Thermocouple Input Module, 8 channels"

Transcription

1 Modules Modules ND-6017 Analog Input Module, 8 channels ND-6018 Thermocouple Input Module, 8 channels ND-6011 High-gain, Analog Input Module ND-6012 Analog Input Module ND-6013 RTD Input Module, 3 channels ND-6021 Analog Output Module ND-6050 Digital Input/Output Module ND-6052 Isolated Digital Input/Output Module ND-6060 Relay Output Module ND-6011 Counter / Frequency Input Module ND-6510 RS-485 Repeater Module ND-6520 RS-232 to RS-485 Converter Module NDP-243 Modular Power Supply ND-DLL6 : Dynamic Link Libraries for Windows 3.1, Windows 95 and Windows NT 4.0 ND-DDE6 : Dynamic Data Exchange for Windows 3.1, Windows 95 and Windows NT 4.0

2 Intelligent Remote Data Acquisition and Control Modules "A Complete Sensor to Serial Interface" T he family of Remote Data Acquisition and Control modules accepts real-world input signals that are converted to engineering units and are send, in printable ASCII characters to a controlling host computer over an RS-485 network. Most modules additionally include digital output channels that let them control real world events by producing similar digital or analog control outputs. modules are available to measure voltage, current, thermocouple, RTD and frequency. Other modules handle digital I/O or feature analog or relay output. Where applicable input isolation is 500 VRMS. modules provide direct connection to a wide variety of sensors and performs all necessary signal conditioning, scaling, linearization and conversion. Configuration is done remotely by a controlling host computer. All scaling, linearization and calibration and communications values are stored in EEPROM, eliminating the need for pots, switches or adjustment hardware. ELECTRODE FILM AGAINST NOISE modules are packaged in heavy duty ABS casings. The casings interior is coated with an electrode film to shield 's circuitry from extreme noise sources. PROTECTIVE COATING A thick protective coating, that covers both circuits and PCB, prolongs the lifetime of the modules and makes them resistant to humidity, salt spray and other harsh chemicals. Features RS-485/422 protocol, Industrial Standard Networking Two-wire multi-drop network High transfer speed (115.2 Kbps), long transfer distance (4000 ft.) Up to 256 modules on one network supervised by a single host computer Simple ASCII command/response protocol Communication is performed with printable ASCII characters Watchdog supervision of module and communication with host High voltage photo-isolators insure that fatal shocks are not passed on to other modules over the RS-485 network. Internal electrode coating against noise PCB and circuitry coating against harsh chemicals Unregulated +10 to +30 V DC to power modules` DIN rail or Wall Mount Applications Process Monitoring and Control Remote Sensing / Control Remote Data Logging Product Testing Industrial Process Control Security Control Building Automation Energy Control 7-2

3 Intelligent DA&C Modules Networking RS-232 ND-6520 RS-232 to RS-485 Converter RS-485 RS-485 NETWORKING The EIA-RS-485 protocol is a communication standard specially developped for multi-drop networks that have to communicate at high transfer rates over long distances. The RS-485 protocol is specified to communicate at rates up to 10 Mbps and over a distance of up to 4000 feet (1200 m) RS-485 uses differential transmission on a balanced pair of wires (twisted pair). The ease of wiring of twisted pair has made RS-485 the most popular and widely spread means of communication in industry. In places where strong noise still could cause interference, shielded twisted pair cabling should be used Single Segment Network Terminator NUDAM'S RS-485 IMPLEMENTATION Each module contains a halfduplex RS-485 transceiver that is used to communicate with the host computer. The quarter-unit-load of these transceivers allows up to 128 modules to be connected on a single segment without need for a repeater. To ensure error free communication, a slew rate limiter on every transceiver minimizes EMI and reduces reflections of improperly terminated cabling. Networks can be configured as single segment or multi-segment, where every trunk line is connected with a repeater to the main segment TRANSPARENT RS-485 CONTROL EQUALS HALF DUPLEX RS-232 Just a single pair of wires is needed for RS-485 since 's Repeater and Converter modules automatically sense the direction of incoming data. This allows them to correctly control the RS-485 bus direction without the need for an extra pair of handshaking wires. Data + Data - RS-485 Receiver Driver Communication Direction Switch Controller RS-485 Bus Direction Control RS-485 Receiver Driver Data + Data - Since the sensing circuitry makes RTS and CTS signals obsolete, host computer software, written for Half Duplex RS-232 communication, can be used without any modification. This means that can be integrated, without problem, into existing installations or can replace them altogether. Software Control ASCII COMMAND/RESPONSE Only the host computer can generate commands while modules can only respond. All communication between host computer and modules is performed in printable ASCII characters. Every high level programming language that supports ASCII string functions (such as C, Pascal, BASIC) can be used. modules can therefore be controlled by any type of host computer. ERROR CHECKING 's command/response protocol can add two additional characters to every string, offering the possibility to include a checksum of the string itself. This allows verification that data send was the same as data received. WATCHDOG TIMERS modules contain watchdog supervisory circuits that will automatically reset a module when the system fails. Additionally, a user programmable software timer can provide a "safe output" in case communication with the host computer or the host computer itself fails. THIRD PARTY SOFTWARE Since modules are compatible with ADAM modules, they can be substituted or mixed and matched without any problem. Next to support for popular SCADA applications such as LABtech, FIX32 and Intouch, modules come with their own DLL and DDE support for Windows 3.x, Windows 95 and Windows NT DIN-rail Mounting Panel/Wall Mounting 7-3

4 General Specifications Multichannel Analog Input Data Communication RS-485 or RS-422 protocol Maximum communication distance 4000 feet (1.2 Km) ASCII format command/ response protocol Communication error checksum checking 500 V RMS isolation Selectable baud rates : 1200 up to Kbps 256 modules per host port Up to 128 multi-drop modules on a network without repeater Protection Internal watchdog timer for module and host failure with reset or "safe output" state PCB surface coating protects against salt, spray, chemicals ABS case with internal electrode film for noise reduction Plug-in screw terminal blocks Power Requirement, Internal switching regulator Power reversal protection Environmental EMI : meets FCC class A Operating : -10 to 60 C Storage : -20 to 80 C Humidity : 5~95% Compatibility 's routing, configuration and command protocol are 100% compatible with Advantech's ADAM modules ND-6017 Analog I/O Module 8-channel ANALOG INPUT Channels : 6 differential, 2 single-ended Input Type : mv, V, and ma Input Range : ±150 mv, ±500 mv, ±1 V, ±5 V, ±10 V, ±20 ma Isolated Voltage : 500 V DC Sampling Rate : 10 samples/sec. Bandwidth : 14 Hz Accuracy : 0.1% Zero Drift : ± 6 µv/ C Span Drift : ± 25 ppm/ C CMR : 92 db ND-6018 Thermocouple Input Module 8-channel ANALOG INPUT Channels : 6 differential, 2 single-ended Input Type : Thermocouple, mv, V, ma Input Range : ±150 mv, ±500 mv, ±1 V, ±5 V, ±10 V, ±20 ma Thermocouple : J, K, T, E, R, S, B Thermocouple Input Range : J -> 0 ~ 760 C K -> 0 ~ 1,000 C T -> 100 ~ 400 C E -> 0 ~ 1,000 C R -> 500 ~ 1,750 C S -> 0 ~ 1,750 C B -> 500 ~ 1,800 C Isolated Voltage : 500 V DC Sampling Rate : 10 samples/sec. Bandwidth : 14 Hz Accuracy : 0.1% Zero Drift : ±6 µv/ C Span Drift : ±25 ppm/ C CMR : 92 db 7-4

5 Intelligent DA&C Modules Analog Input and Digital I/O RTD Input ND-6011 High Gain Analog Input Module ANALOG INPUT Type : mv, V or ma Thermocouple Input Range : J -> -200 ~ +760 C K -> -150 ~ C T -> -200 ~ +400 C E -> -100 ~ C R -> 0 ~ C S -> 0 ~ C B -> 0 ~ C Input Range : ±15 mv, ±50 mv, ±100 mv, ± 500 mv, ±1 V, ±2.5 V, and ±20 ma Sampling Rate : 10 samples/sec Accuracy : ±0.05% or better Zero Drift : ±0.03 µv / C Span Drift : ±25 ppm / C CMR : 50/ db NMR : 50/ db DIGITAL INPUT Channels : 1 (same spec. as ND-6012) DIGITAL OUTPUT Channels : 2 (same spec as ND-6012) ND-6012 Analog Input Module ANALOG INPUT Type : mv, V or ma Input Range : ±150 mv, ±500 mv, ±1 V, ±5 V, ± 10 V and ±20 ma Isolation Voltage : 1600 V RMS (1 min), 2000 V RMS (1 sec) Sampling Rate : 10 samples/sec Bandwidth : 4 Hz Accuracy : ±0.05% or better Zero Drift : ±0.03 µv / C Span Drift : ±25 ppm / C CMR : 50/ db NMR : 50/ db DIGITAL INPUT Channels : 1 Switching Levels : Low (0) -> +1 V Max. High (1) -> +3.5 V ~ +30 V Pull-up Current : 0.5 ma EVENT COUNTER Max Input Frequency : 50 Hz Max. Input Pulse Width : 0.5 msec DIGITAL OUTPUT Channels : 2 Open Collector : to 30 V, 30 ma maximum load ND-6013 RTD Input Module 3-channel ANALOG INPUTS Analog Input Type: -100 or Ni RT RTD type Temperature range -100 ~ +100 C = ~ +100 C = ~ +200 C = ~ +600 C = ~ +100 C = ~ +100 C = ~ +200 C = ~ +600 C = Ni Ni -80 ~ +100 C 0 ~ +100 C Isolation Voltage : 3000 V DC Sampling Rate : 10 samples/sec Bandwidth : 4 Hz Input Wiring : 2, 3 or 4 wires Accuracy : ±0.05% Zero Drift : ±0.3 µv / C Span Drift : ±25 ppm/ C 50/60 Hz : 150 db 50/60 Hz : 100 db 7-5

6 Analog Output Digital I/O Relay Output ND-6021 Analog Output Module ANALOG OUTPUT Voltage Output : 0~10 V Current Output : 0~20 ma, 4~20 ma Output Isolation : 1500 V DC Resolution: 12-bit output Accuracy : ±0.1% of FSR (current) ±0.2% of FSR (voltage) Zero Drift : ±0.2 µa/ C (current) ±30 µv/ C (voltage) Span Drift : ±25 ppm/ C Programmable Output Slope : to 128 ma/sec, to 64 V/sec Bandwidth: 100 samples/sec 7-6 ND-6050 Digital I/O Module Digital Input Channels : 7 Switching Levels : Low (0) -> +1 V Max. High (1) -> +3.5 V ~ +35 V Pull-up Current : 0.5 ma. Digital Output Channels : 8 Open Collector : 30 V, 30 ma max. Power Dissipation : 300 mw Power Consumption : 0.4 W ND-6052 Isolated Digital Input Module Digital Input Channels : 8 6 fully independent isolated and 2 with common ground Switching Levels : Low (0) -> +1 V maximum High (1) -> +3.5 V ~ +30 V Pull-up Current : 0.5 ma Isolated Voltage : 5,000 V RMS Input Resistance : 3K ±0.5 W power Power Consumption : 0.4 W ND-6060 Relay Output Module RELAY OUTPUTS Relay Output Channels : 4 Type : 2 Form C and 2 Form A Contact Rating : AC -> 0.6 A / 125 V, 0.3 A / 250 V DC -> 2 A / 30 V, 0.6 A / 110 V ON/OFF Interval : 3 ms / 1 ms Breakdown Voltage : 500 V Expected Lifetime : 10 8 DIGITAL INPUTS Digital Input Channels : 4 Common External Voltage : +24 V Input Type : source

7 Intelligent DA&C Modules Counter/Frequency Communication Modules ND-6080 ND-6510 ND-6520 Counter/Frequency Input Module COUNTER INPUT Channels : 2 independent 32-bit counters Input Frequency : 50 KHz Max. Input Mode : isolated or non-isolated Isolation Voltage : 2500 V RMS Isolation Input Level : logic level 0 -> +1 V (max) logic level 1 -> 5.3 V~30 V Non-isolated Input Level Programmable Threshold : logic level 0 -> 0~5 V, 0.8 V default logic level 1 -> 0~5 V, 2.4 V default Input Pulse Width : > 10 µsec Max Count : 4,294,967,295 (32-bit) Alarm: alarm comparator on each counter channel Preset Type : absolute or relative RS-485/RS-422 Repeater Input : two wire RS-485 or four wire RS-422 Output : two wire RS-485 or four wire RS-422 Speed : 1200, 2400, 4800, 9600, 19.2K, 38.4K, Kbps Power Consumption : 1 W RS-232 to RS-485/422 Converter Input : RS-232 Output : RS-485/422 Speed : 1200, 2400, 4800, 9600, 19.2K, 38.4K, Kbps Isolation Voltage : 500 V RMS Power Consumption : 1 W UP TO 256 MODULES ON AN RS-485/422 NETWORK Analog Input Thermocouple Input High-gain Analog Input Digital Input Counter/Frequency Input RTD Input FREQUENCY MEASUREMENT Range : 5 Hz ~ 50 KHz Programmable, Build-in Gate Time: 1.0 / 0.1 seconds DIGITAL OUTPUTS Channels : 2 Open collector : 30 V, 30 ma max. Power Dissipation : 300 mw Power Consumption : 0.8 W Analog Output Digital Output RS-485/422 Repeater Relay Output RS-485/422 to RS-232 Converter RS-232 RS-485 RS-422 To host computer 7-7

8 Power Supply Dimensions NDP-243 Panelmount Power Supply Input Voltage : V AC or V AC, switchable Input Frequency : 47~63 Hz Input Current : 1.4 A (max.) Short protection Output Voltage : +24 V DC ±10% Output Current : 3 A (max.) Overload Protection Dimensions : 5" (L) x 3.8" (W) x 1.6" (H) Operating Temperature : 0~50 C 7-8

9 Intelligent DA&C Modules Software and Driver Support REMOTE CONFIGURATION SOFTWARE A Windows based configuration utility is provided to easily configure and calibrate your modules. The utility supports the following functions : - Module scanning - COM port setting - Module configuration - Module calibration - Terminal emulation and Monitoring - Help screens NUDAM'S COMMAND/RESPONSE PROTOCOL There are three categories of commands. General commands --- The first category includes commands that deal with module configuration, identification, initialization. Every modules can respond to these commands. Functional commands --- these commands explicitly refer to a module's specific functions such as digital I/O, analog I/O, counting etc. Modules can only respond to commands that their hardware (and firmware) support. Special commands --- includes control of programmable watchdog timer, safe values and programmable leading codes. The only node in the network that can issue commands is the host computer. When a command has been send the host computer waits for the addressed module to respond. The majority of the commands contain destination address, command identification and data. Responses normally only contain the responding module's address and data. An example how a command/response sequence would look follows below: command : #061<CR> response : > <CR> The command orders an analog input module at address 06 (Hex) to return the value of the input data at channel 1. The module responds with V DLLs work in combination with any Windows programming language that allows DLL calls; such as Visual C/C++ and Visual Basic. DLLs (Dynamic Link Libraries) are an important aspect of Windows. A DLL contains functions that your executable program can call during execution. When your program needs a function that is not in the executable file, Windows loads the dynamic link library (the DLL), making all of its functions available to your application. 's DLL supports Windows 3.1, Windows 95 and Windows NT. NUDAM DDE SERVER To meet the open architecture of several famous Windows NT based MMI/SCADA software packages, modules come with DDE Server support. The Administration I/O DDE (Dynamic Data Exchange) server is a Window-based application program. It takes advantage of DDE, a build-in Windows communications service. This seamless software and hardware integration gives users a comprehensive solution in industrial automation. How to Link with FIX32 and InTouch The DDE server can acquire data from the modules through RS-232 serial ports and passes the data to FIX32 or InTouch via the hot link DDE server. Through the DDE protocol, FIX32 or InTouch can also pass control and configuration commands to the modules. The System Configuration is shown below. Modules RS-232 Ordering DDE SERVER D DE Excel, Database, ODBC... DDE InTouch Fix32 APPLICATION SOFTWARE DEVELOPMENT Because all commands and response are ASCII-based every high-level language (such as C, Pascal or BASIC) can be used to write application software. q ND-DLL6 : Dynamic Link Libraries for Windows 3.1, Windows 95 and Windows NT 4.0 q ND-DDE6 : Dynamic Data Exchange for Windows 3.1, Windows 95 and Windows NT 4.0 DLL Driver 's DLL (dynamic link library) is a Microsoft Windows library module that is linked to your application program at run-time. When linked, the DLL becomes part of your program, giving it additional capabilities and facilities. 7-9

10 InTouch for Process Automation FIX32 is the latest member in the Intellution FIX family of industrial automation software. FIX32 for Windows 95 and Windows NT is the worlds most popular automation solution for MMI and SCADA applications. FIX for Windows 95 and Windows NT is a true 32-bit software application written to Microsoft's Win-32 specification. FIX takes full advantage of all the powerful capabilities of Microsoft's Windows 95 and Window NT operating systems. Wonderware InTouch is an object-oriented, graphical man-machine interface (MMI) application generator for industrial automation, process control and supervisory monitoring. Types of applications include discrete, process, DCS, SCADA and other types of manufacturing environments. It is the fifth generation of the industry's leading MMI from Wonderware. One of the most significant new features, Wonderware's new pre-configured graphic "Wizards," makes the creation of powerful applications faster and easier. Object-Oriented Graphics -- Design impressive screen displays using our intuitive, object-oriented graphical user interface(gui). Real-Time and Historical Trending -- you can collect, store, and display your real-time process data. 100% Data Integrity -- you can always be assured that your process data is totally accurate. Comprehensive Reporting Via DDE -- Produce accurate, customized reports for management and regulatory agencies. Through a two-way DDE interface, you can share your process data with any DDE compatible application. Statistical Process Control (SPC) -- With SPC, you can detect out-of-spec process conditions and make appropriate adjustments before costs are incurred, maximizing product quality, minimizing product waste, and continually improving your processes. Alarming and Alarm Management User-Based Security Recipe Builder Relational Database Support Distributed, Client/Server Architecture Object-Oriented Graphics -- Easy-to-configure applications mean faster development times. Objects and groups of objects can be moved, sized and animated more quickly and simply than bit-mapped graphics. Animation Links -- Animation links may be combined to provide complex size, color, movement, and/or position changes. Animation links include discrete, analog and string touch inputs; horizontal and vertical sliders; discrete and action push buttons; show and hide window push buttons; line, fill and text color links for discrete and analog values and alarms; object height and width links; vertical and horizontal position links; vertical and horizontal percent fill links; visibility links; discrete, analog and string value output links; rotation links and blink links. Wizards -- InTouch includes a library of Wizards -- preconfigured complex objects that users can modify and duplicate freely. Real-time Or Historical Trends -- Built-in objects allow easy creation of real-time and historical trend displays. Display up to eight pens at a time in historical trend charts and have each pen reference a different historical file. 7-10

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Streamline Your Automation System with M2M Technology

Streamline Your Automation System with M2M Technology Streamline Your Automation System with M2M Technology Boundless Integration with the ADAM Remote I/O Series In order to meet the integration requirements of Environmental Monitoring Systems and Facility

More information

Straton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Straton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Straton and Zenon for Advantech ADAM-5550 Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Project Introduction: Programmable Application Controllers (PAC) are powerful and

More information

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

Intelligent RS-485 I/O expansion unit: RU-87Pn Series INTRODUCTION RU-87Pn series is a remote intelligent I/O expansion unit that used to expand i-87k series I/O modules over the RS-485 for industrial monitoring and controlling applications. There are more

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential

More information

NEW. EVEN MORE data acquisition and test stand automation

NEW. EVEN MORE data acquisition and test stand automation NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

Programmable Controller G Series. New. Models

Programmable Controller G Series. New. Models Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

EVAL-UFDC-1/UFDC-1M-16

EVAL-UFDC-1/UFDC-1M-16 Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1

More information

Optimize your simple machines... Modicon M218 Selection Guide

Optimize your simple machines... Modicon M218 Selection Guide Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,

More information

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit www.advantech.com/products.

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit www.advantech.com/products. M2M I/O Modules 14 M2M I/O Modules Overview 14-2 M2M I/O Modules Selection Guide 14-6 ADAM-2510Z Wireless Router Node 14-8 ADAM-2520Z Wireless Modbus RTU Gateway 14-9 ADAM-2031Z ADAM-2632Z ADAM-2017Z ADAM-2018Z

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

Impedance 50 (75 connectors via adapters)

Impedance 50 (75 connectors via adapters) VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

ECONseries Low Cost USB DAQ

ECONseries Low Cost USB DAQ ECONseries Low Cost USB Data Acquisition Modules ECONseries Low Cost USB DAQ The ECONseries is a flexible yet economical series of multifunction data acquisition modules. You choose the number of analog

More information

EXTERNAL DIMENSIONS AND PARTS

EXTERNAL DIMENSIONS AND PARTS FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

Process Control and Automation using Modbus Protocol

Process Control and Automation using Modbus Protocol Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

NETWORK ENABLED EQUIPMENT MONITOR

NETWORK ENABLED EQUIPMENT MONITOR NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

Eliminate Risk of Contention and Data Corruption in RS-485 Communications

Eliminate Risk of Contention and Data Corruption in RS-485 Communications I. Background and Objective Eliminate Risk of Contention and Data Corruption in RS-485 Communications Earle Foster, Jeff Hunter Sealevel Systems The RS-485 communications standard was introduced in 1983

More information

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control

More information

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a

More information

SNAP-SCM-PROFI Communication Module

SNAP-SCM-PROFI Communication Module SNAP-SCM-PROFI Communication Module Features Single isolated port with built-in DB-9 connector Baud rates to 1.5 MBaud Works with the SNAP PAC System Up to eight SNAP-SCM-PROFI modules per rack 30-month

More information

M2M/IoT Solutions. www.contec.com

M2M/IoT Solutions. www.contec.com M2M/IoT Solutions www.contec.com M2M/IoT Solutions TM Hardware Highly Reliable M2M Controllers for Various Solutions M2M Controllers Compact design available on DIN rails Low-power design using a CPU tailored

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

Digital and Analog I/O

Digital and Analog I/O 70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external

More information

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1 SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

The software beyond the climatic. Environment simulation

The software beyond the climatic. Environment simulation Spirale 2 The software beyond the climatic Environment simulation Spirale 2... Take it easy! Spirale 2 is a new software, based on a reliable system (Windows NT) and if its performances are surprising,

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

Allen-Bradley/Rockwell

Allen-Bradley/Rockwell MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

IntesisBox KNX - LON

IntesisBox KNX - LON IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111

Application Unit, MDRC AB/S 1.1, GH Q631 0030 R0111 , GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS Enhanced defect detection Built-in diagnostics for press machinery Quicker setup and easier maintenance than competitive systems Lowest monitoring cost per

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

The Answer to the 14 Most Frequently Asked Modbus Questions

The Answer to the 14 Most Frequently Asked Modbus Questions Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in

More information

LonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10

LonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10 LonManager and Protocol Analyzers Models 33100-00 and 33100-10 Description The LonManager Protocol Analyzer provides LONWORKS manufacturers, system integrators, and end-users with a rich set of Windows

More information

High Power Programmable DC Power Supplies PVS Series

High Power Programmable DC Power Supplies PVS Series Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient

More information

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode: COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

More information

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3

More information

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no

More information

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as

More information

Manual Serial PCI Cards

Manual Serial PCI Cards Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make

More information

J TB/TW Temperature limiter, temperature monitor

J TB/TW Temperature limiter, temperature monitor JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Ordering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input

More information

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction

More information

EZ-View Network Communications Guide www.cszindustrial.com

EZ-View Network Communications Guide www.cszindustrial.com Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional

More information

WIRELESS INSTRUMENTATION TECHNOLOGY

WIRELESS INSTRUMENTATION TECHNOLOGY BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Vibration analysis and monitoring Compact. Powerful. Modern technology. Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device

More information