NuDAM Modules. NuDAM Modules. ND-6017 Analog Input Module, 8 channels. ND-6018 Thermocouple Input Module, 8 channels
|
|
- Dominick Hodges
- 7 years ago
- Views:
Transcription
1 Modules Modules ND-6017 Analog Input Module, 8 channels ND-6018 Thermocouple Input Module, 8 channels ND-6011 High-gain, Analog Input Module ND-6012 Analog Input Module ND-6013 RTD Input Module, 3 channels ND-6021 Analog Output Module ND-6050 Digital Input/Output Module ND-6052 Isolated Digital Input/Output Module ND-6060 Relay Output Module ND-6011 Counter / Frequency Input Module ND-6510 RS-485 Repeater Module ND-6520 RS-232 to RS-485 Converter Module NDP-243 Modular Power Supply ND-DLL6 : Dynamic Link Libraries for Windows 3.1, Windows 95 and Windows NT 4.0 ND-DDE6 : Dynamic Data Exchange for Windows 3.1, Windows 95 and Windows NT 4.0
2 Intelligent Remote Data Acquisition and Control Modules "A Complete Sensor to Serial Interface" T he family of Remote Data Acquisition and Control modules accepts real-world input signals that are converted to engineering units and are send, in printable ASCII characters to a controlling host computer over an RS-485 network. Most modules additionally include digital output channels that let them control real world events by producing similar digital or analog control outputs. modules are available to measure voltage, current, thermocouple, RTD and frequency. Other modules handle digital I/O or feature analog or relay output. Where applicable input isolation is 500 VRMS. modules provide direct connection to a wide variety of sensors and performs all necessary signal conditioning, scaling, linearization and conversion. Configuration is done remotely by a controlling host computer. All scaling, linearization and calibration and communications values are stored in EEPROM, eliminating the need for pots, switches or adjustment hardware. ELECTRODE FILM AGAINST NOISE modules are packaged in heavy duty ABS casings. The casings interior is coated with an electrode film to shield 's circuitry from extreme noise sources. PROTECTIVE COATING A thick protective coating, that covers both circuits and PCB, prolongs the lifetime of the modules and makes them resistant to humidity, salt spray and other harsh chemicals. Features RS-485/422 protocol, Industrial Standard Networking Two-wire multi-drop network High transfer speed (115.2 Kbps), long transfer distance (4000 ft.) Up to 256 modules on one network supervised by a single host computer Simple ASCII command/response protocol Communication is performed with printable ASCII characters Watchdog supervision of module and communication with host High voltage photo-isolators insure that fatal shocks are not passed on to other modules over the RS-485 network. Internal electrode coating against noise PCB and circuitry coating against harsh chemicals Unregulated +10 to +30 V DC to power modules` DIN rail or Wall Mount Applications Process Monitoring and Control Remote Sensing / Control Remote Data Logging Product Testing Industrial Process Control Security Control Building Automation Energy Control 7-2
3 Intelligent DA&C Modules Networking RS-232 ND-6520 RS-232 to RS-485 Converter RS-485 RS-485 NETWORKING The EIA-RS-485 protocol is a communication standard specially developped for multi-drop networks that have to communicate at high transfer rates over long distances. The RS-485 protocol is specified to communicate at rates up to 10 Mbps and over a distance of up to 4000 feet (1200 m) RS-485 uses differential transmission on a balanced pair of wires (twisted pair). The ease of wiring of twisted pair has made RS-485 the most popular and widely spread means of communication in industry. In places where strong noise still could cause interference, shielded twisted pair cabling should be used Single Segment Network Terminator NUDAM'S RS-485 IMPLEMENTATION Each module contains a halfduplex RS-485 transceiver that is used to communicate with the host computer. The quarter-unit-load of these transceivers allows up to 128 modules to be connected on a single segment without need for a repeater. To ensure error free communication, a slew rate limiter on every transceiver minimizes EMI and reduces reflections of improperly terminated cabling. Networks can be configured as single segment or multi-segment, where every trunk line is connected with a repeater to the main segment TRANSPARENT RS-485 CONTROL EQUALS HALF DUPLEX RS-232 Just a single pair of wires is needed for RS-485 since 's Repeater and Converter modules automatically sense the direction of incoming data. This allows them to correctly control the RS-485 bus direction without the need for an extra pair of handshaking wires. Data + Data - RS-485 Receiver Driver Communication Direction Switch Controller RS-485 Bus Direction Control RS-485 Receiver Driver Data + Data - Since the sensing circuitry makes RTS and CTS signals obsolete, host computer software, written for Half Duplex RS-232 communication, can be used without any modification. This means that can be integrated, without problem, into existing installations or can replace them altogether. Software Control ASCII COMMAND/RESPONSE Only the host computer can generate commands while modules can only respond. All communication between host computer and modules is performed in printable ASCII characters. Every high level programming language that supports ASCII string functions (such as C, Pascal, BASIC) can be used. modules can therefore be controlled by any type of host computer. ERROR CHECKING 's command/response protocol can add two additional characters to every string, offering the possibility to include a checksum of the string itself. This allows verification that data send was the same as data received. WATCHDOG TIMERS modules contain watchdog supervisory circuits that will automatically reset a module when the system fails. Additionally, a user programmable software timer can provide a "safe output" in case communication with the host computer or the host computer itself fails. THIRD PARTY SOFTWARE Since modules are compatible with ADAM modules, they can be substituted or mixed and matched without any problem. Next to support for popular SCADA applications such as LABtech, FIX32 and Intouch, modules come with their own DLL and DDE support for Windows 3.x, Windows 95 and Windows NT DIN-rail Mounting Panel/Wall Mounting 7-3
4 General Specifications Multichannel Analog Input Data Communication RS-485 or RS-422 protocol Maximum communication distance 4000 feet (1.2 Km) ASCII format command/ response protocol Communication error checksum checking 500 V RMS isolation Selectable baud rates : 1200 up to Kbps 256 modules per host port Up to 128 multi-drop modules on a network without repeater Protection Internal watchdog timer for module and host failure with reset or "safe output" state PCB surface coating protects against salt, spray, chemicals ABS case with internal electrode film for noise reduction Plug-in screw terminal blocks Power Requirement, Internal switching regulator Power reversal protection Environmental EMI : meets FCC class A Operating : -10 to 60 C Storage : -20 to 80 C Humidity : 5~95% Compatibility 's routing, configuration and command protocol are 100% compatible with Advantech's ADAM modules ND-6017 Analog I/O Module 8-channel ANALOG INPUT Channels : 6 differential, 2 single-ended Input Type : mv, V, and ma Input Range : ±150 mv, ±500 mv, ±1 V, ±5 V, ±10 V, ±20 ma Isolated Voltage : 500 V DC Sampling Rate : 10 samples/sec. Bandwidth : 14 Hz Accuracy : 0.1% Zero Drift : ± 6 µv/ C Span Drift : ± 25 ppm/ C CMR : 92 db ND-6018 Thermocouple Input Module 8-channel ANALOG INPUT Channels : 6 differential, 2 single-ended Input Type : Thermocouple, mv, V, ma Input Range : ±150 mv, ±500 mv, ±1 V, ±5 V, ±10 V, ±20 ma Thermocouple : J, K, T, E, R, S, B Thermocouple Input Range : J -> 0 ~ 760 C K -> 0 ~ 1,000 C T -> 100 ~ 400 C E -> 0 ~ 1,000 C R -> 500 ~ 1,750 C S -> 0 ~ 1,750 C B -> 500 ~ 1,800 C Isolated Voltage : 500 V DC Sampling Rate : 10 samples/sec. Bandwidth : 14 Hz Accuracy : 0.1% Zero Drift : ±6 µv/ C Span Drift : ±25 ppm/ C CMR : 92 db 7-4
5 Intelligent DA&C Modules Analog Input and Digital I/O RTD Input ND-6011 High Gain Analog Input Module ANALOG INPUT Type : mv, V or ma Thermocouple Input Range : J -> -200 ~ +760 C K -> -150 ~ C T -> -200 ~ +400 C E -> -100 ~ C R -> 0 ~ C S -> 0 ~ C B -> 0 ~ C Input Range : ±15 mv, ±50 mv, ±100 mv, ± 500 mv, ±1 V, ±2.5 V, and ±20 ma Sampling Rate : 10 samples/sec Accuracy : ±0.05% or better Zero Drift : ±0.03 µv / C Span Drift : ±25 ppm / C CMR : 50/ db NMR : 50/ db DIGITAL INPUT Channels : 1 (same spec. as ND-6012) DIGITAL OUTPUT Channels : 2 (same spec as ND-6012) ND-6012 Analog Input Module ANALOG INPUT Type : mv, V or ma Input Range : ±150 mv, ±500 mv, ±1 V, ±5 V, ± 10 V and ±20 ma Isolation Voltage : 1600 V RMS (1 min), 2000 V RMS (1 sec) Sampling Rate : 10 samples/sec Bandwidth : 4 Hz Accuracy : ±0.05% or better Zero Drift : ±0.03 µv / C Span Drift : ±25 ppm / C CMR : 50/ db NMR : 50/ db DIGITAL INPUT Channels : 1 Switching Levels : Low (0) -> +1 V Max. High (1) -> +3.5 V ~ +30 V Pull-up Current : 0.5 ma EVENT COUNTER Max Input Frequency : 50 Hz Max. Input Pulse Width : 0.5 msec DIGITAL OUTPUT Channels : 2 Open Collector : to 30 V, 30 ma maximum load ND-6013 RTD Input Module 3-channel ANALOG INPUTS Analog Input Type: -100 or Ni RT RTD type Temperature range -100 ~ +100 C = ~ +100 C = ~ +200 C = ~ +600 C = ~ +100 C = ~ +100 C = ~ +200 C = ~ +600 C = Ni Ni -80 ~ +100 C 0 ~ +100 C Isolation Voltage : 3000 V DC Sampling Rate : 10 samples/sec Bandwidth : 4 Hz Input Wiring : 2, 3 or 4 wires Accuracy : ±0.05% Zero Drift : ±0.3 µv / C Span Drift : ±25 ppm/ C 50/60 Hz : 150 db 50/60 Hz : 100 db 7-5
6 Analog Output Digital I/O Relay Output ND-6021 Analog Output Module ANALOG OUTPUT Voltage Output : 0~10 V Current Output : 0~20 ma, 4~20 ma Output Isolation : 1500 V DC Resolution: 12-bit output Accuracy : ±0.1% of FSR (current) ±0.2% of FSR (voltage) Zero Drift : ±0.2 µa/ C (current) ±30 µv/ C (voltage) Span Drift : ±25 ppm/ C Programmable Output Slope : to 128 ma/sec, to 64 V/sec Bandwidth: 100 samples/sec 7-6 ND-6050 Digital I/O Module Digital Input Channels : 7 Switching Levels : Low (0) -> +1 V Max. High (1) -> +3.5 V ~ +35 V Pull-up Current : 0.5 ma. Digital Output Channels : 8 Open Collector : 30 V, 30 ma max. Power Dissipation : 300 mw Power Consumption : 0.4 W ND-6052 Isolated Digital Input Module Digital Input Channels : 8 6 fully independent isolated and 2 with common ground Switching Levels : Low (0) -> +1 V maximum High (1) -> +3.5 V ~ +30 V Pull-up Current : 0.5 ma Isolated Voltage : 5,000 V RMS Input Resistance : 3K ±0.5 W power Power Consumption : 0.4 W ND-6060 Relay Output Module RELAY OUTPUTS Relay Output Channels : 4 Type : 2 Form C and 2 Form A Contact Rating : AC -> 0.6 A / 125 V, 0.3 A / 250 V DC -> 2 A / 30 V, 0.6 A / 110 V ON/OFF Interval : 3 ms / 1 ms Breakdown Voltage : 500 V Expected Lifetime : 10 8 DIGITAL INPUTS Digital Input Channels : 4 Common External Voltage : +24 V Input Type : source
7 Intelligent DA&C Modules Counter/Frequency Communication Modules ND-6080 ND-6510 ND-6520 Counter/Frequency Input Module COUNTER INPUT Channels : 2 independent 32-bit counters Input Frequency : 50 KHz Max. Input Mode : isolated or non-isolated Isolation Voltage : 2500 V RMS Isolation Input Level : logic level 0 -> +1 V (max) logic level 1 -> 5.3 V~30 V Non-isolated Input Level Programmable Threshold : logic level 0 -> 0~5 V, 0.8 V default logic level 1 -> 0~5 V, 2.4 V default Input Pulse Width : > 10 µsec Max Count : 4,294,967,295 (32-bit) Alarm: alarm comparator on each counter channel Preset Type : absolute or relative RS-485/RS-422 Repeater Input : two wire RS-485 or four wire RS-422 Output : two wire RS-485 or four wire RS-422 Speed : 1200, 2400, 4800, 9600, 19.2K, 38.4K, Kbps Power Consumption : 1 W RS-232 to RS-485/422 Converter Input : RS-232 Output : RS-485/422 Speed : 1200, 2400, 4800, 9600, 19.2K, 38.4K, Kbps Isolation Voltage : 500 V RMS Power Consumption : 1 W UP TO 256 MODULES ON AN RS-485/422 NETWORK Analog Input Thermocouple Input High-gain Analog Input Digital Input Counter/Frequency Input RTD Input FREQUENCY MEASUREMENT Range : 5 Hz ~ 50 KHz Programmable, Build-in Gate Time: 1.0 / 0.1 seconds DIGITAL OUTPUTS Channels : 2 Open collector : 30 V, 30 ma max. Power Dissipation : 300 mw Power Consumption : 0.8 W Analog Output Digital Output RS-485/422 Repeater Relay Output RS-485/422 to RS-232 Converter RS-232 RS-485 RS-422 To host computer 7-7
8 Power Supply Dimensions NDP-243 Panelmount Power Supply Input Voltage : V AC or V AC, switchable Input Frequency : 47~63 Hz Input Current : 1.4 A (max.) Short protection Output Voltage : +24 V DC ±10% Output Current : 3 A (max.) Overload Protection Dimensions : 5" (L) x 3.8" (W) x 1.6" (H) Operating Temperature : 0~50 C 7-8
9 Intelligent DA&C Modules Software and Driver Support REMOTE CONFIGURATION SOFTWARE A Windows based configuration utility is provided to easily configure and calibrate your modules. The utility supports the following functions : - Module scanning - COM port setting - Module configuration - Module calibration - Terminal emulation and Monitoring - Help screens NUDAM'S COMMAND/RESPONSE PROTOCOL There are three categories of commands. General commands --- The first category includes commands that deal with module configuration, identification, initialization. Every modules can respond to these commands. Functional commands --- these commands explicitly refer to a module's specific functions such as digital I/O, analog I/O, counting etc. Modules can only respond to commands that their hardware (and firmware) support. Special commands --- includes control of programmable watchdog timer, safe values and programmable leading codes. The only node in the network that can issue commands is the host computer. When a command has been send the host computer waits for the addressed module to respond. The majority of the commands contain destination address, command identification and data. Responses normally only contain the responding module's address and data. An example how a command/response sequence would look follows below: command : #061<CR> response : > <CR> The command orders an analog input module at address 06 (Hex) to return the value of the input data at channel 1. The module responds with V DLLs work in combination with any Windows programming language that allows DLL calls; such as Visual C/C++ and Visual Basic. DLLs (Dynamic Link Libraries) are an important aspect of Windows. A DLL contains functions that your executable program can call during execution. When your program needs a function that is not in the executable file, Windows loads the dynamic link library (the DLL), making all of its functions available to your application. 's DLL supports Windows 3.1, Windows 95 and Windows NT. NUDAM DDE SERVER To meet the open architecture of several famous Windows NT based MMI/SCADA software packages, modules come with DDE Server support. The Administration I/O DDE (Dynamic Data Exchange) server is a Window-based application program. It takes advantage of DDE, a build-in Windows communications service. This seamless software and hardware integration gives users a comprehensive solution in industrial automation. How to Link with FIX32 and InTouch The DDE server can acquire data from the modules through RS-232 serial ports and passes the data to FIX32 or InTouch via the hot link DDE server. Through the DDE protocol, FIX32 or InTouch can also pass control and configuration commands to the modules. The System Configuration is shown below. Modules RS-232 Ordering DDE SERVER D DE Excel, Database, ODBC... DDE InTouch Fix32 APPLICATION SOFTWARE DEVELOPMENT Because all commands and response are ASCII-based every high-level language (such as C, Pascal or BASIC) can be used to write application software. q ND-DLL6 : Dynamic Link Libraries for Windows 3.1, Windows 95 and Windows NT 4.0 q ND-DDE6 : Dynamic Data Exchange for Windows 3.1, Windows 95 and Windows NT 4.0 DLL Driver 's DLL (dynamic link library) is a Microsoft Windows library module that is linked to your application program at run-time. When linked, the DLL becomes part of your program, giving it additional capabilities and facilities. 7-9
10 InTouch for Process Automation FIX32 is the latest member in the Intellution FIX family of industrial automation software. FIX32 for Windows 95 and Windows NT is the worlds most popular automation solution for MMI and SCADA applications. FIX for Windows 95 and Windows NT is a true 32-bit software application written to Microsoft's Win-32 specification. FIX takes full advantage of all the powerful capabilities of Microsoft's Windows 95 and Window NT operating systems. Wonderware InTouch is an object-oriented, graphical man-machine interface (MMI) application generator for industrial automation, process control and supervisory monitoring. Types of applications include discrete, process, DCS, SCADA and other types of manufacturing environments. It is the fifth generation of the industry's leading MMI from Wonderware. One of the most significant new features, Wonderware's new pre-configured graphic "Wizards," makes the creation of powerful applications faster and easier. Object-Oriented Graphics -- Design impressive screen displays using our intuitive, object-oriented graphical user interface(gui). Real-Time and Historical Trending -- you can collect, store, and display your real-time process data. 100% Data Integrity -- you can always be assured that your process data is totally accurate. Comprehensive Reporting Via DDE -- Produce accurate, customized reports for management and regulatory agencies. Through a two-way DDE interface, you can share your process data with any DDE compatible application. Statistical Process Control (SPC) -- With SPC, you can detect out-of-spec process conditions and make appropriate adjustments before costs are incurred, maximizing product quality, minimizing product waste, and continually improving your processes. Alarming and Alarm Management User-Based Security Recipe Builder Relational Database Support Distributed, Client/Server Architecture Object-Oriented Graphics -- Easy-to-configure applications mean faster development times. Objects and groups of objects can be moved, sized and animated more quickly and simply than bit-mapped graphics. Animation Links -- Animation links may be combined to provide complex size, color, movement, and/or position changes. Animation links include discrete, analog and string touch inputs; horizontal and vertical sliders; discrete and action push buttons; show and hide window push buttons; line, fill and text color links for discrete and analog values and alarms; object height and width links; vertical and horizontal position links; vertical and horizontal percent fill links; visibility links; discrete, analog and string value output links; rotation links and blink links. Wizards -- InTouch includes a library of Wizards -- preconfigured complex objects that users can modify and duplicate freely. Real-time Or Historical Trends -- Built-in objects allow easy creation of real-time and historical trend displays. Display up to eight pens at a time in historical trend charts and have each pen reference a different historical file. 7-10
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationStreamline Your Automation System with M2M Technology
Streamline Your Automation System with M2M Technology Boundless Integration with the ADAM Remote I/O Series In order to meet the integration requirements of Environmental Monitoring Systems and Facility
More informationStraton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech
Straton and Zenon for Advantech ADAM-5550 Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Project Introduction: Programmable Application Controllers (PAC) are powerful and
More informationIntelligent RS-485 I/O expansion unit: RU-87Pn Series
INTRODUCTION RU-87Pn series is a remote intelligent I/O expansion unit that used to expand i-87k series I/O modules over the RS-485 for industrial monitoring and controlling applications. There are more
More informationIsolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationMeasuring Temperature withthermistors a Tutorial David Potter
NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More informationNEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationProgrammable Controller G Series. New. Models
Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control
More informationFLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
More informationDAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationUnidirectional Transmitter/ Receiver Units Introduction
Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created
More informationCPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationEVAL-UFDC-1/UFDC-1M-16
Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1
More informationOptimize your simple machines... Modicon M218 Selection Guide
Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,
More informationM2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit www.advantech.com/products.
M2M I/O Modules 14 M2M I/O Modules Overview 14-2 M2M I/O Modules Selection Guide 14-6 ADAM-2510Z Wireless Router Node 14-8 ADAM-2520Z Wireless Modbus RTU Gateway 14-9 ADAM-2031Z ADAM-2632Z ADAM-2017Z ADAM-2018Z
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationECONseries Low Cost USB DAQ
ECONseries Low Cost USB Data Acquisition Modules ECONseries Low Cost USB DAQ The ECONseries is a flexible yet economical series of multifunction data acquisition modules. You choose the number of analog
More informationEXTERNAL DIMENSIONS AND PARTS
FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationTEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
More informationProcess Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
More information1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
More informationVroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
More informationPD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationNETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationPortal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
More informationWEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationTCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
More informationSubstation Automation Products Relion 670/650 series IEC and ANSI Hardware
Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common
More informationMANUAL FOR RX700 LR and NR
MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical
More informationComputer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE
Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and
More informationEliminate Risk of Contention and Data Corruption in RS-485 Communications
I. Background and Objective Eliminate Risk of Contention and Data Corruption in RS-485 Communications Earle Foster, Jeff Hunter Sealevel Systems The RS-485 communications standard was introduced in 1983
More informationData Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control
More informationTURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES
SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a
More informationSNAP-SCM-PROFI Communication Module
SNAP-SCM-PROFI Communication Module Features Single isolated port with built-in DB-9 connector Baud rates to 1.5 MBaud Works with the SNAP PAC System Up to eight SNAP-SCM-PROFI modules per rack 30-month
More informationM2M/IoT Solutions. www.contec.com
M2M/IoT Solutions www.contec.com M2M/IoT Solutions TM Hardware Highly Reliable M2M Controllers for Various Solutions M2M Controllers Compact design available on DIN rails Low-power design using a CPU tailored
More informationNX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
More informationDigital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
More informationSuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1
SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationT0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
More informationThe software beyond the climatic. Environment simulation
Spirale 2 The software beyond the climatic Environment simulation Spirale 2... Take it easy! Spirale 2 is a new software, based on a reliable system (Windows NT) and if its performances are surprising,
More informationDC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
More informationAllen-Bradley/Rockwell
MANUFACTURER DATA SHEET High Speed Counter Manufacturer: Allen-radley/Rockwell Model Number: 1746-HSCE See www.geomartin.com for additional PDF datasheets Martin Part Number: E-014901-03 VendorPartNumber:
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationIntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
More informationWEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
More informationCPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output
NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages
More informationUSER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
More informationApplication Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
More informationSMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
More informationsigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES
ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS Enhanced defect detection Built-in diagnostics for press machinery Quicker setup and easier maintenance than competitive systems Lowest monitoring cost per
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More informationThe Answer to the 14 Most Frequently Asked Modbus Questions
Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in
More informationLonManager PCC-10 and ISA Protocol Analyzers Models 33100-00 and 33100-10
LonManager and Protocol Analyzers Models 33100-00 and 33100-10 Description The LonManager Protocol Analyzer provides LONWORKS manufacturers, system integrators, and end-users with a rich set of Windows
More informationHigh Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
More information2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
More informationMPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationDS1621 Digital Thermometer and Thermostat
Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationVision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications
Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3
More informationSNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use
SNMP-1000 Intelligent SNMP/HTTP System Manager Features Monitors system fans, temperature, voltage, power supply, CPU fan, CPU temperature, Vcore, watchdog timer etc. Stand alone system monitoring, no
More informationMicro800 Programmable Controllers. Bulletin 2080 Selection Guide
Micro800 Programmable Controllers Bulletin 2080 Selection Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety
More informationIntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
More informationENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000
ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as
More informationManual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
More informationJ TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationOrdering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V
Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input
More informationLINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION
RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction
More informationEZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
More informationWIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
More informationTECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
More informationVibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
More information