1 eberspächer uk automotive systems and instruments wigam air conditioning and refrigeration tooling WIGAM systems AND instruments A world of COMFORT

2 2 automotive systems and instruments centocinquanta 291r evolution is for everybody with hf1234yf and r134a Maximum flexibility to make our units accessible and suitable to everybody s requirements. This machine is compatible with both HF1234YF and R134a. The unit is equipped with two separate recovery circuits which guarantee; a continuous work (in case of failure in one of the circuits, the other keeps working) and the possibility to work in ambient conditions (45 C). technical features Automatic Recovery Automatic Vacuum Automatic Refrigerant Charge Automatic PAG Oil Charge (with scale) Automatic UV PAG Charge (with scale) Automatic POE Oil Charge (with scale) Automatic POE UV Charge (with scale) Automatic Oil Discharge (with scale) Software Flushing (compatible with R134FS4/6) Flushing Software for Universal Flushing Kit Automatic Identification of Leaks (vacuum test) Database can be Updated Printer Automatic Discharge of Non-condensable Gases SAE J2788 / SAE J2843 Selection of the Operation Side (LOW HIGH Both) Recovery Rate Vacuum Pump Swept Volume Bottle Capacity Refrigerant Scale Resolution Oil / UV Scale Resolution Management of Automatic Cycle AZOIDRO Pressure Test Compatible Suitable with Hybrid Vehicles Automatic Lock Scale ALS Dimensions Weight 300 g/min 180 l/min 20 kg 5 g 1 g Optional / Automatic 65 x 55 x 140 cm 110 kg Power Supply 230 / 1 / 50 hose assemblies Hose set for 150 with R134a Hose set for 150 with HF1234YF 291R R

3 automotive systems and instruments 3 AMICA DATA 291R Unit for recovery, recycling, vacuum and charge Automatic recovery / recycling. Automatic vacuum / vacuum test. Automatic oil discharge (with automatic scale). Automatic oil / UV charge (with automatic scale). Automatic refrigerant charge. Automatic personalised cycle ( recovery-vacuum-charge). Flushing cycle. Fully automatic unit. Database that can be updated. New multilingual display. Compressor with High Recovery Performance system that can recover more than 95% of the refrigerant in the A/C system. Quantification of the recovered refrigerant. Printer fitted. Possibility to personalize the print report (5 lines). User programmable with vehicle data. Automatic alarm for service: the unit advises when you have to replace filters and change the vacuum pump oil. Sound signal when the machine has completed the planned operation. 3m Hose Included technical features Universal flushing kit using R134a optional model R134FS R (see page 19) Refrigerant Recovery Rate Pump Swept Volume Bottle Capacity Refrigerant Scale Resolution Oil/UV Scales Resolution R134a 300 g/min 90 l/min 20 kg 5 g 1 g Storage Temperature C Working Ambient Temperature 0 40 C Power Supply 230 / 1 / 50 Connections Dimensions Weight 3/8 SAE 51 x 60 x 111 cm 110 kg

4 4 automotive systems and instruments piccola DATA 291r Unit for recovery, recycling, vacuum and charge The smallest, most compact, fully automatic unit on the market. Automatic recovery / recycling. Automatic vacuum / vacuum test. Automatic oil discharge (with automatic scale). Automatic oil / UV charge (with automatic scale). Automatic refrigerant charge. Automatic personalised cycle ( recovery-vacuum-charge). Flushing cycle. Database that can be updated. New multilingual display. Compressor with High Recovery Performance system that can recover more than 95% of the refrigerant in the A/C system. Quantification of the recovered refrigerant. Printer fitted. Possibility to personalize the print report (5 lines). User programmable with vehicle data. Automatic alarm for service: the unit advises when you have to replace filters and change the vacuum pump oil. Sound signal when the machine has completed the planned operation. technical features Universal flushing kit using R134a optional model R134FS R (see page 19) Refrigerant Recovery Rate Pump Swept Volume Bottle Capacity Refrigerant Scale Resolution Oil/UV Scales Resolution R134a 300 g/min 90 l/min 10 kg 5 g 1 g Storage Temperature C Working Ambient Temperature 0 45 C Power Supply 230 / 1 / 50 Connections Dimensions Weight 3/8 SAE 50 x 40 x 90 cm 50 kg

5 automotive systems and instruments 5 AMICA bus 291r Unit for recovery, recycling, vacuum and charge Designed and realised for the maintenance of big dimension A/C systems Ideal for public and private transports such as buses, trains, trucks, etc. The unit is equipped with two separate recovery circuits which guarantee; A recovery rate of 800 g/min. The possibility to work in unfavourable ambient conditions (45 C). A continuous work (in case of failure in one of the circuits, the other keeps working). On request available for R404A / R407C. Fully automatic unit. Large backlit LCD and multilingual display. One key for each function. 4 electronic scales (Refrigerant Oil discharge Oil charge UV additive charge). Distillation system with automatic control. Integrated flushing function. FIRE & GO function. Thermal printer with option of multiple print. Database on extractable Smart Card (can also be updated manually by the operator). Data interface with PC by means of Smart Card. Integrated temperature probe. Integrated pressure gauge for reading of pressure inside the bottle. Universal flushing kit using R134a optional model R134FS R (see page 19) technical features Refrigerant Recovery Rate Pump Swept Volume Bottle Capacity Refrigerant Scale Resolution Oil/UV Scales Resolution R134a 800 g/min 180 l/min 40 kg 5 g 1 g Storage Temperature C Working Ambient Temperature 0 40 C Power Supply 230 / 1 / 50 Connections Dimensions Weight 3/8 SAE 51 x 60 x 111 cm 160 kg

6 6 automotive systems and instruments fox evo range Not Only a Digital Manifold: A TRUE WORKSTATION 4 way digital manifold EVO Benefits High Precision Built-in Electronic Vacuum Gauge (0 900 Pa). Scale, Capacity kg, Resolution 2 g. Integrated Data Logger. Micro SD Card Included. Micro SD Reader Included. 230V 50 / 60 Hz Feeder Included. System s Test Under Pressure. Max operating pressure 56 bar. Accuracy better than 1% FS. More than 50 refrigerants (including 1234YF, R134a, R407C). Possibility to update with new gases. Type K temperature probes. 4-way piston manifold. Sight glass. High quality ceramic pressure sensor (Range bar). 230V 50 / 60 Hz feeder included. Possibility to use all K probes. Scale up to 100 kg, resolution 2 g. Torr micron inhg mtorr mbar Pa Included Micro SD card and reader for data transfer. Integrated data logger. Built-in electronic vacuum gauge. uac torr

7 automotive systems and instruments 7 fox 500 evo 291R way digital manifold EVO Benefits High Precision Built-in Electronic Vacuum Gauge (0 900 Pa). Scale, Capacity kg, Resolution 2 g. Integrated Data Logger. Micro SD Card Included. Micro SD Reader Included. 230V 50 / 60 Hz Feeder Included. System s Test Under Pressure. Max operating pressure 56 bar. Accuracy better than 1% FS. More than 50 refrigerants (including 1234YF, R134a, R407C). Possibility to update with new gases. Type K temperature probes. 4-way piston manifold. Sight glass. High quality ceramic pressure sensor (Range bar). Kit complete with: Digital manifold in plastic case with 2 TK109 probes. 1 flexible hose V/WSS/4-4/60. 1 flexible hose WSS/4-4/60. 2 flexible hoses WSA/4-4/60. 2 quick couplers W-AV134. Model FOX-500-EVO Dimensions 310 x 370 x 130mm Weight 3.2 kg Packs 1 or 8

8 8 automotive systems and instruments fox 500 evo with scales 291R way digital manifold EVO Benefits High Precision Built-in Electronic Vacuum Gauge (0 900 Pa). Scale, Capacity kg, Resolution 2 g. Integrated Data Logger. Micro SD Card Included. Micro SD Reader Included. 230V 50 / 60 Hz Feeder Included. System s Test Under Pressure. Max operating pressure 56 bar. Accuracy better than 1% FS. More than 50 refrigerants (including 1234YF, R134a, R407C). Possibility to update with new gases. Type K temperature probes. 4-way piston manifold. Sight glass. High quality ceramic pressure sensor (Range bar). Kit complete with: Digital manifold in plastic case with 2 TK109 probes. 1 electronic scale kg. 1 flexible hose V/WSS/4-4/60. 1 flexible hose WSS/4-4/60. 2 flexible hoses WSA/4-4/60. 2 quick couplers W-AV134. Model FOX-500-EVO / SCALE Dimensions 325 x 460 x 132mm Weight 5.9 kg Packs 1 or 4

9 automotive systems and instruments 9 fox 500 evo accessories electronic scales 291r Electronic scale kg, resolution 2 g for FOX EVO. universal temperature probe 291r fast reacting temperature probe 291r

10 10 automotive systems and instruments way manifold kit Sturdy plastic case containing: 1 x 4 way manifold. 3 flexible hoses 1,800mm. 1 flexible hose 1,800mm. 2 quick couplers.

11 automotive systems and instruments 11 manifold accessories gy flexible hoses Hoses 1,800mm suitable for charging station and manifold sets. Hoses can be supplied in different colours: blue, red and yellow. quick couplers for 134a 291R / 291R technical features In Accordance With SAE J2196/R134a-UL1963 Model Description W-AV134/B4/6 Blue Knob LP coupler 1/4 SAE M with adapter 1/4 SAE F x 3/8 SAE M Working Pressure Bursting Pressure 5.6 MPa 28 MPa Working Temperature C 291r / 291R R / 291R Model Description W-AV134/R4/6 Red Knob HP coupler 1/4 SAE M with adapter 1/4 SAE F x 3/8 SAE M 4 way manifold 291r R Blue 291R Yellow 291R Red 291R Yellow 3/8 carry case 291r Model Description W4MS80/A6/4/K1 R22-R134a-R404A-R407C Refrigerants 3 x 1/4 SAE + 1 x 3/8 SAE Model Description VP 370 x 290 x 100mm

12 12 automotive systems and instruments RECOVERY UNIT 291r double stage high vacuum pump 291r Able to work with all CFC, HCFC and HFC refrigerants. Created to work especially with R410A. Self-evacuation system which allows you to change the type of refrigerant easily. Automatic stop of the unit when there is no refrigerant available in the system (this device can be switched on or off). Visual signal (green LED) when recovery is completed. Automatic safety shut-off of the unit in case of high pressure (38.5 bar) with visual alarm (red LED). Equipped with a dry compressor. Equipped with a filter drier and humidity glass. Equipped with a high capacity ventilation system. Extremely silent. technical features Model DIP 402 Swept Volume 90 l/min Ultimate Vacuum 1 x 10-2 mbar Power Supply (other supplies on request) / 1 / Nominal Power 240 W Protection Degree IP54 Oil Charge 300 cc Dimensions 285 x 150 x 260mm Weight 10 kg Model Dimension Weight EASYREC x 250 x 350mm 17 kg MANIFOLD VACUUM GAUGE 291r Model Description W1VPF80/4 Wigam 1-way manifold vacuum gauge, with safety valve and hook. 1/4 SAE x 1/4 SAE

13 automotive systems and instruments 13 discovery explorer 291R uv lamps 291R heated sensor electronic leak detector Detects ALL halogenated refrigerants. These include, but are not limited to: CFC: R12-R11-R500-R503 ecc. HCFC: R22-R123-R124-R502 ecc. HFC: R134a-R404a-R125-R407C-R507-R410A ecc. Kit complete with: Lamp Injection gun. Single-dose dye cartridges (6 off). Adapter hose R134. Adapter 1/4. UV enhancing glasses. technical features Sensitivity Sensor Life Response Time Power Supply Batteries Life Warm-up Time Probe Length Numeric Leak Side Indicator 1.5 g/year 0.05 oz/yr 300 hours Instantaneous 4 AA Alkaline batteries 8 hours continuous <20 seconds 43 cm 7 segment digital display (1 to 9)

14 14 automotive systems and instruments pratika scales 291r heater with thermostat 291r Programmable and electronic scale up to 100 kg. Maximum Weight Capacity: 100 kg. Resolution: 5 gr. Accuracy: 0.5%. Units: kg or lbs/oz. Power Supply: 9V alkaline battery. Operating Temperature: 0 C to 45 C. Auto off function. Dimensions: 380 x 300 x 80mm. Weight: 3.1 kg. Dimensions: 700 x 80mm. The heater is supplied with two springs. adapter 291r /4 SAE 2 adapters for Freon cylinders with gasket.

15 automotive systems and instruments 15 HEAVY DUTY NITROGEN REGULATOR 291r valve core removal tool 291r Model AZ200-50/E Model CTV 1 Description Nitrogen regulator with UK connections. Description Core screwer tool Inlet Pressure 20 MPa Working Pressure MPa Connection 1/4 SAE spray leak detector 291r Model Quantity GAS CONTROL 10 x 400 ml

16 16 automotive systems and instruments total test a/c Complete kit for leak detection 291r TOTAL TEST-A/C is a new kit that enables to detect and locate leaks in the A/C system in compliance with Directive 2006/40/EC The pressure reducer and the control pressure gauge in class 1 enable to pressurise the system to the necessary value with the AZOIDRO mixture; the system can then be checked by means of the specific leak detector, FINDER. The TOTAL TEST A/C kit includes: Pressure regulator 4.8 MPa (48 bar). Control gauge Ø80, class 1 with positioning indicator. 1 x Heavy Duty flexible hose 1/4 SAE, 1,500mm. 2 x quick couplers 1/4 SAE. AZOIDRO cartridge. FINDER electronic leak detector. Sturdy plastic carrying case. DIRECTIVE 2006/40/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 17 May 2006 relating to emissions from air conditioning systems in motor vehicles and amending Council Directive 70/156/EEC. Article 6 - Retrofitting and refilling 3. Service providers offering service and repair for air conditioning systems shall not fill such equipment with fluorinated greenhouse gases if an abnormal amount of the refrigerant has leaked from the system, until the necessary repair has been completed. azoidro 291r Disposable 1 litre bottle containing 95% Nitrogen and 5% Hydrogen, which allows you to pressurise the system and then to find the leak source by means of the specific FINDER leak detector.

17 automotive systems and instruments 17 thermometry accessories digital dual input thermometer 291r The TFC-502 is a very reliable digital thermometer with dual input, particularly used by technicians to measure temperature in two different zones in the cooling system. Features CE mark approval. Dual digital display. MAX / MIN with elapsed time, AVG, REL, HOLD, RECORD functions. Warning beeper with High / Low setting. Dual input function. In accordance to temperature standard ITS-90. C / F user-selective, Time setting, REL setting. Resolution: 0.1. Technical Features Display: 4 digit liquid crystal display (LCD) with a maximum reading of Polarity: Automatic, positive implied, negative polarity indication. Zero: Automatic. Low battery indication. Measurement Rate: One time per second. Operating Environment: 0 C to 50 C at <70% of relative humidity. fast reacting temperature probe 291r Temperature Range: -200 C ~ 800 C; -328 F ~ 1,472 F. Accuracy: C ± (0.5% rdg + 2 dgts) F ± (0.5% rdg + 4 dgts). Model Dimensions Weight TFC x 92 x 53mm 250 g universal temperature probe 291r

18 18 automotive systems and instruments hose crimping air hydraulic pump 291r Fixed to a sturdy and elegant metal frame, the APT100 air-hydraulic pump is a powerful unit that allows draw out of a hydraulic flow in pressure from a pneumatic supply. equipped with Pedal unit usable either on the bench or on earth. Silencer in order to reach an acceptable level of noise pollution. Quick type hydraulic fitting. Protection cap. manual hydraulic crimping set 291r Lightweight, compact, reliable and inimitable. Crimping modular system especially designed and made to answer needs of professional technicians for crimping HVAC hoses of conditioning and refrigeration systems. Dies for tubes: Internal 2mm diameter x external 5.9mm diameter. Internal 4mm diameter x external 8.2mm diameter. Internal 6mm diameter x external 10.9mm diameter. Technical specifications Pneumatic Supply: System air or nitrogen. Supply Pressure: From 5 to 8 bar. Pneumatic Inlet: 1/4. Noise: 70 / 80 dba at 1m. Maximum Working Pressure: 600 bar. Safety Valve: Pre-set and externally sealed. Hydraulic Outlet: 1/4 quick type adjustable. Oil Reservoir Capacity: 1,400 cc. Durable, precise and controlled pump. The crimper will crimp aluminium and steel fittings reliably, uniformly and on top of it all, we now offer a way to check the accuracy. The diameter of the resulting crimp can be checked, using the special caliper provided with the crimper. The basic set includes; hydraulic pump, manual crimper, set of 3 dies, lubricant and caliper. Model Dimensions Weight APT x 300 x 180mm 10 kg adaptor hose set 291r

19 automotive systems and instruments 19 flush systems FLUSH&DRY 291r Flush&Dry is the new Wigam flushing station that solves all the problems concerning the flushing and fluxing of A/C and HVAC systems, even of big dimensions. Professionals in the sector agree that flushing with a fluid is the only solution that allows to: Remove all solid residues caused by the breakage of the compressor or of the filter. Remove completely the residues of oil from the HVAC and A/C systems. Pump Flow Rate Pump Maximum Pressure Nitrogen Regulator Output Pressure Pump Motor Power Power Supply Dimensions Weight 14 l/min 0.45 MPa 0.50 MPa 0.6 kw / 1 / Hz 300 x 220 x 550mm 14 kg properties Flushing of circuit that have a bigger volume than the 10 standard litres of the container. Fluxing of the system by means of the nitrose regulator and nitrogen cartridge BN2/1-950cc. Pre-set connection for extra container. Connection for external nitrogen bottle. External valves and synoptic label for easy operations. Pump equipped with mechanical seal and PTFE gaskets. A mechanical filter on the suction side. Flexible hoses with: Interchangeable connections of 1/4 SAE, 3/8 SAE and 1/2 SAE for HVAC. Universal cones for A/C (automotive). universal flushing kit 291R Universal Flushing Kit Allows the flushing of A/C systems using R134a. Can be directly interfaced with all recovery stations manuals or automatic. INSPECTOR cylinder to check the refrigerant quality after the flushing. Possibility to disconnect the INSPECTOR from the kit so that one can use it separately by means of the hoses supplied.

20 20 automotive systems and instruments flash flush Flushing System 1. Connect the flexible hose (end with valve) to the bottle. Quick and Cheap. 4 Easy Operations. Flushing and Fluxing. Ready for use with flushing fluid pressurized with nitrogen, it enables you to perform the system s flushing and its following fluxing in 4 easy operations. The FLASH-FLUSH system, with 1/4 SAE connections, contains 800 g of SUPER-FLUSH pressurized with nitrogen at 30 bar. 2. Turn the bottle upside down. FLASH-FLUSH must be completed with a connecting kit KIT-FLASH-A/C. The KIT-FLASH-A/C includes: 1 flexible hose, 900mm model V/WSS4-4/36. 1 universal cone and clamp. 3. Connect the other end of the hose to the system. 4. Open the valve of the flexible hose to perform the flushing (SUPER FLUSH fluid) and the fluxing (NITROGEN) of the system.

21 automotive systems and instruments 21 flush system and accessories flash-flush BOTTLE 291r cool cleaner 291r x FLASH-FLUSH flushing system. Innovative non-flammable and azeotropic mixture of solvents (replaces R11 and R141B). Studied for the flushing of refrigeration, civil and automotive air conditioning (A/C) systems. Can be used with pressure systems (A/CF-P-H) and systems equipped with pump (FLUSH&DRY). flash-kit NOT INCLUDING BOTTLE 291r FLASH-KIT-A/C Connecting kit for A/C system. super flush 291r SUPER-FLUSH is the new fluid for the inside flushing of A/C and HVAC systems. It is compatible with metals usually used in A/C and HVAC systems and with most plastic material. Strong cleaning action. Easy to remove (fast evaporation). Can be used with pressure systems (A/CF-P-H) and systems equipped with pump (FLUSH&DRY). cartuccia 291r cc bottle. To be used with flushing fluids COOL-CLEANER and SUPER-FLUSH.

22 22 automotive systems and instruments leak stop a/c 291R Stop leak system for A/C systems LEAK STOP is the new stop leak for A/C systems. The easy and fast solution to seal with just one application all the leaks that are difficult to detect and reach with conventional tools. Leak-Stop system is based on the use of a sealing fluid that reacts in the presence of leaks as it comes into contact with both refrigerant and oxygen. Does not crystallize. Usable with all refrigerants. Compatible with 100% of the systems on the market. Complete compatibility with gaskets and seals of the system. The maximum size of the leak that can be sealed is 708 g/year (in 24 hours). The fluid can seal leaks that are subsequent to the date of the intervention on the system (6 12 months). The fluid must be introduced into the system only from the low pressure side with the system in vacuum or with the system charged, but with an internal pressure lower than 13 bar. The kit includes: 1 injection system. 1 pre-charge cartridge (7.5 ml). 2 LEAK-STOP cartridges (30 ml). 1 flexible hose with LP quick coupler. 1 LP adapter. leak stop cartridge 291r

23 automotive systems and instruments 23 mini UV KIT system 291R Kit complete with: Injection gun. Single-dose dye cartridges (6 off). Adapter hose R134. Adapter 1/4. dye cartridges 291r

24 The comprehensive Eberspächer product range also includes HEATING, AIR CONDITIONING and refrigeration SYSTEMS FOR COMMERCIAL VEHICLES, CARS, BUSES, COACHES, MOTORHOMES, CARAVANS, MARINE, OFF-HIGHWAY AND MILITARY APPLICATIONS. More information is available from one of our 5,000 service partners worldwide. AUTHORISED DEALER Eberspächer (UK) Ltd Climate House Yeoman Road, Ringwood Hampshire BH24 3FA Tel: Fax: D Issue B 01/2015 Printed in UK. Subject to change without notice.

Tools & Equipment Robinair

Tools & Equipment Robinair Tools & Accessories 2 Robinair Product overview AC RAnge Robinair is VDA and TüV approved and carries SAE-J approval. Robinair is approved by the following OEM s: 3 Robinair Moving from R134a to R1234yf

More information

Car and commercial cial air conditioning service solutions

Car and commercial cial air conditioning service solutions Car and commercial cial air conditioning service solutions THE STANDARD IN INFORMATION AND DIAGNOSTICS SYSTEMS INTRODUCTION For the KoolKare range of vehicle air conditioning service equipment we went

More information

Product overview Air conditioning service units

Product overview Air conditioning service units Product overview Air conditioning service units 02 03 AIR CONDITIONING SERVICE UNITS FROM ROBINAIR ARE THE WORLD S MOST ADVANCED AND MOST POPULAR AIR CONDITIONING SERVICE UNITS FOR CARS; TRUCKS AND BUSSES.

More information

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS

KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS KOOLKARE CAR & COMMERCIAL AIR CONDITIONING SERVICE SOLUTIONS THE STANDARD IN INFORMATION, EQUIPMENT AND DIAGNOSTICS SYSTEMS h t t p : / / d i a g n o s t i c s. s n a p o n. c o. u k KOOLKARE INTRODUCTION

More information

AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany

AC Service Equipment ACE 21 EXPERT. Fully automatic service station. R-1234yf refrigerant. Made in Germany AC Service Equipment ACE 21 EXPERT Fully automatic service station R-1234yf refrigerant Made in Germany The new generation of air conditioning service equipment: Robust. Environment-friendly. Fully automatic.

More information

Measurement Solutions for Refrigeration Technology.

Measurement Solutions for Refrigeration Technology. Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. Testo refrigeration technology Digital is better: Refrigeration technology expertise

More information

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop ACS 600, 601, 650: Air conditioning service units from Bosch u ACS 600 even the entry model is fully automatic u ACS

More information

Automotive Air-Conditioning Service Equipment Ariazone 5001 OPERATOR MANUAL Ariazone 5001

Automotive Air-Conditioning Service Equipment Ariazone 5001 OPERATOR MANUAL Ariazone 5001 Automotive Air-Conditioning Service Equipment Ariazone 5001 OPERATOR MANUAL Ariazone 5001 - Automotive A/C Service Station 1 Contents Page 1. Introduction... 3 2. Safety firts... 4 3. Technical Features...

More information

Excellence for Professionals: Air Conditioning Service with Bosch ACS 752, 652, 611, 511, 810 and 661

Excellence for Professionals: Air Conditioning Service with Bosch ACS 752, 652, 611, 511, 810 and 661 Excellence for Professionals: Air Conditioning Service with Bosch ACS 752, 652, 611, 511, 810 and 661 1 A/C service from Bosch Air conditioning systems in vehicles require regular maintenance. The market

More information

Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651

Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651 Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651 ACS 751 and 651 A/C service unit from Bosch for R134a u ACS 751 fully automatic: Air conditioning system service for cars

More information

Guide to good leak testing

Guide to good leak testing Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant

More information

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop Prüftechnik ACS 600, 601, 650 Air conditioning service units from Bosch NEW! Ñ ACS 600 even the entry model is fully

More information

Non solo un gruppo digitale: UNA VERA STAZIONE DI LAVORO! Not only a digital manifold: A TRUE WORK-STATION! NEW FOX EVO. Torr mtorr micron inhg

Non solo un gruppo digitale: UNA VERA STAZIONE DI LAVORO! Not only a digital manifold: A TRUE WORK-STATION! NEW FOX EVO. Torr mtorr micron inhg FOX EVO 62 Gruppo manometrico digitale a vie VANTAGGI EVO VACUOMETRO ELETTRONICO DI ALTA PRESSIONE INTEGRATO (0 900 Pa) BILANCIA, CAPACITÀ 0 100 KG, RISOLUZIONE 2G DATA LOGGER INTEGRATO MICRO SD CARD INCLUSA

More information

Air Conditioning Service Tools & Equipment

Air Conditioning Service Tools & Equipment 27/04/12 G2 R-410A Service Manifold & Gauges (BlackMax ) Exclusive TripleSeal valve system Valve stems retract fully for maximum flow Back seating o-ring seals valve nut when fully open Aluminum block

More information

Precision for Professionals: Air Conditioner Service with Bosch ACS 751, 651 and 551

Precision for Professionals: Air Conditioner Service with Bosch ACS 751, 651 and 551 Precision for Professionals: Air Conditioner Service with Bosch ACS 751, 651 and 551 ACS 751, 651 and 551 A/C service unit from Bosch for R134a u ACS 751 fully automatic: Air-conditioning system service

More information

Excellence for Professionals: Air Conditioner Service with Bosch ACS 752, 652, 611, 511, 810 and 661

Excellence for Professionals: Air Conditioner Service with Bosch ACS 752, 652, 611, 511, 810 and 661 Excellence for Professionals: Air Conditioner Service with Bosch ACS 752, 652, 611, 511, 810 and 661 1 A/C service from Bosch Air conditioning systems in vehicles require regular maintenance. The market

More information

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale

More information

Flushing and Cleaning the A/C System

Flushing and Cleaning the A/C System Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING

More information

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507 Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not advocate the wholesale changeover of HCFCs

More information

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants

More information

Elements Elements describe the essential outcomes.

Elements Elements describe the essential outcomes. AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes

More information

Subject: 2005 Air Conditioning Service Guidelines

Subject: 2005 Air Conditioning Service Guidelines Date: June 27, 2005 Bulletin Number: 05D-J-114 To: DDG Headquarters and Branches and Jobbers Category: Service From: Steve Sigg, Product Service and Training Line(s): 10 and 15 Subject: 2005 Air Conditioning

More information

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system AURETU004 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system 2. Diagnose air conditioning and

More information

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...

More information

AUTOMOTIVE AIR CONDITIONING

AUTOMOTIVE AIR CONDITIONING 3rd Edition 3rd Edition Resources available For the instructor Register online at: www.cengagebrain.com for the study tools that come with your textbook! Companion website: includes weblinks and downloadable

More information

MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE

MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE Faculty are required to have the outline submitted to the Academic Affairs Office. The course outline is the form used for approval of new courses

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont

More information

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

A/C refrigerant system, overview

A/C refrigerant system, overview Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

Model ATD-36750 Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

Model ATD-36750 Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends Model ATD-36750 Refrigerant Gas Leak Detector Detects all CFC, HFC, HCFC, HFO Refrigerants including blends User Manual Design certified by ASCI and Intertek to meet SAE J2791, J2913 & EN14624 INTRODUCTION

More information

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as

More information

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION) Form #SB4-304AS AirSourceR SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION) Second only to refrigerant hose leaks, compressors have the highest rate

More information

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction

More information

ThermoStar Refrigeration Air Dryers

ThermoStar Refrigeration Air Dryers ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems

More information

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by

More information

Information on New Refrigerant (R-1234yf) for A/C Service

Information on New Refrigerant (R-1234yf) for A/C Service Information on New Refrigerant (R-1234yf) for A/C Service 2013 Cadillac ATS, XTS This bulletin is being revised to include procurement and labeling information for recovery cylinders to be used with GE-50957-Contaminated

More information

ENGINE COOLING SYSTEM

ENGINE COOLING SYSTEM ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,

More information

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Recharge Procedure for Telemark TVP-2000 and TVP-3500 Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Druck PV 62x pneumatic/hydraulic pressure stations

Druck PV 62x pneumatic/hydraulic pressure stations GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300

More information

MACHINES FOR REFRIGERATION AND AIR CONDITIONING

MACHINES FOR REFRIGERATION AND AIR CONDITIONING 00 MA0900 MACHINES FOR REFRIGERATION AND AIR CONDITIONING The widespread use of air conditioning systems, both civil and industrial, in order to increase the comfort at work and at home, as well as the

More information

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 2 Date : - 24/01/12 UNPACKING Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands

More information

Air conditioning service unit CAAS500

Air conditioning service unit CAAS500 Air conditioning service unit CAAS500 OPERATING INSTRUCTIONS TES1453 09/2004 C A A S 5 0 0 O P E R A T I N G I N S T R U C T I O N S P a g e 2 IMPORTANT THIS MANUAL CONTAINS INFORMATION PERTINENT TO OPERATOR

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test APTA STANDARDS DEVELOPMENT PROGRAM RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA BTS-BMT-RP-001-10 Approved October, 2010 APTA Bus Maintenance

More information

Table of Contents. First Aid for Refrigerant Exposure 35. First Aid for Skin Exposure / First Aid for Eye. Chapter 3:

Table of Contents. First Aid for Refrigerant Exposure 35. First Aid for Skin Exposure / First Aid for Eye. Chapter 3: Table of Contents Chapter 1: Introduction to Automotive Heating, Air Conditioning, and Ventilation 11 Heating, Ventilating, and Air Conditioning (HVAC) Systems 12 Why Is It Called HVAC? Major Heating,

More information

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8). DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

Hybrid Air Conditioning Systems Overview

Hybrid Air Conditioning Systems Overview Southern Illinois University Carbondale OpenSIUC Presentations Department of Automotive Technology Spring 2011 Hybrid Air Conditioning Systems Overview Eugene Talley Southern Illinois University Carbondale,

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

RS-24 (R426A): Q & A

RS-24 (R426A): Q & A RS-24 (R426A): Q & A 1 Q: What is RS-24? A: RS-24 is a non ozone depleting Drop-in replacement for R12 in all applications including mobile air conditioning. 2 Q: Yes, but what does RS-24 contain? A: RS-24

More information

53403500 - Injector Max Machine

53403500 - Injector Max Machine 53403500 - Injector Max Machine Operating Instructions Contents Page Introduction Operating Instructions Fuel Injection Cleaner - Petrol Operating Instructions Fuel Injection Cleaner - Diesel 3 Operating

More information

How To Use An Irius Pid Detector

How To Use An Irius Pid Detector SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning S Y L L A B U S Your Course Learning Plan UAWLETC EK 4-13-06 A. General Course Information Course description: The Heating and Air Conditioning students of UAW-LETC will successfully

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

More information

MIDLAND COLLEGE SYLLABUS DEMR 1323 AUTOMOTIVE HEATING AND AIR CONDITIONING 2-4

MIDLAND COLLEGE SYLLABUS DEMR 1323 AUTOMOTIVE HEATING AND AIR CONDITIONING 2-4 Course Description: Text, References and Supplies: Course Goals/Objectives: Theory of automotive air conditioning and heating systems. Emphasis on the basic refrigeration cycle and diagnosis and repair

More information

Fire suppression system for engine compartments USER MANUAL

Fire suppression system for engine compartments USER MANUAL Fire suppression system for engine compartments USER MANUAL Contractor s machinery/vehicles, tooling machines and special machines Edition 2011-3 Hydro pneumatic activation Mechanical activation Electrical

More information

Designed for multi-injector endurance testing, the

Designed for multi-injector endurance testing, the Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016. Information compiled by Frank Prah, CMS

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016. Information compiled by Frank Prah, CMS Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois 60016 REFRIGERANT 410A Information compiled by Frank Prah, CMS INTRODUCTION Recently a new refrigerant, R-410A, has been formulated

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

Waste Oil Handling, Spill Containment & Lighting

Waste Oil Handling, Spill Containment & Lighting 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20

More information

RS-44 (R424A) : Q & A

RS-44 (R424A) : Q & A RS-44 (R424A) : Q & A 1 Q: What is RS-44? A: RS-44 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-44 contain? A: RS-44 is a blend of HFC134a, HFC125,

More information

This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series

This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for AR512 series and SAE J2099 and J2210 for AR500 series MOBILE REFRIGERANT RECOVERY/RECYCLING SYSTEM MODELS AR500 AR512 SERIES TO BE OPERATED BY QUALIFIED PERSONNEL ONLY! This equipment has been certified by ITS/ETL to meet or excees SAE J1990 and J1991 for

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Basic Hydraulics and Pneumatics

Basic Hydraulics and Pneumatics Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:

More information

Refrigeration Air Dryers ADQ. Capacity: 21-4200 m 3 /h

Refrigeration Air Dryers ADQ. Capacity: 21-4200 m 3 /h Refrigeration Air Dryers Capacity: 21-4200 m 3 /h Water Contamination in Compressed Air T he w a t er c o n t a i n e d i n a c o m p r e s s e d a i r s y s t e m w i l l va r y acc o r d i n g t o a

More information

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C GUIDELINES FOR UTILIZATION OF R407C 2009 Tecumseh Products Company. All rights reserved. Page 1 of 6 After many years of testing and investigation, R407C is recognized as a suitable alternative refrigerant

More information

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

UNITOR VACUUM cleaners

UNITOR VACUUM cleaners UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Structure of this presentation

Structure of this presentation Michael Matthias Structure of this presentation The copying, distribution and utilization of this document as well as the communication of its contents to others without expressed authorization is prohibited.

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

Screw Compressors 11-22kW

Screw Compressors 11-22kW INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature

More information

Accumulators and Receivers

Accumulators and Receivers aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

Operations and Maintenance Manual

Operations and Maintenance Manual Operations and Maintenance Manual FOR MODELS 1234XL 1090XL 1095XL P/N 99971-SP Rev. 1/98 Table of Contents Set-Up...1 Introduction... 1 Unit Set-Up... 1 White Industries Models...1 1090XL Panel and 1234XL

More information

Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details!

Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details! Compact Air Solutions C Series 2.2 7.5 kw Screw Compressors Want a 5. year warranty? Ask for details! Air. CompressedAir. BogeAir. Now you can! CM compact module 2.2 7.5 kw Effective free air delivery:

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Rotary Screw Compressor. MSM MINI 2,2-3 - 4-5,5 kw

Rotary Screw Compressor. MSM MINI 2,2-3 - 4-5,5 kw Rotary Screw Compressor MSM MINI 2,2 3 4 5,5 kw EN The MSM Mini Range MINI 2,2 3 4 5,5 kw A solution to satisfy all needs Base Mounted Version Especially recommended for installations near the place of

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de

LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Refrigerated Air Dryers. Catalogue

Refrigerated Air Dryers. Catalogue Refrigerated Air Dryers Catalogue GB Why use a refrigerated dryer? Humidity is a component of atmospheric air, which can be found in the compressed air distribution systems and the machines that use the

More information