1 Filter Fans High performance and fast mounting Modern design A positive visual impact is given by the up-to-date design of the grills and the minimal external projection. All moulded parts are made of highly resistant and self-extinguishing ABS, UL94 VO grade. The standard coior is RAL RAL 7032 is also available. On request and for substantial quantities, non standard colors are also available. Fast installation Installation is fast thanks to the simple square cut-out on the enclosure panel and to the snap-in fixing system. No screws are needed. The snap-in fixing system can be used on panels with thickness in the range mm. For different thickness, fixing can still be done with the screw kit included in each pack for this purpose. Wide range of air flow ratings The range of air flow ratings goes from 24 to 630 m3/h. For all filter fans, default air flow direction is from the outside towards the inside of the enclosure. If needed the user can easily reverse the direction by simply re-assembling the fan in the opposite way (only on specified models). No interference outside the enclosure 5 mm is the maximum projection outside the enclosure. This means no problems during transportation and enclosure operational life, typical instead of the bigger and cumbersome traditional units. High reliability Alfa Electric only uses the best quality ball bearing fans. They ensure a high efficiency and have an expected life of working hours at an ambient temperature of 55 C. They are all designed to ensure a quick and safe electrical connection. Optimal enclosure protection The special configuration of the grill, the self-adhesive gasket and the filter mat ensure an IP54 protection degree towards the enclosure. Power supply Alfa Electric filter fans are available in the following AC supply voltages: 230V single-phase, 5V single-phase and 400V three-phase, all bi-frequency Hz. In addition, 24 and 48VDC versions are available up to 230 m3/h. On request they can also be available with other rated voltages not shown in this catalogue. Filter units To achieve optimal cooling air circulation, filter fans are used together with filter units. Filter units are available in four different sizes and have the same design of the external part of a filter fan. Cooling performance diagram Cooling capacity (W) Temperature difference (K) Example: Waste heat to be removed 500W Temperature difference 20K Air flow required 78m3/hr Filter fan unit solution: n. ALFA2300BPB + n. ALFA2000BPB When selecting a Filter Fan unit, always keep a margin of at least l0% to compensate for any air flow decay due to filter mat clogging. Air flow rate (m³/hr) 9

2 Filter fans 24 m 3 /hr ALFAA5 Features Unit ALFAA000BPB ALFAA500BPB ALFAA50BPB ALFAA52BPB ALFAA524BPB Air flow rate (free blow) m³/h - 24(28) 24 Flow rate with exit filter m³/h - 4(7) 4 Power supply V/Hz - 230/ / DC 24DC Dimensions HxWxD mm 4x4x7 4x4x57 4x4x45 Power consumption W - 3(2) 3 4 Current consumption A - 0.0(0.08) 0.4(0.2) Overcurrent protection - - impedance Electric connection - - faston 2.8x0.5 mm 2-pole terminal.5 mm² Duty cycle % Operating temperature C - -0/+70 Protection degree/class - IP54 IP54/Class I Noise level db(a) - 30(35) 35 Flow direction - - outside-in Filter mat (Eurovent) - EU2 Material - ABS UL94V-0 Color RAL7035 Wall thickness mm Gasket - self-adhesive Weight (with packaging) kg 0.06(0.0) 0.38(0.43) 0.8(0.23) Package dimensions mm 20x20x20 20x20x60 Mounting - Fast Clip-on UL ALFAA000BPUB ALFAA500BPUB ALFAA50BPUB ALFAA52BPUB ALFAA524BPUB RAL Gray - Code ending RAL Black - Code ending, add N (available on request) EMC - Code ending M Reverse flow - Code ending - PR Connection with terminals - K - Filter mat, standard type ALFAFBP00 Filter mat, high efficiency ALFAFBP00X Thermostat 0-60 C, NO contact - THV2 Power cord m - SPINOTTOA2-0 - Fan speed controller - FSC Hood for IP55 CUFF0B TIP If possible it is better to use the units with the air flow from the outside to the enclosure inside. The slight pressurization of the panel prevents dust from getting through any openings. 0

3 Filter fans 55 m 3 /hr ALFA5 - ALFA6 Features Unit ALFA000BPB ALFA600BPB ALFA60BPB ALFA524BPTB ALFA548BPTB Air flow rate (free blow) m³/h - 55(60) 55 Flow rate with exit filter m³/h - 40(45) 40 Power supply V/Hz - 230/ / DC 48DC Dimensions HxWxD mm 50x50x28 50x50x77 Power consumption W - 22(2) 9 3 Current consumption A - 0.4(0.2) 0.26(0.24) Overcurrent protection - - impedance Electric connection - - faston 2.8x0.5 mm 2-pole terminal.5 mm² Duty cycle % Operating temperature C - -0/+70 Protection degree/class - IP54 IP54/Class I Noise level db(a) - 43(49) 45 Flow direction - - outside-in Filter mat (Eurovent) - EU3 Material - ABS UL94V-0 Color RAL7035 Wall thickness mm Gasket - self-adhesive Weight (with packaging) kg 0.6(0.2) 0.78(0.85) 0.47(0.54) Package dimensions mm 65x65x45 65x65x85 Mounting - Fast Clip-on UL ALFA000BPUB ALFA600BPUB ALFA60BPUB ALFA524BPTUB ALFA548BPTUB RAL Gray - Code ending RAL Black - Code ending, add N (available on request) EMC - Code ending M Reverse flow - Code ending - PR Connection with terminals - K - Filter mat, standard type ALFAFBP0 Filter mat, high efficiency ALFAFBP0X Thermostat 0-60 C, NO contact - THV2 Power cord m - SPINOTTOA2-0 - Fan speed controller FSC Hood for IP55 CUFF0B TIP If you are using the high filtering capacity filter mat remember that air flow rate will decrease.

4 Filter fans 0 m 3 /hr ALFAB5 Features Unit ALFAB000BPB ALFAB500BPB ALFAB50BPB ALFAB524BPTB ALFAB548BPTB Air flow rate (free blow) m³/h - 0(20) 0 Flow rate with exit filter m³/h - 80(92) 80 Power supply V/Hz - 230/ / DC 48DC Dimensions HxWxD mm 204x204x30 204x204x98 Power consumption W - 22(2) 9 3 Current consumption A - 0.4(0.2) 0.26(0.24) Overcurrent protection - - impedance Electric connection - - faston 2.8x0.5 mm 2-pole terminal.5 mm² Duty cycle % Operating temperature C - -0/+70 Protection degree/class - IP54 IP54/Class I Noise level db(a) - 43(49) 45 Flow direction - - outside-in Filter mat (Eurovent) - EU3 Material - ABS UL94V-0 Color RAL7035 Wall thickness mm Gasket - self-adhesive Weight (with packaging) kg 0.26(0.36).00(.20) 0.70(0.90) Package dimensions mm 220x220x40 220x220x0 Mounting - Fast Clip-on UL ALFAB000BPUB ALFAB500BPUB ALFAB50BPUB ALFAB524BPTUB ALFAB548BPTUB RAL Gray - Code ending RAL Black - Code ending, add N (available on request) EMC - Code ending M Reverse flow - Code ending - PR Connection with terminals - K - Filter mat, standard type ALFAFBPB0 Filter mat, high efficiency ALFAFBPB0X Thermostat 0-60 C, NO contact - THV2 Power cord m - SPINOTTOA2-0 - Fan speed controller FSC Hood for IP55 CUFF20B TIP The filter fan unit can be switched on by a thermostat that will power it only when the temperature exceeds a set threshold (e.g. 35 C). The fan works only when cooling is needed which saves energy, increases the lifetime of the filter mat and reduce maintenance frequency. 2

5 Filter fans 20 m 3 /hr ALFA23 Features Unit ALFA2000BPB ALFA2300BPB ALFA230BPB ALFA2324BPTB ALFA2348BPTB Air flow rate (free blow) m³/h - 20(30) 20 Flow rate with exit filter m³/h - 00(0) 00 Power supply V/Hz - 230/ / DC 48DC Dimensions HxWxD mm 250x250x30 250x250x Power consumption W - 22(2) 9 3 Current consumption A - 0.4(0.2) 0.26(0.24) Overcurrent protection - - impedance Electric connection - - faston 2.8x0.5 mm 2-pole terminal.5 mm² Duty cycle % Operating temperature C - -0/+70 Protection degree/class - IP54 IP54/Class I Noise level db(a) - 43(49) 45 Flow direction - - outside-in Filter mat (Eurovent) - EU3 Material - ABS UL94V-0 Color RAL7035 Wall thickness mm Gasket - self-adhesive Weight (with packaging) kg 0.42(0.52).20(.40) 0.90(.0) Package dimensions mm 270x270x40 270x270x40 Mounting - Fast Clip-on UL ALFA2000BPUB ALFA2300BPUB ALFA230BPUB ALFA2324BPTUB ALFA2348BPTUB RAL Gray - Code ending RAL Black - Code ending, add N (available on request) EMC - Code ending M Reverse flow - Code ending - PR Connection with terminals - K - Filter mat, standard type ALFAFBP20 Filter mat, high efficiency ALFAFBP20X Thermostat 0-60 C, NO contact - THV2 Power cord m - SPINOTTOA2-0 - Fan speed controller FSC Hood for IP55 CUFF20B TIP DC powered filter fan units can be the best way to prevent EMC interference to monitors and other sensitive equipment inside the enclosure. 3

6 Filter fans m 3 /hr ALFA25 - ALFA26 Features Unit ALFA2000BPB ALFA2500BPB ALFA250BPB ALFA2524BPTB ALFA2548BPTB ALFA2600BPB ALFA260BPB ALFA2640BPB Air flow rate (free blow) m³/h - 230(260) (400) Flow rate with exit filter m³/h - 80(20) (270) Power supply V/Hz - 230/ / DC 48DC 230/ / /50-60 Dimensions HxWxD mm 250x250x30 250x250x9 250x250x0 Power consumption W - 40(38) (90) 60(70) Current consumption A - 0.7(0.6) 0.34(0.32) (0.38) 0.80(0.76) 0.8(0.5) Overcurrent protection - - thermal impedance thermal Electric connection pole terminal 2.5 mm² 4-pole terminal.5 mm² Duty cycle % Operating temperature C - -0/+70 Protection degree/class - IP54 IP54/Class I Noise level db(a) - 53(58) 6 65(68) Flow direction - - outside-in Filter mat (Eurovent) - EU3 Material - ABS UL94V-0 Color RAL7035 Wall thickness mm Gasket - self-adhesive Weight (with packaging) kg 0.42(0.52).60(.80).20(.40) 2.50(2.70) Package dimensions mm 270x270x40 270x270x40 Mounting - Fast Clip-on UL ALFA2000BPUB ALFA2500BPUB ALFA250BPUB ALFA2524BPTUB ALFA2548BPTUB ALFA2600BPUB ALFA260BPUB - RAL Gray - Code ending RAL Black - Code ending, add N (available on request) EMC - Code ending M Reverse flow - Code ending - PR Filter mat, standard type ALFAFBP20 Filter mat, high efficiency ALFAFBP20X Thermostat 0-60 C, NO contact - THV2 Fan speed controller - FSC Hood for IP55 CUFF20B ALFA25 ALFA26 4

7 Filter fans m 3 /hr ALFA35 - ALFA36 Features Unit ALFA3000BPB ALFA3500BPB ALFA350BPB ALFA3540BPB ALFA3600BPB ALFA360BPB Air flow rate (free blow) m³/h - 500(570) 630(700) Flow rate with exit filter m³/h - 370(40) 470(520) Power supply V/Hz - 230/ / / / /50-60 Dimensions HxWxD mm 325x325x30 325x325x5 Power consumption W - 70(90) 60(70) 30(80) Current consumption A (0.38) 0.80(0.76) 0.8(0.5) 0.55(0.8).0(.62) Overcurrent protection - - thermal Electric connection pole terminal 2.5 mm² 4-pole terminal.5 mm² Duty cycle % Operating temperature C - -0/+70 Protection degree/class - IP54 IP54/Class I Noise level db(a) - 65(68) 72(73) Flow direction - - outside-in Filter mat (Eurovent) - EU3 Material - ABS UL94V-0 Color RAL7035 Wall thickness mm Gasket - self-adhesive Weight (with packaging) kg 0.64(0.78) 3.00(3.25) 3.65(3.90) Package dimensions mm 340x340x45 340x340x75 Mounting - Fast Clip-on UL ALFA3000BPUB ALFA3500BPUB ALFA350BPUB - ALFA3600BPUB - RAL Gray - Code ending RAL Black - Code ending, add N (available on request) EMC - Code ending M Reverse flow - Code ending - PR Filter mat, standard type ALFAFBP30 Filter mat, high efficiency ALFAFBP30X Thermostat 0-60 C, NO contact - THV2 Fan speed controller - FSC Hood for IP55 CUFF30B ALFA35 ALFA36 5

8 Filter fans high-thickness ALFA 000 series ALFA 2000 series ALFA 3000 series Model Description Voltage (V) Frequency (Hz) Power (W) Absorbed current (A) Noise level db (A) Filter fan air volume free blowing m³/h Filter fan air volume with exit filter **m³/h ALFA 000 AP Filter 30x30 ALFA 524 APT Filter fan 30x30 24 DC ALFA 548 APT Filter fan 30x30 48 DC ALFA 600 AP Filter fan 30x /60 9/8 0.4/0.2 46/50 55/60 40/45 ALFA 60 AP Filter fan 30x /60 9/8 0.25/0.9 46/50 55/60 40/45 ALFA 2000 AP Filter 256x256 ALFA 2324 APT Filter fan 256x DC ALFA 2348 APT Filter fan 256x256 48DC ALFA 2400 AP Filter fan 256x /60 9/8 0.4/0.2 47/53 20/30 95/05 ALFA 240 AP Filter fan 256x /60 9/8 0.25/.09 47/53 20/30 95/05 ALFA 2500 AP Filter fan 256x /60 40/ / /58 230/260 75/200 ALFA 250 AP Filter fan 256x /60 40/ / /58 230/260 75/200 ALFA 2524 APT Filter fan 256x DC ALFA 2548 APT Filter fan 256x DC ALFA 3000 AP Filter 325x325 ALFA 3500 AP Filter fan 325x /60 70/ / /68 480/ /380 ALFA 350 AP Filter fan 325x /60 70/ / /68 480/ /380 ALFA 3540 AP Filter fan 325x /60 60/70 0.8/0.5 65/68 500/ /380 **Jointed an exit filter of equal dimension TECHNICAL FEATURES: products comply with directives 73/23/EEC and 89/336/EEC; ball bearing axial fans marked CE (some models available with UL and CSA approval); plastic material self-extinguish ABS V0 RAL 7032/7035 black on request; high efficiency dust filters made of self-extinguish acrilic fibre; protection degree IP

9 Roof fans m 3 /hr ALFATORR ROOF FAN AND VENT Features Unit ALFATORRB ALFATORR0600B ALFATORR060B ALFATORR0860B ALFATORR086B ALFATORR000B ALFATORR00B Air flow rate (free blow) m³/h - 600(625) 860(950),000(,050) Flow rate with inlet filter m³/h - 430(450) 580(640) 700(720) Power supply V/Hz - 230/ / / / / /50-60 Dimensions HxWxD mm 400x350x02 400x350x02 Power consumption W - 70(90) 85(5) 20(70) Current consumption A (0.40) 0.64(0.80) 0.43(0.50) 0.86(.00) 0.50(0.75).00(.50) Overcurrent protection - - thermal Electric connection pole terminal 2.5 mm² Duty cycle % Operating temperature C - -0/+70 Protection degree enclosure side - IP44 Protection class - - Class I Noise level db(a) - 64(65) 72(73) Flow direction - - inside-out Material - ABS UL94V-0 Color RAL7035 Gasket - Polythene Weight (with packaging) kg 2.30(2.50) 3.65(3.85) 4.00(4.20) 4.75(4.95) Package dimensions mm 40x360x30 Mounting - Screws UL ALFATORRUB ALFATORR0600UB ALFATORR060UB ALFATORR0860UB ALFATORR086UB - RAL7032 -Gray - Code ending EMC - Code ending M - IP54 - Code ending F Thermostat 0-60 C, NO contact - THV2 Grill with filter mat ALFA3000BPB Fan speed controller - FSC Spare filter mat ALFAFT0 7

10 Roof fans m 3 /hr ALFATORR4 ROOF FANS Features Unit ALFATORRMETB ALFATORR450B ALFATORR45B Air flow rate (free blow) m³/h - 500/(550) Flow rate with filter fan m³/h - 900/(950) Power supply V/Hz / /60 Dimensions HxWxD mm 540x390x28 540x390x28 Power consumption W - 60/(25) Current consumption A /(0.98).40/(.96) Overcurrent protection - - thermal Electric connection pole terminal Duty cycle % Operating temperature C - -20/+50 Protection degree enclosure side/class - - IP44/Class I Noise level db(a) - 74/(75) Flow direction - - inside-out Material - metal RAL7035 Gasket - PVC PVC Weight (with packaging) kg 5.2(5.5).3(2.3) Package dimensions mm 550x400x40 550x400x40 Mounting - Screws Screws RAL Gray - Code ending IP54 - Code ending F Thermostat 0-60 C, NO contact Grill with filter mat Fan speed controller Spare filter mat THV2 ALFA3000BPB FSC ALFAFT5 8

11 Fan trays m 3 /hr RACK FAN TRAYS FOR 9 ENCLOSURES Features Unit RACK0222 RACK022 RACK0224 RACK0248 RACK0322 RACK032 RACK0324 RACK0348 Air flow rate (free blow) m³/h 300(360) (540) 450 Power supply V/Hz 230/ / DC 48DC 230/ / DC 48DC Dimensions HxWxD mm 482x44x208 Power consumption W 36(34) (5) Current consumption A 0.26(0.22) 0.48(0.36) (0.33) 0.72(.08) Overcurrent protection - impedance Electric connection - 3-pole terminal 2.5 mm² Duty cycle - 00% Operating temperature C -0/+70 Protection degree/class - IP30/Class I Noise level db(a) 5(52) Flow direction - bottom to top Bearing - ball Service life (at 40 C) hr 50,000 Material - PC-ABS UL94V-0 Color RAL7035 Weight (with packaging) kg 2.0(2.30).60(.80) 2.60(2.80).85(2.05) Package dimensions mm 50x220x65 Mounting - Screws Thermostat 0-60 C, NO contact Fan speed controller THV2 FSC 9

12 Fans m 3 /hr AC/DC FANS AC Fans Code m³/hr Bearing Power supply V/Hz Connection Dim. mm. V08BT230VAC 60 ball /50-60 fast-on 9x9x38 V08BT5VAC 60 ball 0-20/50-60 fast-on 9x9x38 V08BT24VAC 60 ball 24/50-60 fast-on 9x9x38 V08BT48VAC 60 ball 48/50-60 fast-on 9x9x38 V08ST230VAC 60 sleeve /50-60 fast-on 9x9x38 V08ST5VAC 60 sleeve 0-20/50-60 fast-on 9x9x38 V08ST24VAC 60 sleeve 24/50-60 fast-on 9x9x38 V08ST48VAC 60 sleeve 48/50-60 fast-on 9x9x38 V087BT230VAC 90 ball /50-60 fast-on 27x27x38 V087BT5VAC 90 ball 0-20/50-60 fast-on 27x27x38 V08XBT230VAC 05 ball /50-60 fast-on 20x20x25 V08XBT5VAC 05 ball 0-20/50-60 fast-on 20x20x25 V08JCSW230VA 65 sleeve /50-60 wires 92x92x38 V08JCSW5VA 65 sleeve 0-20/50-60 wires 92x92x38 V08JCBT230VA 65 ball /50-60 fast-on 92x92x38 V08JCBT5VA 65 ball 0-20/50-60 fast-on 92x92x38 V08BBT230VAC 50 ball /50-60 fast-on 92x92x25 V08BBT5VAC 50 ball 0-20/50-60 fast-on 92x92x25 V08BST230VAC 50 sleeve /50-60 fast-on 92x92x25 V08BST5VAC 50 sleeve 0-20/50-60 fast-on 92x92x25 V08ABT230VAC 45 ball /50-60 fast-on 80x80x38 V08ABW230VAC 45 ball /50-60 wires 80x80x38 V08ABT5VAC 45 ball 0-20/50-60 fast-on 80x80x38 V08AST230VAC 45 sleeve /50-60 fast-on 80x80x38 V08AST5VAC 45 sleeve 0-20/50-60 fast-on 80x80x38 V08AXBT230VA 35 ball /50-60 fast-on 80x80x25 V08AXBW230VA 35 ball /50-60 wires 80x80x25 V08AXBT5VA 35 ball 0-20/50-60 fast-on 80x80x25 V08AXST230VA 35 sleeve /50-60 fast-on 80x80x25 V08AXST5VA 35 sleeve 0-20/50-60 fast-on 80x80x25 V08EXBT230VA 325 ball /50-60 fast-on 72x50x5 V08EXBW230VA 325 ball /50-60 wires 72x50x5 V08EXBT5VA 325 sleeve 0-20/50-60 fast-on 72x50x5 V08EXBW5VA 325 ball 0-20/50-60 wires 72x50x5 V08EXST230VA 325 sleeve /50-60 fast-on 72x50x5 V08EXST5VA 325 ball 0-20/50-60 fast-on 72x50x5 V08EXMBT230V 340 ball /50-60 fast-on 72x50x38 V08EXMBT5V 340 ball 0-20/50-60 fast-on 72x50x38 V08CBW230VA 350 ball /50-60 wires 62x50x55 V08CBW5VA 350 ball 0-20/50-60 wires 62x50x55 V08KBW230VAC 600 ball /50 wires 220x60 V08KBW5VAC 600 ball 0-20/50 wires 220x60 V08HHBT230VA 800 ball /50-60 fast-on 254x89 V08HHBT5VA 800 ball 0-20/50-60 fast-on 254x89 DC Fans Code m³/hr Bearing Power supply V/Hz Connection Dim. mm. V08EXBW24VDC 460 ball 24 DC wires 72x50x5 V08EXBW48VDC 460 ball 48 DC wires 72x50x5 V087BW24VDC 240 ball 24 DC wires 27x27x38 V087BW48VDC 240 ball 48 DC wires 27x27x38 V08BW2VDC 80 ball 2 DC wires 9x9x38 V08BW24VDC 80 ball 24 DC wires 9x9x38 V08BW48VDC 80 ball 48 DC wires 9x9x38 V08SW2VDC 80 sleeve 2 DC wires 9x9x38 V08SW24VDC 80 sleeve 24 DC wires 9x9x38 V08SW48VDC 80 sleeve 48 DC wires 9x9x38 V08MBW2VDC 50 ball 2 DC wires 20x20x25 V08MBW24VDC 50 ball 24 DC wires 20x20x25 V08MSW2VDC 50 sleeve 2 DC wires 20x20x25 V08MSW24VDC 50 sleeve 24 DC wires 20x20x25 V08BBW24VDC 00 ball 24 DC wires 92x92x25 V08DBW2VDC 65 ball 2 DC wires 80x80x25 V08DBW24VDC 65 ball 24 DC wires 80x80x25 V08DSW2VDC 65 sleeve 2 DC wires 80x80x25 V08DSW24VDC 65 sleeve 24 DC wires 80x80x25 V08FSW24VDC 35 sleeve 24 DC wires 60x60x25 V08GBW24VDC 5 ball 24 DC wires 40x40x20 Other articles available on demand 20

13 VENTILATION COMPACT FILTER UNITS Suitable for direct screw mounting on axial fans. They can also be mounted with the fan inside the enclousure. The mounting holes have diameter Ø mm. The material is black ABS, self-estinguishing, according to UL94 V-O. Code ALFAKF060 ALFAKF080 ALFAKF092 ALFAKF20 ALFAKF50 ALFAKR20 Dim. mm. Pcs in pack 60x60 80x80 92x92 20x20 50x50 COMPACT FILTER UNITS - HIGH PERFORMANCE Compact filter unit with reduced pressure drop. Filter media, steel or acrilic, is easy accessible and cleaneable. Available in three versions: Code Description Compact filter unit w/ standard filter mat Dim. mm. Pcs in pack 25x25x0 20 ALFAKR20R Compact filter unit w/metallic filter mesh 25x25x0 20 ALFAKR20RF Compact filter unit w/standard 25x25x0 filter mat and metallic filter mesh 20 ALFAKR20 SPINOTTO Description Compact filter unit Compact filter unit Compact filter unit Compact filter unit Compact filter unit FAN POWER CORDS Suitable to all fast-on connection fans. Black cable with injection moulded straight plug for 2,8x0,5 mm pins. Code Description SPINOTTOA2-06 Straight power cord 600 mm. SPINOTTOA2-0 Straight power cord 000 mm. SPINOTTOA2-20 Straight power cord 2000 mm. Pcs in pack ael-cat-en Specifications, values and drawings are subject to change without notice. ALFAKF Ventilation accessories 2

14 Ventilation accessories ALFAF ALFAFBPx0 - Spare filter mats for filter fans Standard filter mats for ALFAxxxxBPB filter fans and filter only units. To keep high performance it is necessary to periodically check the level of filter mat clogging and, if necessary, replace it with a new one. These filters are made of self-extinguishing synthetic fibres with a progressive filtering capacity. Code Description Pcs in pack ALFAFBPA0 Filter mat for ALFAA000BPB 0 ALFAFBP0 Filter mat for ALFA000BPB 0 ALFAFBPB0 Filter mat for ALFAB000BPB 0 ALFAFBP20 Filter mat for ALFA2000BPB 0 ALFAFBP30 Filter mat for ALFA3000BPB 0 ALFAFBPx0X - High efficiency spare filter mats for filter fans High efficiency filter mats are used in is very fine dust environments. However, air flow rates is substantially reduced and should be accounted for when selecting the filter fan. Code Description Pcs in pack ALFAFBPA0X Filter mat for ALFAA000BPB, high efficiency 0 ALFAFBP0X Filter mat for ALFA000BPB, high efficiency 0 ALFAFBPB0X Filter mat for ALFAB000BPB, high efficiency 0 ALFAFBP20X Filter mat for ALFA2000BPB, high efficiency 0 ALFAFBP30X Filter mat for ALFA3000BPB, high efficiency 0 ALFAFTx Code Description Pcs in pack ALFAFT0 Filter mat for ALFATORR0600B-00B 5 ALFAFT5 Filter mat for ALFATORR450B-45B 5 GRV90/GRV250 GRV90/GRV250 Grilled shroud for radial fans. They allow safe operation and increased air flow rate on radial fans. Features Unit GRV90 GRV250 a mm b mm c mm d mm 3 5 e mm ALFAGM METALLIC PROTECTION GRILLS Finger guard metallic protecion grills for axial fans. Range Ø mm. Complying with international safety norms. Code Description Dim. mm. Pcs in pack ALFAGM040 Metallic finger protection grill Ø ALFAGM060 Metallic finger protection grill Ø ALFAGM080 Metallic finger protection grill Ø ALFAGM092 Metallic finger protection grill Ø ALFAGM20 Metallic finger protection grill Ø ALFAGM27 Metallic finger protection grill Ø ALFAGM50 Metallic finger protection grill Ø ALFAGM220 Metallic finger protection grill Ø ALFAGM254 Metallic finger protection grill Ø

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000 Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),

More information

Rittal TopTherm fan-and-filter unit

Rittal TopTherm fan-and-filter unit Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Fresh Air Enclosure Cooling Filter Fans

Fresh Air Enclosure Cooling Filter Fans 763.576.3200 SPEC-00306 K763.422.2211 COOLING FRESH AIR ENCLOSURE COOLING FILTER FANS Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient! Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black

USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-

More information

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series SILENT-1 Series Range of axial extractors with airflow rates of 85 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

19 Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted. 19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile

More information

How To Drive A Compact Serie 1

How To Drive A Compact Serie 1 Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR

More information

Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580

Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580 Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

Energy Communication Unit (ECU)

Energy Communication Unit (ECU) Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...

More information

Manual. Solar Fountain Mobile Phone Charger

Manual. Solar Fountain Mobile Phone Charger EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

TFSR & TFSK Roof Fans

TFSR & TFSK Roof Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof

More information

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

SERVICE SERVICE COMPACT MANUAL. Mod. 3000 92X Mod. 3000 93X Mod. 3000 94X. Part 2

SERVICE SERVICE COMPACT MANUAL. Mod. 3000 92X Mod. 3000 93X Mod. 3000 94X. Part 2 SERVICE COMPACT SERVICE 000 MANUAL Mod. 000 9X Mod. 000 9X Mod. 000 94X Part Forward This Service Handbook is intended to assist with servicing and fault-finding in Caravans and Motor Caravans equipped

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Energy Communication Unit (ECU)

Energy Communication Unit (ECU) Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

BITMAIN. APW3-12-1600 PSU Series User Guide

BITMAIN. APW3-12-1600 PSU Series User Guide BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand 9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Mitel DECT Base Stations

Mitel DECT Base Stations Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

CutMaster 82. 6.04 Major External Replacement Parts

CutMaster 82. 6.04 Major External Replacement Parts CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080

More information

Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com

Installation Guide. DEVIreg 530. Electronic Thermostat. www.devi.com Installation Guide DEVIreg 530 Electronic Thermostat www.devi.com The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48 Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

I Notification. Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO

I Notification. Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO I Notification Loudspeaker HONEYWELL COMMERCIAL VOICE ALARM AUDIO Honeywell is a Fortune 100 company that invents and manufactures technologies to address tough challenges linked to global macro trends

More information

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Life Expectancy : Class A Class B Class C Class D 30,000hrs 10,000hrs 3,000hrs 1000hrs

Life Expectancy : Class A Class B Class C Class D 30,000hrs 10,000hrs 3,000hrs 1000hrs 3.2 Motor Run Capacitors : continuous operation ypical Applications : Motor Run Capacitor ideal for various motor applications in washing machine, air conditioner, electric water pump, power factor collection

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

HP 2530 8-Port Switches Quick Setup Guide

HP 2530 8-Port Switches Quick Setup Guide HP 2530 8-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and information to

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850 victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850 SECTIONS ENGLISH 1 NEDERLANDS 27 DEUTSCH 55 This page intentionally left blank. ENGLISH USER MANUAL Victron Atlas

More information

Knürr Smaract. Knürr Smaract. CompactRack

Knürr Smaract. Knürr Smaract. CompactRack CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy. Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

7000 Series Buccaneer

7000 Series Buccaneer The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently

More information