Veterinary Imaging Past, Present and Future- Digital Radiography

Size: px
Start display at page:

Download "Veterinary Imaging Past, Present and Future- Digital Radiography"

Transcription

1 Veterinary Imaging Past, Present and Future- Digital Radiography ROBERT H. WRIGLEY Professor Veterinary Diagnostic Imaging University of Sydney Veterinary Teaching Hospital Professor Emeritus Colorado State University Colostate Uni Typical X-ray machine 1950s Colostate Uni Restriction of X-ray field Collimation X-Ray machine with slide in lead diaphragms 1

2 Light (projection) beam diaphragm with adjustable Lead Shutters X-RAY MACHINES Portable max output 20mA, 80KV 50 ma 100KV High Frequency X-RAY MACHINES Ceiling mounted, 2000mA 150KV Automatic Film Processors 1960s Dry, Processed Film in 90 seconds Underdevelopment From under replenishment per film From developer oxidization in too large a storage tank Courtesy Konica 2

3 Photographic film in cassette RARE EARTH SCREEN-FILM SINGLE EMULSION FILM SINGLE FINE SCREEN INCREASED DETAIL INCREASED EXPOSURE INCREASED RADIOGRAPHIC CONTRAST Computerised X-ray machine operating controls at the X-ray tube Courtesy of SEDECAL USA Inc. Radiology in the 20 th Century Diagnostic Imaging in the 21 st Century 3

4 Digital Radiography Film Radiography Digital Radiography Film Radiography X-Ray Capture Device Conversion to DICOM computer file Display on Workstation Monitor Film Darkroom Film Processing Light Box Image optimization software Computer file/folder PACS Computer database/archive Electronic delivery Paper envelope File shelves Hand/mail delivery Digital Imaging & Communications in Medicine Picture Archive & Communication Systems ADVANTAGES Image Auto correction of Image Whiteness This feature is available on some Systems -Simplifies X-ray Technique setting -If not a feature vendor must provide an accurate technique chart and patients measured and exposed as you would for film. Latitude allows for some manual correction of mild over or under exposure Film/Screen 80 KVp 44mAs DR Image processed with automatic correction selected 80 KVp 44mAs Film/Screen 60 KVp 16mAs Advantages of Filmless Digital Imaging Versus Film Radiography Gray Scale Latitude DR Image processed with automatic correction selected 60 KVp 16mAs Film Digital 4

5 Gray Scale Processing Non-linear Gray scale transformation using stored settings (Algorithms) optimized for anatomical region imaged Detail Enhancement Especially useful to improve visualization of bone + lung detail Unsharp mask filtering Customized for object size + level of enhancement Unsharp Mask Filtering Can create black lines along radiolucent structures such as metallic implants Artifact halation, over-shoot, uberschwinger ADVANTAGES Eliminate darkroom and film processing Potential for patient side image viewing ADVANTAGES Can use computer graphic software to optimize image brightness & contrast. Whiten mildly overexposed images Darken mildly underexposed images Cost saving as eliminates - Film - Processing supplies - Darkroom - Film jackets & Files Electronic distribution of images via Networks For diagnosis For consultation/second opinions Input into an electronic medical record 5

6 DISADVANTAGES Need to be a skilled computer user Need computer support personnel All systems more expensive than film/screen cassettes and an automatic processor Image detail less than good quality radiographs X-Ray exposure level effects Image detail Exposure settings - those appropriate for > 400 speed FS and faster result in suboptimal CR image detail - Exposure settings as used for 300 speed FS and higher exposures are optimal for CR imaging - Newer systems using double sided plates and other plate halides now allow exposure to be significantly reduced. Courtesy Fuji Medical Syst. Automatic Image correction Some systems provide feed back information on the radiation level to the patient. Fuji Sensitivity S# = equivalent FS exposure level S# 110 AGFA LGM Exposure Index # Optimal X-Ray Exposure = X Recommended Exp = 2.4 ½ Recommended Exp =1.9 Digital Image Rectangular matrix of differing colored squares (Pixels=Picture Elements) What has been the effect on resolution of bony detail? S# P Detail Resolution dependent on: Pixel size proportional to total number and size of pixels -- physical size/quality of computer monitor -- quality of computer video card 2000 Pixels 64 Pixels 8 0 P I Acquiston Device Film/screen (all sizes) Digital Radiology Detectors 5 x 7.5cm 22 x 27cm 35 x 43cm Resolution Matrix # of Pixels Crystals Diodes Transistors Dental 2,256x2878 2,208x2688 Pixel size Microscoptic 30 um um um 2 Spacial Resolution Line Pairs/mm 5-15 Lp/mm ~ 15 Lp/mm ~ 5 Lp/mm ~ 3 Lp/mm I X X E E L L S S 6

7 Film/screen (all sizes) Crystals Microscoptic 5-15 Lp/mm Film/screen (all sizes) Crystals Microscoptic 5-15 Lp/mm Digital Radiology Detectors 5 x 7.5cm 22 x 27cm 35 x 43cm Diodes Transistors Dental 2,256x2878 2,208x um um um 2 ~ 15 Lp/mm ~ 5 Lp/mm ~ 3 Lp/mm Digital Radiology Detectors 5 x 7.5cm 22 x 27cm 35 x 43cm Diodes Transistors Dental 2,256x2878 2,208x um um um 2 ~ 15 Lp/mm ~ 5 Lp/mm ~ 3 Lp/mm Courtesy Eklin Film/screen (all sizes) Digital Radiology Detectors 5 x 7.5cm 22 x 27cm 35 x 43cm Crystals Diodes Transistors Dental 2,256x2878 2,208x2688 Microscoptic 30 um um um Lp/mm ~ 15 Lp/mm ~ 5 Lp/mm ~ 3 Lp/mm American College of Radiology Teleradiology Display Monitor Standard (1999) Real size display of human chest = 35 x 43cm film ~monitor 53cm diagonal size Resolution not < 2.5 lead lines per mm > 2000K x 2500 pixels (5 Mega Pixels) Courtesy Eklin Monochrome BW Medical DICOM factory calibrated LCD Monitors 2 Mega Pixels 5 M Pix 3 M Pix 1600 x 1200 ACR display standard DR detector Computer Monitors Consumer Level High End Medical-US,CT Radiographic ( not ACR std) Resolution Size 35 x 43cm 35 x 43cm 22 x 27cm Variable 53cm diagonal 35 x 43cm Zoom x 2 Then Pan Pixel Matrix 2000x mega pixel 2,208x2688 2,256x x x Mega Pixel 2000x x x

8 Pan to view remainder of the magnified image Contrast Resolution dependent on: Brightness of monitor Number of colors per pixel (bits) Grey scale images (Radiographic images, grey scale is 1/3 rd of total number of colors) Dependent on -- quality of video card (number of colors) -- quality of computer monitor 10 bits (1,024) 8 bits (256) Brightness of Light Boxes Monochrome BW Medical DICOM factory calibrated LCD Monitors 2 Mega Pixels 1600 x M Pix 5 M Pix 8

9 Liquid Crystal Display LCD Grayscale Monitors Now preferred as brighter and more stable than TV type monitors Monitor Display Test Pattern 1022 Gray tones $4-15,000 32cm x 43cm Black/White DICOM Calibrated Gray Scale High Brightness (>600 cd/mm 2 ) 10 bit video card Self calibrating Courtesy of Computed Radiography (CR=DR) generates digital radiographic images (computer files) from scanning a reusable radiation sensitive imaging plate Film CR SPATIAL RESOLUTION 6 pixels/mm (for 35 x 43cm ) 8 pixels/mm (for 24 x 30cm) 10 pixels/mm (for 18 x 24cm) Courtesy of IDEXX Labs. Inc 9

10 Reading the Imaging Plate Rotating Prism Imaging Plate Light Guide PM Tube Laser Translation Acquisition Device Film/Screen CR Plate 35x43cm 24x30cm Matrix (Pixels) Microscopic Crystals Microscopic Crystals 3520x x x x2370 Resolution Pixels Adjustable by laser beam 10/mm 5/mm 15/mm 10/mm Spatial Resolution Line Pairs/mm 5-15 Lp/mm ~5 Lp/mm ~2.5Lp/mm ~7 Lp/mm ~5 Lp/mm CR SCANNERS Melbourne and Camden Uni Vet Hospital Fuji CAPSULA Courtesy of IDEXX Labs. Inc Courtesy Agfa HealthCare Courtesy of IDEXX Labs. Inc 10

11 Anatomic specific Image Processing Loading Cassette Courtesy of IDEXX Labs. Inc Courtesy of IDEXX Labs. Inc CR Specific Image Artifacts Scattered Radiation Unloading Cassette Courtesy of IDEXX Labs. Inc CR Plate Moiré Patterns The term originates from moiré in its French form, a type of textile, traditionally of silk but now also of other fibers, creating a rippled appearance. Effect of turning grid line sets 2 sets of parallel lines inclined at an angle 5 degrees to one another Superposition of 2 similar patterns rotated by an angle α Courtesy of: 11

12 CR image made with a stationary grid 110 lines per inch. What is the image quality artifact? Moire problem How to stop this? -Use a Bucky -Turn the grid lines right angle to scan axis -Replace with a grid recommended by CR vendor, lines per inch EXPENSIVE * FOGGING BY SCATTERED X-RAYS & BACKGROUND RADIATION Erasing Plates Dirt on plate or in scanner will create white artifacts CR Plates and the Scanner need to be cleaned regularly Plus Image mottle from too low an X-ray exposure Courtesy of IDEXX Labs. Inc Non Automated system Clipping of the thinnest densities of the lungs from over exposure Original Beyond the range of manual correction ORGINAL Clipping of the thickest densities of the spine Beyond the range of manual correction 12

13 ELECTRONIC PLATE X-RAY DETECTORS SMALL AREA DENTAL RADIOGRAPHY DR FILM LESS Dental Digital Radiography Using Charge Coupled Device CCD (light detector in digital cameras) small size ~ 2-3 SMALL AREA RADIOGRAPHY - DENTAL RADIOGRAPHY X-Ray Intensifying Screen directly attached to CCD under computer control Images displayed on computer in a few seconds Pixel size 30 um 2 Resolution 15 Lp/mm Dental Radiography, DR Courtesy Alameda Animal Hosp. Digital Dental Radiographs Large Area CCD DR Radiography Aim to Record Image of a 14 x17 Region (14 x 17 X-Ray Intensifying Screen) Image Recorded on Small CCD Chip (camera technology) Courtesy of SEDECAL USA Inc. 13

14 Vet Ray Technology Courtesy of SEDECAL USA Inc. Courtesy of Large Area Single CCD Chip DR Radiography Problems: Bulky device Inefficient collection of light, limits resolution Built in grid will increase exposure need for extremity imaging Precludes using horizontal beam radiography May require higher X-ray exposures than film/screen and other digital acquisition devices Large Area Multiple (Tiled) CCD Chips Smaller in size Improved collection of light 4 Stitching of input from adjacent CCD chips may create artifacts Courtesy of RF System Lab Digital Radiology Plate Types Indirect Types Direct Types Laser scanned Anatomic specific image processing No scanning image processing Anatomic specific processing No scanning 14

15 ADVANTAGES Eliminate cassettes Patient side image viewing Portable System Customized for Veterinary Imaging Indirect DR detector 9 x 11 Plate - Higher resolution megapixels - Pixel size 100 microns 2 14 x 17 Plate - Lower resolution megapixels - Pixel size 160 microns 2 Table Mounted for Small Animal Radiography Courtesy of Eklin Medical Systems, Inc. Courtesy of Eklin Medical Systems, Inc. Small Animal Imaging Table top or in Grid tray 2232 x 3200 pixels Pixel size 127 um 2, 3. 9 Lp/mm DR Electronic Plate Radiography Advantages No processing, almost immediate (5-10 sec) image acquisition No cassettes Potential for excellent image quality when image processing is optimized for animal anatomy Courtesy of Sound Technologies Inc. 15

16 DR Electronic Plate Disadvantages May require greater X-ray exposures than for faster speed film screen radiographs Considerably more expensive than other forms of DR & Computed Radiography Retrofitting to an existing X-Ray table may be challenging Cannot perform cross table radiography The imaging sensor is very expensive to replace 16

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen

More information

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950 HIGH PERFORMANCE MOBILE SURGICAL C-ARM 1K x 1k CCD Digital Camera System H.F. GENERATOR & ROTATING ANODE TUBE WITH DIGITAL WORKSTATION DESCRIPTION: Mobile Surgical C-arm systems are integrated with a triple

More information

Digital radiography conquers the veterinary world

Digital radiography conquers the veterinary world Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing

More information

Page: 1 of 6 Page: 1 of 6

Page: 1 of 6 Page: 1 of 6 Page: 1 of 6 Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique

More information

Quality Control and Maintenance Programs

Quality Control and Maintenance Programs Quality Control and Maintenance Programs Cari Borrás, D.Sc., FACR, FAAPM Visiting Professor DOIN-DEN / UFPE Recife, Pernambuco, Brazil Co-Chair, IUPESM Health Technology Task Group 1 Medical Imaging Equipment

More information

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography Name: Date: Team: Lab Experiment # 3 Focused Grid Positioning Errors Computed Radiography and Direct Digital Radiography Purpose This experiment is designed to demonstrate the effect of off-level error,

More information

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids Principles of Imaging Science II (RAD 120) Radiographic Grids 1 Image-Forming X-Rays Four X-ray paths a. X-rays interact with patient and scatter away from the receptor b. X-rays interact and are absorbed

More information

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through

More information

The Convenient and Compact CR System for Veterinary Practices

The Convenient and Compact CR System for Veterinary Practices The Convenient and Compact CR System for Veterinary Practices Fire CR+ 20 / 40 / 60 / 80 vet with a throughput of 20 to 70 cassettes per hour and the option of a space - saving wall mount The small and

More information

Overview of Digital Detector Technology

Overview of Digital Detector Technology Overview of Digital Detector Technology J. Anthony Seibert, Ph.D. Department of Radiology University of California, Davis Disclosure Member (uncompensated) Barco-Voxar Medical Advisory Board ALARA (CR

More information

Dental Radiography Core Subject. Digital Radiography

Dental Radiography Core Subject. Digital Radiography Dental Radiography Core Subject Digital Radiography Aims: To develop an understanding of the history of digital radiography, the different types of digital x-rays and the advantages and disadvantages of

More information

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams EPEX Direct-to-Digital System for General Radiography Featuring... Versatility for a complete range of general radiographic exams The Hologic EPEX General Radiography System is a direct-to-digital, fully

More information

The convenient and compact CR system for veterinary practices

The convenient and compact CR system for veterinary practices Divario CR-Fvet with dicom PACS DX-R Software CR Systems for the Future The convenient and compact CR system for veterinary practices Divario CR-F20/ F40/ F60/ F80 vet Divario CR-F20/ F40/ F60/ F80 vet

More information

Scanners and How to Use Them

Scanners and How to Use Them Written by Jonathan Sachs Copyright 1996-1999 Digital Light & Color Introduction A scanner is a device that converts images to a digital file you can use with your computer. There are many different types

More information

DR Retrofit Kit 1417 WL Configuration Integrated PACS

DR Retrofit Kit 1417 WL Configuration Integrated PACS DR Retrofit Kit 1417 WL Configuration Integrated PACS Description: The DR Retrofit Kit 1417WL - Configuration Integrated PACS makes the use of CR Cassettes/Imaging Plates or the use of analogue x-ray films,

More information

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X DIGITAL X-RAY SYSTEM with ceiling mounted tube support Universal Digital Radiographic System Conventional system, full DR components Best-in-class image quality Flexible connectivity to PACS systems General

More information

Conventional film intensifying screen

Conventional film intensifying screen Article #4 CE Breakthroughs in Radiography: Computed Radiography John S. Mattoon, DVM, DACVR The Ohio State University Carin Smith, DVM* Smith Veterinary Consulting Peshastin, Washington ABSTRACT: Computed

More information

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General

More information

INTRODUCTION. A. Purpose

INTRODUCTION. A. Purpose New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programs Computed Radiography INTRODUCTION A. Purpose This guide describes

More information

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Radiographic Image Production X-ray photons emitted from the x-ray tube interact with the body, exit the patient (exit beam) and interact

More information

ADDIS-Pod2, a turnkey digital podiatry x-ray system w/ APUS hi frequency generator.

ADDIS-Pod2, a turnkey digital podiatry x-ray system w/ APUS hi frequency generator. podiatric x ray, digital pod, digital detector,... http://addissystem.com/pod2/ 1 of 5 ADDIS-Pod2, a turnkey digital podiatry x-ray system w/ APUS hi frequency generator. Model 128A-S (APUS Included) Shown

More information

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer X-rays were discovered by W.C. Roentgen because of their ability to cause fluorescence. X-ray photons cannot be seen. The image produced

More information

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7) Q.A. Collectible Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7) Mammography Phantom Image Quality Evaluation (from the American College of Radiology 1999 Mammography Quality

More information

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral Dental Radiography X-rays for dental radiography are produced by high voltages of electricity within an x-ray head and come out through a metal tube called a collimator. This ensures the x-rays only come

More information

Digital Dental X-ray. Midmark Animal Health Products

Digital Dental X-ray. Midmark Animal Health Products Digital Dental X-ray Midmark Animal Health Products Disease you can't see... 60% of periodontal disease lies below the gum line, and many issues aren't detectable via probing or visual inspection.* Don't

More information

Understanding Digital Modalities: System Integration and Use

Understanding Digital Modalities: System Integration and Use Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI donaldp@rad.hfh.edu Dicom Digital Imaging and Communications in Medicine Part 3: Information

More information

Digital Mammography Update: Design and Characteristics of Current Systems

Digital Mammography Update: Design and Characteristics of Current Systems : Design and Characteristics of Current Systems Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington AAPM Annual Meeting 2009 Anaheim,

More information

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT Although the medical uses of X-rays to examine a patient without surgery became an amazing medical breakthrough,

More information

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS Note: This is a courtesy copy and is not the official version of this rule. The official, legally effective version of this rule is available through www.lexisnexic.com/bookstore (Phone: (800) 223-1940).

More information

Picture archiving and communication systems (PACS) and guidelines on diagnostic display devices

Picture archiving and communication systems (PACS) and guidelines on diagnostic display devices IT Guidance Documents Picture archiving and communication systems (PACS) and guidelines on diagnostic display devices Second edition Board of the Faculty of Clinical Radiology The Royal College of Radiologists

More information

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School Digital Breast Tomosynthesis

More information

The Exposure Index and Its Standardization

The Exposure Index and Its Standardization The Exposure Index and Its Standardization Ulrich Neitzel Philips Medical Systems Clinical Science Hamburg, Germany ulrich.neitzel@philips.com Content The Exposure Index (EI) What is it? What is it good

More information

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete

More information

Equipment. Lin muyan. Presented by: CocticaUwititonze Email: costicauwitonze@yahoo.com Cell:+250 (0)7888 44764

Equipment. Lin muyan. Presented by: CocticaUwititonze Email: costicauwitonze@yahoo.com Cell:+250 (0)7888 44764 Digital Medical Radiography Diagnostic (DR) system X-ray Equipment Presented by: CocticaUwititonze Email: costicauwitonze@yahoo.com Cell:+250 (0)7888 44764 Lin muyan 1. Goals 2. Introduction 3. X-ray machine

More information

Quality Control of Full Field Digital Mammography Units

Quality Control of Full Field Digital Mammography Units Quality Control of Full Field Digital Mammography Units Melissa C. Martin, M.S., FACMP, FACR, FAAPM Melissa@TherapyPhysics.com 310-612-8127 ACMP Annual Meeting Virginia Beach, VA May 2, 2009 History of

More information

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D.

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D. Slide 1 Digital Mammography Detector QC Slide 2 Introduction What is FFDM QC and why is it important? Eric A. Berns, Ph.D. What to know before you start eric.berns@gmail.com Overview and compare QC tests

More information

Physics testing of image detectors

Physics testing of image detectors Physics testing of image detectors Parameters to test Spatial resolution Contrast resolution Uniformity/geometric distortion Features and Weaknesses of Phantoms for CR/DR System Testing Dose response/signal

More information

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION 5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION 5.2.1 Task The bremsstrahlung produced by the X-ray tube has a continuous spectrum, limited by the set and spreads

More information

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,

More information

Medical imaging monitors specification guidelines

Medical imaging monitors specification guidelines Medical imaging monitors specification guidelines Document details Contact for enquiries and proposed changes If you have any questions regarding this document or if you have a suggestion for improvements,

More information

A PACS-Aware DICOM Image Object

A PACS-Aware DICOM Image Object Designing and Implementing A PACS-Aware DICOM Image Object For Digital X-ray, Mammography and Intraoral Applications David A. Clunie Quintiles Intelligent Imaging Clear Vision for the Healthcare Industry

More information

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis

Application of Digital Radiography for the Detection and Classification of Pneumoconiosis Application of Digital Radiography for the Detection and Classification of Pneumoconiosis DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention National Institute for Occupational

More information

MEDICAL IMAGING. 90/30 Remote Controlled RF System

MEDICAL IMAGING. 90/30 Remote Controlled RF System MEDICAL IMAGING 90/30 Remote Controlled RF System The Easy solution for your Remote Controlled room Apollo EZ represents the Easy approach for the radiographic/fluoroscopic room and it comes from the experience

More information

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations Alzen,, G., Beiderwellen,, K., Volz,, M., Berthold,, L.D.,

More information

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ

More information

WITHOUT COMPROMISE. Cutting edge screening and detection solutions. www.scanna-msc.com

WITHOUT COMPROMISE. Cutting edge screening and detection solutions. www.scanna-msc.com WITHOUT COMPROMISE Cutting edge screening and detection solutions. www.scanna-msc.com WITHOUT COMPROMISE Cutting edge screening and detection solutions. www.scanna-msc.com CR X-ray system with flexible

More information

Digital Breast Tomosynthesis QC Requirements

Digital Breast Tomosynthesis QC Requirements Digital Breast Tomosynthesis QC Requirements AAPM Spring Clinical Meeting March 8, 2015 Michael S Glaser, MS, DABR Alliance Medical Physics, LLC Learning Objectives 1. GE SenoClaire - Physicist & Technologist

More information

Checklist for the Qualification of Digital Detector Array Systems

Checklist for the Qualification of Digital Detector Array Systems Paper No. 010-12 Checklist for the Qualification of Digital Detector Array Systems 1 February 2012 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction

More information

Chapter 15. Creating the Digital Image. Objectives. Key Terms

Chapter 15. Creating the Digital Image. Objectives. Key Terms Chapter 15 Creating the Digital Image Objectives Describe how a digital image is created and processed. Sequence the steps of image production and evaluation of the digital image. Identify the components

More information

Radiation safety in dental radiography

Radiation safety in dental radiography Radiation safety in dental radiography Dental Radiography Series The goal of dental radiography is to obtain diagnostic information while keeping the exposure to the patient and dental staff at minimum

More information

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1. R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction

More information

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13 Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer

More information

Computed Radiography: Acceptance Testing and Quality Control

Computed Radiography: Acceptance Testing and Quality Control Computed Radiography: Acceptance Testing and Quality Control J. Anthony Seibert, Ph.D. University of California Davis Department of Radiology Sacramento, California Introduction CR is the primary means

More information

Digital Radiography Image Quality: Image Acquisition

Digital Radiography Image Quality: Image Acquisition Digital Radiography Image Quality: Image Acquisition Mark B. Williams, PhD a, Elizabeth A. Krupinski, PhD b, Keith J. Strauss, MS c, William K. Breeden, III, MS d, Mark S. Rzeszotarski, PhD e, Kimberly

More information

Best Practices in Digital Radiography

Best Practices in Digital Radiography WHITE PAPER Best Practices in Digital Radiography Tracy L. Herrmann, M.Ed., R.T.(R); Terri L. Fauber, Ed.D., R.T.(R)(M); Julie Gill, Ph.D., R.T.(R)(QM); Colleen Hoffman, R.T.(R)(M)(CT); Denise K. Orth,

More information

Technical Paper DENTAL MONITOR CALIBRATION

Technical Paper DENTAL MONITOR CALIBRATION Technical Paper DENTAL MONITOR CALIBRATION A REPORT ON DENTAL IMAGE PRESENTATION By Tom Schulte Dental radiographs and oral photographs are often both viewed on the same dental workstation monitor. The

More information

Performance testing for Precision 500D Classical R/F System

Performance testing for Precision 500D Classical R/F System Performance testing for Precision 500D Classical R/F System John M. Boudry, Ph.D. Image Quality Systems Engineer GE Healthcare Technologies Outline System background Image Quality Signature Test (IQST)

More information

Digitization of Old Maps Using Deskan Express 5.0

Digitization of Old Maps Using Deskan Express 5.0 Dražen Tutić *, Miljenko Lapaine ** Digitization of Old Maps Using Deskan Express 5.0 Keywords: digitization; scanner; scanning; old maps; Deskan Express 5.0. Summary The Faculty of Geodesy, University

More information

Bergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture

Bergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture Course Information: Course title: Advanced Imaging Equipment and Patient Care Course Code: RAD 184 Credits: 2.0 (30 lecture hours) Pre-requisites: RAD 276 - Imaging Equipment RAD 281 - Radiography II RAD

More information

Radiation safety in dental radiography

Radiation safety in dental radiography Radiation safety in dental radiography Kodak s dental radiograph series The goal of dental radiography is to obtain diagnostic information while keeping the exposure to the patient and dental staff at

More information

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging CR30-ORACLE CR with Office Viewer A Revelation in Computed Radiography Innovations in Digital Imaging Solution for Quantum Medical Imaging CR30-ORACLE CR with Office Viewer The CR30-ORACLE CR System Package

More information

Users Manual Model #93711. English

Users Manual Model #93711. English Users Manual Model #93711 English Congratulations on your purchase of the Celestron NexImage 5 Solar System imaging camera. Your NexImage camera comes with the following: + NexImage 5 Camera + 1.25 nose

More information

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology Guidelines on education and training for digital radiology Author:

More information

George W. Seeley, Ph.D.*t. Kevin MCNeiII, M.S.t. William J. Dallas, ph.d.*t. Past

George W. Seeley, Ph.D.*t. Kevin MCNeiII, M.S.t. William J. Dallas, ph.d.*t. Past RathoGphlcsdexten Displays in radiology: Curnutafiveindoxterms: Past, present, a nd future George W. Seeley, Ph.D.*t Kevin MCNeiII, M.S.t William J. Dallas, ph.d.*t Past. Almost immediately after Wilhelm

More information

MQSA Quality Control Manual for Monochrome Displays for Mammography

MQSA Quality Control Manual for Monochrome Displays for Mammography MQSA Quality Control Manual for Monochrome Displays for Mammography Ver1.0 Applicable Models LMD-DM50, LMD-DM30 Sony Corporation - 1 - MQSA Quality Control Manual for Monochrome Displays for Mammography

More information

K ODAK D IRECTV IEW CR 850 SYSTEM

K ODAK D IRECTV IEW CR 850 SYSTEM CR 850 SYSTEM A fast, premium single-cassette CR system HEALTH IMAGING A BETTER V IEW OF L IFE. CR 850 SYSTEM A FAST, PREMIUM SINGLE-CASSETTE CR SYSTEM FOR PRODUCTIVE X-RAY IMAGING Boost productivity with

More information

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation LORAD Stereotactic Breast Biopsy System AAPM Spring Clinical Meeting Phoenix, AZ March 17, 2013 Melissa C. Martin, M.S., FACR,

More information

Easy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology

Easy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology Easy Quality Control with - PTW Equipment Code of Practice - Quality control of X-ray equipment in diagnostic radiology Revised edition October 2010 Code of Practice- Quality control of X-ray equipment

More information

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY The American College of Radiology, with more than 30,000 members, is the principal organization of radiologists, radiation oncologists, and clinical medical physicists in the United States. The College

More information

CR 30-Xm. CR 30-Xm Digitizer

CR 30-Xm. CR 30-Xm Digitizer D I G I T I Z E R CR 30-Xm Complete solution for digital mammography and all general radiography applications The CR 30-Xm is a versatile computed radiography (CR) digitizer that can handle digital mammography,

More information

QUALITY ASSURANCE IN DENTAL RADIOGRAPHY. Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000

QUALITY ASSURANCE IN DENTAL RADIOGRAPHY. Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000 QUALITY ASSURANCE IN DENTAL RADIOGRAPHY Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000 Quality Assurance (QA) Ensure consistently adequate diagnostic information whilst keeping doses

More information

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ. Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ., Raleigh, NC One vital step is to choose a transfer lens matched to your

More information

Synthetic Sensing: Proximity / Distance Sensors

Synthetic Sensing: Proximity / Distance Sensors Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,

More information

WHO CARES ABOUT RESOLUTION?

WHO CARES ABOUT RESOLUTION? WHO CARES ABOUT RESOLUTION? At Poli we certainly do not care about resolution as a concept! However we do care deeply about resolution when used as a measure of quality. Resolution is a very dry and technical

More information

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology

More information

X-Mind. Instinct for perfection

X-Mind. Instinct for perfection X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in

More information

DICOM Correction Item

DICOM Correction Item Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes

More information

Staff Doses & Practical Radiation Protection in DEXA

Staff Doses & Practical Radiation Protection in DEXA Patient Xray X Doses Staff Doses & Practical Radiation Protection in DEXA Una O ConnorO Dept. of Medical Physics & Bioengineering, St. James s s Hospital. Examination Types General XrayX Fluoroscopy /

More information

Overview. Digital X-ray imaging

Overview. Digital X-ray imaging Overview Digital X-ray imaging The OR Technology competence group: Your competent partner for digital X-ray imaging Producing digital X-ray technology and developing image management systems for use in

More information

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES (a) Applicability Quality assurance programs as described in paragraph (c) of this section are recommended for all diagnostic radiology facilities.

More information

X-ray Imaging Systems

X-ray Imaging Systems Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures

More information

Unit A451: Computer systems and programming. Section 2: Computing Hardware 4/5: Input and Output Devices

Unit A451: Computer systems and programming. Section 2: Computing Hardware 4/5: Input and Output Devices Unit A451: Computer systems and programming Section 2: Computing Hardware 4/5: Input and Output Devices Input and Output devices Candidates should be able to: (a) understand the need for input and output

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY DIAGNOSTIC (VETERINARY) SECTION 1:

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MAMMOGRAPHY) SECTION

More information

White Paper. Advances in Imaging to Improve Output Quality. April 2015. The Xerox Versant and EFI Fiery Digital Front End.

White Paper. Advances in Imaging to Improve Output Quality. April 2015. The Xerox Versant and EFI Fiery Digital Front End. White Paper April 2015 Advances in Imaging to Improve Output Quality The Xerox Versant and EFI Fiery Digital Front End Service Area On Demand Printing & Publishing Consulting Service Comments or Questions?

More information

Consistency of Softcopy and Hardcopy: Preliminary Experiences with the new DICOM Extensions for Image Display

Consistency of Softcopy and Hardcopy: Preliminary Experiences with the new DICOM Extensions for Image Display Consistency of Softcopy and Hardcopy: Preliminary Experiences with the new DICOM Extensions for Image Display Marco Eichelberg a, Jörg Riesmeier a, Klaus Kleber b, Jörg Holstein b, Herman Oosterwijk c,

More information

Radiologic Technology (RAD, CLE) courses are open only to Radiologic Technology majors.

Radiologic Technology (RAD, CLE) courses are open only to Radiologic Technology majors. RADIOLOGIC TECHNOLOGY (A.A.S Degree) Director: Prof. Virginia Mishkin, M.S., R.T. (R) (M) (QM) A radiologic technologist is a skilled professional who provides a specialized health care service. This rewarding

More information

Hardware Guide for the Classic and Elite CR Systems. 2011-08-04 PN 9G9637 Version 1.0

Hardware Guide for the Classic and Elite CR Systems. 2011-08-04 PN 9G9637 Version 1.0 Hardware Guide for the Classic and Elite CR Systems 2011-08-04 PN 9G9637 Version 1.0 Use of the Content Carestream Health CR Systems are designed to meet international safety and performance standards.

More information

Rodenstock Photo Optics

Rodenstock Photo Optics Rogonar Rogonar-S Rodagon Apo-Rodagon N Rodagon-WA Apo-Rodagon-D Accessories: Modular-Focus Lenses for Enlarging, CCD Photos and Video To reproduce analog photographs as pictures on paper requires two

More information

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 2166-Handout College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 13 September - 1 October, 2010 Digital Radiography Image Parameters SNR,

More information

Cutting Edge Digital Radiography Technology in Daily NDT Use

Cutting Edge Digital Radiography Technology in Daily NDT Use Cutting Edge Digital Radiography Technology in Daily NDT Use Ron PINCU, Eli DAYAN, Ofra KLEINBERGER Vidisco Ltd. Or-Yehuda, Israel 60375 Tel: +972 (3) 533-3001 Email: ndt@vidisco.com ABSTRACT Digital Radiography

More information

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy Microscopy from Carl Zeiss AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy New Dimensions in Performance AxioCam MR from Carl Zeiss Both

More information

Product Catalogue EXAMION Systems

Product Catalogue EXAMION Systems EN Product Catalogue EXAMION Systems... A SYSTEM OF CHOICES INTRODUCTION EXAMION - a business division of Arzt & Praxis GmbH is a worldwide supplier of systems in the field of digital and conventional

More information

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC CHAPTER 5 QC Test For Radiographic Equipment Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC Lesson Outcomes Describe the objectives of each QC test done.(importance)

More information

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION Publication Date: November 2010 Implementation Date: March 2011 The purpose of the American Registry of Radiologic Technologists Fluoroscopy Examination

More information

AXIOM Artis U The little big one for universal angiography and cardiology applications

AXIOM Artis U The little big one for universal angiography and cardiology applications AXIOM Artis U The little big one for universal angiography and cardiology applications AXIOM The versatile system for universal angiography and cardiology applications Unchain your workflow! Ease of Use

More information

Dealer Product Letter

Dealer Product Letter Dealer Product Letter DEAR VALUED PARTNERS, With new partners and products, it s important that Viztek remain in communications with you regarding our most up-to-date offerings. It is our goal to keep

More information

ACR AAPM SIIM PRACTICE PARAMETER FOR DIGITAL RADIOGRAPHY

ACR AAPM SIIM PRACTICE PARAMETER FOR DIGITAL RADIOGRAPHY The American College of Radiology, with more than 30,000 members, is the principal organization of radiologists, radiation oncologists, and clinical medical physicists in the United States. The College

More information

Picture Archiving and Communication systems

Picture Archiving and Communication systems Picture Archiving and Communication systems (PACS) By: Somayeh nabiuni 1 Major limitations of the conventional radiology practice Wasted time - implying diagnostic results many not be obtained in a timely

More information

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays J. E. Wilhjelm Ørsted TU Technical University of enmark, Bldg. 348, K-2800 Kongens Lyngby, enmark. X-ray and Computed Tomography Contents History and characterization of X-rays Conventional (projection)

More information