1 Page: 1 of 6 Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique image receptors to capture an analog image and sophisticated readers to process the image and convert the information into a digital format. Since Computed Radiography (CR) utilizes digital technology, images may be electronically manipulated to adjust contrast and density. The computer-generated images obtained with CR can be displayed electronically and/or on film. Historical Perspective Electronic imaging technologies and image management systems offer the capabilities to attain needed efficiencies. Many digital imaging technologies are presently utilized such as Computed tomography (CT) and diagnostic medical sonography, however, general radiography (a predominantly analog process), represents 60-80% of all diagnostic radiography examinations. To meet this need, Computed Radiography was introduced in 1981 by FUJIFILM at the International Congress of Radiography in Brussels and at the Radiological Society of North America in Chicago. The FCR 101 was the first available clinical system and was released in However, widespread adoption of Computed Radiography lagged behind other computer-driven modalities, primarily because digitization of analog data produced reductions in the quality and quantity of information. As such, technological improvements were needed to meet the quality standards essential for the performance of highly detailed, general radiographic examinations. Subsequently, Fuji focused on CR system improvements in key clinical areas: Improved processing speed, higher spatial resolution, reducing patient exposure, and the augmentation of data storage and transmission to provide timely retrieval and communication through the use of industry standards such as DICOM. What is a Digital Image? Digital images are described in terms of numeric values displayed in an array of rows and columns or Pixels (picture elements); this array of pixels is termed a Matrix. The pixel is the smallest component of the matrix and the quantity of information in each pixel is determined by the number of bits (binary digits) of information per pixel. Corresponding to a specific anatomical location, each pixel represents the x-ray intensity by a numeric value corresponding to a particular area on the image. Effective Date: 08/2007

2 Page: 2 of 6 Introduction to Fuji Computed Radiography (CR) Computed Radiography (CR) refers to the use of Photostimulable Storage Phosphors (PSP) for projection of X-ray imaging. In lieu of conventional screen/film, an imaging plate (IP) is used within a specially designed cassette. Imaging Plate The IP is comprised of multiple layers. The top layer is a protective layer and is a thin, transparent layer used to guard against damage caused by handling. The photostimulable phosphor layer serves as the functional layer of the IP by storing energy absorbed from the x-ray exposure. Information obtained through the initial stimulus or primary excitation (x-ray exposure) is stored in the phosphor and later read out when light or a secondary stimulus is applied to the phosphor layer. This phenomenon is called a photostimulable luminescence and makes energy storage possible within the crystal. The phosphor layer is comprised of barium fluorohalide in combination with a small amount of europium. The europium acts as an activator replacing some of the barium atoms and creating a luminescence-center in the crystal that becomes ionized by the incident radiation and is the site where energy (information) is stored as a latent image. The latent image is formed within the crystal following the transfer of energy by a photoelectric interaction. During image processing, a secondary stimulation created by a laser beam scan of the IP causes the crystal to emit blue-violet light proportionate in intensity to the x-ray energy absorbed. The electroconductive layer provides a certain amount of flexible rigidity to the IP; it also protects the phosphor layer from extraneous forces and shocks. There are additional support and light shielding layers added for additional protection and to inhibit reflection of the laser light. For some plate types, a backing layer is employed, and a barcode label is attached to identify each imaging plate. For Dual Side reading FCR devices, the shielding and backing layers are replaced with a transparent backing layer that allows for the collection of PSL from both sides of the IP simultaneously. Imaging Plates synopsis: The IP is used to capture the image It is very important to note that the IP is more sensitive to all types of radiation than conventional intensifying screen phosphors. o Direct o Scatter o Natural Background Radiation Ambient radiation can increase mottle, lower contrast, and have an affect on image quality. Any IP not used within 48 hours should be erased before use. The IP is housed within a special cassette that looks very similar to a conventional screen/film cassette. Latches Barcode Window A green stripe is on the tube-side as reference guide for image orientation.

3 Page: 3 of 6 CR Imaging Process 1. Using standard X-ray equipment, the IP (within the cassette) is exposed. The x-ray photons pass through the subject and strike the IP to form the latent image. 2. The IP is typically bar-coded at an Image and Information Processing (IIP) station to ensure proper processing. 3. The Cassette is then inserted into the CR Reading Unit and the IP is mechanically removed for processing. 4. The IP is transported through the system where it is scanned by a laser beam. The stored energy is released from the IP in the form of light, known as Photostimulable Luminescence (PSL). 5. The PSL is collected and passed through a photomultiplier, then converted to a digital signal. 6. Data recognition processes occur to meet the specified diagnostic need. The signals are reconstructed for output with a specified set of image processing parameters applied. The image can be sent to another Computer and/or Laser printer. 7. After the readout and image processing is completed, the IP is exposed to high intensity light erasing any latent image. 8. The IP is then returned to the cassette, ready to be used for another image acquisition. CR Reading System As a laser scans the IP, light is emitted where X-ray stimulated the phosphor during exposure OPTICAL SCANNER PHOTOMULTIPLIER TUBE LASER BEAM A/D Converter IMAGING PLATE Motor EDR (Exposure Data Recognizer) EDR is an automatic image adjustment function that provides optimum density and contrast even when the exposure conditions vary. A histogram is created based upon menu selection, centering/positioning, and collimation/scatter. The size and shape of the histogram will determine the appearance of the image. The proper EDR mode should be selected based upon the imaging conditions as described in the following information. AUTO Mode is the default mode and will work for the majority of the exams. The EDR mode can be selected/modified at the IIP after the menu has been selected and study started, prior to inserting the cassette into the CR Reader Unit.

4 Page: 4 of 6 EDR AUTO MODE (Centering/positioning important) Density and Contrast will be automatically applied based upon the Default processing parameters for the menu selected. AUTO Collimation recognition Complete Histogram analysis EDR SEMI MODE (Use for tightly collimated images) Centering must be precise. Density only will be automatically Applied. Fixed L value Small reading area No collimation detection done Proper kvp must be used to maintain subject contrast EDR-SEMI-X (Use when centering is not possible) Fixed L value Area of interest is Selected Same precautions as Semi-Mode Must know where the Green stripe is in relation to AOI. Helpful in cross-table exams EDR FIXED MODE The Fixed Mode will give the image a light or dark appearance base on the amount of exposure used. This is similar to screen/film system when a manual technique is used. The Fixed Mode is best used for the problem image, for example: X-Table Hips C7-T1 Laterals Any Image with a lot of Metal Hardware Images that cannot be centered properly

5 Page: 5 of 6 Fuji Computed Radiography FAQs Question: Why are we switching to Computed Radiography (CR)? Answer: CR has been shown to improve department efficiency and workflow, reduce image retakes due to exposure errors, and is a key technology enabling the adoption of PACS. Question: What is the System Speed of FCR? Answer: FCR should be considered a multi-speed system. The imaging plate employs a linear capture of exposure exceeding the capabilities of film/screen systems. FCR is not density or contrast limited but is noise limited. Question: Can I use the same techniques as before? Answer: For some exams the exposure factors will be the same. This is highly dependent on the currently deployed film/screen system speed. Question: Can I continue to use phototiming with FCR? Answer: Yes. A requirement for the use of phototiming with FCR is that calibration must be completed before using CR Cassettes and Imaging Plates. When a phototimer is used, the resulting mas can change depending upon the type of cassette and detector (due to the absorption and backscatter characteristics of the cassette/detector). As the density of the image is controlled by the FCR processing, this calibration must be completed as described in the Fuji CR Users Guide Question: Can I acquire multiple images on the same Cassette/IP? Answer: Yes*. Collimated borders are detected as part of the Exposure Data Recognizer (EDR) processing. For best results, the collimated borders should be sharp and well defined. This ensures that unnecessary information, such as scatter; outside the collimated edges will be eliminated from the analysis. This process is often referred to as PRIEF (Pattern Recognizer for Irradiated Exposure fields). See the CR Users Guide for guidelines in exposure patterns. Note* when delivering images to PACS, multiple images obtained on a single cassette will limit the individual control of image enhancements and must be taken into consideration. For that reason, many facilities that have employed PACS prefer that only one image is acquired per cassette/ip. Question: When should multiple views not be done on the same cassette? Answer: When the thickness of the anatomy varies such as an AP and Lateral. The CR Reader Unit will average both images and poor quality will result. Question: What is the significance of the green stripe on my CR cassettes? Answer: The green stripe is used as a reference for image orientation and should be placed at the cephalic/top of the image in the portrait orientation. For landscape orientation (crosswise) the green stripe should be toward the patient s right side. Incorrect image orientation should be corrected prior to sending images to PACS or the Laser Printer. Question: What is the significance of the S Value? Answer: The Sensitivity number, so-called S Value is an indicator of the Photostimulable Luminescence (PSL) given off by the imaging plate (IP) while being scanned by the laser. The values are inversely proportional to the amount of radiation that strikes the IP.

6 Page: 6 of 6 Question: What is the significance of the L value? Answer: The Latitude value, so called L value is as important as the S Value when critiquing a CR image. For most clinical imaging, L values typically range between 1.6 and 2.3. When L values are outside this range, the result can also be an abnormal S Value. Question: Is radiation exposure the only factor that affects the S Value? Answer: No. The following factors can affect the S Value: Scatter Positioning and centering. Distance SID and OFD Proper use of Grids Collimation Improper Exam selection at the IIP Failure to erase IP if it has not been used for 48 hours or longer Delay in processing from time of exposure Question: If my S number is out of the recommended range, should I change it to be within the recommended range? Answer: In most cases it is NOT recommended. The S Value should not be altered unless the image data is compromised due to an over correction of the Exposure Data Recognizer (EDR). For example, this can occur when the S Value goes below 25 and L Value is greater than 2.0. These images typically appear completely whitened out after the EDR is applied; however, the image details were present during the initial plate reading. Question: What are the differences between the NETWORK list, TODAY list, ALL list, DELIVERED list, and the LOCAL WL? Answer: Network list contains the patients to be done. This will link to the procedure ordered at the RIS/HIS system. Today list shows patients completed today. All list shows all the patients completed, including today and prior to today. Delivered list shows all the patients completed with the study delivered to any destination such as a printer and/or PACS. Local list shows patients that have been registered at the IIP with menus picked and suspended or reserved waiting for the exam to be performed.

Diagnostic X-ray Tube. Producing a radiograph(1) Overview - Equipment found in a general X- ray room

Diagnostic X-ray Tube. Producing a radiograph(1) Overview - Equipment found in a general X- ray room Radiographic Science Basic Overview of diagnostic radiography Marc Griffiths Overview - Equipment found in a general X- ray room Diagnostic X-ray tube Tube support Mechanism Diagnostic Table Upright stands

More information

Digital radiography conquers the veterinary world

Digital radiography conquers the veterinary world Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing

More information

INTRODUCTION. A. Purpose

INTRODUCTION. A. Purpose New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programs Computed Radiography INTRODUCTION A. Purpose This guide describes

More information

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General

More information

Chapter 16 Physics of Diagnostic X-Rays

Chapter 16 Physics of Diagnostic X-Rays 1895, W. C. Roentgen Discovery of x-ray The first x-ray image: Fig.16.1 Radiology Diagnostic radiology (radiologist) Radiation therapy (therapeutic radiologist) Nuclear medicine 1. Production of X-Ray

More information

Digital Mammography Update: Design and Characteristics of Current Systems

Digital Mammography Update: Design and Characteristics of Current Systems : Design and Characteristics of Current Systems Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington AAPM Annual Meeting 2009 Anaheim,

More information

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Radiographic Image Production X-ray photons emitted from the x-ray tube interact with the body, exit the patient (exit beam) and interact

More information

Radiology. Floron C. Faries, Jr. DVM, MS

Radiology. Floron C. Faries, Jr. DVM, MS Radiology Floron C. Faries, Jr. DVM, MS Objectives Determine the appropriate machine settings for making a radiograph Describe essential radiograph accessories Describe the positions used to perform radiographs

More information

Dental Radiography Core Subject. Digital Radiography

Dental Radiography Core Subject. Digital Radiography Dental Radiography Core Subject Digital Radiography Aims: To develop an understanding of the history of digital radiography, the different types of digital x-rays and the advantages and disadvantages of

More information

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids Principles of Imaging Science II (RAD 120) Radiographic Grids 1 Image-Forming X-Rays Four X-ray paths a. X-rays interact with patient and scatter away from the receptor b. X-rays interact and are absorbed

More information

Veterinary Imaging Past, Present and Future- Digital Radiography

Veterinary Imaging Past, Present and Future- Digital Radiography Veterinary Imaging Past, Present and Future- Digital Radiography ROBERT H. WRIGLEY Professor Veterinary Diagnostic Imaging University of Sydney Veterinary Teaching Hospital Professor Emeritus Colorado

More information

Computed Radiography: Acceptance Testing and Quality Control

Computed Radiography: Acceptance Testing and Quality Control Computed Radiography: Acceptance Testing and Quality Control J. Anthony Seibert, Ph.D. University of California Davis Department of Radiology Sacramento, California Introduction CR is the primary means

More information

Interfacing Fuji CR in a DICOM Network Environment

Interfacing Fuji CR in a DICOM Network Environment Interfacing Fuji CR in a DICOM Network Environment Wayne T. DeJarnette, Ph.D., Valmore Albrecht, RT, Alan Orth, RT, Jon Sayer, M.S. DeJarnette Research Systems, Inc. 401 Washington Avenue Towson, MD 21204

More information

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION Publication Date: November 2010 Implementation Date: March 2011 The purpose of the American Registry of Radiologic Technologists Fluoroscopy Examination

More information

Successful Conversion to Digital X-Ray Detectors

Successful Conversion to Digital X-Ray Detectors ECNDT 2006 - Th.3.2.2 Successful Conversion to Digital X-Ray Detectors Leo BOIY, GE Inspection Technologies, Berchem, Belgium Abstract. Conversion of x-ray inspections from film to digital x-ray detectors

More information

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer X-rays were discovered by W.C. Roentgen because of their ability to cause fluorescence. X-ray photons cannot be seen. The image produced

More information

The Exposure Index and Its Standardization

The Exposure Index and Its Standardization The Exposure Index and Its Standardization Ulrich Neitzel Philips Medical Systems Clinical Science Hamburg, Germany ulrich.neitzel@philips.com Content The Exposure Index (EI) What is it? What is it good

More information

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen

More information

A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems

A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems Nikunj Desai a and Daniel J Valentino a,b a icr Company Inc, 2580 West 237th Street, Torrance, CA 90505, USA b Department

More information

Bergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture

Bergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture Course Information: Course title: Advanced Imaging Equipment and Patient Care Course Code: RAD 184 Credits: 2.0 (30 lecture hours) Pre-requisites: RAD 276 - Imaging Equipment RAD 281 - Radiography II RAD

More information

Beam-Restriction. Principles of Imaging Science I (RAD 119) Control of Scatter Using Beam-Restricting Devices. Beam Restrictors Basic Pathology

Beam-Restriction. Principles of Imaging Science I (RAD 119) Control of Scatter Using Beam-Restricting Devices. Beam Restrictors Basic Pathology Principles of Imaging Science I (RAD 119) Beam Restrictors Basic Pathology Beam-Restriction Methods employed or devices used to keep scatter radiation production to a minimum Purpose is to control and

More information

Equipment. Lin muyan. Presented by: CocticaUwititonze Email: costicauwitonze@yahoo.com Cell:+250 (0)7888 44764

Equipment. Lin muyan. Presented by: CocticaUwititonze Email: costicauwitonze@yahoo.com Cell:+250 (0)7888 44764 Digital Medical Radiography Diagnostic (DR) system X-ray Equipment Presented by: CocticaUwititonze Email: costicauwitonze@yahoo.com Cell:+250 (0)7888 44764 Lin muyan 1. Goals 2. Introduction 3. X-ray machine

More information

X-Rays were discovered accidentally in 1895 by Wilhelm Conrad Röntgen

X-Rays were discovered accidentally in 1895 by Wilhelm Conrad Röntgen X-Rays were discovered accidentally in 1895 by Wilhelm Conrad Röntgen Due to their short wavelength, on the order of magnitude of cells, and their high energy, they can penetrate skin and other soft tissue.

More information

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams

EPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams EPEX Direct-to-Digital System for General Radiography Featuring... Versatility for a complete range of general radiographic exams The Hologic EPEX General Radiography System is a direct-to-digital, fully

More information

Principles of X-Ray Imaging

Principles of X-Ray Imaging Principles of X-Ray Imaging 1 Already a few weeks after the discovery of X-rays in 1895 by Wilhelm Conrad R ontgen the first medical images with photographic plates and fluorescent screens were made. This

More information

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT Although the medical uses of X-rays to examine a patient without surgery became an amazing medical breakthrough,

More information

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography

Name: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography Name: Date: Team: Lab Experiment # 3 Focused Grid Positioning Errors Computed Radiography and Direct Digital Radiography Purpose This experiment is designed to demonstrate the effect of off-level error,

More information

The only portable ALL IN ONE Scanner

The only portable ALL IN ONE Scanner C o m p u t e d R a d i o g r a p h y S y s t e m The only portable ALL IN ONE Scanner 2014 GLOBAL VETERINARY COMPUTED RADIOGRAPHY IMAGING NEW PRODUCT INNOVATION LEADERSHIP AWARD www.allpro-imaging.com

More information

Radiographic Quality. Factors Affecting Optical Density: Optimum film/screen image density: 0.25 to 2.5 Milliamperage or ma (primary beam quantity)

Radiographic Quality. Factors Affecting Optical Density: Optimum film/screen image density: 0.25 to 2.5 Milliamperage or ma (primary beam quantity) The Density Unit: Factors Affecting Optical Density: Optimum film/screen image density: 0.25 to 2.5 Milliamperage or ma (primary beam quantity) Primary controlling factor for density Direct and proportional

More information

X-rays Images. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

X-rays Images. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department Discovery: German physicist Wilhelm Röntgen in 1895; "X-rays" signify an unknown quantity; X-rays were found emanating from Crookes tubes

More information

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ

More information

X-ray Photography Scientific/Technological fact sheet

X-ray Photography Scientific/Technological fact sheet Students material Medical Imaging The Glass Patient X-ray Photography Scientific/Technological fact sheet Introduction In 1895, Wilhelm Conrad Roentgen (1845-1923) discovered that when electrons were accelerated

More information

Teaching DR/CR with Best Dose Practices

Teaching DR/CR with Best Dose Practices Teaching DR/CR with Best Dose Practices WCEC 2013 Dennis Bowman RT(R) Clinical Instructor/Staff Radiographer Community Hospital of the Monterey Peninsula (CHOMP) Cabrillo Clinical Instructor Speaker/Consultant

More information

DICOM Correction Item

DICOM Correction Item Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes

More information

Digital Radiography Image Quality: Image Acquisition

Digital Radiography Image Quality: Image Acquisition Digital Radiography Image Quality: Image Acquisition Mark B. Williams, PhD a, Elizabeth A. Krupinski, PhD b, Keith J. Strauss, MS c, William K. Breeden, III, MS d, Mark S. Rzeszotarski, PhD e, Kimberly

More information

Diagnostic X-rays and CT Scans - X-ray vision

Diagnostic X-rays and CT Scans - X-ray vision - X-ray vision http://www.uab.edu/surgonc/cases/gi/case2/ctscanof.htm http://www.museumboerhaave.nl/aacollection/aajpegs/m22/9955.jpg - motivation and outline X-rays have been known for over 110 years.

More information

Radiology Physics. Just take a deep breath. Books to Consider. Why worry about physics? The Game Plan. 1 st Period

Radiology Physics. Just take a deep breath. Books to Consider. Why worry about physics? The Game Plan. 1 st Period Radiology Physics Just take a deep breath OR: I DIDN T SIGN UP TO LEARN THIS STUFF Chris Ober, DVM, PhD, DACVR 7 February 2011 Why worry about physics? Know what the system can give you Know what the system

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MAMMOGRAPHY) SECTION

More information

Physics testing of image detectors

Physics testing of image detectors Physics testing of image detectors Parameters to test Spatial resolution Contrast resolution Uniformity/geometric distortion Features and Weaknesses of Phantoms for CR/DR System Testing Dose response/signal

More information

Best Practices in Digital Radiography

Best Practices in Digital Radiography WHITE PAPER Best Practices in Digital Radiography Tracy L. Herrmann, M.Ed., R.T.(R); Terri L. Fauber, Ed.D., R.T.(R)(M); Julie Gill, Ph.D., R.T.(R)(QM); Colleen Hoffman, R.T.(R)(M)(CT); Denise K. Orth,

More information

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through

More information

A PACS-Aware DICOM Image Object

A PACS-Aware DICOM Image Object Designing and Implementing A PACS-Aware DICOM Image Object For Digital X-ray, Mammography and Intraoral Applications David A. Clunie Quintiles Intelligent Imaging Clear Vision for the Healthcare Industry

More information

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC CHAPTER 5 QC Test For Radiographic Equipment Prepared by:- Kamarul Amin bin Abdullah @ Abu Bakar School of Medical Imaging KLMUC Lesson Outcomes Describe the objectives of each QC test done.(importance)

More information

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS Note: This is a courtesy copy and is not the official version of this rule. The official, legally effective version of this rule is available through www.lexisnexic.com/bookstore (Phone: (800) 223-1940).

More information

Exposure SURE. Low Dose Diagnostic Image Quality. Erin Angel, PhD. Manager, Clinical Sciences, CT Toshiba America Medical Systems, Inc.

Exposure SURE. Low Dose Diagnostic Image Quality. Erin Angel, PhD. Manager, Clinical Sciences, CT Toshiba America Medical Systems, Inc. Exposure Low Dose Diagnostic Image Quality Erin Angel, PhD Manager, Clinical Sciences, CT Toshiba America Medical Systems, Inc. Exposure: Low Dose Diagnostic Image Quality 1 Since its inception, Computed

More information

Quality Control and Maintenance Programs

Quality Control and Maintenance Programs Quality Control and Maintenance Programs Cari Borrás, D.Sc., FACR, FAAPM Visiting Professor DOIN-DEN / UFPE Recife, Pernambuco, Brazil Co-Chair, IUPESM Health Technology Task Group 1 Medical Imaging Equipment

More information

Interim policy effective January 1, 2016, through December 31, 2017

Interim policy effective January 1, 2016, through December 31, 2017 IMPORTANT NOTICE Interim policy announced for post-primary structured education requirement Interim policy relaxes exam content outline requirement (November 12, 2015) The ARRT announces an interim policy

More information

TOUGH RAY 9030 PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL

TOUGH RAY 9030 PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL TOUGH RAY 9030 PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL DRAFT CONTENTS PAGE NO. NOTICE FOR SAFE OPERATION 2 INTRODUCTION 3 NOTES TO USERS 3 COMPONENTS 4 OPERATING CONDITIONS 5 MAIN PARTS

More information

Image acquisition. Autumn 2007 Mikko Liljeström

Image acquisition. Autumn 2007 Mikko Liljeström Image acquisition Autumn 2007 Mikko Liljeström Microscope Objective (Magnification, NA ) Light source Filters Image acquired can not be better than image generated by microscope (but it can be worse )

More information

DIGITAL PORTABLE 4.0/8.0 kw DRAGON LW SYSTEM

DIGITAL PORTABLE 4.0/8.0 kw DRAGON LW SYSTEM DIGITAL PORTABLE 4.0/8.0 kw DRAGON LW SYSTEM WITH TOSHIBA FDX3543RP FLAT PANEL Technical Specifications by DRAGON LW PORTABLE SYSTEM is completely integrated and combines the high frequency x-ray generator

More information

Patient Prep Information

Patient Prep Information Stereotactic Breast Biopsy Patient Prep Information Imaging Services Cannon Memorial Hospital Watauga Medical Center Table Weight Limits for each facility Cannon Memorial Hospital Watauga Medical Center

More information

How does magnification affect image quality and patient dose in digital subtraction angiography?

How does magnification affect image quality and patient dose in digital subtraction angiography? How does magnification affect image quality and patient dose in digital subtraction angiography? Nikolaos A Gkanatsios *a, Walter Huda b, Keith R Peters c a Medical Physics (H-539), Baylor University Medical

More information

3701-72-03 Standards for accreditation of educational programs and approval of continuing education courses.

3701-72-03 Standards for accreditation of educational programs and approval of continuing education courses. 1 3701-72-03 Standards for accreditation of educational programs and approval of continuing education courses. (A) Any person may apply to the director for approval to conduct an educational program for

More information

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology Guidelines on education and training for digital radiology Author:

More information

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the

More information

Overview of Digital Detector Technology

Overview of Digital Detector Technology Overview of Digital Detector Technology J. Anthony Seibert, Ph.D. Department of Radiology University of California, Davis Disclosure Member (uncompensated) Barco-Voxar Medical Advisory Board ALARA (CR

More information

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology

More information

Model SR-130D Direct Capture Digital Product Overview

Model SR-130D Direct Capture Digital Product Overview Welcome! Model SR-130D Direct Capture Digital Product Overview Brandywine Imaging Tel: 800-541-0632 Brandywineimaging@comcast.net 201 west cedar street / Kennett Square, PA 19348 Who We ARE! Source-Ray

More information

LECTURE 6 MOBILE X-RAY UNITS

LECTURE 6 MOBILE X-RAY UNITS LECTURE 6 MOBILE X-RAY UNITS Prepared by:- KAMARUL AMIN BIN ABDULLAH @ ABU BAKAR UiTM Faculty of Health Sciences Medical Imaging Department LESSON OBJECTIVES At the end of lesson, the student should able

More information

LAUE DIFFRACTION INTRODUCTION CHARACTERISTICS X RAYS BREMSSTRAHLUNG

LAUE DIFFRACTION INTRODUCTION CHARACTERISTICS X RAYS BREMSSTRAHLUNG LAUE DIFFRACTION INTRODUCTION X-rays are electromagnetic radiations that originate outside the nucleus. There are two major processes for X-ray production which are quite different and which lead to different

More information

Understanding Digital Modalities: System Integration and Use

Understanding Digital Modalities: System Integration and Use Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI donaldp@rad.hfh.edu Dicom Digital Imaging and Communications in Medicine Part 3: Information

More information

FLAT PANEL DETECTORS. Dedicated Cardiac Cath Lab Biplane Five-Axis

FLAT PANEL DETECTORS. Dedicated Cardiac Cath Lab Biplane Five-Axis FLAT PANEL DETECTORS Dedicated Cardiac Cath Lab Biplane Five-Axis Advanced technologies deliver optimized biplane imaging Designed in concert with leading pediatric physicians, the Infinix CF-i/BP provides

More information

Outcomes Assessment Plan Radiologic Technology Program Austin Community College Graduating Class of 2012

Outcomes Assessment Plan Radiologic Technology Program Austin Community College Graduating Class of 2012 Outcomes Assessment Plan Radiologic Technology Program Austin Community College Graduating Goal #1: Upon completion of the program, the graduate will satisfactorily demonstrate Entry Level Clinical Competency

More information

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Qiang Lu Chapter 3. System Scanning Hardware Overview 79 Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Since all the image data need in this research were collected from the highly modified AS&E 101ZZ system,

More information

Radiation safety in dental radiography

Radiation safety in dental radiography Radiation safety in dental radiography Dental Radiography Series The goal of dental radiography is to obtain diagnostic information while keeping the exposure to the patient and dental staff at minimum

More information

Introduction to Medical Imaging - Medical Student Clerkship Lecture

Introduction to Medical Imaging - Medical Student Clerkship Lecture PATIENT CARE IN RADIOLOGY Introduction to Medical Imaging CLINICAL Kalpana M. Kanal, PhD, DABR Assistant Professor, Diagnostic Physics Dept. of Radiology UW Medicine a copy of this lecture may be found

More information

Froedtert Hospital School of Radiology Curriculum Analysis Grid. Clinical Practice

Froedtert Hospital School of Radiology Curriculum Analysis Grid. Clinical Practice Professional Curriculum Clinical Practice Procedural Performance Clinical Competency Basic Principles of Digital Radiography Image Acquisition Image Acquisition Errors Fundamental Principles of Exposure

More information

Shielding for Diagnostic X-rays: UK Guidance. Jerry Williams

Shielding for Diagnostic X-rays: UK Guidance. Jerry Williams Shielding for Diagnostic X-rays: UK Guidance Jerry Williams Royal Infirmary of Edinburgh BIR/ IPEM Working Party Report British Institute of Radiology Institute of Physics and Engineering in Medicine Working

More information

MEDICAL IMAGING. 90/30 Remote Controlled RF System

MEDICAL IMAGING. 90/30 Remote Controlled RF System MEDICAL IMAGING 90/30 Remote Controlled RF System The Easy solution for your Remote Controlled room Apollo EZ represents the Easy approach for the radiographic/fluoroscopic room and it comes from the experience

More information

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES (a) Applicability Quality assurance programs as described in paragraph (c) of this section are recommended for all diagnostic radiology facilities.

More information

Advances In and Specifications for Radiographic X-Ray Systems

Advances In and Specifications for Radiographic X-Ray Systems Advances In and Specifications for Radiographic X-Ray Systems Wlad T. Sobol, Ph.D. Radiology Department University of Alabama Health System The University of Alabama at Birmingham Birmingham, Alabama Introduction

More information

Medical X-ray Imaging

Medical X-ray Imaging Medical X-ray Imaging HYBRID PORTABLE X-RAY 20BT / 40BT 20 Light weight, compact size and durable cover The world s only hybrid powered portable X-ray Light weight portable X-ray with high power Hybrid

More information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOSCOPY)

More information

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,

More information

X-ray detection and data acquisition for NDT applications

X-ray detection and data acquisition for NDT applications Abstract X-ray detection and data acquisition for NDT applications J Michael HOMER, Stephen C JAYE Sens-Tech Ltd, Bury Street, Ruislip, HA4 7TA, UK Tel: +44 1895 630771, Fax +44 1895 635953 E-mail: Mike.Homer@sens-tech.com

More information

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School Digital Breast Tomosynthesis

More information

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical

More information

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950 HIGH PERFORMANCE MOBILE SURGICAL C-ARM 1K x 1k CCD Digital Camera System H.F. GENERATOR & ROTATING ANODE TUBE WITH DIGITAL WORKSTATION DESCRIPTION: Mobile Surgical C-arm systems are integrated with a triple

More information

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 2166-Handout College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 13 September - 1 October, 2010 Digital Radiography Image Parameters SNR,

More information

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9 Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation

More information

Chest Radiography for prevalence surveys & active case detection

Chest Radiography for prevalence surveys & active case detection Chest Radiography for prevalence surveys & active case detection Dr Narayan PENDSE Radiologist Visiteur Médécin, Univ Hospital Geneva Expert, Radiology WHO/STB, WHO/EHT drspendse@gmail.com Chest Radiography

More information

Digital Quality Assurance

Digital Quality Assurance Digital Quality Assurance Area Quality Assurance Procedure Frequency Electronic Display Overall visual assessment - general image quality using Daily Device SMPTE & TG18-QC test patterns Performance using

More information

What does DXA mean and why is it important? Principles of operation of DXA systems. How can we measure bone mineral density? What is radiation?

What does DXA mean and why is it important? Principles of operation of DXA systems. How can we measure bone mineral density? What is radiation? What does DXA mean and why is it important? Principles of operation of DXA systems Dr Wil Evans Head of Medical Physics University Hospital of Wales, Cardiff DXA stands for Dual energy X-ray Absorptiometry

More information

QUALITY CONTROL TESTS IN SOME DIAGNOSTIC X-RAY UNITS IN BANGLADESH

QUALITY CONTROL TESTS IN SOME DIAGNOSTIC X-RAY UNITS IN BANGLADESH Bangladesh Journal of Medical Physics Vol. 4, No.1, 2011 QUALITY CONTROL TESTS IN SOME DIAGNOSTIC X-RAY UNITS IN BANGLADESH M. Begum 1, A. S. Mollah 2, M. A. Zaman 3 and A. K. M. M. Rahman 4 1 Health Physics

More information

Production of X-rays and Interactions of X-rays with Matter

Production of X-rays and Interactions of X-rays with Matter Production of X-rays and Interactions of X-rays with Matter Goaz and Pharoah. Pages 11-20. Neill Serman Electrons traveling from the filament ( cathode) to the target (anode) convert a small percentage

More information

Radiation safety in dental radiography

Radiation safety in dental radiography Radiation safety in dental radiography Kodak s dental radiograph series The goal of dental radiography is to obtain diagnostic information while keeping the exposure to the patient and dental staff at

More information

Basic principles of computed tomography. MUDr. Lukáš Mikšík, KZM FN Motol

Basic principles of computed tomography. MUDr. Lukáš Mikšík, KZM FN Motol Basic principles of computed tomography MUDr. Lukáš Mikšík, KZM FN Motol Tomography tomos = slice; graphein = to write definition - imaging of an object by analyzing its slices Damien Hirst Autopsy with

More information

Experiment report. R. Moeckli, F.R. Verdun, J.-F. Valley Institut de Radiophysique Appliquée Centre Universitaire. CH Lausanne.

Experiment report. R. Moeckli, F.R. Verdun, J.-F. Valley Institut de Radiophysique Appliquée Centre Universitaire. CH Lausanne. Experiment report Introduction R. Moeckli, F.R. Verdun, J.-F. Valley Institut de Radiophysique Appliquée Centre Universitaire. CH - 1015 Lausanne Beam time has been allocated on BM5 in September 1998,

More information

X-ray (Radiography) - Abdomen

X-ray (Radiography) - Abdomen Scan for mobile link. X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small dose of ionizing radiation to produce pictures of the inside of the abdominal cavity. It is used to evaluate the stomach,

More information

QUALITY CONTROL PROGRAM. X-Ray Equipment PROCEDURE MANUAL

QUALITY CONTROL PROGRAM. X-Ray Equipment PROCEDURE MANUAL QUALITY CONTROL PROGRAM DEPARTMENT OF RADIOLOGY MARY HITCHCOCK MEMORIAL HOSPITAL DARTMOUTH-HITCHCOCK MEDICAL CENTER LEBANON, NEW HAMPSHIRE X-Ray Equipment PROCEDURE MANUAL June 2009 Table of Contents Quality

More information

STANDARD FOR RADIATION APPARATUS -

STANDARD FOR RADIATION APPARATUS - Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY DENTAL DIAGNOSTIC (INTRAORAL) SECTION

More information

Economic Evaluation of Conventional Radiography with Film and Computed Radiography: Applied at BMC

Economic Evaluation of Conventional Radiography with Film and Computed Radiography: Applied at BMC Advances in Computed Tomography, 2012, 1, 23-29 http://dx.doi.org/10.4236/act.2012.13006 Published Online December 2012 (http://www.scirp.org/journal/act) Economic Evaluation of Conventional Radiography

More information

Using spectral results in CT imaging

Using spectral results in CT imaging Computed tomography Using spectral results in CT imaging Philips IQon Spectral CT Z. Romman, I. Uman, Y. Yagil, D. Finzi, N. Wainer, D. Milstein; Philips Healthcare In clinical practice, CT has become

More information

Checklist for the Qualification of Digital Detector Array Systems

Checklist for the Qualification of Digital Detector Array Systems Paper No. 010-12 Checklist for the Qualification of Digital Detector Array Systems 1 February 2012 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction

More information

RAD 216 ADVANCED IMAGING MODALITIES THOMAS A. EDISON EARLY FLUOROSCOPY IMAGE INTENSIFICATION AND TV IMAGING SYSTEMS

RAD 216 ADVANCED IMAGING MODALITIES THOMAS A. EDISON EARLY FLUOROSCOPY IMAGE INTENSIFICATION AND TV IMAGING SYSTEMS RAD 216 ADVANCED IMAGING MODALITIES IMAGE INTENSIFICATION AND TV IMAGING SYSTEMS THOMAS A. EDISON is credited with the development of fluoroscopy. His work enabled physicians to see DYNAMIC or moving images

More information

Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems

Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems AAPM REPORT NO. 93 Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems Report of AAPM Task Group 10 October 2006 DISCLAIMER: This publication is based on sources

More information

Atomic and Nuclear Physics Laboratory (Physics 4780)

Atomic and Nuclear Physics Laboratory (Physics 4780) Gamma Ray Spectroscopy Week of September 27, 2010 Atomic and Nuclear Physics Laboratory (Physics 4780) The University of Toledo Instructor: Randy Ellingson Gamma Ray Production: Co 60 60 60 27Co28Ni *

More information

Chapter 5 X-ray imaging 5.1 The physics of diagnostic X-rays

Chapter 5 X-ray imaging 5.1 The physics of diagnostic X-rays Chapter 5 X-ray imaging 5.1 The physics of diagnostic X-rays Learning objectives: How are X-rays produced in an X-ray tube? How is the energy of the photons from an X-ray tube controlled? Why are photons

More information

Flash for Selfies. An overview of illuminance requirements and why shorter flash pulses are the preferred solution for front flash.

Flash for Selfies. An overview of illuminance requirements and why shorter flash pulses are the preferred solution for front flash. WHITE PAPER Flash for Selfies An overview of illuminance requirements and why shorter flash pulses are the preferred solution for front flash Introduction Smartphones are ubiquitous in everybody s daily

More information

TI Solutions for Security X-ray

TI Solutions for Security X-ray TI HealthTech Engineering components for life. TI Solutions for Security X-ray Imaging Introduction Purpose To introduce TI s Front End Solutions for X-ray Content X-ray Basics X-ray uses for Security

More information