1 Digital Medical Radiography Diagnostic (DR) system X-ray Equipment Presented by: CocticaUwititonze Cell:+250 (0) Lin muyan
2 1. Goals 2. Introduction 3. X-ray machine structure Content 4. Fundamental condition emerge x-ray 5. Digital radiography innovative 6. Installation and calibration 7. Troubleshooting procedure 8. Conclusion
3 The goals Goals: 1. To understand the Digital radiograph system 2. General structure of x-ray machine 3. Fundamental condition emerge x-ray 3. Installation and calibration process 4. Troubleshooting procedure
4 Introduction Medical imaging play a big role to study the human anatomy and physiology body X-ray based methods of medical imaging include conventional General X-ray radiography machine, computer tomography (CT), mammography and angiography Molecular imaging such as : leaner accelerator, gamma used in nuclear medicine and uses a variety of methods to visualize biological processes taking place in the cells of organisms. Small amounts of radioactive markers used
5 Introduction Other types of medical imaging are magnetic resonance imaging (MRI) and ultrasound imaging. MRI and ultrasound operate without ionizing radiation. MRI uses strong magnetic fields, which produce no known irreversible biological effects in humans. ultrasound systems use the propagation of acoustic waves in attenuating media. high-frequency sound waves to produce images of soft tissue and internal body organs.
6 X-ray machine structure Quick questions 1. Major components of x-ray machine 2. which role of each part 3.What role of filament in the x-ray and which material 4. How the x-ray tube works 5. State three components of x-ray tube 6. What is CR 7. What is IP cassette
7 Answer X-Ray machine structure X-Ray Tube: X-Ray : to generate x-ray and shut High-Voltage Generator: Provide power to X-ray tube Controller: Control kv ma s The role of filament is to generate electrons Peripheral: Machinery and auxiliary device DR : computer Radiographer IP cassette: Image Plate store the image in form of energy.
8 ANALOGUE X-RAY machine structure
9 kvp Selector 3-5 or 12 volts volts 220/380 volts 80,000 to 125,000 volts filament
10 x-ray tube structure X-ray Tube Components 5 9 beryllium window
11 Thermionic Emission Release of electrons from hot filament when current flows after depressing exposure switch x-section hot filament of filament Space charge electrons The hotter the filament, the greater the quantity of electrons that are released, hence the higher the ma
12 X-ray Production 3
13 current flow Autotransformer Incoming 220 Volt line Volts per turn is the same across all turns V
14 Step-Up Transformer 220 volts current flow Primary Volts/turn in the primary Will always equal current flow Secondary Volts/turn in the secondary 65,000 to 90,000 volts
15 Step-Down Transformer 220 volts current flow Primary Volts/turn in the primary Will always equal 3-5 volts current flow Volts/turn in the secondary Secondary
16 Increasing kvp results in: Higher average energy of x-rays Greater maximum energy x-rays More x-rays
17 Quantity of X-rays ma (milliamperes) 10 ma 5 ma maximum energy (no change) average energy (no change) X-ray Energy (kev) 70
18 Quality penetrating ability Quantity number of x-rays
19 How to determine mas milliamperes (ma) x seconds (s) 50 cycles/impulses = 1 second 10 ma x.5 seconds = 5 mas 20 ma x.25 seconds = 5 mas 50 ma x.1 second = 5 mas
20 Increasing ma or Exposure Time results in: An increase in the quantity of x-rays produced No change in the quality of the x-ray beam
21 Automatic expose control Ion chamber Advantages Ionization chambers are used with digital imaging systems (DR or CR) as well as standard film systems. Ionization chambers are the sensors used in Automatic Exposure Control (AEC) systems for x-ray generators. AEC systems provide proper, reproducible film densities by automatically compensating for variables such as patient size, anatomy, pathology and positioning.
22 X-ray emission system
23 Digital Radiography innovative Although X-rays have been in existence since the early 1900s, digital radiography has only been around since However, since that time,. Popular imaging systems in use today include the CR and DR systems. CR, or computed radiography, uses an imaging cassette of phosphor to create digital images, and DR systems, or direct digital radiography, uses a collection plate for image capture. These two systems, along with related hardware and software units such as the DICOM digital format, PACS and RIS, have brought many medical facilities up to the modern age with state-of-the-art digital radiography capabilities.
24 Digital Radiography innovative In the 1990s, a shift in digital radiography was made. X-ray images, it was discovered, could be stored on phosphor screens, and this formed the basis of today's CR imaging systems. Complementary PACS systems had their debut in 1982, in the DICOM imaging format, similar to the common JPEG format, can be stored on a server for archival purposes,
25 What is DR(Digital Radiography)? Digital radiography is a form of X-ray imaging, where digital X-ray sensors are used instead of traditional photographic film. Advantages include time efficiency through bypassing chemical processing and the ability to digitally transfer and enhance images. Also less radiation can be used to produce an image of similar contrast to conventional radiography
26 What is DR(Digital Radiography)? Instead of X-ray film, digital radiography uses a digital image capture device. Advantages 1. Immediate image preview and availability 2. Elimination of costly film processing steps 3. Ability to apply special image processing techniques that enhance overall display of the image.
27 self stand RD with flat panel detector
28 Differents DR design (U arm ) Depend on the user request the manufacture are able to customize the stand goes along with detector and tube
29 Top mounting DR
30 Type of Digital Radiograph In X-ray radiography There are two different way to obtaining the Digital Image 1. Computer Radiography : (CR) by using IP cassette and reader 2. Digital Radiograph :(DR) by using Image detector and processed by CPU and review immediately NOTE: So far the DR has two different types Direct image detector : plat panel detector Indirect detector :by using Charge-Coupled Device (CCD)
31 What is CCD A charge-coupled device (CCD) is a device for the movement of electrical charge, usually from within the device to an area where the charge can be manipulated, for example conversion into a digital value. CCDs move charge between capacitive bins in the device, with the shift allowing for the transfer of charge between bins The CCD is a major piece of technology in digital imaging sensor to achieve a high pixel the apply Metal Oxide Semiconductor (MOS) Capacitor CCD image sensors are widely used in professional, medical, and scientific applications where high-quality image data is required
32 CR PROCESSOR ( IP -READER) The manage is captured on the Imaging Plate (IP) cassette and being processed by IP reader which is connected to the CPU with monitor in order to review the image and share with group of people (PACS ) Condition having DICOM protocol is required
33 CR (Computed Radiography) Semiconductor laser A/D converter CRT controller The Host computer Stimulable phosphor detetor Schematic showing formation of the latent image on the CR imaging plate (1) the plate being scanned by the laser beam (2) light photons being converted to electrical signal (3) and electrical signals being converted to digital signals, which form a CR image
34 IP Cassette processing BaFX Crystals Support X-ray Eeposure X-ray photons Unused Imaging Plate Recording the X-ray Imaging Reading Laser-Beam Scanning Light The Laser Beams Extracts the X-ray Image from the plate by Converting to Light Photo, which from a Light Image Erasing The Small Amount of Residual Image on the Plate is Thoroughly Erased by Flooding the Plate with Light The Erase Plate Can Be Used Again
35 Mobile X-ray machine with DR/ CR Today s technology mobile x-ray comes with DR option : wireless cassette, and CR, IP cassette option with screen which allow you review edit and send the image to the server! ISSN X = University without borders for the open society Volume: 4
36 CCD detector FLAT PANEL DETECTOR Different type of x- ray detector Different type of x-ray director ISSN X = University without borders for the open society Volume: 4
37 Different type of detectors Flat panel detector CCD detector
38 Indirect CCD detector * X-Ray CSI (a fluorescent substance) visible radiation focusing lens CCD Camera DATA (2) Expense is cheaper than FPD method but image processing speed is slow (3) Image quality is low than FPD method and require high dose (4) Geometric false occurs after change light during focusing process
39 * Indirect measuring method (CSI-FPD) CSI changes X-ray to light. a-si: H changes strength of light to electronic signal and send TFT array. It is sensitive to light. (1) X-Ray CSI (a fluorescent substance) visible radiation P h o t o d i o d e electronic signal TFT DATA
40 1. Hardware structure Detector Technology (Indirect / Direct)
41 * Direct measuring method (a-se-fpd) a-se absorbs X-ray photon and high voltage is approved to make ionized Selenium collector electrode collects ionized Selenium and sends TFT array. (1) X-Ray A-Se electronic signal TFT DATA(no light transforming procedure) (2) Comparing indirect DR method, X-ray image is good because it h a s no diffusion of light (3) It needs high voltage approval because of Selenium physical feature. (4) Image reproducibility is not good by ghost effect (5) A manufacturing process is s i m p l e and than indirect DR method but need high ISSN irradiation X = University condition. without
42
43 2. CR and DR comparison to get X-ray image 3) Strength and Weakness Strength(DR) - Availability of various diagnosis - Obtain same image quality - Improve work efficiency - low radiation dosage - Easy data base - Easy application to PACS Weakness (CR) - Need clinical study - Smaller image than real size - Heavy error possibility by wrong set up - Increase clinical expense - low examination efficiency by radiologist work load increase - Slow speed than conventional system
44 Film(Analog Radiography) Digital Radiography Information Capacity Detector Storage 10^2.5(=300; 8 bit) ~ 10^3.5(=3000; 12bit) Limited information capacity depending on brightness of view box. 1500cd/m^2 viewbox brightness: 10^2.8=630 (9 bit) at least 3000cd/m^2 viewbox brightness(mamo): max. 10^3.1=1260(10bit) * The eyes of human can be reading up to 6 bit, therefore after covering up reading area for adjusting the eyes, then reading a image. storage film wareroom Large area requires easy to lose contaminate easily by moisture. 14bit(16384) ~ 16bit(65536) Current maximum monitor brightness: 700cd/m^2 = possibly reading 10^2.5=316(8bit) Brightness/Contrast adjustment requires for reading remain information. Digital storage through hard disk or CD-ROM Copy 30% lose of information for 1 copy. Unlimited Maintenance film cost + developing cost + waste water treatment cost+ developing room rental cost/film wareroom rental/maintain cost + film management (storage/find) cost basic storage device + backup cost (CD-ROM/labor cost) + storage device extension cost Retaking rate abnormality of exposure condition+ film + abnormality of film development contamination and lost Retaking rate is very low. System price USD10,000~USD50,000 USD100,000~USD500,000
45 X-ray hard ware system CCD Detector, tube, generator and console
46 DR SOFTWARE REQUEREMENT IN ORDER TO ACHIEVE THE COMUNICATION BETWEEN THE Detector, Generator and the tube, you must have a communication software compatible with detector the software also communicate with DICOM in order to form digital image format for send and save to Picture Achieving System (PACS) and RIS system
47 X-ray generator: Hv transformer and capacity tank
48 DR software system SOFTWARE COMUNICATION AND REVIEW IMAGE ACQUISITION AND REVIEW
49 X-RAY INSTALLATION /MOUNTING THE TUBE I self have never assemble the x-ray machine before, but I fund it easy spent 5 hours You Just need to know the procedures repair should be..less
50 3 Diagnostic Area Un- Exposed Film screen Cassette storage Film viewing and Diagnosis area (light box) X-ray Procedure ROOM 7 8 Film processing Area (dark room) 1 13 X-ray Requisition Dispatcher and patient Escort Area X-ray tube Bucky tray 4 X-ray ISSN Generator X = University without
51 Engineers at work / installation and adjusting
52 X-RAY TUBE WIRE CONNECTIONS
53 Installation X-ray tube wire connection -With rotating anode connection wires(x2) X-ray tube wire connection small & larger Filaments wire connection wires(4) Ground wire (x1)
54 Connecting the flat panel detector to the HV generator
55 plat panel installation plat panel installation following wire need to be connected Ethernet cable, power supply,cable to the generator data transportation cable once the Flat panel communicated with software there is green light indication
56 Flat panel and generator calibration After each installation you have to align the flat panel and ma calibration follow the manufacture instructions
57 X-ray calibration Ma calibration ma calibration procedure From low dose to the maximum select ma and kvp -~ dose to the maximum ma and measure the ma output by using oscilloscope
58 How can you upgrade your Analogue x- ray machine to DR It is quite simple and cheep Even you x-ray in 15 years old it is possible to upgrade 1. you need a professional camera and Image intensifier to detect x-ray, it package with software DETECTOR CAMERA And small modification on Generator The cost is aloud 7,000~12,000 $ wherever you have a limited funds for new DR system you can upgrade Digital is an engineer responsibility to bring the innovative in your envelopment
59 ISSN X = University without borders for the open society Volume: 4 hat is the best field in biomedical engineering its: because it pays a lot
60 Road what you can deriver
61 Troubleshooting procedure Wait a second!!! it is very important that you fulfill following skills understand the schematic system : image acquisition chain Basic computer communication system : check software, IP address, internet skills?? Electronics or electrical skills?? Do you have test tools such as: voltmeter and oscilloscope
62 RD common error software problem Error sending image to server check the internet connection /speed CPU overheat check the fan / dust, heat dismiss, IP address conflict Wire disconnection check internet protocol check the wire disconnect/ loosen CPU memory crashed Replace memory
63 DR- common error X-ray generator Error on console : consult the service manual board number, error number Power supply error try to hear the burn smell generator gives error :blinking LED generator gives error :blinking LED measure on generator test point easy to find components or wire burned check the board connection / insert property check incoming power supply fuses Identify the defective board see if you can measure the components lever specially power supply board there is chance to repair
64 RD common error x-ray tube Error code. filament open the cup mesure both filament independently in case one filament gone use the second one with limited exposure : filament board / transformer error the anode is not rotating tube over heat check the anode wire for power supply check anode rotation : bearing problem System is normal, but no x-ray emitted check the collimator sliding plate/
65 common error / analogue machines user interface setting film /photo is too blight Auto exposure ( no) / if not increase KVp,mA film /photo is too dark Auto exposure(no) / if not decrease KVp, &ma Patient table is not moving : check the ac motor : coil, fuse, power supply, belt,. no communication with Generator check the wire disconnect/ loosen Automatic expose not function check the expose ionization chamber
66 Troubleshooting principal Precautions! Playing With 120,000Volts~ and 500~ kgs of gear No guessing!! I know you can handle but be careful!!! The role ( KISS)
67 The questions we should ask our self Is there any hospital : private public which need to digitizer they x-ray machine Can we fix the issue for them by transforming the ANALOGUE TO DIGITAL Do you know where to buy camera? do you know how to install?
68 ISSN X = University without borders for the open society Volume: 4 THANK YOU FOR YOUR ATTENTION!!
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General
More informationPage: 1 of 6 Page: 1 of 6
Page: 1 of 6 Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique
More informationX-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
More informationDigital radiography conquers the veterinary world
Digital radiography conquers the veterinary world Author: Dirk De Langhe Increasingly, veterinarians are using medical imaging to diagnose their patients. There is a corresponding tendency towards replacing
More informationDR Retrofit Kit 1417 WL Configuration Integrated PACS
DR Retrofit Kit 1417 WL Configuration Integrated PACS Description: The DR Retrofit Kit 1417WL - Configuration Integrated PACS makes the use of CR Cassettes/Imaging Plates or the use of analogue x-ray films,
More informationCOST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS
COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen
More informationA PACS-Aware DICOM Image Object
Designing and Implementing A PACS-Aware DICOM Image Object For Digital X-ray, Mammography and Intraoral Applications David A. Clunie Quintiles Intelligent Imaging Clear Vision for the Healthcare Industry
More informationX-RAY IMAGING Emerging Digital Technology - CMOS Detectors
Application Note Case Study Technology Primer White Paper X-RAY IMAGING Emerging Digital Technology - CMOS Detectors Image Sensors X-Ray DETECTORS Scanners Image Processing Custom Solutions In all domains
More informationINTRODUCTION. A. Purpose
New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programs Computed Radiography INTRODUCTION A. Purpose This guide describes
More informationPatient Prep Information
Stereotactic Breast Biopsy Patient Prep Information Imaging Services Cannon Memorial Hospital Watauga Medical Center Table Weight Limits for each facility Cannon Memorial Hospital Watauga Medical Center
More informationIntegrated Management & Educational Consultancy
Integrated Management & Educational Consultancy Services MANDEC Radiology Update Seminar for The Dental Team Dr. Richard DeCann & Mr. Tim Reynolds IMECS Radiography Consultants Tel:07855 183117 email:admin@imecs.freeserve.co.uk
More informationIn the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the
In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the discussion on the major components of the x-ray machine. Today
More informationHIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950
HIGH PERFORMANCE MOBILE SURGICAL C-ARM 1K x 1k CCD Digital Camera System H.F. GENERATOR & ROTATING ANODE TUBE WITH DIGITAL WORKSTATION DESCRIPTION: Mobile Surgical C-arm systems are integrated with a triple
More informationDental Radiography Core Subject. Digital Radiography
Dental Radiography Core Subject Digital Radiography Aims: To develop an understanding of the history of digital radiography, the different types of digital x-rays and the advantages and disadvantages of
More informationGraphical displays are generally of two types: vector displays and raster displays. Vector displays
Display technology Graphical displays are generally of two types: vector displays and raster displays. Vector displays Vector displays generally display lines, specified by their endpoints. Vector display
More informationPERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X
DIGITAL X-RAY SYSTEM with ceiling mounted tube support Universal Digital Radiographic System Conventional system, full DR components Best-in-class image quality Flexible connectivity to PACS systems General
More informationI-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit
I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete
More informationUse of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators
Technical Note: 9 Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators 1- Introduction The VALIDATOR, model TN-ID-60, is a compact, and stand-alone dosimetry
More informationThinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,
More informationSOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration
Implementation Page #: Page 1 of 10 Last Reviewed/Update 1. Purpose and Scope The purpose of this document is to describe the Medical Physics and Radiation Safety program at Boston University (BU) and
More informationProduction of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9
Module 9 This module presents information on what X-rays are and how they are produced. Introduction Module 9, Page 2 X-rays are a type of electromagnetic radiation. Other types of electromagnetic radiation
More informationPASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
More informationAN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM
SAMSUNG SMART DIGITAL RADIOGRAPHY 2012 Samsung Electronics All rights reserved. Samsung Electronics reserves the right to modify the design, packaging, specifications and features shown herein, without
More informationElectronic Power Control
Service. Self-Study Programme 210 Electronic Power Control Design and Function With the Electronic Power Control system, the throttle valve is actuated only by an electric motor. This eliminates the need
More informationQUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions
QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES (a) Applicability Quality assurance programs as described in paragraph (c) of this section are recommended for all diagnostic radiology facilities.
More informationX-ray Imaging System. X-Ray Circuit. Principles of Imaging Science II (RAD 120) X-ray Imaging System Circuitry
Principles of Imaging Science II (RAD 120) X-ray Imaging System Circuitry X-ray Imaging System Operating console Set x-ray tube current (quantity) and voltage (quality) Controls line compensation, kvp,
More informationWhat is Radiology and Radiologic Technology?
What is Radiology and Radiologic Technology? Note: Prospective CSI Radiologic Technology students are encouraged to print this document out and study it thoroughly before applying for admission to the
More informationGeorge W. Seeley, Ph.D.*t. Kevin MCNeiII, M.S.t. William J. Dallas, ph.d.*t. Past
RathoGphlcsdexten Displays in radiology: Curnutafiveindoxterms: Past, present, a nd future George W. Seeley, Ph.D.*t Kevin MCNeiII, M.S.t William J. Dallas, ph.d.*t Past. Almost immediately after Wilhelm
More informationProton Therapy. What is proton therapy and how is it used?
Scan for mobile link. Proton Therapy Proton therapy delivers radiation to tumor tissue in a much more confined way than conventional photon therapy thus allowing the radiation oncologist to use a greater
More information53 X-rays and Diagnostic Radiology
Learning Outcomes 53.1 Explain how x-rays are used for diagnostic and therapeutic purposes. 53-2 CHAPTER 53 X-rays and Diagnostic Radiology 53.2 Compare invasive and noninvasive diagnostic procedures.
More informationDisplays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.
Displays Semiconductor Elements 1 Cathode Ray Tube Basic applications Oscilloscope TV Old monitors 2 1 Idea of Electrostatic Deflection 3 Inside an Electrostatic Deflection Cathode Ray Tube Gun creates
More informationU.S. Bureau of Labor Statistics. Radiology Tech
From the: U.S. Bureau of Labor Statistics Radiology Tech What They Do Radiologic technologists (RTs) perform diagnostic imaging examinations, such as x rays, on patients. Duties RTs typically do the following:
More informationPrimary Memory. Input Units CPU (Central Processing Unit)
Basic Concepts of Computer Hardware Primary Memory Input Units CPU (Central Processing Unit) Output Units This model of the typical digital computer is often called the von Neuman compute Programs and
More informationUnderstanding Digital Modalities: System Integration and Use
Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI donaldp@rad.hfh.edu Dicom Digital Imaging and Communications in Medicine Part 3: Information
More informationQUALITY ASSURANCE IN DENTAL RADIOGRAPHY. Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000
QUALITY ASSURANCE IN DENTAL RADIOGRAPHY Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000 Quality Assurance (QA) Ensure consistently adequate diagnostic information whilst keeping doses
More informationPresentation Objective: Benefits to New Employee. Goal for Participants. Benefits to the Administration
Imaging Department Quick Step How to Create and Implement a Rapid Integration Orientation New Employee Orientation builds a bridge between the old job and the new job for better quality in health care
More informationEmbedded Systems in Healthcare. Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008
Embedded Systems in Healthcare Pierre America Healthcare Systems Architecture Philips Research, Eindhoven, the Netherlands November 12, 2008 About the Speaker Working for Philips Research since 1982 Projects
More informationTraining needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology
Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology S Peer 1, R Peer 1, P Torbica 1, W Jaschke 1, E Vaño 2 Innsbruck University
More informationQuality Control of Full Field Digital Mammography Units
Quality Control of Full Field Digital Mammography Units Melissa C. Martin, M.S., FACMP, FACR, FAAPM Melissa@TherapyPhysics.com 310-612-8127 ACMP Annual Meeting Virginia Beach, VA May 2, 2009 History of
More informationRadiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment.
Dictionary Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment. Applicator A device used to hold a radioactive source
More informationComparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis
Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis David Bernard & Steve Ainsworth Dage Precision Industries Abstract Non-destructive testing during the manufacture of
More informationThe Convenient and Compact CR System for Veterinary Practices
The Convenient and Compact CR System for Veterinary Practices Fire CR+ 20 / 40 / 60 / 80 vet with a throughput of 20 to 70 cassettes per hour and the option of a space - saving wall mount The small and
More informationEPEX. The Hologic EPEX General. Direct-to-Digital System for General Radiography. Versatility for a complete range of general radiographic exams
EPEX Direct-to-Digital System for General Radiography Featuring... Versatility for a complete range of general radiographic exams The Hologic EPEX General Radiography System is a direct-to-digital, fully
More informationX-Mind. Instinct for perfection
X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in
More informationPicture Archiving and Communication systems
Picture Archiving and Communication systems (PACS) By: Somayeh nabiuni 1 Major limitations of the conventional radiology practice Wasted time - implying diagnostic results many not be obtained in a timely
More informationComp 410/510. Computer Graphics Spring 2016. Introduction to Graphics Systems
Comp 410/510 Computer Graphics Spring 2016 Introduction to Graphics Systems Computer Graphics Computer graphics deals with all aspects of creating images with a computer Hardware (PC with graphics card)
More informationEconomic Evaluation of Conventional Radiography with Film and Computed Radiography: Applied at BMC
Advances in Computed Tomography, 2012, 1, 23-29 http://dx.doi.org/10.4236/act.2012.13006 Published Online December 2012 (http://www.scirp.org/journal/act) Economic Evaluation of Conventional Radiography
More informationHardware Guide for the Classic and Elite CR Systems. 2011-08-04 PN 9G9637 Version 1.0
Hardware Guide for the Classic and Elite CR Systems 2011-08-04 PN 9G9637 Version 1.0 Use of the Content Carestream Health CR Systems are designed to meet international safety and performance standards.
More informationX-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission
Principles of Imaging Science I (RAD119) X-ray Production & Emission X-ray Production X-rays are produced inside the x-ray tube when high energy projectile electrons from the filament interact with the
More informationThe convenient and compact CR system for veterinary practices
Divario CR-Fvet with dicom PACS DX-R Software CR Systems for the Future The convenient and compact CR system for veterinary practices Divario CR-F20/ F40/ F60/ F80 vet Divario CR-F20/ F40/ F60/ F80 vet
More informationName: Date: Team: Lab Experiment # 3. Focused Grid Positioning Errors. Computed Radiography and Direct Digital Radiography
Name: Date: Team: Lab Experiment # 3 Focused Grid Positioning Errors Computed Radiography and Direct Digital Radiography Purpose This experiment is designed to demonstrate the effect of off-level error,
More informationCOLLEGE ON MEDICAL PHYSICS
COLLEGE ON MEDICAL PHYSICS (30 August - 22 September 2004) Miramare - Trieste, Italy Directors: A. Benini, P. Sprawls and S. Tabakov Local Organizer: L. Bertocchi FINAL PROGRAMME (all lectures were held
More informationStudy the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter
Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter T.M.Taha Radiation Protection Department, Nuclear Research Center, Atomic Energy Authority, Cairo.P.O.13759 Egypt.
More informationBest Practices in Digital Radiography
WHITE PAPER Best Practices in Digital Radiography Tracy L. Herrmann, M.Ed., R.T.(R); Terri L. Fauber, Ed.D., R.T.(R)(M); Julie Gill, Ph.D., R.T.(R)(QM); Colleen Hoffman, R.T.(R)(M)(CT); Denise K. Orth,
More informationCollege on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries
2166-Handout College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries 13 September - 1 October, 2010 Digital Radiography Image Parameters SNR,
More informationCHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging
Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through
More informationHow To Become An Xray Technician
MICHIGAN CIVIL SERVICE COMMISSION JOB SPECIFICATION X-RAY TECHNICIAN JOB DESCRIPTION Employees in this job function as radiological technologists with responsibility for operating X-ray and fluoroscopic
More informationX-ray (Radiography) - Chest
Scan for mobile link. X-ray (Radiography) - Chest What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic x-ray examination. A chest x-ray produces images of
More informationFirst floor, Main Hospital North Services provided 24/7 365 days per year
First floor, Main Hospital North Services provided 24/7 365 days per year General Radiology (X-ray) Fluoroscopy Ultrasound (Sonography) Nuclear Medicine P.E.T. imaging Computed Tomography (CT scan) Magnetic
More informationPrepublication Requirements
Issued Prepublication Requirements The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals
More informationIntroduction to Computers, Anatomy of Computers, Input and Output Devices
LECTURE SCHEDULE 1 Introduction to Computers, Anatomy of Computers, Input and Output Devices In human affairs we have reached a point where the problems that we must solve are no longer solvable without
More informationREGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22
REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ
More informationInfrared Viewers. Manual
Infrared Viewers Manual Contents Introduction 3 How it works 3 IR viewer in comparison with a CCD camera 4 Visualization of infrared laser beam in mid-air 4 Power Density 5 Spectral sensitivity 6 Operation
More informationRadiologic Technology (RAD, CLE) courses are open only to Radiologic Technology majors.
RADIOLOGIC TECHNOLOGY (A.A.S Degree) Director: Prof. Virginia Mishkin, M.S., R.T. (R) (M) (QM) A radiologic technologist is a skilled professional who provides a specialized health care service. This rewarding
More informationicr3600 icr3600m VertX idr Film Digitizers Clarity PACS Innovative Medical Imaging
icr3600 icr3600m VertX idr Film Digitizers Clarity PACS Innovative Medical Imaging Twenty Years of Medical Imaging Innovation The Future of Digital Radiography is at icrco. Founded in 1990 by Stephen Neushul,
More informationDental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral
Dental Radiography X-rays for dental radiography are produced by high voltages of electricity within an x-ray head and come out through a metal tube called a collimator. This ensures the x-rays only come
More informationSECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS
Department of Health and Human services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MAMMOGRAPHY) SECTION
More informationRunning head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1
Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1 Comparison of Amorphous Selenium and Amorphous Silicon Flat-Panel Detectors November 20, 2012 COMPARISON OF FLAT-PANEL DETECTORS 2 Abstract
More informationElements of required physical infrastructures: space, schielding, and patient flow..
Elements of required physical infrastructures: space, schielding, and patient flow.. IAEA Following the IAEA guidelines, adapded by Anna Benini for workshop on Health Technology IUPESM Task Group, Porto
More informationCLINICAL PERFORMANCE OBJECTIVES
CLINICAL PERFORMANCE OBJECTIVES CLINICAL COMPETENCY CLINICAL PERFORMANCE CRITERIA 1. Evaluation of Requisition: Student was able to: a. Identify procedures to be performed b. Recall the patient s age,
More informationDigital Mammography Update: Design and Characteristics of Current Systems
: Design and Characteristics of Current Systems Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington AAPM Annual Meeting 2009 Anaheim,
More informationX-ray (Radiography), Chest
X-ray (Radiography), Chest What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic x-ray examination. A chest x-ray makes images of the heart, lungs, airways,
More informationThe Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.
Radiologic Technologist Overview The Field - Specialty Areas - Preparation - Day in the Life - Earnings - Employment - Career Path Forecast - Professional Organizations The Field Radiologic technologists
More informationMEDICAL EQUIPMENT REPAIRING, 4805
TS-31 June 1974 Federal Wage System Job Grading Standards FEDERAL WAGE SYSTEM JOB GRADING STANDARD FOR MEDICAL EQUIPMENT REPAIRING, 4805 Theodore Roosevelt Building 1900 E Street, NW Washington, DC 20415-8330
More informationTroubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most problems.
More informationPhysics testing of image detectors
Physics testing of image detectors Parameters to test Spatial resolution Contrast resolution Uniformity/geometric distortion Features and Weaknesses of Phantoms for CR/DR System Testing Dose response/signal
More informationXRS-3 X-RAY SOURCE OPERATOR S MANUAL
XRS-3 X-RAY SOURCE OPERATOR S MANUAL CONTENTS ITEM PAGE 1.0 INTRODUCTION... 2 2.0 WARNINGS... 2 EXCLUSION ZONE DIAGRAM. 4 3.0 PHYSICAL DESCRIPTION... 5 3.1 HIGH VOLTAGE PULSER/TUBEHEAD... 5 3.2 BASE...
More informationData. microcat +SPECT
Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for
More information14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
More informationChapter 3: Computer Hardware Components: CPU, Memory, and I/O
Chapter 3: Computer Hardware Components: CPU, Memory, and I/O What is the typical configuration of a computer sold today? The Computer Continuum 1-1 Computer Hardware Components In this chapter: How did
More informationBon Secours St. Mary s School of Medical Imaging Course Descriptions by Semester Class of 2009. CRS 101 Clinical Radiation Science 3
Bon Secours St. Mary s School of Medical Imaging Course Descriptions by Semester Class of 2009 First Year Fall REV.5/07 Credits CRS 101 Clinical Radiation Science 3 A clinical education course designed
More informationCDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
More informationRadiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes
Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes Radiographic Image Production X-ray photons emitted from the x-ray tube interact with the body, exit the patient (exit beam) and interact
More informationCathode Ray Tube. Introduction. Functional principle
Introduction The Cathode Ray Tube or Braun s Tube was invented by the German physicist Karl Ferdinand Braun in 897 and is today used in computer monitors, TV sets and oscilloscope tubes. The path of the
More informationBon Secours St. Mary s Hospital School of Medical Imaging Course Descriptions by Semester 18 Month Program
Bon Secours St. Mary s Hospital School of Medical Imaging Course Descriptions by Semester 18 Month Program First Semester RAD 1101 Patient Care, Ethics, Law and Diversity Credits This 16 week course prepares
More informationOverview. Digital X-ray imaging
Overview Digital X-ray imaging The OR Technology competence group: Your competent partner for digital X-ray imaging Producing digital X-ray technology and developing image management systems for use in
More informationADDIS-Pod2, a turnkey digital podiatry x-ray system w/ APUS hi frequency generator.
podiatric x ray, digital pod, digital detector,... http://addissystem.com/pod2/ 1 of 5 ADDIS-Pod2, a turnkey digital podiatry x-ray system w/ APUS hi frequency generator. Model 128A-S (APUS Included) Shown
More informationIONISING RADIATION. X-rays: benefit and risk
IONISING RADIATION X-rays: benefit and risk Impress Federal Office for Radiation Protection Postfach 10 01 49 D - 38201 Salzgitter Telephone: + 49 (0) 30 18333-0 Fax: + 49 (0) 30 18333-1885 Website: www.bfs.de
More informationCh. 227 ANALYTICAL X-RAY EQUIPMENT 25
Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25 CHAPTER 227. RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT, X-RAY GAUGING EQUIPMENT, ELECTRON MICROSCOPES AND X-RAY CALIBRATION SYSTEMS Sec. 227.1.
More informationBergen Community College Division of Health Professions/ Radiography Program. Course Syllabus and Course of Study for Lecture
Course Information: Course title: Advanced Imaging Equipment and Patient Care Course Code: RAD 184 Credits: 2.0 (30 lecture hours) Pre-requisites: RAD 276 - Imaging Equipment RAD 281 - Radiography II RAD
More informationX-Rays Benefits and Risks. Techniques that use x-rays
X-Rays Benefits and Risks X-rays are a form of electromagnetic radiation, just like light waves and radiowaves. Because X-rays have higher energy than light waves, they can pass through the body. X-rays
More informationNHS Imaging and Radiodiagnostic activity in England. 2012/13 Release. August 2013
NHS Imaging and Radiodiagnostic activity in England 2012/13 Release August 2013 Commentary This National Statistics release covers Imaging and Radiodiagnostic examinations or tests carried out in the NHS
More informationC A M P E P. Standards for Accreditation of Graduate Educational Programs in Medical Physics
Standards for Accreditation of Graduate Educational Programs in Medical Physics Preamble Revised July 2015 Medical Physics is a branch of physics that applies the concepts and principles of physics to
More informationEasy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology
Easy Quality Control with - PTW Equipment Code of Practice - Quality control of X-ray equipment in diagnostic radiology Revised edition October 2010 Code of Practice- Quality control of X-ray equipment
More informationOccupational Profile: Electrical & Electronics Engineering Technician
Occupational Profile: Electrical & Electronics Engineering Technician A competent Electrical & Electronics Engineering Technician should be able to demonstrate the following skills and competences: 1.
More informationVeraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.
Veraview IC5 HD High definition, digital imaging excellence Thinking ahead. Focused on life. Thinking ahead. Focused on life. 2 3 IC5 HD Super High-Speed with High Definition Clarity For dental radiology
More informationRadiation Safety Characteristics of the NOMAD Portable X-ray System
Radiation Safety Characteristics of the NOMAD Portable X-ray System D. Clark Turner 1, Donald K. Kloos 1, Robert Morton 2 1 Aribex, Inc., 754 South 400 East, Orem, UT 84097 USA, www.aribex.com 2 Quality
More informationIntroduction. Stefano Ferrari. Università degli Studi di Milano stefano.ferrari@unimi.it. Elaborazione delle immagini (Image processing I)
Introduction Stefano Ferrari Università degli Studi di Milano stefano.ferrari@unimi.it Elaborazione delle immagini (Image processing I) academic year 2011 2012 Image processing Computer science concerns
More informationDigital Dental X-ray. Midmark Animal Health Products
Digital Dental X-ray Midmark Animal Health Products Disease you can't see... 60% of periodontal disease lies below the gum line, and many issues aren't detectable via probing or visual inspection.* Don't
More informationproper way. Therefore operator training and certification is key in every inspection program to ensure compliance and improve quality and integrity.
SGS NDT Training & Examination Centre Professional Services for Your Safety and Reputation ABOUT NON DESTRUCTIVE TESTING (NDT) About NDT NDT plays a key role in assessing conformity and reliability of
More information