B = Gas sensor 1 F = Gas sensor 2 C = 4-20 ma output scale for sensor 1 G = 4-20 ma output scale for sensor 2 D = Optional on-board relays
|
|
- Alan Watts
- 7 years ago
- Views:
Transcription
1 itrans Base part number ABCDEFG Base price = AUD$ sensor options as listed below. Single or dual on-board or remote toxic, combustible and oxygen sensors with dual 4-20mA(one per sensor) or ModBus RTU outputs. Remote sensors capable of operation up to 200 meters from main transmitter. Operating temperature range 20 C to +50 C (exception: H2S and LEL to -40 C) Example: C21241 =On-board LEL (4-20 ma scale 0-100) and remote mount H 2 S (4-20 ma scale 0-500) with relays A = Sensor 1 Configuration E = Sensor 2 Configuration B = Gas sensor 1 F = Gas sensor 2 C = 4-20 ma output scale for sensor 1 G = 4-20 ma output scale for sensor 2 D = Optional on-board relays A - Sensor 1 Add to Base Price E Sensor 2 Add to Base Price 0 = No sensor 1 = Explosion Proof / On-board No-Charge 1 = Explosion Proof / On-board No-Charge 2 = Explosion Proof / Remote +$ = Explosion Proof / Remote +$ = Non-hazardous Remote/Duct Mount +$ = Non-hazardous Remote/Duct Mount +$ = Explosion Proof / On-board with Splash Guard +$ = Explosion Proof / On-board with Splash Guard +$ = Explosion Proof / Remote with Splash Guard +$ = Explosion Proof / Remote with Splash Guard +$ B - Gas sensor 1 F - Gas sensor 2 1 = Carbon Monoxide (CO) +$ = Carbon Monoxide (CO) +$ = Nitric Oxide (NO) +$ = Nitric Oxide (NO) +$ = Ammonia (NH 3 ) +$ = Ammonia (NH 3 ) +$ = Hydrogen Sulfide (H 2 S) +$ = Hydrogen Sulfide (H 2 S) +$ = Sulfur Dioxide (SO 2 ) +$ = Sulfur Dioxide (SO 2 ) +$ = Nitrogen Dioxide (NO 2 ) +$ = Nitrogen Dioxide (NO 2 ) +$ = Chlorine (Cl 2 ) +$ = Chlorine (Cl 2 ) +$ = Chlorine Dioxide (ClO 2 ) with H 2 S filter +$ = Chlorine Dioxide (ClO 2 ) with H 2 S filter +$ = Hydrogen Cyanide (HCN) +$ = Hydrogen Cyanide (HCN) +$ A = Oxygen (O 2 ) +$ A = Oxygen (O 2 ) +$ B = LEL Infrared (factory Methane calibration) +$ B = LEL Infrared (factory Methane calibration) +$ C = LEL Catalytic Plug-In (factory Pentane calibration) +$ C = LEL Catalytic Plug-In (factory Pentane calibration) +$ D = Carbon Monoxide - Hydrogen Null (CO - H 2 ) +$ D = Carbon Monoxide - Hydrogen Null (CO - H 2 ) +$ F = Hydrogen Chloride (HCl) +$ F = Hydrogen Chloride (HCl) +$ G = LEL Infrared Propane +$ G = LEL Infrared Propane +$ K = Phosphine (PH 3 ) +$ K = Phosphine (PH 3 ) +$ L = Hydrogen (H 2 ) +$ L = Hydrogen (H 2 ) +$ C ma Output Scale for Sensor 1 G ma Output Scale for Sensor 2 0 = No-Charge 0 = No-Charge 1 = No-Charge 1 = No-Charge 2 = No-Charge 2 = No-Charge 3 = 0-50 No-Charge 3 = 0-50 No-Charge 4 = 0-30 No-Charge 4 = 0-30 No-Charge 5 = 0-10 No-Charge 5 = 0-10 No-Charge 6 = 0-2 No-Charge 6 = 0-2 No-Charge 7 = 0-1 No-Charge 7 = 0-1 No-Charge D Standard On-board Relays 1 = With On-board Relays No-Charge O U R M I S S I O N Page 1
2 Replacement Sensors Part Number Base Price LEL Catalytic Sensor $ Oxygen Sensor $ Hydrogen Sulfide Sensor $ Carbon Monoxide Sensor $ Hydrogen Sensor $ Ammonia Sensor $ Hydrogen Chloride Sensor $ Chlorine Sensor $ Nitric Oxide Sensor $ Nitrogen Dioxide Sensor $ Sulfur Dioxide Sensor $ Chlorine Dioxide Sensor $ Phosphine Sensor $ Hydrogen Cyanide Sensor $ Circuit Boards Part Number Base Price Terminal Board, no relays $ Terminal Boards with relays $ Terminal Board, remote housing Consult factory Main electronics module $ Smart Sensor enclosure w/boards $ Accessories Part Number Base Price Calibration wand $ Splash Guard $ Calibration Cup $19.25 O U R M I S S I O N Page 2
3 Remote Sensors Replacement remote sensors are listed below. The part numbers are A, with A being the desired sensor option. A - Sensor Base Price 1 = Carbon Monoxide (CO) $ = Nitric Oxide (NO) $ = Ammonia (NH 3 ) $ = Hydrogen Sulfide (H 2 S) $ = Sulfur Dioxide (SO 2 ) $ = Nitrogen Dioxide (NO 2 ) $ = Chlorine (Cl 2 ) $ = Chlorine Dioxide (ClO 2 ) with H 2 S filter $ = Hydrogen Cyanide (HCN) $ A = Oxygen (O 2 ) $ B = LEL Infrared (factory Methane calibration) $ C = LEL Catalytic Plug-In (factory Pentane calibration) $ D = Carbon Monoxide - Hydrogen Null (CO - H 2 ) $ F = Hydrogen Chloride (HCl) $ G = LEL Infrared Propane $ K = Phosphine (PH 3 ) $ L = Hydrogen (H 2 ) $ O U R M I S S I O N Page 3
4 Digital Transmitters Level Wicks Road Phone: Digital Transmitters are available in the sensor options listed below. The part numbers are A, with A being the desired sensor option. Each transmitter communicates via ModBus RTU over a distance of 200 metres A - Sensor Base Price 1 = Carbon Monoxide (CO) $ = Nitric Oxide (NO) $ = Ammonia (NH 3 ) $ = Hydrogen Sulfide (H 2 S) $ = Sulfur Dioxide (SO 2 ) $ = Nitrogen Dioxide (NO 2 ) $ = Chlorine (Cl 2 ) $ = Chlorine Dioxide (ClO 2 ) with H 2 S filter $ = Hydrogen Cyanide (HCN) $ A = Oxygen (O 2 ) $ B = LEL Infrared (factory Methane calibration) $ C = LEL Catalytic Plug-In (factory Pentane calibration) $ D = Carbon Monoxide - Hydrogen Null (CO - H 2 ) $ F = Hydrogen Chloride (HCl) $ G = LEL Infrared Propane $ K = Phosphine (PH 3 ) $ L = Hydrogen (H 2 ) $ O U R M I S S I O N Page 4
5 Works-In-A-Box Level Wicks Road Phone: Base part number ABCDE Base Price = AUD $ Sensor Options as listed below. All housed in a durable, water and dust resistant Pelican case the base unit consists of AC powered unit with on-board loud A/V alarm, dual WorksAlone 2 electronics modules, quick connect ports for up to 4 sensors and one remote alarm (remote alarm optional). 10 AC power cord, all solder less connectors for up-to 4 remote sensors and one remote alarm. Note: Remote sensor cabling not included Example: A-B = basic unit plus; remote A/V alarm, 2 H2S sensors, 1 O2 sensor and 1 LEL infrared sensor A = A/V Options B = Sensor 1 Options C = Sensor 2 Options Base Price AUD $ Add to Base Price A - A/V Alarm Options 0 = On-Board 103 db Audio/Visual Alarm No-Charge 1 = Remote A/V alarm with 10 cable $ B - Sensor 1 - Includes remote sensor kit - Includes remote splash guard/cal cup - Cable not included D = Sensor 3 Options E = Sensor 4 Options D - Sensor 3 - Includes remote sensor kit - Includes remote splash guard/cal cup - Cable not included 0 = No Sensor Add to Base Price 1 = Carbon Monoxide (CO) $ = Carbon Monoxide (CO) $ = Hydrogen Sulfide (H 2 S) $ = Hydrogen Sulfide (H 2 S) $ = Sulfur Dioxide (SO 2 ) $ = Sulfur Dioxide (SO 2 ) $ = Nitrogen Dioxide (NO 2 ) $ = Nitrogen Dioxide (NO 2 ) $ = Chlorine (Cl 2 ) $ = Chlorine (Cl 2 ) $ = Chlorine Dioxide (ClO 2 ) with H 2 S filter $ = Chlorine Dioxide (ClO 2 ) with H 2 S filter $ A = Oxygen (O 2 ) $ A = Oxygen (O 2 ) $ B = LEL Infrared (Not for use to measure Hydrogen) $ B = LEL Infrared (Not for use to measure Hydrogen) $ C - Sensor 2 - Includes remote sensor kit - Includes remote splash guard/cal cup E - Sensor 4 - Includes remote sensor kit - Includes remote splash guard/cal cup - Cable not included - Cable not included 0 = No Sensor 0 = No Sensor 1 = Carbon Monoxide (CO) $ = Carbon Monoxide (CO) $ = Hydrogen Sulfide (H 2 S) $ = Hydrogen Sulfide (H 2 S) $ = Sulfur Dioxide (SO 2 ) $ = Sulfur Dioxide (SO 2 ) $ = Nitrogen Dioxide (NO 2 ) $ = Nitrogen Dioxide (NO 2 ) $ = Chlorine (Cl 2 ) $ = Chlorine (Cl 2 ) $ = Chlorine Dioxide (ClO 2 ) with H 2 S filter $ = Chlorine Dioxide (ClO 2 ) with H 2 S filter $ A = Oxygen (O 2 ) $ A = Oxygen (O 2 ) $ B = LEL Infrared (Not for use to measure Hydrogen) $ B = LEL Infrared (Not for use to measure Hydrogen) $ O U R M I S S I O N Page 5
6 Replacement Sensors, Options and Accessories for: WorksAlone 2 / Transmitter 2 and Works-in-a-Box Calibration Cups, Splashguards and Filters Calibration Cup (for Toxic, O 2 and Catalytic sensors)...$ Calibration Cup for Infrared sensor...$ Splashguard /Remote Calibration Cup with Filter (for Toxic, O 2 and Catalytic sensors)...$ Note: Maximum flow rate 2500 FPM Replacement filter for $ Splashguard /Remote Calibration Cup with Filter (for Infrared sensors)...$ Replacement filter for $ Bypass/Flow-thru Kit for WA2/T2...$ Mounting Kits Pole Mount Kit for WA2/T2 Main Electronics (designed for 4 pole)...$ STND Duct Mount Kit for WA2/T2 Catalytic/Toxic/Oxygen...$ Note: NEMA 4X enclosure, not approved for hazardous locations Note: Splash Guard/Remote Calibration Cup included in each kit Note: Maximum sensor distance from WA2/T2: LEL 20 feet of 3-conductor cable, sold separately Note: Maximum sensor distance from WA2/T2: Toxic/O feet of 4-conductor cable, sold separately IR Duct Mount Kit for WA2/T2 Infrared...$ Note: As above Remote Enclosure for WA2/T2 and Works-in-a-Box...$ Note: NEMA 4X enclosure rated for Class 1, Division 1, Group B, C, D Note: Splash Guard/Remote Calibration Cup recommended for each remote mount kit Note: Maximum sensor distance from WA2/T2: LEL 20 feet of 3-conductor cable, sold separately Note: Maximum sensor distance from WA2/T2 and Works-in-a-Box: IR/Toxic/O feet of 4-conductor cable, sold separately Remote Sensors for WA2/T2 and Works-in-a-Box CO Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ H 2 S Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ SO 2 Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ NO 2 Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ Cl 2 Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ ClO 2 Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ A O 2 Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ B IR Includes Enclosure, Sensor and Splash Guard /Remote Calibration Cup...$ C LEL Catalytic Sensor Note: As Above for WA2/T2 only...$ O U R M I S S I O N Page 6
7 Replacement Sensors for WA2/T2 and Works-in-a-Box Cl 2 Chlorine Sensor (S/N before 0010)...$ Cl 2 Chlorine Sensor (S/N after 0010)...$ ClO 2 Chlorine Dioxide Sensor...$ CO Carbon Monoxide Sensor...$ H 2 S Hydrogen Sulfide Sensor...$ LEL Combustible Sensor (Hard Wire WAII/TII only)...$ LEL Combustible Sensor (Plug-in Sensor WA2/T2)...$ LEL Combustible Sensor (Infrared)... Consult Factory NO 2 Nitrogen Dioxide Sensor...$ O 2 Oxygen Sensor...$ SO 2 Sulfur Dioxide Sensor...$ Replacement Key Pad/Faceplate for T2...$ Replacement Key Pad/Faceplate for WA2...$ Replacement Electronics Module for T2 (Original Serial Number Required)...$ Replacement Electronics Module for WA2 (Original Serial Number Required)...$ Replacement Key Pad/Faceplate for TII...$ Replacement Key Pad/Faceplate for WAII...$ Replacement Electronics Module WA2...$ Replacement Electronics Module WAII Combustible Sensor...$ Replacement Electronics Module WAII Toxic/Oxygen...$ Replacement Electronics Module T2...$ Replacement Electronics Module TII Combustible Sensor...$ Replacement Electronics Module TII Toxic/Oxygen...$ Smart Sensor Board W2/T2 TOX...$ Smart Sensor Board W2/T2 Oxygen...$ Smart Sensor Board WII/TII TOX...$ Smart Sensor Board WII/TII Oxygen...$ ISC LEL plug in board...$ Replacement Explosion Proof Switch Assembly for WA2/T2, WAII/TII...$ Replacement 1-Amp Fuse for WA2/T2, WAII/TII...$5.50 Replacement Connectors for Works-in-a-Box pin female cable mount connector...$ pin male cable connector for channel 2 (Comes with WIAB)...$ pin female cable mount connector...$ pin male cable connector for channel 1 (Comes with WIAB)...$ pin female cable connector for AC power (Comes with WIAB)...$ pin male connector for external alarm (Comes with WIAB)...$93.50 O U R M I S S I O N Page 7
8 Control/Transmit All Air Aware units are standard with 4-20mA out put and dual 5-amp 30VDC relay out puts All Air Aware units are Modbus equipped All Air Aware units are VDC Part Number Description Price Carbon Monoxide (CO) 0 to 999 ppm $ Nitric Oxide (NO) 0.0 to 99.9 ppm $ Ammonia (NH 3 ) 0 to 200 ppm $ Hydrogen Sulfide (H 2 S) 0 to 999 ppm $ Sulfur Dioxide (SO 2 ) 0.2 to 99.9 ppm $ Nitrogen Dioxide (NO 2 ) 0.2 to 99.9 ppm $ Chlorine (Cl 2 ) 0.2 to 99.9 ppm $ Chlorine Dioxide (ClO 2 ) 0.00 to 1.00 ppm $ Hydrogen Cyanide (HCN) 2 to 30 ppm $ A0300 Oxygen (O 2 ) 0.0 to 30% by volume $ F0300 Hydrogen Chloride (HCl) 0.2 to 30.0 ppm $ K0300 Phosphine (PH 3 ) 0.00 to 1.00 ppm $ L0300 Ethylene Oxide (ETO)* * Consult Industrial Scientific O U R M I S S I O N Page 8
9 Replacement Sensors and Accessories for Air Aware Sensors Price NH 3 Ammonia $ CO Carbon Monoxide $ Cl 2 Chlorine $ ClO 2 Chlorine Dioxide $ ETO Ethylene Oxide Consult ISC HCl Hydrogen Chloride $ HCN Hydrogen Cyanide $ H 2 S Hydrogen Sulphide $ NO Nitric Oxide $ NO 2 Nitrogen Dioxide $ O 2 Oxygen $ PH 3 Phosphine $ SO 2 Sulfur Dioxide $ Accessories Calibration Adapter Assembly $20.35 (Includes adapter, tubing and reducer) Calibration Adapter only $ Optional Vanity Cover $27.50 O U R M I S S I O N Page 9
10 RS5100 Carbon Monoxide Monitor Enclosure: Metal NEMA type, not rated for hazardous service. Range: ppm Carbon Monoxide, Display: 4 digit 1 ½ ultra bright red LED, Relays: two 5 Amp, Power: VAC, Size: 8 x 10 x 4, Operational temperature range: -4ºF to +122ºF (-20ºC to +50ºC) RS5100, Option 0 (no external alarms)...$ RS5100, Option 1 (with red alarm strobe)...$ RS5100, Option 2 (with Banshee siren 103 db at 1 meter)...$ RS5100, Option 3 (with red strobe and Banshee siren)...$ RS5100, Option 4 (with red and amber strobe)...$ RS5100, Option 5 (with red and amber strobe and Banshee siren)...$ RS5100, Option 5 TDR Modified (time delay relays, 3-4 seconds)...$ RS5100, Option 5 (with 2 tone audio alarm and silence button)...$ Replacement Sensors, Options and Accessories for RS Optional Lock Kit...$ Calibration Adaptor...$ Power Cord Kit VAC...$ Replacement Carbon Monoxide Sensor...$ Replacement Manual for RS5100 (supplied with each unit)...$38.50 O U R M I S S I O N Page 10
11 6400 Series Carbon Dioxide Sample Draw Monitor Model 6400/6410 Single Channel Sampling Transmitter includes: (NDIR) CO 2 sensor in NEMA type enclosure, not rated for hazardous service, flow meter, 24 VDC input with 4-20 ma signal output. Operational temperature: 32ºF to 122ºF (0 to 50ºC) CO 2 Model 6410, with display, 0-1% by volume Carbon Dioxide...$ CO 2 Model 6410, with display, 0-5% by volume Carbon Dioxide...$ CO 2 Model 6410, with display, 0-10% by volume Carbon Dioxide...$ CO 2 Model 6410, with display, 0-100% by volume Carbon Dioxide...$ Model 6430/6440 Single Channel Diffusion Transmitter includes: (NDIR) CO 2 sensor in NEMA 4 type enclosure, not rated for hazardous service, 24 VDC input with 4-20 ma signal output. Model 6430 offers 1 relay and on-board audio/visual alarms. Operational temperature: 38 to 104ºF (3 to 40ºC) CO 2 Model 6430, 0-5% by volume Carbon Dioxide, with relay and A/V...$ CO 2 Model 6440, 0-5% by volume Carbon Dioxide...$ Cal adapter for 6430 and $ RS232 cable for 6430 and $ CO 2 Cal Kit 6430/6440 (cable, CO 2, and regulator)...$ H2 cal gas (required with kit)...$82.50 Note: Consult factory for custom ranges O U R M I S S I O N Page 11
12 Optical Flame Detectors Model 660 Ultraviolet Flame Detectors with three-year warranty on parts and labor. Five year warranty on Solar Blind UV sensors. Third Party Approvals. Field configurable relays and sensitivity Standard, Aluminum Housing...$ Standard, Stainless Steel Housing...$ Self-Test, Aluminum Housing...$ Self-Test, Stainless Steel Housing...$ Hi Temp, Standard, Aluminum Housing...$ Hi Temp, Standard, Stainless Steel Housing...$ Hi Temp, Self-Test, Aluminum Housing...$ Hi Temp, Self-Test, Stainless Steel Housing...$ Model 860 Ultraviolet-Infrared Flame Detectors with patented Fire Event Analysis for superior false alarm immunity. Improved advanced Through-The-Lens diagnostic self -test. Three-year warranty on parts and labor. Five-year warranty on Solar Blind UV sensors. Third party approvals. Field configurable relays and sensitivity Standard, Aluminum Housing...$ Standard, Stainless Steel Housing...$ Self-Test, Aluminum Housing...$ Self-Test, Stainless Steel Housing...$ Special Edition, Standard, Aluminum Housing...$ Special Edition, Standard, Stainless Steel Housing...$ Special Edition, Self-Test, Aluminum Housing...$ Special Edition, Self -Test, Stainless Steel Housing...$ Accessories For Model 660 & Swivel Mount 660/860...$ Swivel Mount (Stainless Steel).. $ O U R M I S S I O N Page 12
13 4800 Controller is an analog/digital input/output system controller with remote dial out and access capabilities. Part Number = 4800-ABCDEFGH Base unit consists of Micro-controller with display; modem, AC and phone line surge protection and 24-hour battery back up. A maximum number of 72 channels can be used, however the maximum number of modules (input and output) can not exceed 6 in any combination Example = NEMA 4X enclosure with 16 analog input channels, 8 ModBus RTU input channels, 8 relay contacts A = Base unit E = Controller to controller Support Options B = Analog Input Options F = Relay Options C = Digital Input Options G = Data Logging Options D = ModBus RTU Support Options H = SCADA connection Options A - Base Unit BASE PRICE 1 = NEMA 4X Wall mount enclosure w/display and 24 hour battery back up $ = Sub-Panel Mount w/display and 24 hour battery back up $ = Flush Mount w/display and 24 hour battery back up $ B - Analog Input Options ADD TO BASE E Controller/Controller Support Options ADD TO BASE 0 = None NO-CHARGE 0 = None NO-CHARGE 1 = 1-8 Channel Analog Module $ = Controller to controller communication capable $ = 2-8 Channel Analog Modules (16 channels) $ = 3-8 Channel Analog Modules (24 channels) $ F - Relay Options ADD TO BASE 4 = 4-8 Channel Analog Modules (32 channels) $ = None NO-CHARGE 5 = 5-8 Channel Analog Modules (40 channels) $ = 1-4 Relay Contact Module (4 relays) $ = 6-8 Channel Analog Modules (48 channels) $ = 2-4 Relay Contact Modules (8 relays) $ = 3-4 Relay Contact Modules (12 relays) $ = 4-4 Relay Contact Modules (16 relays) $ C - Digital (Dry Contact) Input Options ADD TO BASE 0 = None NO-CHARGE G - Data Logging Options ADD TO BASE 1 = 4 - Channel Digital Input Module $ = None NO-CHARGE 2 = 8 - Channel Digital Input Module $ = Data Logging $ D - ModBus RTU Input Channels Support Options ADD TO BASE H SCADA connection Options ADD TO BASE 0 = None NO-CHARGE 0 = None NO-CHARGE 1 = 8 Channels of RTU Supported $ = Modbus Slave support via serial, phone or $ = 16 Channels of RTU Supported $ radio modem connection 3 = 24 Channels of RTU Supported $ = 32 Channels of RTU Supported $ = 40 Channels of RTU Supported $ = 48 Channels of RTU Supported $ = 56 Channels of RTU Supported $ = 64 Channels of RTU Supported $ = 72 Channels of RTU Supported $ O U R M I S S I O N Page 13
14 810/820 Controllers Level Wicks Road Phone: The 810/820 Family of low cost controllers offer extreme flexibility and reliability to your fixed system installations. The 810 Digital Controller offers ModBus RTU interfaces for both transmitters as well as interfacing back to a SCADA, PLC, or HMI system. The 820 analog controllers has dual 4-20 ma inputs as well as dual 4-20 ma outputs (pass through). A ModBus RTU interface allows the 820 Controller communication back to larger control systems. Both Controllers offer relay outputs to turn on fans, pumps, or alarms. Part Number and Description Base Price 820 Analog Controller Analog Controller (w/ Relays) $ Digital Controllers channel controller, no relays $ channel controller, no relays $ channel controller, no relays $ channel controller, 16 relays $ channel controller, 16 relays $ channel controller, 16 relays $ O U R M I S S I O N Page 14
15 WIT System The WIT system consists of a single ModBus RTU master control radio that communicates to multiple ModBus RTU slave/repeater radios. The master radio is connected to a controller, PC, or PLC while the slave repeater radios are connected to the ModBus field device. Each slave/repeater radio can communicate to a single ModBus field device, or multiple field devices while acting as a repeater for other radios on the network. These radios seamlessly integrate with the itrans, AirAware, 4800 Controller, and 810/820 Controllers RF900 Master Control radio...$ RF900 Slave/Repeater radio...$ Options and Accessories for WIT Replacement radio transceiver...$ Replacement power supply (din rail mount)...$ Antenna, omni directional...$ O U R M I S S I O N Page 15
16 Remote Sample Pump Designed for use with the WorksAlone II, Transmitter II, and AirAware series. 12 ½ x 10 ½ NEMA type fiberglass enclosure, not rated for hazardous service. 24 VDC or 120 VAC (94-264) operation. One 10 Amp relay contact for low flow alarming. On-board, manual drain, dust filter/water stop. Maximum sample length 100. Operational temperature -4ºF to +122ºF (-20ºC to + 50ºC) VDC Remote Sample Pump...$ VAC Remote Sample Pump...$ Note: The 120 VAC (85-264) version can be used as a 24 VDC power source for the fixed-point monitors and some alarm devices. Consult factory for details. Options and Accessories for Remote Sample Pump Splash Guard for End of Sample Line...$ Replacement Filter for Splash Guard...$ By-pass Kit for 6100/6200 Toxic - Oxygen Transmitters...$ By-pass Kit for all WA2/T2 and LEL versions of 6100/6200 Transmitters...$ Calibration Adaptor for AirAware (adaptor only)...$ Replacement Coalescing Filter Element...$ Stainless Steel Metal Insert for Compression Fitting when plastic tubing...$ Optional 3 Way Valve for Calibration (stainless steel)...$ Optional Flash Arrestors...$ Replacement Diaphragm kit...$ O U R M I S S I O N Page 16
17 Accessories Remote Alarms (NEMA Type Enclosures) ** 24 VDC Audio/Visual Low Power Alarm, Red Lens, 92/110 db (NEMA 4X)...$ ** 24 VDC Audio/Visual Low Power Alarm, Amber Lens, 92/110 db (NEMA 4X)...$ ** 24 VDC Audio/Visual Low Power Alarm, Clear Lens, 92/110 db (NEMA 4X)...$ *** 24 VDC Audio/Visual Remote Alarm with silence switch...$ *** 24 VAC Audio/Visual Remote Alarm with silence switch...$ *** 120 VAC Audio/Visual Remote Alarm with silence switch...$ *24 VDC Audio Remote Alarm without silence switch...$ *120 VAC Audio Remote Alarm without silence switch...$ *24 VDC Audio/Visual Remote Alarm with silence switch...$ *120 VAC Audio/Visual Remote Alarm with silence switch...$ *Audible alarm 100 db at 10. Visual alarm outputs 90 flashes/minute of 300 effective candlepower light. NEMA type enclosure **Audible alarm 92/110 db at 3, 82/100 db at 10. Visual alarm outputs 60 flashes/minute. NEMA type enclosure. -40 O C to + 80 O C *** Audible alarm 80 db, Visual alarm red LED Power Supplies Model 6510 Power Supply, NEMA 4 type VAC to 24 VDC, 50 W output...$ Note: Not rated for hazardous locations Din-mount Power Supply VAC to 24 VDC, 1.5 amp output... $ Power Adapter 120 VAC/24 VDC, 630 ma, (standard with AirAware Monitor version)... $ Power Supply in Explosion Proof Housing VAC to 24 VDC, 2.1 Amp, 50 Watt...$ Uninterruptible Power Supplies (UPS) offer short-term protection for loss of power. Run times very due to applications and load. Consult factory for details on runtimes for your application Model VAC, 140 W Offline-type UPS with internal 24 VDC, 50 W output...$ (Example: Can operate 2 WA2 for approx. 30 minutes. Consult factory for further details) Model VAC, 140 W Offline-type UPS with internal 12 VDC, 50 W output...$ (Example: Can operate 2 WA2 for approx. 30 minutes. Consult factory for further details) Model VAC, 140 W Offline-type UPS, 110 VAC output (non-inductive)...$ (Example: Can operate and 16 sensors for approx.5 minutes. Consult factory for further details) Model W / 1200 W peak Expandable Offline-type UPS, 110 VAC output...$ (Example: Can operate and 16 sensors for approx.1 hr. Consult factory for further details) As 6580 with 2 batteries (can operate and 16 sensors for approx.2.5 hrs)...$ As 6580 with 3 batteries (can operate and 16 sensors for approx.4 hrs)...$ O U R M I S S I O N Page 17
18 Cable Level Wicks Road Phone: Cable, 3-Conductor, 18 AWG, Shielded, sold per foot (OD.23 )...$ Cable, 4-Conductor, 24 AWG, Shielded, sold per foot (OD.34 )...$2.90 Strain Relief Aluminum body, ¾ NPT (not rated for hazardous duty) cable size $ Aluminum body, ¾ NPT (not rated for hazardous duty) cable size $ Aluminum body, ¾ NPT (not rated for hazardous duty) cable size $ Nylon body, ½ NPT (not rated for hazardous duty) cable size $ Nylon nut for , ½ NPT (not rated for hazardous duty)...$ Strain Relief, AirAware...$3.20 Solar Powered Battery Back-up Systems Systems include solar panel/s, battery enclosure with charging circuit, battery/batteries and pipe mounting brackets. Note: Although applications vary, a typical installation would consist of a 3 or 4 dia. schedule 40 pipe installed in an 8 diameter hole to a minimum depth of 24 (or at least 12 below the local frost line). A minimum of 12 of concrete would be poured in the bottom of the hole, while 6 of pipe would remain above grade for mounting the solar panel. The over-all pipe length is determined by local frost line. Note: Application specific information including geographic location of site required before absolute autonomous calculations can be offered. Steel pile, sensors and/or remote alarm not included Watt System with Single Battery (1-2 sensors, one remote alarm, 3-5 days)...$ Watt System with Dual Batteries (2-3 sensors, one remote alarm, 3-5 days)...$ Watt System with Single Battery (1-2 sensors, one remote alarm, 3-5 days)...$ Watt System with Single Battery (1 sensor, one remote alarm, 3-5 days)...$ Spare 12 VDC Battery for Solar Systems...$ Series Remote Display X Model 1200 Single Channel Remote Display (No Audio Alarm)... Consult Factory Model 1220 Single Channel Remote Annunciator Panel (No Display)... Consult Factory X Model 1235 Single Channel Remote Display (With Audio Alarm)... Consult Factory Note: The Remote Display units require an extension number for proper ordering. Please fill in the undefined letter X with the appropriate gas and range from the attached Extension Table. Combination sensors must be listed in alphabetical order. Note: Model 1220 and 1235 must be used in conjunction with a WorksAlone 2 type monitor or controller with on-board relays. Extension Table for Remote Displays B CO (Carbon Monoxide) ppm C CO (Carbon Monoxide) ppm G H 2 S (Hydrogen Sulfide) ppm H H 2 S (Hydrogen Sulfide) ppm N NO 2 (Nitrogen Dioxide) 0-20 ppm S SO 2 (Sulfur Dioxide) 0-10 ppm T SO 2 (Sulfur Dioxide) 0-20 ppm U Oxygen (O 2 ) 0-25% by volume X LEL 0-100% O U R M I S S I O N Page 18
19 In-House Technical Training (National Service Center, North Ryde, Sydney) Repair and Maintenance Training for Instrument Technicians. This training includes theory of operation, troubleshooting techniques and hands-on. Pricing is for training on one instrument type, additional instruments may be added for $ per type. Each session is limited to 5 attendees maximum Repair and Maintenance Training for Instrument Technicians (per day)...$ On-site Start-up and Commissioning On-site start-up and commissioning, includes verification of terminations, initial calibration and personnel training on basic operation and maintenance Airfare and Miscellaneous Travel Expenses...$ billed as actual Note: Multiple days and/ or technicians may be required for large installations On-site Service On-site calibration pricing is a combination of labour, travel time, airfare and calibration gas usage Airfare and Miscellaneous Travel Expenses...$ billed as actual O U R M I S S I O N Page 19
Buckeye Detection Systems Fixed Detection Systems Application Survey
Buckeye Detection Systems Fixed Detection Systems Application Survey Channel Partner Representative : Company Name: Representative: BDS Representative: Client Contact Information : Company Name: Company
More informationP R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationUltima X Series Gas Monitors
Ultima X Series Gas Monitors For continuous monitoring of oxygen, toxics, and combustible gases Now with SIL 2 Certified Products MSA s Ultima X Series Gas Monitors are microprocessor-based transmitters
More informationEXPLORER 4 MULTIPOINT
EXPLORER 4 MULTIPOINT Sampling gas analyser EXPLORER 4 MULTIPOINT is a sampling gas analyser, with 4 gas detection sensors ( LEL,H2S, O2 CO ) reliable and in accordance of the Rules with 15 sampling points
More informationContinuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors
Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject
More informationPortaSens ll G AS DETECTOR
PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor
More informationSingle-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D 4 5062-26-NCL-EN
Single-Gas Detector H 2 S, CO, O 2, SO 2, NH 3, PH 3, Cl 2, ClO 2, NO, NO 2, HCN, ETO, O 3 Long-term solution Compact and affordable, the GasAlert Extreme reliably monitors for any single gas hazard within
More informationAn easy and flexible way to do gas detection.
An easy and flexible way to do gas detection. 24 Plug-and-Play fieldreplaceable sensors including PID and Infrared options Up to 6 gases monitored simultaneously Optional integral sampling pump with strong
More informationRI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
More informationEngineering Specifications XNX Universal Transmitter
Engineering Specifications XNX Universal Transmitter 1.0 General Description: The XNX Universal Transmitter is a comprehensive solution designed to operate in hazardous locations and utilize sensor technologies
More informationENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL. Manual Part Number 80003-035 MCN-389, 01/21/08
PO Box 979 Ann Arbor, MI 48106-0979 ENG 97D STAND-ALONE MANUAL Manual Part Number 80003-035 MCN-389, 01/21/08 Table of Contents 1.0 Introduction...1 1.1 Unpack...1 1.2 Check Order...1 1.3 Serial Numbers...1
More informationSEC 1500 Gas Detector Instruction Manual
SEC 1500 Gas Detector Instruction Manual 1 I. SPECIFICATIONS Table of Contents II. III. IV. GENERAL DESCRIPTION DETAILED DESCRIPTION Enclosure Controls and Indicators Calibration/Reset/Date Switch Optional
More informationMERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE
MERIDIAN UNIVERSAL GAS DETECTOR TECHNICAL DATA PACKAGE Table of Contents 1 Meridian Overview 2 Meridian Specifications 4 Supported Gases 5 Multi Sensor Configurations 6 Technical Drawings 16 Accessories
More informationQ U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure
QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER QUADSCAN II SERIES 7400 ONE TO FOUR CHANNEL RECEIVER Centralizes Monitoring and Alarming for Gas Transmitters and Fire Detectors. The QuadScan II receiver
More informationOperation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family
Operation & Maintenance Manual Electrochemical (EC) Gas Sensor Family For Detection of Oxygen and Toxic Gases Important: Read and understand contents prior to first use. Improper use or operation could
More informationFLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)
FLARE MONITORS Infrared Sensors for Monitoring Smokeless Flares, Pilots, and Flame Intensity FMDS2014 FLARE MONITOR (FM) Monitor smokeless flare combustion efficiency to maximize destruction of hazardous
More informationEnvironmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
More informationSECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS
SECTION 23 90 13 NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS PART 1 - GENERAL 1.01 Section Includes A. Requirements for provision of the Natural Gas (CH4), Carbon Monoxide (CO)
More informationALTAIR 5X Multigas Detector Bid Specification
ALTAIR 5X Multigas Detector Bid Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Size, pumped unit with PID Weight Handling Case material Environmental
More informationSeries B14 Monitor System
Series B14 Monitor System Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New Road, Delph Saddleworth
More informationGlobal Gas Detection and Monitoring Solutions
Global Gas Detection and Monitoring Solutions Portable Gas Detectors Fixed Detectors/Transmitters Fixed System Controllers Accessories Don t Buy Gas Detectors Subscribe to Gas Detection as a Service The
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationRAEGuard EC FGM-13XX
RAEGuard EC FGM-13XX User s Guide P/N 033-4102-000 Rev B May 2007 - READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining,
More informationPolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
More informationResidential & Commercial Alarm Systems by Gross Security, LLC
151 Main Street, Suite, 1, Get these great features with a landline or cellular alarm system from Gross Security, LLC Alarm system prices include installation Base system includes one hour of training
More informationIMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION
Form No. 74-00-4001 S168-527-001 Rev. B IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION Allied Healthcare Products, Inc. s IMPACT alarms are designed
More informationSMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
More informationSection 16935 TELEPHONE AUTOMATIC DIALER SYSTEM
Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular
More informationAmmonia Detection System Codes and Design Specifications
Ammonia Detection System Codes and Design Specifications December 28, 2015 Revision 5 920 N Trade Winds Pkwy Columbia, MO 65201 Ammonia detection system codes and design specifications Following is a discussion
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationABSTRACT INTRODUCTION
Infrared Technology for Fail-To-Safe Hydrocarbon Gas Detection Authors: Dr. Shankar Baliga is Manager of Research & Development at General Monitors. He has a Ph.D. in Physics from Ohio State University
More informationINSTALLATION / OPERATION MANUAL
Critical Environment Technologies MAC Second Generation MINI ANALOG GAS DETECTION CONTROLLER or SELF-CONTAINED SYSTEM INSTALLATION / OPERATION MANUAL REV: C NOV-25-2004 Unit 145, 7391 Vantage Way Delta,
More informationRegulator Options and Accessories
Regulator Options and Accessories Regulator accessories are available separately or mounted on Swagelok regulators. Some accessories limit regulator pressure or temperature ratings. Additional materials,
More informationThe Ambient Air Monitoring System
The Ambient Air Monitoring System 1.0 Introduction: The Ambient Air Monitoring System (AAMS) can measure a range of toxic and flammable gases, particulate matter, meteorological and environmental parameters
More informationBLUE RIBBON CORP. BC001 Birdcage Installation Manual
Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory
More informationDIALER SPECIFICATION VERBATIM MODULAR SERIES VSS
DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS 1. Description and Phone Number Dialing: The dialer shall be a solid state component capable of dialing up to 16 telephone numbers, each up to 60 digits
More informationFire & Security DETECTORS
Fire & Security DETECTORS Smoke Sensitivity 0.98 ~.0%/ft Obscuration Ceiling Spacing 50 foot rating for heat sensor Temperature Range 10ºC to 50ºC Humidity 0 to 95% RH, no condensation or icing Dimensions
More informationThe Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO
The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationSECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
More informationsierra monitor corporation Fire and Gas Detection Systems
sierra monitor corporation Fire and Gas Detection Systems Sierra Monitor Corporation Inspired by technology, driven by safety, designed with passion Information Technology protecting life and property
More informationMSA Fixed Gas & Flame Detection for the Water & Wastewater Industries
MSA Fixed Gas & Flame Detection for the Water & Wastewater Industries A Passion for Safety Every day thousands of municipal and government employees as well as private contractors face many risks working
More informationDIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0
Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm
More informationTriple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
More informationSECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationE-Version SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT
SECTION 15318 - CHLORINATION SYSTEM PART 1 - GENERAL 1.1. SCOPE OF WORK A. Under this item the Contractor shall furnish and install a sodium hypochlorite solution metering system complete with all accessories
More informationCommon parts for OGS/OVS/OTS/OPS 2.X/xx
Common parts for OGS/OVS/OTS/OPS 2.X/xx Part no Description Electronic cabinets 11321 Alarm unit AU2.1 PCB 12035 Alarm unit AU2.0 PCB (This is the former version) 12100 Switch Master PCB 34847 Power Puls
More informationOverview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products
Basic Security 101 Overview Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products Components of an Alarm System Main Control
More informationOVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F
OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.
More informationAutomotive Air Quality Sensors: industrial innovations to protect people s health
Pioneering sensor and detector technology Automotive Air Quality Sensors: industrial innovations to protect people s health COST Action TD1105 3 rd Management Committee Meeting Barcelona, Spain, 21st June
More informationHow Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *
How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work * 1. Oxygen sensor detection principle Most portable or survey instruments used for workplace evaluation of oxygen concentrations
More informationOVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B
OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP
More informationHow To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
More informationUSB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black
USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-
More informationSM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
More informationVentostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
More informationPump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
More informationEX-5175-EC Sensor/Transmitter Manual
PO Box 979 Ann Arbor, MI 48106-0979 www.enmet.com EX-5175-EC Sensor/Transmitter Manual Manual Part Number 80003-099 MCN-13-008, 11/06/13 Table of Contents 1.0 INTRODUCTION... 1 1.1 Unpack... 1 1.2 Check
More informationGasAlertMax XT II H 2 O 2 LEL
Simple operation with pump The rugged GasAlertMax XT II reliably monitors for up to four gas hazards and combines straightforward one-button field operation with an integrated sampling pump. Tamper-proof,
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationBi-Directional Amplifier Systems
Bi-Directional Amplifier Systems Installation and Operation Manual Model Series 850622 EMR CORPORATION 17431 N. 25th Ave. Phoenix, AZ 85023 Emails: sales@emrcorp.com Phone: (623) 581-2875 Toll-Free: (800)
More informationAUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
More informationManual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
More informationMicrocor Wireless Transmitter (MWT)
Rohrback Cosasco Systems, Inc. Microcor Wireless Transmitter (MWT) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments
More informationIndustrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
More informationProduct Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
More informationPIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationSingle Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
More informationFire Alarm System Accessories
Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer
More informationSolar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps
Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric
More informationFMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
More information3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
More informationDrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust
More information2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
More informationThe Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
More informationPowerLogic Sub Meter Display (SMD and SMDOPN)
Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting
More informationComplete SCADA solution for Remote Monitoring and Control
Complete SCADA solution for Remote Monitoring and Control FF-Automation (founded 1976) manufactures AutoLog RTUs, designs and supplies complete automation SCADA solutions for remote monitoring and control
More informationT a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationWIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA
Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set
More informationInterface Level And Point Level Analyzers & Sensors
Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationTechnical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
More informationAnalytical Instruments Smart Analyzer 90 Type SMA
Data Sheet Analytical Instruments Smart Analyzer 90 Type SMA Oxygen Only or Optional Oxygen and Combustibles Rugged Industrial Design Easy Installation and Start-up Highly Accurate Sensors Simplified In-house
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationWIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
More informationUser Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply
User Manual English APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC Tower Uninterruptible Power Supply 990-1587A 12/2005 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent
More informationSINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P
SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P 2 Alarm Levels Bargraph + LED Indication of Gas Concentration Visual and Audible Signalization of Activated Alarm Levels 2 SPDT 5A/250V Output Relays Shock-Proof
More informationAARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS
Wireless - Emergency Alert Systems Easy installation - Wireless Radio System no wires or wiring required Evacuation, Alert & Lockdown all in one system S.O.S Assist - up to 6 unique SOS assistance zone
More informationZlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
More informationTYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output
133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame
More informationCombustible Gas Transmitter 65-2400RK-05
Combustible Gas Transmitter 65-2400RK-05 Overview This detection insert describes the combustible gas transmitter. This insert also describes how to install, start up, maintain, and calibrate the transmitter.
More informationEuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
More information2 & 5-Wire Overfill Sensors
2 & 5-Wire Overfill Sensors Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Universal 2 & 5-Wire Sensor is fully compatible with all our current Sensors and Monitors,
More informationCore Product Guide Gas Leak Detection Solutions for all your building needs
Core Product Guide Gas Leak Detection Solutions for all your building needs Refrigerant Gases Toxic Gases Combustible Gases VOC s Legislation: F Gas Regulation, EH40 Standards: EN378, ASHRAE 15, ASHRAE
More informationO C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
More informationMetering for today s systems
Metering for today s systems The sub-meter gathers data on the building side of the utility company meter. This allows us to break out usage so data can be collected from individual circuits, a single
More information