Contactors - True DC Coil
|
|
- Veronica Knight
- 7 years ago
- Views:
Transcription
1 - True DC Coil Three Pole - Series C7 C7 Non-Reversing, Three Pole With True DC Coil, Series C7 (Open type only) ➊➍ Ratings for Switching C Motors (C2 / C3 / C4) Open Type I e [] uxiliary kw (5 Hz) UL/CS HP (6 Hz) Contacts per ➊ Contactor Ø 3 Ø 4V/ Catalog C-3 C- 23V V 5V 69V 5V 23V 2V 23V 46V 575V NO NC Number /2 / / / / / / Coil Codes ➋ 8.5/ / DC Coil Codes 2D 24D ➌ 48D D Voltage 2V 24V 48V V Coil Terminal Position ll C7 contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. C7 coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering C7 contactors with reversed coils. Price C7-9C-- C7-9C-- 55 C7-2C-- C7-2C-- 2 C7-6C-- C7-6C C7-23C-- C7-23C-- 25 C7-3C-- 29 C7-3C-- 32 C7-3C-- 32 C7-37C-- 35 C7-37C C7-37C C7-43C-- 4 C7-43C C7-43C C7-9C contactor (typical) C7-43C--2 contactor Description: True DC coils have low inrush which allows the use of smaller power supplies. See page 62 for more information. DC and C coils are not interchangeable. C7-9C 43C contactors have increased dimensions to accommodate true DC coils. ll C7 contactors come with reversible coils. 22D 22Vobsolete Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ C Resistive Ratings and UL/CS Continuous Current Ratings may be increased by the use of Lug Kits or Paralleling Links. See C7 ccessories section for applicable information. ➋ Other voltages available, see page 62. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➌ Surge suppressor coil with integrated diode available. Order coil code 24DD and add $42 to list price. To order, change C in catalog number to D. Ex: C7-9C--24DD becomes C7-9D--24DD. Check with customer service representative to determine stock availability. ❹ See pages for limitations on adding auxiliaries to true DC contacts. SSN9 32 Discount Schedule -
2 - True DC Coil Four Pole - Series C7 Non-Reversing, Four Pole With True DC Coil, Series C7 (Open type only) Ratings for Switching C Motors (C2 / C3 / C4) Contact Open Type I e [] kw (5 Hz) UL/CS HP (6 Hz) Configuration, Ø 3 Ø Main Pole 4V C-3 C- 23V V 5V 69V 5V 23V 2V 23V 46V 575V NO NC Catalog Number Price 4 C7-9C-M /2 / /2 3 C7-9C-M C7-9C-M C7-2C-M / /2 3 C7-2C-M C7-2C-M C7-6C-M C7-6C-M C7-6C-M C7-23C-M / C7-23C-M C7-23C-M C7-4C-M / C7-4C-M Coil Codes ➊ DC Coil Codes 2D 24D ➋ 48D D 22D Voltage 2V 24V 48V V 22V obsolete Coil Terminal Position ll C7 contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. C7 coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering C7 contactors with reversed coils. C7-9C contactor (typical) Description: True DC coils have low inrush which allows the use of smaller power supplies. See page 62 for more information. DC and C coils are not interchangeable. C7-9C 4C contactors have increased dimensions to accommodate true DC coils. ll C7 contactors come with reversible coils. C7 SSN9 Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Other voltages available, see page 62. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➋ Surge suppressor coil with integrated diode available. Order coil code 24DD and add $42 to list price. To order, change C in catalog number to D. Ex: C7-9C-M4-24DD becomes C7-9D-M4-24DD. Discount Schedule - 33
3 , DC Coil Reversing Three Pole - Series CU7 Reversing, Three Pole With DC Coil, Series CU7 (Open type only) Ratings for Switching C Motors (C2 / C3 / C4) uxiliary Open Type I e [] kw (5 Hz) UL/CS HP (6 Hz) Contacts per Ø 3 Ø Contactor 4V Catalog C-3 C- 23V V 5V 69V 5V 23V 2V 23V 46V 575V NO NC ➌ Number Price /2 / /2 CU7-9C / /2 CU7-2C CU7-6C /2 5 5 CU7-23C / obsolete 8.5/ / / CU7-3C ➍ CU7-3C CU7-37C-2-89 ➍ CU7-37C CU7-43C ➍ CU7-43C CU7-6D-2-5 ➍ CU7-6D CU7-72D-2-24 ➍ CU7-72D CU7-85D-2-36 ➍ CU7-85D-22-4 CU7-97D-2-7 ➍ CU7-97D NOTE: DC and C coils are not interchangeable. C7-9C 43C contactors have increased dimensions to accommodate true DC coils. C7-6D 97D contactors have a two winding, 3-lead coil with builtin late break auxiliary contact and coil suppression. Refer to page for dimensions. CU7-9C-22 reversing contactor CU7-43C-2 reversing contactor Includes: DC operating mechanism Line side coil terminations Mechanical and electrical Interlock ➌ Reversing power wiring ➊ (using Power Wiring Kit Cat.# CUT7-PW ) Control wiring available; see footnote ➋ C7 SSN9 Coil Codes ➎➏ CU7-9C...43C DC Coil Code CU7-6D...85D DC Coil Code Voltage 2D 2DD 2V 24D ➐ 24DD 24V 48D 48DD 48V D DD V 22D 22DD 22V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ For Reversing without power wiring add suffix -LW to catalog number and deduct the following amount: CU7-9C 23C deduct $ CU7-3C 37C deduct $2 CU7-43C deduct $22 CU7-6D 97D without power wiring not available Ex: CU becomes CU LW. ➋ For control wiring, add suffix -CW to catalog number and add $2. Example: CU becomes CU CW. ➌ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-2) and are used to electrically interlock the contactors. ➍ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➎ Other voltages available, see page 62. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ Coils for CU7-6D 97D reversing contactors include an integrated diode surge suppressor. ➐ Surge suppressor coil with integrated diode available. Order coil code 24DD and add $84 to list price ($42 x two contactors). To order, change C in catalog number to D. Ex: CU7-9C-22-24D becomes CU7-9D-22-24DD. Discount Schedule - 39
4 C7 3-Pole Electrical Data C7-9 C7-2 C7-6 C7-23 C7-3 C7-37 C7-43 C7-6 C7-72 C7-85 C7-97 Resistance and Watt Loss I e C3 Resistance per power pole [mω] Watt Loss - 3 power poles [W] Coil and 3 power poles C [W] DC [W] Coil only C [W] DC [W] Short-Circuit Coordination Max. Fuse or circuit breaker ratings DIN Fuses -gg, gl vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K Type (69V) ➌ [] Type 2 (69V) ➌ [] BS 88 Fuses vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K ➍ Type (69V) ➌ [] ➍ Type 2 (69V) ➌ [] ➍ C7 cul Short-Circuit Ratings Class K, RK, K5, and RK5 Fuses vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K K K K cul Max. Rating (6V) ➋ Type [] Class CC & CS HRCI Fuses vailable Fault Current [] K K K K ~ ~ ~ ~ ~ ~ ~ cul Max. Rating (6V) ➋ Type 2 [] ~ ~ ~ ~ ~ ~ ~ Class J CS & HRCI-J Fuses vailable Fault Current [] K K K K K K K K K K ➍ cul Max. Rating (6V) Type 2 [] ➍ Inverse-Time Circuit Breaker ➊ vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K 5 K 5 K K K K cul Max. Rating 48V ➋ Type [] cul Max. Rating 6V ➋ Type [] ~ ~ ~ ~ Short Time Current Withstand Ratings I cw 6 C s [] Off Time Between Operations [Min.] SSN9 ➊ When used as a Branch Circuit Protection device, NEC defines the maximum rating of an Inverse-time circuit breaker to be sized at 25% of the motor nameplate FL for most applications. ➋ UL Listed Combination. (UL File E485) Per UL58, NEC49 abd CS 22.2 No.4 for contactor and fuses or circuit breaker only. ➌ Per IEC for contactor and fuses only. ➍ To be determined - Test data not available at time of this printing. Discount Schedule - 69
5 C7 3-Pole C7 Electro-Mechanical Data C7-9 C7-2 C7-6 C7-23 C7-3 C7-37 C7-43 C7-6 C7-72 C7-85 C7-97 Service Life Mechanical C [Mil.] DC [Mil.] Electrical C-3 (4V) C [Mil.] Shipping Weights C - C7 [kg] [Lbs.] C -CU7 [kg] [Lbs.] DC - C7 [kg] [Lbs.] DC - CU7 [kg] [Lbs.] Terminations - Power Description One saddleclamp per pole: cross, slotted or Pozidrive No. 2/blade No. 3 screw Dual connection; one saddleclamp and one box lug per pole; cross, slotted or Pozidrive No. 2/blade No. 4 screw Dual connection; two box lugs per pole llen Head: 4mm, 5/32 Wire Wire Wire [WG] [WG] Torque Requirement [Nm] [Lb-in] Terminations - Control Description Combination Screw Head: Cross, Slotted, Pozidrive Coils or 2 Wires [WG] Control Modules or 2 Wires [WG] Torque Requirement [Nm] [Lb-in] Degree of Protection - contactor IP 2LX per IEC 529 and DIN 4 5 (with wires installed) Protection gainst ccidental Contact Safe from touch by fingers and back-of-hand per VDE 6; Part Environmental and General Specifications mbient Temperature Storage C ( F) - [CRI7E Electronic Interface C ( F)] Operation C ( F) Conditioned 5% current reduction after C- at >6 C C ( F) ltitude at installed site 2 meters above sea level per IEC Resistance to Corrosion/Humidity Damp-alternating climate: cyclic to IEC 68-2, 56 cycles Dry heat: IEC 68-2, + C (22 F), relative humidity <5%, 7 days. Damp tropical: IEC 68-2, +4 C (4 F), relative humidity <92%, 56 days. Shock Resistance IEC 68-2: Half sinusoidal shock ms, 3g (in all three directions) Vibration Resistance IEC 68-2: Static > 2g, in normal position no malfunction <5g Pollution Degree 3 Operating Position Refer to Dimension Pages Standards IEC947-/4, EN 6947; UL 58; CS 22.2, No. 4 pprovals CE, UL, CS SSN9 72 Discount Schedule -
6 C7 3-Pole Lug Kit and Paralleling Link Specifications pprovals Conformity to Standards Protection gainst ccidental Contact Terminations C7-P- KN23 / KL23 C7-P-K37 C7-P-K43 C7-P-K85 C7-P-B23 C7-P-B37 UL Listed; CS Certified; C UL58; CS 22.2 No. 4; IEC IP2LX Finger Protection Description Cross, slotted or Pozidrive screw llen Head; 5mm, 3/6 llen Head; 7 mm, 5/32 C7 Wire Size Wire Wire Wire [WG] /...2/...2/ Torque Requirement [Nm] [Lb-in] Coil Data C7-9 C7-2 C7-6 C7-23 C7-3 C7-37 C7-43 C7-6 C7-72 C7-85 C7-97 Voltage Range C: 5Hz, 6Hz, 5/6 Hz Pickup [xu s ] Dropout [xu s ] DC, True & Two Winding Pickup [xu s ].8... (9V coils = ; 24V coils = ) Dropout [xu s ]...6 DC, Electronic Coil (9E 43E) Pickup [xu s ].7.25 Dropout [xu s ].4 Coil Consumption C: 5Hz, 6Hz, 5/6 Hz Pickup [V/W] 7/5 7/5 7/5 7/5 8/6 8/6 3/9 2/ 2/ 2/ 4/24 Hold-in [V/W] 8/2.6 8/2.6 8/2.6 9/3 9/3 9/3 /3.2 6/4.5 6/4.5 6/4.5 24/9 True DC Coils (C7C) Pickup [W] ~ ~ ~ ~ Hold-in [W] ~ ~ ~ ~ Two Winding DC Coils Pickup [W] C7Y & C7D Hold-in [W] DC, Electronic Coil (9E 43E)➋ Pickup vg [W] 2 ~ ~ ~ ~ Pickup Peak [W] Hold-in [W] ~ ~ ~ ~ Operating Times C: 5Hz, 6Hz, 5/6 Hz Pickup [ms] Dropout [ms] with RC Suppressor Dropout [ms] True DC Coils (C7C) Pickup [ms] ~ ~ ~ ~ without Suppression Dropout [ms] ~ ~ ~ ~ with Integrated Suppression Dropout [ms] ~ ~ ~ ~ with External Suppression Dropout [ms] ~ ~ ~ ~ Two Winding DC Coils (C7Y/D) Pickup [ms] with Internal Suppression Dropout [ms] ➊ ➊ ➊ ➊ DC, Electronic Coil (9E 43E) Pickup [ms] ~ ~ ~ ~ Dropout [ms] ~ ~ ~ ~ SSN9 ➊ 22V. ➋ The hold-in demand of the C7-9E 43E is very low but the pick-up demand is approximately ampere at 24 VDC. When sizing (dimensioning) a power supply for applications involving parallel switched contactors then multiply the peak demand by the number of contactors to be simultaneously switched and add to the hold-in demand of all other control circuit burdens, including other contactors, pilot devices, solenoids, etc. Discount Schedule - 73
7 C7 4-pole C7 Electrical Data C7-9-M4 (3; 22) C7-2-M4 (3; 22) C7-6-M4 (3; 22) C7-23-M4 (3;22) C7-4-M22 C7-4-M4 C7-9-M22 C7-9-M4 Resistance and Watt Loss I e C3 Resistance per power pole [mω] Watt Loss - 4 power poles [W] Coil and 4 power poles C [W] DC (true) [W] ~ ~ DC (2 winding) [W] ~ ~ ~ ~ ~ ~ Short Circuit Coordination DIN Fuses -gg, gl vailable Fault Current [] K K K K 5 K 5 K 5 K 5 K Type (69V) ➌ [] Type 2 (69V) ➌ [] BS 88 Fuses vailable Fault Current [] 8 K 8 K 8 K 8 K ~ ~ ~ ~ Type (69V) ➌ [] ~ ~ ~ ~ Type 2 (69V) ➌ [] ~ ~ ~ ~ Class K, RK Fuses vailable Fault Current [] K K K K K K K K Type 2 (6V) ➌ [] cul Short-Circuit Ratings Class K, RK, K5, and RK5 Fuses vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K K K cul Max. Rating (6V) ➋ Type [] Class CC & CS HRCI Fuses vailable Fault Current [] K K K K ~ ~ ~ ~ cul Max. Rating (6V) ➋ Type 2 [] ~ ~ ~ ~ Class J CS & HRCI-J Fuses vailable Fault Current [] K K K K K K K K cul Max. Rating (6V) ➋ Type 2 [] ➍ 7 ➍ 5 ➍ 5 ➍ Inverse-Time Circuit Breaker ➊ vailable Fault Current [] 5 K 5 K 5 K 5 K 5 K 5 K K K cul Max. Rating 48V ➋ Type [] cul Max. Rating 6V ➋ Type [] ~ ~ ~ ~ Short Time Current Withstand Ratings I cw 6 C [] Off Time Between Operations [Min.] ➊ When used as a Branch Circuit Protection device, NEC defines the maximum rating of an Inverse-time circuit breaker to be sized at 25% of the motor nameplate FL for most applications. ➋ UL Listed Combination. (UL File E485) Per UL58, NEC49 abd CS 22.2 No.4 for contactor and fuses or circuit breaker only. ➌ Per IEC for contactor and fuses only. ➍ UL Testing not complete a the time of printing this catalog. SSN9 76 Discount Schedule -
8 C7 4-pole Mechanical Data C7-9-M4 (3; 22) C7-2-M4 (3; 22) C7-6-M4 (3; 22) C7-23-M4 (3; 22) CL7-2 C7-4-M22 C7-4-M4 CL7-3 C7-9-M22 C7-9-M4 CL7-6 Service Life Mechanical C [Mil.] Shipping Weights DC [Mil.] C - C7 [kg] [Lbs.] DC - C7 [kg] Terminations - Power Description [Lbs.] C7 One saddleclamp per pole: cross, slotted or Pozidrive No. 2/blade No. 3 screw Dual connection; one saddleclamp and one box lug per pole; cross, slotted or Pozidrive No. 2/ blade No. 4 screw Dual connection; two box lugs per pole llen Head: 4mm, 5/32 Wire Wire Wire [WG] [WG] Torque Requirement [Nm] [Lb-in] Terminations - Control Description Combination Screw Head: Cross, Slotted, Pozidrive Coils or 2 Wires [WG] Control Modules or 2 Wires [WG] Torque Requirement [Nm] [Lb-in] Degree of Protection - contactor IP 2LX per IEC 529 and DIN 4 5 (with wires installed) Protection gainst ccidental Contact Safe from touch by fingers and back-of-hand per VDE 6; Part SSN9 Environmental and General Specifications mbient Temperature Storage C ( F) - [CRI7E Electronic Interface C ( F)] Operation C ( F) Conditioned 5% current reduction after C- at >6 C C ( F) ltitude at installed site 2 meters above sea level per IEC Resistance to Corrosion/Humidity Damp-alternating climate: cyclic to IEC 68-2, 56 cycles Dry heat: IEC 68-2, + C (22 F), relative humidity <5%, 7 days. Damp tropical: IEC 68-2, +4 C (4 F), relative humidity <92%, 56 days. Shock Resistance IEC 68-2: Half sinusoidal shock ms, 3g (in all three directions) Vibration Resistance IEC 68-2: Static > 2g, in normal position no malfunction <5g Pollution Degree 3 Operating Position Refer to Dimension Pages Standards IEC947-/4, EN 6947; UL 58; CS 22.2, No. 4 pprovals CE, UL, CS Discount Schedule - 77
9 C7 4-Pole C7 Coil Data (C7 4-Pole) C7-9-M4 (3; 22) C7-2-M4 (3; 22) C7-6-M4 (3; 22) C7-23-M4 (3; 22) CL7-2 C7-4-M22 C7-4-M4 CL7-3 C7-9-M22 C7-9-M4 CL7-6 Voltage Range C: 5Hz, 6Hz, 5/6 Hz Pickup [xu s ] Dropout [xu s ] DC, True & Two Winding Pickup [xu s ].8... (9V coils = ; 24V coils = ) Dropout [xu s ]...6 DC, Electronic Coil (9E 4E) Pickup [xu s ].7.25 Dropout [xu s ].4 Coil Consumption C: 5Hz, 6Hz, 5/6 Hz Pickup [V/W] 7/5 7/5 7/5 7/5 3/9 3/9 4/24 4/24 Hold-in [V/W] 8/2.6 8/2.6 8/2.6 9/3 2/3.6 2/3.6 24/9 24/9 True DC Coils (C7C) Pickup [W] ~ ~ Hold-in [W] ~ ~ Two Winding DC Coils Pickup [W] ~ ~ ~ ~ ~ ~ C7Y & C7D Hold-in [W] ~ ~ ~ ~ ~ ~ DC, Electronic Coil (9E 4E)➊ Pickup vg. [W] 2 2 ~ ~ Pickup Peak [W[ Hold-in [W] ~ ~ Operating Times C: 5Hz, 6Hz, 5/6 Hz Pickup [ms] Dropout [ms] with RC Suppressor Dropout [ms] True DC Coils (C7C) Pickup [ms] ~ ~ without Suppression Dropout [ms] ~ ~ with Integrated Suppression Dropout [ms] ~ ~ ~ ~ with External Suppression Dropout [ms] ~ ~ ~ ~ Two Winding DC Coils Pickup [ms] ~ ~ ~ ~ ~ ~ with Internal Suppression Dropout [ms] ~ ~ ~ ~ ~ ~ DC, Electronic Coil (9E 4E) Pickup [ms] ~ ~ Dropout [ms] ~ ~ ➊ The hold-in demand of the C7-9E 43E is very low but the pick-up demand is approximately ampere at 24 VDC. When sizing (dimensioning) a power supply for applications involving parallel switched contactors then multiply the peak demand by the number of contactors to be simultaneously switched and add to the hold-in demand of all other control circuit burdens, including other contactors, pilot devices, solenoids, etc. SSN9 78 Discount Schedule -
10 Dimensions C7 DC Series C7 with DC Coil (True DC and Electronic Coils) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. C7 True DC Electronic DC Catalog Number a b c c c2 ød d d2 C7-9C...C7-6C, CQ7-6C CNX-25C...26C; CN7-2C C7-23C CNX-27C...28C C7-3C...C7-37C; CQ7-37C; CNX-29C; CN7-3C... CN7-37C C7-4C C7-43C, CNX-22C C7-9E...C7-23E C7-3E, C7-37E C7-4E C7-43E (-25/32) (-25/32) (-25/32) 59 (2-2/64) 54 (2-/8) (-25/32) (-25/32) 59 (2-2/64) 54 (2-/8) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) 8 (3-3/6) (4-3/6) 23.5 (4-55/64) 4.5 (5-37/64) 44.5 (5-/6) 44.5 (5-/6) 8.5 (3-/64) 97.5 (4).5 (4-7/64).5 (4-7/64).5 (4) 9 (4-43/64) 3 (5-3/8) 39.5 (5-/2) 4 (5-33/64) 75.5 (3-3/32) 92.6 (3-49/64) 95.5 (3-49/64) 95.5 (3-49/64) 6 (/4) 6 (/4) (7/64) (7/64) (7/64) 6 (/4) (7/64) (7/64) (7/64) (2-3/6) (2-3/6) (2-3/6) (2-3/6) (2-3/6) (2-3/6) (2-3/6) (2-3/6) (2-3/6) (-25/64) 35 (-25/64) 35 (-25/64) (-25/32) (-25/32) 35 (-25/64) 35 (-25/64) (-25/32) (-25/32) Reversing, Capacitor & ccessories (+...) with... Dim. [mm] Dim. [inches] auxiliary contact block-front mounting 2-, or 4-pole c/c + 39 c/c +-37/64 auxiliary contact block- left side mounting -, or 2 pole a + 9 a + 23/64 pneumatic timing module c/c + 58 c/c /64 electronic timing module on coil terminal side b + 24 b + 5/6 mechanical latch c/c + 6 c/c +6 interface module on coil terminal side b + 9 c/c + 2-3/64 Labeling with... label sheet marking tag sheet with clear cover marking tag adapter for V7 Terminals /32 Mounting Position True DC contactors SSN9 Electronic DC contactors 88 Discount Schedule -
11 Coil Data Contactor (Relay) Coil Data ➌ Coil Consumption Coil Consumption Minimum DC Watts C ➊ Recommended Device ➌ Inrush (pick-up) Sealed (holding) Transformer ➍ Inrush Sealed V Watts V Watts V ➋ C8-9 (CS8) C7-9 (CS7) C C C C7-3, CL C C C C7-6, CL C C C7-9 C C C6-5-EI C C6-4-EI C C6-8-EI C6-2-EI C6-25-EI C6-3-EI C6-42-EI C6-63-EI C6-86-EI C C C C C C Starters & Enclosed Prod. TECH SSN9 Control Circuit Transformer Voltage Specifications Factory Factory Wired Connection Voltage Taps vailable Modification Code ➎ Primary Secondary Primary Secondary X /23/46 5 XB /48 2 XC /48 2 XD /6 5/2 XE /48 24 XF /48 24 XG 38 38/4/ /22 XH Must specify tap 5 28/23/46 5 XJ /24 XK /38/277/24/28 24 XL 24 48//4 24/2 XM Must specify tap 24/5 28/23/46 24/5 XN //4 24/2 XO /23/46 24/5 XP /24 24 ➊ 5Hz, 6Hz or 5/6Hz except C7 which is 6Hz. ➋ For C coils. ➌ EI coils are particularly sensitive to the type of control power source provided. Please reference page 2 for details. ➍ The V values shown are the minimum requirement to energize one contactor. For multiple contactors and/or additional control circuit devices (burden) refer to control circuit transformer manufacturer s selection criteria. ➎ Modification codes in Gray are Special Order. Contact an S+S representative. C67
Manual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationRT series Miniature Printed Circuit Board Relays, Sockets and Accessories
s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationType Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More informationInstallation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More information1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationBRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationIndustrial Control Power Transformers
Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationRotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More information3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives
3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationEPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary
225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationCATALOG #250 WWW.DANAHERSPECIALTYPRODUCTS.COM
CATALOG #250 WWW.DANAHERSPECIALTYPRODUCTS.COM TABLE OF CONTENTS Vacuum Control... Low Voltage, Medium Voltage... A NEMA Control - Heavy Duty... TM, 5000... B NEMA Control - General Duty... HP... C Pilot
More informationZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationLow Voltage Fuses For Motor Protection
Code Requirements The NEC or CEC requires that motor branch circuits be protected against overloads and short circuits. Overload protection may be provided by fuses, overload relays or motor thermal protectors.
More informationRelays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules
CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More information3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C
41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers
More informationDirectional Control Valves
echnical Information General he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More information40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationUS Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)
4 NC1 D09-D18 NC1 -D32 US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements) Standards: UL508, CSA C22.2, IEC 60947, and CE Marked Integral DIN Rail & Base Mounting in One Compact
More informationRoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
More informationPLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet 101780_en_02. 1 Description
PLC INERFCE With PD Relay, niversal Version INERFCE Data Sheet 780_en_02 PHOENIX CONC - 03/08 Description PLC-RS /2 relay modules, which can be used universally, comprise 6.2 mm basic terminal blocks and
More information