Product Data and Specifications. Spiral Duct Systems For all HVAC Requirements

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Product Data and Specifications. Spiral Duct Systems For all HVAC Requirements"

Transcription

1 Product Data and Specifications Spiral Duct Systems For all HVAC Requirements

2 STANDARDS FINISHES/ OPTIONS/ SIZES COST RATIO RELATED CONFORMANCE COLORS ACCESSORIES INDEX DATA - Galvanized steel. - Satin coat steel (see below) - Stainless steel (Type 304-2B or 316-2B finish). - Aluminum (Alloy H14) - P.V.S. (Polyvinyl Steel). White is standard. - Other finishes available upon request. - Galvanized steel. - Recommended that exposed systems that are to be painted be fabricated using satin coat material (saves expense of etching galvanized material before painting). - All associated metal fittings. - Top grade U.L.C. sealers and tapes. - Insulation liner with perforated metal inner wall (see Acoustic- Thermal Duct below for liner specifications). - As above - Available 3 to 80 diameter in all common sizes length is standard. Other lengths available upon request. - Gauges conform to and standards. - Available 3 to 80 diameter in all common sizes length is standard. Other lengths available upon request gauge thickness is standard (26 gauge optional) % - 70% - Insulation conforms to U.L.C. 181 and NFPA 90A U.L.C. Listed - As above - All associated metal fittings. - Top grade U.L.C. sealers and tapes. - As above - 250% - For acoustical/thermal data, refer to guides. - U.L.C. Listed for Class A duct system (Nonflammable). - White is standard - All associated metal fittings. - Top grade sealers and tapes as per P.V.S. supplier s recommendations. - Flat P.V.S. sheet also available for custom fabrication e.g. rectangular duct, etc. - Available 3 to 60 diameter in all common sizes length is standard. Other lengths available upon request. - Gauges conform to and standards % - Substantially lower than stainless steel which is commonly used for exhaust systems. Maximum Hydrostatic Pressures Limited by Seam Failure (psi) Dia Ga Ga Ga *Cost Ratio Index based on 100% for Free Flow Spiral Duct with galvanized steel finish. Relative cost of all other duct products are either above or below this figure.

3 FITTINGS Alpha Free Flow manufactures a complete line of fittings in gauges to match the spiral duct application and are designed especially for use with spiral duct. Jobsite conditions may require fittings other than those shown below however any type of fitting is available upon request. The inner shell of Acoustic-Thermal double walled duct fittings are 2 longer at all openings to allow for easy assembly. C Cross D, A, B L=Larger tap diameter + 3 CROSSES CR Cross With Reducer Dimensions to be listed in ordering D, A, B, O L=Larger tap diameter + ( D-O ) + 3 Length of all on center reducing sections are (D-O) with a minimum length of 4 inches. C Double Branch Cross D, A, B, C, E L=A+B (whichever is larger) + 5 or C+E CR Cross With Reducer D, A, B, O L=Larger tap diameter + ( D-O ) + 3 CR Double Branch Cross With Reducer D, A, B, C, E, O L=A+B (whichever is larger) + ( D-O ) + 5 or C+E C Double Branch Cross D, A, B, C, E L=A+B (whichever is larger) + 5 or C+E C Cross D, A, B L=Larger tap diameter + 3 T Double Branch Tee D, A, B L = A+B+5 TT Tangential Tee D, A, L= A+3 TEES TR Tee With Reducer D, A, O L= A+ ( D-O ) + 3 TR Double Branch Tee With Reducer D, A, B, O L = A+ B+ ( D-O ) + 5 T Tee D, A L= A+3

4 ELBOWS E Piece Elbow D R=1.5 x D E Piece Elbow D Center-line radius = 1.5 x D E Elbow D Center-line radius = 1.5 x D E Elbow Dimension to be listed in ordering: D Center-line radius = 1.5 x D 45 LATERALS L Double Lateral D, A, B L = ( A+B) + 5 LR Double Lateral With Reducer D, A, B, O L = (A+B) + ( D-O ) + 5 CLR Double Lateral Cross With Reducer D, A, B, O L = (Larger tap diameter) + ( D-O ) + 3 L Lateral D, A L = A(1.414) + 3 CL Double Lateral Cross D, A, B L = (Larger tap diameter) + 3 LR Lateral With Reducer L = A(1.414) + ( D-O ) + 3 Y Two-Way Y D, A, B MISCELLANEOUS Con T Conical Tee D, A L = A +5 Con TR Conical Tee With Reducer D, A, O L = A + ( D-O ) + 5 Con C Conical Cross D, A, B L = Larger tap diameter + 5 Con CR Conical Cross With Reducer D, A, B, O L = Larger tap diameter + ( D-O ) + 5 CR Equal Change Reducer D, O L = (D-O) imum length SC Pipe Coupling D EC-1 End Cap (for duct) EC-2 End Cap (for fittings) (Specify which is necessary) D SR Straight Side Reducer D, O L = 2(D-O) imum length

5 SPIRAL DUCT SELECTION GUIDE PRODUCT DESCRIPTION RECOMMENDED USES SPECIAL FEATURES Free-flow Spiral Duct Section through strip width - Single wall round duct of helicoidal 4-ply spiral lockseam construction with tightly closed joints to provide smooth interior. - Made from G60 galvanized steel conforming to ASTM A Matching fittings available. - Available insulated with interior metal liner (perforated or unperforated). See Acoustic-Thermal Duct below. - Uses slip type transverse joint or Spirmir Self Sealing System. Companion angle flanged joint recommended for ducts over 60 diameter. institutional projects. - For high negative pressures - For all static pressure classes (1/2 to +10 w.g.). - Specify P.V.S. (Polyvinyl Steel) for under-slab air duct and for corrosive fumes. See below. - For agricultural use. - May also be used for culverts, drains, and dust collection systems. - Round duct can be used to great advantage over rectangular duct due to round duct structural strength and rigidity, important factors in avoiding noise generation, external damage and duct collapse. - Round duct is normally offered in longer lengths and fewer joints, resulting in reduced friction losses, leakage at joints and installation costs. - Available in a wide variety of materials. Multi-rib Spiral Duct Section through strip width - Single wall round duct of helicoidal 4-ply spiral lockseam construction with 3 intermediate standing ribs. Also available 1 or 2 ribs at nominal extra cost. - Made from G60 galvanized steel conforming to ASTM A Matching fittings available. - Available insulated with or without perforated metal liner. - Uses slip type transverse joint. Companion angle flanged joint recommended for ducts over 60 diameter. institution projects wherever a low pressure duct system is required. - Maximum 2 w.g. static positive. - Best quality for least expense in systems that have less than 2 w.g. static pressure. - See round duct features above. Acoustic Thermal Duct Section through strip width - Double walled round duct with fiberglass insulation liner. Consists of outer skin of Free-Flow Spiral Duct as described above, 1 or 2 thickness 3/4 lb. density fiberglass, and standard interior liner of guage G60 galvanized steel Multi- Rib Spiral Duct (as described above) perforated with 3/32 diameter holes staggered 3/16 o.c. (available unperforated for thermal use only). - Low pressure duct (2 w.g. or less) can be supplied with outer skin of Free-Flow spiral duct and interior duct liner insulation only (no interior metal liner) if desired. - Matching fittings available. - Uses slip type transverse joint or Spirmir Self Sealing System. Companion angle flanged joint recommended for ducts over 60 diameter. institutional projects. - For all static pressure classes (1/2 to 10 w.g.). - For maximum noise control and/or thermal efficiency. - See Multi-Rib Spiral Duct above. - Provides high STL (Sound Transmission Loss) through duct walls. - Minimizes noise and sound transmission in duct system. - Minimizes heat loss and provides positive vapour barrier. - Provides double fire protection. - Provides uniform insulation thickness. P.V.S. Spiral Duct (For Under-slab And Corrosive Fumes) Type 1 Smooth Wall Type 2 External Corrugations Section through strip widths - Patented single wall round duct of helicoidal 4-ply spiral lockseam construction with tightly closed joints. - P.V.S. consists of a prime quality G90 galvanized steel with a 4 mil thickness pvc coating fused to both sides using a patented process. - Available unreinforced (Type 1) or with external reinforcing corrugations (Type 2) which increases rigidity of duct by approximately 300%. - Smooth glass-like interior surface of Type 1 (uninreinforced) duct reduces air flow friction to near zero. - Weighs only 1/3 as much as traditional materials such as concrete; reduces labor costs. - Uses slip type transverse joint or Spirmir Self Sealing System. institutional projects. - For all static pressure classes (1/2 to 10 w.g.). - Under-slab air duct. - Ducting for corrosive fumes. - Load limits* - (Type 1-Smooth Wall) 4-8 dia. = 400 lbs. / lin. ft dia. = 800 lbs. / lin. ft. (Type 2 Reinforcing Ribs) 4-8 dia. = 1200 lbs. / lin. ft. - Above weights apply when P.V.S. is installed as recommended with equal compaction in back filling. - Will not rust, chip crack, peel, corrode or produce odors. U.L.C. Tested and labeled. - Light in weight possesses high crushing strength and will not collapse with weight of concrete when poured equally - Can be stacked outdoors without cover, in any weather. - Unaffected by concrete and normal back filling materials. Reagents and test data available upon request. P.V.S. has also passed thousands of hours of accelerated salt spray, humidity cabinet, and water immersion tests with no loss of adhesion or corrosive action. - May be exposed to continuous temperatures ranging from -40 F to 200 F. - Does not need to be encased in concrete, or propped up or tied down. Only a shallow trench is required. No encasement means substantial savings over poured concrete.

6 1080 Meyerside Drive, Mississauga, ON TF: T: F: MEMBER: (Sheet Metal and Air Conditioning Ontario Sheet Metal and Air Handling Group (Spiral Duct Manufacturers Association) Contractors National Association, Inc.

Spiral Duct Specifications

Spiral Duct Specifications Duct Specifications 9707 Williams Road Thonotosassa, FL 33592 Fax (813) 413-8377 Tel (813) 413-8230 Toll free (877) CDS DUCT 237-3828 SINGLE WALL All round spiral duct and fittings shall be manufactured

More information

SPIRAL DUCT & FITTINGS

SPIRAL DUCT & FITTINGS Single-Wall ROUND SPIRAL DUCT & FITTINGS Rev.#4 7/16 2 Single-Wall ROUND SINGLE-WALL ROUND SPIRAL DUCT AND FITTINGS CONSTRUCTION STANDARDS Positive Pressure Gauge selection for galvanized steel (ASTM A

More information

1.02 MATERIAL: A. Metal: Prime furniture steel, free of scales, buckles, or other defects; ASTM A366.

1.02 MATERIAL: A. Metal: Prime furniture steel, free of scales, buckles, or other defects; ASTM A366. 1.01 GENERAL: A. Fume hoods shall be of a "picture frame" airfoil design and construction. Each fume hood superstructure shall provide for safe efficient removal of all fumes, both heavy and light, with

More information

Galvanized Pipe. Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available.

Galvanized Pipe. Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available. Galvanized Pipe Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available. Angle rings are needed to secure connections. See pages

More information

Good, Better, & Best Duct Design. An Overview for ASHRAE Bi State Chapter March 14, 2012

Good, Better, & Best Duct Design. An Overview for ASHRAE Bi State Chapter March 14, 2012 Good, Better, & Best Duct Design An Overview for ASHRAE Bi State Chapter March 14, 2012 Introduction Why Duct Design? How to Design? Design Process (8 steps) Fundamentals Design Methods Introduction Ductwork

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

SAMPLE TEST QUESTIONS INSULATOR - ITA WEBSITE

SAMPLE TEST QUESTIONS INSULATOR - ITA WEBSITE 1 Fibreglass vapour seal insulation is available in sheets 24 in. 48 in. 2 in., with 5 sheets per bundle. How many bundles of insulation are required to cover an area 80 ft. long by 22 ft. wide? A. 19

More information

Thermal Systems Design Guide

Thermal Systems Design Guide THERMAL SYSTEMS Thermal Systems Design Guide Thermalguard & Vapourguard 32 Thermalguard BEHLEN Thermal Assemblies are designed to optimize the thermal performance of any steel structure. Easily combined

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS Perry Fiberglass Products, Inc. FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS PERRY FIBERGLASS Perry Fiberglass Products, Inc. is a leading manufacturer of high

More information

HDPE PIPE. HDPE Pipe Toronto, Edmonton, Saskatoon, Vancouver, Montreal

HDPE PIPE. HDPE Pipe Toronto, Edmonton, Saskatoon, Vancouver, Montreal HDPE PIPE HDPE Pipe Fabco Plastics is the leading Canadian supplier of industrial plastic pipe including HDPE. Our dedicated and knowledgeable sales staff can provide high quality technical information

More information

FINAL December 2012 SECTION 233100 DUCTWORK

FINAL December 2012 SECTION 233100 DUCTWORK SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insula tion shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation

More information

TRICON STEEL-CON. System Specifications

TRICON STEEL-CON. System Specifications TRICON STEEL-CON System Specifications Pipe Size Insulation Thickness Steel Conduit O.D. 1 1½ 6.63 2 1½ 8.63 3 2 10.75 4 2 10.75 6 2 14.00 8 2½ 16.00 10 2½ 18.00 12 2½ 20.00 Based on a minimum 3-6 burial

More information

3. Listed [grease] [dishwasher] [grease and dishwasher] ducts.

3. Listed [grease] [dishwasher] [grease and dishwasher] ducts. SECTION 23 51 00 BREECHINGS, CHIMNEYS, AND STACKS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

Smooth- Products Ltd. TD - Lightweight insulated panel

Smooth- Products Ltd. TD - Lightweight insulated panel 50b TD - Lightweight insulated panel Code TDi20PUblack TD22Ali Description embossed aluminium foil two sides embossed aluminium foil / Aluminium composite Duct Manufacture Smooth-Air Products manufactures

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant

More information

Section 02702 SEWER PIPE INSTALLATION AND TESTING

Section 02702 SEWER PIPE INSTALLATION AND TESTING PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete

More information

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES 4121 N.W. 37 th Street, Lincoln, NE 68524 Telephone (402) 470-2627 Fax (404) 470-2410 www.gtexhaust.com

More information

Gas Distribution and Transportation

Gas Distribution and Transportation Piping System Includes: Pipe Fittings (e.g. elbows, reducers, branch connections, etc.) Flanges, gaskets, bolting Valves Associations involved in generating Codes for piping Design Engineering: ASME ANSI

More information

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

40.68 V33, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Standard Spray Dry Type Concealed Pendent V3301 STANDARD RESPONSE V3302 QUICK RESPONSE

40.68 V33, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Standard Spray Dry Type Concealed Pendent V3301 STANDARD RESPONSE V3302 QUICK RESPONSE SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS The Model V33 Series Dry Type Concealed Pendent Sprinkler with threaded cover assembly and ½" adjustment utilizes stainless steel internal components. The V33

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 816 STEEL PIPE INSTALLATION

San Antonio Water System Standard Specifications for Construction ITEM NO. 816 STEEL PIPE INSTALLATION ITEM NO. 816 STEEL PIPE INSTALLATION 816.1 DESCRIPTION: This item shall consist of steel pipe installation in accordance with these specifications and as directed by the Engineer. 816.2 SUBMITTALS: Contractor

More information

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved

More information

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

Project Name: Reference: Specifier: Date:

Project Name: Reference: Specifier: Date: KALZIP NBS FORMAT (H31) OUTLINE SPECIFICATION Acoustic Purlin Roof Construction 0.20 w/m 2 K U-Value Project Name: Reference: Specifier: Date: H31 METAL PROFILED/FLAT SHEET CLADDING/COVERING To be read

More information

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2)

SECTION THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) SECTION 07 5419 THERMOPLASTIC MEMBRANE ROOFING (Changed by Addendum 2) PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Rigid roof insulation. 2. (Changed by Addendum 1) Mechanically attached single

More information

TABLE OF CONTENTS SECTION 300 STORM SEWER

TABLE OF CONTENTS SECTION 300 STORM SEWER TABLE OF CONTENTS SECTION 300 STORM SEWER Starts on Page 300 GENERAL... 2 301 MATERIALS... 2 302 CONSTRUCTION PROCEDURES... 5 303 TESTING... 5 304 ABANDONMENT OF EXISTING STORM SEWER FACILITIES... 6 305

More information

ELBOWS.

ELBOWS. www.eccomfg.com ECCO INDEX 45 26 Gauge... 54 24 Gauge... 54 22 Gauge... 54 Die Formed Elbow Halves... 56 Die Stamped 1-1/2 Centerline Welded Small End/Small End E-45-1... 57 90 30 Gauge... 52 28 Gauge...

More information

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.

SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010. SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall

More information

GIVENS SPRAY TEC DOWNDRAFT PAINT SPRAY BOOTH

GIVENS SPRAY TEC DOWNDRAFT PAINT SPRAY BOOTH GIVENS SPRAY TEC DOWNDRAFT PAINT SPRAY BOOTH Givens Downdraft Paint Spray Booths are designed to give many years of trouble-free service. Since this booth is pitted, the air flow coming from the ceiling

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

The Kodiak 2400 Seating System by Royal Stewart Ltd.:

The Kodiak 2400 Seating System by Royal Stewart Ltd.: The Kodiak 2400 Seating System by Royal Stewart Ltd.: PART 1 GENERAL 1.1 Description Telescopic Bleacher Seating includes either manually or electrically operated systems of multiple tiered seating rows

More information

C. Trenching, Backfilling, and Compacting: STD SPEC H. Polyethylene Sheet or Tube Encasement: STD SPEC

C. Trenching, Backfilling, and Compacting: STD SPEC H. Polyethylene Sheet or Tube Encasement: STD SPEC STANDARD SPECIFICATION SECTION 15090 BLOW-OFF ASSEMBLIES PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, installation, and testing of blow-off assemblies. Unless otherwise noted on the

More information

Grinnell Grooved Fire Protection Products Grooved Fittings

Grinnell Grooved Fire Protection Products Grooved Fittings Technical Services: Tel: (800) 38-932 / Fax: (800) 79-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description LPCB Vd S The grooved fittings provide an economical

More information

SPECIFICATIONS. DIVISION 7 Thermal and Moisture Protection. Section Architectural Metal Panels. CMPS AP SERIES ALUMINUM PANELS

SPECIFICATIONS. DIVISION 7 Thermal and Moisture Protection. Section Architectural Metal Panels. CMPS AP SERIES ALUMINUM PANELS SPECIFICATIONS DIVISION 7 Thermal and Moisture Protection. Section 07420 Architectural Metal Panels. CMPS AP SERIES ALUMINUM PANELS PART 1 GENERAL 1.1 RELATED WORK.1 Section 04220 Concrete unit masonry.2

More information

Section 402. STORM SEWERS

Section 402. STORM SEWERS 402.02 Section 402. STORM SEWERS 402.01. Description. This work consists of constructing storm sewers of the size and class required, including excavation, bedding, and backfill. 402.02. Materials. Provide

More information

PROPER HANGING OF FIRE SPRINKLER SYSTEMS IFSA. All rights reserved.

PROPER HANGING OF FIRE SPRINKLER SYSTEMS IFSA. All rights reserved. PROPER HANGING OF FIRE SPRINKLER SYSTEMS 2010 IFSA. All rights reserved. 1 HANGING PER NFPA 13 2 Historical developments and basic concepts Hangers Hanger installation Special listed pipe Hangers in earthquake

More information

SECTION 15062 POLYVINYL CHLORIDE GRAVITY SEWER PIPE AND FITTINGS

SECTION 15062 POLYVINYL CHLORIDE GRAVITY SEWER PIPE AND FITTINGS SECTION 15062 POLYVINYL CHLORIDE (PVC) GRAVITY SEWER PIPE AND FITTINGS PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for the manufacture and installation of polyvinyl chloride,

More information

Generic Technical Performance Specification GTS-1653 February 2001 Issue: 01 Revision: 00 Page 1 of 5

Generic Technical Performance Specification GTS-1653 February 2001 Issue: 01 Revision: 00 Page 1 of 5 Issue: 01 Revision: 00 Page 1 of 5 1 ASSEMBLY - GENERAL 1.1 The work of this section includes the provision of all design, labour, materials, equipment and services required to fabricate and install stair

More information

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors. SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION

More information

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary

More information

SECTION 073113 ASPHALT SHINGLES

SECTION 073113 ASPHALT SHINGLES 1320 / Talent Community Center 073113-1 ASPHALT SHINGLES PART 1 GENERAL 1.01 SECTION INCLUDES A. Asphalt shingle roofing. B. SBS roof membrane. SECTION 073113 ASPHALT SHINGLES C. Flexible sheet membranes

More information

SECTION 32 31 13 CHAIN LINK FENCES AND GATES

SECTION 32 31 13 CHAIN LINK FENCES AND GATES SECTION 32 31 13 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Fence framework, fabric, and accessories. 2. Excavation for post bases. 3. Concrete foundation for posts

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains

More information

Florida Building Code, 5 th Edition SHINGLE ROOFING

Florida Building Code, 5 th Edition SHINGLE ROOFING Florida Building Code, 5 th Edition SHINGLE ROOFING Date Issued/Updated: July 6, 2015 This bulletin addresses the current Building Code roofing and re roofing requirements for shingle roofing systems.

More information

.2 Section Waste Management and Disposal..4 Section Testing, Adjusting and Balancing (TAB) of Mechanical Systems.

.2 Section Waste Management and Disposal..4 Section Testing, Adjusting and Balancing (TAB) of Mechanical Systems. Issued 2006/08/01 Section 15072 Vibration Isolation Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 03300 Cast

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced

More information

The City of Winnipeg Section Turtle Island Community Centre Renovation Page 1 of 5

The City of Winnipeg Section Turtle Island Community Centre Renovation Page 1 of 5 Turtle Island Community Centre Renovation Page 1 of 5 Part 1 General 1.1 SECTION INCLUDES.1 Shop fabricated ferrous metal items..2 Shop fabricated aluminum items..3 Steel pipe handrails balusters, and

More information

SEAMLESS WELDED FITTINGS

SEAMLESS WELDED FITTINGS SEAMLESS WELDED FITTINGS WALL THICKNESS NPS Pipe 2 A B K D V E F G O.D. Light SCH SCH STD SCH SCH X-SIG SCH SCH SCH SCH SCH XX NPS Wall 20 0 40 60 80 00 20 40 60 Stg ASA MSS /2.840.08 --- ---.09.09 ---.4.4

More information

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).

Zero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F). PRODUCT BULLETIN Aluminum Polyimide Acrylic (3M 966) PSA First Surface Aluminum Coated Polyimide Tape with Acrylic 3M 966 Adhesive TAPES Sheldahl Brand Materials first surface aluminized polyimide tape

More information

DIVISION 4300 STORM DRAINAGE

DIVISION 4300 STORM DRAINAGE DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES

More information

SECTION 8 AMERICAN. Flanged Pipe

SECTION 8 AMERICAN. Flanged Pipe SECTION 8 AMERICAN Flanged Pipe The principal standards covering Flanged Pipe are ANSI/AWWA C115/A21.15 and ANSI/AWWA C110/A21.10. These and other standards are referenced throughout this Section either

More information

Noise Control. Commercial, Industrial, and Environmental Products and Solutions. www.kineticsnoise.com

Noise Control. Commercial, Industrial, and Environmental Products and Solutions. www.kineticsnoise.com Noise Control Commercial, Industrial, and Environmental Products and Solutions www.kineticsnoise.com Commercial Duct Silencers Kinetics Noise Control offers the design and engineering assistance to integrate

More information

SECTION POLYVINYL CHLORIDE PIPE, AWWA C900/C905

SECTION POLYVINYL CHLORIDE PIPE, AWWA C900/C905 SECTION 02670 POLYVINYL CHLORIDE PIPE, AWWA C900/C905 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Furnish and install AWWA C900 PVC, DR 18 for 4 through 12 size and AWWA C905 PVC, DR 25 for 14

More information

The Visqueen VAPOUR control

The Visqueen VAPOUR control VAPOUR CONTROL LAYERS Visqueen VAPOUR BARRIERS Range suitable for all internal building conditions. Used within roof, wall and floor constructions. Reduces the likelihood of interstitial condensation.

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

SECTION 33 12 19 FIRE HYDRANTS

SECTION 33 12 19 FIRE HYDRANTS SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.

More information

2.3 Adequate space and access shall be provided for all fan locations for maintenance and operations.

2.3 Adequate space and access shall be provided for all fan locations for maintenance and operations. HVAC FANS GENERAL INFORMATION 1.1 This section applies to centrifugal and axial fans. DESIGN REQUIREMENTS 2.1 The Consultant shall include such considerations as duct leakage (expect 5 percent), temperature

More information

INDEX. Sec. No. Items Page Nos.

INDEX. Sec. No. Items Page Nos. INDEX Sec. No. Items Page Nos. 1. Types of Pipe............... MSSP- 2 2. Concrete Pipe............... MSSP- 2 thru MSSP-3 3. ABS and PVC Truss Pipe............... MSSP- 3 4. ABS and PVC Solid Wall Pipe...............

More information

HVAC Duct Construction. Bob Wasilewski Project Manager, Technical Resources SMACNA

HVAC Duct Construction. Bob Wasilewski Project Manager, Technical Resources SMACNA HVAC Duct Construction Bob Wasilewski Project Manager, Technical Resources SMACNA HVAC Duct Construction Standards WHAT? WHY? HOW? Today's Program 1 st 2 nd Edition HVAC-DCS Review Joints and Limitations

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system Design Information Designing Your Dust Collection System There are five simple steps to designing an effective and efficient dust collection system. 1. Draw a floor plan of your shop Important Terms to

More information

1. Galvanized fence framework, fabric, and accessories. 2. Excavation for post bases, and concrete for post footings.

1. Galvanized fence framework, fabric, and accessories. 2. Excavation for post bases, and concrete for post footings. SECTION 32 31 13 CHAIN LINK FENCES PART 1 GENERAL 1.1 SUMMARY A. This Section includes: 1. Galvanized fence framework, fabric, and accessories. 2. Excavation for post bases, and concrete for post footings.

More information

3. ASTM D Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds.

3. ASTM D Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds. SECTION 02623 PART 1 GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment, and incidentals required, and install polyvinyl chloride (PVC) waterline, fittings, service connections and appurtenances

More information

B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories. 1.

B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories. 1. SECTION 07 3113 PART1 GENERAL 1.01 SECTION INCLUDES A. Asphalt shingle roofing. B. Flexible sheet membranes for eave protection, underlayment, and valley protection. C. Associated metal flashings and accessories.

More information

Self-Regulating Heating Tape Installation Manual

Self-Regulating Heating Tape Installation Manual Trace Heating Systems Serving Your Industrial and Domestic Requirements Self-Regulating Heating Tape For installation in safe and hazardous areas Self-Regulating Heating Tape Receipt of Goods After receipt

More information

Heating, Ventilation & Air Conditioning

Heating, Ventilation & Air Conditioning Heating, Ventilation & Air Conditioning Triple Lock Metal non-combustible flexible duct is ideally suited for a wide range of HVAC applications. Flexmaster has proudly supplied superior HVAC products to

More information

CHAPTER 4 INSTALLATION OF PIPE AND TESTING OF PIPE BACKFILL

CHAPTER 4 INSTALLATION OF PIPE AND TESTING OF PIPE BACKFILL CHAPTER 4 INSTALLATION OF PIPE AND TESTING OF PIPE BACKFILL Why talk about pipe in a Soils and Aggregate School? Pipe-soil interaction is critical to successful performance of system Treatment of soils

More information

- STRONGHOLD IRON FENCE PARTS AND MATERIALS SPECIFICATIONS -

- STRONGHOLD IRON FENCE PARTS AND MATERIALS SPECIFICATIONS - - STRONGHOLD IRON FENCE PARTS AND MATERIALS SPECIFICATIONS - PART 1.01: MATERIALS STEEL: All steel material for the fence and gate system shall conform to the requirements of ASTM A- 787 and ASTM A653

More information

2013 Edition. Flanged fittings 30"-64" NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61

2013 Edition. Flanged fittings 30-64 NSF. industrial Applications, water & Wastewater. Certified to ANSI/NSF 61 30"-64" Ductile Iron industrial Applications, water & Wastewater 2 Table of Contents Flanged Fittings for Water 3 Flange Details 5 Flanged Fittings 6 90º and 45º Bend 6 22-1/2º and 11-1/4º Bends 7 Tees

More information

PNEUMATIC CONVEYING COMPONENTS

PNEUMATIC CONVEYING COMPONENTS A H I G H - P E R F O R M A N C E C O M P A N Y PNEUMATIC CONVEYING COMPONENTS TUBING, PIPE, BENDS, COUPLINGS & FITTINGS H-P Products is certified to ISO 9001:2008 Welcome to H-P Products! H-P Products

More information

B. Types of mechanical insulation specified in this section include the following:

B. Types of mechanical insulation specified in this section include the following: SECTION 23 0700 HVAC INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Extent of mechanical insulation required by this section is indicated on drawings and schedules, and by requirements of this section. B.

More information

Steel Deck. A division of Canam Group

Steel Deck. A division of Canam Group Steel Deck A division of Canam Group TABLE OF CONTENTS PAGE OUR SERVICES... 4 NOTES ABOUT LOAD TABLES... 5 P-3615 & P-3606 DIMENSIONS & PHYSICAL PROPERTIES... 6 FACTORED AND SERVICE LOADS... 7 P-2436 &

More information

SaniTite HP Sewer Pipe 750 mm 1500 mm

SaniTite HP Sewer Pipe 750 mm 1500 mm SaniTite HP Sewer Pipe 750 mm 1500 mm sanitite HP SEWER Pipe 750mm 1500mm Extended bell and spigot Certified to CSA B182.13 A new addition to our proven line of pipe products, SaniTite HP (High Performance)

More information

Lorri Grainawi Director of Technical Service Steel Tank Institute STI-SPFA

Lorri Grainawi Director of Technical Service Steel Tank Institute STI-SPFA Lorri Grainawi Director of Technical Service Steel Tank Institute STI-SPFA API - American Petroleum Institute API 12F API 650, Appendix J UL - Underwriters Laboratories UL 142 UL 2085 SwRI - Southwest

More information

Guidelines for Selecting Storage Supplies

Guidelines for Selecting Storage Supplies Guidelines for Selecting Storage Supplies Summary: Choosing appropriate shelving and supplies to store permanent records can be complicated. This handout seeks to simplify the process by providing descriptions

More information

SEE JAMB 3/4" 1 1/2" 14 NOTES: 1. SEE DETAIL 1 FOR KEYNOTE MATERIAL DESCRIPTIONS

SEE JAMB 3/4 1 1/2 14 NOTES: 1. SEE DETAIL 1 FOR KEYNOTE MATERIAL DESCRIPTIONS . FACE OF WALL.. STUD CONSTRUCTION WITH FIBERGLASS BATT INSULATION AND FIBERGLASS FACED EXTERIOR GYPSUM SHEATHING WITH JOINTS SEALED USING -PART POLYURETHANE PRIOR TO INSTALLING FLUID APPLIED WEATHER RESISTANT

More information

Quick response concealed horizontal sidewall sprinkler

Quick response concealed horizontal sidewall sprinkler January 1, 2011 Sprinkler 63a 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK408 is a small solder link and lever spray sprinkler designed for installation on concealed

More information

Acoustic/Thermal Panel Systems for Commercial HVAC Applications

Acoustic/Thermal Panel Systems for Commercial HVAC Applications Acoustic/Thermal Panel Systems for Commercial HVAC Applications We Are Your Sound Solution The success of solving noise problems is dependent upon the characteristics of sound, having an appreciation for

More information

-GAL -DOM -S80SS316 -GALS80

-GAL -DOM -S80SS316 -GALS80 General Information Steel Pipe Fittings & Nipples For desired part number, use the 5-digit Class 150 or Schedule 40 part number and the corresponding suffix. i.e. 1/4 Galvanized 90 Elbow would be 42102-GAL.

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

1036 Parkway Ct. Phone: 770-932-0202 Buford, GA 30518 Fax: 770-945-0041

1036 Parkway Ct. Phone: 770-932-0202 Buford, GA 30518 Fax: 770-945-0041 CONSTRUCTION 1. A. GENERAL 1.A.1. The intent of this specification is to set forth construction and design standards that will result in an installation of modular cabinetry requiring FLUSH OVERLAY CONSTRUCTION.

More information

SECTION 710 GUARDRAIL MATERIALS

SECTION 710 GUARDRAIL MATERIALS 710.08 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SECTION 710 GUARDRAIL MATERIALS 710.01 General. Metal beam

More information

1. Division-5 Section Metal Fabrications for material and welding requirements related to wrought iron fencing.

1. Division-5 Section Metal Fabrications for material and welding requirements related to wrought iron fencing. SECTION 02835 SITE FENCES AND GATES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Used as closure strip at edges of greenscreen panels. Recommended on panel edges adjacent

Used as closure strip at edges of greenscreen panels. Recommended on panel edges adjacent Our Accessory Items list will provide your project with the necessary edge trims, mounting and joining clips, straps, posts, and caps to match your specified finishes with maximum flexibility. ½" leg x

More information

Section 2100-Trenching and Tunneling

Section 2100-Trenching and Tunneling SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial

More information

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

LLOYD INDUSTRIES INC.  DAMPER INSTALLATION INSTRUCTIONS DAMPER Installation and Maintenance Instructions 1-1/2 Hour Rated, UL Classified model 75 fire dampers For use in fire barriers with ratings of less than 3 hours INSPECTION 1. Inspect for shipping damage.

More information

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional

More information

CAGED ALUMINUM ACCESS LADDERS

CAGED ALUMINUM ACCESS LADDERS SECTION 05512 CAGED ALUMINUM ACCESS LADDERS ***** UPNO VR, Inc. manufactures several types of aluminum access ladders. This guide specification section can be used to specify fixed, wall mounted, vertical

More information

NFPA 13 Standard for the Installation of Sprinkler Systems

NFPA 13 Standard for the Installation of Sprinkler Systems Tentative Interim Amendment NFPA 13 Standard for the Installation of Sprinkler Systems 2013 Edition Reference: Chapter 6 TIA 13-2 (SC 12-8-24/TIA Log #1054) Note: Text of the TIA issued and incorporated

More information

Bafl-Sorb Sound Absorbing Ceiling Baffles

Bafl-Sorb Sound Absorbing Ceiling Baffles Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding

More information

Pipe Product Catalog Table of Contents

Pipe Product Catalog Table of Contents Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"

More information

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE

More information

MATERIALS STORM DRAIN PIPE TABLE OF CONTENTS

MATERIALS STORM DRAIN PIPE TABLE OF CONTENTS TABLE OF CONTENTS 1. TYPES OF STORM DRAIN PIPE AND JOINTS... 2 2. MANHOLES, CATCH BASINS AND INLETS BLOCK AND BRICK... 3 3. PRECAST MANHOLES, CATCH BASINS AND INLETS... 4 4. STORM DRAIN STUBS... 4 5. STORM

More information

University of Houston Master Construction Specifications Insert Project Name SECTION HVAC TERMINAL UNITS PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION HVAC TERMINAL UNITS PART 1 - GENERAL SECTION 23 36 00 - HVAC TERMINAL UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00,

More information

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1 ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR

More information