CW2UGE. P/N _A NSF Certified E G F A D P/N_ _A. Technical Data Sheet. November Item Part # Description Wiring Item #

Size: px
Start display at page:

Download "CW2UGE. P/N _A NSF Certified E G F A D P/N_ _A. Technical Data Sheet. November Item Part # Description Wiring Item #"

Transcription

1 C2UE C H E F Technical Data Sheet P/N 0126_A NSF Certified November 2010 H B A D e reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. C Item Part # Description iring Item # FAN ASSEMIES AND THEMOSTATS A. Parent Fan Assembly (1) 0069 Fan Motor, Standard (MO ) Fan Blade (FB.01420) embossing toward motor B. 12 End Compartment Fan Assembly (2) 046 Fan Motor, Standard (MO ) 0323 Fan Blade (FB.40616) embossing away from motor C. 039 Standard Non-Adjustable (3) Defrost Thermostat (CT.4410) Item Part # Description iring Item # LAMPS AND BALLASTS E. Ballast, Electronic lamps (BA.44023) () lamps (BA ) () F. Ballast, Electronic (End Compartment) (6) lamp (BA.4403) Lamp Starter (EP.44101) () H. Fluorescent Lamp () eplace with like fixtures D Optional Adjustable (4) efrigeration Thermostat (CT.4410) Note: Changed items have been underlined HUSSMANN COPOATION BIDETON, MO U.S.A. U.S. & CANADA MEXICO HUSSMANN.COM P/N_0126_A

2 Engineering Plan Views C B / (143) A 32 (13) 40 3 /4 (103) C2U90E C2U90XE Unitized Convertible Island Base ail 29 1 /2 (49) efrig. Outlet 3 / (91) 6 / (149) PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 1 /2 Merchandiser Suction Line (in.) 1 1 / C L 3 1 / (96) aste Outlet & ater Seal Access Area 2 1 /4 (1) 1 1 / (29) 3 / (9) 1 /2 (216) 1 1 /2 (200) Dimensions shown as inches and (mm). ater Seal (12) Front (See Note) (1) 12 / (321) 90 in. 13 in. eneral (A) Case Length (without ends or partitions) 9 (2261) 13 (340) (Each flat end adds 1 1 /2 in. [3 mm] to lineup; each contour end adds in. [12 mm]. Maximum O/S dimension of case front to rear (includes bumper) 1 1 /2 (200) 1 1 /2 (200) (B) End of case to end of compartment 4 1 /4 (1226) 96 1 /4 (14) Length of the end compartment 40 3 /4 (103) 40 3 /4 (103) Front of splashguard to O/S edge of base rail 1 /2 (216) 1 /2 (216) Front edge of case to O/S edge of base rail 12 / (321) 12 / (321) ear of case to O/S edge of front base rail 6 / (149) 6 / (149) idth of base rail 2 1 / (4) 2 1 / (4) Stub-up area between front base rail and splashguard 1 /4 (14) 1 /4 (14) Electrical Service Note: Electrical Field iring connection point Center of Electrical service to O/S edge of front base rail (1) (1) ight end of case to center of knockout (12) (12) Length of electrical raceway 32 / (29) 32 / (29) aste Outlet (C) LH end of case to the center of rear waste outlet 10 1 / (2) 1 / (146) Center of waste outlet to O/S edge of rear base rail 3 / (9) 3 / (9) Left end of case to center of front waste outlet 3 1 / (96) 3 1 / (96) Left edge of end compartment to center of waste outlet 32 (13) 32 (13) ear edge of end compartment to center of waste outlet 3 / (91) 3 / (91) ater Seal ater seal length 11 (29) 11 (29) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (23) ater seal outlet must clear front skid rail. efrigeration Outlet H & LH end of case to center of refrigeration outlets / (143) / (143) Center of refrigeration outlet to O/S edge of front base rail 1 1 / (29) 1 1 / (29) 2 of U.S. & CANADA MEXICO HUSSMANN.COM C2UE Technical Data Sheet

3 Unitized Convertible Island, 2 Display Levels Excel C2UE Unitized Convertible Island C2UE Dimensions shown as inches and (mm). 2 / (61) EFIEATION DATA Note: This data is based on store temperature and humidity that does not exceed F and %.H. C2U C2U 90E 13E Discharge Air ( F) 2 2 Evaporator Air ( F) Unit Sizing ( F) Front of Case 26 (660) 1 /4 (210) (12) (12) 21 (33) 12 / (321) 6 3 / (162) 32 (13) 24 1 / (613) FAN COIL COIL (1) 3 / (9) 1 1/ C L 12 in. Shelf 16 in. Shelf (29) 1/2 (216) 6 / (149) FAN 1 1 /2 (200) 4 (1219) Btu/hr/case* C2U C2U 90E 13E Parallel 10,20 16,440 Conventional 11,660 1,220 *Optional energy efficient motors reduce the refrigeration load of : C2U-90E by 11 Btu/hr/case C2U-13E by 341 Btu/hr/case. DEFOST DATA C2U C2U 90E 13E Frequency (hr) 6 6 Defrost ater (lb/day) (± 1% based on case configuration and product loading). OFFTIME C2U C2U 90E 13E Temp Term ( F) 4 4 Failsafe (minutes) 4 4 ELECTIC O AS Not ecommended Standard Defrost Thermostat Close on rise: close 4 F open 33 F NSF Certification This merchandiser model is manufactured to meet ANSI/NSF (National Sanitation Foundation) Standard # requirements for construction, materials & cleanability. CONVENTIONAL CONTOLS Low Pressure Backup Control C2U C2U 90E 13E CI/CO (Temp F)* 1 / 1 / Indoor Unit Only, Pressure Defrost Termination (Temp F)*4 4 *Use a Temperature Pressure Chart to determine PSI conversions. PHYSICAL DATA Estimated Charge (lb)** C2U-90E 4.0 C2U-13E 6.3 **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. P/N 0126_A 3 of HUSSMANN COPOATION BIDETON, MO U.S.A..HUSSMANN.COM

4 Excel C2UE Unitized Convertible Island Electrical Data 90 in. 13 in. Number of Fans 2 4 Number of Fans Amperes atts 90 in. 13 in. 90 in. 13 in. Evaporator Fan 120V 60Hz Standard V 0Hz Standard 230V 60Hz Export NA NA 230V 0Hz Export NA NA 120V 60Hz Energy Efficient V 60Hz Energy Efficient Cycling Anti-sweat Heaters None Minimum Circuit Ampacity 120V 60Hz Standard V 0Hz Standard NA 230V 60Hz Export NA 230V 0Hz Export NA 120V 60Hz Energy Efficient V 60Hz Energy Efficient NA Maximum Over Current Protection 120V Maximum Over Current Protection 230V V Electric Defrost Heaters None Standard Lighting (T- Fluorescent) 1 ow Canopy Optional Lighting (T- Fluorescent) Additional 1 ow Canopy Additional 2 ow Canopy Optional Shelf Lighting (T- Fluorescent) 1 ows of Shelves ows of Shelves Note 1: All C2 end compartments are equipped with Energy Efficient fan motors as standard. Note 2: C2 end compartments are not available with 2 row canopy lighting due to space constraints. 4 of U.S. & CANADA MEXICO HUSSMANN.COM C2UE Technical Data Sheet

5 Excel C2UE Unitized Convertible Island Product Data C2U90E ecommended Usable Cube 1 (Cu Ft / Case) 43.0 ft 3 /case (1.22 m 3 /case) AI Total Display Area 2 (Sq Ft / Case) ft 2 /case (3.6 m 2 /case) Shelf Area 3 (Sq Ft / Case) 0.40 ft 2 /case (6.4 m 2 /case) C2U13E ecommended Usable Cube 1 (Cu Ft / Case) 6.6 ft 3 /case (1.92m 3 /case) AI Total Display Area 2 (Sq Ft / Case) ft 2 /case (.6 m 2 /case) Shelf Area 3 (Sq Ft / Case) ft 2 /case (10.24m 2 /case) 1 AI efrigerated Volume less shelving and other unusable space: efrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product eference uide. The standard shelf complement for this model is (2) rows of 12-inch shelves and (2) rows of 1-inch shelves. ESTIMATED SHIPPIN EIHT 4 Case C2U-90E C2U-13E lb (kg) 1100 (499) 1600 (26) 4 Actual weights will vary according to optional kits included. P/N 0126_A HUSSMANN COPOATION BIDETON, MO U.S.A..HUSSMANN.COM of

6 Fan iring Offtime Defrost 2 & 4 Fans Front 120V POE BON BAND Fans 1 120V NEUTAL BON BAND ear 120V POE BON BAND Fans 1 BON BAND 2 Fans End Compartment 120V POE Fans 2 BON BAND BON BAND Defrost Termination Thermostat Dark Blue 3 efrigeration Thermostat 4 Light Blue To Condensing } Unit Optional Shelf Lighting 120 V Power 4 Shelf Light Circuits ANIN All components must have mechanical ground, and the merchandiser must be grounded. CICLED NUMBES = PATS LIST ITEM NUMBES rayed components in 13 models only. = ed Y = Yellow = reen = Blue = Black = hite = 120V POE = 120V NEUTAL = FIELD OUND = CASE OUND 6 of U.S. & CANADA MEXICO HUSSMANN.COM C2UE Technical Data Sheet

7 Light Circuits Standard Lighting 1 ow Canopy 120V NEUTAL OANE O TAN BAND 120V POE OANE O TAN BAND Light Switch Optional Lighting 2 ows Canopy 120V NEUTAL OANE O TAN BAND 120V POE OANE O TAN BAND Light Switch ANIN All components must have mechanical ground, and the merchandiser must be grounded. CICLED NUMBES = PATS LIST ITEM NUMBES rayed components in 13 models only. = ed Y = Yellow = reen = Blue = Black = hite = 120V POE = 120V NEUTAL P/N 0126_A HUSSMANN COPOATION BIDETON, MO U.S.A..HUSSMANN.COM of

8 Light Circuits C2U-90E/13E End Compartment Lighting Schematic (Standard canopy lighting and optional shelf lighting are shown) BALLAST MOUNTIN PANEL 6 6 B ANIN All components must have mechanical ground, and the merchandiser must be grounded. CICLED NUMBES = PATS LIST ITEM NUMBES = ed Y = Yellow = reen = Blue = Black = hite = 120V POE = 120V NEUTAL of U.S. & CANADA MEXICO HUSSMANN.COM C2UE Technical Data Sheet

SMG. P/N 0519836_B NSF Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. April 2013. Spanish 0538810 French 0538811

SMG. P/N 0519836_B NSF Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. April 2013. Spanish 0538810 French 0538811 T Stat Bulb Location Technical Data Sheet P/N 0519836_B NSF Certified April 2013 DOE 2012 Energy Efficiency Compliant (Optional Lights) We reserve the right to change or revise specifications and product

More information

P4X-EP. P/N 0463874_K NSF Certified P/N_0463874_K. Technical Data Sheet. June 2012. Item Part # Description Wiring Item #

P4X-EP. P/N 0463874_K NSF Certified P/N_0463874_K. Technical Data Sheet. June 2012. Item Part # Description Wiring Item # P4X-EP Technical Data Sheet P/N 0463874_K NSF Certified June 2012 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes

More information

LTH. Low Temperature. Merchandisers. Installation & Service Manual. P/N 0506146_D December 2010. Keep in store for future reference!

LTH. Low Temperature. Merchandisers. Installation & Service Manual. P/N 0506146_D December 2010. Keep in store for future reference! Merchandisers LTH Low Temperature Merchandisers IMPORTANT Keep in store for future reference! Installation & Service Manual P/N 0506146_D December 2010 P/N0506146_D P/N 0506146_D iii Merchandiser must

More information

DDSS-4MC Medium Temperature Self Contained

DDSS-4MC Medium Temperature Self Contained Æ DDSS-4MC Medium Temperature Self Contained Open Vertical Merchandisers DDSS-4MC IMPORTANT Keep in store for future reference! MANUAL - I/O SC DDSS Installation & Operation Manual June 2016 Spanish 0531283

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

EcoShine II Plus LEDs

EcoShine II Plus LEDs EcoShine II Plus LEDs for Service, Self-Service and Specialty Merchandisers Shelf, ail and Canopy Upgrade Installation Manual P/N 0524983_C September 2014 MANUAL- KIT INSTALLATION ECOSHINE II SEVICE, SELF-SEVICE

More information

REFRIGERATION. Standard Features & Accessories. Model Options. Freestanding 36 W. French-Door. Models include. VCFF136* Professional.

REFRIGERATION. Standard Features & Accessories. Model Options. Freestanding 36 W. French-Door. Models include. VCFF136* Professional. Standard Features & Accessories Models include Total capacity 19.6 cu. ft. (545.7 L) 72 H./D. Cabinet depth design (D. side panels) integrates with surrounding cabinetry fit for replacement of most existing

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

SCCG50 & SCCP50 Service Parts

SCCG50 & SCCP50 Service Parts SCCG0 & SCCP0 Service Parts This is the illustrated parts list for the SCCG0M and the SCCP0M esidential Ice Machines hen ordering a service part, always refer to the complete model number of the equipment

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060 4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE

More information

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND SERVICE MANUAL CI8100 IMI Wilshire, Inc. IMI WILSHIRE, INC. COUNTER INTELLIGENCE BEVERAGE SYSTEM CI8100 INSTALLATION AND SERVICE MANUAL 1993 IMI Wilshire, Inc. TABLE OF CONTENTS CI8100 IMI Wilshire, Inc. SECTION I CI8100

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

FROZEN FOOD/ ICE CREAM MODEL: RZH INSTALLATION & OPERATION HANDBOOK. P067076B Rev. 5 11/08 COMPONENT

FROZEN FOOD/ ICE CREAM MODEL: RZH INSTALLATION & OPERATION HANDBOOK. P067076B Rev. 5 11/08 COMPONENT FROZEN FOOD/ ICE CREAM C A S E S MODEL: RZH INSTALLATION & OPERATION HANDBOOK COMPONENT P067076B Rev. 5 11/08 Welcome to the Hill PHOENIX display case family. We re very pleased you joined us. This installation

More information

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST 12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

BMG/TMG -27, 48, 52, 74, 80 LAE CONTROLLER Installation & Operations Manual

BMG/TMG -27, 48, 52, 74, 80 LAE CONTROLLER Installation & Operations Manual BMG/TMG -27, 48, 52, 74, 80 LAE CONTROLLER Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS 38652 Phone: (800) 684-8988 PN 075-90000 Rev 4-26-11 1 2 TABLE OF CONTENTS

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Troubleshooting Your Refrigerator

Troubleshooting Your Refrigerator Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

GCS16 GCS20 WARNING CAUTION

GCS16 GCS20 WARNING CAUTION Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat

More information

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the

More information

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart Overview HP Managed and Unmanaged Notebook Charging Carts Models HP 20-Notebook Charging Cart HP 30-Notebook Charging Cart HP 20-Notebook Managed Charging Cart HP 30-Notebook Managed Charging Cart QL488AA#ABA

More information

ILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO.

ILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO. XTREME ICE MAKER (0 SERIES) MODEL NO. 00 00 00 00 00 00 0 XTREME ICE MAKER (0 SERIES) FIGURE. GENERAL ASSEMBLY (AIR CONDENSER SHOWN) 00 Screw TC - HXWS 00000 Screw TC - HXWS 0 (Marine) 0000 Grommet Nut

More information

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 3 05 Litho In U.S.A. (cre) 1 Part No. Rev.A OVEN PARTS 1 Literature Parts 4455994 Installation Instructions Use & Care Guide 8300346 Microwave

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

NSN 4120-01-21 4-3692

NSN 4120-01-21 4-3692 *TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21

More information

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

UV100A Ultraviolet Air Treatment System

UV100A Ultraviolet Air Treatment System UV100A Ultraviolet Air Treatment System INSTALLATION INSTRUCTIONS APPLICATION When installed in forced air heating and cooling systems, the UV100A Ultraviolet Air Treatment System kills airborne microorganism

More information

Installation Instructions

Installation Instructions CNPVU CNRVU Uncased Coils Upflow - Downflow Heating - Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

Customized Assessment Blueprint

Customized Assessment Blueprint Customized Assessment Blueprint HVAC Installer Basic - Test Codes: 7906 and 7796 Measuring What Matters Competencies and Skills Tested in this Assessment: HVAC Theory Heat Theory and Refrigeration HVAC

More information

Switches & Pilot Devices

Switches & Pilot Devices Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart Overview Models HP 20-Notebook Charging Cart HP 30-Notebook Charging Cart HP 20-Notebook Managed Charging Cart HP 30-Notebook Managed Charging Cart QL488AA#ABA H4F31AA#ABA QL489AA#ABA QL490AA#ABA Introduction

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Liebert DS Thermal Management Unit

Liebert DS Thermal Management Unit Liebert DS Thermal Management Unit System Design Manual - 28-105kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL Economizer Coil, Dual-Cool DX with Secondary

More information

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08 Air Volume Requirement Air conditioning systems are engineered with a specific amount of indoor air passing across the surface of the evaporator coil. The amount of air is measured in cubic feet per minute.

More information

French Door Refrigerator E23BC78IPS professional series

French Door Refrigerator E23BC78IPS professional series French Door Refrigerator E23BC78IPS professional series 23 CU. FT. COUNTER-DEPTH FRENCH DOOR REFRIGERATOR Custom Temp Drawer Enjoy the ultimate in versatility with 9 preset selections including White/Sparkling

More information

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30, 2015 -

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30, 2015 - Skills Canada National Competition Instructions and Competition Details / Post - Secondary May 27-30, 2015 - Saskatoon 1. Test Project Details This project is designed to test the range of skills used

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA CONTROL & OPERATING INSTRUCTIONS The controls on your new

More information

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 7 03 Litho In U.S.A. (cre) 1 Part No. OVEN PARTS NOTE: The screws and nuts required to attach a part are listed immediately following that part.

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

How To Understand Evaporator

How To Understand Evaporator SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

TEMPERATURE CONTROLS/ THERMOMETER/TIMERS

TEMPERATURE CONTROLS/ THERMOMETER/TIMERS TEMPERATURE CONTROLS/ THERMOMETER/TIMERS 117 118 NOTES TEMPERATURE CONTROLS/ THERMOMETER/TIMERS Temperature Control Repairs 119 HOW TO DIAGNOSE STEP 1 - Control must operate within its pre-calibrated range

More information

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES. QUIET-ONE Environmental Products 2000 Kickspace Heater Series Models: KS 2004, KS 2006 KS 2008, KS 2010 INSTALLATION OPERATING MAINTENANCE Please read these instructions thoroughly before beginning your

More information

MAYTAG MFD2560HEB NACIONAL E IMPORTACIÓN CABINET BACK

MAYTAG MFD2560HEB NACIONAL E IMPORTACIÓN CABINET BACK CABINET BACK 1 CABINET BACK 1 12575101ED BACK, MACH COMP 2 67004098 COVER, WATER VALVE 3 M0238616 SCREW, SM 4 M0251015 SCREW 5 B5759649 GASKET, MC BACK 6 67004092 BLOCK, FILTER 7 M0211018 SCREW, SM 8 67003729

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Commercial Refrigeration Temperature and Defrost Controls

Commercial Refrigeration Temperature and Defrost Controls Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys

More information

Duct Free Split Air ConditionerS

Duct Free Split Air ConditionerS Duct Free Split Air ConditionerS Quality, convenience, efficiency, quiet operation More stylish than a room air conditioner, gives you back your window space, and quieter than conventional central air

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX ZANUSSI S.p.A. Publication no. Spares Operations Italy 599 35 61-04 Corso Lino Zanussi, 30 021218 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434 394096

More information

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N 89104461

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N 89104461 PROAIR Air Conditioner CR29 Model INSTRUCTION MANUAL Rev. F 2015 Pentair Equipment Protection P/N 89104461 89104461 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Service & Parts Manual

Service & Parts Manual Service & Parts Manual Portable Air Conditioner Models P09B and P2B ( Serial Number Beginning with an "A") Models P09B-A and P2B-A Portable Air conditioner-200 Svc Parts (4-200) Service Points and Flow

More information

Integral Kit Instructions

Integral Kit Instructions Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has

More information

Installer s Guide 18-AH39D1-13

Installer s Guide 18-AH39D1-13 18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

RF Maestro Local Controls

RF Maestro Local Controls RF Maestro Local Controls Wireless Series Local Controls RF Link-8.1 Designer-Style L o c a l c o n t r o l s RF Maestro local controls function much like standard dimmers and switches, but can be controlled

More information

BEVERAGE-AIR PARTS MANUAL FOR DD/BB/BM/GF/MS ALL PURPOSE COLD DIRECT DRAW BACK BAR BAR MOBILE GLASS FROSTER MIXED STORAGE 115V/60HZ 220V/50HZ

BEVERAGE-AIR PARTS MANUAL FOR DD/BB/BM/GF/MS ALL PURPOSE COLD DIRECT DRAW BACK BAR BAR MOBILE GLASS FROSTER MIXED STORAGE 115V/60HZ 220V/50HZ BEVERAGE-AIR PARTS MANUAL FOR DD/BB/BM/GF/MS ALL PURPOSE COLD DIRECT DRAW BACK BAR BAR MOBILE GLASS FROSTER MIXED STORAGE 115V/60HZ 220V/50HZ DD/BB/MS SECTION TABLE OF CONTENTS BM23 SECTION PART PAGE NUMBER

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 T-SERIES Air Conditioners T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL Rev. H 2013 Pentair Equipment Protection P/N 10-1008-177 88043249 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER...3 HANDLING AND

More information

REFIRGERADOR FRIGIDAIRE MOD. FRT22IRSHBHB0 GABIENETE NACIONAL E IMPORTACIÓN

REFIRGERADOR FRIGIDAIRE MOD. FRT22IRSHBHB0 GABIENETE NACIONAL E IMPORTACIÓN GABIENETE 1 GABIENETE 1 215937600 Shroud, evaporator fan mounting 5 5303292398 Fan blade (functional part) 8 G187559 Bushing-motor mtg,(2) 9 5303292396 Bracket, motor mounting, front 10 5304405085 Cover-evap

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

Engineering Recommendation on: Accumulators Revised 6-17-99 Issued January 10, 1979 Page 1 of 7

Engineering Recommendation on: Accumulators Revised 6-17-99 Issued January 10, 1979 Page 1 of 7 Issued January 10, 1979 Page 1 of 7 Accumulators have long been recognized by the industry as an effective means of maintaining good system balance by storing excess refrigerant as the condenser or evaporator

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

Liebert DCR Part of the SmartRow Offering. Installation Manual 3-6, Single/Redundant and 5-10 Racks Higher Capacity Cooling Units, 60Hz

Liebert DCR Part of the SmartRow Offering. Installation Manual 3-6, Single/Redundant and 5-10 Racks Higher Capacity Cooling Units, 60Hz Liebert DCR Part of the SmartRow Offering Installation Manual 3-6, Single/Redundant and 5-10 Racks Higher Capacity Cooling Units, 60Hz TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................................1

More information

Air Conditioner 457915 B57915 459516 B59516 540315 540316 640312 640315

Air Conditioner 457915 B57915 459516 B59516 540315 540316 640312 640315 RECORD THIS INFORMATION FOR FUTURE REFERENCE: Number Serial Number ADB Number ADB Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 CANADA Dometic

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information