1 2 lights module / OFF Ref: MOD-0415-N The MOD-0415-N is a lighting control module that allows to switch on/off and monitoring of 2 light sources of up to 500W respectively. This lighting circuits can be controlled locally via local push buttons and remotely via the vivimat III home automation system. The lighting circuits can be controlled by the local control buttons, and remotely by the vivimat III home automation systems. Technical characteristics Number of circuits controlled 2 Control types /OFF (switched on/off) Output type per circuit 1 relay contact NO connected to phase (5A/250VAC) Power supply 14VDC (supplied by the vivimat BUS) Consumption <30mA Maximum charge per circuit 500W Incandescent and halogen lamps 220V 500W Fluorescent and inductive load Overcurrent and overvoltage protection Temperature range -10ºC / 40ºC Compatible with vivimat III LED status indication ID configuration in the BUS Via switch Panel installation DIN rail installation Required adaptation kit ADP-0010 (NOT INCLUDED)

2 2 lights module / OFF Dimensions 42 mm 70 mm 70 mm 70 mm 25 mm 25 mm 44 mm 35 mm * MOD-0415-N + adaptation kit for rail installation DIN ADP-0010 (NOT INCLUDED) Connections Switches vivimat BUS GND vivimat BUS data vivimat BUS +V vivimat BUS Push buttons inputs 1 y 2 To controlled circuits 1 y 2 Phase Neuter -Wiring: vivimat Bus wire hose of 4x0,22mm 2. N, L,, : cable of 1,5mm 2

3 2 lights module / OFF Configuration Via the switches the MOD-0415-N can define its module address in the vivimat BUS. vivimat III can have up to 50 light modules (MOD-0400-N + MOD-0415-N). Select the address of each module as indicated in the configuration made with vivimat Project. The addresses of the modules are consecutively assigned by vivimat Project (There must not be 2 modules of the same type with the same address). ADDRESS 1 ADDRESS 2 ADDRESS 3 ADDRESS 4 ADDRESS 5 ADDRESS 6 ADDRESS 7 ADDRESS 8 ADDRESS 9 ADDRESS 10 ADDRESS 11 ADDRESS 12 ADDRESS 13 ADDRESS 14 ADDRESS 15 ADDRESS 16 ADDRESS 17 ADDRESS 18 ADDRESS 19 ADDRESS 20 ADDRESS 21 ADDRESS 22 ADDRESS 23 ADDRESS 24 ADDRESS 25 ADDRESS 26 ADDRESS 27 ADDRESS 28 ADDRESS 29 ADDRESS 30 ADDRESS 31 ADDRESS 32 ADDRESS 33 ADDRESS 34 ADDRESS 35 ADDRESS 36 ADDRESS 37 ADDRESS 38 ADDRESS 39 ADDRESS 40 ADDRESS 41 ADDRESS 42 ADDRESS 43 ADDRESS 44 ADDRESS 45 ADDRESS 46 ADDRESS 47 ADDRESS 48 ADDRESS 49 ADDRESS 50 The modules MOD-0415-N belonging to a vivimat III system must be registered in the configuration of the installation which is implemented by vivimat Project, asingning an ID number to the module and specifying which light source/s, the module is going to control.

4 2 lights module / OFF Functioning LOCAL CTROL : Local control is carried out by on or more buttons connected in parallel (see connections). A short keypress (less than 0,5 sec.) will switch on/off the lights (light circuit). Depending on the status: - If the light is switched on, it will switch off the light - If the light is switched off, it will switch on the light REMOTE CTROL: The control is carried out by the vivimat home automation system BUS. It is possible to activate the following functions remotely: - Switch on the lights. - Switch off the lights. - Know the status of the lights (switched on/off) - Configure the module. The module prioritizes local orders to remote orders. LED STATUS INDICATI: 1- Green blinking: Module operative. 2- Red blinking: Module in comunication. 3- Red or NOT iluminated: Problems with the module.

5 2 lights module / OFF Installation recommendations - Installation corresponding to a > 100 x 100mm box: The 100 x 100mm box is embedded in the wall of the housing. With 2 screws (NOT INCLUDED) we fix the MOD-0415-N to the box (1). 1 - DIN rail installation: For the DIN rail installation, you require the adaptation kit ADP-0010 (NOT INCLUDED), consisting of 2 pieces, which has to be inserted into the rear of the module (1). Once the pieces are inserted, we fit the module into the DIN rail (2). 1 2 Adaptation part x 2 3 FT-MOD-0415-N_11/01/10-ENG Product manufactured by: Dinitel 2000 S.A. - Avda. Otaola Eibar ( Guipúzcoa ) Spain T / F

Universal control module for motorized devices

Universal control module for motorized devices Ref: MOD-0105-N The MOD-0105-N is a universal module for motorized devices, blinds, awnings, curtains, doors, etc.. Allows, with vivimat BUS, the local or remote control of a motorized devices, ensuring

More information

1 light dimming module

1 light dimming module 1 light dimming module Ref: MOD0400 STAT The MOD0400 is a lighting control module that allows to dimming and monitoring of 1 halogen or incandescent light sources of up to 250W. This lighting circuit can

More information

Controller board and power supply for vivimat III systems

Controller board and power supply for vivimat III systems Controller board and power supply for vivimat III systems Ref: VIVIMAT-3.0 The controller board and power supply vivimat 3.0, is the central core of the vivimat III home automation system. The vivimat

More information

Video doorphone integration with vivimat III Ref: NA-17_v.III

Video doorphone integration with vivimat III Ref: NA-17_v.III Ref: NA-17_v.III Implicated elements In the following application note the following elements are discussed: Ref. vivimat 3.0 - vivimat 3.0 controller board and power supply Ref. vivimat project - Software

More information

Lighting Control Solutions

Lighting Control Solutions Lighting Control Solutions VS Light Controller L The VS Light Controller works with the international standard for lighting that makes it possible to connect -compatible operating devices made by different

More information

INSULATION MONITORING DEVICES

INSULATION MONITORING DEVICES 1 / 8 INDEX: Technical specifications VA40...2 Technical specifications TI1...3 Technical specifications CR5...4 Installation, configuration and use...5 2 / 8 1- INSULATION MONITORING RELAY VA40 1.1- Functions:

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Omega.com TM. RELAY-URM SERIES Universal Relay Module

Omega.com TM.    RELAY-URM SERIES Universal Relay Module Omega.com TM http://www.omega.com e-mail: info@omega.com RELAY-URM SERIES Universal Relay Module SPECIFICATIONS... 2 DESCRIPTION... 3 POWER CONNECTION... 3 INPUT CONNECTIONS Relays 1-4... 4 Figure 2:

More information

Technical Description

Technical Description abcxyz Contents 1. General...1 2. Block Diagram...2 3. First Steps...2 4. Technical Data...3 4.1 AS-Interface...3 4.2 Pin Out...4 4.3 Supply of Periphery...4 4.4 Inputs...5 4.5 Outputs...5 4.6 Mechanical

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

ADI Modules - Integrated Domestic Automation Weather and control units

ADI Modules - Integrated Domestic Automation Weather and control units ADI Modules - Integrated Domestic Automation Weather and control units ADI MODULES Radio controlled equipment for automating doors and windows, rolling shutters, lights, fans, solenoids and small domestic

More information

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011 , 2CDG 110 170 R0011 2CDC 071 020 S0012 The Room Master is a modular installation device (MDRC) in Pro M design. It is intended for installation in the distribution board on 35 mm mounting rails. The assignment

More information

I STAR COMPUTER CO., LTD

I STAR COMPUTER CO., LTD I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON

More information

Basics of Dimming. ISC Learning Centre

Basics of Dimming. ISC Learning Centre ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

General catalogue Export SMOUTS ARCHITECTEN

General catalogue Export SMOUTS ARCHITECTEN General catalogue 211 212 Export SMOUTS ARCHITECTE 13 IGHTIG COTRO ighting control More atmosphere The time when lighting control was simply switching the lights on and off is long gone. owadays, lighting

More information

Communication interface UT-4DR

Communication interface UT-4DR Roger Access Control System Communication interface UT-4DR Firmware version : 1.0.0.58 Document version: Rev. A Contents 1. Description and specification... 3 1.1 Characteristics... 3 1.2. Using the interface

More information

Important: Read Before Commissioning

Important: Read Before Commissioning Safty Instructions Important: Read Before Commissioning The user must ensure that all operators are familiar with this operating manual and follow it at all times. The operating manual must be read carefully

More information

Installation Guide - Alarm Module T941AM8

Installation Guide - Alarm Module T941AM8 Alarm Module T9AM Installation Guide - Alarm Module T9AM T9AM has physical inputs for connection to external alarm devices. Inputs are galvanically isolated, have transient protection, and can be programmed

More information

DALIK PROGRAMMING MANUAL. Gateway KNX-DALI. v1.4.3 TECHNICAL SUPPORT. Tel (+34)

DALIK PROGRAMMING MANUAL. Gateway KNX-DALI. v1.4.3 TECHNICAL SUPPORT. Tel (+34) Gateway KNX-DALI DALIK v1.4.3 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

24 Vdc Power Supplies AL-1535, AL-1536

24 Vdc Power Supplies AL-1535, AL-1536 Product Description Altus Energy Series is a reliable solution for one of the most critical issues in industrial applications: supplying power for all devices in an automation system. With a robust, compact

More information

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch 2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

MANUAL Connection Unit

MANUAL Connection Unit MANUAL Connection Unit Conditions: Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides you with the following information: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

PROFIBUS DP ACTIVE TERMINATOR

PROFIBUS DP ACTIVE TERMINATOR USER S MANUAL PROFIBUS DP ACTIVE TERMINATOR AT303 A T 3 0 3 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0 Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out

Specifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz

Reference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Comprehensive Modular Genset Controller

Comprehensive Modular Genset Controller Inteligen Click Here To Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or

More information

CENTRAL BATTERY UNIT FOR EMERGENCY LIGHTING. Installation and maintenance instructions TKT65XXB

CENTRAL BATTERY UNIT FOR EMERGENCY LIGHTING. Installation and maintenance instructions TKT65XXB 1 VOT6506E CENTRAL BATTERY UNIT FOR EMERGENCY LIGHTING Installation and maintenance instructions TKT65XXB KEEP IN A SAFE PLACE FOR LATER USE 2 TKT65XXB product description REV.4; 20.07.2009 JAK Table of

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

SA/S Switch Actuators

SA/S Switch Actuators ABB i-bus EIB / KNX SA/S Switch Actuators ABB STOTZ-KONTAKT GmbH - Folie 1 Range of Products SA/S x.x.x New development of a complete range of Switch Actuators (Binary outputs) Fulfils current demands

More information

General catalogue Export SMOUTS ARCHITECTEN

General catalogue Export SMOUTS ARCHITECTEN General catalogue 2011-2012 Export SMOUTS ARCHITECTEN 11 LED LIGHTING PUUR INTERIEURARCHITECTEN LED lighting Atmosphere and comfort in all simplicity We cannot imagine a modern home without atmospheric

More information

Static Transfer Switch (STS) For LCE-H Series Inverters

Static Transfer Switch (STS) For LCE-H Series Inverters Page 1 of 16 Static Transfer Switch (STS) For LCE-H Series Inverters Theory of Operation and User s Manual (May 2005, Revision A) Page 2 of 16 Table of Contents 1 Introduction...3 2 Description and Operation...4

More information

Why Do I need a Diode Kit When I convert to LED s?

Why Do I need a Diode Kit When I convert to LED s? Note: The tips and explanations in this document highlight the use of a diode installed in the dash panel with a single indicator light on most metric motorcycles. Should you decide to undertake this project

More information

TRS 06 TRANSPONDER READER- AND CONTROL UNIT. (Door Access Control System) Mounting Manual and Operating Manual

TRS 06 TRANSPONDER READER- AND CONTROL UNIT. (Door Access Control System) Mounting Manual and Operating Manual TRS 06 TRANSPONDER READER- AND CONTROL UNIT (Door Access Control System) Mounting Manual and Operating Manual Table of Contents 1. Function and Description of the Device 2 2. Installation Instructions

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

VB IP. IP Communicator. Installer Manual

VB IP. IP Communicator. Installer Manual VB IP IP Communicator Installer Manual 13 May 2015 CONTENT 1. INTRODUCTION...3 2. SYSTEM STRUCTURE...3 3. SYSTEM PROGRAMMING WITH PC SOFTWARE...5 4. TROUBLESHOOTING...7 5. ENIGMA II TRANSMISSION TEST...9

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

2 -Wire Intercom System

2 -Wire Intercom System 2 -Wire Intercom System USER MANUAL Model: CDV-91 1.Parts and Functions Camera Lens Night View LED Speaker 176 mm Nameplate Call Button Microphone Rainy Cover 90 mm 23 mm 2.Terminal Descriptions 3 Lock

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Save time and wiring cost with peer-to-peer

More information

Douglas Lighting Controls - Specifications W-2000 Networked Systems

Douglas Lighting Controls - Specifications W-2000 Networked Systems 1. PAR T 1 - General 1.1 Overview - Specifications W-2000 Networked Systems 1.1.1 Provide a complete low voltage lighting control system for the building as shown on the plans and specified herein. 1.1.2

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Zelio RXG interface relay

Zelio RXG interface relay Zelio RXG interface relay Essentials All-in-1 Document 2014 1 Presentation Zelio RXG presentation Zelio RXG interface relay is widely used in PLC interface application, for its reliable installation, easy

More information

Srivatsan Embedded Systems & Technologies -Providing Smart Solutions

Srivatsan Embedded Systems & Technologies -Providing Smart Solutions SMS ALERT SYSTEM User Manual Description: SMS alert system is the remote control alert device. It will continuously monitor the certain input parameter to check if the values are well within the user defined

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

by Bkav MODEL: SH - CT4R

by Bkav MODEL: SH - CT4R by Bkav MODEL: SH - CT4R www.smarthome.bkav.com Mfr Code: 893604393UGCT4R Copyright 2015 Bkav SmartHome Co., Ltd. All rights reserved. UGCT4R/V2.0/0615 USER GUIDE 4-CHANNEL CONTROLLER SH - CT4R Bkav SmartHome

More information

USER GUIDE ARDBOX RELAY

USER GUIDE ARDBOX RELAY USER GUIDE ARDBOX RELAY Version: 004-001-70_Ardbox_Relay Page2 Ardbox User Guide: 1 Contents 2 ARDBOX... 3 3 Precautions... 4 1.1. Arduino Board... 4 1.2. Intended Audience... 4 1.3. General Precautions...

More information

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

Lighting Control Overview

Lighting Control Overview Overview Lighting Control Overview RTC Inbuilt real time clock Automatic daylight savings adjustment Atomic clock synchronisation (NTS). Triggers Inputs Schedules Network Conigurable inputs with dynamic

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com

DALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com Gateway KNX-DALI DALIX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

Temperature Controller (Heat Pumps)

Temperature Controller (Heat Pumps) 3 346 Temperature Controller (Heat Pumps) RWD34 RWD44 For comfort control in HVAC & R systems Standalone electronic controller Programmable controller with preconfigured applications Two universal inputs

More information

Door Access Control with the VoIP interface Release 1.4

Door Access Control with the VoIP interface Release 1.4 Door Access Control with the VoIP interface Release 1.4 NISTA DEVICES GmbH 2013 All Rights Reserved 1 IP Door Phones IP39-4X Quick Installation Guide Document Release: 1.04 Release Date: 14-Jun-15 2 NOTICE

More information

The TWIN system is a system based on a 2 wire non polarized bus. The power, data and audio signal pass through these 2 wires simultaneously..

The TWIN system is a system based on a 2 wire non polarized bus. The power, data and audio signal pass through these 2 wires simultaneously.. Description TWIN intercom system The TWIN system is a system based on a 2 wire non polarized bus. The power, data and audio signal pass through these 2 wires simultaneously.. To make a duplex audio connection

More information

SystempaK (Digital/Single Case) Single-Input Arithmetic Relay Module Model J-SCP 90/95

SystempaK (Digital/Single Case) Single-Input Arithmetic Relay Module Model J-SCP 90/95 No.SS2-2330-0850 (Rev. 1) SystempaK (Digital/Single Case) Single-Input Arithmetic Relay Module Model J-SCP 90/95 Introduction The Single-Input Arithmetic Relay Module (J-SCP90/95) is a signal conversion

More information

MULTIPLEXED AMPLIFIER SERIES

MULTIPLEXED AMPLIFIER SERIES MULTIPLEXED AMPLIFIER ERIE In an industry where most products resemble each other, we have strived to make sure that Telco only resembles Telco in terms of quality, reliability, performance and ease-of-use.

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Quick Start Guide. Industrial Managed Gigabit Ethernet PoE+ Switch LPH2004A-2GSFP

Quick Start Guide. Industrial Managed Gigabit Ethernet PoE+ Switch LPH2004A-2GSFP LPH2004A-2GSFP Industrial Managed Gigabit Ethernet PoE+ Switch Quick Start Guide Has (4) PoE+ 10/100/1000-Mbps twisted-pair and (2) SFP Gigabit ports. Customer Support Information Order toll-free in the

More information

LAMBDA PROBE MODULE ML-2

LAMBDA PROBE MODULE ML-2 LAMBDA PROBE MODULE ML-2 page 2 Spis treści Spis treści 1 General information 4 1.1 Introduction 4 1.2 Contents 4 1.3 Safety precautions 5 1.4 Disposal of old equipment 6 2 Connecting to the system 7 2.1

More information

INSTALLATION AND USER GUIDE GSM CONTROLLER

INSTALLATION AND USER GUIDE GSM CONTROLLER GSM Controller INSTALLATION AND USER GUIDE GB GSM CONTROLLER ---------------------------------------------------------------------------------- 3-10 2 INSTALLATION AND OPERATION MANUAL GSM Controller IMPORTANT!

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,

More information

APOLLO Plus PORTABLE DIMMER SERIES

APOLLO Plus PORTABLE DIMMER SERIES APOLLO Plus PORTABLE DIMMER SERIES USER S MANUAL Any reproduction by means or whole of this user manual in any way, is prohibited without the consent of ELECTRON S.A. ELECTRON S.A. reserves the right to

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com

More information

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES D5000 / D00 SERIES SAFETY RELAYS SERIES High Integrity Safety Relays Suitable for applications according to IEC 608 and IEC 611 Relays technology for safety DTS0262-1 27 SAFETY RELAY - FEATURES SAFETY

More information

CAN-BUS INTERFACE INSTALLATION MANUAL OPERATION WITH USB BOOTLOADER

CAN-BUS INTERFACE INSTALLATION MANUAL OPERATION WITH USB BOOTLOADER CAN-BUS INTERFACE INSTALLATION MANUAL OPERATION WITH USB BOOTLOADER INTERFACE INSTALLATION MANUAL GENERAL INFORMATION The module is designed for translating digital signals transmitted over CAN-Bus. The

More information

UPiS - Uninterruptible Power intelligent Supply

UPiS - Uninterruptible Power intelligent Supply UPiS - Uninterruptible Power intelligent Supply www.pimodules.com Introduction The UPiS is an Advanced Powering add-on Module for the RaspberryPi that adds a wealth of additional features to the powering

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Time relay module DC 24 110 V, programmable with positive action contacts

Time relay module DC 24 110 V, programmable with positive action contacts Subject to technical modification 815008.00 Identification Type ZR6-5008.00 Product version Datasheet version 00 Use/Application/Properties Description The programmable time relay consists of 1 relay with

More information

Models PS and PS Sensor Interface Modules

Models PS and PS Sensor Interface Modules AC Power Supply Interfaces for Use with dc-operated Sensors Features Low-cost interface between ac power supply and dc-operated sensors Power supply can source up to 100 milliamps Integral TEACH push button

More information

RCP-0006 Through RCP-0042 System Manual

RCP-0006 Through RCP-0042 System Manual Touch-Plate Lighting Controls RCP SERIES RCP Series System Manual RCP-0006 Through RCP-0042 System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323 Fax: 260-420-3651

More information

SB485,SB485L,SB232. USB to RS485, RS422 and RS232. industrial converters. With galvanic isolation. 18. August 2014 w w w. p a p o u c h.

SB485,SB485L,SB232. USB to RS485, RS422 and RS232. industrial converters. With galvanic isolation. 18. August 2014 w w w. p a p o u c h. USB to RS485, RS422 and RS232 industrial converters With galvanic isolation 18. August 2014 w w w. p a p o u c h. c o m SB485,SB485L,SB232 Datasheet Created: 1/19/2005 Last update: 8/18/2014 12:38 Number

More information

Industrial 8-port Gigabit Ethernet Switch User s Manual

Industrial 8-port Gigabit Ethernet Switch User s Manual Industrial 8-port Gigabit Ethernet Switch User s Manual - 0 - Content 1. Introduction...2 1-1. Features...2 1-2. Packing List...3 2. Hardware Description...4 2-1. Dimensions...4 2-2. Front Panel...4 2-3.

More information

ARDBOX FAMILY USER GUIDE

ARDBOX FAMILY USER GUIDE ARDBOX FAMILY USER GUIDE Page2 User Guide: 1 Contents 2 ARDBOX FAMILY GUIDE... 3 3 Technical Specifications... 4 3.1 General Specifications:... 4 3.2 Perfmance Specification:... 4 4 I/Os out... 5 5 Communication

More information

User s Manual RF Wireless Receiver

User s Manual RF Wireless Receiver User s Manual Model 15 MHz Remote Control Receiver TL-RX-15 User Manual Contents 1. General Descriptions... P.2 2. Receiver Package Description... P.. Specifications... P. 4. Installation & Connections...

More information

Operating instructions I / DALI EASY II Version 1.0. General. Contents. General

Operating instructions I / DALI EASY II Version 1.0. General. Contents. General Operating instructions I / 2007 General Contents General Installation Appendix Safety information 2 Definition of terms 3 Application and function 4 Components 5 Wiring diagrams 6 Wiring diagrams 7 System

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Electric resistors for Roof Top ACTIVA

Electric resistors for Roof Top ACTIVA Electric resistors for Roof Top ACTIVA 045-090 Options and Accessories, Installation manual Ref.: N-40334_EN 0909 Index Index 1 Electric resistors for Roof top ACTIVA 045-090... 1 1.1 Electric resistor

More information

Vision Color - 7 User Manual v.iii_1.2

Vision Color - 7 User Manual v.iii_1.2 Vision Color - 7 User Manual v.iii_1.2 Copyrights Ref. document: MVISIONCOLOR-v.III-11-11-ESP The information contained in this guide can be liable to changes without previous warning. This document cannot

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable