Lighting Control Overview
|
|
- Janice Burke
- 7 years ago
- Views:
Transcription
1 Overview Lighting Control Overview RTC Inbuilt real time clock Automatic daylight savings adjustment Atomic clock synchronisation (NTS). Triggers Inputs Schedules Network Conigurable inputs with dynamic modes and multistaged override timers for: Push buttons and switches Daylight sensors Occupancy sensors RF receivers, etc. Automatic time based events Sunrise and sunset with offset Repeat timers Linked timers with offset Holidays and holiday schedules. Touch screen Computer with building monitor Linked controllers Ps/smartphones SMS (text messages). Actions Direct Arc Level LI Commands Extended Commands Direct ARC power control Logarithmic dimming curve with an arc power level of 0.1% to 100%. Dimming commands: Min, Max, etc. Scenes with individual light levels Status reporting Coniguration. Conditional commands: Min_If_On, etc Controller commands Timed sequences. Control Targets Ballasts Up to 64 ballasts (1 loop) or up to 128 ballasts (2 loops). Groups Up to 16 LI Groups per loop + 48 extended Groups per loop. Broadcast Single loop or all loops. Outputs 8 onboard outputs to drive relays. CLIPCOM May
2 Schematic Simple LI Room Control Schematic 64 Addresses (max.) per LI Loop (max. 300m) LI-01 LI Power Supply 250mA max. LI Light Fittings Optional Ethernet Controller/Gateway with RTC and I/O LI LI Light Sensor LI Occupancy Sensor LI LI is an international standard lighting control system. The schematic diagram shows a LI network (LI-01) powered by a LI power supply. The eight light fittings (addressed from 00 to 07) can be any light fitting from any manufacturer fitted with LI ECG (electronic control gear). LI ECGs are available for FL and CFL lamps, discharge lamps, low voltage halogen lamps, incandescent lamps, LEDs, emergency lights, etc. The light fittings are controlled by LI ECDs (electronic control devices) such as LI wallplates and LI sensors from any manufacturer, including LI control s DC100 Series of LI control devices. LI can also control legacy light fittings including fixed output, analogue 1 to 10V and DSI dimmable fittings. CLIPCOM May
3 Schematic Floor Control Schematic 64 Addresses (max.) per LI Loop (max. 300m) LI Power Supply 250mA max. DCLxx-xx LI LI EMG 63 (06) DCBM LI Line Controller Ethernet and Sensors Occupancy and/or Light Sensor To Riser or Hub for Optional Computer Monitoring and Control To Security or Access Control Panel LI Power Supply 250mA max. 00 LI EMG (60) LI EMG (61) LI Sensor LI-02 LI The controller manages up to two LI networks. The controller includes scheduling, digital inputs, digital outputs and an RJ45 Ethernet network socket for computer monitoring and control. CLIPCOM May Inputs on the controller can be used for wallplates, sensors and interfacing to security and access control panels, etc. Each LI network requires a LI power supply and a LI interface. The controller manages a LI group based on inputs from standard switches and sensors.
4 Schematic Building Control Schematic 64 Addresses (max.) per LI Loop, 00 to 63 Riser to Higher Floors 64 Addresses (max.) per LI Loop, 00 to 63 LI-11 LI and Sensors and Sensors To Master Override Switch To Security/Access Control Panel Switchboard LI-12 LI DCLxx-xx LI Sensor LI EMG (61) LI Ethernet LI Area Controller with and Sensors The controller manages up to two LI networks and includes scheduling, digital inputs, digital outputs and an RJ45 Ethernet socket for computer monitoring and control. Riser to Lower Floors The switchboard contains controller/gateways, LI power supplies and LI interfaces. CLIPCOM May
5 Schematic Typical Switchboard Schematic Riser to Control Room Switchboard DCLPSxxx LI Networks LI-01 DCLPSxxx LI-02 Ethernet Switch DCLPSxxx LI-03 DCLPSxxx LI-04 DCLPSxxx DCLPSxxx LI-05 LI-06 The controller manages up to two LI networks. Each controller includes scheduling, inputs, outputs and an RJ45 Ethernet socket for computer monitoring and control. Each LI network requires a power supply and an interface. Power supplies for the controller and Ethernet switch are not shown in the schematic diagram. Refer to wiring diagrams for full details. CLIPCOM May
6 Wiring BM-LI Controller Wiring Overview To CCT Breaker Starter Socket Socket or T-Piece L N LI-A LI ECG (Addr 0) LI ECG (Addr 1) LI ECG (Addr 3) LI ECG (Addr 63) DCPxx/xx DCLP250 or DCLP200 DCLP250 or DCLP200 SWITCHBOARD LI EMG (Addr 2) LI EMG (Addr 4) DCL DCL0-02 LI Controllers Including: LI s, Occupancy Sensors, Light Sensors, Group Controllers, Scene Controllers Touch Screens, etc. -V +V DC IN - + DC IN DCLCD35 Control Panel or DCLCD70 Touch Panel CAT5e or CAT6 BMxxxx-LI LINE CONTROLLER INPUTS Ethernet Switch To LI-B To Switches and Push Buttons, Occupancy and Light Sensors, Security and Access Control Panels, etc. Ethernet Network to Computers, Touch Screens, LCD Control Panels and BM-LI Network Controllers BUILDING MONITOR The diagram depicts a typical wiring layout for a LI line. The DCPxx/xx power supply provides d.c. power for BM-LI line controllers and for sensors connected to BM-LI inputs. The DCLP200 or DCLP250 are current limited, DIN rail mount LI power supplies. One DCLP200 or DCLP250 is required per LI line. The is the LI communications interface for the BM-LI line controller. One is required per LI line. Each LI line can support up to 64 LI ECG s addressed from 0 to 63. LI ECGs are available for FL and CFL lamps, LV halogen, HID, LEDs, emergency fittings, fixed output, DSI and 1 to 10V analogue fittings, etc. The computer and other Ethernet equipment is optional and can be used to monitor and control the system. LI lines must be wired to the LI standard and to local regulations. CLIPCOM May
7 Wiring BM-LI Controller Digital Outputs V DC Power Supply DCBM LI Line Controller Plug Relay and Base (typical H72 x W28 x D67mm each base) Internal Circuit Output Circuit +K Load OUT/AUX External Components + - External Power Suppy The DCBM LI line controller has eight internal digital outputs; OUT 0 to OUT 7. Each output can sink 200mA. When using the digital outputs to switch inductive loads it may be necessary to power K with a separate power supply. Relay base terminals (arrangement shown is for PTF08A): 1. Contact 1 Normally Closed 2. Contact 1 Normally Open 3. Contact 1 Common 4. Contact 2 Normally Closed 5. Contact 2 Normally Open 6. Contact 2 Common 7. Coil 8. Coil CLIPCOM May
8 Wiring DCBM-LI Line Controller Ethernet Overview Ethernet Switch Administration Computer (optional) BUILDING MONITOR Ethernet Switch Level xyz Distribution Board DCBM-LI Line Controller LI-01 LI-02 CAT5e Cable DCBM-LI Line Controller LI-03 LI-04 DCBM-LI Line Controller Ethernet Cabling to Other Levels DCLCD35 Control Panel or DCLCD70 Touch Panel LI-05 LI-06 Ethernet network cabling must be completed to Ethernet standards. The Ethernet switch in the distribution board is not required if a separate Cat5. cable is run from the main switch to each DCBM LI line controller. CLIPCOM May
9 Wiring Typical Switchboard Layout a.c. Supply LI-A LI-B N L +V -V B A DCPxx/xx Power Supply RJ45 Ethernet To Switches and Push Buttons, Occupancy and Light Sensors, Security and Access Control Panels, etc. BMxxxx-LI Line Controller Ethernet Gateway DCLPxxxxx Dimensions (shown in mm) Part Number Height Width Depth DCP12/ DCP12/ DCP24/ DCP24/ Part Number Height Width Depth DCBM DCBM DCBM DCBM DCLPxxxxx should be separated by spacers to allow air flow and avoid overheating. DCPxx/xx power supplies can power multiple BM-LI line controllers and sensors, according to the accumulated load. DCLP DCLP CLIPCOM May
10 Wiring LI DCLxxxxx Wiring Overview To CCT Breaker Starter Socket Socket or T-Piece L N L N L N DCLxxxxx (1 Address) 12VDC IN0 IN1 IN2 IN3 OUT0 OUT1 LI Control DCL Series DCLIO-0402 Room Controller DCLO-02 2-Channel Output Module Input Circuit using 12V Relay Input Circuit Output Circuit 12V d.c. 12V d.c. 12V d.c. C R2 R1 INx Relay (12V Coil) C R2 R1 Internal Circuit External Components Internal Circuit External Components Internal Circuit External Components INx OUTx Load (12V Relay Coil) CLIPCOM May
KNX Lighting Control System
KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting
More informationBasics of Dimming. ISC Learning Centre
ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer
More informationGLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS- - - - - - SpaceBuild Specification Worksheet. Touch Screens
SpaceBuild Specification Worksheet GLPHASE System The GLPHASE SpaceBuilder system is ideal for medium-sized spaces that require additional options such as expansion modules for more load types, touch screens,
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationSpecifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out
SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0
More informationLighting Management solutions
Lighting Management solutions Best practice guide for office buildings PUTTING A STOP TO ENERGY WASTE INTRODUCTION Table of contents 1 Lighting control Best Practice Guide for Office Buildings 2 Guide
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationDigidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide
Digidim 458/DIM8 8-Channel Dimmer Module Installation and User Guide Introduction The 458/DIM8 is an 8-channel digital thyristor dimmer module, for leading-edge dimming of resistive and inductive loads.
More informationDALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions
DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable
More informationFL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
More informationB.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
More informationInductive Proximity Sensors
M12 Inductive Proximity Sensors Standard Length Mini's Extended Sensing 3 Wire DC 2 Wire DC 2 Wire AC (Wiring Schematic) 3 Wire DC PNP Normally Open (1) IMM32122C IMM35124C IMN32122C IMN35124C IMN32122M12
More informationControlers. Controler
s 4 INDEX Controlers Color Wheel LED Remote page 4 Push Button RGB Controler page 5 Dimmable LED Power Supplies page 6 DMX Controler Sunlite STICK 2 page 7 DMX Controler Sunlite STICK-GA2 page 8 DMX Controler
More informationABB i-bus KNX DALI-Gateway DG/S 8.1
Product manual ABB i-bus KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes Dynamic
More informationGLPAC-DIMFLV Crestron Green Light Integrated Lighting System
> > Up to 8 channels of 0-10 Volt dimming control > > Works in 100 to 277 VAC systems > > 16-Amp load rating per channel > > Built-in Control System with Cresnet and Ethernet port > > UL924 compliant emergency
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More information13 SERIES. Electronic step relays 10-16 A 13.81 13.91
13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function
More informationbasicdim DGC Compact control module
luxctrol lighting control sstem DGC Compact control module Product description Compact dimensions for luminaire installation For up to 0 DSI or LI ballasts ( per output channel) LI IN input LI/DSI output
More informationPHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps
EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim
More information15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationPHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps
Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer
More informationoverview DyNet over RS485
technical guide systems integration overview Integration between various control systems within projects, reduce end-users need to have multiple interactions to perform what seems like one task such as
More informationOperating instructions IV / 2007
General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
More informationcontents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationSwitch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
More informationABB i-bus EIB / KNX Room Controller
Product Information ABB i-bus EIB / KNX Room Controller Intelligent Installation Systems The Concept One Room Controller per Room The Room Controller consists of a basis device, into which up to 8 selected
More informationInstallation and User Guide
Installation and User Guide 458-UNI8 8-Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8-channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationABB i-bus EIB / KNX DALI-Gateway DG/S 8.1
Product manual ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1 Intelligent Installation Systems This manual describes the function of the DALI-Gateway DG/S 8.1 with the application program Dim Slave Lightscenes
More informationTransmitter Actuator 230V wave UP 560. Operation
Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
More informationC-Bus Basic Training Manual Volume 1. 1A. Introduction to C-Bus 1B. C-Bus Concepts 1C. C-Bus Hardware Revision Number: V2
C-Bus Basic Training Manual Volume 1 1A. Introduction to C-Bus 1B. C-Bus Concepts 1C. C-Bus Hardware Revision Number: V2 Copyright Clipsal Australia Pty Ltd 2007. All rights reserved. This material is
More informationFL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5
F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via
More informationWhale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
More informationEBDSPIR-DD, EBDSPIR-DD-IP
Product Guide EBDSPIR-DD, EBDSPIR-DD-IP Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationDMX512 Switch (stand alone mode) DALI Touch Dimmer Switch
0 DMX Switch (stand alone mode) DAI Touch Dimmer Switch 78.9 70. 8.. Comply to standard protocol DMX(990) and in compliance with DMX products from other international incorporations. DMX address is manual
More informationEXTERNAL DIMENSIONS AND PARTS
FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special
More informationSolid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
More informationELABOTrainingsSysteme. Aus- und Weiterbildung GmbH. Home and Building Control KNX / EIB. www.elabo-ts.com
Aus- und Weiterbildung GmbH Home and Building Control KNX / EIB www.elabo-ts.com Design and commissioning of KNX/EIB systems www.elabo-ts.com Hardware page 2-5 Software page 6-9 Projects page 10-15 LOGO!
More informationClass 2 transformer (TBT) Low Tension Conform to EN 60742. A LED turns ON when the current exceeds 1 A at the 14V output connector
Technical notice TECHNICAL CHARACTERISTICS Power Class 2 transformer (TBT) Low Tension Conform to EN 60742 Rechargeable battery 16 Vac, 50-60Hz 50 Va min. 250 Va max 12 V, 7AH Protection A LED turns ON
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationOperating instructions II / 2004
Operating instructions II / 2004 Light and presence sensor TOUCH DIM LS/PD LI OSRAM GmbH Costumer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg, Germany www.osram.com www.osram.de Tel. : (+49)
More information12 Series - Time switches 16 A. Features 12.01 12.11 12.31
Mechanical time switches - daily time setting Type 12.01-1 Pole 16 A CO (SPDT) Type 12.11-1 Pole 16 A O (SPST-O) 17.6 mm width Type 12.31-0000 - 1 Pole 16 A CO (SPDT) Type 12.31-0007 - 1 Pole 16 A CO (SPDT)
More informationFuture proof lighting management
Future proof lighting management LightMaster Modular Lighting Management for today s fast changing world LightMaster Modular is a new building block concept in lighting management systems designed to
More informationTMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationIO-RM3 3-Stage Relay Module
Page 1 of 6 IO-RM3 3-Stage Relay Module Features: Benefits: Link selectable modes binary, heat/cool, staged or sequenced On/Off/Auto links for ease of commissioning DIN Rail mounting Fault finding LED
More informationEthernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
More informationABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationReference Design. conference rooms
Reference Design conference rooms Tomaro Design Group conference rooms The modern commercial conference room embraces communication and multi-media technology from projectors and video conferencing, to
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationOptimize your simple machines... Modicon M218 Selection Guide
Optimize your simple machines... Modicon M218 Selection Guide Compact Solution for Simple Machines Optimized Logic Controller Modicon M218 With intelligent software platform, specialized functional s,
More informationLiteKeeper 4 & 8 Programming Guide and User Manual
LiteKeeper 4 & 8 Programming Guide and User Manual Table of Contents Safety Instructions... 3 Chapter 1: Introduction... 4 p1 How It Works... 4 What are relays?... 4 What are inputs?... 4 How do I program
More informationSECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationmecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
More informationApplied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
More informationInverter / Charger Installation General Operations and AC and DC Connections
Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better
More informationPLC training panel (Twido version)
PLC training panel (Twido version) User manual Name School of Trades Produced by: GJR October 2012 Colour leaves: 9 BW leaves: 2 Cover colour: White Cover image: G.J.Rogerson Acknowledgments: Much of the
More informationABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
More informationSmart relays Zelio Logic Step into an intuitive world!
Smart relays Zelio Logic Step into an intuitive world! Simply Smart! Leveraging ingenuity and intelligence for ease of use Simply select your Zelio Logic! Designed for the management of simple automation
More informationBLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR
BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR This Block Occupancy Detector recognises the current drawn by moving trains within a block, and can operate a number of built-in programs
More informationPush button 3gang standard flush-mounted 751633xx
Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationEcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module
EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron EcoSystem dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron EcoSystem bus
More informationPush button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
More informationGeneral Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700
General Purpose, Interposing, Solid-State and Specialty Relays Bulletin 700 Breadth of Product. Ease of Selection. World-class Allen-Bradley relays and timing relays by Rockwell Automation are designed,
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationApplication Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationCombi B Alarm box. Mounting instructions
Combi B Alarm box Mounting instructions EN Mounting instructions Alarm box Combi B VdS, G113064, G113065, G113066 Table of Contents 1 Description... 3 2 System overview... 3 3 Structure... 3 3.1 Power
More informationDALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
More informationHighly flexible the right KNX/DALI gateway for every requirement
The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with
More informationDigital I/O: OUTPUT: Basic, Count, Count+, Smart+
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.
More informationSnap-It. This is an accessory (switch machine) decoder
Snap-It $19.95 For use with most twin coil switch machines such as: Atlas, LifeLike, Peco, Bachmann, NJ, Rix, Kemtron and others Dimensions: 1.80" x 1.50" (46 x 38 mm) This is an accessory (switch machine)
More information4000 Series audio door entry system (using 9307.1 power supply) Installation Instructions IN9307.1
Unit, AM Business Park umberland Avenue Park Royal, London, NW 7QL t : f : w : www.doorentrydirect.com 4 Series audio door entry system (using 7. power supply) Installation Instructions IN7. 7 Getting
More informationWxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
More informationChapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
More informationPassion for KNX innovation
Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can
More informationSYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationTrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
More informationAUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
More informationCM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
More informationInstallation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
More informationAPOLLO Plus PORTABLE DIMMER SERIES
APOLLO Plus PORTABLE DIMMER SERIES USER S MANUAL Any reproduction by means or whole of this user manual in any way, is prohibited without the consent of ELECTRON S.A. ELECTRON S.A. reserves the right to
More information12V Dimmable Driver EL-TMDRVR
Elemental LED, LLC website: elementalled.com 11 9 5 P a r k A v e., S u i t e 2 11 Emeryville, CA 94608 toll free 877.564.5051 fax 510.740.4457 12V Dimmable Driver EL-TMDRVR ETL Listed #4001928 CSA Listed
More informationFL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5
EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim
More information