LOADING DOCK SPECIFICATIONS

Size: px
Start display at page:

Download "LOADING DOCK SPECIFICATIONS"

Transcription

1 LOADING DOCK SPECIFICATIONS

2 LOCATION MAP LOADING FLOOR PLAN

3 DIMENSIONS Storage W x D (m) 9.6m x m x 0.5m 4.8m x 0.5m - N/A Ceiling Height 4m 4m 4m - N/A CAPACITIES Type of Vehicle Floor Load Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) (weight in kg) N/A - N/A A move-in/move-out schedule is required to identify the loading dock schedule. FACILITIES AND FEATURES No. of bays Floor Service Pit Yes Storage Space No Paging system No Flooring Fine polished concrete Steel post No Security Access Yes Ramp No Toilets Male & Female Levelers No Disability Access Yes Seals Yes HSE Fire extinguisher & fire hose reel Temperature Controlled available Shutter switch Easy push button Bumpers Yes Lighting Description Floodlights Other ancillary room/s Valve Control, electrical room,,waste recycle room Drive-on floor access points Yes Service Lift Service Power Supply 6 x pin square outlet x amp Freight Elevator Location Inside (Right) Capacity 5500 DOORWAY AND ENTRANCES Width.4m Height.5m Depth 6.5m No. of Entrance/s (Excluding Venue (s) serviced and accessible via this loading dock Dock Door) No. of Exit/s (Excluding Dock Door) Exhibtion Hall, Conference Hall Door: Width (m) 8.9m Height (m) 4m Location Front a) Dock Door (from service road) 9m x 4mH b) Dock Door (to building) 6m x 4mH c) Side Door 0.9m x.mh d) Outer roller shutter 6m x 4mH e) Inner roller shutter 4.7m x 4mH Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

4 LOCATION MAP LOADING FLOOR PLAN

5 DIMENSIONS Storage W x D (m) 9.6m x 0.5m 4.8m x 0.5m 4.8m x N/A Ceiling Height 4m 4m 4m - N/A CAPACITIES Type of Vehicle Floor Load Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) (weight in kg) N/A - N/A A move-in/move-out schedule is required to identify the loading dock schedule. FACILITIES AND FEATURES No. of bays Floor Service Pit Yes Storage Space No Paging system No Flooring Fine polished concrete Steel post Yes Security Access Yes Ramp No Toilets Male & Female Levelers No Disability Access Yes Seals Yes HSE Fire extinguisher & fire hose reel Temperature Controlled available Shutter switch Easy push button Bumpers Yes Lighting Description Floodlights Other ancillary room/s Eletricity room, waste recycle room, Laudry room Drive-on floor access points Yes Service Lift Service Power Supply 6 x pin square outlet x amp outlet Freight Elevator Location Inside (Right) Capacity 5000 Floors - Width.9m Height.5m SDepth i d.5m DOORWAYS AND ENTRANCES No. of Entrance/s (Excluding Dock Door) No. of Exit/s (Excluding Dock Venue (s) serviced and accessible via this loading dock Exhibition Hall, Auditorium and Auditorium Door) Door: Type Shutter Width (m) 9m Height (m) 4m Location Front Distance to hall a) Dock Door (from service road) 9m x 4mH t b) Dock Door (to building) 6m x 4mH c) Side Door 0.9m x.mh d) Outer roller shutter 6m x 4mH e) Inner roller shutter 4.7m x 4mH Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

6 LOCATION MAP LOADING FLOOR PLAN

7 DIMENSIONS 4 5 Storage W x D (m) 8m x 0m.8m x 8m.8m x 8m.8m x 8m.8m x 8m.8m x 8m SQ M Ceiling Height 0m 0m 0m 0m 0m 0m.7m CAPACITIES Type of Vehicle Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) Skips Car Parking Main Door Way Not Allowed - Main Door Way Not Allowed - Main Door Way Not Allowed - 4 Not Allowed - 5 Not Allowed - FACILITIES AND FEATURES No. of bays 5 Floor Service Pit No Storage Space Yes () Paging system Yes Flooring Concrete Steel post Yes Security Access Yes Ramp No Toilets Female Levelers No Floor Load (weight in kg) Disability Access Yes Bumpers No HSE Fire extinguisher & hose Temperature Outdoor reel available Shutter switch Easy push button Other ancillary room/s Paint wash room, transformer room, electrical Lighting Description Floodlights room, battery charging room, waste recycle room Drive-on floor access points Yes Service Lift Service Lift Power Supply 8 x pin square outlet x amp outlet Freight Elevator Location Back Capacity - Width m Height 4m Door (w).8m Door (h).6m DOORWAYS AND ENTRANCES No. of Entrance/s(Excluding Venue Exhibition Hall Dock Door) No. of Exit/s (Excluding Dock Door) (s) serviced and Door: Type Bifold Width (m) 7.6 Height (m) 6. Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

8 4 LOCATION MAP LOADING FLOOR PLAN

9 4 DIMENSIONS Storage 4 W x D (m) 8m x 0m.8m x 8m.8m x 8m.8m x 8m.8m x 8m.8m x 8m 9 SQ M Ceiling Height 0m 0m 0m 0m 0m 0m.9m CAPACITIES Type of Vehicle Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) Skips Car Parking Not Allowed - Not Allowed - Main Door Way Not Allowed - 4 Main Door Way Not Allowed - 5 Main Door Way Not Allowed - FACILITIES AND FEATURES No. of bays 5 Floor Service Pit No Storage Space Yes Paging system Located in Flooring Concrete Steel post Yes Security Access Yes Ramp No Toilets Male Levelers No Floor Load (weight in kg) Disability Access Yes Bumpers No HSE Fire extinguisher & hose Temperature Outdoor reel available Shutter switch Easy push button Other ancillary room/s Paint wash room, transformer room, electrical room, battery charging room, waste recycle room Lighting Description Floodlights Drive-on floor access points Yes Service Lift Service & Passanger Power Supply 8 x pin square outlet x amp outlet Freight Elevator Location Back Capacity - Width m Height 4m Door (w).8m Door (h).6m DOORWAYS AND ENTRANCES No. of Entrance/s (Excluding Venue (s) serviced and Exhibition Hall 4 Dock Door) No. of Exit/s (Excluding Dock accessible via this loading dock Door) Door: Type: Bifold Width (m) 7.6 Height (m) 6. Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

10 5 LOCATION MAP LOADING FLOOR PLAN

11 5 DIMENSIONS Storage 5 W x D (m) 7.5m x 0m.8m x 8m.8m x 8m.8m x 8m.8m x 8m - 0 SQ M Ceiling Height 0m 0m 0m 0m 0m -.9m CAPACITIES Type of Vehicle Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) Skips Car Parking Not Allowed - Main Door Way Not Allowed - Main Door Way Not Allowed - 4 Not Allowed - 5 N/A N/A N/A N/A - FACILITIES AND FEATURES No. of bays 4 Floor Service Pit No Storage Space Yes Paging system Yes Flooring Concrete Steel post Yes Security Access Yes Ramp No Toilets Male Levelers No Floor Load (weight in kg) Disability Access Yes Bumpers No HSE Fire extinguisher & hose Temperature Outdoor reel available Shutter switch Easy push button Other ancillary Paint wash room, transformer room, electrical room, battery charging room, waste Lighting Description Floodlights room/s recycle room Drive-on floor access points Yes Service Lift Service & Passanger Power Supply 8 x pin square outlet x amp outlet Freight Elevator Location Back Capacity - Width m Height 4m Door (w).8m Door (h).6m DOORWAYS AND ENTRANCES No. of Entrance/s (Excluding Dock Door) No. of Exit/s (Excluding Dock Door) Venue (s) serviced and accessible via this loading dock Exhibition Hall 5 Door: Type: Bifold Width (m) 7.6 Height (m) 6. Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

12 6 LOCATION MAP LOADING FLOOR PLAN

13 6 DIMENSIONS Storage 6 W x D (m) 5.6m x 6.6m.8m x m.8m x 5m.8m x 8m.8m x 8m - No Ceiling Height 6m 6m 6m 6m 6m - - CAPACITIES Type of Vehicle Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) Skips Car Parking Not Allowed - Not Allowed - Main Door Way Not Allowed - 4 Main Door Way Not Allowed A move-in/move-out schedule is required to identify the loading dock schedule. FACILITIES AND FEATURES No. of bays 4 Floor Service Pit No Storage Space No Paging system Located in 7 Flooring Concrete Steel post Yes Security Access Yes Ramp No Toilets Male Levelers No Floor Load (weight in kg) Disability Access Yes Bumpers No HSE Fire extinguisher & hose Temperature Outdoor reel available Shutter switch Easy push button Other ancillary Paint wash room, transformer room, electrical room, battery charging Lighting Description Floodlights room/s room, waste recycle room Drive-on floor access points Yes Service Lift Service & Passanger Power Supply 8 x pin square outlet x amp outlet Freight Elevator Location Loading Side Capacity - Width m Height 4m Door (w).8m Door (h).6m DOORWAYS AND ENTRANCES Doorways and Entrances No. of Entrance/s (Excluding 0 Venue (s) serviced and Exhibition Hall 6 Dock Door) No. of Exit/s (Excluding Dock 0 accessible via this loading dock Door) Door: Type: Bifold Width (m) 6 Height (m) 4.4 Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

14 7 LOCATION MAP LOADING FLOOR PLAN

15 7 DIMENSION Storage 7 W x D (m) 8m x 0m.8m x 8m.8m x 8m.8m x 8m.8m x 8m.8m x 8m 7 SQ M Ceiling Height 0m 0m 0m 0m 0m 0m.8m CAPACITIES Type of Vehicle Floor Load Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) Skips Car Parking (weight in kg) Loadning Bay Not Allowed - Loadning Bay Not Allowed - Loadning Bay Main Door Way Not Allowed - Loadning Bay 4 Main Door Way Not Allowed - Loadning Bay 5 Main Door Way Not Allowed - FACILITIES AND FEATURES No. of bays 5 Floor Service Pit No Storage Space Yes () Paging system Yes Flooring Concrete Steel post Yes Security Access Yes Ramp No Toilets Male Levelers No Disability Access Yes Bumpers No HSE Fire extinguisher & hose reel available Temperature Outdoor Shutter switch Easy push button Other ancillary Paint wash room, transformer room, electrical room, battery charging room, room/s waste recycle room Lighting Description Floodlights Drive-on floor access points Yes Service Lift Service & Passanger Power Supply 8 x pin square outlet x amp outlet Freight Elevator Location Back Capacity - Width m Height 4m DOORWAYS AND ENTRANCES No. of Entrance/s (Excluding Dock Door) No. of Exit/s (Excluding Dock Door) Door (w).8m Door (h).6m Venue (s) serviced and accessible via this loading dock Exhibition Hall 7 Door: Type: Bifold Width (m) 7.6 Height (m) 6. Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

16 8 LOCATION MAP LOADING FLOOR PLAN

17 8 DIMENSIONS Storage 8 W x D (m) 8m x 0m.8m x 8m.8m x 8m.8m x 8m.8m x 8m.8m x 8m 00 SQ M Ceiling Height 0m 0m 0m 0m 0m 0m.8m CAPACITIES Type of Vehicle Floor Load Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) Skips Car Parking (weight in kg) Main Door Way Not Allowed - Main Door Way Not Allowed - Main Door Way Not Allowed - 4 Not Allowed - 5 Not Allowed - FACILITIES AND FEATURES No. of bays 5 Floor Service Pit No Storage Space Yes () Paging system Located in 9 Flooring Concrete Steel post Yes Security Access Yes Ramp No Toilets Male Levelers - Disability Access Yes Bumpers No HSE Fire extinguisher & hose Temperature Outdoor reel available Shutter switch Easy push button Other ancillary Paint wash room, transformer room, electrical room, battery charging room, Lighting Description Floodlights room/s waste recycle room Drive-on floor access points Yes Service Lift Service Power Supply 8 x pin square outlet x amp outlet Freight Elevator Location Back Capacity - Width m Height 4m Door (w).8m Door (h).6m DOORWAYS AND ENTRANCES No. of Entrance/s (Excluding Venue (s) serviced and Exhibition Hall 8 Dock Door) accessible via this loading No. of Exit/s (Excluding Dock dock Door) Door: Type :Bifold Width (m) 7.6 Height (m) 6. Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map

18 9 LOCATION MAP LOADING FLOOR PLAN

19 9 DIMANSIONS Storage 9 W x D (m) 8m x 0m.8m x 8m.8m x 8m.8m x 8m.8m x 8m.8m x 8m 0 SQ M Ceiling Height 0m 0m 0m 0m 0m 0m.8m CAPACITIES Type of Vehicle Floor Load Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) Skips Car Parking (weight in kg) Not Allowed - Not Allowed - Mian Door Way Not Allowed - 4 Main Door Way Not Allowed - 5 Main Door Way Not Allowed - A move-in/move-out schedule is required to identify the loading dock schedule. FACILITIES AND FEATURES No. of bays 5 Floor Service Pit No Storage Space Yes Paging system Yes Flooring Concrete Steel post Yes Security Access Yes Ramp No Toilets Male Levelers No Disability Access Yes Bumpers - HSE Fire extinguisher & hose reel available Temperature Shutter switch Easy push button Other ancillary Lighting Description Floodlights room/s Outdoor Drive-on floor access points Yes Service Lift Service Power Supply 8 x pin square outlet, x amp outlet Freight Elevator Location Back Capacity - Width m Height 4m Door (w).8m Door (h).6m DOORWAYS AND ENTRANCES No. of Entrance/s (Excluding Venue (s) serviced and Exhibition Hall 9 Dock Door) No. of Exit/s (Excluding Dock accessible via this loading dock Door) Door: Type :Bifold Width (m) 7.6 Height (m) 6. Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map Paint wash room, transformer room, electrical room, battery charging room, waste recycle room

20 Theatre LOCATION MAP LOADING FLOOR PLAN

21 Theatre DIMENSIONS Theatre Theatre Storage W x D (m) 4.4m x 9m 4.8m x 9m 4.8m x 9m 4.8m x 9m N/A Ceiling Height 4m 4m 4m 4m N/A CAPACITIES Type of Vehicle Floor Load (weight in kg) Cars Trucks (8-wheeler and below) Trucks (4-wheeler and above) N/A - N/A - N/A - A move-in/move-out schedule is required to identify the loading dock schedule. FACILITIES AND FEATURES No. of bays Floor Service Pit No Storage Space No Paging system No Flooring Fine polished concrete Steel post Yes Security Access Yes Ramp Yes ( ) Toilets No Levelers No Disability Access Yes Seals No HSE Fire extinguisher & fire hose reel available Temperature Controlled Shutter switch Easy push button Bumpers Yes Lighting Description Floodlights Other ancillary room/s Paint Wash Room Drive-on floor access points Yes Service Lift Service Power Supply 4 x pin square outlet, x amp outlet Freight Elevator Location Inside (Right) Capacity 4500 Floors - Width.4m Height.5m SDepth i d 6.7m DOORWAYS AND ENTRANCES No. of Entrance/s(Excluding Dock Door) No. of Exit/s(Excluding Dock Door) Door: a) Dock Door (from service road).5mw x 4mH Venue (s) serviced and accessible via this loading dock Theatre, Auditorium Type Shutter.5mW x 4mH.5mW x 4mH b) Side Door m x.4mh c) Inner roller shutter.7m Wx mh Put other notes here Please refer also to the following documents for more detailed information: (a) Floorplan (measurements and dimensions) (b) Guidelines & Procedures (c) Traffic Management Plan (d) QNCC route map.7m Wx mh.7mw x mh

Fire Safety In High Rise Building

Fire Safety In High Rise Building Fire Safety In High Rise Building CLASSIFICATION OF BUILDINGS AS PER NATIONAL BUILDING CODE 1. GROUPING. Group A - Residential : Lodgings, Dwellings, Dormitories, Flats, Hotels. Group B Group C - Educational

More information

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER 2013 1. CAPACITY. Stalls: 257 Seats per row: 22(Max)

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER 2013 1. CAPACITY. Stalls: 257 Seats per row: 22(Max) HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER 2013 1. CAPACITY Total: 490(Max) Stalls: 257 Seats per row: 22(Max) Balcony: 233 Seats per row: 24(Max) See section 11 for seat

More information

TO LET. 1 st FLOOR OFFICE SUITE. 204m_ (2,200 Sq Ft) KINGS COURT LEYLAND LOCATION

TO LET. 1 st FLOOR OFFICE SUITE. 204m_ (2,200 Sq Ft) KINGS COURT LEYLAND LOCATION TO LET 1 st FLOOR OFFICE SUITE 204m_ (2,200 Sq Ft) KINGS COURT LEYLAND LOCATION Leyland benefits from excellent transport links, with junction 28 of the M6 Motorway within 1 mile of the premises and the

More information

Lower Level (Level L) Exhibit Halls A, B & C

Lower Level (Level L) Exhibit Halls A, B & C Floor Plans Wal t e r E. Was h i n g ton Con v e n t i on C e n t e r Lower Level (Level L) Exhibit Halls A, B & C Lower Level (Level L) Lower Level (Level L) Halls A, B & C Hall A 151,000 square feet

More information

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Multilift PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: ASME A17.1 ASME A18.1 CSA B613 CSA B355-09 19-m01-2015 Part No. 000790 Copyright 2015 Savaria Corporation All rights reserved. Printed

More information

Lödige Goods Passenger Lifts

Lödige Goods Passenger Lifts Lödige Goods Passenger Lifts OLYMPUS-Series Goods Lifts TRAFFICO Car Lifts TECHNOLOGY IN MOTION Service Intralogistik Systems Machines Lifts Road Lödige Industries Technology in Motion The core competence

More information

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.

LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete. LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and

More information

ACCESSIBILITY STANDARD

ACCESSIBILITY STANDARD SCANDIC S ACCESSIBILITY STANDARD Here you can read our 135 point accessibility standard. It has been drawn up by carefully following the route taken by guests from the car park on through the whole hotel.

More information

Ministry of the Environment Decree. on housing design

Ministry of the Environment Decree. on housing design G1 THE NATIONAL BUILDING CODE OF FINLAND Housing Design Regulations and Guidelines 2005 Ministry of the Environment Decree on housing design adopted in Helsinki on the 1 st of October 2004 In accordance

More information

V1504 Vertical Platform Lift OWNER S MANUAL

V1504 Vertical Platform Lift OWNER S MANUAL V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 03-m12-2013 2 IMPORTANT Ensure that only an authorized Savaria Dealer

More information

TECHNICAL RIDER 2014-05-29

TECHNICAL RIDER 2014-05-29 TECHNICAL RIDER 2014-05-29 The following rider forms an integral part of the contract and its terms and conditions are therefor to be carried out in full. If you have any questions, or if any of the following

More information

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE Multilift (B613) VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: CSA B613 01-m06-2011 Part No. 000790 Copyright 2011 Savaria Corporation All rights reserved. Printed in Canada Purpose of this guide

More information

American Academy of Physical Medicine and Rehabilitation Site Survey Report

American Academy of Physical Medicine and Rehabilitation Site Survey Report American Academy of Physical Medicine and Rehabilitation Site Survey Report Introduction and Background In early 2013, the Contract Meeting Manager for the American Academy of Physical Medicine and Rehabilitation

More information

JEALOUS GALLERY POP UP EXHIBITION SPACE 53 CURTAIN ROAD SHOREDITCH LONDON EC2A 3PT

JEALOUS GALLERY POP UP EXHIBITION SPACE 53 CURTAIN ROAD SHOREDITCH LONDON EC2A 3PT JEALOUS GALLERY POP UP EXHIBITION SPACE 53 CURTAIN ROAD SHOREDITCH LONDON EC2A 3PT JEALOUS EAST +44(0)20 7739 4107 JEALOUS CROUCH END +44(0)20 8347 7688 LOUISE@JEALOUSGALLERY.COM 53 CURTAIN ROAD IS LOCATED

More information

All Weather Hall. Efficient, multipurpose & quick to build

All Weather Hall. Efficient, multipurpose & quick to build All Weather Hall Efficient, multipurpose & quick to build ALL WEATHER HALL www.deboer.com www.deboer.com ALL WEATHER HALL A flexible solution for a multitude of needs All Weather halls from De Boer provide

More information

STICKLEY AUDITORIUM RENOVATION Community and Stakeholder Presentation

STICKLEY AUDITORIUM RENOVATION Community and Stakeholder Presentation STICKLEY AUDITORIUM RENOVATION Community and Stakeholder Presentation APRIL 30, 2014 SCHEMATIC DESIGN PROGRESS Code Study Analysis: key issues and resolutions Seating Analysis of sightlines, seating and

More information

V1504 Vertical Platform Lift OWNER S MANUAL

V1504 Vertical Platform Lift OWNER S MANUAL V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 01-m03-2016 2 IMPORTANT Ensure that only an authorized Savaria Dealer

More information

CASEY.VIC.GOV.AU. Event Planning Guide

CASEY.VIC.GOV.AU. Event Planning Guide CASEY.VIC.GOV.AU Event Planning Guide About this guide The City of Casey (the Council) seeks to manage an events program to encourage and support our community and celebrate its diversity. This guide is

More information

Divadlo Inspirace (Ints-per-ats-zay)

Divadlo Inspirace (Ints-per-ats-zay) Divadlo Inspirace (Ints-per-ats-zay) Address Malostranské náměstí 13 Malá Strana, Praha 1 Nearest Metro - Malostranská (seven minutes walk) Trams - 12,20,22 to Malostranské náměstí (two minutes walk) Web

More information

INTERIM WASTE STORE OPERATING LICENCE DESCRIPTION OF THE STRUCTURES, COMPONENTS, SYSTEMS AND EQUIPMENT

INTERIM WASTE STORE OPERATING LICENCE DESCRIPTION OF THE STRUCTURES, COMPONENTS, SYSTEMS AND EQUIPMENT Interim Waste Store Operating Licence Application Document IWS-O-LA-FD (REDACTED VERSION) INTERIM WASTE STORE OPERATING LICENCE DESCRIPTION OF THE STRUCTURES, COMPONENTS, SYSTEMS AND EQUIPMENT (Rev. 1)

More information

Waste & Recycling. Planning Guidance on Waste & Recycling Storage and Collection. Development & Enterprise FOR INTERNAL USE ONLY.

Waste & Recycling. Planning Guidance on Waste & Recycling Storage and Collection. Development & Enterprise FOR INTERNAL USE ONLY. Waste & Recycling Planning Guidance on Waste & Recycling Storage and Collection October 2011 Development & Enterprise FOR INTERNAL USE ONLY Contents 01 Introduction 3 02 General guidelines 3 03 Individual

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m Main House Technical Specification Get In Access for loading and unloading is via St Stephen s goods yard into the Truck loading bay. Flat access at Stage Level for HGV s, backing directly onto main theatre

More information

BOOTH DESIGN RULES NEW! mgerald@eventsdc.com

BOOTH DESIGN RULES NEW! mgerald@eventsdc.com BOOTH DESIGN RULES All exhibits must conform to the dimensions outlined below in order to assure ease of movement of participants and clear lines of visibility in the exhibit hall. For more information

More information

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic Test Room ID: R21F Description: SEMI ANECHOIC SHIELDED TEST ENCLOSURE Primary Testing Uses: FCC, CE Mark Dimensions: 9.75m x 6.10m x 5.49m (32ft. x 20ft. x 18ft.) [see Figure 3 below] Construction: Galvanized

More information

AMS 120. EFT Guest Card Terminal & Refund unit

AMS 120. EFT Guest Card Terminal & Refund unit AMS 120 EFT Guest Card Terminal & Refund unit ACCOUNT MANAGEMENT STATIONS Wall mounted kiosk offering Visitor card purchase and refund Card deposit EFT purchase, refund and loading Full statement facilities

More information

Saferand easierinstallation

Saferand easierinstallation EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little

More information

Planning Information. Passenger and Freight Elevators.

Planning Information. Passenger and Freight Elevators. A company of ThyssenKrupp Elevator Thyssen Aufzüge tk This planning information will give you an overview of the most important planning criteria of passenger and freight elevators. However you should

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

STORAGE SPACE EFFICIENCY GUIDE A DEMONSTRATION IN SPACE

STORAGE SPACE EFFICIENCY GUIDE A DEMONSTRATION IN SPACE STORAGE SPACE EFFICIENCY GUIDE A DEMONSTRATION IN SPACE SAVING SPACE IS JUST THE BEGINNING Maximizing the efficiency and productivity of a facility is no simple task. With so many variables constantly

More information

Display Rules & Regulations CHFA WEST / CHFA EAST / CHFA QUEBEC

Display Rules & Regulations CHFA WEST / CHFA EAST / CHFA QUEBEC CHFA WEST / CHFA EAST / CHFA QUEBEC Display rules and regulations ensure that all exhibitors, regardless of exhibit size or location, enjoy an environment that is conducive to successful interaction with

More information

accessibility standard

accessibility standard Scandic s accessibility standard Here you can read our 110 point accessibility standard. It has been drawn up by carefully following the route taken by guests from the car park on through the whole hotel.

More information

Hanna delivers the technical and marketing expertise needed to produce a car wash that meets the car wash customer's expectations.

Hanna delivers the technical and marketing expertise needed to produce a car wash that meets the car wash customer's expectations. Planning a Car Wash Planning begins with examining customer preferences. A review of the latest consumer survey data (including the 2001 ICA Study of Consumer Carwashing Attitudes and Habits) indicates

More information

A59 A29 A16 A17 A58 Roosendaal

A59 A29 A16 A17 A58 Roosendaal www.prologis.com THE NETHERLANDS PROLOGIS PARk MOERDIjk Prologis Park Moerdijk, is a modern logistics platform located in the Tradepark of Port of Moerdijk and consists of three state-of-the-art distribution

More information

Automatic Door Selection Guide

Automatic Door Selection Guide Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment

More information

ACCESS AUDIT OF WESTPORT HOUSE

ACCESS AUDIT OF WESTPORT HOUSE ACCESS AUDIT OF WESTPORT HOUSE Large sign on the highway to indicate the entrance to Purbeck District Council Large and wide entrance Entrance showing sign for opening times Entrance sign Main entrance

More information

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015 HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015 May 2015 MAYOR OF LONDON Housing Standards: Transition Policy Statement. On 25 March 2015 through a written ministerial statement,

More information

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

TO: The Municipal Building Surveyor Telephone 5320 5650 City of Ballarat PO Box 655 BALLARAT VIC 3353

TO: The Municipal Building Surveyor Telephone 5320 5650 City of Ballarat PO Box 655 BALLARAT VIC 3353 APPLICATION FOR A DIVISION 2 OCCUPANC PERMIT (For a Place of Public Entertainment) Building Act 1993 BUILDING REGULATIONS 2006 Part 11, Regulation 1002 Form 5 TO: The Municipal Building Surveyor Telephone

More information

Stir it up! Risk Assessment Form

Stir it up! Risk Assessment Form YOUR DETAILS Host Organisation completing Assessment Venue for Activity Activity ID Assessment completed Name Phone Contact Name Organisation Email Phone Mobile Name Number and Street Suburb Stir it up!

More information

THE UNIVERSITY OF EDINBURGH George Square Library

THE UNIVERSITY OF EDINBURGH George Square Library THE UNIVERSITY OF EDINBURGH George Square Library Bookable Rooms Access Guide George Square Library University Of Edinburgh George Square Edinburgh EH8 9LJ http://www.ed.ac.uk/maps/buildi ngs/main-university-library

More information

Gazeley. Where You and Your Horses Safety Comes First. Coachbuilders Ltd. Designed and Manufactured in Newmarket, Suffolk, Great Britain

Gazeley. Where You and Your Horses Safety Comes First. Coachbuilders Ltd. Designed and Manufactured in Newmarket, Suffolk, Great Britain Gazeley Coachbuilders Ltd HORSEBOX MANUFACTURER Designed and Manufactured in Newmarket, Suffolk, Great Britain Where You and Your Horses Safety Comes First Gazeley Coachbuilders Ltd is a total family business.

More information

THE UNIVERSITY OF EDINBURGH. ECA Evolution House.

THE UNIVERSITY OF EDINBURGH. ECA Evolution House. THE UNIVERSITY OF EDINBURGH. ECA Evolution House. A GUIDE TO ACCESS AND FACILITIES. Address: ECA Evolution House, 78 West Port, Edinburgh, E,H,1 2,L,E. Telephone number: 0131 651 5800. Campus map link:

More information

THE UNIVERSITY OF EDINBURGH, Alexander Graham Bell Building, King s Buildings,

THE UNIVERSITY OF EDINBURGH, Alexander Graham Bell Building, King s Buildings, THE UNIVERSITY OF EDINBURGH, Alexander Graham Bell Building, King s Buildings, A GUIDE TO ACCESS AND FACILITIES, Address Alexander Graham Bell Building, University of Edinburgh. King s Buildings. Edinburgh,

More information

MIDDLE SCHOOL INSTRUCTIONAL FORM. 1. To understand that music is and always has been an integral part of the human experience.

MIDDLE SCHOOL INSTRUCTIONAL FORM. 1. To understand that music is and always has been an integral part of the human experience. MIDDLE SCHOOL INSTRUCTIONAL FORM Area: Music Kathleen Sanz (Chairman) I. PROGRAM PHILOSOPHY See District Philosophy II. PROGRAM GOALS 1. To understand that music is and always has been an integral part

More information

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance UniSas BA Physical single-person detection Manual Attack Resistance Ballistic Resistance Access Flow Emergency exit Recyclable product Energy savings Eco-design Models: UniSas BA9, UniSas BA12 Physical

More information

THE UNIVERSITY OF EDINBURGH OLD COLLEGE

THE UNIVERSITY OF EDINBURGH OLD COLLEGE THE UNIVERSITY OF EDINBURGH OD COEGE A GUIDE TO ACCESS AND FACIITIES Old College University of Edinburgh Old College South Bridge Edinburgh EH8 9Y Phone 0131 650 2008 http://www.ed.ac.uk/maps Disabled

More information

Waste management guidance notes for residential developments

Waste management guidance notes for residential developments Waste management guidance notes for residential developments February 2014 www.southwark.gov.uk This document provides guidance on the waste storage and collection requirements that should be considered

More information

SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete

SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT 1. CONSTRUCTION: Foundation Super Structure Internal Walls External Walls Roof Retaining Walls RCC footing RCC Framed Structure confirming with zone II seismic

More information

Example risk assessment for a warehouse

Example risk assessment for a warehouse Example risk assessment for a warehouse Setting the scene The warehouse manager carried out a risk assessment of the warehouse. The warehouse employed 12 staff, some were part of a union. How was the risk

More information

GenStore Archive Cabinet

GenStore Archive Cabinet GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4

More information

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Fire. The Fire Installers Mate. A guide to fire alarm systems design Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects

More information

THE UNIVERSITY OF EDINBURGH. Alexander Graham Bell Building. King s Buildings

THE UNIVERSITY OF EDINBURGH. Alexander Graham Bell Building. King s Buildings THE UNIVERSITY OF EDINBURGH Alexander Graham Bell Building King s Buildings A GUIDE TO ACCESS AND FACILITIES Alexander Graham Bell Building King s Buildings Edinburgh EH93JF United Kingdom http://www.ed.ac.uk/maps/buildings/

More information

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options. A solution for making all premises accessible KONE Motala 2000 The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options. This

More information

Exhibitor/Client Rules and Regulations

Exhibitor/Client Rules and Regulations Advertising Authority for Logo Prior written approval is required for the use of the logotype, trademarks, symbols or trade name of BINGEMANS or any of the BINGEMANS brands including but not limited to

More information

Cost-effective solutions for all applications.

Cost-effective solutions for all applications. Professional Pressure Washers Hard Surface Cleaners NEW Cost-effective solutions for all applications. Pressure washer performance for hard-surfaces. Pressure washer performance made easy. Kärcher hard-surface

More information

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS Upgrading the PRS datacentres: space requirement S. S. Mathur, GM-IT, CRIS PRS / UTS scenario: then and now Year 2000 PRS: 600 locations UTS: 0 locations Year 2008 PRS 1600 locations E-ticketing Passengers

More information

S WORK CATALOGUE FAA29100H_BWC

S WORK CATALOGUE FAA29100H_BWC MACHINE ABOVE - 2, m/s BUILDER S WORK CATALOGUE FAA29100H_BWC 07-04-15 Version: a-e 800 kg 0 kg Otis Elevator Company 2007, All rights reserved MAIN 2/38 This catalogue summarizes useful information for

More information

San Diego Convention Center Floor Plans

San Diego Convention Center Floor Plans San Diego Convention Center Floor Plans A perfect meeting destination Our building is one of the world s most modern and technologically sophisticated convention and meeting facilities. To help you plan

More information

Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May

Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May Instruction To carry out Inspection of the Industrial Unit, to identify areas of repair to the Unit at commencement of the Lease.

More information

Section 6. Off-street Bicycle Space Regulations

Section 6. Off-street Bicycle Space Regulations Section 6 Off-street Bicycle Space Regulations 6.1 Number of Bicycle Spaces 6.1.1 General Requirements Unless otherwise provided in Schedule C or a CD-1 By-law, in all districts, the number of spaces required

More information

A U T O M O T I V E L I F T S

A U T O M O T I V E L I F T S Q U A L I T Y Y O U E X P E C T AT A P R I C E Y O U W O U L D N T T H E S TA N D A R D I N I N F O R M AT I O N, E Q U I P M E N T A N D D I A G N O S T I C S S Y S T E M S h t t p : / / d i a g n o s

More information

1 ELGOTEAM ADVANCED SECURITY SYSTEMS Bi-directional spike barrier. Bi-directional spike barrier Customer Information packet

1 ELGOTEAM ADVANCED SECURITY SYSTEMS Bi-directional spike barrier. Bi-directional spike barrier Customer Information packet 1 Customer Information packet For more information: info@elgoteam.com www.elgoteam.com 2 Chapter contents Subject Page number The company 3 Background 4 Applications 5 Advantages 6 Operating positions

More information

Proposed First Floor. Tennis Courts. Shower 3. Changing. Loft space for Plant. Changing 1 Changing 2. Store 2 Scouts Camping Equipment.

Proposed First Floor. Tennis Courts. Shower 3. Changing. Loft space for Plant. Changing 1 Changing 2. Store 2 Scouts Camping Equipment. Tennis Courts 950 050 1776 1106 4988 950 11220 wc wc wc wc 2785 710 Outside store Unisex Toilets 6970 Loft Hatch With ladder Access to plant Multi purpose hall 1 Up Entrance to changing rooms & fire exit

More information

Call 0871 334 1919 (option 2) conferenceandevents@leedsunited.com

Call 0871 334 1919 (option 2) conferenceandevents@leedsunited.com Conference & Event Suites CO N F E R E N C E & E V E N T S Nicky chapman suite The Nicky Chapman Suite is a large suite and can cater for parties of up to 500. It has natural daylight, air conditioning,

More information

FIRE DETECTION AND ALARM

FIRE DETECTION AND ALARM Scope Provide a fire alarm system, or expand the existing system, as required by Code, the requirements in the Special Instructions to Designers (SID) of the Design Guidelines, and/or as noted in the Program

More information

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014 Approved Document M: Part M Access to and use of buildings Volume 1 dwellings Consultation draft August 2014 i Main changes in the 2014 edition This approved document supports Requirements M4(1), M4(2)

More information

Disabled Access Guide

Disabled Access Guide Disabled Access Guide The Royal Hotel South Parade Weston-Super-Mare Somerset BS23 1JP Tel: 01934 423 100 Fax : 01934 415 135 Email: Web: reservations@royalhotelweston.com www.royalhotelweston.com Location

More information

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov

City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov City of Riverside Building & Safety Division Phone: (951) 826-5697 www.riversideca.gov BUILDING CODE REQUIREMENTS FOR CHILD DAY CARE The purpose of this document is to provide the user with a basic level

More information

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

ITEM DESCRIPTION SPECIFICATION TENDER OFFER TECHNICAL SPECIFICATIONS PL1 & PL2 PLEASE TICK IF YOU COMPLY. SPECIFY YOUR OPTION IF YOU DON'T. ITEM DESCRIPTION SPECIFICATION TENDER OFFER Make (please specify) 1.0 Type Duplex Passenger Lift 2.0 Minimum

More information

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau g GUIDELINE FOR SAFETY REQUIREMENTS FOR HAUNTED HOUSES PURPOSE This guide is intended to provide safety standards and regulations for the construction

More information

MANAGEMENT SOLUTION (P.A.M.S.)

MANAGEMENT SOLUTION (P.A.M.S.) DOORKING SYSTEMS ACCESS CONTROL SOLUTIONS PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Revision N, updated 01.12 PERIMETER ACCESS MANAGEMENT SOLUTION (P.A.M.S.) Design Concept How the System Works TYPICAL

More information

Electric Forklift Trucks Capacity 5000 and 6000 lbs. RX60-25C and RX60-30C SERIES RX60

Electric Forklift Trucks Capacity 5000 and 6000 lbs. RX60-25C and RX60-30C SERIES RX60 Electric Forklift Trucks Capacity 5000 and 6000 lbs. RX60-25C and RX60-30C SERIES RX60 Safety To adapt to different operating conditions and customer requirements, all performance parameters are adjustable.

More information

ridgway office ParK progress WAy, denton, manchester, m34 2gp

ridgway office ParK progress WAy, denton, manchester, m34 2gp Home ridgway House millenium House availability site PLaN gallery LocaTioN contact ridgway office ParK progress WAy, denton, manchester, m34 2gp To LeT / may sell To LeT HIgH QuALITy, AIR CondITIonEd offices

More information

Refuse and Recycling Advice note For Developers. September 2015

Refuse and Recycling Advice note For Developers. September 2015 Refuse and Recycling Advice note For Developers Contents: September 2015 1.0 Refuse and recycling Background Information 1.1 Introduction 2.0 Planning and design 2.1 Good Practice 2.2 Internal storage

More information

Emergency Response Guide

Emergency Response Guide Emergency Response Guide Honda CNG Vehicle Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc. Contents Key Components 1

More information

Decree of the Ministry of the Environment. on fire safety of garages

Decree of the Ministry of the Environment. on fire safety of garages E4 THE NATIONAL BUILDING CODE OF FINLAND Fire safety of garages Guidelines 2005 Decree of the Ministry of the Environment on fire safety of garages Adopted in Helsinki, 22 March 2005 Pursuant to the Decision

More information

Accessibility Design Advice

Accessibility Design Advice Accessibility Design Advice Quick Access Guide Improving the accessibility of the physical environment Websites It is good practise to provide written information on your web site for disabled visitors

More information

Ministry of the Environment Decree on accessible building

Ministry of the Environment Decree on accessible building F1 THE FINNISH BUILDING REGULATIONS 1 Barrier-free Building Regulations and 2005 Ministry of the Environment Decree on accessible building adopted in Helsinki on the 1 st of October 2004 In accordance

More information

Introduction. Meeting Spaces. Hynes Audio Services

Introduction. Meeting Spaces. Hynes Audio Services a ud i o / v i d e o c o n t r a c t o r a n d v e n d o r g u i d e Introduction Welcome to the John B. Hynes Veterans Memorial Convention Center (Hynes). The Massachusetts Convention Center Authority

More information

Switch. Building technology for the real world.

Switch. Building technology for the real world. Switch Building technology for the real world. S A F E S I M P L E S U S T A I N A B L E Technology that s designed to work for you. Special power requirements. Subcontractor s schedules. Frequent power

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

Waste & Recycling Container, Storage and Vehicle Access Requirements

Waste & Recycling Container, Storage and Vehicle Access Requirements Waste & Recycling Container, Storage and Vehicle Access Requirements PLEASE NOTE: This information is intended to provide overview guidelines for University of Edinburgh staff and contractors only. Exact

More information

Squash Court Design general points

Squash Court Design general points Squash Court Design general points Contents: Contents:... 1 1. Squash Court Dimensions... 2 2. CourtTech Walls... 3 3. Dimensional requirements for courts with CourtTech Walls... 3 4. Loading of CT System

More information

MILLENNIUM HOUSE TO LET / MAY SELL RIDGWAY OFFICE PARK, DENTON, M34 2SY

MILLENNIUM HOUSE TO LET / MAY SELL RIDGWAY OFFICE PARK, DENTON, M34 2SY TO LET / MAY SELL MILLENNIUM HOUSE RIDGWAY OFFICE PARK, DENTON, M34 2SY High quality, air conditioned offices with extensive on-site car parking immediately available from 2,500 to 15,000 sq ft MILLENNIUM

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

FOR RENT PRODUCTION AND COMMERCIAL FACILITIES ALONG WITH A SOCIAL AND OFFICE SURFACE MARR BUSINESS PARK 10 NAD DRWINĄ STREET IN KRAKÓW

FOR RENT PRODUCTION AND COMMERCIAL FACILITIES ALONG WITH A SOCIAL AND OFFICE SURFACE MARR BUSINESS PARK 10 NAD DRWINĄ STREET IN KRAKÓW FOR RENT PRODUCTION AND COMMERCIAL FACILITIES ALONG WITH A SOCIAL AND OFFICE SURFACE MARR BUSINESS PARK 10 NAD DRWINĄ STREET IN KRAKÓW JULY 2012 NEW PRODUCTION AND COMMERCIAL FACILITIES FOR RENT The production

More information

RATCLIFF PASSENGER LIFTS

RATCLIFF PASSENGER LIFTS RATCLIFF PASSENGER LIFTS A RANGE OF USER FRIENDLY LIFTS PROVIDING SAFE WHEELCHAIR ACCESS PASSENGER LIFT RANGE RATCLIFF UNDERFLOOR LIFTS - RUL350A - 350KG CAPACITY SUITABLE FOR COACH BUILT BODIES, IVECO

More information

New College. School Of Divinity.

New College. School Of Divinity. THE UNIVERSITY OF EDINBURGH. New College. School Of Divinity. A GUIDE TO ACCESS AND FACILITIES. Address New College. School of Divinity. University Of Edinburgh. 1 Mound Place. Edinburgh. E,H,1, 2,L,U,.

More information

Unit 15: Measurement Length, Area and Volume

Unit 15: Measurement Length, Area and Volume Unit 15: Measurement Length, Area and Volume Section A: Circumference measuring the circumference of a round object. You will to show all of your working out. C 5 d where: C 5 circumference 5 3.14 d 5

More information

Emergency Response Guide

Emergency Response Guide Emergency Response Guide Honda Natural Gas Vehicles This publilcation covers these Civic Natural Gas Models: 1998-2000 2001-2005 2006-2011 2012 Prepared for Fire Service, Law Enforcement, Emergency Medical,

More information

OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes. 1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310

More information

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management. AIMS is Malaysia and South East Asia s leading carrier neutral data centre operator and managed services provider. We provide international class data storage and ancillary services, augmented by an unrivaled

More information

Datacenter Site Selection Checklist

Datacenter Site Selection Checklist Checklist Use this checklist to aid in the process of selecting a new site for the data center. When visiting potential building sites, print the checklist off and take it along to record impressions and

More information

Waste Oil Handling, Spill Containment & Lighting

Waste Oil Handling, Spill Containment & Lighting 58 Waste Oil Handling, Spill Containment & Lighting 372000 SAMOA Mobile Waste Oil Drainer & Extractor Drains and/or extracts waste oil from cars and light commercial vehicles Drain bowl capacity of 20

More information

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012 Medicine Hat Fire Department Special Event Requirements August 202 medicinehat.ca/fire The following is a standard guide for event organizers to ensure occupant safety and compliance with the Alberta Fire

More information

Logistics Warehouse. Janco Logistics (HK) Ltd. DSC Services

Logistics Warehouse. Janco Logistics (HK) Ltd. DSC Services Logistics Warehouse DSC Services Receiving from local/overseas suppliers Storage of goods Inventory management Pick / Pack Process Re-packaging Barcode scanning Labeling Professional Logistics Warehouse

More information

GROUND OPERATIONS MANUAL

GROUND OPERATIONS MANUAL 1 05/03 1.0. Airbus A320/A321 Contents 1. Aircraft Dimensions and Vertical Clearances 3 2. Airplane Servicing Arrangement A320/A321 4 3. Service Points A320/A321 5 4. Description of Cargo Compartments

More information