Richard Cymler Building Consultancy

Size: px
Start display at page:

Download "Richard Cymler Building Consultancy"

Transcription

1 1 Lancaster Circus Queensway Birmingham B4 7DJ Richard Cymler Building Consultancy Telephone :

2 Changes To The 2015 Building Regulations Introduction What s Changing in October 2015 Approved Document E Approved Document G Approved Document H Approved Document M1 and M2 Approved Document Q Transitional Period Questions

3 Introduction "Helping clients achieve optimal value, quality and innovation" Acivico Building Consultancy Ltd Formed in 2012 Responded to client needs Employed additional staff to meet demand Graduate training programme Acivico Building Consultancy is now also an Approved Inspector! This means we can offer a service tailored to our customers requirements anywhere within the England. Alongside our usual LABC Partnership work anywhere within England and Wales

4 What s Changing in October 2015? Following the Housing Standards Review, which aimed to simplify local requirements and standards, the Building Regulations have been amended in order drive these changes. The Building Regulations that have been amended are :- Approved Document E Approved Document G Approved Document H Approved Document M1 Approved Document M2 Approved Document Q One of the most unique decisions made from the Housing Standards Review is the introduction of new dual level Building Regulations in relation to Water and Access. (Approved Document G and M)

5 Approved Document E In force since 6 th April. Building Bulletin 93 : Acoustic design of schools performance standards Compliance is to be shown by either Drawings, plans and specification in accordance with the new design guide or a written report by a specialist acoustic consultant, however this approach has to be agreed by the client.

6 Approved Document E Previously the document referred to refurbishment works and stated such work should incorporate upgrading of the acoustics as appropriate however with only db values of new build to refer to. In general within the revised document refurbishment works have to achieve a standard that is 5dB less than that of a new build. Although it is also clearer that this is a recommendation and not a requirement of the Building Regulations.

7 Approved Document G This is the first of the Building Regulations to have a dual level! The changes to Approved Document G start with the introduction of more onerous water efficiency (Regulation 36). This means that the planning authority can impose an increased water efficiency rate for the consumption of wholesome water, from 125 litres per person per day to 110 litres. This is dependant on the local plan and suitability. Regulation 37 requires a notice to be given to the Building Control Body that specifies the water consumption target for the specific dwelling as well as the calculated consumption for that dwelling. This must be submitted no later than 5 days after the completion of the dwelling. Also when submitting the application, the applicant must specify the required water consumption required imposed by the local plan.

8 Approved Document G The next key change in the amended document is the introduction of the fittings approach. This can be used as an alternative to the Water Efficiency calculations. Where the fittings approach is used, the water consumption of the fittings must not exceed the values given in Table 2.1. When this approach is used the notice given under Regulation 37 must state less than 125 litres per persons per day using the fittings approach

9 Approved Document G The Fittings Approach can be still be used as an alternative to the Water Efficiency calculations with the optional higher efficiency requirements. Where the fittings approach is used with the optional higher efficiency requirements, the water consumption of the fittings must not exceed the values given in Table 2.2. When this approach is used the notice given under Regulation 37 must state less than 110 litres per persons per day using the fittings approach

10 Approved Document G Appendix A now shows the water efficiency calculator methodology. This methodology includes a few minor amendments such as the removal of any references to the code for sustainable homes, and also some minor alterations from the European efficiency labelling. The annex listing the relevant competent person self-certification schemes has been deleted. This is as a result of the new and amended competent Persons Scheme.

11 Approved Document H The Changes to this Document are fairly minor. The first change to this document is a minor alteration to H3, it is an amendment of the limits of application of the requirement (Rainwater drainage) following the amendments to Approved Document M in The Second change is additional guidance on solid waste storage in H6 and updated references.

12 Approved Document H The Additions to Approved Document H is as follows :- Paragraph 1.13 states external waster storage design should be carefully considered where it is in a public place or open area. Reference is now made to the NHBC Foundation good practice guidance on external waste storage Ref NF60 Paragraph 0.3 makes clear that the provision in H6 also apply where there is a change of use E.G. House to flats.

13 Approved Document M1 This Document has changed significantly in respect of new housing. Firstly Approved Document M Has now been divided in to M1 (for Dwellings) and M2 (Buildings other than Dwellings). Also as a result of the Dual Level Building Regulations Approved Document M1 is now split in to three separate sections :- Section 1 Category 1 Visitable Dwellings Section 2 - Category 2 Assessable and adaptive Dwellings Section 3 - Category 3 Wheelchair user Dwellings

14 Approved Document M1 Section 1 Category 1 Visitable Dwellings

15 Approved Document M1 Section 1 Category 1 Visitable Dwellings This is similar to the previous version of approved document M in terms of new dwellings however the guidance goes into greater detail. When determining suitable access for Category 1 dwellings compliance with the Regulations is achieved if you provide the following :-

16 Approved Document M1

17 Approved Document M1 Section 2 Category 2 Accessible and Adaptive Dwellings This is the next tier of the Optional Regulations

18 Approved Document M1 Section 2 Category 2 Accessible and Adaptive Dwellings This regulation will be satisfied if the following are achieved : -

19 Approved Document M1 Section 2 Category 2 Accessable and Adaptive Dwellings

20 Approved Document M1 Section 2 Category 2 Accessable and Adaptive Dwellings

21 Approved Document M1

22 Approved Document M1

23 Approved Document M1 Section 3 Category 3 Wheelchair User Dwellings

24 Approved Document M1 Section 3 Category 3 Wheelchair User Dwellings This regulation will be satisfied if the following is achieved : -

25 Approved Document M1 Section 3 Category 3 Wheelchair User Dwellings

26 Approved Document M1 Section 3 Category 3 Wheelchair User Dwellings

27 Approved Document M1 Section 3 Category 3 Wheelchair User Dwellings

28 Approved Document M2 Approved Document M2 deals with Buildings other than dwellings in relation to access to and use of Buildings. However aside from being separated from the section dealing with dwellings there have been no changes to this document.

29 Approved Document Q This completely new Approved Document relates to Security in Dwellings. What the regulations require :-

30 Approved Document Q How do you meet the requirement? Requirement Q1 Applies to accessible Doors and Windows that provide easy access in any of the following circumstances :- 1. Into a dwelling from outside. 2. Into parts of a Building containing a flat from outside. 3. Into a flat from common parts of the Building. Regulation Q1 will be satisfied if Windows and doors can resist physical attack by casual or opportunist burglars by being both:- 1. Sufficiently Robust. 2. Fitted with appropriate Hardware.

31 Approved Document Q Doorsets *including garage doorsets if the garage provides access to the dwelling, and communal entrance doorsets. Doors should be manufactured to designs that have been shown to meet the security requirements of British Standards Publications PAS 24:2012 (or a similar or better standard) or designed and manufactured in accordance with Appendix B (Bespoke Timber Secure Doorsets). Letter plates should be restricted to 260mm x 40mm and be positioned or designed to prevent people using this as a means of access. ( i.e. placing hands or objects through to obtain keys). Main doors for entering a dwelling should contain a viewer or other means of seeing a caller. Frames:- Should be mechanically fixed to the structure of the building in accordance with manufacturers instructions. Light weight walls should incorporate a resilient layer

32 Approved Document Q Windows Ground floor, Basement and easily accessible windows should be secure windows. Windows should be manufactured to designs that have been shown to meet the security requirements of British Standards Publications PAS 24:2012 (or a similar or better standard). Should be mechanically fixed to the structure of the building in accordance with manufacturers instructions.

33 Transitional period For the changes to Approved Documents G,H.M1 & M2 Any works commenced or subject to a Full Plans Application, Building Notice or Initial Notice on or after to the 1 st October 2015 will be subject to the new 2015 Regulation. For the new Approved Document Q Any works with a Full Plans Application, Building Notice or Initial Notice submitted prior 1 st October 2015 will not be subject to this new regulation providing the works are commenced prior to 1 st October Commencement of work In the case of Approved Document Q which is subject to transitional provisions. In the opinion of DCLG the commencement of work would be considered as one of the following: excavation for strip or trench foundations or for pad footings; digging out and preparation of ground for raft foundations; Vibro-floatation (stone columns) piling, boring for piles or pile driving; drainage work specific to the building(s) concerned.

34 Transitional period DCLG consider that the following types of work would not be constitute the commencement of work: removal of vegetation demolition of any previous buildings on the site; removal of top soil; removal or treatment of contaminated soil; excavation of trial holes; dynamic compaction; general site servicing works (e.g. roadways) In most cases applications will be for housing sites with a number of new dwellings. In such cases it is the date of commencement of work on the site (i.e. on the first dwelling) which determines whether the transitional provisions are applicable to all dwellings included in the application.

35 Any Questions?

Approved Document Q: Security

Approved Document Q: Security Approved Document Q: Security Requirement Q1 Unauthorised access Consultation draft September 2014 1 The approved documents What is an approved document? The Secretary of State has approved a series of

More information

Security Dwellings. The Building Regulations 2010. 2015 edition for use in England* ONLINE VERSION APPROVED DOCUMENT ONLINE VERSION

Security Dwellings. The Building Regulations 2010. 2015 edition for use in England* ONLINE VERSION APPROVED DOCUMENT ONLINE VERSION The Building Regulations 2010 Security Dwellings APPROVED DOCUMENT Q Q1 Unauthorised access 2015 edition for use in England* The 2015 Edition This approved document supports requirement Q1 of Schedule

More information

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 E1 E2 E3 E4 E Protection against sound from other parts of the building and adjoining buildings Protection against

More information

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Building over or close to a public sewer

Building over or close to a public sewer Building over or close to a public sewer thameswater.co.uk/developerservices thameswater.co.uk/developerservices 1 Questions and answers Did you know Thames Water is legally responsible for more than 100,000

More information

Geotechnical Building Works (GBW) Submission Requirements

Geotechnical Building Works (GBW) Submission Requirements Building Control (Amendment) Act 2012 and Regulations 2012: Geotechnical Building Works (GBW) Submission Requirements Building Engineering Group Building and Construction Authority May 2015 Content : 1.

More information

THE TOWN AND COUNTRY PLANNING ACT 1990 Grant of Planning Permission

THE TOWN AND COUNTRY PLANNING ACT 1990 Grant of Planning Permission Civic Offices Havant Hampshire PO9 2AX Tel (023)9247 4174 Fax(023)9244 6588 DX50005 Havant www.havant.gov.uk To: ADP Architects Ltd Richmond Court 94 Botley Road Park Gate Southampton, Hants SO311BA For:

More information

An offer to extend Right to Buy discounts to housing association tenants

An offer to extend Right to Buy discounts to housing association tenants An offer to extend Right to Buy discounts to housing association tenants This document sets out the terms of an offer the National Housing Federation has made to the Government for a potential agreement

More information

APPLICATION TO CONDUCT A VETERINARY HOUSE CALL PRACTICE (Small Animals)

APPLICATION TO CONDUCT A VETERINARY HOUSE CALL PRACTICE (Small Animals) VETERINARY SURGEONS BOARD OF QUEENSLAND APPLICATION TO CONDUCT A VETERINARY HOUSE CALL PRACTICE (Small Animals) Veterinary Surgeons Board Approval Application Pack A Veterinary House Call Practice offers

More information

Application for a water connection to a commercial or mixed use development

Application for a water connection to a commercial or mixed use development Application for a water connection to a commercial or mixed use development Providing clean, safe water: It s part of our Blueprint for Yorkshire Your application form for a water connection to a commercial

More information

Asbestos at work guide

Asbestos at work guide Asbestos at work guide Contents Introduction.... 2 Frequently asked questions.... 4 The Control of Asbestos Regulations 2006... 5 Types of asbestos survey.... 7 1 Introduction This document provides a

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

Thames Water is pleased to comment on the proposed changes to the London Plan 2014.

Thames Water is pleased to comment on the proposed changes to the London Plan 2014. Boris Johnson Mayor of London (London Plan) Greater London Authority City Hall More London The Queen s Walk London SE1 2AA Thames Water Property Services Your ref Our ref Name Phone Email London Plan Review

More information

Building Control Guidance Note

Building Control Guidance Note Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material

More information

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION -SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION -Unit number- 4420798 -Unit title- CONSTRUCTION TECHNOLOGY 2: SUBSTRUCTURE AND REMEDIAL WORKS -Superclass category-

More information

Welcome to a warmer home. You could qualify for: www.ieservices.org.uk. Your guide to a gas supply and central heating system

Welcome to a warmer home. You could qualify for: www.ieservices.org.uk. Your guide to a gas supply and central heating system Welcome to a warmer home Your guide to a gas supply and central heating system You could qualify for: Up to 2,404 towards the cost of connecting gas to your home Up to 1,300 towards new gas central heating

More information

Electrical safety Dwellings

Electrical safety Dwellings The Electrical safety Dwellings APPROVED DOCUMENT P1 P Design and installation of electrical installations 2013 edition for use in England* Main changes in the 2013 edition This approved document supports

More information

Construction and Demolition Waste

Construction and Demolition Waste Re-issued under new categorization in August 2009 as Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers ADV-19 Buildings Department Practice Note

More information

Guide to the safe installation of downlighters in dwellings

Guide to the safe installation of downlighters in dwellings Guide to the safe installation of downlighters in dwellings Technical guidance for designers and installers 01 Guide to the safe installation of downlighters in dwellings Technical guidance for designers

More information

South East Region Leakage Code of Practice. Affinity Water Limited CODE OF PRACTICE ON LEAKAGE

South East Region Leakage Code of Practice. Affinity Water Limited CODE OF PRACTICE ON LEAKAGE 1 of 13 Affinity Water Limited CODE OF PRACTICE ON LEAKAGE LEAKAGE FROM DOMESTIC CUSTOMERS WATER SUPPLY PIPES Dated: 10 July 2014 1 INTRODUCTION 2 of 13 The Company is committed to a policy of water efficiency

More information

Designing Out Crime Assessment

Designing Out Crime Assessment Designing Out Crime Assessment New Flats (Affordable Housing) Yew Tree Road Moreton Wirral CH46 8UA Construction of flats complex. For Bernard Taylor Partnership Ltd o.iu@bernardtaylor.co.uk Tel 0161 443

More information

QS 004 DEPARTMENT OF PUBLIC WORKS REPUBLIC OF SOUTH AFRICA BUILDING COST DATABASE

QS 004 DEPARTMENT OF PUBLIC WORKS REPUBLIC OF SOUTH AFRICA BUILDING COST DATABASE DEPATMENT OF PUBLIC WOKS EPUBLIC OF SOUTH AFICA BUILDING COST DATABASE AUGUST 2012 DEPATMENT OF PUBLIC WOKS EPUBLIC OF SOUTH AFICA BUILDING COST DATABASE POJECT DATA SHEET NOTE Bills of Quantities Stage

More information

Rotherham Metropolitan Borough Council

Rotherham Metropolitan Borough Council Rotherham Metropolitan Borough Council Town and Country Planning Act 1990 Eton Construction Ltd Mr P Harris 79a Wellgate Rotherham S60 2LZ Reference RB2014/1538 Decision Date 08 January 2015 Description

More information

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015 HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015 May 2015 MAYOR OF LONDON Housing Standards: Transition Policy Statement. On 25 March 2015 through a written ministerial statement,

More information

Aggregates for Path Construction

Aggregates for Path Construction Aggregates for Path Construction Technical Information Note No. 7 October 2011 About Sustrans Sustrans makes smarter travel choices possible, desirable and inevitable. We re a leading UK charity enabling

More information

Elevating Your House. Introduction CHAPTER 5

Elevating Your House. Introduction CHAPTER 5 CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,

More information

Fire Doors The Role of a Fire Door

Fire Doors The Role of a Fire Door Fire Doors The Role of a Fire Door BWF-Certifire Fire Door and Doorset Scheme Presented by John Fletcher John Fletcher Consulting Ltd. Fire doors main messages 1. Fire doors are essential in passive fire

More information

Basements and Deep Building Construction Policy 2014

Basements and Deep Building Construction Policy 2014 Basements and Deep Building Construction Policy 2014 APPROVAL Council / CEO 27 October 2014 VERSION NO: Version 1.0 TRIM REF: 14/67838 REVIEW 30/10/2019 RESPONSIBLE EXECUTIVE General Manager City Assets

More information

Risk assessment decision making tool for building control bodies. Final risk assessment guidance

Risk assessment decision making tool for building control bodies. Final risk assessment guidance Risk assessment decision making tool for building control bodies Final risk assessment guidance Risk assessment decision making tool for building control bodies Final risk assessment guidance Greenstreet

More information

symptoms of a faulty foundation

symptoms of a faulty foundation symptoms of a faulty foundation How does drought impact your home's foundation? For many Texas families, their home becomes the single largest investment and also the family fortune. The home's foundation

More information

Guidance on loft conversions in two-storey houses

Guidance on loft conversions in two-storey houses Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for

More information

Standards Committee T echnical Technical Conference

Standards Committee T echnical Technical Conference Standards Committee Technical Conference Agenda Overview of claims costs Years 0 2 claims and resolutions Years 3 10 claims What are we commonly seeing now? An example of what we might see in future? Summary

More information

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE

SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE SEPTIC TANKS FOR THE COLLECTION & SETTLEMENT OF DOMESTIC SEWAGE Let us help! Free professional site visit with friendly support and advice. helpingyou@klargester.com to make the right decision or call

More information

If stepping is required, step at 180mm as seen in this picture.

If stepping is required, step at 180mm as seen in this picture. Cast Foundations to standard building regulations requirements. Foundations must be cast completely level, 600mm wide by 230mm deep for single storey, double storey is not allowed by NHBRC. If stepping

More information

Procedural Guide. Planning appeals - England

Procedural Guide. Planning appeals - England Procedural Guide Planning appeals - England This Guide applies to o planning appeals; o householder development appeals; o minor commercial appeals; o listed building appeals; o advertisement appeals;

More information

Protection from falling. collision and impact. The Building Regulations 2010. 2013 edition for use in England* ONLINE VERSION APPROVED DOCUMENT

Protection from falling. collision and impact. The Building Regulations 2010. 2013 edition for use in England* ONLINE VERSION APPROVED DOCUMENT The Protection from falling, collision and impact APPROVED DOCUMENT K1 K2 K3 K4 K5 K Stairs, ladders and ramps Protection from falling Vehicle barriers and loading bays Protection against impact with glazing

More information

Ward: Purley DELEGATED BUSINESS MEETING Lead Officer: Head of Planning Control week of 23/03/2009

Ward: Purley DELEGATED BUSINESS MEETING Lead Officer: Head of Planning Control week of 23/03/2009 Ward: Purley DELEGATED BUSINESS MEETING Lead Officer: Head of Planning Control week of 23/03/2009 Application No. 09/00389/LP - 51-61 Whytecliffe Road South, Purley, CR8 1. SUMMARY 1.1 This report concerns

More information

Low Carbon Domestic Refurbishment

Low Carbon Domestic Refurbishment www.breeam.com Briefing Paper Low Carbon Domestic Refurbishment Kiruthiga Balson, Gavin Summerson and Steven Stenlund 2 BRE Global Ltd 2014 Permission is granted for this report to be distributed only

More information

Total doorset solutions, architectural ironmongery, access control and washroom fittings

Total doorset solutions, architectural ironmongery, access control and washroom fittings Total doorset solutions, architectural ironmongery, access control and washroom fittings Specialists in providing street furniture and cycle parking infrastructure solutions Dynamic glass solutions for

More information

an Inspector appointed by the Secretary of State for Communities and Local Government

an Inspector appointed by the Secretary of State for Communities and Local Government Appeal Decision Inquiry and Site Visit held on 10 July 2012 by Ahsan U Ghafoor BSc (Hons) MA MRTPI an Inspector appointed by the Secretary of State for Communities and Local Government Decision date: 23

More information

A Guide To The New Termite Standards (revised 09/02/2001)

A Guide To The New Termite Standards (revised 09/02/2001) Building Certifiers Building Designers rchitects Guide To The New Termite Standards (revised 09/02/2001) Introduction On 1 January 2001, the Building Code of ustralia (BC) was amended to incorporate new

More information

OWNER BUILDER AS AN WHAT ARE MY RESPONSIBILITIES UNDER THE DEVELOPMENT ACT 1993

OWNER BUILDER AS AN WHAT ARE MY RESPONSIBILITIES UNDER THE DEVELOPMENT ACT 1993 AS AN OWNER BUILDER building work? What records should I keep? Is insurance required? W I need approval for? What do I need approval for? How do I obtain building work? How do I obtain approval? What records

More information

Personal Tax Planning - What is a Resiliant or Resistance Measurement?

Personal Tax Planning - What is a Resiliant or Resistance Measurement? 1. Applicant Information Name of Applicant: Business Name (if applicable) Address: Postcode: Telephone Number Mobile: e-mail: 2. Property Flooded Address of property applying (if different from above),

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK to provide product conformity Stocking Lane High Wycombe Buckinghamshire HP14 4ND Contact: Mr Alan Gower Tel: +44 (0)1494 569700 Fax: +44 (0)1494 569701

More information

Materials and workmanship

Materials and workmanship The Materials and workmanship APPROVED DOCUMENT Regulation 7 2013 edition for use in England* 7 Main changes in the 2013 edition This approved document supports regulation 7: Materials and workmanship.

More information

Fire Resistant Systems

Fire Resistant Systems Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant

More information

TABLE OF CONTENTS 2 WHAT CAN A PLANNING OBLIGATION DO? 2 3 FORMALITIES 3 4 GOVERNMENT POLICY 3 5 PLANNING OBLIGATIONS AND CIL 5 6 COMMON PROVISIONS 5

TABLE OF CONTENTS 2 WHAT CAN A PLANNING OBLIGATION DO? 2 3 FORMALITIES 3 4 GOVERNMENT POLICY 3 5 PLANNING OBLIGATIONS AND CIL 5 6 COMMON PROVISIONS 5 TABLE OF CONTENTS 1 INTRODUCTION 2 2 WHAT CAN A PLANNING OBLIGATION DO? 2 3 FORMALITIES 3 4 GOVERNMENT POLICY 3 5 PLANNING OBLIGATIONS AND CIL 5 6 COMMON PROVISIONS 5 7 EXAMPLES OF SOME UNUSUAL PROVISIONS

More information

Lift and Escalator Installations

Lift and Escalator Installations Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-29 Lift and Escalator Installations Building Works Requirements The

More information

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS Table of Contents Purpose... 2 Commencement... 2 Application... 2 Referral Agency... 2 Compliance with the QDC... 2 Associated

More information

SERVICES 2015 ISO 18001

SERVICES 2015 ISO 18001 SERVICES 2015 A family business with a solid foundation of experience, we handle all aspects of site investigation.... Phase 1 Environmental Studies Phase 2 Intrusive Investigations Phase 3 Remediation

More information

MEMORANDUM. General: Foundation:

MEMORANDUM. General: Foundation: MEMORANDUM State of Alaska Department of Transportation and Public Facilities Central Region - Division of Construction and Operations Public Facilities Branch TO: Jennifer Murrel DATE: August 19, 2010

More information

Policy document on the provision of waste & recycling collection and storage facilities. Includes both domestic and commercial premises

Policy document on the provision of waste & recycling collection and storage facilities. Includes both domestic and commercial premises Policy document on the provision of waste & recycling collection and storage facilities Includes both domestic and commercial premises Introduction This document is intended to help relevant parties who

More information

SECTION 31 20 00 EARTH MOVING

SECTION 31 20 00 EARTH MOVING SECTION 31 20 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for excavating, filling, and grading for earthwork at Parking Structure, new exit stair and as required to

More information

DESIGN AND ACCESS STATEMENT PLANNING APPLICATION. 25 Gilston Road, SW10 9SJ June 2015

DESIGN AND ACCESS STATEMENT PLANNING APPLICATION. 25 Gilston Road, SW10 9SJ June 2015 DESIGN AND ACCESS STATEMENT PLANNING APPLICATION 25 Gilston Road, SW10 9SJ June 2015 CONTENTS 1.0 INTRODUCTION 2.0 SITE & CONTEXT 2.1 SITE CONTEXT 2.2 CONSERVATION AREA 3.0 BACKGROUND 3.1 RELEVANT PLANNING

More information

Demolition & Construction Management Plan

Demolition & Construction Management Plan Demolition & Construction Management Plan 72 76 Cadogan lane SW1 Demolition & Construction Management Plan Issue Date: March 2013 Contents: 1.0 Introduction 1.1 Objectives of the Plan 1.2 Project Overview

More information

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre Simplifying design and construction Alan Tovey, Director The Basement Information Centre Simplifying design and construction Grades of construction Construction options Design and waterproofing issues

More information

Tool 4.4: Individual house flood mitigation measures Costs and benefits

Tool 4.4: Individual house flood mitigation measures Costs and benefits Impacts of Climate Change on Urban Infrastructure & the Built Environment A Toolbox Tool 4.4: Individual house flood mitigation measures Costs and benefits Author Ian Page Affiliation BRANZ, Private Bag

More information

J. & W. LOWRY LIMITED. This case study has been prepared for J & W Lowry Limited By Thomas Elliott Foster

J. & W. LOWRY LIMITED. This case study has been prepared for J & W Lowry Limited By Thomas Elliott Foster J. & W. LOWRY LIMITED This case study has been prepared for J & W Lowry Limited By Thomas Elliott Foster 9/3/2013 Table of Contents 1.1.Brief... 2 2.1.Introduction... 3 Charles, J (2004).... 3 2.2.Foundation

More information

ASBESTOS MANAGEMENT SURVEY REPORT

ASBESTOS MANAGEMENT SURVEY REPORT ASBESTOS MANAGEMENT SURVEY REPORT for THE MORAY COUNCIL of B3239-1140002 Produced by ESG Asbestos Ltd, a wholly owned subsidiary of ESG Bretby Business Park, Ashby Road, Bretby, Burton upon Trent, Staffordshire

More information

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS NMP 1.4 EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS Index Purpose... 2 Application... 2 Referral Agency... 2 Associated Requirements... 2 Referenced Standards...2 Definitions...

More information

A Guide to the Design Build Process

A Guide to the Design Build Process A Guide to the Design Build Process Essential reading for anyone considering or undertaking building work We are an affiliation of Chartered Architects and Chartered Building Surveyors who together provide

More information

APPLICATION FOR BUILDING WARRANT

APPLICATION FOR BUILDING WARRANT THE BUILDING (SCOTLAND) ACT 2003 Application Under Section 9 for a Building Warrant to Construct, Demolish or Convert a Building, or to Provide Services, Fittings or Equipment in or in connection with

More information

Practice Note for Authorized Persons, Buildings Department Registered Structural Engineers and APP-13 Registered Geotechnical Engineers

Practice Note for Authorized Persons, Buildings Department Registered Structural Engineers and APP-13 Registered Geotechnical Engineers Practice Note for Authorized Persons, Buildings Department Registered Structural Engineers and APP-13 Registered Geotechnical Engineers Submission of Certificate of Completion of Building Works Application

More information

Rainwater Harvesting

Rainwater Harvesting Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth

More information

Repair and Renew Grant Scheme Leeds - Guidance to Applicants Purpose of the Fund

Repair and Renew Grant Scheme Leeds - Guidance to Applicants Purpose of the Fund Repair and Renew Grant Scheme Leeds - Guidance to Applicants Purpose of the Fund A Repair and Renew Grant (RRG) scheme has been set up to provide grants of up to 5,000 to homeowners and businesses that

More information

FLAT ROOF BOX SPAN CARPORTS

FLAT ROOF BOX SPAN CARPORTS AGS/NC/03 FLAT ROOF BOX SPAN CARPORTS Thank you for choosing this quality product. We strongly recommend that you read these instructions thoroughly. Please take your time and do not rush the erection

More information

Homeowner s Handbook

Homeowner s Handbook Homeowner s Handbook Congratulations on buying your new home This booklet will provide you with important information on the warranty cover for your new home which has been arranged by your developer.

More information

Relevant British, European and International standards

Relevant British, European and International standards Relevant British, European and International standards BS 1245:1975 Specification for metal door frames (steel) BS 3621:2007 + A1:2009 Thief resistant lock assemblies - Key egress BS 476-20:1987 Fire tests

More information

BUILDING CONTROL FEES

BUILDING CONTROL FEES BUILDING CONTROL FEES Domestic Fees (including VAT) April 2014 The s for Building Regulation have been established to cover the cost of the service. Pre application advice is available, the first hour

More information

Access to and use of buildings

Access to and use of buildings The Building Regulations 2010 Access to and use of buildings APPROVED DOCUMENT M Volume 1: Dwellings M4(1) Category 1: Visitable dwellings M4(2) Category 2: Accessible and adaptable dwellings M4(3) Category

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

Schedule A. Residential and Seasonal Dwellings. for estimating value of construction in the Township of North Kawartha

Schedule A. Residential and Seasonal Dwellings. for estimating value of construction in the Township of North Kawartha Schedule A Classification of buildings used for estimating value of construction in the Township of North Kawartha Estimated cost of Construction per square foot Residential and Seasonal Dwellings Single

More information

FLOODS FACT SHEET ADVICE FOR RESIDENTS Approvals for repairing, renovating or rebuilding flood-affected houses

FLOODS FACT SHEET ADVICE FOR RESIDENTS Approvals for repairing, renovating or rebuilding flood-affected houses 2 February 2011 Updated 16 March 2011 FLOODS FACT SHEET ADVICE FOR RESIDENTS Approvals for repairing, renovating or rebuilding flood-affected houses This fact sheet provides advice for residents about

More information

Proposed changes to the building control system. Consultation stage impact assessment

Proposed changes to the building control system. Consultation stage impact assessment Proposed changes to the building control system Consultation stage impact assessment Proposed changes to the building control system Consultation stage impact assessment January 2012 Department for Communities

More information

PROJECT BRIEF Version (insert number)

PROJECT BRIEF Version (insert number) PROJECT BRIEF Version (insert number) 1 Project Name ------------------------------------------------------------------- 1.1 The Project Project Address Nature of Work Location 1.2 DCC Client for Project

More information

building on success Trees and Basements Partial Review of the Core Strategy February 2014

building on success Trees and Basements Partial Review of the Core Strategy February 2014 building on success Trees and Basements Partial Review of the Core Strategy February 2014 Regulation 19, Town and Country Planning (Local Planning) (England) Regulations 2012. 2 Contents 1. Introduction...

More information

Building Warrant Issues

Building Warrant Issues Building Warrant Issues Frequently Asked Questions Introduction This section is intended to help anyone who is unfamiliar with the building standards system in Scotland. The information contained in it

More information

Guide to Conservatory Installation and Sewers

Guide to Conservatory Installation and Sewers ADVICE FOR TRADE AND CONSUMERS REFERENCE NUMBER 35.2 AUGUST 2011 Guide to Conservatory Installation and Sewers www.ggf.org.uk/publications GGF guide to the members of the Conservatory Association with

More information

A GUIDE TO WINDOW AND DOOR SELECTION

A GUIDE TO WINDOW AND DOOR SELECTION Australian window association guide series A GUIDE TO WINDOW AND DOOR SELECTION An industry guide to the selection and certification of windows and doors Background Foreword As part of its commitment to

More information

PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE

PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE PLANNING PERMISSION A GUIDE FOR EXTENDING A DETACHED OR SEMI-DETACHED HOUSE Introduction Foreword by Councilor Dave Smith - Chair of the Planning & Highways Committee. Planning Permissions B Owners of

More information

Put us to the test. Construction testing and building investigations services from BRE. www.bre.co.uk

Put us to the test. Construction testing and building investigations services from BRE. www.bre.co.uk Put us to the test Construction testing and building investigations services from BRE www.bre.co.uk Backed by an extraordinary range of facilities BRE prides itself on being able to answer virtually any

More information

VEHICLE CROSSOVER INFORMATION PACK

VEHICLE CROSSOVER INFORMATION PACK VEHICLE CROSSOVER INFORMATION PACK CONTENTS Introduction Section A Section B Section C Section D Section E Criteria for approving a vehicle crossover application (Diagrams to demonstrate measurement criteria)

More information

ONLINE VERSION ONLINE VERSION

ONLINE VERSION ONLINE VERSION The Building Regulations 2000 Sanitation, hot water safety and water efficiency G APPROVED DOCUMENT G1 G2 G3 G4 G5 G6 Cold water supply Water efficiency Hot water supply and systems Sanitary conveniences

More information

CONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality

CONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality CONTE NT DESIGN PROCESS First Issue 02 Revision A 03 Revision B 04 Co-ordination 05 Panel Thicknesses 06 Panel Surface Quality 07 CNC Timber Processing 08 Panel Standard Sizes 09 Glulam Standard Sizes

More information

Item: 16 Page: 5. 1. Purpose

Item: 16 Page: 5. 1. Purpose Item: 16 Page: 5 1. Purpose 1.1 Improving Choice in Verification of Building Standards. A Scottish Government consultation on the introduction of the National House Building Council (NHBC) for the verification

More information

The Guide To Waterproofing An Existing Basement

The Guide To Waterproofing An Existing Basement The Guide To Waterproofing An Existing Basement John Newton & Company is the leading independent supplier of basement waterproofing and damp proofing solutions in the UK. Newton System 500 is a maintainable

More information

Defects Insurance Scheme for ASUC

Defects Insurance Scheme for ASUC Defects Insurance Scheme for ASUC Presentation by Gary Devaney Managing Director M D Insurances Services Limited Who are M D Insurance Services Ltd? specialists in long term warranties housing commercial

More information

Glass and Building Regulations Impact Safety

Glass and Building Regulations Impact Safety Glass and Building Regulations Impact Safety England and Wales Approved Document N Scotland Part P Northern Ireland Part V Foreword For new buildings, and for buildings subject to major refurbishment,

More information

Instruction Manual 19/9/01. Flat Roof Carport

Instruction Manual 19/9/01. Flat Roof Carport Flat Roof Carport Thank you for choosing this quality carport. We strongly recommend that you read these instructions thoroughly. The carport you are building may vary from a carport previously bought

More information

How To Retaining Wall Guide

How To Retaining Wall Guide How To Retaining Wall Guide Before you start: Consents and Engineering Building Consent Retaining walls over 1.5m high will require a building consent from the Local Body Council. Walls that carry extra

More information

FABRIC ENERGY EFFICIENCY FOR PART L 2013

FABRIC ENERGY EFFICIENCY FOR PART L 2013 Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub

More information

CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is

CITY OF ST. CA THARINE S. cn- Olc.4 BY-LAW NO. WHEREAS the Council of the Corporation of the City of St. Catharines, is ~: ~,,' " CITY OF ST. CA THARINE S BY-LAW NO. cn- Olc.4 A By-law to regulate sanitary and storm drainage. WHEREAS the Council of the Corporation of the City of St. Catharines, is authorized by the provisions

More information

Residential Foundations and Basements

Residential Foundations and Basements Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article

More information

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production

More information

WASTE STORAGE AND COLLECTION

WASTE STORAGE AND COLLECTION BASSETLAW DISTRICT COUNCIL ENVIRONMENT SERVICES GUIDANCE FOR NEW DEVELOPMENTS WASTE STORAGE AND COLLECTION IN BASSETLAW 26 October 2011 PURPOSE OF THIS DOCUMENT This guidance document is intended to aid

More information

HOUSE BUILDING DIGEST

HOUSE BUILDING DIGEST HOUSE BUILDING DIGEST (Construction Specifications-Foundations) Creating Enabling Environment for Affordable Housing for All This is an attempt by BMTPC to provide useful but often ignored information

More information

Department for Communities and Local Government

Department for Communities and Local Government Department for Communities and Local Government Permitted development for householders Technical Guidance April 2014 Department for Communities and Local Government Please note: This technical guidance

More information

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R Legislation passed by the 82 nd legislature has modified the Texas Engineering Practice Act and the Texas Architect Practice Act. In order to give the public a clearer understanding of these changes, the

More information

MagTek A. Aluminium Manual Attack Resistant Doors

MagTek A. Aluminium Manual Attack Resistant Doors MagTek A Aluminium Manual Attack Resistant Doors MANUAL ATTACK-RESISTANCE Gunnebo s manual attack resistant doors have been designed to satisfy the ever increasing need to protect people, property and

More information