Richard S. Olsen, PhD, PE Acting Principle Geotechnical Engineer

Size: px
Start display at page:

Download "Richard S. Olsen, PhD, PE Acting Principle Geotechnical Engineer"

Transcription

1 The Cone Penetrometer Test (CPT) for Earth Dams 2016 Feb 18 NDSP Technical Seminar No. 23 Internal Evaluation Techniques for Earthen Dams FEMA and National Dam Safety Review Board Richard S. Olsen, PhD, PE Acting Principle Geotechnical Engineer Geotechnical & Materials CoP Lead Headquarters Engineering & Construction Division US Army Corps of Engineers (USACE) Washington DC

2 CPT measurements Sleeve Friction Resistance, f s Cone Resistance, q c Measured pore pressure

3 20 TON TRUCK CPT Sounding Data Plot Cone Resistance, (tsf) q c Sleeve Friction Resistance (tsf) f s Speed of Push 2cm/sec (~4ft/minute) Sleeve Friction Resistance, f S Cone Resistance, q C 1-meter connecting rod Reporting the Cone Penetrometer Test (CPT) f s Friction Ratio = 100 q c The sleeve percentage of the cone resistance!

4 Meaning of the CPT Measurements Sleeve Friction Resistance is proportional to large strain effects and lateral stress conditions Cone Resistance is proportional to the initial structure Lateral Stress Conditions Soil Remolding and Grain Rearrangement

5 The CPT is the most cost effective tool for site investigation of soil sites! The CPT is probably the best tool for estimating geotechnical properties!

6 Borings$ = CPT$ x 7 (ranges from 5 to 10) Boring and lab testing Drilling borings 60 to 155 $/foot Lab testing 5 to 120 $/foot Evaluation 1 to 10 $/foot Cone Penetrometer Test (CPT) CPT testing 10 to 25 $/foot Evaluation 0 to 15 $/foot 300 to 600 feet/day 40 to 90 feet/day

7 What if and why is critical for the CPT DON T JUST USE SIMPLE DATA PROCESSING SOFTWARE think Remember geotechnical engineering is not about crunching numbers Most geotechnical failures and issues are due to problems that COULD have been found rather than computed

8 What is the propose of CPT? 1) to find isolated weak zones (the first CPT sounding defines the site conditions - all other soundings either confirm or show geological change) 2) to provide estimates of soil properties, 3) to generate cross sections, and 3) for comparison to nearby borings (verification or to establish correlations)

9 The Initial sand structure is dependent on the deposition environment The CPT is the best tool for indexing the relative structure of the sand structure Flowing river Not flowing

10 Sand-silt-clay mixtures can be potentially unstable This type of metastable structure can be detected with the CPT, specifically using the sleeve friction resistance The sleeve resistance can detect this condition

11

12 Weak and soft soil The Cone stress bulb is maybe only one probe diameters below the tip Cone can detect and measure thin layers but the sleeve 5 inches long Stiff and dense soil approx. 20 cm (7.8 inch) approx. 8 cm (3.4 inch) The Cone stress bulb is many Probe diameters below the tip Weak Soil The sleeve at 5 inches long can detect 5 inch soil layers however the cone can influencing a depth of 10 or more inches Stiff Soil Zone of plastic flow

13 We are using the Academic Quality Index (AQI) at all levels (i.e. great data has an A grade (or AQI of 95%) and a ok data is a C or 75%) AQI is better than saying pick a quality index from 0 to 10 AQI is also repeatable AQI can also be a sum of many sub-aqi items, For example; AQI for CPT zero load issues, AQI for CPT stratigraphy issues, AQI for cone type

14 CPT Equipment

15 Compression designed cone Sleeve load cell (compression loading) (not loaded in tension) Sleeve loading Cone load cell (loaded in compression and tension) Subtraction cone The inside of a typical CPT probes Tension cone

16 Between cone and sleeve Seal Face Standard Tip Porous Filter

17 Silt can get into these joints and cause zero load offset problems Measure the pre- and post- zero loads to identify possible zero load offset problems

18

19 ERDC SCAPS CPT truck system

20 Terracon s Swamp CPT WES first CPT

21 GeoStaff CPT boat for near shore soft soil testing (1995)

22

23

24 Suitcase CPT system 1994 SCAPS system GeoStaff boat

25 USACE Vicksburg Panama Canal ERTEC in long Beach WES SCAPS at Jacksonville Army base WES SCAPS SWAMP rig - AB

26 Greg CPT on Sacramento levees

27 FUGRO all terrain CPT rig UGRO special purpose rig

28 Four leg jack up (spud barge) for performing CPT soundings

29 Clark s Field vane shear and mini penetrometer rig (Seattle, Washington 1973)

30 CPT Cone Resistance Stress Normalization (determining equivalent value at a vertical effective stress of 1 atm)

31 CPT Boring Normalization Stress Normalization q q c q 1= σ ' c1 = c v q c σ ( σ ' ) total c Stress exponent ( variable, 0.1 to 1 ) v Normalized CPT Parameters CPT estimation of geotechnical properties f s q c f sle q cle Stress Normalization Normalized geotechnical property Use Stress normalization techniques to include stress effects Geotechnical property CPT Measurements

32 1000 Cone resistance stress exponent (for stress normalization) c=0.55 c=0.75 Fines < 5% SCN=2 Medium dense Very loose Loose SCN=1 c= 1 Soil Classification Number (SCN) (Olsen 1995 version) SCN=0 Sand clayey silt fine sand silty sand Silt Olsen & Mitchell (1995) Olsen (1988) sandy silt silty clay Dense Fines = 10 to 15% 80 Fines = SCN= -1 SCN= Friction Ratio (%) silty clay c=0.15 c=0.35 Normally to 100% Peats Sand & Gravel Normalized cone resistance (atm units) Sand mixtures Fines = 40 to 60% mixtures consolidated Clays Increasing over consolidation Increasing over consolidation Organic clay and unstable clayey silts The c stress exponent q = c1 q c σ ( σ ' ) v total c

33 Stress effects are VERY important for shallow (low stress) and deep situations Underwater shallow depths (< 2 m), F v = 0.02 to 0.1 atm Foundations for for large dams, F v = 10 to 20 atm atm. tsf. kgf/cm 2 (Vertical Effective Stress) St-hi-lw.wpg

34 CPT soil classification The changing CPT based Soil Classification chart over the last 28 years plus stress normalization Richard Olsen, PhD, PE USACE-ERDC Geo-Omaha Conference - Feb 15, 2008

35 Richard Olsen, PhD, PE USACE-ERDC Geo-Omaha Conference - Feb 15, 2008

36 Olsen & Mitchell (1995) Olsen (1988) SCN=2 Very loose Loose SCN=1 Soil 10 Classification Number (SCN) (Olsen 1995 version) SCN=0 Medium dense Sand fine sand silty sand silt clayey Fines < 5% Silt sandy silt silty clay Fines = Dense SCN= -1 SCN= Friction Ratio (%) silty clay Peats scn9703n.grf OLSEN 03/03/98 The CPT soil characterization chart for predicting soil type and estimating fines content (Olsen & Mitchell, 1995) Normalized cone resistance (atm units) Sand & Gravel Fines = 10 to 15% Sand mixtures mixtures Normally consolidated Fines = 40 to 60% 80 to 100% Clays Increasing over consolidation Increasing over consolidation Organic clay and unstable clayey silts The CPT soil characterization chart provides the means for accurate estimation of soil properties and behavior trends Silt NC Clay

37 History of Charts 38

38 Advanced Geotechnical Site Characterization CE Fall Dr Richard Olsen Class Notes 15 39

39 Advanced Geotechnical Site Characterization CE Fall Dr Richard Olsen Class Notes 15 40

40 Olsen 2007 and 2012 versions Advanced Geotechnical Site Characterization CE Fall Dr Richard Olsen Class Notes 15 41

41 2016 trending of OCR cle Olsen 2016

42 CPT prediction of earthquake liquefaction Resistance I ve spent 25+ years developing contours of predicted properties on the soil characterization chart AND Explaining the shape and location of these contours I will fully explain many of the prediction in 10 minutes. Normalized Cone Resistance (atm units) Olsen et al 1984, 1986, 1988, 1992, 1995,1998, 1999 Loose Sands Medium Dense 0.1 Dense Sand Mixtures Silt Mixtures 0.2 over consolidation Clays 0.3 CPT estimated CRR Friction Ratio (%)

43 Poor prediction of SPT The q c /N ratio Richard Olsen, PhD, PE USACE-ERDC Geo-Omaha Conference - Feb 15, 2008 Seed

44 Predicting SPT Prediction of normalized SPT blow count (N 1 ) Richard Olsen, PhD, PE USACE-ERDC Geo-Omaha Conference - Feb 15, 2008

45 An example of CPT estimated soil property versus measured values The CPT soil characterization technique is the best CPT-based technique for estimating soil properties because it uses both CPT measurements and uses the Stress Focus theory for stress normalization (Olsen, 1994)

46 Prediction of total unit weight

47 shear wave velocity Measuring Shear Wave Velocity using the Electric CPT High Capacity CPT truck Reverse hit for shear wave generation Vandehey Soil Exploration Wood plank The wood plank (or steel/wood assembly) can also be positioned under the truck leveling jacking pads Reverse wave Reverse wave Primary wave Primary hit for shear wave generation V s1 Use of primary and reverse hits are important to differentiate the shear wave first arrival from noise and compression waves, especially for tests near the ground surface. Miniature precision geophone (positioned for horizontal shear waves) Wave front Primary wave Enlarged section Sleeve Friction Resistance, f s Cone Resistance, q c Travel time to geophone The slope is the shear wave velocity, V s (feet/second) or (meters/second)

48 Prediction of shear wave velocity Old predicting V s1 CPT-based estimation of the normalized shear wave velocity V s1 = (Olsen, 1988) V s v 0.25 V s1 proportional to f s1 But f s1 proporttional to S r Interestly, V s1 and S r are both related to steady state behavior

49 Prediction of shear wave velocity Predicting V s1 CPT-based estimation of the normalized shear wave velocity V s1 = (Olsen, 1994, 1995) V s v 0.25

50 example An example comparison of measured shear wave velocity and CPT estimated shear wave velocity

51 example Another comparison example (uniform bomb blast site)

52 Clay strength We normally look a undrained (relatively quick) failures. So, clay undrained strength is represented as; S u the US standard engineering units are pounds per square foot (psf) Normalized undrained clay strength S u1 = S u v = c/p Vertical effective stress in tsf units = 0.31 for UU test based normal clays with no organics and not illite clay (For slope stability analysis the UU is the standard test) = 0.25 for Simple shear and other specialized laboratory tests = 0.18 to 0.3 organic based clays

53 Prediction of Predicting Strength soil strength Example S u1 or c/p of version

54 Predicting Liquefaction Olsen & Koester 1995

55 Olsen 2015

56 2015 prediction of CRR e Olsen 2015

57 Olsen 2015 Going from clean sand to Normally consolidated clay For CRR 1 =0.2 i.e. CRR e = 0.2

58 Predicting S ues1 Prediction of after earthquake strength Medium dense sands Loose to medium sands Very loose sands Strength of normally consolidated clay (c/p =0.31) Normally Consolidated Clay Normalized Cone Resistance (atm units) Olsen 1987, 1994, 1998 Unpublished - WES data and correlations Friction Ratio (%) qcfr-ws-cleanedup Olsen WES

59 Predicting boil potential Prediction of Sand and Silt Boil Expression Loose sand silt Sand only boils silt Loose sand Silt and sand boils Silt erosion Silt needs to be eroded to be brought to the ground surface Normalized Cone Resistance (atm units) Richard Olsen, PhD, PE USACE-ERDC Midwest DOT Geotechnical Conference Sept 23, 2008 Loose High Pure Silts are very erosion Sands Medium Dense Moderate Dense Sand Mixtures High Moderate Silt Mixtures None Low Clays Friction Ratio (%) over consolidation None None None None

60 Predicting C c Prediction of consolidation parameter This is great for differential settlement calculations Project experience indicates that predicted total settlement can be off by a factor as much as 3 but the differential settlement (ratio) is generally within 25% of laboratory based data. C c 1 + e 0

61 Predicting volume change Prediction of VOLUME CHANGE due to shaking Normalized Cone Resistance (atm units) Very High Loose High High Sands Moderate Dense Medium Dense Sand Mixtures Moderate Low None Low Silt Mixtures None None over consolidation Clays Friction Ratio (%)

62 Predicting Modulus reduction Prediction of Modulus reduction due to liquefaction shear CRR E liquefaction E 50 (Youngs modulus) E 50 dynamic Static (loose sand) 5% strain E Liq 100 (%) strain Normalized Cone Resistance (atm units) times reduction for loose sand Loose Watch out for sensitive silts and soil mixtures 20 time reduction for dense sand - however dense sand will dilate with shear Sands Medium Dense 0.1 2% Dense Sand Mixtures Silt Mixtures 0.2 5% 3% over consolidation Clays % CPT estimated CRR 1 25% Clay Friction Ratio (%)

63 Permeability (cm/sec) SM-ML % passing #200 or D 10 (mm) Final design S u Elevation (feet) Depth below crest (feet) SM SP SM SP Laboratory permeability Laboratory measured D p + u + Trend based on measured data Laboratory based trend Estimated trend from D 10 SC FFSWdepth. Required plots that should be added to computer seepage modeling output 64

64 CPT predicted cross sections CPT Cross sections requires good CPT investigation planning CPT value requires good cross sections

65 3D volume modeling requires too many CPT soundings to properly visualize the soil. SCAPS research to test for petroleum and visualized the results However, 2D cross sections are easily to economically justify 3D volume modeling of clayey soils 1990 high tech Easy in 2016 But not used

66

67 The CPT cross section concept (in this case predicted strength) CPT soundings Interpolate the strengths between the two adjacent CPTs (using one of 4 techniques) Commercial contouring software does not create proper alluvial layers watch out Water table Elevation CPT predicted strength of 750 psf for CPT 308C 450 psf for CPT 307C

68 Let us now compare the normal cross sections to CPT predicted cross sections

69 CPT predicted Soil type (Olsen method) For complete site characterization, you must have cross sections of CPT predicted; Soil type, Strength, & Normalized strength

70 CPT predicted Normalized strength (Olsen method) For complete site characterization, you must have cross sections of CPT predicted; Soil type, Strength, & Normalized strength Richard Olsen, PhD, PE USACE-ERDC Geo-Omaha Conference - Feb 15, 2008 Richard Olsen, PhD, PE USACE-ERDC-GSL-GEGB Omaha District Citrus levee meeting 10Jan2008 at New Orleans

71 CPT predicted strength (using Nk = 11) Note: a higher Nk will cause a lower predicted strength For complete site characterization, you must have cross sections of CPT predicted; Soil type, Strength, & Normalized strength Richard Olsen, PhD, PE USACE-ERDC-GSL-GEGB Omaha District Citrus levee meeting 10Jan2008 at New Orleans

72 CPT predicted strength (using a Olsen method) For complete site characterization, you must have cross sections of CPT predicted; Soil type, Strength, & Normalized strength Richard Olsen, PhD, PE USACE-ERDC-GSL-GEGB Omaha District Citrus levee meeting 10Jan2008 at New Orleans

73 CPT predicted soil type - for comparison Zoomed in to compare boring based CAD cross sections to CPT cross section 20 feet Soil type Strength cross section Normalized Strength cross section 20 feet

74 LPV CPT predicted soil type Using the chimney effect with cross section - final QA on CPT data

75 CPT predicted soil type Comparing lateral stratigraphy boring based CAD approach to CPT cross sections Many CPTs (for 2000 ft) because of economics Only two borings for 2000 feet

76 Shallow near offshore project client wanted gray scale only (prediction of undrained strength) 1994

77 Richard Olsen, PhD, PE USACE-ERDC Geo-Omaha Conference - Feb 15, 2008

78 Gatun Dam (hydraulic fill dam) Cross section of soil type (red is sand and blue is clay) (this cross section was developed using custom soil tracing CAD/gridding software) Note the CONTINOUS sloping sand layer! Upstream downstream

79 A C B Complex stratigraphy can become extremely important

80 FIRST STEP - CPT predicted soil type The process of generating CPT based cross sections is not quick nor magic This is the initial output for the specialized gridding software QA, section inspection, removal of chimney effects, and DB verification are still required

81 MIDDLE STEP - CPT predicted soil type

82 FINAL CPT - predicted soil type

83 LPV CPT predicted soil type can it effect landform? Deep seated sandy deposit (i.e much lower settlement potential) Richard Olsen, PhD, PE USACE-ERDC-GSL-GEGB Omaha District Citrus levee meeting 10Jan2008 at New Orleans

84 Non linear layering due to differential settlement A A

85 This surface (A-A) was level before new sediment was added A Ground surface (but it must be level) Lets move back in time when layer interface A was being deposited A

86 This surface (A-A) level can be forced to be level A Moderate consolidation potential Level ground at deposition Moderate consolidation potential Low consolidation potential High consolidation potential A Moderate consolidation potential Shallow clay Full depth of sands and clays Deep clay Full depth of sand with clays Deep clay Shallow mixture

87 The recent sediment caused the (A-A) line that we now see A A

88 LAST TOPIC CPT measurements (with AQI) CQI) Boring Laboratory testing (with AQI) CQI) CPT (Good stratigraphic CQI) Good stratigraphy, e.g. AQI=95% (Poor stratigraphic CQI) Poor stratigraphy, e.g. AQI=60% Overall AQI = low or low average of all individual AQIs Overall CQI = CPT CQI & Laboratory/sample CQI & Stratigraphy CQI

89 Remove soil boring CPT too close CPT correct distance Maybe too far away for correlation purposes How to solve this issue? Lateral stress decreases First perform CPT soundings then borings Richard Olsen, PhD, PE USACE-ERDC Geo-Omaha Conference - Feb 15, 2008 Lower lateral stress due to nearby borehole

90 Predicted strength Cross section of strength Depth plots of strength Elevation

91 LPV 146 MER study area - CPT predicted strength vs measured dots FINAL topic

92 Excellent correlation Excellent correlation Excellent correlation Width of a typical house

93 1000 Olsen & Mitchell (1995) Olsen (1988) 100 Very loose Loose SCN=1 Soil 10 Classification Number (SCN) (Olsen 1995 version) SCN=0 Sand & Gravel Fines < 5% Dense SCN=2 Medium dense Sand fine sand silty sand clayey silt Sand sandy silt silty clay Fines = 10 to 15% Fines = 40 to 60% Fines = 80 to 100% Clays SCN= -1 SCN= -2 Increasing over consolidation Organic clay and unstable clayey silts Friction Ratio (%) silty clay Peats scn9703n.grf OLSEN 03/03/98 Normalized cone resistance (atm units) mixtures Silt mixtures Normally consolidated Increasing over consolidation Thank You Rick Olsen

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District Recommended publications ASTM D 5778-07 Standard Test Method for Electronic Friction Cone and Piezocone

More information

NOTES on the CONE PENETROMETER TEST

NOTES on the CONE PENETROMETER TEST GE 441 Advanced Engineering Geology & Geotechnics Spring 2004 Introduction NOTES on the CONE PENETROMETER TEST The standardized cone-penetrometer test (CPT) involves pushing a 1.41-inch diameter 55 o to

More information

Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G.

Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS. J. David Rogers, Ph.D., P.E., R.G. Fundamentals of CONE PENETROMETER TEST (CPT) SOUNDINGS J. David Rogers, Ph.D., P.E., R.G. Cone Penetration Test CPT soundings can be very effective in site characterization, especially sites with discrete

More information

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions This is an attempt to create a stand alone self learning module on site investigation. Fasten your seat belts. Sit back, relax and enjoy. 1 2 Site Investigation Some unsung heroes of Civil Engineering

More information

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc. Design Manual Chapter 6 - Geotechnical 6B - Subsurface Exploration Program 6B-2 Testing A. General Information Several testing methods can be used to measure soil engineering properties. The advantages,

More information

CIVL451. Soil Exploration and Characterization

CIVL451. Soil Exploration and Characterization CIVL451 Soil Exploration and Characterization 1 Definition The process of determining the layers of natural soil deposits that will underlie a proposed structure and their physical properties is generally

More information

Soil behaviour type from the CPT: an update

Soil behaviour type from the CPT: an update Soil behaviour type from the CPT: an update P.K. Robertson Gregg Drilling & Testing Inc., Signal Hill, California, USA ABSTRACT: An initial application of CPT results is to evaluate soil type and soil

More information

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:! In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible

More information

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance

More information

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 13 (Refer Slide Time: 00:18) So last class, it was

More information

14.330 SOIL MECHANICS Assignment #4: Soil Permeability.

14.330 SOIL MECHANICS Assignment #4: Soil Permeability. Geotechnical Engineering Research Laboratory One University Avenue Lowell, Massachusetts 01854 Edward L. Hajduk, D.Eng, PE Lecturer PA105D Tel: (978) 94 2621 Fax: (978) 94 052 e mail: Edward_Hajduk@uml.edu

More information

Washington 98102-3699, mike.bailey@hartcrowser.com

Washington 98102-3699, mike.bailey@hartcrowser.com LESSONS LEARNED FROM A STONE COLUMN TEST PROGRAM IN GLACIAL DEPOSITS Barry S. Chen 1, P.E., Member, Geo-Institute and Michael J. Bailey 2, P.E., Member, Geo-Institute ABSTRACT A stone column test program

More information

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer HS-4210_MAN_09.08 product manual HS-4210 Digital Static Cone Penetrometer Introduction This Manual covers the measurement of bearing capacity using the Humboldt Digital Static Cone Penetrometer (DSCP).

More information

ENCE 4610 Foundation Analysis and Design

ENCE 4610 Foundation Analysis and Design This image cannot currently be displayed. ENCE 4610 Foundation Analysis and Design Shallow Foundations Total and Differential Settlement Schmertmann s Method This image cannot currently be displayed. Strength

More information

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Brussels, 18-20 February 2008 Dissemination of information workshop 1 Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing Dr.-Ing. Bernd Schuppener, Federal Waterways Engineering

More information

KWANG SING ENGINEERING PTE LTD

KWANG SING ENGINEERING PTE LTD KWANG SING ENGINEERING PTE LTD 1. INTRODUCTION This report represents the soil investigation works at Aljunied Road / Geylang East Central. The objective of the soil investigation is to obtain soil parameters

More information

Caltrans Geotechnical Manual

Caltrans Geotechnical Manual Cone Penetration Test The cone penetration test (CPT) is an in-situ sounding that pushes an electronic penetrometer into soil and records multiple measurements continuously with depth. Compared with rotary

More information

EVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND

EVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND EVALUATING THE IMPROVEMENT FROM IMPACT ROLLING ON SAND D.L. Avalle, Broons Hire (SA) Pty Ltd, Australia J.P. Carter, The University of Sydney, Australia Abstract Impact rolling, utilising a non-circular

More information

Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT

Strength Determination of Tooth-Paste Like Sand and Gravel Washing Fines Using DMT Strength Determination of "Tooth-Paste" Like Sand and Gravel Washing Fines Using DMT David L. Knott, P.E. and James M. Sheahan, P.E. HDR Engineering, Inc. 3 Gateway Center Pittsburgh, PA 15222-1074 Phone:

More information

ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects

ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects CPT Cone Penetration Testing ODOT/OSU collaboration on the development of CPT Capabilities for use in Ohio Transportation Projects Presented by: Jason Ross, Staff Engineer, BBC&M Engineering, Inc. Kirk

More information

GEOTECHNICAL ENGINEERING FORMULAS. A handy reference for use in geotechnical analysis and design

GEOTECHNICAL ENGINEERING FORMULAS. A handy reference for use in geotechnical analysis and design GEOTECHNICAL ENGINEERING FORMULAS A handy reference for use in geotechnical analysis and design TABLE OF CONTENTS Page 1. SOIL CLASSIFICATION...3 1.1 USCS: Unified Soil Classification System...3 1.1.1

More information

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell Cone Penetration Testing in Geotechnical Practice Tom Lunne Peter K. Robertson John J.M. Powell BLACKIE ACADEMIC & PROFESSIONAL An Imprint of Chapman & Hall London Weinheim New York Tokyo Melbourne Madras

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 Introduction The design and construction of foundations require a good knowledge of the mechanical behaviour of soils and of their spatial variability. Such information can be

More information

Use and Application of Piezocone Penetration Testing in Presumpscot Formation

Use and Application of Piezocone Penetration Testing in Presumpscot Formation Use and Application of Piezocone Penetration Testing in Presumpscot Formation Craig W. Coolidge, P.E. Summit Geoengineering Services, Rockland, Maine ABSTRACT: This paper examines the advantages and limitations

More information

GUIDE TO CONE PENETRATION TESTING

GUIDE TO CONE PENETRATION TESTING GUIDE TO CONE PENETRATION TESTING www.greggdrilling.com Engineering Units Multiples Micro (μ) = 10-6 Milli (m) = 10-3 Kilo (k) = 10 +3 Mega (M) = 10 +6 Imperial Units SI Units Length feet (ft) meter (m)

More information

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST 1 Permeability is a measure of the ease in which water can flow through a soil volume. It is one of the most important geotechnical parameters. However,

More information

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS E. J. Newman 1, T. D. Stark 2, and S. M. Olson 3 ABSTRACT Refined relationships between

More information

How To Design A Foundation

How To Design A Foundation The Islamic university - Gaza Faculty of Engineering Civil Engineering Department CHAPTER (2) SITE INVESTIGATION Instructor : Dr. Jehad Hamad Definition The process of determining the layers of natural

More information

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Proceedings of Indian Geotechnical Conference IGC-2014 December 18-20, 2014, Kakinada, India ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Kant, L., M. Tech Student, Department of Earthquake

More information

PILE FOUNDATIONS FM 5-134

PILE FOUNDATIONS FM 5-134 C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics

More information

Anirudhan I.V. Geotechnical Solutions, Chennai

Anirudhan I.V. Geotechnical Solutions, Chennai Anirudhan I.V. Geotechnical Solutions, Chennai Often inadequate In some cases, excess In some cases, disoriented Bad investigation Once in a while good ones Depends on one type of investigation, often

More information

Chapter 7 Analysis of Soil Borings for Liquefaction Resistance

Chapter 7 Analysis of Soil Borings for Liquefaction Resistance Chapter 7 Analysis of Soil Borings for Liquefaction Resistance 7.1. Introduction. This chapter addresses the analysis of subsurface soil data to determine the factor of safety against liquefaction and

More information

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº 84-14 of 204 ; TEL : 6916043 E-mail: igr@ingeoriesgos.com

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº 84-14 of 204 ; TEL : 6916043 E-mail: igr@ingeoriesgos.com The plot below presents the cross correlation coeficient between the raw qc and fs values (as measured on the field). X axes presents the lag distance (one lag is the distance between two sucessive CPT

More information

Figure 2.31. CPT Equipment

Figure 2.31. CPT Equipment Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3

More information

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska

How To Prepare A Geotechnical Study For A Trunk Sewer Project In Lincoln, Nebraska APPENDIX B Geotechnical Engineering Report GEOTECHNICAL ENGINEERING REPORT Preliminary Geotechnical Study Upper Southeast Salt Creek Sanitary Trunk Sewer Lincoln Wastewater System Lincoln, Nebraska PREPARED

More information

An Automatic Kunzelstab Penetration Test

An Automatic Kunzelstab Penetration Test An Automatic Kunzelstab Penetration Test Yongyuth Sirisriphet 1, Kitidech Santichaianant 2 1 Graduated student: Faculty of Industrial Education in and Technology. King Mongkut's University of Technology

More information

GUIDE TO CONE PENETRATION TESTING

GUIDE TO CONE PENETRATION TESTING GUIDE TO CONE PENETRATION TESTING www.greggdrilling.com Engineering Units Multiples Micro (μ) = 10-6 Milli (m) = 10-3 Kilo (k) = 10 +3 Mega (M) = 10 +6 Imperial Units SI Units Length feet (ft) meter (m)

More information

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1 INTRODUCTION TO SOIL MODULI By Jean-Louis BRIAUD 1 The modulus of a soil is one of the most difficult soil parameters to estimate because it depends on so many factors. Therefore when one says for example:

More information

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey

Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey Using Combination of SPT, DMT and CPT to Estimate Geotechnical Model for a Special Project in Turkey Figen Orhun Onal GE, M.Sc., Site Works Manager, Zemin Etud ve Tasarım A.Ş., Istanbul, figen.orhun@zetas.com.tr

More information

Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT)

Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT) RESEARCH ARTICLE OPEN ACCESS Evaluation of Post-liquefaction Reconsolidation Settlement based on Standard Penetration Tests (SPT) AlketaNdoj*,VeronikaHajdari* *Polytechnic University of Tirana, Department

More information

Soil Classification Through Penetration Tests

Soil Classification Through Penetration Tests Pak. J. Engg. & Appl. Sci. Vol. 9, Jul., 2011 (p. 76-86) Soil Classification Through Penetration Tests A. H. Khan, A. Akbar, K. Farooq, N. M. Khan, M. Aziz and H. Mujtaba Department of Civil Engineering,

More information

Trench Rescue by Buddy Martinette

Trench Rescue by Buddy Martinette Trench Rescue by Buddy Martinette SOIL TYPE AND TESTING It is imperative that rescue personnel understand soil types and testing procedures if the want to be competent at trench rescue operations. Determining

More information

NUMERICAL ANALYSIS OF SEEPAGE THROUGH EMBANKMENT DAMS (CASE STUDY: KOCHARY DAM, GOLPAYEGAN)

NUMERICAL ANALYSIS OF SEEPAGE THROUGH EMBANKMENT DAMS (CASE STUDY: KOCHARY DAM, GOLPAYEGAN) NUMERICAL ANALYSIS OF SEEPAGE THROUGH EMBANKMENT DAMS (CASE STUDY: KOCHARY DAM, GOLPAYEGAN) *Reza Naghmehkhan Dahande 1 and Ahmad Taheri 2 1 Department of Civil Engineering-Water Management, Islamic Azad

More information

LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES

LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES Test Procedure for LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES TxDOT Designation: Tex-142-E Effective Date: August 1999 1. SCOPE 1.1 This method is a system for classifying disturbed and

More information

Drained and Undrained Conditions. Undrained and Drained Shear Strength

Drained and Undrained Conditions. Undrained and Drained Shear Strength Drained and Undrained Conditions Undrained and Drained Shear Strength Lecture No. October, 00 Drained condition occurs when there is no change in pore water pressure due to external loading. In a drained

More information

Comprehensive Design Example 2: Foundations for Bulk Storage Facility

Comprehensive Design Example 2: Foundations for Bulk Storage Facility Comprehensive Design Example 2: Foundations for Bulk Storage Facility Problem The project consists of building several dry product storage silos near an existing rail siding in an open field presently

More information

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone

More information

APPENDIX A PRESSUREMETER TEST INTERPRETATION

APPENDIX A PRESSUREMETER TEST INTERPRETATION APPENDIX A PRESSUREMETER TEST INTERPRETATION PRESSUREMETER TEST INTERPRETATION Description of test The pressuremeter test, discussed in great detail by Martin (1977), Baguelin et al. (1978), Barksdale

More information

2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA

2009 Japan-Russia Energy and Environment Dialogue in Niigata S2-6 TANAKA ERINA Importance of the Site Investigation for Development of Methane Hydrate Hokkaido University Hiroyuki Tanaka Civil Engineer My Background Site Investigation Soil Parameters for Design Very Soft Clay and

More information

Numerical Simulation of CPT Tip Resistance in Layered Soil

Numerical Simulation of CPT Tip Resistance in Layered Soil Numerical Simulation of CPT Tip Resistance in Layered Soil M.M. Ahmadi, Assistant Professor, mmahmadi@sharif.edu Dept. of Civil Engineering, Sharif University of Technology, Tehran, Iran Abstract The paper

More information

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE 9.1 INTRODUCTION An important reason that composite piles have not gained wide acceptance in the civil engineering practice is the lack of a long

More information

DIRECTIONAL DRILLING

DIRECTIONAL DRILLING DIRECTIONAL DRILLING 1. General. Installation of pipelines through the levee embankment using directional drilling technology is prohibited. Installation of pipelines through a flood control project foundation

More information

The Challenge of Sustainability in the Geo-Environment Proceedings of the Geo-Congress 2008 ASCE New Orleans LA

The Challenge of Sustainability in the Geo-Environment Proceedings of the Geo-Congress 2008 ASCE New Orleans LA The Challenge of Sustainability in the Geo-Environment Proceedings of the Geo-Congress 2008 ASCE New Orleans LA Strength and Permeability of a Deep Soil Bentonite Slurry Wall Christopher R. Ryan P.E. M

More information

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration

More information

ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS

ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS Studia Geotechnica et Mechanica, Vol. XXXV, No. 4, 213 DOI: 1.2478/sgem-213-33 ON THE INTERPRETATION OF SEISMIC CONE PENETRATION TEST (SCPT) RESULTS IRENA BAGIŃSKA Wrocław University of Technology, Faculty

More information

Geotechnical Testing Methods II

Geotechnical Testing Methods II Geotechnical Testing Methods II Ajanta Sachan Assistant Professor Civil Engineering IIT Gandhinagar FIELD TESTING 2 1 Field Test (In-situ Test) When it is difficult to obtain undisturbed samples. In case

More information

CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the

More information

Cone Penetration Test (CPT)

Cone Penetration Test (CPT) Cone Penetration Test (CPT) The cone penetration test, or CPT in short, is a soil testing method which will provide a great deal of high quality information. In the Cone Penetration Test (CPT), a cone

More information

STP883-EB/Nov. 1985. Subject Index

STP883-EB/Nov. 1985. Subject Index STP883-EB/Nov. 1985 Subject Index A Aas in-situ tests, 209-210 Analytical model technique, 432, 438 Andersen's procedure, 342, 345,349-351 Arabian Gulf soils, 413 ASCE conference, 41 ASTM Standards D 422:385

More information

Measurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01

Measurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01 Measurement of In-Place Relative Density in Coarse Grained Alluvium for Comparison to Penetration Tests DSO-99-01 Department of the Interior Bureau of Reclamation Earth Sciences and Research Laboratory

More information

Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils

Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils Instrumented Becker Penetration Test for Liquefaction Assessment in Gravelly Soils Mason Ghafghazi 1, PhD, PEng. Jason DeJong 2, Professor Department of Civil and Environmental Engineering University of

More information

Estimation of Compression Properties of Clayey Soils Salt Lake Valley, Utah

Estimation of Compression Properties of Clayey Soils Salt Lake Valley, Utah Estimation of Compression Properties of Clayey Soils Salt Lake Valley, Utah Report Prepared for the Utah Department of Transportation Research Division by Steven F. Bartlett, PhD. P.E. Assistant Professor

More information

IN SITU GEOTECHNICAL TESTING USING LIGHTWEIGHT PLATFORMS. Peter Zimmerman, MSCE David Brown, P.G. Geoprobe Systems Salina, Kansas.

IN SITU GEOTECHNICAL TESTING USING LIGHTWEIGHT PLATFORMS. Peter Zimmerman, MSCE David Brown, P.G. Geoprobe Systems Salina, Kansas. IN SITU GEOTECHNICAL TESTING USING LIGHTWEIGHT PLATFORMS Peter Zimmerman, MSCE David Brown, P.G. Geoprobe Systems Salina, Kansas June, 1999 ABSTRACT In situ testing in geotechnical engineering has traditionally

More information

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL. STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill

More information

VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPORT CAPITAL REGION RESOURCE RECOVERY CENTRE

VOLUME III GEOLOGY, HYDROGEOLOGY & GEOTECHNICAL REPORT CAPITAL REGION RESOURCE RECOVERY CENTRE 2.0 SITE INVESTIGATION METHODOLOGY The following section summarizes the Site investigation methodology applied during the subsurface investigation and hydrogeological assessment completed at the CRRRC

More information

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum Malaysian Civil Engineering Standard Method of Measurement (MyCESMM) CLASS D: SITE INVESTIGATION WORK Measurement covered under other classes: Excavation not carried out for the purpose of soil investigation

More information

EXPERIMENT 10 CONSTANT HEAD METHOD

EXPERIMENT 10 CONSTANT HEAD METHOD EXPERIMENT 10 PERMEABILITY (HYDRAULIC CONDUCTIVITY) TEST CONSTANT HEAD METHOD 106 Purpose: The purpose of this test is to determine the permeability (hydraulic conductivity) of a sandy soil by the constant

More information

NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY

NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY Ilaria Giusti University of Pisa ilaria.giusti@for.unipi.it Andrew J. Whittle Massachusetts Institute of Technology ajwhittl@mit.edu Abstract This paper

More information

HAULBOWLINE, CORK STATIC CONE PENETRATION TESTS FACTUAL REPORT

HAULBOWLINE, CORK STATIC CONE PENETRATION TESTS FACTUAL REPORT HAULBOWLINE, CORK STATIC CONE PENETRATION TESTS FACTUAL REPORT CONE PENETRATION TESTS Cone resistance Local friction Porewater pressure Dissipations REPORT NO: RRM CONTRACT NO: GLOVER SITE INVESTIGATIONS

More information

Soil Behavior Type using the DMT

Soil Behavior Type using the DMT Soil Behavior Type using the DMT Peter K. Robertson Gregg Drilling & Testing Inc., Signal Hill, CA, USA. E-mail: probertson@greggdrilling.com Keywords: Soil Behavior Type, CPT, DMT ABSTRACT: The most promising

More information

Improvement in physical properties for ground treated with rapid impact compaction

Improvement in physical properties for ground treated with rapid impact compaction International Journal of the Physical Sciences Vol. 6(22), pp. 5133-5140, 2 October 2011 Available online at http://www.academicjournals.org/ijps ISSN 1992-1950 2011 Academic Journals Full Length Research

More information

PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS

PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS Proceedings of the Sixth International Conference on Asian and Pacific Coasts (APAC 2011) December 14 16, 2011, Hong Kong, China PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD

More information

CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A.

CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A. CPTic_CSM8 A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL J. A. Knappett (2012) This user s manual and its associated spreadsheet ( CPTic_CSM8.xls

More information

International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 ISSN 2229-5518

International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 ISSN 2229-5518 International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September-2013 409 Estimation of Undrained Shear Strength of Soil using Cone Penetration Test By Nwobasi, Paul Awo Department

More information

Penetration rate effects on cone resistance measured in a calibration chamber

Penetration rate effects on cone resistance measured in a calibration chamber Penetration rate effects on cone resistance measured in a calibration chamber K. Kim Professional Service Industries, Inc, Houston, TX, USA M. Prezzi & R. Salgado Purdue University, West Lafayette, IN,

More information

NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S.

NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS. Jeffrey A Farrar M.S. NEW DEVELOPMENTS AND IMPORTANT CONSIDERATIONS FOR STANDARD PENETRATION TESTING FOR LIQUEFACTION EVALUATIONS Jeffrey A Farrar M.S., P E 1 ABSTRACT Standard Penetration Tests (SPT) are often used for evaluating

More information

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1 Designation: D 3441 98 AMERICAN SOCIETY FOR TESTING AND MATERIALS 100 Barr Harbor Dr., West Conshohocken, PA 19428 Reprinted from the Annual Book of ASTM Standards. Copyright ASTM Standard Test Method

More information

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 5 : Geophysical Exploration [ Section 5.1 : Methods of Geophysical Exploration ]

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 5 : Geophysical Exploration [ Section 5.1 : Methods of Geophysical Exploration ] Objectives In this section you will learn the following General Overview Different methods of geophysical explorations Electrical resistivity method Seismic refraction method 5 Geophysical exploration

More information

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department

More information

CPT interpretation in marine soils less than 5m depth examples from the North Sea

CPT interpretation in marine soils less than 5m depth examples from the North Sea CPT interpretation in marine soils less than 5m depth examples from the North Sea R. Mitchell SEtech (Geotechnical Engineers) Limited, Great Yarmouth, England S. Wootton & R. Comrie SEtech (Geotechnical

More information

COSMOS 2012: Earthquakes in Action COSMOS 2012

COSMOS 2012: Earthquakes in Action COSMOS 2012 COSMOS 2012 What is SFSI and why is it important? Soil issues in Earthquakes Structures where SFSI important Retaining structures (lateral earth pressure) Foundations (spread and pile footings, bearing

More information

ALLOWABLE LOADS ON A SINGLE PILE

ALLOWABLE LOADS ON A SINGLE PILE C H A P T E R 5 ALLOWABLE LOADS ON A SINGLE PILE Section I. BASICS 5-1. Considerations. For safe, economical pile foundations in military construction, it is necessary to determine the allowable load capacity

More information

Electronic Soil Test Logging. Strategic Advantage or Unnecessary Headache?

Electronic Soil Test Logging. Strategic Advantage or Unnecessary Headache? 1 Electronic Soil Test Logging Strategic Advantage or Unnecessary Headache? 2 The Plan 3 4 What is it? Digitally Recording Soil Test Data Why? 5 6 Traditional Work Flow Field Digital Entry Sample Review

More information

Trenching and Shoring Procedures

Trenching and Shoring Procedures Trenching and Shoring Procedures Scope & Application This policy sets forth the official practices required for excavations General Requirements Soil Types Testing Methods Aluminum hydraulic shoring Benching

More information

Appendix D.1. Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils

Appendix D.1. Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils Appendix D.1 Testing Requirements for Infiltration, Bioretention and Sand Filter Subsoils General Notes Pertinent to All Testing 1. For infiltration trench (I-1) and basin (I-2) practices, a minimum field

More information

System. Stability. Security. Integrity. 150 Helical Anchor

System. Stability. Security. Integrity. 150 Helical Anchor Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair

More information

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary

More information

Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples

Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples Prof. V.S.Raju (Formerly: Director, IIT Delhi & Professor and Dean, IIT Madras) Email: rajuvs_b@yahoo.com

More information

CHAPTER: 6 FLOW OF WATER THROUGH SOILS

CHAPTER: 6 FLOW OF WATER THROUGH SOILS CHAPTER: 6 FLOW OF WATER THROUGH SOILS CONTENTS: Introduction, hydraulic head and water flow, Darcy s equation, laboratory determination of coefficient of permeability, field determination of coefficient

More information

Evaluation of Open Channel Flow Equations. Introduction :

Evaluation of Open Channel Flow Equations. Introduction : Evaluation of Open Channel Flow Equations Introduction : Most common hydraulic equations for open channels relate the section averaged mean velocity (V) to hydraulic radius (R) and hydraulic gradient (S).

More information

E4055. Quiz. Soil Classification. Name: SOIL CLASSIFICATION QUESTIONS

E4055. Quiz. Soil Classification. Name: SOIL CLASSIFICATION QUESTIONS E4055 Soil Classification Quiz SOIL CLASSIFICATION Name: Date: QUESTIONS 1 TRUE/FALSE 1. An average cave-in can drop five yards or 13,500 pounds of dirt. 2. A competent person should be knowledgeable of

More information

Table of Contents 10.1 GENERAL... 10.1-1

Table of Contents 10.1 GENERAL... 10.1-1 Table of Contents Section Page 10.1 GENERAL... 10.1-1 10.1.1 Overview... 10.1-1 10.1.2 Role of Uncertainty in Property Interpretation... 10.1-1 10.1.3 Role of Drainage in Property Interpretation... 10.1-2

More information

Soil Mechanics. Soil Mechanics

Soil Mechanics. Soil Mechanics Soil is the most misunderstood term in the field. The problem arises in the reasons for which different groups or professions study soils. Soil scientists are interested in soils as a medium for plant

More information

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY CETANZ Technical Report TR 1 Author(s) SJ Anderson, Geotechnics Ltd Report Date First Issue May 2010 Report Revision Date September 2011

More information

G-126 (Continued) MTA Westside Subway Extension Los Angeles, California. Figure: A-2.22c

G-126 (Continued) MTA Westside Subway Extension Los Angeles, California. Figure: A-2.22c LA METRO PBTUNNEL ZONE S:\131 GEOTECH\GINTW\LIBRARY MACTEC JUNE11.GLB G:\PROJECT_DIRECTORIES\43\\61_METRO_WESTSIDE_EXTENSION\6.2.3.1 GEOTECHNICAL DESIGN\3.2 ALL FIELD NOTES\GINT LOG\NEW TEMPLATE MARCH

More information

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering Geotechnical Bulletin GB 1 PLAN SUBGRADES Geotechnical Bulletin GB1 was jointly developed by the Offices

More information

DESIGN OF PILES AND PILE GROUPS CONSIDERING CAPACITY, SETTLEMENT, AND NEGATIVE SKIN FRICTION

DESIGN OF PILES AND PILE GROUPS CONSIDERING CAPACITY, SETTLEMENT, AND NEGATIVE SKIN FRICTION DESIGN OF PILES AND PILE GROUPS CONSIDERING CAPACITY, SETTLEMENT, AND NEGATIVE SKIN FRICTION Introduction Bengt H. Fellenius, Dr.Tech., P.Eng. Background Notes for Demo Example for UniPile at www.unisoftltd.com

More information

UNDER DRAINAGE AND FILTER DESIGN

UNDER DRAINAGE AND FILTER DESIGN UNDER DRAINAGE AND FILTER DESIGN Tailings and HLP Workshop 28 April to 1 May 2010 INTRODUCTION The internal drainage is of crucial importance to the reliability and safety of a tailings dam throughout

More information

Geotechnical Investigation Test Report

Geotechnical Investigation Test Report Geotechnical Investigation Test Report Report No. htsc/rcd/ 3457 Dated: - 20/03/2010 Asphalt Standard Penetration Test as per IS 2131 ------------- IS 6403 Soil Job Card No - 1649 Cement Client/Department

More information