DRY FILM THICKNESS GAUGES
|
|
- Carol Cook
- 7 years ago
- Views:
Transcription
1 Elcometer 157, mils. + 15% Pencil Pull-Off Probe, Ferrous Pre-calibrated, easy-to-use, ideal for spot check indications of coating thickness. Insensitive to hot and cold coatings or surfaces. Complies with ASTM D-1186 Elcometer 211 Manual Pull-Off Probe, A1E, Ferrous mils. + 5% 2E, Ferrous mils. + 5% 8E, Ferrous mils. + 5% Lightweight, portable and rugged, suitable for use in any environment. Complete with leather carrying pouch, Complies with ASTM D-1186, wrist strap and calibration foils. G 12, ASTM B 499, SSPC PA 2 Size: 9 x 2 x 1 Elcometer 300 Basic Models: Ferrous/Non-Ferrous F/NF mils. F + 1% 0-40mils NF + 1% Statistics Models: Ferrous/Non-Ferrous, 0-50 mils.f + 1% Printer Capability mils NF + 1% Options: Portable Printer w/cable n/a n/a Printer Cable n/a n/a Interface Lead to IBM PC n/a n/a ASCII Software and Cable n/a n/a Data Collection Software n/a n/a An accurate, simple, quick, non-destructive coating thickness gage. Manufactured of ABS plastic, the 300 is portable and lightweight. Complies with ASTM D-1186, Three models available. D-1400 Elcometer Key SSG Steel Structures Gage 2 Key, mils. + 3% Electronic Integral Probe Features include larger foot for better stability, auto-on, zero offset for rough surface calibration, tamperproof calibration, liquid crystal display and auto-off. Available in mil or micron Complies with SSPC PA-2 readout. 5
2 Elcometer Key Coating Thickness Gage Basic Models: 345F1, Integral Probe, Ferrous mils. + 3% 345F2, Integral Probe, Ferrous mils. + 3% 345F3, Electronic Separate Probe, mils. + 3% Ferrous 345N1, Electronic Integral Probe, mils. + 3% Non-Ferrous 345FN1, Electronic Integral Probe, mils. + 3% Ferrous or Non-Ferrous 345FNF1, Electronic Dual Separate mils. + 3% Probe, Ferrous/Non-Ferrous A microprocessor controlled digital dry film thickness gage for measuring protective coatings over ferrous or non-ferrous substrates. Compiles with ASTM D-1186; Available with either an integral or separate probe. D-1400 Gages read in mils or microns. Size: 2.2: x 4.75 Elcometer Key Statistical Model: 345F1, Separate Probe, Ferrous mils. + 3% 345F2, Separate Probe, Ferrous mils. + 3% 0-5mm 345F3, Separate Probe, Ferrous mils. + 3% 0-13mm 345N1, Separate Probe, mils. + 3% Non-Ferrous 345FN1, Separate Probe, mils. + 3% Ferrous / Non-Ferrous 345FNF1, Dual Probe, mils. + 3% Ferrous / Non-Ferrous Full statistics (mean, number of readings, standard deviation), memory (up to 16,000 readings) and built-in RS232 Compiles with ASTM D-1186; data output to printer or PC or HP IR D-1400 printer. Mils or micron readings. Elcometer 355 Digital Coating Thickness Gage System Ferrous/Non-Ferrous mils. + 1% The 355 Top model has all the Standard model features plus 28 keys to allow for user-defined batch identification, 10,000 reading memory capacity, high/low reasonable limits, password protection of calibration and set up, mean, standard deviation, highest and lowest reading, Compiles with ASTM D-1186; average and counted average mode. D-1400 Size: 6.9 x 3.3 x 1.6 6
3 Mikrotest Exacto Compact design for one-hand operation integrated probe. Three versions available Type F - Ferrous um + 3% Type N - Non-ferrous um + 3% Type FN - Combination F/NF um + 3% Mikrotest Models III and IV Coating Thickness Gage Compiles with ASTM B499; Model III: Accurate, portable, lightweight BS5411;ISO 2178,2361 measures non-magnetic coatings over ferrous substrates. Can be used on cylindrical parts. Manual Models: FM Pull-Off Type, Ferrous mils + 5% GM Pull-Off Type, Ferrous mils. + 5% D1186;G12,B530;DIN50981;50982 Model IV: Similar to Model III, except the dial moves and stops automatically, minimizing operator error. Automatic Models: FM Pull-Off Type, Ferrous mils. + 5% GM Pull-Off Type, Ferrous mils. + 5% S3M Pull-Off Type, Ferrous mils. + 5% S5M Pull-Off Type, Ferrous mils. + 5% Ni100 Automatic Type mils. + 5% Size: 8.25 x 2 x 1.25 Minitest 100/300 Coating Thickness Gage 100F, Digital Gage, Ferrous mils. + 2% 100N Digital Gage, Non-Ferrous mils. + 2% 100FN Digital Gage, Ferrous / Non-Ferrous mils. + 2% 300F Statistical Gage, Ferrous mils. + 2% 300N Statistical Gage, Non- Ferrous mils. + 2% 300 FN Statistical Gage, Ferrous / Non-Ferrous mils. + 2% Miniature lightweight digital coating thickness gages that measure all non-magnetic coatings applied to ferrous metal substrates. Model 300 has optional readings in microns or mils, a continuous measuring model, and audible signal for readings outside limits. Also on the Minitest Compiles with ASTM D memory for individual reads. Includes one 6V battery. Size: 125 mm x 27mm x 18mm 7
4 8 Minitest F Separate Probe, Statistical Gage, Ferrous mils. + 2% 600 N Separate Probe, Statistical Gage, Non-Ferrous mils. + 2% 600FN Separate Probe, Statistical, Ferrous / Non-Ferrous mils. + 2% Available as a read-only model (basic) or with an internal statistics package that computes and displays high/low values, number of readings, mean and standard deviation. Complete with probe and 9V battery. Size: 2.5 x 4.5 x 1 Minitest 1100, 2100 & 4100 Portable coating thickness gages for use on both ferrous and non-ferrous metal substrates. 10,000 reading memory capcity FN2 Dual Probe, Ferrous / Non-Ferrous mils. + 2% 2100 FN2 Dual Probe, Statistical Model mils. + 2% Probes: FN-3 Dual ferrous/non-ferrous mils. + 2% F-2 For paint, enamel, electroplating mils. + 2% F-06 Micro-probe for small parts mils. + 2% F-2/90 Right angle probe for tubes and pipes mils. + 2% F-10 For thick coatings and linings mils. + 2% F-20 For thick coatings and linings mils. + 2% N-2 For non-conductive coatings mils. + 2% N-2/90 Right angle probe for tubes and pipes mils. + 2% N-10 For thick coatings and linings mils + 2% N-20 For thick coatings and linings mils. + 2% N-100 For insulating coatings over F&N inches + 2% Model 4100 adds a wide range of additional statistical capabilities.includes dual probe, alkaline battery, and zero standard and calibration foils. D-1400 Compiles with ASTM D-1186; PosiPen A - Manual Pull-Off Type, Ferrous mils + 10% B - Manual Pull-Off Type, Ferrous Extreme temperatures to 450 o F mils + 10% Miniature pull-off gage measures Compiles with ASTM D-1186 non-magnetic coatings applied to ferrous SSPC PA-2 substrates. Dual mils/microns scale, Accuracy + 10% and 0.1 mil, and triple indicator. Complete with leather traceable to NIST pouch and certificate of calibration. Size: 5 1/2 long
5 PosiTector 100 B - Thin Coating mils. +0.1mils,+ 3% C - Thick Coating mils. +0.1mils,+ 3% D - Thick, Soft Coatings mils. +0.1mils,+ 3% Portable ultrasonic gage nondestructively measures single or multiple layer coating thickness on non-metallic surfaces. Model B is Compiles with ASTM D designed for measuring thin polymer coatings on non-metal substrates. Model C is the universal gage that can be user-adjusted to measure a variety of thick coating applications. Complete with plastic carrying case, AC adapter, certificate of calibration, ultrasonic gel and batteries. PosiTector 6000 Non-Magnetic Coatings on Ferrous Metals F - Electronic Integral Probe mils. + 1% FS - Electronic Separate Probe mils. + 1% F0S - Electronic Separate 0 o Probe mils. + 1% F45S - Electronic Separate 45 o Probe mils. + 1% F90S - Electronic Separate 90 o Probe mils. + 1% FT - Electronic Integral Probe, Thick Films mils. + 1% FHS - Electronic Separate Probe, Thick Films mils. + 1% Non-Conductive Coatings on Non-Ferrous Metals N - Electronic Ingegral Probe mils. + 1% NAS - Electronic Separate Probe, Thin Films mils. + 1% NS - Electronic Separate Probe mils. + 1% NOS - Electronic Separate Straight Probe mils. + 1% N45S - Electronic Separate 45 o Probe mils. + 1% N90S - Electronic Separate 90 o Probe mils. + 1% NHS - Electronic Separate Probe, Non-Ferrous mils + 1% Combination - All Metals FNS - Electronic Separate Probe, Ferrous / Non-Ferrous mils. + 1% FN - Electronic Integral Probe, Ferrous / Non-Ferrous mils. + 1% HP IR Wireless Printer The simplest way to print coating n/a n/a thickness measurements from PosiTector 100 and 6000 memory gages. Invisible infrared light is instantly beamed from the PosiTector directly to the HP IR. Uses standard 2 1/4 thermal paper. Powered by 4-AA batteries. Size: 7.3 x 3.6 x 2.5, Weight: 1 pound 9
6 PosiTest GM - Manual Pull-Off Type, Thin Films mils. + 5% FM - Manual Pull-Off Type, Ferrous mils. + 5% A magnetic coating thickness gauge for non-destructive measurement of Compiles with ASTM D-1186; non-magnetic coatings over ferrous A153,B499,B530,E376,BS5411, substrates. DIN50981,50982, , Size: 8 1/2 x 2 1/2 x 1 1/4 SSPC PA-2 QuaNix F1 - Separate Probe, Ferrous / mils % Non-Ferrous Statistical PC Printing Model Virtual gage connects to PC or laptop and in conjunction with QuaNix software has a complete test and documentation system for lab and production control. QuaNix 1200 Non-destructively measures coating mils. + 2% thickness over ferrous metal substrates. Lightweight, low-cost and durable, designed for easy, one-handed operation. The V groove facilitates measurements on curved surfaces. Thousands of measurements possible from one 9V battery (included). Automatic on/off, duplex LCD display. Appearance very similar to Size: 6 1/2 x 2 1/2 x 1 1/3 Weight: 5 0z. (including battery) QuaNix Integral Probe, Ferrous / Non-Ferrous mils % 1500M - Integral Probe, Ferrous/ Non-Ferrous with Memory mils % Low-cost portable coating thickness gage measures all non-magnetic coatings over both ferrous and non-ferrous metal surfaces. Two integrated probes enable the 1500 to Compiles with ASTM D-1186 measure virtually any application, and ASTM D-1400 even in hard-to-reach areas. Features include LCD display in mils and microns, carrying case and 9V battery. The 1500M also offers memory, block segmentation, instant averaging, and RS-232 download capability. Complete with software and patchcord. Size: 6 1/2 x 2 1/2 x 1 1/3, Weight: 5 oz. (including battery) 10
7 QuaNix 2200 and Digital Integral Probe, Ferrous mils. + 2% Digital Integral Probe, Non-Ferrous mils. + 2% Portable, battery-operated (9V) digital coating thickness gages measure all non-magnetic coatings over ferrous Compiles with ASTM D-1186 (2200) metal (2200) and non-ferrous metal Compiles with ASTM D-1400 (2300) (2300) substrates (aluminum, copper, etc.). Complete with carrying strap, carrier bag, zero-plate, and 9V battery. Available in mils or microns. Size: 2 x 4 1/2 x 1 QuaNix FN1 - Ferrous/Non-Ferrous Probe, Statistical Printing mils. + 2% Combines a hand-held measurement device and a printer all into one gage. Provides upper and lower tolerance settings, continuous readings, and calibration settings for special applications. Statistical evaluation including high/low, average standard deviation can be stored or printed out immediately. Values can be reviewed with the QuaNix software program or can be transferred into a statistical spreadsheet program. Size: 5 x 3 1/2 x 1 1/2 QuaNix Integral Ferrous Probe, Basic Model mils. + 2% Integral Non-Ferrous Probe, Basic Model mils. + 2% Integral Dual Ferrous & Non-Ferrous Probe mils. + 2% 7500 Underwater Probe, Ferrous or Non-Ferrous Statistical Model with 100 ft. cable mils. + 2% Versatile coating thickness gauge has the capability to measure coating thickness underwater using a remote probe (up to 200 feet) and topside gage. Measures non-magnetic coating thickness on both ferrous and non-ferrous metal surfaces by switching probes. 7500M with memory can hold up to 3,900 measurements in up to 999 blocks. Downloading capability to QuaNix software for statistical analysis also available. Complete with leather pouch and 9V battery. 11
8 Three types of dry film thickness gages are available: Magnetic pull-off, (Type I) for measuring non-magnetic coating thickness over ferrous metal surfaces. Electronic magnetic flux, constant pressure probe (Type II) for measuring non-magnetic coating thickness over ferrous metal surfaces. Eddy current gages for measuring non-magnetic coating thickness or non-ferrous metal surfaces. Helpful Hints - Dry Film Thickness Gages Calibration of magnetic gages should be done in accordance with SSPC-PA2, SSPC method for measurement of dry paint thickness with magnetic gages. Verify calibration of Type I gages before, during and after use, using NIST standard plates. Exposed magnets naturally attract iron fillings, steel grit, etc. Assure the magnet is free of contamination, including paint. Vibrations may prematurely lift the magnet from the surface, giving erroneous readings. Dial gages are susceptible to human error by continuing to turn the dial beyond the point the magnet lifts from the surface. Calibration of constant pressure probe gages should be done in accordance with SSPC-PA2, SSPC Method for Measurement of Dry Coating Thickness with Magnetic Gages. Verify calibration of Type II gages before, during, and after use, using either traceable standards (test blocks) or plastic shims (reference the manufacturer s instructions). Many electronic gages can be susceptible to flux leakage problems within a few inches from edges or corners. Eddy current gages for use on non-ferrous metals are calibrated using only the plastic shim method. Constant pressure probe gages are less susceptible to vibrations. CSI Coating Systems Inc. a Corrpro Company CSI provides complete protective coating systems engineering and application services. Experienced in all aspects of corrosion control, our approach is to investigate your corrosion problems and recommend coating solutions. CSI offers internal and external fusion bonded powder coatings, internal and external liquid systems, metallizing, fiberglassing, and plural component applications. Our extralarge 55 foot curing oven and automated in-line process equipment ensures efficient application. Our head office and shop facility is located in Nisku, Alberta, Canada. For maximum efficiency our 30,000 square foot facility is equipped with four 7.5 tonne overhead cranes, with craneways extending fully outside the building. Every project is inspected by CSI s full time NACE Certified Coating Inspector at critical hold points, as defined in our Quality Assurance Program, assuring the end product meets specification and is delivered on time. CSI maintains all records on each project for review and audit when requested. CSI s complete fleet of mobile equipment allows us to prepare the surface, coat, cure, and inspect coating applications at any site. Typical jobs include internal epoxy and/ or fiberglass reinforced linings and external coating of vessels and large diameter storage tanks. CSI also owns large indirect-fired heaters needed during cold weather jobs, so CSI can perform coatings in any season, on any size of storage tank. 12
Operating Instructions. Coating Thickness Gauges MINITEST 1001 MINITEST 2000
0 Operating Instructions Coating Thickness Gauges MINITEST 1001 MINITEST 2000 E L E K T R O - P H Y S I K Hans Nix & Dr Ing. E. Steingroever Pasteurstr. 15, D 5000 Koeln 60, Telefon 0221/765085, Telefax
More informationUnmatched Metal Hardness Testing
Unmatched Metal Hardness Testing The Equostat 3 hardness tester can be connected both to the portable Equotip 3 platform and directly to a PC, with graphic user guidance Hardness Measurements made easy
More informationULTRASONIC THICKNESS GAUGE TT100/110/120/130
ULTRASONIC THICKNESS GAUGE TT100/110/120/130 TT100 TT110 Portable size and easy operation Suitable for any metallic and non-metallic materials ultrasonic can go through Self-compensating of nonlinearity
More informationPosiTector. Coating Thickness Gages. INSTRUCTION MANUAL v. 7.0 for ALL models
PosiTector 6000 Coating Thickness Gages INSTRUCTION MANUAL v. 7.0 for ALL models Introduction The PosiTector 6000 hand-held, electronic Gage nondestructively measures the thickness of coatings on all metals,
More informationPortable Hardness Tester
Portable Hardness Tester Large, easy to read display with backlight Highly accurate ± 4 HL Automatic correction for impact direction Converts to all common hardness scales (,,,, HS, R m ) Light weight
More informationPaint Test Equipment. Holitech DC Holiday Tester Data Sheet
Paint Test Equipment Holitech DC Holiday Tester Data Sheet Coating Thickness Gloss Porosity Adhesion Surface Roughness Surface Cleanliness Climatic Conditions Electrostatic Inspectors Accessories Complies
More informationRon 3025 Crane Scale with 1"/25mm Display
Exceptionally small dimensions enable minimum headroom loss. For example: Height of the 5t load cell is 16.7 inch / 423 mm Optional shock absorbing protective cage Optional IR remote control Short delivery
More informationSpecification for Pipe Coating Repairs Offshore
Specification for Pipe Coating Repairs Offshore Specification for Pipe Coating Repairs Offshore 1 of 6 Table of Contents 1.0 SCOPE... 3 2.0 REFERENCE DOCUMENTS... 3 3.0 MATERIALS... 3 4.0 EQUIPMENT AND
More informationPosiTector. Coating Thickness Gages. Quick Guide v. 7.4
PosiTector 6000 Coating Thickness Gages Quick Guide v. 7.4 Table of Contents Introduction... 1 Quick Start... 1 Certification... 2 Probes... 4 Calibration, Verification and Adjustment... 7 Menu Operation...
More informationACL 395 Resistivity Meter
ACL 395 Resistivity Meter OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every 12 months. 840 W. 49 th Place Page 1 of 13 info@aclstaticide.com
More informationSpecifications for Programs: 737, 747, 757, 767, 777, 787
= Performed by GKN BAC 5000 AN General Sealing 6-262, 6-265, 6-267, 6-270 PSD for 787 Only: 6-242, 6-269, 6-271 PSD for 777 Only: 6-261,6-264, 6-266, 6-269, 6-271 BAC 5004 L Installation of Permanent Fasteners
More informationOPERATING INSTRUCTIONS
PIPELINE INSPECTION COMPANY LTD. OPERATING INSTRUCTIONS Wet Sponge Holiday Detectors 670,673, and MSRB Wet Sponge Holiday Detectors Portable and In-Plant Detectors Table of Contents General Information.......................3
More informationBB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
More informationACL 800 MEGOHMMETER OPERATION MANUAL
ACL 800 MEGOHMMETER OPERATION MANUAL Meter is warranted for one year from the date of purchase on parts and labor. Calibration is recommended every twelve months. NOTE: THIS MANUAL IS NOT TO BE SEPARATED
More informationEASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
More informationThickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical
Thickness Gauges Technical Data for Metric Thickness Gauges Page Model Lifting Contact points Contact points mm mm mm device standard available on request 130 K 15 0.1 10 15 no 6.35 mm Ø flat Ø flat, 130
More informationWEATHER STATION FOR SOLAR FARM MONITORING
WEATHER STATION FOR SOLAR FARM MONITORING SOLAR FARM MONITORING SYSTEM: Measures global, horizontal, & background irradiance. Measures wind speed, wind direction, ambient temperature, and relative humidity.
More informationGood Boards = Results
Section 2: Printed Circuit Board Fabrication & Solderability Good Boards = Results Board fabrication is one aspect of the electronics production industry that SMT assembly engineers often know little about.
More informationPipeline External Corrosion Analysis Using a 3D Laser Scanner
Pipeline Technology Conference 2013 Pipeline External Corrosion Analysis Using a 3D Laser Scanner Pierre-Hugues ALLARD, Charles MONY Creaform, www.creaform3d.com 5825 rue St-Georges, Lévis (QC), Canada,
More informationASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
More informationUltrasonic Reference Blocks
Ultrasonic Reference Blocks Custom and Standard Test Blocks for Nondestructive Testing Introduction 3 IIW Type 1 Calibration Block 4 Miniature Angle Beam (ROMPAS) Calibration Block 4 Distance Calibration
More informationBUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.
BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof. 1155 & 4155 LCL: Applies to all freight in less than container load quantities.
More informationPIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany
ABSTRACT: PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany Today, in-line inspection tools are used routinely
More information07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
More informationTENSIONMETER ** code 183_LNRSTW **
Electronic tension meter for applications in textile and wire industry. 9 Tension ranges from 0.1-200 cn to 5-50 dan. Versatile instruments usable for applications in textile industry: e. g. 50 up to max.
More informationTIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings.
Product Data Sheet SERIES 69 - DRYZINC ZINC-RICH PRIMER (69/90500) Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield system. Designed to impart superior corrosion protection to steel
More informationEasyTrack 2 Accessories List
EasyTrack 2 Accessories List DATA LOGGER ET6061 EasyTrack2 Data Logger (6 Channel) Measurement Range -150 to 500 C (-238 F to 932 F) Accuracy ±0.5 C (0.9 F). Type K thermocouple. 6000 readings per channel.
More informationThe L&J Engineering Model MCG 1500SFI Servo Gauge
PRODUCT DATA SHEET The is the most compact and lightest servo available today. Accuracy / repeatability of 1/32 inch (0.8mm) Product and Interface, custody transfer Wireless Infrared Calibration Advanced
More informationKit Highlights and Key Features
AF-OLK6 Series Fiber Optic Test kit (Data Storage Kit) Product: OLK6 Series Date: Aug:2007 Rev: 01 Description The AF-OLK6 series test kits are the complete solution necessary for the installer to test,
More informationAdvanced Systems Tester 900AST
Advanced Systems Tester 900AST Clear skies ahead with the 900AST TESTER The internal wiring in aircraft is under constant bombardment from age, vibration and moisture especially in airplanes that work
More informationZero peel strength of acrylic pressure sensitive adhesive is at about 45 C (-50 F).
PRODUCT BULLETIN Aluminum Polyimide Acrylic (3M 966) PSA First Surface Aluminum Coated Polyimide Tape with Acrylic 3M 966 Adhesive TAPES Sheldahl Brand Materials first surface aluminized polyimide tape
More informationGUARDRAIL POST STEEL
GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating
More informationOPERATION MANUAL INFRARED THERMOMETER
OPERATION MANUAL INFRARED THERMOMETER Features: Precise non-contact measurements Built-in laser pointer Automatic selection range and Resolution to 0.1ºor 1º / switchable button Automatic Data Hold & Auto
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationSUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
More informationBASIC SOUND LEVEL METERS
BASIC SOUND LEVEL METERS Typical Applications: Occupational Noise Measurements Noise Ordinance Enforcement Community Noise Assessment Fire & Emergency Notification Alarm Testing Maintenance Inspections
More information3D SCANNING SOLUTION FOR PIPELINE INTEGRIT Y ASSESSMENT!
NDT SOLUTIONS 3D SCANNING SOLUTION FOR PIPELINE INTEGRIT Y ASSESSMENT! CODE-COMPLIAN T PORTABLE 3D MEASUREMENT SOLUTIONS Pipeline operators and NDT service companies must deal with increasing pressure
More informationMultifunction HVAC and IAQ Meter
testo 435 Multifunction HVAC and IAQ Meter NEW! The newest technology for temperature, humidity, air flow and more! cfm P CO 2 %RH F Lux All the right parameters for HVAC and IAQ The testo 435 is perfect
More informationPurchasing Thermometers
L E S S O N 2 Purchasing Thermometers Lesson Objectives Getting Ready 1. Determine thermometer needs for each school kitchen or food production facility. 2. Develop and use specifications to purchase and
More informationTechCut 4 Precision Low Speed Saw
Product Brochure TechCut 4 Precision Low Speed Saw 3" - 6" Blade Range Digital Speed Display 1-Micron Sample Indexing Spring-Loaded Dressing Stick Attachment All Aluminum & Stainless Steel Construction
More informationInfrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL
RS Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL TABLE OF CONTENTS TITLE PAGE INTRODUCTION...1. SAFETY INFORMATION...2. FEATURES...4. SPECIFICATIONS...4.
More informationHeat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment
Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment Non-Destructive Examination Heat Exchanger Mechanical Repair Services
More informationMEASURING AND LEVELING TOOLS
MEASURING AND LEVELING TOOLS LASER LEVELING FAST AND ACCURATE LEVELING Earth moving, laying of floors, interior design and set up; all applications for our laser and optical levels to prove their accuracy,
More informationDual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42570 Introduction Congratulations on your purchase of the Model 42570 IR Thermometer. This Infrared thermometer measures and displays non-contact
More informationPaint Test Equipment. Stargloss Gloss Meter Data Sheet
Paint Test Equipment Stargloss Gloss Meter Data Sheet Coating Thickness Gloss Porosity Adhesion Surface Roughness Surface Cleanliness Climatic Conditions Electrostatic Inspectors Accessories Complies with
More informationWireless Data Logger Monitoring Systems
Wireless Data Logger Monitoring Systems Table of Contents About MadgeTech, Inc. Wireless Systems & Components Wireless Data Loggers 2000A Wireless Data Logger Models MadgeTech Cloud Services MadgeTech
More informationSECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 230529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.
More informationHow to Build a Printed Circuit Board. Advanced Circuits Inc 2004
How to Build a Printed Circuit Board 1 This presentation is a work in progress. As methods and processes change it will be updated accordingly. It is intended only as an introduction to the production
More informationConcrete 37 Compression machine accessories. ADR-Auto Console. Load Calibration Devices. Compression Machine Accessories
37 Compression machine accessories Compression Machine Accessories The selection and use of the correct accessories is essential if the range of machines described in Section 36 is to be utilised to its
More informationDREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
More informationINSTRUCTION MANUAL. Magna-Trak Series Magnetic Locator MT200 MT202. Magna-Trak 200 Series Magnetic Locator 1
INSTRUCTION MANUAL Series Magnetic Locator MT200 MT202 200 Series Magnetic Locator 1 Thank you for purchasing the Magnetic Locator. Please read this manual thoroughly before operation. CONTENTS 1. Introduction...
More informationE420 SHAFT ALIGNMENT. Entry level measurement and alignment system for rotating machines BUILT-IN WIRELESS UNITS LARGE COLOUR DISPLAY QUICK START
E420 BUILT-IN WIRELESS UNITS QUICK START 2 40 MIN. ROTATION LARGE COLOUR DISPLAY SHAT ALIGNMENT Entry level measurement and alignment system for rotating machines ENTRY LEVEL REDEINED! SETTING A NEW STANDARD
More information6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20
USE OF ELECTRICAL TEST EQUIPMENT Test equipment is necessary for determining proper set-up, adjustment, operation, and maintenance of electrical systems and control panels. The following is a general procedure
More informationSECTION 33 12 19 FIRE HYDRANTS
SECTION 33 12 19 FIRE HYDRANTS PART 1: GENERAL 1.01 SCOPE A. Fire hydrants. B. Adjustment of fire hydrants and gate valves. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 - Submittals.
More informationPORTABLE FLOW METER KITS TDS-100H
Transit Time Flow Meters TT-TDS-100H-HS ECEFast offers amazing prices on Transit Time Flow Meter portable kits. We are buying from the manufacturer who supplies 60% of the Chinese market and the majority
More informationSHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH
D505 D525 SHAFT ALIGNMENT Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE COMPENSATION THERMAL GROWTH TOLERANCE CHECK MEASUREMENT VALUE FILTER 40 MINIMUM ROTATION FOR ALL
More informationTECHNICAL REQUIREMENTS AND SPECIFICATIONS
TECHNICAL REQUIREMENTS AND SPECIFICATIONS REHABILITATION OF CONCRETE AND MASONRY MANHOLES OR UNDERGROUND VAULTS WITH A PROTECTIVE COATING (As Provided by Raven Lining Systems) FOREWORD This specification
More informationSECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
More informationSM-S200 SM-S300 SM-T300 3" 80mm rugged Mobile Printer with LCD display & WiFi version
NEW SM-S400 SM-T300DB Bluetooth and Serial without Magnetic Stripe Reader SM-T301DB Bluetooth with MSR SM-T301DW WiFi version with MSR SM-T300 SM-S200 SM-S300 Mobile Printers Fast, lightweight and small.
More informationPIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
More informationPRODUCT DATA SHEET DESCRIPTION:
DESCRIPTION: SP-9888 Pipe Lining is based on the latest Zero VOC Novolac Technology. The product cures to a highly cross-linked coating with excellent chemical, solvent and water immersion resistance.
More informationA. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.
POLYURETHANE COATING ON STEEL PIPE PART 1 -- GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents. 1.2 REFERENCE SPECIFICATIONS,
More informationMicrowave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
More informationGuide to adhesively mounting accelerometers
Guide to adhesively mounting accelerometers cmyk Guide to adhesively mounting accelerometers Purpose This technical paper identifies and clarifies issues regarding adhesive mounting of accelerometers.
More informationRS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
More informationPAT Tester Printers and Barcode Scanners
PAT Tester Printers and Barcode Scanners Test n Tag Elite An extremely rugged battery powered mobile printer which prints durable synthetic asset labels. Long battery life and high impact resistance make
More informationList of Frequently Utilized Storage Tank Standards and Practices
List of Frequently Utilized Storage Tank Standards and Practices Below is a list of frequently used storage tank standards and practices from organizations that are referenced in 25 PA Code, Chapter 245.
More informationT H A N K S F O R A T T E N D I N G OUR. FLEX-RIGID PCBs. Presented by: Nechan Naicker
T H A N K S F O R A T T E N D I N G OUR TECHNICAL WEBINAR SERIES FLEX-RIGID PCBs Presented by: Nechan Naicker We don t just sell PCBs. We sell sleep. Cirtech EDA is the exclusive SA representative of the
More information- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
More informationInsulation resistance testing. A complete solution for every person.
Insulation resistance testing. A complete solution for every person. Insulation resistance. The latest test tools from the testing experts. You asked. We responded. Now you have more insulation testing
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationCommercial Semi-Instantaneous Water Heaters
FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory
More informationManage QA/QC department for onshore and
QA/QC & safety consultancy services Training services We provide consultancy services in QA/QC, safety and RBI services which include: NDT consultancy services Welding consultancy services RBI services
More informationSECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
More informationFlow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationEA-04/15. Accreditation. For Non-Destructive. Testing. Publication. Reference. EA - 4/15 Accreditation for Non-Destructive Testing PURPOSE
Publication Reference EA-04/15 Accreditation For Non-Destructive Testing PURPOSE This publication provides detailed guidance for organisations carrying out non-destructive testing as an accredited activity
More informationOperating Principle of the Sample Positioning Flaps
Test WEIGHT, THICKNESS, DIAMETER (or LENGTH), and HARDNESS of regular tablets, odd shaped tablets (caplets, oblongs etc.) and other solid samples fully automatically. Use the WHT 3ME for the fully automated
More informationMeasuring electric and magnetic fields
NARDA BROADBAND FIELD METER NBM-520 Measuring electric and magnetic fields ranging from high frequency to microwaves Non-directional measurement using isotropic probes for applications in the frequency
More informationSECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES
1.00 PART 1 GENERAL 1.01 SCOPE A. It is the intent of this contract to install a 100% solids epoxy monolithic coating to the walls, benches and inverts of all manholes and the specified surfaces of other
More informationO C M III. Open Channel Flow Monitor
O C M III Open Channel Flow Monitor Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow transmitter with sensor and temperature compensation probe. B. Under this
More informationSTANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
More informationHOT BAR REFLOW SOLDERING FUNDAMENTALS. A high quality Selective Soldering Technology
HOT BAR REFLOW SOLDERING FUNDAMENTALS A high quality Selective Soldering Technology Content 1. Hot Bar Reflow Soldering Introduction 2. Application Range 3. Process Descriptions > Flex to PCB > Wire to
More informationAC Tech Project Survey
AC Tech Project Survey PROJECT NAME: DATE: PROJECT SIZE: EST. START DATE: I. Overview Successful projects depend on accurate and detailed information. The AC Tech Approved Applicator must obtain and record
More informationCONTROLTECH INDUSTRIAL TORQUE WRENCH
TOOLS AND SOLUTIONS FOR CRITICAL INDUSTRIES E R O M ES SIZLABLE! I AVA CONTROLTECH INDUSTRIAL WRENCH IN LESS TIME, WITH MORE ACCURACY AND CONTROL Snap-on ControlTech Industrial Electronic Torque Wrenches
More informationSpecifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
More informationDual Laser InfraRed (IR) Thermometer with Color Alert
User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer
More informationDual Laser InfraRed (IR) Thermometer
User s Manual Dual Laser InfraRed (IR) Thermometer MODEL 42511 Introduction Congratulations on your purchase of the Model 42511 IR Thermometer. This Infrared thermometer measures and displays non-contact
More informationTARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
More informationInstruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements
Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationWide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer
User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer
More informationHigh Temperature InfraRed Thermometer with Laser Pointer
User s Manual High Temperature InfraRed Thermometer with Laser Pointer MODEL 42540A 6 42540 6 Introduction Congratulations on your purchase of the Model 42540A IR Thermometer. The 42540A is capable of
More informationInstruments for the oil & gas industry
Instruments for the oil & gas industry Instruments high-quality instruments make the difference The ROSEN Group supports industries, with a focus on integrity and maximizing asset lifespan. Our wide range
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationDrum Dispensing Stations
Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed
More informationMelting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
More informationSection 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
More informationOXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system
Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can
More informationTremco Fire Protection Systems Group Technical Bulletin
Compartmentalization products and design play a key role in protecting lives and property from fire. Understanding the tools and techniques available for firestopping is of utmost importance to designers,
More informationEVEN FOR SMALL QUANTITIES WE GET STARTED RIGHT AWAY...
EVEN FOR SMALL QUANTITIES WE GET STARTED RIGHT AWAY... Because we produce in-house, so we don t have far to go. Our decisions are not based on when and who can do what in Asia; instead, we look at what
More information