Irrigation Quotation. Prepared For: LUKE S LANDSCAPING 20 MERINO COURT, THORNLIE WA 6108 ATTENTION: LUKE MOB: TH OCTOBER, 2013
|
|
- Noel Gilbert
- 7 years ago
- Views:
Transcription
1 Reece Irrigation Canning Vale 188 Banister Road, CANNING VALE, WA 6155 Tel: (08) Fax: (08) TH OCTOBER, 2013 Irrigation Quotation Prepared For: LUKE S LANDSCAPING 20 MERINO COURT, THORNLIE WA 6108 ATTENTION: LUKE MOB:
2 The Project We herewith submit the following quotation for the design & supply only of an automatic irrigation system at 62 Crawshaw Crescent, Manning, as per the drawings supplied and discussions with the Canning Vale branch. Items Requiring Consideration Please note the following items that will need to be checked &/or confirmed prior to accepting this quotation; Please note the entire above quote has been based on a flow rate of ten (10) litres per minute at an operating pressure of 300kPa generated via the mains connection point. This is an assumed flow rate and will need to be checked and confirmed prior to installation commencing. That at the end of this document, we have provided you with a Weathermatic Savings Calculation. This calculation demonstrates the how much you could likely save by switching from time-based to weather-based irrigation. Please refer to the optional pricing provided for a weather-based controller & weather station combination, or contact your local Reece Irrigation branch for further information. We have assumed that there is an existing 20mm dia. isolation valve allowed for irrigation in which to connect the master valve to this will need to be confirmed prior to installation taking place. We have assumed that access is available for pipework/multi-core cable when running under hard surfaces is required. Please note we have assumed that there is little or no elevation across the areas to be irrigated. This should be confirmed prior to accepting this quote as any significant elevations may result in a re-quote.
3 Product Selection The following equipment is included in this irrigation system: Netafim Landline 8 (Miniscape) 2.0 LPH dripline (with built in anti siphon device to prevent suckback, reducing the possibility of dripper blockages) with 0.15 metre spacing inline drippers have been allowed for all the garden bed adjacent to the house entrance 0.3m row spacing. Please note the drip-line stations are to incorporate 20mm screen filters and 20mm PRV s encased in suitably sized residential valve boxes for location and maintenance purposes. QTY: 25m Line-flushing valves (15mm) have been allowed to rid unwanted debris in the system on initial start-up of the system to be installed at the lowest positions within the zones housed in suitable sized valve box. QTY: 1 Air-release valves (15mm) have been allowed to release air eliminating vacuum that could draw contaminants into the drippers or piping system once the control valve has been turned off to be installed at the highest positions within the zones housed in suitable sized valve box. QTY: 1 Single piece HR-JS12 Jet Sprays fitted on 200mm in length 4mm risers have been used in the rear garden areas throughout the site. QTY: 16 Hunter Pro Spray 300mm pop up sprays fitted with 300mm in length articulated risers and Nelson MP Rotators have been used for the garden bed areas in the front garden surrounding the water feature. QTY: 16 Hunter Pro Spray 300mm pop up sprays fitted with 300mm in length articulated risers and Nelson MP Rotators have been used for the turf areas throughout the turf area surrounding the water connection point. QTY: 8 Enki Pro 100mm pop up sprays fitted with 300mm in length articulated risers and Nelson MP Rotators have been used for the remaining turf areas throughout the site. QTY: 26 Weathermatic model series 25mm dia. solenoid valves with flow control have been allowed for the automatic operation of the system. These will be encased in suitably sized residential valve boxes. QTY: DVT Rainbird valve (Master valve) ( includes 1 x extra valve for Water feature )
4 Control unit to consist of a Weathermatic SL1600 modular irrigation controller that comes complete with durable plastic lockable cabinet that can be housed outdoors. This comes as a 4-station unit, and is expandable through the use of 4-station upgrade modules the unit is capable of becoming a 16- station unit. All associated fittings including low-voltage electrical cable (100.0m only) and heatshrink joiners have been allowed for the automatic operation of the system. QTY: 1 unit + 3 modules = 16 stations. Mainline to consist of 25mm class 9 upvc, with laterals to the turf areas and front garden bed to consist of 20mm class 12 upvc and laterals to the garden areas to consist of 25mm LDPE. Connection into the Miniscape dripline via take-off connectors. All associated fittings including priming fluid (red), solvent cement (green) and teflon tape (white). QUOTATION #: Supply only of irrigation components as described above. $ 5, $ $ 5, Estimated Installation: (for trenching purposes) 55 metres (Mainline pipework upvc) 25 metres (Sub-main pipework ( garden ) LDPE) 45 metres (Lateral pipework (garden) - LDPE 160 metres (Lateral pipework (garden & turf) - upvc) Please note the entire above quote has been based on a duty of ten (10) litres min at an operating pressure of 300kpa at the water connection point. This is an assumed flow rate and will need to be checked and confirmed prior to installation commencing. The quotation sets out the costs involved and is valid for a period of thirty days from the date herewith and is thereafter subject to confirmation. Quoted prices are subject to rise and fall in accordance with suppliers recommended prices or Government levied increase without notice. Please note cartage fees will be applied per delivery for local deliveries Metro (POA) and outer Metro (POA). This quotation incorporates by reference our standard Terms & Conditions of Sale, which form part of all trading with Reece. These are endorsed on the back of this quotation and/or available on request. The above quotation has been prepared based on creating a Bill of Materials from the irrigation plan as per normal irrigation practices with some extra fittings being incorporated, however, this does not allow for unforeseen circumstances where extra fittings may be required. We trust that we have interpreted your requirements satisfactorily, however, should you require additional information regarding this quotation, please do not hesitate to contact the undersigned at REECE IRRIGATION (Canning Vale) Ph: (08) Fax: (08)
5 Please note a full irrigation layout will be provided should we be successful on the above quotation, which would be available using computer-aided technology and the plan would also be laminated. Also note the plan may take approximately 3-4 working days to complete unless discussed prior with the Irrigation Design Department. If As-Constructed or Shop drawings are to be provided to your client, we can provide these at an additional charge please contact the undersigned to discuss this further. Thank you for giving us the opportunity to submit this proposal. Yours sincerely, Leigh Evans MANAGER CANNING VALE
6 HUNTER PROS-12 model 300mm POP-UP used throughout this turf area W IC REECE PTY LTD SYSTEM DUTY: PIPE LEGEND: SPRINKLER / VALVE LEGEND: A CLIENT: DATE: DESIGNED BY: PROJECT ADDRESS: SCALE: IC W ORIENTATION: CANNING VALE BRANCH 188 BANNISTER ROAD, CANNING VALE WA 6155 NO. DATE REVISIONS BY DRAWING No.: 10 LITRES PER AN OPERATING PRESSURE OF 300 KPA NETAFIM MINISCAPE m 0.3m ROWS 20mm CLASS 12 UPVC LATERAL PIPEWORK ( NOT SHOWN ) 25mm LDPE SUB-MAIN PIPEWORK ( NOT SHOWN ) 25mm CLASS 9 UPVC MAINLINE PIPEWORK JET SPRAY w/ 180º MICRO SPRAY JET SPRAY w/ 90º MICRO SPRAY HUNTER PROS-12 model 300mm POP-UP (var.) w/ MP SIDE STRIP noz. HUNTER PROS-12 model 300mm POP-UP (var.) w/ MP RIGHT STRIP noz. HUNTER PROS-12 model 300mm POP-UP (var.) w/ MP LEFT STRIP noz. HUNTER PROS-12 model 300mm POP-UP (var.) w/ MP1000 noz. ENKI model PR04 POP-UP SPRAY (var.) w/ MP1000. noz. ENKI model PR04 POP-UP SPRAY (var.) w/ MP2000. noz. ASSUMED LOCATION OF IRRIGATION CONTROL UNIT LOCATION OF MAINS WATER SUPPLY PRELIMINARY DRAWING ISSUED LUKE'S LANDSCAPING _IR01_A_(PD) CHECKED BY: RP TK 62 Crawshaw Crescent Manning WA 1 : A3 REECE IRRIGATION IS A MEMBER OF THE FOLLOWING ASSOCIATIONS IN WA: T: F: RP W N S E PRELIMINARY DRAWING REECE PTY LTD RESERVES ALL RIGHTS IN ITS DESIGNS, DRAWINGS, SPECIFICATIONS & PLANS. THEY MAY NOT BE REPRODUCED OR OTHERWISE COPIED WITHOUT THE WRITTEN AUTHORISATION FROM REECE PTY LTD. THIS DRAWING MUST BE READ IN CONJUNCTION WITH THE OTHER CONTRACT DOCUMENTS & ANY INSTRUCTIONS ISSUED DURING THE COURSE OF THE PROJECT. CONTRACTORS SHOULD VERIFY ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO ANY COMMENCEMENT OF IRRIGATION WORKS. IF ANY DISCREPANCIES ARE FOUND, BRING THESE IMMEDIATELY TO THE ATTENTION OF THE IRRIGATION DESIGNER. PRIOR TO COMMENCEMENT OF IRRIGATION WORKS, A FLOW TEST AND PRESSURE TEST SHOULD BE PERFORMED ON SITE TO CONFIRM SYSTEM DUTY. IF SYSTEM DUTY IS NOT REACHED, A RE-DESIGN MAY BE REQUIRED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND SERVICES PRIOR TO COMMENCING ANY EXCAVATION WITH ALL RELEVANT AUTHORITIES. DISTANCES BETWEEN OUTLETS, VALVES, FITTINGS & THE LIKE ARE INDICATIVE ONLY AND MAY BE ALTERED BY THE CONTRACTOR / INSTALLER AT THEIR DISCRETION.
7 Weathermatic Savings Calculator Reece Irrigation Page 1 of 3 8/10/2013 Weathermatic Irrigation Calculator A smarter way to save Conventional timer-based systems water on weekly schedules that once programed, are rarely changed. Because of this, they tend to over-water by 20-60%. They also do not take into account seasonal, soil, plant and weather conditions. Over-watering injures plants and creates runoff that can lead to costly damage to paths and driveways. The SmartLine system is the world's leading weather-based controller and adjusts water levels instantly to changing weather conditions helping you reduce your water usage and bills and keep your landscape in peak condition. Our online calculator will help calculate how much you could save by switching from time based to weather based irrigation. Your Summary Site Details Location Perth, WA Landscape Area 317m 2 Months Irrigated January February March October November December Time Based Irrigation Irrigation 100 Minutes per week. Water Consumption 34 kl per month. Water Cost $ per month. Weather Based Irrigation Turf & Plants Warm Season Turf (Couch, Kikuyu) (Local Sports Turf / Commercial Turf) 70% Shrubs 30% System Efficiency Designed by Irrigation Consultant/Designer Water Consumption 8.62 kl per month (average). Water Cost $17.59 per month (average). Savings with Weathematic $ per year kL per year 74.66% of current water consumption. Contact your nearest Reece Irrigation branch for more information - Disclaimer: Actual savings will vary based on weather, water rates, historical watering practices and overall sprinkler system efficiency.
Sample Punch List. Garth Ruffner Landscape Architect (916) 797-2576. Page 1 of 5
Sample Punch List This document is provided primarily for landscape contractors who have not previously worked with Garth and would like to know what issues are frequently addressed by site observation
More informationDISTRIBUTION CONNECTION
DISTRIBUTION CONNECTION POLICY Page 1/15 TABLE OF CONTENTS 1 Introduction... 3 2 Acceptance of requests for a connection... 3 2.1 Who can request a connection... 3 2.2 How to request a connection... 4
More informationGEBCO (PTY) LTD - Netafim Product List - 1st August 2011
AQUANET PLUS & ITEC CONTROLLERS Globe - Solenoid, Manual Override and Mechanical Throttle Aquanet Valve - DC 20 mm BSP Valve (Solenoid Valve) 34500-001000 Aquanet Valve - DC 25 mm BSP Valve (Solenoid Valve)
More informationWaterwise Display Village Program
Waterwise Display Village Program The Waterwise Display Village Program offers the housing industry and new homebuyers the opportunity to play an important role in conserving our State's water supply.
More informationLawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version 2009 1382 Roseland Drive Macedonia, Ohio 44056 800.435.4979 www.rilawnsprinklers.
Lawn Sprinkler Systems Reserve Irrigation Inc. O & M Version 2009 1382 Roseland Drive Macedonia, Ohio 44056 800.435.4979 Table of Contents Spring Maintenance of Irrigation system Page 1-9 Summer Maintenance
More informationNote: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.
CHANNEL DrAiNS Durable Designed for maximum durability and drainage, NDS Channel Drains are a proven alternative to traditional concrete drains. UV inhibitors in the grates, channel and component parts
More informationBeacon Hill Sewer District Standard Specifications
Beacon Hill Sewer District Standard Specifications Residential Gravity Side Sewer Including Design Criteria and Standard Construction Drawings Residential Gravity Side Sewer Design Criteria 1. Provisions
More informationCONGRATULATIONS! HERE S YOUR H2OUTLINE SPRINKLER DESIGN
CONGRATULATIONS! HERE S YOUR H2OUTLINE SPRINKLER DESIGN Rain Bird professionals have designed your custom sprinkler system to the highest standards in the industry. Why? It s the best, most efficient way
More informationProtector del Agua. Residential Irrigation Systems
Protector del Agua Residential Irrigation Systems ACKNOWLEDGEMENTS Originally developed for of Southern California By Derek Stucki Updated material provided by WaterWise Consulting TABLE OF CONTENTS The
More informationDrip Irrigation for the Yard and Garden
Drip Irrigation for the Yard and Garden R. Troy Peters, Ph.D. WSU Extension Irrigation Engineer Drip irrigation has many advantages over sprinklers. The application efficiency of sprinklers is typically
More informationCITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT
Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide
More informationTips and Facts. What We Will Cover
09 09 Tips and Facts When minor issues arise with a drip irrigation system, there is often a quick fix if you know how to spot the problem. In this section, we will cover the most common problems that
More informationGas Meter Clearances and Service Installation Requirements
March 2016 Gas Meter Clearances and Service Installation Requirements Builder/Owner/Developer Requirements Call PSE's Customer Construction Services 1 888 321 7779 or visit PSE.com/CustomerConstruction
More informationStandard terms and conditions
Standard terms and conditions INTRODUCTION For the provision of a water service (Water Supply, Wastewater and Drainage) Under Section 73(2)(a) of the Water Services Act 2012, landowners may be entitled
More information9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems
9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES Hunter Underground Systems 9.01 General 9.02 Surface water Drainage 9.03 Groundwater Drainage 9.04 Dispersal of Septic Tank Effluent 9.01 The use of
More informationPotted Plant Watering Systems
N E T A F I M U S A Potted Plant Watering Systems A Labor Saving Drip System for Watering Potted Plants A Low Cost Potted Plant Watering System That Saves Labor 4-Way MOD System Production Tool Comparing
More informationPART 5 : WASTEWATER DRAINAGE
Authorised by : City Waters Unit Manager Page 1 of 15 PART 5 : WASTEWATER DRAINAGE 5.1 INTRODUCTION This Manual sets out the basic design principles for drainage of wastewater. While some construction
More informationPotted Plant Watering Systems
N E T A F I M U S A Potted Plant Watering Systems A Labor Saving Drip System for Watering Potted Plants A Low Cost Potted Plant Watering System That Saves Labor 4-Way MOD System Production Tool Comparing
More informationPART 4: SITE INFORMATION
TRANSNET PIPELINES TENDER NUMBER: PYP/W1/6/21/1646 DESCRIPTION OF THE WORKS: CONSTRUCTION OF THE FIRE PROTECTION SYSTEM UPGRADE FOR THE FUEL HANDLING AREAS OF THE TARLTON DEPOT AND IRP REFRACTIONATOR ONLY
More informationPAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL
PAINT REMOVAL SYSTEM PAINT REMOVAL SPECIFICATION SAFE WORK METHOD STATEMENT FOR LEAD PAINT REMOVAL CONTENTS: 1.0 AWARENESS AND PRECAUTION 2.0 TEST SAMPLING & REMOVAL EVALUATION 3.0 SITE EVALUATION 4.0
More informationRiver Friendly Landscape Program Frequently Asked Questions (FAQs) February 2016
1. What plants can I use in my water-efficient landscape? The River Friendly Landscape Rebate Program does not require particular plants, only that when fully mature, the plants cover at least fifty percent
More informationDo It Yourself Sprinkler System Checkup Guide
Did You Know. Watering lawns and landscape plants can account for up to 50% of an average homeowner s total water use. Watering a typical 5,000 square-foot yard with an in-ground sprinkler system could
More informationProving that extra smart can also be extra simple.
ESP-SMTe Smart Control System Proving that extra smart can also be extra simple. Smart Technology has reached its tipping point. Other smart controllers claim simplicity and precision; the Rain Bird ESP-SMTe
More informationCHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING DEVELOPMENT WITH OPEN SPACE PROVISION
1 General NPARKS-0-DCS03 CHECKLIST FOR DC SUBMISSION - CONVENTIONAL HOUSING (a) The following plans are provided: Key and location plans of scale 1 : 10,000 or 1 : 5,000 showing access to the site from
More information138.255 Section 4 Page 2. Flow in Pipes
Flow in Pipes 138.255 Section 4 Page 2 Flow in Pipes 1.0 INTRODUCTION In this module we are focusing on the fundamental principles of headloss and we learn how to use headloss charts to estimate the headloss
More informationIntroduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References
Introduction General This Technical Booklet has been prepared by the Department of the Environment for Northern Ireland and provides for certain methods and standards of building which, if followed, will
More informationGROUNDS MAINTENANCE-WATER USE DFC Environmental Management System
1.0 Purpose To reduce the amount of water applied to the DFC Grounds in order to conserve water. 2.0 Activity/Department The On-site Landscape Contractor GSA Team 6 3.0 Forms Used Contractor s Daily Quality
More informationIrrigation System Maintenance
November 2004 HG/Irrigation/2004/01 Irrigation System Maintenance Kelly Kopp, Extension Water Conservation and Turfgrass Specialist, and Jennie Hoover, Water Conservation Specialist, Center for Water Efficient
More informationDESIGNING YOUR LANDSCAPE
DESIGNING YOUR LANDSCAPE SITE AND NEEDS ASSESSMENT Examine all existing features of your site that could affect your landscape design and then identify the functions you want your landscape to serve. Site
More informationWATER MANAGEMENT STRATEGIES FOR URBAN TREES IN AN UNCERTAIN ENVIRONMENT
WATER MANAGEMENT STRATEGIES FOR URBAN TREES IN AN UNCERTAIN ENVIRONMENT GEOFF CONNELLAN INTRODUCTION The vulnerability and dependence of urban landscapes on supplementary watering has become evident in
More informationLayout Guide. Easy, step-by-step, underground sprinkler system layout guide FREE SPRINKLER SYSTEM DESIGN. See page 5 for details
07WTM003045 53251-01 re.qxd 3/2/07 2:30 PM Page 1 Layout Guide Easy, step-by-step, underground sprinkler system layout guide FREE SPRINKLER SYSTEM DESIGN See page 5 for details Planning & Design Flow 3/4
More informationBUILDING OVER OR NEAR WATER & SEWER MAINS POLICY
MURRAY SHIRE COUNCIL BUILDING OVER OR NEAR WATER & SEWER MAINS POLICY ADOPTED: 1 May 2012 1 BUILDING OVER OR NEAR WATER AND SEWER MAINS POLICY CONTENTS 1. Objective... 2 2. Requirements for Building Near
More informationCITY OF BEAVERCREEK, OHIO QUOTES FOR MOWING AND GENERAL CLEANUP OF PRIVATE PROPERTIES
CITY OF BEAVERCREEK, OHIO QUOTES FOR MOWING AND GENERAL CLEANUP OF PRIVATE PROPERTIES The City of Beavercreek is seeking quotes for mowing, trimming and general cleanup of private properties found to be
More informationDesign Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)
Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) 1. In addition to the information scheduled below, the pre-tender designer is responsible for: (i)
More informationModel Number(s): SRC, SRC Plus, Pro-C, ICC, XCORE, icore
Integration Note Manufacturer: Hunter Industries Model Number(s): SRC, SRC Plus, Pro-C, ICC, XCORE, icore Minimum Core Module Version: Document Revision Date: 5/13/2013 OVERVIEW AND SUPPORTED FEATURES
More informationHow To Safely Dig For Natural Gas
PNG DIAL B4-U-DIG book_final_nu 5/1/05 3:24 PM Page 2 Phoenix Natural Gas,197 Airport Road West, Belfast BT3 9ED. Tel. 08454 55 55 55. www.phoenix-natural-gas.com PNG DIAL B4-U-DIG book_final_nu 5/1/05
More informationAUTOMATION IN DRIP IRRIGATION SYSTEM FOR COTTON GROWING ON LARGE SCALE - A CASE STUDY
AUTOMATION IN DRIP IRRIGATION SYSTEM FOR COTTON GROWING ON LARGE SCALE - A CASE STUDY S.M. Taley R.S. Patode 2 A.N. Mankar 3 ABSTRACT Micro Inigation technology concept is now accepted by most of the farmers
More informationLeakage Code of Practice. Domestic Customers
Leakage Code of Practice Domestic Customers A Leakage Code of Practice Domestic Customers The advice in this Leakage Code of Practice is important and has been approved by the Water Services Regulation
More informationModel F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
More informationWATERING OF STREET TREES: THEORY AND PRACTICE For Presentation at Irrigation Australia 2008 Conference Tuesday 20 May 2008
WATERING OF STREET TREES: THEORY AND PRACTICE For Presentation at Irrigation Australia 2008 Conference Tuesday 20 May 2008 Geoff Connellan G & M Connellan Consulting, Lower Plenty, Vic. Ian Shears Team
More information5000 Series Rotors 5000, Plus, PRS, SAM
Tech Spec 00 Series Rotors 00, Plus, PRS, SAM Built from top to bottom with the contractor in mind, the Rain Bird 00 Series product line is the durable, reliable rotor for residential and commercial applications.
More informationLEAKING SUPPLY PIPE? YOUR GUIDE TO WATER SUPPLY LEAKS. You were out when we visited today.
LEAKING SUPPLY PIPE? YOUR GUIDE TO WATER SUPPLY LEAKS You were out when we visited today. Check the back of this leaflet to find out why we called and what happens next. NW FSM3-1/15 INTRODUCTION Helping
More information2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS
2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS Water system improvements proposed for inclusion into Western s service area shall be designed in accordance with all appropriate AWWA standards, include
More informationGas Meter Clearances and Service Installation Requirements
March 2015 Gas Meter Clearances and Service Installation Requirements Builder/Owner/Developer Requirements Call PSE s Customer Construction Services 1-888-321-7779 or visit PSE.com/CustomerConstruction
More informationElectricity to your property
Vattenfall Distribution AB Electricity to your property How an electrical connection is made and what you need to consider How electricity reaches your property 8 simple steps! 1. Please leave plenty of
More informationDo it Right. Save More.
Commercial Outdoor Water Management Solutions Smart Irrigation Management Do it Right. Save More. Do it Right WeatherTRAK is the all-in-one solution proven to deliver the greatest savings year after year.
More informationHow To Install An Overhead Sewer
Village of Broadview Flood Control Assistance Program Village of Broadview 2350 S. 25 th Avenue, Broadview, IL 60155 INTRODUCTION The Village of Broadview is served by combined sewers which carry sewage
More informationINDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION
INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions
More informationpart 9 waste management
part 9 waste management 30m Hammerhead T-form 22m 21m Hammerhead Y-form 30m 18m Forward Side-Turn 25m 15m Reverse Side-Turn 30m Above: Recommended turning circles for waste collection vehicles 9 WASTE
More informationHow To Wire Wire Wire For A Decoder System
The Paige Irrigation Wiring Guide for Systems Background: The decoder system was first introduced to the irrigation industry in the late 1960s. It was invented by the world renowned golf course architect,
More informationyour distributor: powerplastics.com Dealer Price Book 2014-2015 Effective from 01/11/2014 Rivulis Irrigation 3 - EMEA
Dealer Book 2014-2015 Effective from 01/11/2014 3 - EMEA Welcome to the 2014-2015 Dealer Book! Included in the book you will find the general description of the product, key features, packaging quantities,
More informationGetting the job done: Moving your gas supply. Why would I need to alter my gas supply? What to expect. Working on your property
Altering the position of your gas supply Moving your gas supply Northern Gas Networks owns all of the gas pipelines in the North East, most of Yorkshire and northern Cumbria, servicing 2.7 million customers.
More informationGetting the job done: Moving your gas supply. Why would I need to alter my gas supply? What to expect. How we work
ALTERING THE POSITION OF YOUR GAS SUPPLY MULTIPLE PROPERTIES, INDUSTRIAL AND COMMERCIAL Moving your gas supply Northern Gas Networks owns all of the gas pipelines in the North East, most of Yorkshire and
More informationINTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN 78 95. MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER
INTRODUCTION Thank you for purchasing a WATERBOY pumping system. We set the standard for quality and economy in solar pumping. The WATERBOY range incorporates the best solar pump technologies that were
More informationTHE TOWN AND COUNTRY PLANNING ACT 1990 Grant of Planning Permission
Civic Offices Havant Hampshire PO9 2AX Tel (023)9247 4174 Fax(023)9244 6588 DX50005 Havant www.havant.gov.uk To: ADP Architects Ltd Richmond Court 94 Botley Road Park Gate Southampton, Hants SO311BA For:
More informationShower Handbook (Also covers 650 chrome variant)
Shower Handbook (Also covers 650 chrome variant) IMPORTANT: Please retain this booklet for future reference CONTENTS Page How to use your shower 2 How your shower works 3 What to do if things go wrong
More informationPRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems
PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems PACKAGE SEWAGE TREATMENT SYSTEM Clearwater treatment plants are ideal for single houses and employ the well proven aerobic biological
More informationBuilding over or close to a public sewer
Building over or close to a public sewer thameswater.co.uk/developerservices thameswater.co.uk/developerservices 1 Questions and answers Did you know Thames Water is legally responsible for more than 100,000
More informationBureau Veritas Contact Information
Bureau Veritas Contact Information Permit Submittal The permit documents and fees will be submitted to the city. Submittal documents should be complete to expedite plan review and permit issuance. Please
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More informationHow To Manage A Property In Scotland
CASTLETON, ELLON SCOTIA HOMES MANAGEMENT OF COMMON AREAS INFORMATION SHEET Statement of Intent VISION To create and sustain the development at Castleton, Ellon, for the benefit of all. AIMS Scotia will
More informationWhen Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue
When Safety Comes First Emergency Safety Shower and Eye Wash Catalogue No industry, irrespective of its size or its function, can afford to neglect the safety of its personnel and the general public. Advances
More informationHome page Previous Next
n About DALROD n Drain Cleaning & Waste Disposal n CCTV Surveys n Sewer Renovation n Pumping Solutions n Gutter Cleaning Solutions n DALROD s Accreditations n Contact Us As one of the largest independent
More informationFabricated Drainage Products
Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage
More informationCOATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
More informationIMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
More informationA guide to preventing structural damage
A guide to preventing structural damage Home owners guide to planning landscaping and maintenance of foundations Structural damage can result from movement in clay soils caused by varying moisture conditions
More informationCERTIFYING DRAINLAYER
No. 9198 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING DRAINLAYER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced
More informationAPPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE
APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE JURISDICTION OF ALBERTA TRANSPORTATION 1.0 Application Procedures 2.0
More informationElectric Service Conversion Overhead-to-Underground. Minnesota
Electric Service Conversion Overhead-to-Underground Xcel Energy Electric Connections Minnesota Process Please fill out these forms and complete this checklist to begin your application process: 1) Overhead-to-Underground
More informationWAVERLEY BOROUGH COUNCIL ENVIRONMENTAL SERVICES DEPARTMENT WASTE AND RECYCLING
WAVERLEY BOROUGH COUNCIL ENVIRONMENTAL SERVICES DEPARTMENT WASTE AND RECYCLING Requirements for Refuse and Recycling Provision on New Developments Guidance Notes for Applicants and Agents 1. Waste policy
More informationThere are several different products to choose from, depending on the goals, and the type of project being considered.
USGBC and LEED The U.S. Green Building Council (USGBC) is a non-profit organization committed to expanding sustainable building practices. USGBC is composed of 78 local affiliates, more than 18,000 member
More informationResidential Turf Removal Program Application Package
Instructions Residential Turf Removal Program Application Package 1. PROJECTS THAT HAVE BEEN STARTED OR ALREADY COMPLETED PRIOR TO REBATE RESERVATION APPROVAL ARE NOT ELIGIBLE. 2. Read the program terms
More informationPLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.
PLEASE NOTE This document, prepared by the Legislative Counsel Office, is an office consolidation of this regulation, current to August 1, 2013. It is intended for information and reference purposes only.
More informationEnvironmental guidelines for preparation of an Environment Management Plan
Environmental guidelines for preparation of an Environment Management Plan Environment Protection Authority MAY 2013 Australian Capital Territory, Canberra 2013 This work is copyright. Apart from any use
More informationWALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS
1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding with the installation,
More informationSUBSURFACE DRIP IRRIGATION FOR TURF
The following paper is from a source outside Kansas State University. It is provided here for informational purposes only. For more information about this paper or further application of this technology
More informationREAD ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)
CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 17 - NONPOTABLE RAINWATER CATCHMENT SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state
More informationPGA Valve Installation and Operating Instructions Troubleshooting Guide
PGA Valve Installation and Operating Instructions Troubleshooting Guide INSTALLATION & OPERATING INSTRUCTIONS 1. Flush main line thoroughly before installing valves. 2. Install valve onto main line. Ensure
More informationGuidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)
de Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012) Introduction The rules governing permitted development (that is, whether
More informationCivil Engineering and Architecture (CEA) Detailed Outline
Civil Engineering and Architecture (CEA) Detailed Outline Unit 1: Overview of Civil Engineering and Architecture (23 days) Lesson 1.1: History of Civil Engineering and Architecture 1. Many features of
More informationAUSTRALIAN GOVERNMENT BRANDING
AUSTRALIAN GOVERNMENT BRANDING GUIDELINES ON USE OF THE AUSTRALIAN GOVERNMENT LOGO BY AUSTRALIAN GOVERNMENT DEPARTMENTS AND AGENCIES 1. Introduction 1.1 Policy basis 1.2 Further information 2. Elements
More informationThis Specification shall be read in conjunction with the pricing schedule in Schedule 2 of the Tender Conditions and the Design Drawings as follows:
4. SPECIFICATION Contract No: 1772 16 General This Specification shall be read in conjunction with the pricing schedule in Schedule 2 of the Tender Conditions and the Design Drawings as follows: Drawing
More informationPUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE
REGION OF PEEL PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE Storm Sewer Design Criteria REVISED July 2009 PUBLIC WORKS STORM SEWER DESIGN CRITERIA TABLE OF CONTENTS 1.0
More informationIrrigation Efficiency Rewards
Irrigation Efficiency Rewards Options for Agricultural Irrigation Customers Make improvements to your irrigation system and earn a financial incentive from Idaho Power. Irrigation Efficiency Rewards Custom
More informationElectrical Practices for Construction Work
1. Purpose Electrical Practices for Construction Work The purpose of this Code is to provide practical guidance and set minimum safety requirements for electrical practices on all construction sites in
More information4.3 Cisterns and Rain Barrels
4.3 Cisterns and Rain Barrels Rain barrels, cisterns, and tanks are structures designed to intercept and store runoff from rooftops. Rain barrels are used on a small scale while cisterns and tanks may
More informationPollution Control NEW! NEW! Stormwater Attenuation Systems Sustainable Urban Drainage Solutions for Domestic & Commercial Applications. klargester.
Pollution Control NEW! NEW! Stormwater Attenuation Systems Sustainable Urban Drainage Solutions for Domestic & Commercial Applications klargester.com Stormwater Attenuation Systems Sustainable Urban Drainage
More informationPublic Landscape Aids And Protection Of Assets
Territory and Municipal Services Reference Document 4 LANDSCAPE MANAGEMENT AND PROTECTION PLANS (LMPP) Requirements for the Protection of Public Landscape Assets Adjacent to Development Works Issue 2 Revision
More informationResidential Plumbing BCN 1058
Residential Plumbing BCN 1058 CHAPTER 7 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System MICHAEL KNOTEK 74 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System PLUMBING FIXTURES
More informationDOMESTIC WASTEWATER SYSTEMS
Environmental PROTECTION Systems DOMESTIC WASTEWATER SYSTEMS Highest quality sewage treatment systems from the name you can trust Hynds Aerated Wastewater Systems Hynds Lifestyle Systems are an elite range
More informationASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
More informationData Centre Infrastructure Assessment
Data Centre Infrastructure Assessment Prepared for: ACME INC SAMPLE REPORT Attention: Mr DC Manager This report represents a generic sample data centre audit for a generic customer by Focus Group Technologies.
More informationComplete Solutions for On-Site Wastewater Management
Complete Solutions for On-Site Wastewater Management System 1 Collection System 2 Treatment System 3 Disposal State-of-the-Art, Environmentally Conscious Wastewater Solutions for Developers. Delta Environmental
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationIt was my assignment to physically inspect the 8 trees on site near the proposed construction,
July 11, 2013 Tariton Properties 2555 Park Blvd Palo Alto, CA 94306 Re: Tree Survey To Whom It May Concern: Assignment It was my assignment to physically inspect the 8 trees on site near the proposed construction,
More informationTG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION
TG 105 SOUTH AUSTRALIAN WATER CORPORATION TECHNICAL GUIDELINE ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS Issued by: Manager Asset Management Issue Date: SA WATER 2007 This document is copyright
More informationRETICULATED RECYCLED WATER SCHEMES OPERATIONAL CONSIDERATIONS. Duncan Wallis. RM Consulting Group
RETICULATED RECYCLED WATER SCHEMES OPERATIONAL CONSIDERATIONS Paper Presented by: Duncan Wallis Author: Duncan Wallis, Senior Consultant, RM Consulting Group 72 nd Annual Water Industry Engineers and Operators
More informationHow To Preserve Trees
San Diego County Water Authority Vic Bianes, PE - Engineering Manager Tad Brierton, SR/WA - Right of Way Supervisor APWA National Congress 2013 Chicago, IL 2 1 Background - San Diego County Water Authority
More information