1 Integration Note Manufacturer: Hunter Industries Model Number(s): SRC, SRC Plus, Pro-C, ICC, XCORE, icore Minimum Core Module Version: Document Revision Date: 5/13/2013 OVERVIEW AND SUPPORTED FEATURES Installing a Hunter irrigation controller can be broken down into the following steps: 1. Work with the client and the irrigation contractor to determine which Hunter controller to use, and how to organize the Zone Groups. See Suggested Design Procedure below. 2. Install and connect the SerialBrick Irrigation electrically to the Hunter controller. See Installation Overview for the list of steps required. IMPORTANT NOTE for icore: The icore Irrigation System requires that you use REV C of the Serial Brick for Irrigation in order to function. 3. Integrate the irrigation system into the g! system and test proper operation. This step is outlined in g! Configuration Details. HUNTER IRRIGATION SYSTEMS SUPPORT THE FOLLOWING FEATURES: Familiar Product: The Hunter controllers are familiar to the industry, and can be well understood by all irrigation contractors. Manual Control: Hunter controllers can be easily run in manual mode right at the controller to test operation, check for broken or clogged heads, and perform other standard maintenance, without requiring access to the g! system. Rain Sensor: All supported Hunter controllers allow the connection of a rain sensor to prevent watering when not needed. The g! system detects the status of the rain sensor and displays it in the history view (version 4 and later). Devices Supported: The XCORE, icore, SRC, Pro-C and ICC lines of controllers support a wide variety of residential, light commercial and commercial installations. Anywhere from 3 to 48 zones are supported, with various plastic and stainless steel enclosure options. Refer to the table in Suggested Design Procedure for details of the Hunter lines: refer to the Hunter Web site for more details ( Any feature not specifically noted as supported is not supported. IMPORTANT NOTES WHEN WORKING WITH THE HUNTER CONTROLLER: The icore Irrigation System requires that you use REV C of the Serial Brick for Irrigation in order to function. The SerialBrick-Irrigation must be installed in close proximity to the irrigation controller. The g! system communicates with the Hunter controllers using the Hunter SmartPort, which is a oneway communication link. As a result, any schedule information on the controller cannot be read by the g! system. ELAN Home Systems 1690 Corporate Circle Petaluma, CA USA tech support: main: sales: [email protected] 2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners.
2 The Hunter irrigation controller should be left in the OFF position for day-to-day operation by the g! system. With the controller in the OFF position, the g! system will be able to turn on and off any zone, as well as detect the state of the rain sensor. Manual operation of any zone directly from the irrigation controller is available at any time, as with any standard Hunter installation. Return the controller to the OFF position when finished. SUGGESTED DESIGN PROCEDURE STEP 1: DETERMINE AN APPROPRIATE PANEL Model Stations (Zones) Comments XCORE/iCore 2, 4, 6, or 8 Plastic Indoor or Outdoor SRC Plus 6 or 9 Plastic, Indoor, Wall Mount Pro-C 3, 6, 9, 12 or 15 Plastic, Indoor or Outdoor, Wall Mount ICC (Plastic) 8 to 32 Plastic, Indoor or Outdoor, Wall Mount ICC (Plastic Pedestal, or Metal) 8 to 48 Plastic (Pedestal) or Metal (Wall Mount or Pedestal), Indoor or Outdoor The irrigation contractor will typically work with the client to determine how many zones are needed, and where the zones will be placed. During this planning process, work with the client and the irrigation contractor to assist in the selection of a controller that will satisfy their requirements and also tie into the g! system. Refer to the table above and the details available on the Hunter Web site. STEP 2: ORGANIZE THE ZONES INTO GROUPS Before configuring the g! system, you should work with the client (with input from the irrigation contractor or landscaper) to put the zones into groups: one group for each primary plant type or area. Typical Zone Groups include: Lawn: these zones cover grass areas and are typically watered every few days for a relatively long time to promote deep root growth. Flower Beds: these are zones in a garden that may be watered every day for a relatively short period of time. Organizing the zones into Zone Groups is important because the g! Viewer interface displays and manages the irrigation scheduling by Zone Groups. As an example, the user selects the days to water for each Zone Group, not for each zone. INSTALLATION OVERVIEW The following steps are needed for installation. Refer to the diagrams that follow for various wiring scenarios. 1. During the rough-in phase, run a Cat5 cable from the irrigation controller location to the g! system. Page 2 of 10
3 2. The SerialBrick Irrigation must be installed in close proximity to the irrigation controller location in a weather proof environment. You may wish to install a single-gang outlet adjacent to the controller to cleanly terminate the Cat5 to an RJ45 Female connector. NOTE: The icore Irrigation System requires that you use REV C of the Serial Brick for Irrigation in order to function. 3. Install the irrigation controller and test that all zones function normally in manual mode. 4. Install the SerialBrick Irrigation adjacent to the irrigation controller. 5. Electrically connect the SerialBrick Irrigation to the Hunter SmartPort and to the Ethernet network. Page 3 of 10
4 CONNECTION DIAGRAM The diagram below shows an overview of a typical system. Refer to the Bill of Materials for additional detail, including specific part numbers. 4 Rain Sensor Cable provided with Network Assy. 3 18AWG Control Wire 8 Cat5 Cable Assy. 5 Irrigation Controller Any Ethernet LAN Port 9 Network Assembly See Wiring Diagrams for Details 10 g! System Controller 6 18AWG Control Wire Smart Port ETHERNET 2 Valve 3 18AWG Control Wire 1 Sprinkler 7 SerialBrick - Irrigation BILL OF MATERIALS # Device M anufacturer Part Number Protocol Connector Type Notes 1 Sprinkler Various N/A N/A N/A 2 Valve Various N/A 24VAC Pigtail 3 18AWG Control Wire Various N/A 24VAC Pigtail 4 Rain Sensor Hunter M ini-clik Various Pigtail 5 Irrigation Controller Hunter SRC, SRC Plus, Pro-C, ICC, XCORE 24VAC X SmartPort Terminal Strip 6 18AWG Control Wire Installer N/A SmartPort Pigtail 7 SerialBrick - Irrigation ELAN HW-EB-101 SmartPort X IP Terminal Strip X RJ-45 Female REV C Required for icore 8 Cat5 Cable Assy. Installer N/A IP RJ-45 M ale X RJ-45 M ale 9 Network Assembly or Switch/Router ELAN/Installer NWA18/Various IP RJ-45 Female X RJ-45 Female Use any available LAN port 10 g! System Controller ELAN Various (e.g. HC12) IP RJ-45 Female Note: The EdgeBrick is typically placed in close proximity to the Hunter panel (within 10 feet), and the length of the run placed on the Ethernet side of the EdgeBrick. Page 4 of 10
5 WIRING DIAGRAM 1: HUNTER SRC, SRC PLUS SerialBrick - Irrigation SRC SRC (Plus) Power Supply To Valves Rain Sensor Note: If no rain sensor is being used, short the rain sensor pins instead to simulate a no rain state. Failing to either attach a rain sensor or short the pins will prevent g! from controlling the Hunter panel. IMPORTANT NOTE FOR RAIN SENSOR: The Hunter documentation instructs you to connect the common from the valves to the RS terminal, while we show the common going to the C terminal above. To enable manual control from the g! Viewer when the rain sensor is open, you must wire the common to the C terminal as shown. Page 5 of 10
6 WIRING DIAGRAM 2: HUNTER PRO-C Rain Sensor SerialBrick - Irrigation SEN SEN REM AC2 AC1 GND Power Supply Pro-C P/MV COM To Valves Note: The TOP rain sensor terminal of the Pro-C goes to the RS terminal on the SerialBrick - Irrigation. Important Note: If no rain sensor is being used, short the rain sensor pins instead to simulate a no rain state. Failing to either attach a rain sensor or short the pins will prevent g! from controlling the Hunter panel. Page 6 of 10
7 WIRING DIAGRAM 3: HUNTER ICC Note: The TOP rain sensor terminal of the ICC goes to the RS terminal on the SerialBrick - Irrigation. Important Note: If no rain sensor is being used, short the rain sensor pins instead to simulate a no rain state. Failing to either attach a rain sensor or short the pins will prevent g! from controlling the Hunter panel. Page 7 of 10
8 WIRING DIAGRAM 4: HUNTER XCORE Note: The XCORE may support more advanced sensors, such as solar sensors, but these have not been evaluated with g! and are not expected to function. SerialBrick - Irrigation Rain Sensor AC AC REM SEN SEN C Note: if not using Rain Sensor short SEN terminals instead To Valves Power Supply XCORE Note: The LEFT SEN terminal of the XCORE goes to the RS terminal on the SerialBrick - Irrigation. Important Note: If no rain sensor is being used, short the rain sensor pins instead to simulate a no rain state. Failing to either attach a rain sensor or short the pins will prevent g! from controlling the Hunter panel. Page 8 of 10
9 g! CONFIGURATION DETAILS The following table provides settings used in the g! Configurator when connecting to a Hunter irrigation controller. Please refer to the Configurator Reference Guide for more details. In the table below: o <Select> Select the appropriate item from the list (or drop-down) in the Configurator. o <User Defined>, etc. Type in the desired name for the item. o <Auto Detect>, etc. The system will auto detect this variable. Devices Variable Name Setting Comments Communication Devices Name <Auto Detect> (Default: Hunter ) (See Note 1) Type (IP to Serial) SerialBrick Select Brick <Select> Communication Type Standard Connection Location <User Defined> (Not Required) Irrigation Controller Name <User Defined> (Default: Hunter SRC, Pro-C, ICC) Device Type Hunter SRC, Pro-C, ICC Location <User Defined> (Not Required) COM Device <Auto Detect> (Default: Hunter ) (See Note 1) Irrigation Zone Groups Name <User Defined> You must add at least one zone group. Irrigation Zones Controller <Auto Detect> Zone Number <User Defined> (Default: 1) This is the Hunter station number or terminal number Group <Select> Zone Name <User Defined> (Default: New Zone) Irrigation Periods Period Name <User Defined> (Default: New Period) (See Note 2) Add one period for each desired start time. Notes: 1. The g! system reads the name from the SerialBrick. The name by default is Hunter: , where the will show the actual serial number. 2. There is one period (Morning) by default. Add one period for each addition start time desired, such as Noon, and Evening. Page 9 of 10
10 COMMON MISTAKES 1. Wiring the AC1 and AC2 terminals on the SerialBrick Irrigation backwards. Check the wiring diagram for your model of controller. 2. On the SRC or SRC Plus, failing to wire the rain sensor according to the diagram show in this Integration Note. If you follow the instructions provided in the Hunter documentation then you will not be able to manually turn on a zone from the g! system (to check the spray pattern, for example) when the rain sensor is open. 3. On the Pro-C and ICC, wiring the rain sensor to the wrong SEN terminal. Check the wiring diagram for your model of controller. 4. If the Hunter panel is showing Err in its display then the wiring length between the SerialBrick and the Hunter panel may be too long. In this case relocate the SerialBrick closer to the Hunter panel. 5. Not using REV C of the irrigation brick with the icore Panel Page 10 of 10
Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.
Manufacturer: Model Number(s): Minimum Core Module Version: Comments: HAI Document Revision Date: 4/18/2013 OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY Firmware V. 1.03 Tested Integration Note OVERVIEW
Minimum Core Module Version: Comments: Server Version: IP Video V2.38 & V2.39 Document Revision Date: 2/13/2013
Integration Note Manufacturer: AVIOSYS Model Number(s): IP Video 9100B Minimum Core Module Version: Comments: Server Version: IP Video V2.38 & V2.39 Document Revision Date: 2/13/2013 OVERVIEW AND SUPPORTED
Export: Exporting the call log or Voice Mail messages from the Viewer software is not supported.
Integration Note Manufacturer: ELAN Home Systems Model Number(s): GMOD Minimum Core Module Version: Comments: Document Revision Date: 03/25/2015 OVERVIEW AND SUPPORTED FEATURES Note: While the g! system
RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! 6.4.200 RadioRA2 Inclusive Software v5.0.8 or newer
Manufacturer: Model Number(s): Minimum Core Module Version: Comments: Lutron Document Revision Date: 8/5/2013 OVERVIEW AND SUPPORTED FEATURES Integration Note RadioRA 2 (QS) Lighting and Climate Control
Baldwin, Kwikset, Schlage, Yale. 5.7 or newer required
Manufacturer: Model Number(s): Core Module Version: Document Revision Date: 4/14/2014 OVERVIEW AND SUPPORTED FEATURES Baldwin, Kwikset, Schlage, Yale Integration Note Baldwin 8252.112.AC3, 8252.112.AC3X,
ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions
ETHERNET IRRIGATION CONTROLLER Irrigation Caddy Model: ICEthS1 User Manual and Installation Instructions I R R I G A T I O N C A D D Y M O D E L : I C E T H S 1 User Manual and Installation Instructions
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
with SmartPort Connection Connection with SmartPort
Residential/Light Residential/Light Commercial Commercial Remote Control Remote System Control System Owner s Manual Owner s and Manual and Installation Installation Instructions Instructions For use with
ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
SRP. Controller Programming System for Commercial and Residential Irrigation Controllers. Owner s Manual and Installation Instructions
SRP Controller Programming System for Commercial and Residential Irrigation Controllers Owner s Manual and Installation Instructions SRP Programming Software The disk supplied with this kit contains the
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
Proving that extra smart can also be extra simple.
ESP-SMTe Smart Control System Proving that extra smart can also be extra simple. Smart Technology has reached its tipping point. Other smart controllers claim simplicity and precision; the Rain Bird ESP-SMTe
SHDSL LAN EXTENDER H301A. User Manual
SHDSL LAN EXTENDER H301A User Manual Rev. 1.0 Yoda Communications, Inc. Yoda Communications, Inc. Address 2F, No. 3-1, Industry East Road IX, Science Based Industrial Park, HsinChu, Taiwan Tel 886-3-5632323
Chapter 2 System Basics
Chapter 2 System Basics The Evolution DX2 Controller contains a comprehensive feature set to support virtually any conceivable irrigation system/configuration. In addition to the more traditional irrigation
SRC. Residential/Light Commercial Irrigation Controller. 600i 6-station Indoor Model 601i 6-station Indoor Model (International)
SRC Residential/Light Commercial Irrigation Controller Owner s Manual and Programming Instructions 600i 6-station Indoor Model 601i 6-station Indoor Model (International) 900i 9-station Indoor Model 901i
Residential Irrigation Controller NEW. Owner s Manual and Programming Instructions Compatible with Hunter Remotes and Solar Sync RUN
SYSTEM OFF CURRENT TIME/DAY MANUAL-ONE STATION START TIMES SEASONAL ADJUSTMENT WATER DAYS Residential Irrigation Controller RUN SENSOR BYPASS ACTIVE RUN TIMES NEW Owner s Manual and Programming Instructions
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM
ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic
Security & Surveillance Cabling Systems
Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.
Long Range Ethernet Extender
Long Range Ethernet Extender Model Number: EIDM-EXTEND-2 User s Manual Rev. 1.0 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone: (815) 433-5100 General
Chapter 1 Connecting the Router to the Internet
Chapter 1 Connecting the Router to the Internet This chapter describes how to set up the router on your Local Area Network (LAN) and connect to the Internet. It describes how to set up your wireless ADSL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
User s Guide. Sprinkler Timer with Computer Programming Option. ECXTRA Features
User s Guide Sprinkler Timer with Computer Programming Option ECXTRA Features OUTDOOR MODEL A B C ON MANUAL NEXT START OFF ON MANUAL START OFF INDOOR MODEL NEXT Easily expandable to 10 Zones (Indoor model)
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
2-Pair. Managed SHDSL Ethernet Extender. User s Manual
2-Pair User s Manual 1. Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender. This is the Ethernet Extender of choice to extend 10/100 Ethernet
WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
OC810 Outdoor Camera Setup Guide
OC810 Outdoor Camera Setup Guide P/N: 957YU60001 Document Version: 1.0 Copyright 2010. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package Contents
Alliance System Ordering Guide
Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
OC810 Outdoor Camera Installation Guide
OC810 Outdoor Camera Installation Guide P/N: 957YU601GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owner i Package
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO. Central Control System
ROTORS MP ROTATOR SPRAYS VALVES CONTROLLERS SENSORS CENTRAL CONTROLS MICRO IMMS 3.0 Central Control System Open the Window to Your World Hunter s Irrigation Management & Monitoring Software (IMMS) is a
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
Hardware Installation Guide HotPoint 5100 Access Point
HotPoint Hardware Installation Guide HotPoint 5100 Access Point Published March 2014 (Revised 2015) 2014 Firetide, Inc. All rights reserved. Firetide, the Firetide logo, Reliable connectivity anywhere,
SRC Plus. Residential/Light Commercial Irrigation Controller. 600i 6-station Indoor Model 601i 6-station Indoor Model (International)
SRC Plus Residential/Light Commercial Irrigation Controller Owner s Manual and Programming Instructions Plus 600i 6-station Indoor Model 601i 6-station Indoor Model (International) 900i 9-station Indoor
HomeWorks QS Processor
product specifications 369-376 The processor provides control and communication to system components. The Ethernet links allow communication to the software, integration with third party systems and communication
Solar monitoring gateway quick start guide
Instructional Leaflet I70002E LGATE101-1B LGATE101-1A LGATE101-5B LGATE101-5A Contents Description Page General................................. 2 Information collection sheet............... 2 Quick reference
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
MultiVOIP FX SIP Gateways
MultiVOIP FX SIP Gateways MVPFX2-2 MVPFX2-4 MVPFX2-8 Cabling Guide Cabling Guide MultiVOIP FX SIP Gateways, Models MVPFX2-2, MVPFX2-4, MVPFX2-8 82100090L Rev. A Copyright This publication may not be reproduced,
RC8021 Indoor Camera Installation Guide
RC8021 Indoor Camera Installation Guide P/N: 957YL502GJ Document Version: 1.0 Copyright 2011. All Rights Reserved. All trademarks and trade names are the properties of their respective owners i Package
Reference Design. conference rooms
Reference Design conference rooms Tomaro Design Group conference rooms The modern commercial conference room embraces communication and multi-media technology from projectors and video conferencing, to
Cisco Aironet Wireless Bridges FAQ
Cisco Aironet Wireless Bridges FAQ Document ID: 16041 Contents Introduction What is the Cisco Aironet Wireless Bridge? What are the different platforms of wireless bridges that Cisco offers? Where can
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7
Contents Chapter 1: Introduction... 3 Communication Types and Functionality... 3 Communication Connectors... 3 Communication Lightning Protection... 4 Chapter 2: Ethernet (LAN)... 5 Single/Multiple Devices,
BASLER ACE QUICK INSTALLATION GUIDE
BASLER ACE QUICK INSTALLATION GUIDE Rev. 01 Quick installation Guide V1 1 Introduction The installation procedures in this guide assume that you want to get your camera operational and begin capturing
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
Table of Contents. Chapter1. Introduction...1. 1.1 Before Installation... 1 1.2 System Requirements... 1
Table of Contents Chapter1. Introduction...1 1.1 Before Installation... 1 1.2 System Requirements... 1 Chapter2. IVS-110 1-Channel Internet Video Server...2 2.1 Package Content... 2 2.2 Physical Installation...
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide
Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch IGS-5225 Series Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5 4. Terminal
MultiVOIP FX FXS-Only SIP Gateways
MultiVOIP FX FXS-Only SIP Gateways MVPFXS-8 MVPFXS-16 MVPFXS-24 Cabling Guide MultiVOIP MVPFXS-8/16/24 Cabling Guide Cabling Guide MultiVOIP FX SIP FXS-Only Gateways Models MVPFXS-8, MVPFXS-16, MVPFXS-24
Connecting the DG-102S VoIP Gateway to your network
Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
Signature Center Getting Started Guide
Signature Center Getting Started Guide 1113710 PRODUCED IN IRELAND Copyright 2010 McKesson Corporation and/or one of its subsidiaries. All Rights Reserved. This documentation is an unpublished work of
ETHERNET WEATHER STATION CONNECTIONS Application Note 33
ETHERNET WEATHER STATION CONNECTIONS Application Note 33 With WeatherLink and a Device Server INTRODUCTION It is possible to substitute an Ethernet connection for the direct USB or serial connection that
User s Guide. Automatic Sprinkler System Control Timer. ECXTRA Features
Automatic Sprinkler System Control Timer User s Guide ECXTRA Features OUTDOOR MODEL A B C ON MANUAL NEXT START OFF ON MANUAL START OFF INDOOR MODEL NEXT Easily expandable to 10 Zones (Indoor model) or
INTRODUCTION FEATURES OF THE ICM
INTRODUCTION The ICM, Internet Control Module, is a remote controller device accessible via the Internet that allows operational access to the IPS (and other base units available). Through the ICM you
QSE-CI-NWK-E Control Interface
QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
NeoGate TA Series Installation Guide
NeoGate TA Series Installation Guide Version 1.2 Date: April 1, 2015 Yeastar Information Technology Co. Ltd Contents 1. Preparation before Installation... 3 2. Hardware Specifications... 5 2.1 Overview...
HARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
300Mbps Wireless-N Access Point/Repeater
300Mbps Wireless-N Access Point/Repeater WFREPEAT300N *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario -
ACC-COM-LAN Communications Module (for Ethernet connections)
ACC-COM-LAN Communications Module (for Ethernet connections) NEW ACC-COM-LAN Communications Module (for Ethernet connections) Owner s Manual & Installation Instructions A Table of Contents introduction..............................................
Quick Installation Guide DVG-N5402SP VoIP Router
Quick Installation Guide DVG-N5402SP VoIP Router Check Your Package Contents DVG-N5402SP VoIP Router Ether (CAT5 UTP) Cable 12VDC, 2A Power Adapter Using a power adapter with a different voltage rating
CANOPY TM AP C A N O P Y C A N O P Y. Getting Started with Motorola REV 12/18/01. Specifications
Specifications Operating Frequency Range U-NII Mid band 5.25 to 5.35 GHz Access Method TDD/TDMA Data Rate 10 Mbps Modulation Type High Index BFSK/4FSK (Optimized for interference rejection) Carrier to
Ensto Chago Master EVM300 and EVM500 Operational description
Pages: 1 (8) Ensto Chago Master EVM300 and EVM500 Operational Pages: 2 (8) Contents 1 What is Ensto EVM... 3 2 EVM versions... 3 2.1 EVM300... 4 2.2 EVM500... 5 3 Technical information... 7 Pages: 3 (8)
Wi-Fi & Home Automation Module. Installation and User Manual
Wi-Fi & Home Automation Module Installation and User Manual Table of contents Section Description Page No. 1.0 Installation 3 1.1 Standard wiring layout for Wi-Fi control 3 1.2 Standard wiring layout for
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.
Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION
GE Lighting Installation Instructions Lighting Controls Centralized Lighting Control Panel Interior Catalog Number CLCINTxx DESCRIPTION The Centralized Lighting Control System is a small network of relay
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
IP Indoor High Speed Dome. CAM-6500 series. Ver. 070307. Quick Installation Guide
IP Indoor High Speed Dome CAM-6500 series Ver. 070307 Quick Installation Guide 1 1 Getting Started 1.1 PACKAGE CONTENTS CAM-6500 series Warranty Card Software CD Power & A/V Cable LAN/WAN Cable Alarm Cable
FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223
FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Climate Ready Control Systems Technical Specifications
Climate Ready Control Systems Technical Specifications Climate Ready Control Systems Climate Ready Control Systems consist collectively of motor controllers, other hardware and software packages that will
1 Port RS232 Serial over IP Device Server
1 Port RS232 Serial over IP Device Server NETRS232 *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
Logitech Alert Video Security System. Getting To Know
Logitech Alert Video Security System Contents Introduction................................................................ 3 Live Mode Viewing..........................................................
Installation Guide Solar Connect-11
Installation Guide Solar Connect-11 Version 1.1 Contents Important Product Information 3 System Registration Form 4 Solar Connect-11 Overview 5 Internet & Power Connections 6 Single Phase CT Connections
MAX-306M1 Series. WiMAX MIMO Outdoor Simple CPE DEFAULT LOGIN DETAILS. Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz)
MAX-306M1 Series Models: MAX-306M1 (2.5 GHz) and MAX-316M1 (3.5 GHz) WiMAX MIMO Outdoor Simple CPE Firmware v3.70 Edition 2, 12/2009 DEFAULT LOGIN DETAILS IP Address: Username: http://192.168.1.1 admin
Application Note. Terminal Server G6
MICROSENS GmbH & Co. KG Küferstr. 16 59067 Hamm/Germany Tel. +49 2381 9452-0 FAX +49 2381 9452-100 E-Mail [email protected] Web www.microsens.de Summary As of firmware version v10.6 MICROSENS Generation
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
MultiModem ZBA. Quick Start Guide. MT9234ZBA-Series MT9234ZBA MT9234ZBA-V
MultiModem ZBA MT9234ZBA-Series MT9234ZBA MT9234ZBA-V Quick Start Guide MultiModem ZBA Quick Start Guide MT9234ZBA & MT9234ZBA-V 82100201L Rev. B Copyright This publication may not be reproduced, in whole
Spectralink IP-DECT Server 400 Base Units
Spectralink IP-DECT Server 400 Base Units Planning and Installation Guide When Ordering Handsets and Base Units Note: 8x8 recommends you plan your installation before ordering handsets and base units.
AC1200 WiFi Range Extender
Model EX6200 User Manual February 2014 202-11298-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number
[USING THE NM150 WITH ADULTICIDING] July 13, 2015
Reason Adulticiding 3.5 includes support for the New Mountain NM150 Weather Station. Adulticiding fogger log point details include temperature, wind speed, and wind direction. These can be recorded from
HSG Engineering Tech Bulletin
Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for
CONNECTING PHONES, FAXS & DEVICES TO TALKSWITCH
TALKSWITCH QUICK GUIDE CONNECTING PHONES, FAXS & DEVICES TO TALKSWITCH CONNECTING PHONES, FAXES & DEVICES TO TALKSWITCH CT.TS005.504.EN - 03 TalkSwitch Back Panel TalkSwitch 48-CA/ 48-CVA shown here. Model
Installation & Operations Manual
Installation & Operations Manual VoIP Command Center Made in the USA 3 Year Warranty N56 W24720 N. Corporate Circle Sussex, WI 53089 800-451-1460 262-246-4828 (fax) www.rathmicrotech.com www.area-of-refuge.com
HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL)
DATA SHEET HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL) Overview With space for up to 12 modules, the HPX-1200 allows you to
Short Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
The Consumer Electronics Association TechHome Rating System Guidelines
The Consumer Electronics Association TechHome Rating System Guidelines The TechHome Rating System (THRS) is a powerful new nationally-recognized build-to specification for residential technology infrastructure.
IntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)