Molded Case Circuit Breakers
|
|
- Gladys Bradley
- 7 years ago
- Views:
Transcription
1 Panelboard Mounting with INSTA-WIRE 1-Pole Bolt-On (120V AC) e Bolt-On (Common-Trip 120/240V AC) f 10 B B215 B215H B215HH 20 B220 B220H B220HH 25 B225 B225Hn B225HHn 30 B230 B230H B230HH 35 B235 B235Hn B235HHn 40 B240 B240H B240HH 45 B245 B245Hn B245HHn 50 B250 B250H B250HH 60 B260 B260H B260HH 0 B20 B20Hn B20HHn 80 B280 B280Hn B280HHn 90 B290 B290Hn B290HHn 100 B2100 B2100H B2100HH 110 B2110n B2110Hn B2110HHn 125 B2125 B2125H B2125HHn Bolt-On (Common-Trip 240V AC) cf 15 B215R 20 B220R 30 B230R 40 B240Rn 50 B250R 60 B260R 0 B20Rn 80 B280Rn 90 B290Rn 100 B2100Rn 3-Pole Bolt-On (Common-Trip 240V AC) g Type BL a Type BLH Type HBL 10,000A IR 22,000A IR 65,000A 40 C 10 B B115 d B115H d B115HH d 20 B120 d B120H d B120HH d 25 B125 B125H B125HHn 30 B130 B130H B130HH 35 B135 B135Hn B135HHn 40 B140 B140H B140HH 45 B145n B145Hn B145HHn 50 B150 B150H B150HHn 60 B160 B160Hn B160HHn 0 B10 B10Hn B10HHn 15 B315 B315H B315HH 20 B320 B320H B320HH 25 B325 B325H B325HHn 30 B330 B330H B330HH 35 B335 B335Hn B335HHn 40 B340 B340H B340HH 45 B345 B345Hn B345HHn 50 B350 B350H B350HH 60 B360 B360H B360HH 0 B30 B30H B30HH 80 B380 B380Hn B380HH 90 B390 B390Hn B390HH 100 B3100 B3100H B3100HH 03/06/13 1-Pole 3-Pole Breaker Dimensions Type Amperes L D1 D2 BL, BLH BL, BLH HBL BL/BLH/HBL Internal Accessories Description Field/Factory Installed 120V Shunt Trip add suffix...00s01n Factory 24V Shunt Trip add suffix...00s0n Factory 120V Auxiliary Switch add suffix...01n b Factory Modifications Description 400Hz Calibration Marine 50 C Ambient Calibration Fungus Proofing add suffix...y h add suffix...m add suffix...f For external accessories, please refer to page -93 n Built to order. Allow 2-3 weeks for delivery a UL Listed for use with 60/5 wire through 40 amps, UL listed for use with 5 wire only for 50 amps and above, HACR rated. 120V AC Fluorescent Lighting. b 1A and 1B contacts. c UL Listed for use on 3-phase grounded B systems 10,000 for this application. d UL Listed for frequent switching applications (SWD). e Shipped 12 per sleeve. f Shipped 6 per sleeve. g Shipped 4 per sleeve. h UL Listed 5KA IR. i 10 Amp breaker does not have INSTA-WIRE. jfor 3 Phase Applications. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -29
2 Panelboard Mounting Circuit Breakers Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arc-fault is detected. Combination Type AFCI Detects all three possible types of arc fault: line-to-ground, line-to-neutral, and series. Breaker Type BAF/BAFH 1-Pole 120V AC BAF/BAFH 120/240V AC Ampere 10,000 A IR 22,000 A IR Rating 15 B115AFC a B115AFCHn 20 B120AFC a B120AFCHn 15 B215AFC a B215AFCHn 20 B220AFC a B220AFCHn 1-Pole Combination Type AFCI 08/02/13 Combination Type AFCI Branch-Feeder AFCI Detects line-to-ground and line-to neutral arcs. BAF/BAFH 1-Pole 120V AC B115AF a B120AF a B115AFHn a B120AFHn a Ground-Fault Circuit Interrupters (GFCI) Provides Class A (5mA) ground fault protection. Intended for personnel protection. De-energizes the circuit for all ungrounded conductors of the circuit. BLF/BLHF 1-Pole 120V AC Bolt-On BLF/BLHF 120/240V AC Bolt-On 15 BF115 a BF115H a 20 BF120 a BF120H a n 25 BF125 n BF125H n 30 BF130 BF130H 15 BF215 BF215H 20 BF220 BF220H 30 BF230 BF230H 40 BF240 BF240H 50 BF250 BF250H 60 BF260 BF260H Ground Fault Equipment Protection (30mA) Provides protection of equipment from damaging line-to-ground faults currents. De-energizes the circuit for all ungrounded conductors of the circuit. BLE/BLEH 1-Pole, 120V AC Bolt-On BLE/BLEH 120/240V AC Bolt-On QAF/QPF/QE Accessories Description Padlocking Device 1-Pole Padlocking Device Handle Block BE115 a BE120 a BE130 BE215 BE220 BE230 BE240 BE250 BE260n ECPLD1 ECPLD2 ECBX231M BE115H a BE120H a BE130H BE215H BE220H BE230H BE240H BE250H BE260Hn Wiring Diagrams 1-Pole Equipment Protection 1-Pole Branch Feeder AFCI Equipment Protection n Built to order. Allow 2 3 weeks for delivery. a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. -30 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog
3 Panelboard Mounting Circuit Breakers Special Application Breakers Switching Neutrals a Breaker Type BG 2-Wire Common Trip BG 3-Wire Common Trip HID Lighting a Ampere Rating 15 BG215 n 20 BG220 n 30 BG230 n 15 BG315 n 20 BG320 n 30 BG330 n For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. BL 1-Pole BL 15 B115HID b n 20 B120HID b 30 B130HID n 15 B215HID b n 20 B220HID b 30 B230HID n Switching Neutrals Tungsten Lighting For high wattage, tungsten-lamp loads in-rush currents above the instantaneous trip setting of a standard breaker. BL 1-Pole 15 B115T b 20 B120T b Molded Case Switch For applications that do not require overcurrent protection. BL 30 B230S 60 B260S n Built to order. Allow 2 3 weeks for delivery. a HACR rated. b UL Listed for frequent switching applications (SWD). 120V AC fluorescent lighting. Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -31
4 BQD 100A Frame Panelboard Mounting Circuit Breakers BQD d 1-Pole c 3-Pole c Current 2V AC 125V DC 480Y/2V AC 125/250V DC 480Y/2V AC 40 C 15 BQD115 a b BQD215 e BQD315 e 20 BQD120 a b BQD220 e BQD320 e 25 BQD125 b BQD225 e BQD325 e 30 BQD130 b BQD230 e BQD330 e 35 BQD135 b BQD235 e BQD335 e 40 BQD140 b BQD240 e BQD340 e 45 BQD145 b n BQD245 e BQD345 e 50 BQD150 b BQD250 e BQD350 e 60 BQD160 BQD260 BQD360 0 BQD10n BQD20 BQD30 80 BQD180n BQD280 BQD BQD190n BQD290 BQD BQD1100n BQD2100 BQD3100 BQD6 CSA Certified Current 40 C 1-Pole c 3-Pole c 34V AC 600/34V AC 600/34V AC 15 BQD6115 a BQD6215 BQD BQD6120 a BQD6220 BQD BQD6125n BQD6225n BQD6325n 30 BQD6130 BQD6230 BQD BQD6135n BQD6235n BQD6335n 40 BQD6140n BQD6240n BQD BQD6145n BQD6245n BQD6345n 50 BQD6150n BQD6250n BQD BQD6160n BQD6260n BQD BQD610n BQD620n BQD630 Shipping Weights /Dimensions BQD, BQD6 BQD, BQD6 Number of Number per Shipping Poles Carton Weight (lbs.) (ea.) 1 1/12/ /6/ /4/ Interrupting Ratings RMS Symmetrical Amperes (KA) Number Volts AC Volts DC Breaker of 480/ 600/ 125/ Type Poles BQD (UL) BQD (CSA) Lugs For 60/5 C Wire BQD Load End Only #14 #6 AWG Cu #12 #6 AWG Al #8 #1 AWG Cu #6 #1/0 AWG Al For inches / millimeters conversion, see Application Data section. n Built to order. Allow 2 3 weeks for delivery. aswd rated for switching fluorescent lighting. bhid rated at 2V AC. cnot suitable for 3-phase delta 480V applications. d HACR rated. ehid rated at 480Y/2V AC. For external accessories, please refer to pages -95 to -100 For internal accessories, please refer to page Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog
5 GB Frame Type NGB Frame (Panelboard 40 C 15 NGB1B015B a b NGB2B015B b NGB3B015B b 20 NGB1B020B a b NGB2B020B b NGB3B020B b 25 NGB1B025B b NGB2B025B b NGB3B025B b 30 NGB1B030B b NGB2B030B b NGB3B030B b 35 NGB1B035B b NGB2B035B b NGB3B035B b 40 NGB1B040B b NGB2B040B b NGB3B040B b 45 NGB1B045B b NGB2B045B b NGB3B045B b 50 NGB1B050B b NGB2B050B b NGB3B050B b 60 NGB1B060B NGB2B060B NGB3B060B 0 NGB1B00B NGB2B00B NGB3B00B 80 NGB1B080B NGB2B080B NGB3B080B 90 NGB1B090B NGB2B090B NGB3B090B 100 NGB1B100B NGB2B100B NGB3B100B 110 NGB1B110B NGB2B110B NGB3B110B 125 NGB1B125B NGB2B125B NGB3B125B Load lugs are included as standard. HACR rated. Type HGB (Panelboard 40 C 15 HGB1B015B a b HGB2B015B b HGB3B015B b 20 HGB1B020B a b HGB2B020B b HGB3B020B b 25 HGB1B025B b HGB2B025B b HGB3B025B b 30 HGB1B030B b HGB2B030B b HGB3B030B b 35 HGB1B035B b HGB2B035B b HGB3B035B b 40 HGB1B040B b HGB2B040B b HGB3B040B b 45 HGB1B045B b HGB2B045B b HGB3B045B b 50 HGB1B050B b HGB2B050B b HGB3B050B b 60 HGB1B060B HGB2B060B HGB3B060B 0 HGB1B00B HGB2B00B HGB3B00B 80 HGB1B080B HGB2B080B HGB3B080B 90 HGB1B090B HGB2B090B HGB3B090B 100 HGB1B100B HGB2B100B HGB3B100B 110 HGB1B110B HGB2B110B HGB3B110B 125 HGB1B125B HGB2B125B HGB3B125B Shipping Weights Number of Number per Shipping Poles Carton Weight lbs. (kg) (0.4) (0.9) (1.2) Lugs For 60/5 C Wire NGB Ampere Rating Wire Size 15 30A #14 #6 AWG Cu #12 #6 AWG Al A #8-1/0 AWG Cu #8-2/0 AWG Al GB Type LGB (Panelboard Mount) Integral with breaker Integral with breaker 40 C 15 LGB1B015B a b LGB2B015B b LGB3B015B b 20 LGB1B020B a b LGB2B020B b LGB3B020B b 25 LGB1B025B b LGB2B025B b LGB3B025B b 30 LGB1B030B b LGB2B030B b LGB3B030B b 35 LGB1B035B b LGB2B035B b LGB3B035B b 40 LGB1B040B b LGB2B040B b LGB3B040B b 45 LGB1B045B b LGB2B045B b LGB3B045B b 50 LGB1B050B b LGB2B050B b LGB3B050B b 60 LGB1B060B LGB2B060B LGB3B060B 0 LGB1B00B LGB2B00B LGB3B00B 80 LGB1B080B LGB2B080B LGB3B080B 90 LGB1B090B LGB2B090B LGB3B090B 100 LGB1B100B LGB2B100B LGB3B100B 110 LGB1B110B LGB2B110B LGB3B110B 125 LGB1B125B LGB2B125B LGB3B125B Interrupting Ratings (max. RMS symmetrical amperes ka) NGB HGB LGB UL489 Volts AC Volts DC Poles Y/34 600Y/ / , , , aswd rated. bhid rated. c2-pole only. 2-pole only or two outer poles of 3-pole breaker For external accessories, please refer to pages -95 to -100 For internal accessories, please refer to page -34 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -33
6 Accessories a 08/02/13 Shunt Trip BQD, BQD6, CQD, CQD6, Control NGG, HGG, LGG, NGB, HGB and LGB V AC V DC 120 CQDST CQDST240s 2 CQDST2s 480 CQDST480s 600 CQDST CQDST CQDST CQDST CQDST125 Auxiliary Switch Maximum AC DC Number of Contacts A 1B CQDA A 2B CQDA2 BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB CQD with Accessory Installed Alarm Switch Maximum AC DC CQDBA BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB Shunt Trip and Auxiliary Switch Combinations Shunt Trip AC DC BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB 24 CQDST24AASs 120 CQDST120AASs 240 CQDST240AASs 2 CQDST2AASs 480 CQDST480AASs 600 CQDST600AASs 12 CQDST12DASs 24 CQDST24DASs 48 CQDST48DASs 125 CQDST125DASs Alarm and Auxiliary Switch Combinations For Breaker BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB and LGB CQDA1BAs s Built to order. Allow 6 8 weeks for delivery. a Adds 1-pole space for accessory. -34 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog
7 NEB & HEB Frame Type NEB (Panelboard 40 C 15 NEB1B015B a b NEB2B015B b NEB3B015B 20 NEB1B020B a b NEB2B020B b NEB3B020B 25 NEB1B025B b NEB2B025B b NEB3B025B 30 NEB1B030B b NEB2B030B b NEB3B030B 35 NEB1B035B b NEB2B035B b NEB3B035B 40 NEB1B040B b NEB2B040B b NEB3B040B 45 NEB1B045B b NEB2B045B b NEB3B045B 50 NEB1B050B b NEB2B050B b NEB3B050B 60 NEB1B060B NEB2B060B NEB3B060B 0 NEB1B00B NEB2B00B NEB3B00B 80 NEB1B080B NEB2B080B NEB3B080B 90 NEB1B090B NEB2B090B NEB3B090B 100 NEB1B100B NEB2B100B NEB3B100B 110 NEB1B110B NEB2B110B NEB3B110B 125 NEB1B125B NEB2B125B NEB3B125B Front view HEB 06/20/13 Back view Type HEB (Panelboard 40 C 15 HEB1B015B a b HEB2B015B b HEB3B015B 20 HEB1B020B a b HEB2B020B b HEB3B020B 25 HEB1B025B b HEB2B025B b HEB3B025B 30 HEB1B030B b HEB2B030B b HEB3B030B 35 HEB1B035B b HEB2B035B b HEB3B035B 40 HEB1B040B b HEB2B040B b HEB3B040B 45 HEB1B045B b HEB2B045B b HEB3B045B 50 HEB1B050B b HEB2B050B b HEB3B050B 60 HEB1B060B HEB2B060B HEB3B060B 0 HEB1B00B HEB2B00B HEB3B00B 80 HEB1B080B HEB2B080B HEB3B080B 90 HEB1B090B HEB2B090B HEB3B090B 100 HEB1B100B HEB2B100B HEB3B100B 110 HEB1B110B HEB2B110B HEB3B110B 125 HEB1B125B HEB2B125B HEB3B125B Load lugs are included as standard. HACR rated. Shipping Weights Number of Number per Shipping Poles Carton Weight lbs. (kg) (0.5) (0.9) (1.4) Lugs For 60/5 C Wire NEB/HEB Ampere Rating Wire Size A #14 1/0 3TA1EG10 (kit of 3) A #6 3/0 3TA1EG30 (kit of 3) Interrupting Ratings (max. RMS symmetrical amperes ka) UL489/CSA IEC (lcs = 50% lcu) Number Breaker of Volts AC Volts DC Volts AC Volts DC Type Poles Y/34 125/ / NEB 2, HEB 40 C, 50/60Hz , SWD Rated HID Rated For external accessories, please refer to pages -95 to -100 For internal accessories, please refer to page -36 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog -35
8 Internal Accessories for NEG & HEG 125A Frame, NEB & HEB 125A Frame Shunt Trip Control NEG, HEG, NEB, HEB V AC V DC STRER240A 125 STRED125D STREV STREM60D 04/09/12 Auxiliary Switch Maximum Number NEG, HEG, of NEB, HEB AC DC Contacts A 1B ASKE A 2B ASKE3 Alarm Switch Maximum Number NEG, HEG, of NEB, HEB AC DC Contacts A 1B ASKE A 2B ASKE5 Undervoltage Trip Control NEG, HEG, NEB, HEB AC DC 24 UVREB24A 60 UVREM60s 120 UVREN UVRER UVREU480s 600 UVREV600s 24 UVREB24D 48 UVREC48Ds 125 UVRED125Ds 250 UVREE250Ds Alarm and Auxiliary Switch Combinations For Breaker NEG, HEG ASKE6 s Built to order. Allow 6 8 weeks for delivery. -36 Siemens Industry, Inc. SPEEDFAX 2011 Product Catalog
65,000 A IR Catalog Number QA115AFCHH QA120AFCHH. 22,000 A IR Catalog Number. QA115AFHn a QA120AFHn a. Q215AFCHn a Q220AFCHn a QA115AFHH QA120AFHH
Circuit s Arc-Fault and Ground-Fault s 06/3/4 Selection/Wiring Diagrams Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard
More informationPREFACE. The products covered by this Guide are:
PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in
More informationMiniature Circuit Breakers and Supplementary Protectors
Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG
More informationPREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:
PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for electrical inspectors, electric utilities, contractors, installers, users, designers, and other interested parties to aid
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationGeneral information Circuit breakers for power distribution T1 T3
Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480
More informationSentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationDistribution Dry Type Transformers
8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg
More informationVL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers
VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame
More informationCircuit Breaker. Description
Data Bulletin 0739DB9901R11/03 Cedar Rapids, Iowa, USA International Miniature Circuit Breakers with QO Plug-on and Bolt-on Connections Class Number 0739 Retain for future use. GENERAL DESCRIPTION The
More information22,000 A IR. 65,000 A IR Catalog Number. Catalog Number. MPA115AFCHn a MPA120AFCHn a MPA115AFCHH MPA120AFCHH. MP215AFCHn a MP220AFCHn a
Arc-Fault Circuit Interrupters (AFCI) Revised 06//4 Combination Type AFCI b AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect.
More informationBussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1
How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationCircuit Breakers Supplementary Protectors Manual Motor Controllers
WHITE PAPER Circuit Breakers Supplementary Protectors Manual Motor Controllers Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More informationwww.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure.
www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI)
More informationIntroduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution
Table of Contents Introduction...2 Residential Power Distribution...4 Load Centers...6 Load Center Construction...8 Residential Circuit Breakers... 16 Ground Fault Protection...23 Arc Fault Protection...25
More informationDimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationReverse-feed applications for circuit breakers
Technical Publication PU01200001E Contents Description Page Intoduction.......................................................................... 2 breaker classifications..........................................................
More informationSPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents
SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series
More informationBRITISH STYLE SEMICONDUCTOR PROTECTION FUSES
The Edison British Style semiconductor protection fuses include a 660VAC line utilizing new filler technology. These new fuses have greatly reduced peak let-through current and energy under fault conditions
More informationLCP Coordination Panel Operations & Maintenance Manual Table of Contents
LCP Coordination Panel Operations & Maintenance Manual Table of Contents 1. Overview 2. NEC Requirements Overview 3. LCP Coordination Panel Data Sheet 4. Class CC Littelfuse CCMR Current-Limiting Fuse
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationQO and QOB Miniature Circuit Breakers
QO and QOB Miniature s Class CONTENTS Description..................................................... Page General Description and Ratings........................................ Special Application s......................................
More informationMolded case circuit breakers
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationEngineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior
More informationProduct Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors
Product Guide Cable-in / cable-out miniature circuit breakers and supplementary protectors Cable-in / cable-out miniature circuit breakers and supplementary protectors Eaton offers a complete line of
More informationArc Fault Circuit Interrupters Frequently Asked Questions
Contents My AFCI is tripping! What do I do? What is the difference between branch feeder and combination type Arc Fault Circuit Interrupters? What is new with the 2008 NEC versus the 2005 NEC with respect
More informationCHAPTER 2 EXAMPLES AND TABLES
CHAPTER 2 EXAMPLES AND TABLES COMMENTARY AT 210.20(A) EXCEPTION An overcurrent device that supplies continuous and noncontinuous loads must have a rating that is not less than the sum of 100 percent of
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationDistribution Dry Type Transformers
Distribution Dry Type s Sentron Power Centers Bolt-in Breaker Option The same economical space saving package, NEMA 3R rated enclosure, and UL listed transformer of the original Sentron Power Center but
More informationPREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:
PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront
More informationWestinghouse AB DE-ION Current Limiting Circuit Breakers
Cutler-Hammer Westinghouse & Cutler-Hammer Products Five Parkway Center Pittsburgh, Pennsylvania, U.S.A. Application Data -C Page October Mailed to: E/-A Time/Current Characteristic Curves for Westinghouse
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationTerminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire
9080LBA Power Distribution Blocks Copper or Aluminum Wire Class 9080 Miniature Standard Amperage Rating - CU Wire 115 amp. 115 amp. 175 amp. 175 amp. Amperage Rating - AL Wire 90 amp. 90 amp. 135 amp.
More informationTmax. Molded case circuit breakers. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com. Tmax.
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationSwitching Power Module
369357e 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
More informationIndex. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70
Molded case circuit breakers Index Molded case circuit breakers - Molded case circuit breakers Formula...1 -.10 General information Introduction...1 Circuit breakers for power distribution...2 explanation...3
More informationCorner-Grounded Delta (Grounded B Phase) Systems
Data Bulletin 2700DB0202R03/12 09/2012 Replaces 2700DB0202R2/09 dated 02/2009 Corner-Grounded Delta (Grounded B Phase) Systems Class 2700 Retain for future use. Introduction Corner-grounded delta systems
More informationDC disconnects for solar photovoltaic installations. Connecting the. power of the sun
DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these
More informationELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
More informationAC1645. System pro M compact Supplementary Protectors Miniature MCCBs
AC1645 System pro M compact Supplementary Protectors Miniature MCCBs Table of Content 1 2 3 4 5 pro M compact General information...1.1 S200 - Supplementary protectors...1.7 S200U - Miniature MCCBs...1.12
More informationElectronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600
Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents
More informationDecision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features
Decision-Maker Paralleling System Power Distribution Switchboards and Circuit Breakers Power Distribution Switchboards and Circuit Breakers The generator paralleling circuit breakers for the Kohler Decision-Maker
More informationNEC 2014 Code Changes
NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables
More informationGuidelines on the Short Circuit Current Rating for Industrial Control Panels
usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A
More informationCONSIDERATIONS FOR INSTALLATION OF SMOKE ALARMS ON RESIDENTIAL BRANCH CIRCUITS
CONSIDERATIONS FOR INSTALLATION OF SMOKE ALARMS ON RESIDENTIAL BRANCH CIRCUITS October 2005 CPSC-ES-0504 The views expressed in this report are those of the CPSC staff and have not been reviewed or approved
More informationPanelboards 11 PANELBOARDS. Type P2 Panelboards. General
General Features Flexibility is the hallmark of the P2 panel. This panel offers a wide array of factoryassembled options to meet almost all lighting panel applications. With this design, the ability to
More informationHPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80
Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationCITY OF LOS ANGELES CALIFORNIA
BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationApplications. Remote Display Mounting Kits
June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge
More informationBuck - Boost Transformers
Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single
More informationOwner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance
Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:
More informationWhat are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
More informationIntroduction. Upon completion of Basics of Electrical Products, you should be able to:
Table of Contents Introduction... 2 Siemens Industry, Inc... 4 Electric Power... 5 Residential Applications... 10 Commercial Applications... 20 Industrial Applications... 37 Manufacturing Applications...
More informationIntroduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system
Table of Contents Introduction... 2 Distribution Systems... 4 Switchboard Definition... 9 Switchboard Construction... 12 Service Entrance Equipment... 18 Service Section... 20 Switchboard Grounding...
More informationSelection and application guide. Panelboards. usa.siemens.com/panelboards
Selection and application guide Panelboards usa.siemens.com/panelboards 1 SECTION Contents PAGE Introduction 2 General Specifications 3-5 Catalog Numbering System 6 A detailed Table of Contents is located
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationPower Distribution & Terminal Blocks
Power Distribution & Terminal Section Contents Page Selection table for SCCR PDBs & Power terminal blocks................................ 294 Power distribution blocks Series PDBFS enclosed, with high
More informationSecondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
More informationSiemens STEP 2000 Course Basics of Electrical Products
Siemens STEP 2000 Course Basics of Electrical Products It's easy to get in STEP! Download any course. Hint: Make sure you download all parts for each course and the test answer form. Complete each chapter
More informationConnecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations
Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has
More informationDetermining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760
Data Bulletin Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760 Retain for future use. 0760DB0204 Replaces 0760DB0204 R09/07 Precautions DANGER
More informationSWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.
PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general
More informationThe Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2
Residential Load Centers and Circuit Breakers product The Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationASCO SERIES 185 Power Transfer Switches
ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationInstallation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationProtect your home and family with Advanced Technology from Cutler-Hammer
Protect your home and family with Advanced Technology from Cutler-Hammer Residential Home Fire Statistics Annually - over 415,000 Residential Fires Annually - over 40,000 electrical fires over 350 deaths
More informationMining service breakers with true rms sensing designed specifically for trailing cable applications
Eaton Mining Service Circuit Breakers E 2 Series 15 2000 Amperes 600 and 1000 Vac Mining service breakers with true rms sensing designed specifically for trailing cable applications E 2 mining service
More informationSPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
More informationFirst Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO. 49-897
OCA #230100 First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO. 49-897 AN ORDINANCE AMENDING SECTIONS 4.A.080, 4.1.020, 4.1.110, 4.2.010, 4.2.070, 4.2.125, 4.2.170, 4.2.175 AND 4.2.220;
More informationSolar circuit protection application guide. Complete and reliable solar circuit protection
Solar circuit protection application guide Complete and reliable solar circuit protection Introduction Benefits of Eaton s circuit protection solutions Complete and reliable circuit protection for photovoltaic
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationMini Power-Zone Unit Substation
Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3
More informationHow To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply
GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator
More informationInstructions for ND, CND, HND, CHND, NDC and CNDC Circuit Breakers and N-frame Series C Molded Case Switches
Instructions for ND, CND, HND, CHND, NDC and CNDC Circuit Breakers and N-frame Series C Molded Case Switches File 29-000 WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAIN- TENANCE ON EQUIPMENT WHILE ENERGIZED.
More informationCIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS David D. Roybal, P.E. Senior Member, IEEE Eaton Electrical 3697 Mount Diablo Boulevard Lafayette, CA 94549 Abstract Low-voltage circuit
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationProtection Equipment
Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to
More informationSKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
More informationPhase-Adaptive Power Module
369356c 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic
More informationMission Critical Data Center Systems
Mission Critical Systems Mission Critical/ Electrical Distribution Systems Data center electrical distribution designs are rapidly evolving, driven by needs such as increasing power densities, energy efficiency,