65,000 A IR Catalog Number QA115AFCHH QA120AFCHH. 22,000 A IR Catalog Number. QA115AFHn a QA120AFHn a. Q215AFCHn a Q220AFCHn a QA115AFHH QA120AFHH

Size: px
Start display at page:

Download "65,000 A IR Catalog Number QA115AFCHH QA120AFCHH. 22,000 A IR Catalog Number. QA115AFHn a QA120AFHn a. Q215AFCHn a Q220AFCHn a QA115AFHH QA120AFHH"

Transcription

1 Circuit s Arc-Fault and Ground-Fault s 06/3/4 Selection/Wiring Diagrams Arc-Fault Circuit Interrupters (AFCI) AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arcfault is detected. Combination AFCI Detects all three possible types of arc fault: line-to-ground, line-to-neutral, and series. QAF2/QAFH2/HQAF2 -Pole V AC QAF2/QAF2H /240V AC Branch-Feeder AFCI 5 5 0,000 A IR QA5AFC a QAAFC a Q25AFC a Q2AFC a Detects line-to-ground and line-to neutral arcs. 22,000 A IR QA5AFCHn a QAAFCHn a Q25AFCHn a Q2AFCHn a 65,000 A IR QA5AFCHH QAAFCHH -Pole Combination AFCI Combination AFCI QAF2/QAFH2/HQAF2 -Pole V AC 5 QA5AF a QAAF a QA5AFHn a QAAFHn a QA5AFHH QAAFHH NEW Dual Function AFCI/GFCI The Dual Function Circuit combines Combination AFCI and GFCI, protecting against both Arc Faults and Ground Faults. The device includes the Self Test and Lockout feature, making it the fist in class in electrical safety for homeowners. QFGA2/QFGAH2/ HQFGA2 -Pole V AC 5 QA5DF QADF Q5DFH QDFH Q5DFHH QDFHH -Pole Branch Feeder AFCI -Pole Dual Function AFCI/GFC Ground-Fault Circuit Interrupters (GFCI) Ground Fault Equipment Protection (ma) Provides Class A (5mA) ground fault protection. Intended for personnel protection. De-energizes the circuit for all ungrounded conductors of the circuit. F/ HF -Pole V AC Plug-in Amp ,000 A IR No. QF5 a QF a QF25n QF 22,000 A IR No. QF5H a QFHn a QFH Provides protection of equipment from damaging line-to-ground faults currents. De-energizes the circuit for all ungrounded conductors of the circuit. QE/ QEH -Pole V AC Plug-in Amp 5 0,000 A IR No. QE5 a QE a QE 22,000 A IR No. QE5H a QEH a QEH -Pole GFCI GFCI F/ HF / 240V AC Plug-in QF25 QF2 QF2 QF240 QF250 QF260 QF25H QF2H QF2H QF240H QF250H QF260H QE/ QEH / 240V AC Plug-in QE25 QE2 QE2 QE240 QE250 QE260n QE25H QE2H QE2H QE240H QE250H QE260Hn -Pole Equipment Protection Equipment Protection QAF2/F/QE Accessories Wiring Diagrams Description Padlocking Device -Pole ECPLD Padlocking Device ECPLD2 Handle Block ECBX23M n Built to order. Allow 2 3 weeks for delivery. a UL Listed as SWD (Switching Duty) Rated, suitable for V AC Fluorescent Lighting. Siemens Industry, Inc. SPEEDFAX Product -9

2 Circuit s with INSTA-WIRE H H Continuous Current 0,000A IR 22,000A IR 65,000A 40 C -Pole Plug-In (V AC) e 0 Q0 5 Q5c Q5H c Q5HHn c Qc QH c QHHn c 25 Q25 Q25Hn Q25HHn Q QH QHHn 35 Q35n Q35Hn Q35HHn 40 Q40 Q40H Q40HHn 45 Q45n Q45Hn Q45HHn 50 Q50 Q50H Q50HHn 60 Q60 Q60Hn Q60HHn 0 Q0 Q0Hn Q0HHn Plug-In (Common-Trip /240V AC) 0 Q 5 Q25 Q25H Q25HH Q2 Q2H Q2HH 25 Q225 Q225Hn Q225HHn Q2 Q2H Q2HH 35 Q235 Q235Hn Q235HHn 40 Q240 Q240H Q240HHn 45 Q245 Q245Hn Q245HHn 50 Q250 Q250H Q250HH 60 Q260 Q260H Q260HH 0 Q20 Q20H Q20HH 80 Q280 Q280Hn Q280HHn 90 Q290 Q290H Q290HHn 00 Q0 Q0H Q0HH 0 Q QH QHHn 25 Q225 Q225H Q225HH Plug-In (Common-Trip 240V AC) 5 Q25R Q2R Q2R 40 Q240R 50 Q250R 60 Q260R 0 Q20R 00 Q0Rn 3-Pole Plug-In (Common-Trip 240V AC) 5 Q35 Q35H Q35HHn Q3 Q3H Q3HH 25 Q325 Q325Hn Q325HHn Q3 Q3H Q3HH 35 Q335 Q335Hn Q335HHn 40 Q340 Q340H Q340HH 45 Q345 Q345Hn Q345HHn 50 Q350 Q350H Q350HH 60 Q360 Q360H Q360HH 0 Q QH QHHn 80 Q380 Q380H Q380HHn 90 Q390 Q390H Q390HHn 00 Q0 Q0H Q0HH 03/06/3 Selection / H / H Internal Accessories Control Voltage AC Field/Factory Installed V Shunt Trip add suffix 00S0n Factory 24V Shunt Trip add suffix 00S0n Factory V Auxiliary Switch add suffix 0n b Factory Modifications Description 400 Hz Calibration add suffix Y h Marine 50 C Ambient Calibration add suffix M Fungus Proofing add suffix F For external accessories, please refer to page -93 n Built to order. Allow 2-3 weeks for delivery. a UL Listed for use with 60/5 wire through 40 amps, UL listed for use with 5 wire only for 50 amps and above, HACR rated. b A and B contacts. c UL Listed for frequent switching applications (SWD). V AC Fluorescent Lighting. d UL Listed for use on 3-phase grounded B systems 0,000 for this application. e Shipped 2 per sleeve. f Shipped 6 per sleeve. g Shipped 4 per sleeve. h UL Listed 5 KA IR. i, UL listed for 6 AWG conductors and multiple wires. - Siemens Industry, Inc. SPEEDFAX Product

3 Circuit s Duplex, Triplex and Quadplex Plug-In s Duplex Circuit s QT -Pole 0K AIC V AC Triplex Circuit s QT 0K AIC /240V AC Inner Poles Common Trip 5 5 Q55 Q55NC a 5 Q5 Q5NC a Q QNC a Q 5n Q5 Q Q QNC a SHIPPING: 2 per carton, (Wt. 4.8 lbs.) Single Pole Common-Trip 5 5 Q255CT 5 Q25CT 5 25 Q2525CTn 5 Q25CT 5 35 Q2535CTn 5 40 Q2540CT 5 45 Q2545CTn 5 50 Q2550CT Q2CT 25 Q225CTn Q2CT 35 Q235CTn 40 Q240CT 45 Q245CTn 50 Q250CT Q2CT SHIPPING: 6 per carton, (Wt. 4.9 lbs.) 04//3 Selection QT Duplex These space saver duplex breakers combine two independent /2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated. QT Triplex These space saver triplex breakers provide a 2-pole common trip breaker for /240V AC circuits and two single poles for V AC circuits. Triplex require two panel spaces. HACR rated. Quadplex Circuit s QT 0K AIC /240V AC Inner and Outter 2 Poles Common Trip Common-Trip Inside Common-Trip Outside 5 5 Q255CT2 Q2CT2 Q2CT2 40 Q240CT2 Q2CT2 40 Q240CT Q24040CT2 50 Q250CT2 SHIPPING: 6 per carton, (Wt. 4.8 lbs.) QT Quadplex These space saver quadplex breakers provide two sets of common trip, two-pole breakers for /240V AC circuits, and require two panel spaces. HACR rated. For external accessories, please refer to page -93 For inches / millimeters conversion, see Application Data section. n Built to order. Allow 2 3 weeks for delivery. a Non-CTL. For replacement use only in panels manufactured before 968 Siemens Industry, Inc. SPEEDFAX Product -2

4 Circuit s Special Application s Selection HID Lighting For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. -Pole V AC /240V AC Wiring Diagram Figure Figure 2 Complete UL Unenclosed 5 Q5HID a n QHID a QHID 5 Q25HID Q2HIDn Q2HIDn Molded Case Switch For applications that do not require overcurrent protection. -Pole V AC /240V AC Figure 00 Q00S Figure Q2S Q260S Q225S Switching Neutral No-Noise For applications that require a reduction in the 60-cycle hum of a standard breaker. /240V AC Figure 2 50 Q250NNn 60 Q260NN 0 Q20NN 90 Q290NNn Switching Neutrals Used where all conductors are required to be disconnected. Neutral pole of the circuit breaker does not connect to load center bus. One side is wired to neutral and the other side to the device. QG 2-Wire Common Trip V AC QG 3-Wire Common Trip /240V AC Figure 3 Figure QG25 QG2 QG2n QG35n QG3 QG3n Tungsten Lighting For high wattage, tungsten-lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. -Pole V AC Figure 5 Q5T a n QT a Water Heater Figure Figure 2 Figure 3 Figure 4 Figure 5 Water Heater When installed in a loadcenter, the water heater circuit breaker does not make electrical connection with the loadcenter bussing. Separate metered circuit is connected to line terminals of the breaker. Used in special rate water heating areas. Wiring Diagrams QW /40V AC Plug-In Figure 5 5 QW25 QW2 QW2 n Built to order. Allow 2 3 weeks for delivery. Note: All circuit breakers on this page are 0K AIC a UL Listed as SWD (Switching Duty) Rated, suitable for V AC Fluorescent Lighting. -22 Siemens Industry, Inc. SPEEDFAX Product

5 Circuit s 3/4 Inch Plug-In s Selection Features b 3/4" format b HACR Rated b UL Classified for use in certain Square D load centers QD Circuit s The QD circuit breaker line is available in -pole and 2-pole common trip versions listed on this page. The circuit breakers are UL Classified and UL Listed. All QD breakers are supplied with load side connectors suitable for 60/5 C wire and are calibrated for 40 C maximum ambient applications. UL Classified Siemens QD circuit breakers are UL Classified for use in specific Square D load centers in place of Square D QO circuit breakers. A Panelboard Compatibility List packaged with each QD breaker shows which type QD circuit breakers are acceptable for use in Square D load centers. The interrupting rating on these circuit breakers is 0,000A IR maximum and they are not series rated with Square D circuit breakers or equipment. This UL Classification allows a Siemens QD circuit breaker to be used in place of a Square D QO circuit breaker in those load centers that are specifically shown on the Panelboard Compatibility list. For additional information, contact your local Siemens sales engineer. -Pole Continuous Current V /240V Common 40 C 5 D5 a D25 D a D2 D D2 40 D40 D D50 D D60 D260 Shipping Weights of Per Shipping Poles Carton Weight (lbs.) Panelboard Compatibility List Listed Panelboards Square D s QO2LF/S QO2-4L0F/S QO2-4L0TS QO2-4L0RB QO6-2L00F/S QO6-2L00DF/S QO6-2L00TF/S QO6-2L00DTF/S QO6-2L00RB QO8-6L00F/S QO8-6L00DF/S QO8-6L00TF/S QO-6L00DTF/S QO8-6L00RB QO2M00/RB QO6M00/RB QOM00/RB QO24M00 QO2L00DF/S QO2L00RB QO2-M00/RB QO2-M00TF/S QO2M00/RB QO6-M00/RB QO6M00/RB QOM00/RB QO2L25G/RB QO2-24L25/RB QO2-24L25GWGC QO6L25G QO6-24L25G/RB QO2-24L25/RB QO-24L25G QO-24L25GWGC QOL25G QO24L25G/RB QO24M25/RB QO6L25/RB QO6-2M25FTRB QO6-24L25/RB QOL25/RB QO-24L25/RB QO24L25/RB QO-L50G QO-M50/RB QO24L50G QO24M50 QOL50G/RB QOM50/RB QO6L50/RB QO6M50/RB QO6-L50/RB QO8-6M50FTRB QO-M50/RB QO-M50TF/S QO-L50 QO24L50/RB QO24M50/RB QOL50/RB QOM50/RB QO8-6M0FT/RB QO2L0G/RB QO-40M0/RB QO-40M0TC QO24M0 QOL0G/RB QO-40M0 QO0/RB QO-40L0G/RB QO40M0/RB QO6L0/RB QO6M0/RB QO8-6M0FTRB QO-40L0/RB QO-40M0TF/S QO-40M0/RB QO24L0/RB QO24M0/RB QOL0/RB QOM0/RB QO-40L0/RB QO-40M0/RB QO40M0/RB QO40M225 QO42L225G/RB For inches / millimeters conversion, see Application Data section. a UL Listed for frequent switching applications (SWD). V AC Fluorescent Lighting. One or two load conductors. Siemens Industry, Inc. SPEEDFAX Product -23

6 Circuit s Main and Branch Circuit s a /05/3 Selection QN /240V AC QNH /240V AC 50 QN250 QN250R b 0 5 QN25n QN25R b n 0 0 QN20 QN20R b 0 50 QN250H QN250RH b 22 5 QN25Hn QN25RH b n 22 0 QN20H QN20RH b HQN250 HQN250R b 65 5 HQN25n 65 UL Interrupting s (ka) HQN /240V AC 0 HQN20 HQN20R b 65 Requires 4 panel spaces, 2 adjacent and 2 opposite. SHIPPING: per carton (Wt. 3 lbs.) Main Kits For use in Ultimate Load Centersd For use in EQIII Load Centers UL UL EQ MBK00A EQ MBK00 22 EQ MBK25A EQ96 25 MBK25 22 EQ MBK50A EQ MBK50 22 EQ MBK5n 22 EQ MBK0A EQ MBK0 22 EQ MBK225A EQ MBK UL Interrupting s (ka) QNR e EQ96XX QN e J c 3-Pole 240V AC 25 J J J 0 UL Interrupting s (ka) Requires 6 spaces due to cross over design. Fits only EQIII A 3-phase load centers SHIPPING: 5 per carton (Wt. lbs.) MBK (00,25)A MBK (50,0,225)A P /240V AC PH /240V AC HP /240V AC HPH /240V AC 25 Q225B 0 50 Q250B 0 5 Q25Bn 0 0 Q20B Q2225B 0 25 Q225BH Q250BH 22 5 Q25BHn 22 0 Q20BH Q2225BHn Q225BHHn Q250BHH 65 5 Q25BHHn 65 0 Q20BHH Q2225BHHn HQ0BHn HQ225BHn HQ250BHn 00 5 HQ25BHn 00 0 HQ20BHn HQ2225BHn 00 UL Interrupting s (ka) Volts AC /240 P J For inches / millimeters conversion, see Application Data section. n Built to order. Allow 2 3 weeks for delivery. a All circuit breakers on this page are common trip. b Reverse handle. c CSA Listed. d MBK00A for use in 00 and 25A load centers. MBK25A for use in 25A load centers. MBK50A for use in 50, 0 and 225A load centers. MBK0A for use in 0 and 225A load centers. MBK225A for use in 225A load centers. MBK5A for use in 0 and 225A load centers. e QNR required for horizontal applications or vertical applications where the lugs are facing up. The QN breaker is required for vertical applications where the lugs are facing down as shown. -24 Siemens Industry, Inc. SPEEDFAX Product

7 Circuit s Main and Branch Circuit s QS PowerMod's core offering of residential Meter Stacks, type WMM, offers the widest product offering & flexibility in the industry. Each meter stack houses the QuickSystem features to maximize productivity and minimize labor costs. To further simplify installation, our 225 Amp meter stacks feature the QS breaker. The QS breaker adds to the Siemens exclusive feature set in our Power Mod product line. Benefits and part numbers include: Front View An exclusive side wired design saves wiring space and eliminates difficult "S bends" No need for costly filler plates QS 225 Amp breaker takes the same space as standard 00 Amp s Single right hand bend wiring - saves time and wire Provides 00K AIC flexibility from 00 up to 225 Amps 0K to 00K AIC Series QS QS QSH QSHH HQS HQSH Amperage 0K AIC 22K AIC 42K AIC 65K AIC 00K AIC 00 QS0 QS0H QSH0 QS0HH HQS0H 25 QS225 QS225H QSH225 QS225HH HQS225H 50 QS250 QS250H QSH250 QS250HH HQS250H 5 QS25 QS25H QSH25 QS25HH HQS25H 0 QS20 QS20H QSH20 QS20HH HQS20H 225 QS2225 QS2225H QSH2225 QS2225HH HQS2225H QS Dimension Drawing CAUTION PRECAUCION A ON 2.22 NEUTRAL.99 OFF For PowerMod information, please refer to Section 2, page 2-49 Siemens Industry, Inc. SPEEDFAX Product -25

8 Circuit s Line Diagrams 06/3/4 Dimension Drawings -Pole 3-Pole 3" 2 3 /8" 3 /8", H, H QT F, HF, QE, QAF2, QAF2H EQ868, EQ8682 EQ8693, EQ8695, EQ8696 J QN, QNH, HQN QNR, QNRH, HQNR P, PH, HP, HPH a All standard circuit breakers are calibrated to 40 C maximum ambient application. -26 Siemens Industry, Inc. SPEEDFAX Product

9 Circuit s Lug Data Circuit Circuit LOAD SIDE Cables Per Connector Connector Wire Range, H, H, Plug-in 0 2 #4-#6 AWG Cu QT 5 35 #4 #6 AWG Cu #4 #6 AWG Al #8 #6 AWG Cu #8 #4 AWG Al #8-#2/0 AWG Cu #8-#2/0 AWG Al #4 #6 AWG Cu #4 #6 AWG Al 40 #8 AWG CU-Al F, HF 5 QAF2, QAFH2, QFGA2, QFGAH #8 #6 AWG Cu #8 #4 AWG Al #4 #0 AWG Cu #2 #8 AWG Al #8 #6 AWG Cu #8 #4 AWG Al #4 #2 AWG Cu #2 #0 AWG Al QD 5 2 #4 #8 AWG Cu Only #4 #2 AWG Cu 5 #2 #0 AWG Al #0 #8 AWG Cu #0 #6 AWG Al #8 #6 AWG Cu #8 #4 AWG Al QN, QNH, HQN 50 0 # 0kcmil Cu-Al QS, QSH, QSHH, HQS, HQSH #3 0kcmil Cu-Al EQ868-Ultimate 00 #4 3/0 AWG Cu-Al EQ8682-Ultimate 25 #4 3/0 AWG Cu-Al EQ8693-Ultimate 50 # 0kcmil Cu-Al 06/3/4 Reference EQ8695-Ultimate 0 # 0kcmil Cu-Al EQ8696-Ultimate 225 # 0kcmil Cu-Al P, PH, HP, HPH EQ965-EQIII 00 EQ96-EQIII 25 EQ9683-EQIII 50 EQ EQ9685-EQIII 0 EQ9686-EQIII 225 # AWG Cu #2/0 AWG Al #/0 AWG Cu #3/0 AWG Al #2/0 AWG Cu #4/0 AWG Al #3/0 AWG Cu 250kcmil AWG Al #4/0 AWG Cu 0kcmil AWG Al #8-#2/0 AWG Cu #8-#2/0 AWG Al #8-#2/0 AWG Cu #8-#2/0 AWG Al #/0 AWG Cu #3/0 AWG Al #3/0 AWG Cu 250kcmil AWG AL #3/0 AWG Cu 250kcmil AWG Al #4/0 AWG Cu 0kcmil AWG Al J 25 0 #2 0kcmil Cu-Al Siemens Industry, Inc. SPEEDFAX Product -2

10 Surge Protection Circuit and Surge Protective Device (SPD) Features 2 inch wide plug-on design Includes (2) Pole circuits breakers No loss of load center spaces Easy to install and perfect for retrofit LEDs provide protection status Circuit and Surge Protective Device (SPD) Benefits By installing a Siemens Circuit and Surge Protective Device (SPD) in the load center of the residence, surge protection is provided for all branch circuits. Two green LED indicator lights are provided to show that surge protection is provided for all circuits connected to the load center. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided. The circuit breaker and SPD utilize Siemens-built 50V AC, 40mm, metal oxide varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The standard interrupting rating for the circuit breakers is 0k AIC. All circuit breakers and SPD are plug-on style, with load terminals provided. The devices are rated for /240V AC and are calibrated for 40 degrees C maximum ambient applications. Surge - Pole /240V AC 0K AIC (2) 5 (2) QSA55SPD QSASPD SPD SPD Amperage of Poles Initial Clamping Level Transient Energy Transient Suppression Voltage Peak Current (impulse) Discharge Voltage Characteristic Discharge Current Withstand Circuit Interrupting Listings/Certifications QSA55SPD QSASPD 5 or Amp (2) -Pole Circuit s 240 Volts 360 Joules line-to-neutral Joules line-to-line 500 volts peak, line-to-neutral 000 volts peak, line-to-line 40, ,000A, 800 volts (both line-to-neutral) 0,000 amperes line-to-neutral 0,000A, /240V AC UL, CSA Meets UL 449 3rd Edition For warranty information please refer to the surge website Siemens Industry, Inc. SPEEDFAX Product

22,000 A IR. 65,000 A IR Catalog Number. Catalog Number. MPA115AFCHn a MPA120AFCHn a MPA115AFCHH MPA120AFCHH. MP215AFCHn a MP220AFCHn a

22,000 A IR. 65,000 A IR Catalog Number. Catalog Number. MPA115AFCHn a MPA120AFCHn a MPA115AFCHH MPA120AFCHH. MP215AFCHn a MP220AFCHn a Arc-Fault Circuit Interrupters (AFCI) Revised 06//4 Combination Type AFCI b AFCI s detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect.

More information

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure.

www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. www.usa.siemens.com/retail Retail Reference Guide Answers for infrastructure. Arc Fault Circuit Interrupters (AFCI) www.usa.siemens.com/afci Definition of product: Arc fault circuit interrupter (AFCI)

More information

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents SPEEDFAX TM 20 Load Centers & Circuit Breakers Contents Load Centers ing System -2 Siemens PL and ES Series Load Centers Introduction -3 PL Series Load Centers Features and Product Offering -4-5 PL Series

More information

Miniature Circuit Breakers and Supplementary Protectors

Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG

More information

PREFACE. The products covered by this Guide are:

PREFACE. The products covered by this Guide are: PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for electrical inspectors, electric utilities, contractors, installers, users, designers, and other interested parties to aid

More information

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution Table of Contents Introduction...2 Residential Power Distribution...4 Load Centers...6 Load Center Construction...8 Residential Circuit Breakers... 16 Ground Fault Protection...23 Arc Fault Protection...25

More information

The Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2

The Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation 2 Residential Load Centers and Circuit Breakers product The Ultimate Load Center Features 1 2 3 4 5 6 7 8 9 10 11 12 1 INSTA-WIRE neutrals and grounds provide quick and easy neutral conductor installation

More information

Applications. Remote Display Mounting Kits

Applications. Remote Display Mounting Kits June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge

More information

Circuit Breaker. Description

Circuit Breaker. Description Data Bulletin 0739DB9901R11/03 Cedar Rapids, Iowa, USA International Miniature Circuit Breakers with QO Plug-on and Bolt-on Connections Class Number 0739 Retain for future use. GENERAL DESCRIPTION The

More information

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760

Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760 Data Bulletin Determining the Cause of AFCI Tripping Branch/Feeder and Combination Arc Fault Circuit Interrupters Class 760 Retain for future use. 0760DB0204 Replaces 0760DB0204 R09/07 Precautions DANGER

More information

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

What are the basic electrical safety issues and remedies in solar photovoltaic installations? What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic

More information

Reverse-feed applications for circuit breakers

Reverse-feed applications for circuit breakers Technical Publication PU01200001E Contents Description Page Intoduction.......................................................................... 2 breaker classifications..........................................................

More information

Arc Fault Circuit Interrupters Frequently Asked Questions

Arc Fault Circuit Interrupters Frequently Asked Questions Contents My AFCI is tripping! What do I do? What is the difference between branch feeder and combination type Arc Fault Circuit Interrupters? What is new with the 2008 NEC versus the 2005 NEC with respect

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Protect your home and family with Advanced Technology from Cutler-Hammer

Protect your home and family with Advanced Technology from Cutler-Hammer Protect your home and family with Advanced Technology from Cutler-Hammer Residential Home Fire Statistics Annually - over 415,000 Residential Fires Annually - over 40,000 electrical fires over 350 deaths

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

Installation and Operation Guide for PD4000 Series Power Control Center

Installation and Operation Guide for PD4000 Series Power Control Center Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 400-408.55 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 4 Equipment for General Use ARTICLE 400 Flexible Cords and Cables 400.4 Types Flexible cords and flexible cables

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

CHAPTER 2 EXAMPLES AND TABLES

CHAPTER 2 EXAMPLES AND TABLES CHAPTER 2 EXAMPLES AND TABLES COMMENTARY AT 210.20(A) EXCEPTION An overcurrent device that supplies continuous and noncontinuous loads must have a rating that is not less than the sum of 100 percent of

More information

CPS 100 480Y S K CPS 100 480Y S C

CPS 100 480Y S K CPS 100 480Y S C Ref. No. 1299 Visor Series Ordering Guidelines Table.1-4. Retrofit Surge Protection Products TVSS General Description Clipper Power System Visor Series CPS 100 480Y S K.1-9 Surge Ratings 100 = /phase 120

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

QO and QOB Miniature Circuit Breakers

QO and QOB Miniature Circuit Breakers QO and QOB Miniature s Class CONTENTS Description..................................................... Page General Description and Ratings........................................ Special Application s......................................

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Corner-Grounded Delta (Grounded B Phase) Systems

Corner-Grounded Delta (Grounded B Phase) Systems Data Bulletin 2700DB0202R03/12 09/2012 Replaces 2700DB0202R2/09 dated 02/2009 Corner-Grounded Delta (Grounded B Phase) Systems Class 2700 Retain for future use. Introduction Corner-grounded delta systems

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

Mini Power-Zone Unit Substation

Mini Power-Zone Unit Substation Catalog 7440CT0901 2009 Class 7440 CONTENTS Description............................................. Page Product Description...........................................2 General Information...........................................3

More information

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1 Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to

More information

Continuous Power... Continuous Protection

Continuous Power... Continuous Protection Series 165 We Keep Your Power On Continuous Power... Continuous Protection An Automatic Transfer Switch helps prevent... Your business or home from losing power during bad weather or utility power equipment

More information

Introduction. Upon completion of Basics of Electrical Products, you should be able to:

Introduction. Upon completion of Basics of Electrical Products, you should be able to: Table of Contents Introduction... 2 Siemens Industry, Inc... 4 Electric Power... 5 Residential Applications... 10 Commercial Applications... 20 Industrial Applications... 37 Manufacturing Applications...

More information

Engineers Edge, LLC PDH & Professional Training

Engineers Edge, LLC PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

CONSIDERATIONS FOR INSTALLATION OF SMOKE ALARMS ON RESIDENTIAL BRANCH CIRCUITS

CONSIDERATIONS FOR INSTALLATION OF SMOKE ALARMS ON RESIDENTIAL BRANCH CIRCUITS CONSIDERATIONS FOR INSTALLATION OF SMOKE ALARMS ON RESIDENTIAL BRANCH CIRCUITS October 2005 CPSC-ES-0504 The views expressed in this report are those of the CPSC staff and have not been reviewed or approved

More information

Installation Instructions

Installation Instructions H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.

More information

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Guidelines on the Short Circuit Current Rating for Industrial Control Panels usa.siemens.com/sccr Guidelines on the Short Circuit Current Rating for Industrial Control Panels Technical Paper for Practical Applications White Paper I October 2014 As per NEC Edition 2014, and UL508A

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to: PREFACE UL developed the Dead-Front Switchboard Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in understanding deadfront

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

Circuit Breakers Supplementary Protectors Manual Motor Controllers

Circuit Breakers Supplementary Protectors Manual Motor Controllers WHITE PAPER Circuit Breakers Supplementary Protectors Manual Motor Controllers Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected

More information

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications Product Description Product Description The Mini Power-Zone Unit Substation from Schneider Electric is a miniaturized version of our Power-Zone Unit Substation. Included are: Circuit Breaker Sealed Step-Down

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves White Paper July 2010 Integrating surge protective devices (SPD) into distribution equipment (i.e. switchgear, switchboards,

More information

Circuit Breakers. Next Generation of Protection Capabilities

Circuit Breakers. Next Generation of Protection Capabilities Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not

More information

Construction Electrical Terminology. Electricians

Construction Electrical Terminology. Electricians Construction Electrical Terminology Electricians Acknowledgments Winnipeg Technical College and the Department of Labour and Immigration of Manitoba wish to express sincere appreciation to all contributors.

More information

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance

Owner s Manual. For Automatic Transfer Switch. 100-200 Amp, Service Entrance/Non-Service Entrance Owner s Manual For Automatic Transfer Switch 100-200 Amp, Service Entrance/Non-Service Entrance Model Numbers RTST100A3 RTSP100A3 RTST150A3 RTST200A3 RTSP200A3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

More information

Switching Power Module

Switching Power Module 369357e 1 06.22.16 Description Provides capability for a zone on a GRAFIK Eye control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic

More information

Siemens STEP 2000 Course Basics of Electrical Products

Siemens STEP 2000 Course Basics of Electrical Products Siemens STEP 2000 Course Basics of Electrical Products It's easy to get in STEP! Download any course. Hint: Make sure you download all parts for each course and the test answer form. Complete each chapter

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training. 2002 Eaton Corporation. All rights reserved.

UL 508A Industrial Control Panels Power Distribution and Control. Lunch & Learn Training. 2002 Eaton Corporation. All rights reserved. UL 508A Industrial Control Panels Power Distribution and Control Lunch & Learn Training 2002 Eaton Corporation. All rights reserved. Agenda Who is UL and what role do they play? What is the UL 508A Standard?

More information

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

LCP Coordination Panel Operations & Maintenance Manual Table of Contents

LCP Coordination Panel Operations & Maintenance Manual Table of Contents LCP Coordination Panel Operations & Maintenance Manual Table of Contents 1. Overview 2. NEC Requirements Overview 3. LCP Coordination Panel Data Sheet 4. Class CC Littelfuse CCMR Current-Limiting Fuse

More information

Parallel Redundant Uninterruptible Power Supply

Parallel Redundant Uninterruptible Power Supply 9 315 Parallel Redundant Uninterruptible Power Supply Installation/Operation Manual 164202013 Rev. D ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS This guideline has been prepared to assist the owner/occupant of a single family dwelling with compliance to the requirements of the National Electrical

More information

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to

More information

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system

Introduction. Upon completion of Basics of Switchboards you should be able to: Explain the role of switchboards in a distribution system Table of Contents Introduction... 2 Distribution Systems... 4 Switchboard Definition... 9 Switchboard Construction... 12 Service Entrance Equipment... 18 Service Section... 20 Switchboard Grounding...

More information

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

VL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers

VL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame

More information

First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO. 49-897

First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO. 49-897 OCA #230100 First Published in The Wichita Eagle on January 2, 2015 ORDINANCE NO. 49-897 AN ORDINANCE AMENDING SECTIONS 4.A.080, 4.1.020, 4.1.110, 4.2.010, 4.2.070, 4.2.125, 4.2.170, 4.2.175 AND 4.2.220;

More information

Short Circuit Current Calculations

Short Circuit Current Calculations Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B SURGE PROTECTIVE DEVICES (SPDs) EXTERNAL SIDEMOUNT UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors

Product Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors Product Guide Cable-in / cable-out miniature circuit breakers and supplementary protectors Cable-in / cable-out miniature circuit breakers and supplementary protectors Eaton offers a complete line of

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Power surges can also be generated by equipment in your facility such as:

Power surges can also be generated by equipment in your facility such as: Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement

More information

How To Test A Power Switch On A Power Supply

How To Test A Power Switch On A Power Supply transfer switches Soft load Innovative, reliable, integrated solution Built with years of experience Powered with innovation Delivered with reliability A history of experience, innovation and reliability

More information

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT Are You Ready For The New SCCR Marking Requirements? What Is A Short-Circuit Current Rating (SCCR)? SCCRs on components

More information

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600 Data Bulletin 0600DB1104 03/2012 Retain for future use. Electronic Trip Circuit Breaker Basics 0600DB1104 Table of Contents

More information

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D 12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section

More information

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W

Meter Centers. Meter Combination Catalog Number Logic. Combination Meter Sockets MC 30 40 B 1 200 S E C W Centers Combination Catalog Number Logic Combination Sockets MC 30 40 B 1 00 S E C W ere (max. circuits) (max. 1" breakers) MM = MC = Load Center Combination 1 = 1-Phase 3 = 3-Phase ML or L = Lug MB or

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

AFCIs Come of Age. by Douglas Hansen

AFCIs Come of Age. by Douglas Hansen AFCIs Come of Age by Douglas Hansen Arc Fault Circuit Interrupters were the new kid on the block when they first appeared in the 1999 National Electrical Code (NEC). Since then we have seen the technology

More information

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.) Common Electrical Hazards in the Workplace Including Arc Flash Presented by Ken Cohen, PhD, PE & CIH (Ret.) 1 What s New In February 1972, OSHA incorporated the 1971 edition of the National Fire Protection

More information

Power Management Module 2. Installation

Power Management Module 2. Installation Power Management Module 2 30 300 kva Installation Table of Contents Safety... 1 Safety Instructions... 1 Certification Standards Three Phase... 1 Product Safety... 2 Special Precautions... 2 System Description...

More information