Product Data. Features/Benefits. AQUASNAP 30RAP Air-Cooled Chillers with PURON Refrigerant (R-410A)

Size: px
Start display at page:

Download "Product Data. Features/Benefits. AQUASNAP 30RAP010-060 Air-Cooled Chillers with PURON Refrigerant (R-410A)"

Transcription

1 Product Data AQUASNAP 3RAP1-6 Air-Cooled Chillers with PURON Refrigerant (R-41A) 1 to 6 Nominal Tons (35 to 21 Nominal kw) a a The AquaSnap chiller is an effective allin-one package that is easy to install and easy to own. AquaSnap chillers operate quietly and efficiently. Valueadded features include: Rotary scroll compression HFC Puron refrigerant (R-41A) Low-sound AeroAcoustic fan system Easy to use ComfortLink controls Optional integrated hydronic pump package with VFD (variable frequency drive) compatible motors Microchannel condenser coil technology Accessory fluid storage tank Optional digital scroll compressors Features/Benefits Carrier s superior chiller design provides savings at initial purchase, at installation, and for years afterward. Costs less right from the start Carrier s AquaSnap chillers feature a compact, all-in-one package design that installs quickly and easily on the ground or the rooftop. The optional pump and hydronic components are already built in; this costs less than buying and installing the components individually. The chiller s fully integrated and pre-assembled hydronic system installs in minutes. No other chiller in this class installs so easily and inexpensively. The preassembled and integrated hydronic module utilizes top-quality components and pumps to ensure years of reliable operation. Use of the optional fluid storage tank reduces installation costs and ensures sufficient fluid volume is available for closecoupled and process cooling applications. The AquaSnap unit s high efficiency keeps costs down. Copyright 21 Carrier Corporation Form 3RAP-3PD

2 Features/Benefits (cont) AquaSnap chillers make noise in the marketplace, not the workplace. The AquaSnap chiller s low-sound AeroAcoustic fan produces up to half the sound level of propeller fans. Much of the noise reduction is in frequencies where noise is most annoying, which makes AquaSnap chillers ideal for sound-sensitive environments. When lower ambient temperatures allow part-load operation or during scheduled nighttime operation, the units operate with fewer fans and become even quieter. AquaSnap chillers are quiet during the day and even quieter at night. The savings will continue to mount Besides costing less to buy and install, AquaSnap chillers are also more affordable to operate. Carrier s Aqua Series chillers are our most efficient air-cooled models. The AquaSnap chiller provides full-load EER (Energy Efficiency Ratio) up to 1.5 and IPLV (integrated part-load value) up to AquaSnap chillers use ultra-quiet, highefficiency rotary scroll compressors, operated in single (sizes 1 and 15) and tandem (sizes 18 to 6) per independent circuit for greater efficiency at partial loads. Electronic expansion valve (EXV) allows for precise control through all operating ranges, resulting in higher efficiency and improved reliability. Proven reliability that s built in Thousands of AquaSnap chillers are already in service around the world. This field-proven design is backed by a 12-month warranty that includes the hydronic system. The compressors are maintenance-free and protected by an auto-adaptive control that minimizes compressor wear. Unit sizes 35 and up have two independent refrigerant circuits. Year-round operation is standard, from 2 F ( 29 C) (with optional cooler heater, low ambient control, and wind baffles) to 12 F (5 C). Rotary scroll compressors provide smooth, quiet and reliable operation. All-in-one package AquaSnap chillers provide the most comprehensive chilled water circuit available for any air-cooled chiller. 2 Included is a brazed plate direct expansion cooler that may be remotemounted. The cooler is also completely drainable with factory-installed vents and drains. Electronic thermal-dispersion flow switch is included with the cooler. The switch is factory installed and tested and contains no moving parts for high reliability. Optional integrated hydronics package is more than just a pump, it is an entire chilled water system, including: Single/dual pumps up to 7.5 hp and 12 ft head Regular strainer Cleanout strainer Flow regulator Freeze protection to 2 F ( 29 C) (with freeze protection option) Heaters Required piping Pressure/temperature taps Isolation valves for dual pump systems VFD compatibility The factory-installed and tested hydronics package provides faster, simpler and less expensive installation. Digital scroll compressors are available as a factory-installed option. These allow for incremental unloading with capacity modulation to better match building load when compared to standard scroll compressors. Environmentally sound Carrier s Puron refrigerant (R-41A) enables you to make a responsible decision in the protection of the earth s ozone layer. Puron refrigerant is an HFC refrigerant that does not contain chlorine that is damaging to the ozone layer. Puron refrigerant is unaffected by the Montreal Protocol. Puron refrigerant is a safe, non-toxic*, efficient and environmentally sound refrigerant for the future. Durable construction The 3RAP chillers have a structurally sound base that can be point-loaded, therefore, no perimeter base rail is required. All 3RAP units have weatherized cabinets constructed of heavy-duty galvanized steel with exterior panels painted with corrosion-resistant baked enamel. Inside and outside surfaces are protected to ensure long life and good appearance. The durable, galvanized steel, painted components exceed the requirements of the 5-hour salt spray test per ASTM (American Society for Testing and Materials) B117. ComfortLink TM controls speak your language The ComfortLink controls communicate in plain English, making it as easy as possible to monitor and control each AquaSnap chiller while accurately maintaining fluid temperatures. The large scrolling marquee display acts as a window into the unit s operation, providing easy-to-read information about chiller performance and over 15 diagnostic functions. Carrier 3 Series chillers ComfortLink controls provide features such as chilled water temperature reset, demand limiting, compressor wear minimization and protection, temperature and pressure displays and diagnostic functions. These controls result in higher chiller reliability, simplified training and more productive service calls with correspondingly lower operational and maintenance costs. Carrier s exclusive accessory handheld Navigator display provides convenience and powerful information in the palm of your hand. The Navigator display helps technicians to quickly diagnose problems and even prevent them from occurring. All AquaSnap units are ready to be used with the Carrier Comfort Network (CCN) system. AquaSnap units minimize the impact on your footprint, as well as your bottom line The integrated hydronics and the chilled fluid storage tank s placement under the chiller minimize the footprint, allowing easy installation almost anywhere. Novation heat exchanger technology The Novation heat exchanger design with microchannel (MCHX) condenser coil is a robust, cost effective alternative to traditional coil design. These coils are offered coated or uncoated to match coil protection to site conditions. The Carrier Electronic Catalog (E-Cat) can be used to determine whether or not corrosion protection is recommended for particular applications in coastal/marine environments. * Under ASHRAE Standard , R-41A is classified as an A1 refrigerant.

3 Run Status Service Test Temperatures Pressures Setpoints Inputs Outputs Configuration Time Clock Operating Modes Alarms ENTER Following the input of the requested data, the E-Cat program output will advise the appropriate coil to be used. Other factors described in "Selection Guide: Environmental Corrosion Protection, Novation Heat Exchanger with Microchannel Coil Technology" catalog number must also be considered to determine if corrosion protection is required. Microchannel coils are more robust than other coil types, making them easier to clean without causing damage to the coil. Due to the compact all aluminum design, microchannel coils will reduce average unit operating weight by 25% compared to the previous 3RA units. The streamlined MCHX coil design also reduces refrigerant charge by an average of 6% compared to the previous 3RA units. AEROACOUSTIC FAN vs. PROPELLER FAN MODE Run Status Service Test Temperature Pressures Setpoints Inputs Outputs Configuration Time Clock Operating Modes Alarms Alarm Status ESCAPE ENTER SCROLLING MARQUEE DISPLAY ComfortLink SOUND POWER [db(a)] PENETRATES BUILDING STRUCTURE /3 OCTAVE BAND CENTER FREQUENCY (Hz) AEROACOUSTIC FAN PROPELLER FAN AEROACOUSTIC FAN VS PROPELLER FAN MODE Alarm Status ESC NAVIGATOR DISPLAY MODULE LOW-SOUND AEROACOUSTIC FAN WITH NIGHTTIME LOW SOUND TUBES FINS a3-486 MANIFOLD OPTIONAL HYDRONIC PACKAGE MICROCHANNELS NOVATION HEAT EXCHANGER TECHNOLOGY WITH MICROCHANNEL CONDENSER COILS 3

4 Model number nomenclature AQUASNAP CHILLER MODEL NUMBER DESIGNATION 3RA P 1 6 D 6 3RA Air-Cooled AquaSnap Chiller Refrigerant Type P Puron Packaging/Security Options Std Packaging 4 Security Grilles/Hail Guards Only 8 Skid Only D Skid, Security Grilles/Hail Guards J Skid, Top Crate, Bag N Skid, Top Crate, Bag, Security Grilles/Hail Guards Unit Sizes Controls/Communications Options Std 5 EMM B EMM, GFI Voltage / Electrical Options No Disconnect, No Cooler Heater 1 No Disconnect, Cooler Heater D Non-Fused Disconnect, No Cooler Heater F Non-Fused Disconnect, Cooler Heater Condenser Coil/Low Sound Options 5 MCHX, Value Sound Fan 6 MCHX, E-coat, Value Sound Fan D MCHX, AeroAcoustic Fan F MCHX, E-coat, AeroAcoustic Fan J MCHX, AeroAcoustic Fan, Ultra-Low Sound K MCHX, E-coat, AeroAcoustic Fan, Ultra-Low Sound Revision Level Current Revision Level Ambient/Capacity Control/Interrupt Options Std Comp, Std Interrupt 1 Hot Gas Bypass, Std Interrupt 2 Digital Comp, Std Interrupt 3 Std Comp, High SCCR 4 Hot Gas Bypass, High SCCR 5 Digital Comp, High SCCR 6 Low Ambient, Std Comp, Std Interrupt 7 Low Ambient, Hot Gas Bypass, Std Interrupt 8 Low Ambient, Digital Comp, Std Interrupt 9 Low Ambient, Std Comp, High SCCR B Low Ambient, Hot Gas Bypass, High SCCR C Low Ambient, Digital Comp, High SCCR Hydronic System No Pump 1 Single Pump, 1 Hp 2 Single Pump, 1.5 Hp 3 Single Pump, 2 Hp 4 Single Pump, 3 Hp 5 Single Pump, 5 Hp 6 Single Pump, 5 Hp High Head 7 Single Pump, 7.5 Hp 8 Dual Pump, 1 Hp 9 Dual Pump, 1.5 Hp B Dual Pump, 2 Hp C Dual Pump, 3 Hp D Dual Pump, 5 Hp F Dual Pump, 5 Hp High Head G Dual Pump, 7.5 Hp EMM Energy Management Module GFI Ground Fault Interrupting MCHX Microchannel Heat Exchanger SCCR Short Circuit Current Rating Quality Assurance Certified to ISO 91: 2 Table of contents Page Features/Benefits Model Number Nomenclature AHRI Capacity Ratings Physical Data Options and Accessories ,1 Base Unit Dimensions Accessory Dimensions Selection Procedure Performance Data Typical Piping and Wiring Electrical Data Controls Typical Control Wiring Schematic Application Data Guide Specifications a

5 AHRI* capacity ratings UNIT 3RAP CAPACITY COP Coefficient of Performance EER Energy Efficiency Ratio IPLV Integrated Part Load Value COMPRESSOR POWER INPUT (kw) FAN POWER (kw) TOTAL POWER (kw) FULL LOAD IPLV COOLER FLOW RATE COOLER WATER PRESSURE DROP Tons kw EER COP EER COP GPM L/s Ft wg kpa * Air Conditioning, Heating, and Refrigeration Institute. NOTE: Based on AHRI-55/59 standard rating conditions. Ratings are for standard chillers only. Ratings do not include options. 5

6 Physical data *All units have Victaulic connections, sized for IPS Carbon Steel piping. Flow switch and strainer are standard on all units, with or without hydronic package. ENGLISH UNIT 3RAP OPERATING WEIGHT (lb) MCHX Condenser Coil, No Pump MCHX Condenser Coil, Single Pump MCHX Condenser Coil, Dual Pump REFRIGERANT TYPE R-41A, EXV Controlled System Total Refrigerant Charge (lb) Refrigerant Charge (lb) Ckt A/Ckt B 8.6/ 9.6/ 14.6/ 15.2/ 16.7/ 17.6/ 14.3/ / / / / /17.4 COMPRESSORS Scroll, Hermetic Quantity Speed (Rpm) 35 (Qty, Tons) Ckt A (1) 11 (1) 15 (2) 9 (2) 1 (2) 13 (2) 15 (2) 1 (2) 1 (2) 11 (2) 13 (2) 13 (2) 15 (Qty, Tons) Ckt B (2) 9 (2) 11 (2) 13 (2) 13 (2) 15 (2) 15 Oil Charge (Pt) Ckt A/Ckt B 6.9/ 6.9/ 13.8/ 13.8/ 13.8/ 13.8/ 13.8/ / / / / /13.8 No. Capacity Steps Standard With Hot Gas Bypass Digital Compressor Option Minimum Capacity Step (%) Standard With Hot Gas Bypass Digital Compressor Option Capacity (%) Circuit A Circuit B COOLER Brazed, Direct-Expansion Plate Heat Exchanger Weight (lb) (empty) Net Fluid Volume (gal) Maximum Refrigerant Pressure (psig) Maximum Water-Side Pressure Without Pump(s) (psig) Maximum Water-Side Pressure With Pump(s) (psig) CHILLER WATER CONNECTIONS (in.) Inlet and Outlet, Victualic (IPS Carbon Steel)* / / / / / / 2 Drain (NPT) 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 CONDENSER FANS Standard Low-Sound AeroAcoustic Plastic Type, Axial, Vertical Discharge Type Fan Speed (Rpm) No. Blades...Diameter (in.) No. Fans Total Airflow (Cfm) ,5 17,5 19,4 19,4 29,6 29,5 29,3 3,5 38,8 38,8 Optional Value Sound Type Propeller Type, Axial, Vertical Discharge Fan Speed (Rpm) No. Blades...Diameter (in.) No. Fans Total Airflow (Cfm) 12,6 12,6 23,4 23,4 26, 26, 39,8 39,6 39,3 41, 52,1 52,1 CONDENSER COILS Novation MCHX Aluminum Tube, Aluminum Fin Quantity (Ckt A/Ckt B) 1/ 1/ 1/ 1/ 1/ 1/ 1/1 1/1 1/1 1/1 1/1 1/1 Total Face Area (sq ft) Maximum Refrigerant Pressure (psig) HYDRONIC MODULE (Optional) Pump(s), Strainer with Blowdown Valve, Expansion Tank, Pressure Taps, Drain and Vent Plugs, Flow Switch, and Balance Valve Pump Single or Dual, Centrifugal Monocell Pump(s), 35 Rpm. Dual pumps with check valves and isolation valves. Expansion Tank Volume (gal) Total/Acceptance 4.4/ /1.3 CHASSIS DIMENSIONS (ft - in.) Length Width Height EXV Electronic Expansion Valve MCHX Microchannel Heat Exchanger 6

7 EXV Electronic Expansion Valve MCHX Microchannel Heat Exchanger *All units have Victaulic connections, sized for IPS Carbon Steel piping. Flow switch and strainer are standard on all units, with or without hydronic package. SI UNIT 3RAP OPERATING WEIGHT (kg) MCHX Condenser Coil, No Pump MCHX Condenser Coil, Single Pump MCHX Condenser Coil, Dual Pump REFRIGERANT TYPE R-41A, EXV Controlled System Total Refrigerant Charge (kg) Refrigerant Charge (kg) Ckt A/Ckt B 3.9/ 4.4/ 6.6/ 7.1/ 7.6/ 8./ 6.8/ / / / / /8.1 COMPRESSORS Scroll, Hermetic Quantity Speed (R/s) 58.3 (Qty, kw) Ckt A (1) 38 (1) 53 (2) 32 (2) 35 (2) 46 (2) 53 (2) 35 (2) 35 (2) 38 (2) 46 (2) 46 (2) 53 (Qty, kw) Ckt B (2) 32 (2) 38 (2) 46 (2) 46 (2) 53 (2) 53 Oil Charge (L) Ckt A/Ckt B 3.3/ 3.3/ 6.5/ 6.5/ 6.5/ 6.5/ 6.5/ / / / / /6.5 No. Capacity Steps Standard With Hot Gas Bypass Digital Compressor Option Minimum Capacity Step (%) Standard With Hot Gas Bypass Digital Compressor Option Capacity (%) Circuit A Circuit B COOLER Brazed, Direct-Expansion Plate Heat Exchanger Weight (kg) (empty) Net Fluid Volume (L) Maximum Refrigerant Pressure (kpa) Maximum Water-Side Pressure Without Pump(s) (kpa) Maximum Water-Side Pressure With Pump(s) (kpa) CHILLER WATER CONNECTIONS (in.) Inlet and Outlet, Victualic (IPS Carbon Steel)* / / / / / / 2 Drain (NPT) 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 1 / 2 CONDENSER FANS Standard Low-Sound AeroAcoustic Plastic Type, Axial, Vertical Discharge Type Fan Speed (R/s) No. Blades...Diameter (mm) No. Fans Total Airflow (L/s) , 14, 13,8 14,4 18,3 18,3 Optional Value Sound Type Propeller Type, Axial, Vertical Discharge Fan Speed (R/s) No. Blades...Diameter (mm) No. Fans Total Airflow (L/s) , 11, 12,3 12,3 18,8 18,7 18,5 19,4 24,6 24,6 CONDENSER COILS Novation MCHX Aluminum Tube, Aluminum Fin Quantity (Ckt A/Ckt B) 1/ 1/ 1/ 1/ 1/ 1/ 1/1 1/1 1/1 1/1 1/1 1/1 Total Face Area (sq m) Maximum Refrigerant Pressure (kpa) HYDRONIC MODULE (Optional) Pump(s), Strainer with Blowdown Valve, Expansion Tank, Pressure Taps, Drain and Vent Plugs, Flow Switch, and Balance Valve Pump Single or Dual, Centrifugal Monocell Pump(s), 35 Rpm. Dual pumps with check valves and isolation valves. Expansion Tank Volume (L) Total/Acceptance 17.4/ /39. CHASSIS DIMENSIONS (mm) Length Width Height

8 Physical data (cont) 3RAP SIZE POUNDS A B C D UNIT WEIGHTS STANDARD UNITS SINGLE PUMP UNITS DUAL PUMP UNITS 3RAP SIZE KILOGRAMS Total Weight A B C D Total Weight RAP SIZE POUNDS A B C D 3RAP SIZE KILOGRAMS Total Weight A B C D Total Weight RAP SIZE POUNDS A B C D 3RAP SIZE KILOGRAMS Total Total A B C D Weight Weight RAP1-3 UNITS 3RAP35-6 UNITS B C B C CONTROL BOX SIDE a CONTROL BOX SIDE NOTE: When the accessory storage tank is employed, the value for total weight increases (to be added to the weights shown above) by 1673 pounds (759 kg) on 3RAP1-15, by 2193 pounds (995 kg) on 3RAP18-3, and by 4361 pounds (1978 kg) on 3RAP35-6. Even with the storage tank, all 3RAP chillers require only 4-point support. A D A D 8

9 Options and accessories ITEM FACTORY-INSTALLED OPTION FIELD-INSTALLED ORY Condenser Coil and Sound Options MCHX E-Coat X Low Sound Compressor Blankets X Value Sound Fans X Ultra-Low Sound X Controls/Communication Options BACnet* Translator Control X Chillervisor System Manager III Multi-Unit Control X Energy Management Module (EMM) X X LON (Local Operating Network) Translator Control X Navigator Display X Remote Enhanced Display X Touch Pilot Display X Cooler Options Freeze Protection Cooler Heaters X Remote Cooler Kit X Electrical Options Unit-Mounted Main Disconnect, Non-Fused X GFI Convenience Outlet (115 v) X X High SCCR (Short Circuit Current Rating) X Hydronics Option Hydronic Pump Package X Fluid Storage Tank X Refrigeration Circuit Options Low Ambient Temperature Head Pressure Control X X Hot Gas Bypass (not available on sizes 1 and 15) X X Digital Compressor (not available on size 18) X Security/Packaging Options Security Grilles/Hail Guards X X Vibration Isolation X Wind Baffles X * Sponsored by ASHRAE (American Society of Heating, Refrigeration, and Air Conditioning Engineers). Factory-installed options Novation heat exchanger technology microchannel coil (aluminum fin/aluminum tube) e-coat condenser is available for optimum durability. Novation heat exchangers with microchannel coil technology are offered coated or uncoated to match coil protection to site conditions. The Carrier Electronic Catalog (E-Cat) can be used to determine whether or not corrosion protection is recommended for particular applications in coastal/marine environments. Following the input of the requested data, the E- Cat program output will advise the appropriate coil to be used. Other factors described in "Selection Guide: Environmental Corrosion Protection, Novation Heat Exchanger with Microchannel Coil Technology" catalog number must also be considered to determine if corrosion protection is required. Value sound fans provide a metal, propeller-type fan system which is cost-effective when compared to the lowsound aero-acoustic fan system. This factory-installed fan option is compatible with the Motormaster V option. Ultra-low sound provides a combination of low sound AeroAcoustic fans with sound blankets. Digital compressor control allows incremental unloading for a closer match to building load. This option is not available on the 18 size unit. High short circuit current rating provides a short circuit current rating protection for the unit up to 65, A on 46-v, 38-v, and 28/23-v units or 25, A on 575-v units. Motormaster V low-ambient control provides control of fan motor operation to maintain head pressure at low outdoor ambient temperatures down to 2 F ( 29 C) This option also requires field-installed wind baffles. This option is also available as an accessory. This option is a standard feature on all 3RAP1 and 15 chillers. Non-fused disconnect includes factory-installed nonfused disconnect capability for power and control located at the unit. Energy management module provides energy management capabilities to minimize chiller energy consumption. Several features are provided with this module including leaving fluid temperature reset, cooling set point reset or demand limit control from a 4 to 2 ma signal, 2-point demand limit control (from to 1%) activated by a remote contact closure, and discrete input for Ice Done indication for ice storage system interface. The EMM is also available as an accessory. Freeze protection with cooler heaters provides protection from cooler freeze-up to 2 F ( 29 C). GFI convenience outlet is a factory-installed convenience outlet that includes 4-amp GFI (ground fault interrupter) receptacle with independent fuse protection. Convenience outlet is 115-v female receptacle. This option is also available as an accessory. Hydronic pump package option adds circulating pumps, complete with controls, contactor, VFD compatible motors, and insulated expansion tank. Available in single or dual (lead/lag controlled) cooler pump versions, with 9

10 Options and accessories (cont) total dynamic head external to the chiller from approximately 15 to 12 ft (4.6 to 36.6 m). Hot gas bypass option allows additional capacity reduction for unit operation down below the minimum standard step of capacity. This option is not available on units with the digital compressor option or on the 3RAP1 and 15 units. This option is also available as an accessory on all 3RAP units without digital compressors. Security grilles/hail guards consist of louvered, sheet metal panels which securely fasten to the chiller and provide condenser coil protection against hail and physical damage. This option is also available as an accessory. Field-installed accessories BACnet translator control provides an interface between the unit and a BACnet Local Area Network (LAN, i.e., MS/TP EIA-485). Chillervisor System Manager III multi-unit control accessory allows sequencing of between two and eight chillers in parallel. Pump control is also provided. Energy management module provides energy management capabilities to minimize chiller energy consumption. Several features are provided with this module including leaving fluid temperature reset, cooling set point reset or demand limit control from a 4 to 2 ma signal, 2-point demand limit control (from to 1%) activated by a remote contact closure, and discrete input for Ice Done indication for ice storage system interface. The EMM is also available as an option. LON (local operating network) translator control provides an interface between the unit and a local operating network (i.e., LonWorks* FT-1A ANSI/EIA-79.1). Navigator display module provides a portable, hand held display module for convenient access to unit status, operation, configuration and troubleshooting diagnostics capability. The 4-line, 8-character LCD (liquid crystal display) display provides clear language information in English, French, Spanish or Portuguese. The weatherproof enclosure and industrial grade extension cord make the Navigator module ideally suited for outdoor applications. Magnets located on the back of the module allow attachment of any sheet metal component for hands free operation. Remote enhanced display accessory kit contains a remotely mounted 4-character per line, 16-line display panel for unit diagnostics. Touch Pilot display is a cost-effective, touch-screen, remote-mount device that can be used in lieu of the remote enhanced display. Motormaster V low-ambient control provides control of outdoor-fan motor operation to maintain head pressure at low outdoor ambient temperatures down to 2 F ( 29 C). This accessory also requires field-installed wind baffles. This accessory is also available as a factory-installed option. This accessory is standard on 3RAP1 and 15 units. Chilled water storage tank provides a minimum of 4 gallons per ton loop storage capacity. Includes insulated steel shell tank, Victaulic pipe connections, electric tank heaters, electric cables, vent, drain, and enclosure to allow tank to be installed under the chiller to protect to 2 F ( 29 C). The power supply for the storage tank is obtained from the chiller, so no separate power source is required for this accessory. Vibration isolation consists of field-installed 1 / 4 -in. (.64 cm) neoprene isolator pads (24-in. x 3-in.) (61. cm x 7.6 cm) that reduce vibration transmission from the compressor through the floor and into the conditioned space. Low sound compressor blankets reduce unit sound levels by providing an acoustic blanket on each compressor. Hot gas bypass accessory allows additional capacity reduction for unit operation below the minimum standard step of capacity. This accessory is not available on units which have the digital compressor option. This field-installed accessory is also available as a factory-installed option, but the factory option is not available with digital compressors or unit sizes of 1 or 15. Remote cooler kit provides the additional hardware required to remotely mount the cooler from the unit. There are limits to total separation of the unit to the cooler as well as vertical separation limits, and these are delineated in the accessory installation instructions. Never bury refrigerant piping on these or any other applications. GFI convenience outlet is a field-installed convenience outlet that includes a 4-amp GFI (ground fault interrupter) receptacle with independent fuse protection. The convenience outlet is a 115-v female receptacle. The GFI convenience outlet is also available as a factory-installed option. Security grilles/hail guards consist of louvered, sheet metal panels which securely fasten to the chiller and provide condenser coil protection against hail and physical damage. Security grilles/hail guards are also available as a factory-installed option. Wind baffles facilitate operation down to 2 F ( 29 C) when used in conjunction with low ambient temperature head pressure control. *Registered trademark of Echelon Corporation. 1

11 Base unit dimensions 3RAP1,15 CENTER OF GRAVITY UNIT HEIGHT VICTAULIC CONNECTIONS UNIT X Y H (STANDARD) H (VALUE SOUND) WATER IN/OUT 3RA [467] 37.8 [96] 66.5 [1689] 61. [1549] 2" 3RA [466] [957] 66.5 [1689] 61. [1549] 2" 66.5 [1689.1] 9.52 [ ] 1. [ 25.4 ] SEE NOTE #3 TYP [ ] [ ] 1. [ 25.4 ] SEE NOTE #3 TYP. 36 [914] MIN. 48 [1219] MIN. Y RADIUS 2 [58] CONTROL BOX HINGED [ ] STANDARD CONTROL BOX HINGED 1.5 [ 38.1 ] NOTES: 1. DO NOT CAP OR OTHERWISE OBSTRUCT THE LIQUID LINE TEMPERATURE RELIEF. 2. 7/8 [22.4] PILOT HOLE PROVIDED FOR LOCATING FIELD POWER WIRING. ACTUAL HOLE REQUIRED DEPENDS ON FIELD WIRE SIZING [11.1] HOLE USED FOR MOUNTING UNIT. 4. UNIT MUST HAVE CLEARANCES AS FOLLOWS: TOP - DO NOT RESTRICT. COIL SIDE - 42 [167] FROM SOLID SURFACE. PANEL SIDE - 48 [1219] PER NEC. 5. SEE TABLE COLUMN H; DIMENSION FOR STANDARD FAN OR VALUE SOUND FAN OPTION. 6. CARRIER DOES NOT RECOMMEND INSTALLATION IN A PIT. 7. UNIT CAN BE HANDLED USING THE FORK TRUCK LIFT POCKETS. 8. WATER CONNECTIONS RECESSED 2-3/8 INCHES INSIDE UNIT. 9. DIMENSIONS ARE IN INCHES. DIMENSIONS IN [ ] ARE IN MILLIMETERS AIR FLOW SERVICE FIELD CONTROL WIRING CONNECTIONS WATER-OUT WATER-IN COMPRESSOR FRONT VIEW FORK TRUCK POCKETS PANEL SIDE SEE NOTE #4 COIL AREA CG X TOP VIEW 4.5 [128.7] 7/8 [ 22.4 ] FIELD POWER ENTRY SEE NOTE # [ ] RIGHT SIDE VIEW 42 [167] MIN. SERVICE CLEARANCE BORDER (NOT TO SCALE) AIR FLOW COIL SIDE SEE NOTE #4 36 [914] MIN. H SEE NOTE #5 1.5 [ 38.1 ] VALUE SOUND FAN OPTION (PICTORIALLY) a3-11

12 Base unit dimensions 3RAP18-3 NOTES: 1. DO NOT CAP OR OTHERWISE OBSTRUCT THE LIQUID LINE TEMPERATURE RELIEF. 2. 7/8 [22.4] PILOT HOLE PROVIDED FOR LOCATING FIELD POWER WIRING. ACTUAL HOLE REQUIRED DEPENDS ON FIELD WIRE SIZING [11.1] HOLE USED FOR MOUNTING UNIT. 4. UNIT MUST HAVE CLEARANCES AS FOLLOWS: TOP - DO NOT RESTRICT. COIL SIDE - 42 [167] FROM SOLID SURFACE. PANEL SIDE - 48 [1219] PER NEC. 5. SEE TABLE COLUMN H; DIMENSION FOR STANDARD FAN OR VALUE SOUND FAN OPTION. 6. CARRIER DOES NOT RECOMMEND INSTALLATION IN A PIT. 7. UNIT CAN BE HANDLED USING THE FORK TRUCK LIFT POCKETS. 8. WATER CONNECTIONS RECESSED 2-3/8 INCHES INSIDE UNIT. 9. DIMENSIONS ARE IN INCHES. DIMENSIONS IN [ ] ARE IN MILLIMETERS a

13 Base unit dimensions 3RAP35-6 CENTER OF GRAVITY UNIT HEIGHT VICTAULIC CONNECTIONS X Y (STANDARD) H (VALUE WATER IN/OUT H SOUND) UNIT 3RA [926] 46.8 [117] 66.5 [1689] 61. [1549] 2-1/2" 3RA [921] 44.3 [1118] 66.5 [1689] 61. [1549] 2-1/2" 3RA [921] [1172] 78.5 [1994] 73. [1854] 2-1/2" 3RA5 36. [914] 44. [1118] 78.5 [1994] 73. [1854] 2-1/2" 3RA [927] 44.6 [1133] 78.5 [1994] 73. [1854] 2-1/2" 3RA [927] [1132] 78.5 [1994] 73. [1854] 2-1/2" 48 [1219] MIN. NOTES: 1. DO NOT CAP OR OTHERWISE OBSTRUCT THE LIQUID LINE TEMPERATURE RELIEF. 2. 7/8 [22.4] PILOT HOLE PROVIDED FOR LOCATING FIELD POWER WIRING. ACTUAL HOLE REQUIRED DEPENDS ON FIELD WIRE SIZING [11.1] HOLE USED FOR MOUNTING UNIT. 5. SEE TABLE COLUMN H; DIMENSION FOR STANDARD FAN OR VALUE SOUND FAN OPTION. 6. CARRIER DOES NOT RECOMMEND INSTALLATION IN A PIT. Y 7. UNIT CAN BE HANDLED USING THE FORK TRUCK LIFT POCKETS (MINIMUM OF 6" FORK LENGTH). 1.5 [ 38.1 ] AIR FLOW 8. WATER CONNECTIONS RECESSED 4-1/2 INCHES INSIDE UNIT. DIMENSIONS IN [ ] ARE IN MILLIMETERS COIL AREA 4. UNIT MUST HAVE CLEARANCES AS FOLLOWS: TOP - DO NOT RESTRICT. PANEL SIDE COIL SIDE - 42 [167] FROM SOLID SURFACE. SEE NOTE #4 PANEL SIDE - 48 [1219] PER NEC. COIL SIDE SEE NOTE #4 CG COIL AREA X 9. DIMENSIONS ARE IN INCHES [2247.9] AIR FLOW TOP VIEW 92.5 [2349.5] AIR FLOW 7/8 [22.4] FIELD POWER ENTRY SEE NOTE #2 RIGHT VIEW RADIUS 2 [58] CONTROL BOX HINGED COIL SIDE SEE NOTE #4 FIELD CONTROL WIRING CONTROL BOX CONNECTIONS HINGED H SEE NOTE #5 1.5 [ 38.1 ] CIRCUIT A CIRCUIT B COMPRESSOR COMPRESSOR [ 71.7 ] [ ] 42 [167] MIN. NOTE: 3 OR 4 FANS SERVICE CLEARANCE BORDER (NOT TO SCALE) PANEL SIDE SEE NOTE #4 48 [1219] MIN. 42 [167] MIN. VALUE SOUND FAN OPTION (PICTORIALLY ONLY) WATER-IN WATER-OUT [ 86.2 ] 11.2 [ ] [ ] NOTE # [ ] SEE SEE NOTE #3 TYP. 44. TYP [ ] REAR VIEW FORK TRUCK POCKETS FRONT VIEW a

14 Accessory dimensions ORY STORAGE TANK FOR UNIT SIZES "[63.5] VICTAULIC WATER INLET/OUTLET 1' 1/32" [ 36 ] 1' 11-31/64" [ 597 ] CENTER OF GRAVITY 2.5"[63.5] VICTAULIC WATER INLET/OUTLET 3" [ 76.2 ] 1' 1/32" [ 36 ] MOUNTING HOLES, FOUR CORNERS (TYP) 2' 8-3/4" [ 832 ] 1' 5-13/32" [ 442 ] 1' 5-13/32" [ 442 ].88"[22.35] KNOCKOUT FOR POWER TO CONTROL BOX CONTROL BOX END.395/.45 (TYP) MOUNTING HOLES, MIDDLE EACH SIDE 1-1/2" [ 38.1 ] CENTER OF GRAVITY CONTROL BOX END 5' 8-1/8" [ 173 ] TANK TANK TANK TANK C.B 3' 1-63/64" [ 1193 ] TANK 2' 47/64" [ 628 ] a TANK TANK TANK TANK 14

15 1' 1/64" [ 35 ] 1' 1/32" [ 36 ] 1' 5-13/32" [ 442 ] TANK TANK 1' 5-13/32" [ 442 ] TANK TANK 2.5"[63.5] VICTAULIC WATER INLET/OUTLET ORY STORAGE TANK FOR UNIT SIZES ' 11-17/32" [ 598 ] CENTER OF GRAVITY 3' 8" [ 1118 ] CENTER OF GRAVITY.395/.45 (TYP) MOUNTING HOLES, MIDDLE EACH SIDE 3" [ 76.2 ] MOUNTING HOLES, FOUR CORNERS (TYP) 7' 5-7/8" [ 2283 ] CONTROL BOX END 1-1/2" [ 38.1 ] 2.5"[63.5] VICTAULIC WATER INLET/OUTLET TANK TANK TANK CONTROL BOX END 2' 47/64" [ 628 ].88" (22.35) KNOCKOUT FOR POWER TO THE CONTROL BOX TANK TANK TANK C.B 3' 1-63/64" [ 1193 ] a

16 Accessory dimensions (cont) ORY STORAGE TANK FOR UNIT SIZES /.45 (TYP) MOUNTING HOLES, MIDDLE EACH SIDE 1' 1/64" [ 35 ] 1' 1/32" [ 36 ] 1' 5-13/32" [ 442 ] 3" [ 76.2 ] MOUNTING HOLES, FOUR CORNERS (TYP) TANK 1' 5-13/32" [ 442 ] 1-1/2" [ 38.1 ].88" (22.35) KNOCKOUT FOR POWER TO THE CONTROL BOX 3' 7-63/64" [ 1117 ] CONTROL BOX END 4' 1-23/64" [ 1254 ] CENTER OF GRAVITY MOUNTING HOLES 3' 7-63/64" [ 1117 ] TANK TANK TANK TANK MOUNTING HOLES 2.5"[63.5] VICTAULIC WATER INLET/OUTLET.88" (22.35) KNOCKOUT FOR POWER TO THE CONTROL BOX CONTROL BOX END TANK TANK 3' 8" [ 1118 ] CENTER OF GRAVITY 7' 5-7/8" [ 2283 ] TANK TANK TANK TANK 2' 47/64" [ 628 ] C.B C.B TANK TANK TANK CONTROL BOX END 8' 2-3/4" [ 258 ] a

17 Selection procedure Carrier s electronic catalog chiller selection program provides quick, easy selection of Carrier chillers. The program considers specific temperature, fluid, flow requirements, system pressure drop (for proper pump selection, when required), as well as other factors, such as fouling and altitude correction. To select a 3RAP chiller, including optional pump package when required, use the NACO Packaged Chiller Builder Program. Performance data HEAT EXCHANGER PRESSURE DROP 3RAP1-3 (ENGLISH) DROP ( ) WAT TER PRESSURE GPM a RAP1 4 3RAP2 2 3RAP15 5 3RAP25 3 3RAP18 6 3RAP3 17

18 Performance data (cont) HEAT EXCHANGER PRESSURE DROP 3RAP35-6 (ENGLISH) & 12 4 WATER PRESSURE DR ROP ( ) a GPM 7 3RAP35 1 3RAP5 8 3RAP4 11 3RAP55 9 3RAP RAP6 HEAT EXCHANGER PRESSURE DROP 3RAP1-3 (SI) WATE ER PRESSURE DROP (Kpa) LITERS/SECOND a RAP1 4 3RAP2 2 3RAP15 5 3RAP25 3 3RAP18 6 3RAP3 18

19 HEAT EXCHANGER PRESSURE DROP 3RAP35-6 (SI) & WAT TER PRESSURE DROP (Kpa) LITERS/SECOND a RAP35 1 3RAP5 8 3RAP4 11 3RAP55 9 3RAP RAP6 UNIT PRESSURE DROP NO HYDRONIC PACKAGE 3RAP1-3 (ENGLISH) WAT TER PRESSURE DROP ( ) GPM 1 3RAP1 4 3RAP2 a RAP15 5 3RAP25 3 3RAP18 6 3RAP3 19

20 Performance data (cont) UNIT PRESSURE DROP NO HYDRONIC PACKAGE 3RAP35-6 (ENGLISH) & WAT TER PRESSURE DROP ( ) GPM 7 3RAP35 1 3RAP5 a RAP4 11 3RAP55 9 3RAP RAP6 UNIT PRESSURE DROP NO HYDRONIC PACKAGE 3RAP1-3 (SI) WATE ER PRESSURE DROP (Kpa) LITERS/SECOND a RAP1 4 3RAP2 2 3RAP15 5 3RAP25 3 3RAP18 6 3RAP3 2

21 UNIT PRESSURE DROP NO HYDRONIC PACKAGE 3RAP35-6 (SI) & ER PRESSURE DROP (Kpa) WATE LITERS/SECOND 7 3RAP35 1 3RAP5 a RAP4 11 3RAP55 9 3RAP RAP6 UNIT PRESSURE DROP SINGLE PUMP HYDRONIC PACKAGE 3RAP1-3 (ENGLISH) WATER PRESSURE DR ROP ( ) GPM 1 3RAP1 4 3RAP2 a RAP15 5 3RAP25 3 3RAP18 6 3RAP3 21

22 Performance data (cont) UNIT PRESSURE DROP SINGLE PUMP HYDRONIC PACKAGE 3RAP35-6 (ENGLISH) & 12 OP ( ) WATER PRESSURE DR GPM a RAP35 1 3RAP5 8 3RAP4 11 3RAP55 9 3RAP RAP6 UNIT PRESSURE DROP SINGLE PUMP HYDRONIC PACKAGE 3RAP1-3 (SI) PRESSURE DRO OP (Kpa) WATER LITERS/SECOND 1 3RAP1 4 3RAP2 a RAP15 5 3RAP25 3 3RAP18 6 3RAP3 22

23 UNIT PRESSURE DROP SINGLE PUMP HYDRONIC PACKAGE 3RAP35-6 (SI) & 12 PRESSURE DRO OP (Kpa) WATER P LITERS/SECOND a RAP35 1 3RAP5 8 3RAP4 11 3RAP55 9 3RAP RAP6 UNIT PRESSURE DROP DUAL PUMP HYDRONIC PACKAGE 3RAP1-3 (ENGLISH) WATER PRESSURE DR ROP ( ) GPM 1 3RAP1 4 3RAP2 a RAP15 5 3RAP25 3 3RAP18 6 3RAP3 23

24 Performance data (cont) UNIT PRESSURE DROP DUAL PUMP HYDRONIC PACKAGE 3RAP35-6 (ENGLISH) & 12 WATER PRESSURE DR ROP ( ) GPM a RAP35 1 3RAP5 8 3RAP4 11 3RAP55 9 3RAP RAP6 UNIT PRESSURE DROP DUAL PUMP HYDRONIC PACKAGE 3RAP1-3 (SI) WATER PRESSURE DRO OP (Kpa) LITERS/SECOND a RAP1 4 3RAP2 2 3RAP15 5 3RAP25 3 3RAP18 6 3RAP3 24

25 UNIT PRESSURE DROP DUAL PUMP HYDRONIC PACKAGE 3RAP35-6 (SI) & 12 PRESSURE DRO OP (Kpa) WATER P LITERS/SECOND a RAP35 1 3RAP5 8 3RAP4 11 3RAP55 9 3RAP RAP6 25

26 Performance data (cont) PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 1 Hp AND DUAL PUMP 1 Hp /4AAB 3.94" 6 TOTAL DYNAMIC HEAD (FT) EFFY % GPM Effy..9 BHP GPM BHP NPSHr (FT) GPM EFFY Efficiency NPSHr Net Pump Suction Head Required a

27 PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 1.5 Hp AND DUAL PUMP 1.5 Hp /4AAB 4.25" TOTAL DYNAMIC HEAD (FT) GPM EFFY % Effy. BHP BHP GPM NPSHr (FT) GPM EFFY Efficiency NPSHr Net Pump Suction Head Required a

28 Performance data (cont) PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 2 Hp AND DUAL PUMP 2 Hp /4AAB 4.75" 1 TOTAL DYNAMIC HEAD (FT) GPM EFFY % Effy. Effy. BHP BHP GPM NPSHr (FT) GPM EFFY Efficiency NPSHr Net Pump Suction Head Required a

29 PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 3 Hp AND DUAL PUMP 3 Hp /4AAB 4.375" 7 TOTAL DYNAMIC HEAD (FT) GPM Effy. 3 EFFY % 5 BHP BHP GPM NPSHr (FT) 2 1 EFFY Efficiency NPSHr Net Pump Suction Head Required GPM a

30 Performance data (cont) PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 5 Hp LOW HEAD AND DUAL PUMP 5 Hp LOW HEAD /2AAB 4.63" TRIM 11 TOTAL DYNAMIC HEAD (FT) GPM Effy EFFY FY % 5 BHP BHP GPM 3 NPSHr (FT) 2 1 EFFY Efficiency NPSHr Net Pump Suction Head Required GPM 3

31 PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 5 Hp HIGH HEAD AND DUAL PUMP 5 Hp HIGH HEAD SIZES /4AC 5.75" TRIM 14 TOTAL AL DYNAMIC C HEAD (FT)) a3-542 GPM Effy. Effy BHP BHP P EFFY Y% a GPM a NPSHr SHr (FT) GPM EFFY Efficiency NPSHr Net Pump Suction Head Required 31

32 Performance data (cont) PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 5 Hp HIGH HEAD AND DUAL PUMP 5 Hp HIGH HEAD SIZES /2AC 5.25" TRIM 1 TOTAL TAL DYNAMIC HEAD (FT) GPM 6 EFFY % Effy. BHP BHP GPM NPSHr (FT) EFFY Efficiency NPSHr Net Pump Suction Head Required GPM 32

33 PUMP CURVE FOR HYDRONIC PACKAGE SINGLE PUMP 7.5 Hp AND DUAL PUMP 7.5 Hp /2AC 6" TRIM 15 TOTAL DYNAMIC HEAD (FT) GPM 8 7 Effy EFFY % 6 5 BHP BHP GPM NPSHr (FT) GPM EFFY Efficiency NPSHr Net Pump Suction Head Required 33

34 Performance data (cont) STORAGE TANK PRESSURE DROP CURVES 1. a PRESSURE DROP (ft wg) RAP35-6 3RAP ORY TANK FLOW RATE (gpm) 1. a RAP35-6 PRESSURE DROP (kpa) RAP ORY TANK FLOW RATE (L/s) 34

35 Typical piping and wiring 3RAP UNITS WITHOUT HYDRONIC PACKAGE (SIZE 3 SHOWN) AIR FLOW CONTROL WIRING FIELD POWER SUPPLY TO EXPANSION TANK GATE VALVE VIBRATION ELIMINATOR VALVE PRESSURE GAGE FLOW PUMP SHUT OFF VALVES HEAT TAPE INSULATION IS RECOMMENDED ON ALL EXPOSED PIPING IF AMBIENT TEMPERATURE <32 F ( C) AND NO ANTIFREEZE SOLUTION IS IN SYSTEM Airflow Through Condenser Power Wiring Chilled Water Piping NOTES: 1. Chiller must be installed level to within 1 / 8 in. per foot (1.4 mm per meter) to maintain proper compressor oil return and hydraulics. 2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are for a quick overview of system and are not in accordance with recognized standards. 3. All wiring must comply with applicable local and national codes. 4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating, Refrigerating, and Air Conditioning Engineers) handbook for details. a RAP UNITS WITH HYDRONIC PACKAGE (SIZE 3 SHOWN) AIR FLOW CONTROL WIRING FIELD POWER SUPPLY GATE VALVE FLOW NOTE 5 VIBRATION ELIMINATOR HEAT TAPE INSULATION IS RECOMMENDED ON ALL EXPOSED PIPING IF AMBIENT TEMPERATURE <32 F ( C) AND NO ANTIFREEZE SOLUTION IS IN SYSTEM NOTES: 1. Chiller must be installed level to within 1 / 8 in. per foot (1.4 mm per meter) to maintain proper compressor oil return and hydraulics. 2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are for a quick overview of system and are not in accordance with recognized standards. 3. All wiring must comply with applicable local and national codes. 4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating, Refrigerating, and Air Conditioning Engineers) handbook for details. 5. Air separator required as close to chiller as possible (except primary/secondary systems). Airflow Through Condenser Power Wiring Chilled Water Piping a

36 Typical piping and wiring (cont) 3RAP UNITS WITHOUT HYDRONIC PACKAGE (SIZE 6 SHOWN) FIELD POWER SUPPLY TO EXPANSION TANK VIBRATION ELIMINATOR GATE VALVE VALVE PRESSURE GAGE FLOW SHUT OFF VALVES PUMP GATE VALVE VIBRATION ELIMINATOR FLOW Airflow Through Condenser HEAT TAPE INSULATION IS RECOMMENDED ON ALL EXPOSED PIPING IF AMBIENT TEMPERATURE <32 F ( C) AND NO ANTIFREEZE SOLUTION IS IN SYSTEM NOTES: 1. Chiller must be installed level to within 1 / 8 in. per foot (1.4 mm per meter) to maintain proper compressor oil return and hydraulics. 2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are for a quick overview of system and are not in accordance with recognized standards. 3. All wiring must comply with applicable local and national codes. 4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating, Refrigerating, and Air Conditioning Engineers) handbook for details. Power Wiring Chilled Water Piping a RAP UNITS WITH HYDRONIC PACKAGE (SIZE 6 SHOWN) FIELD POWER SUPPLY VIBRATION ELIMINATOR FLOW GATE VALVE Airflow Through Condenser VIBRATION ELIMINATOR Power Wiring NOTE 5 HEAT TAPE INSULATION IS RECOMMENDED ON ALL EXPOSED PIPING IF AMBIENT TEMPERATURE <32 F ( C) AND NO ANTIFREEZE SOLUTION IS IN SYSTEM Chilled Water Piping NOTES: 1. Chiller must be installed level to within 1 / 8 in. per foot (1.4 mm per meter) to maintain proper compressor oil return and hydraulics. 2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are for a quick overview of system and are not in accordance with recognized standards. 3. All wiring must comply with applicable local and national codes. 4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating, a3-487 Refrigerating, and Air Conditioning Engineers) handbook for details. 5. Air separator required as close to chiller as possible (except primary/secondary systems). 36

37 TYPICAL PIPING DIAGRAM ON 3RAP UNITS WITH HYDRONIC PACKAGE Strainer/Blow-Down Valve 2 Expansion Tank 3 Pump 4 Electric Heater 5 Air Vent Connection Port 6 Pressure/Temperature Access Port 7 Heat Exchanger 8 Flow Switch 9 Balance Valve/Drain Plug 1 Pressure Relief 11 Isolation Valves 12 Flex Connections 13 Pressure Reducing/Fill Valve 14 Air Separator and Vent --- Factory Supplied a

Product Data. Features/Benefits. AquaForce 30XA080-501 Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

Product Data. Features/Benefits. AquaForce 30XA080-501 Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw) Product Data AquaForce 080-501 Air-Cooled Liquid Chillers 80 to 500 Nominal Tons (265 to 1740 Nominal kw) a30-4024 Well exceeds ASHRAE 90.1 Standards. AquaForce chillers were designed from the ground up

More information

DATA CENTER SOLUTIONS. For More Information: (866) 787-3271 Sales@PTSdcs.com. Technical Data

DATA CENTER SOLUTIONS. For More Information: (866) 787-3271 Sales@PTSdcs.com. Technical Data DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com Technical Data Contents Overview................................................ 1 Scalable Solution for Critical Environments...................

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT 48/50E-4SB 48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT GAS HEAT ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

AFHX Guide Specifications

AFHX Guide Specifications AFHX Guide Specifications Part 1: General 1.01 Work Included A. Provide a complete Air Cooled Packaged Chiller utilizing rotary screw compressors suitable for outdoor installation and be controlled by

More information

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

MUELLER FALLING FILM CHILLERS

MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

Product Data. Split System Cooling 22-1904-1F-EN. March 2015

Product Data. Split System Cooling 22-1904-1F-EN. March 2015 Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:

More information

SECTION 23 64 10 AIR COOLED WATER CHILLERS

SECTION 23 64 10 AIR COOLED WATER CHILLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Chiller package B. Charge of refrigerant and oil C. Controls and control connections D. Chilled water connections E. Starters F. Electrical power connections 1.2

More information

Local Dealer: www.cebrands.com

Local Dealer: www.cebrands.com Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication

More information

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 D SERIES MODULAR AIR-COOLED SCROLL CHILLER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 CONTENTS 1.MODELS LIST... 3 2.NOMENCLATURE... 3 3.FEATURES... 3 4.PRODUCT

More information

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................

More information

Defining Quality. Building Comfort. Heating and Cooling Coils

Defining Quality. Building Comfort. Heating and Cooling Coils Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product Data 4TTB3018-060 1½ 5 Tons PUB. NO. 22-1843-14 Features and Benefits Efficiency up to 13.25 SEER All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess cabinet, easy

More information

Are these noise cancelling devices needed to make your chiller quiet??

Are these noise cancelling devices needed to make your chiller quiet?? Are these noise cancelling devices needed to make your chiller quiet?? Not on this chiller! Some sound barriers should never be broken. Government authorities recommend that exposure to loud noise over

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

catalog Single Package Vertical Air Conditioners and Heat Pumps

catalog Single Package Vertical Air Conditioners and Heat Pumps catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter Chiller/Heat pumps 30AWH Reversible Monobloc inverter C O M P A C T, R E L I A B L E A N D E F F I C I E N T Reversible Compact, reliable and efficient 2 The new AquaSnap PLUS chillers and reversible heat

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

AIR-COOLED CONDENSERS Technical Guide

AIR-COOLED CONDENSERS Technical Guide BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

DESIGN STANDARDS SECTION 23 60 00

DESIGN STANDARDS SECTION 23 60 00 PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Liebert DS Thermal Management Unit

Liebert DS Thermal Management Unit Liebert DS Thermal Management Unit System Design Manual - 28-105kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL Economizer Coil, Dual-Cool DX with Secondary

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

YCAA-B AIR COOLED LIQUID CHILLER

YCAA-B AIR COOLED LIQUID CHILLER YCAA-B AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 46 kw to 152 kw York YCAA-B twin refrigerant circuit air cooled liquid chillers are a compact design suitable for chilled water or

More information

Air-Cooled Condensers

Air-Cooled Condensers Air-Cooled Condensers 20 to 120 Tons April 2001 Introduction Air-Cooled Condensers Built for Every Need Trane has the right condenser...if you are designing a new system or replacing an existing air-cooled

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

ice 3 FLUID TO FLUID HEAT PUMP

ice 3 FLUID TO FLUID HEAT PUMP ice 3 FLUID TO FLUID HEAT PUMP SUBMITTAL DATA (888) 530-7713 P O Box 5, Wentworth, H 03282 Rev.3 (5-30-14) ice 3, IC-2040 Fluid-to-Fluid R-410a Heat Pump Engineering Guide Specifications General otes:

More information

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060 4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER

INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER INSTALLATION & OPERATION MANUAL MODULAR AIR COOLED CHILLER Model: MAC160/210A CONTENTS MAC00912-A4 Part No.: M08019301021 1. Features page2 2. Nomenclature page3 3. Specifications page5 4. Performance

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET.

HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. HEATING AND COOLING SYSTEMS THAT FIT COMFORTABLY WITHIN YOUR BUDGET. AFFORDABLE SOLUTIONS FROM AMERISTAR. We know that heating and cooling systems can be a major investment for homeowners. Our goal is

More information

Sigma Frequency Control

Sigma Frequency Control Sigma Frequency Control SFC Series 18 to 515 Capacities: from 22 to 3069 cfm Pressures: from 80 to 217 psig Variable Speed Technology from Kaeser Most compressed air systems have varying loads and it is

More information

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information