Troubleshooting the RC Controller
|
|
|
- Godwin James
- 9 years ago
- Views:
Transcription
1 Technical Newsletter Special Issue Published by Rain Bird Sales, Inc. Turf Products Fall 1999 IN THIS ISSUE: RC Controller Troubleshooting 5000 Series Rotor Rain Bird Contest Online Irrigation Answers Hour Dial Auto/Off Switch Fuse Day Dial Station Dial Troubleshooting the RC Controller Learn to Identify and Correct the Most Common Electromechanical Controller Problems When an irrigation system fails, the controller is usually the first component to be blamed. However, in reality, 30-50% of controllers returned actually have no defects. With a few troubleshooting tips and techniques, you can easily save yourself and your customer valuable time and money. Rain Bird s RC Controllers are designed with basic functions that minimize maintenance and provide solutions as simple as the design itself. All you need is a basic knowledge of AC voltage and a voltohmmeter. Covering the Basics Here are a few basic checkpoints for troubleshooting your RC Series controller. Hour Dial Shaft Reduction Gear Shaft Timing Motor Resistor Microswitch-Hour Wafer Switch Station Dial Shaft Pivot Shaft Auto/Off Switch Timing Motor Microswitch-Day Microswitch- Station Dial Rapid Advance Motor Fuse Holder Check the programming. This includes the start time (time of day that irrigation should begin), run time (length of irrigation for each station) and days on (actual days the irrigation will operate). If any part of the programming is missing, the controller will not activate some or all of the valves. Check the Auto/Off switch. Make sure the controller is in the AUTOMATIC or ON position. Determine whether the system has either rain or moisture sensors. A sensor cuts continued on next page
2 [ ]continued Editorial by Rod Waller Can you troubleshoot a Rain Bird RC- Series Controller? How skilled are you at repair? We devoted this issue of the Technical Newsletter to electromechanical controllers to challenge and inform you. Plus, if you are a Rain Bird Authorized Service Center (ASC), Level 2 or higher, you are asked to repair these units to maintain your ASC status. As a reminder, here is an excerpt from the 1999 ASC Program Guide: Level 2 - Perform repairs on-site or within your inter-branch system on 75% of all electromechanical controllers. Levels 3 & 4 Perform repairs on-site or within your inter-branch system, rather than sending them to outside vendors, on 90% of all electromechanical and solid-state controllers. If you are having trouble meeting these requirements, please let us know how we can help. Your success is important to Rain Bird. An RC-Series Controller can be tested in five minutes at the counter. Fifty percent of the problems can be caught right there. For example, if the controller tests OK, the trouble may be in the field wiring or primary power supply. Identifying this quickly saves the contractor time in the field. Testing may yield some important clues, enabling a more rapid field diagnosis. By the way, Rain Bird receives numerous inquiries regarding Year 2000 compliance for RC-Series controllers. I m not kidding. Call it a hunch, but I think they ll work just fine. Rod Waller Authorized Service Center Manager [email protected] Rain Bird Sales, Inc South Bonney Ave. Tucson, AZ from front power off to the valves. The controller will run as programmed, but no watering will occur. Check for the correct time/day. The controller should always show the correct time and day as long as it is connected to the primary power source. If the time or day is not correct, check the primary power, transformer, circuit breaker or fuse. Check the primary power. Verify that 117 volt VAC power is on and correctly connected. If power is above 129 or below 105, contact a certified electrician. Check the transformer. The output should be between 24 and 28 VAC. If not, replace it. Timing Motor (above) Resistor (below) Check the circuit breaker or fuse. If it is blown, it s most likely caused by a field wiring short. The electromechani- cal controller will stop on the station that caused the problem. Reset the controller in rest position, replace the fuse or circuit breaker. Manually advance to station #1 and allow it to run for one minute. If it operates correctly, continue to Station #2 and the other stations, repeating the process until the fuse blows. Disconnect the wire that operates that valve. Be sure to test all stations because there could be more than one problem. Check the clock motor (or timing motor). The clock motor must operate continuously whether the controller is on or off, in order to keep proper time; therefore, this motor may fail after an extended time. Verify that the motor is receiving proper voltage. Then set the hour to the correct time and wait one hour. If the hour dial has not moved, replace the motor. Change the resistor. Each RC Controller has a 43 ohm, 5-watt resistor, wired inseries to the timing motor. The purpose of this resistor is to limit current and reduce heat in the timing motor. Without it, the motor will not last long. When changing the timing motor, you must change the resistor also. (Part #651137) Test the gears and clutches. The RC-Series electromechanical controllers all use gears to transfer the rotation of the clock motor to the hour and station timing. If you suspect a problem, try to very gently rotate the station dial and hour dial on the face plate in the opposite direction from the direction that the arrows show. If it rotates backwards without much force, the gear and clutch assembly is stripped and it s time to replace it. DO NOT EXERT EXCESSIVE FORCE FOR THIS TEST. Check the advance motor (or rapid advance motor). This motor operates only when the controller is changing stations or returning to rest position. To determine whether or not the motor is receiving proper voltage, check the leads with a volt-ohmmeter for 24 VAC. By turning all stations off and manually rotating the station dial to the OFF or rest position, you can apply power to the rapid advance motor.
3 HOUR DIAL MICROSWITCH DAY DIAL MICROSWITCH HOUR DIAL DAY DIAL WHT/BLU BC6 COM WAFER SWITCH FRONT NEUTRAL AND VALVE COMMON 24 VAC TO STATION MASTER VALVE HOT/24 VAC B4 REST POSITION 4 GRAY 8 BC3 3 GRAY WAFER SWITCH BACK WHT/ WHT/ J P TO VALVES STATION WHT/ MASTER VALVE WHT/ WHT WHT/ WHT/ WHT WHT WHT/GRN VALVE COMMON WIRE NUT E2 WHT/GRY E3 WIRE NUT AUTO/OFF WHT/ STATION DIAL MICROSWITCH BLK F1 FUSE WHT/BLU B2 BLK OR REST STATION DIAL M1 B1 24 VAC LINE VOLTAGE TIMING MOTOR B5 43 ohm/5w RESISTOR C TRANSFORMER WHT/ BLK OR M2 BLK OR RAPID ADVANCE MOTOR If you do not have voltage at the leads, the micro switch may have failed. Check the micro switch (see section below for testing micro switches). Another good test is to apply 24 volt AC directly from another source. If the motor does not turn, it needs to be replaced. If it does turn, check the primary power and transformer. Test the micro switches. Your controller s micro switches are small switches that, when activated, instruct the controller to perform a certain function. If a micro switch fails or is out of adjustment, the controller will not perform as programmed. Your controller relies on a day micro switch, hour micro switch and timing dial micro switch. To determine whether or not a micro switch has failed, turn off primary power to the controller and conduct a resistance test using a volt-ohmmeter. Resistance should be below 2 ohms when closed and infinite when open. Remember, the button of the micro switch should not be depressed until the program pin is locked into position to activate the switch. To adjust the micro switches, see below. Adjusting micro switches in your RC Controller To adjust RC Controller hour/day dial micro switches: 1. Loosen the two screws holding the switch bracket to the front panel. 2. Pull out all but four equally spaced day or hour pins on each dial. 3. Set each switch bracket so the four pins remaining barely touch the surface of the switch breaker arm before coming into contact with the ramp. 4. Tighten both mounting screws
4 while holding the switch bracket in place to prevent shifting. 5. Pull out the remaining four pins on each dial. All retracted pins should clear the switch bracket actuator arm. To adjust RC Controller station timing micro switches: For course adjustment - loosen the righthand mounting screw, rotate the station dial to rest position, and turn the adjusting screw clockwise until the back of the metal switch actuating arm is 1/32-inch from the switch body. 1/32" For fine adjustment: 1. Adjust each station knob to the minimum timing mark. (The pointer will not always fall on the center at this mark.) 2. Turn the controller to the AUTO position. 3. Move the station dial clockwise from rest position and allow it to stop at Station 1. After the dial stops at Station 1, immediately rotate it just past Station 1. It should now advance and stop at Station 2. Repeat this for all stations. Now, turn the adjustment screw clockwise in one quarter-turn increments until the dial fails to stop at a station. When that happens, turn the adjusting screw back a quarter-turn counterclockwise. Make sure that the dial stops at every station and that the gap between the actuating arm and the switch is at least 1/64-inch. Check the wafer switches. The wafer switch is the distribution point for the valve voltage. As the center hub turns with the station dial, the wafer switch is connected to the station dial shaft. As it turns, a tab on the wafer switch touches the station contact point and powers the valve. Problems occur when dirt accumulates on the tabs or contacts. You can carefully clean the wafer switch hub with the eraser of a pencil, being careful not to bend the contacts. To clean the back side of the switch, remove the mounting screws and lift the wafer switch off its shaft. The wafer switch can also be damaged by lightning. Burn marks would indicate this type of damage. Notice on the front wafer switch that the tab is in contact with Station #1. [ ] Put On Your Thinking Cap... Put Your Knowledge of Rain Bird RC Controllers to the Test and Earn Your Free Rain Bird Cap! Try your hand at correctly answering the following questions. If you are one of the first 100 to submit the right answers, you will receive a FREE Rain Bird hat. Choose one of the following answers for each. Circle your answers on the form below and submit it to Rain Bird by fax or by [email protected]. The correct answers will be published in the next issue. Allow 4-6 weeks for delivery of your hat. 1. The 24-hour clock on the RC controllers allows you to select how many different start times per day? a b c. any number 2. With 12-station RC controllers, you can set the watering times from. a minutes in one-minute increments b minutes in two-minute increments. c minutes in one-minute increments. 3. The RC-C uses a to protect the system against short circuits. a. fuse b. circuit breaker c. quick release plug 4. The RC controllers can be started manually using the. a. station dial b. MODE switch c. day dial Name: Company: Address: City: State: Zip: Phone: FAX: address:
5 Quick Reference To Most Frequently Asked Questions Here are solutions to specific problems you re most likely to encounter in the field: Problem Clock stopped. Hour dial not turning. Cause Circuit breaker tripped (RC-C and RC-AB models only) Fuse blown (RC-Bi models only) Time of day is not correct. Solution Push reset. If controller stops again, check field wiring for possible short circuits. Replace fuse. If fuse blows again, check field wiring for possible short circuit. No power to controller Check transformer power. If voltage is zero, check line voltage and check primary power. If zero, check the building s circuit breaker. Faulty timing motor To check, reset the time on the hour dial and check back in one hour. Faulty resistor Or try a resistance test. The test should show about 300 ohms for a good clock motor without the resister on it. With resistor in place, add another 43 ohms. Check the resistor - it should read 43 ohms. If not, replace it with Part # Clock stops between Station 4 and REST on any RC-4 model. There is a factory built-in 20-minute delay on four-station controllers. None - this is a standard feature. Controller recycles immediately without stopping in the rest position. Insufficient cycle time was allowed. Adjust total run time for more than 20 minutes Day and hour dials function correctly, but cycle will not start correctly. Off-auto switch is in wrong position. Move switch to the AUTO or ON position. Pins on day and hour dial not programmed correctly. Re-program as necessary. Day and hour micro switches out of adjustment See section on micro switch adjustments above. Defective day or hour micro switches. Test with volt-ohmmeter and replace as needed. The RC-AB Series controllers have a three-position day switch. When the switch is all the way out, it is off. When the switch is half-way in, it operates program A or the upper panel stations only. When the switch is all the way in, it operates both the A and B programs (upper and lower panel stations). To correct, ensure the switch is pushed in to the appropriate position. The lower panel must begin operation before midnight on the watering day if the following day is scheduled as an off day. Another option is to install a 6 a.m. change-over hour dial. Ensure start time is programmed so the lower panel cycle begins before midnight. Stations controlled by the top panel (on the RC-1860AB or RC-2360AB) operate correctly during an automatic cycle schedule, but the set of stations controlled by the lower panel do not water. (It takes about 20 minutes for the hour dial pin to sweep past the micro switch. This allows the hour dial start pin to move off the micro switch. The micro switch must be open or it will allow another start. In other words, if the total time on all stations is less than 20 minutes, the controller will go past the final station, advance to rest and immediately initiate another cycle start.)
6 [ Put Performance Over the Top With New 5000 Series Rotors ]Have You Connected With Rain Bird? Durability, performance and the convenience of arc adjustment from the top. These are a few of the benefits you ll find in the rugged, mid-range 5000 Series Rotor, the newest addition to Rain Bird s residential and light commercial line. The unique 5000 Series Rotor offers easy adjustment to the arc from the top with no special tools -only a flat-head screwdriver. The arc can be adjusted from 40 to 360 degrees. This versatile rotor also offers the convenience of reversing full- or part-circle operation in one product, said product manager J. R Bergantino. A non-reversing, full-circle-only model is also available. The rotor uses a proven water-lubricated, gear-driven design and offers a unique reinforced flow path for additional side-load strength, explained Bergantino. It also provides special O-ring seals for better performance in gritty water. The new 5000 Series Rotor is available in four, six or 12-inch models with a TREE of six low angle nozzles with a 10% trajectory angle, three Radius + nozzles for a throw of 29 to 50 feet, and six standard Rain Curtain nozzles with a trajectory of 25% and a throw from 23 to 40 feet. Customers can also choose either a 2.0 or 3.0 GPM pre-installed Rain Curtain nozzle. A pressure-activated, multi-function wiper seal blocks debris from the rotor s internal parts to ensure pop-up and retraction. In addition, a heavy-duty retract spring ensures positive pop-down. A durable rubber cover is standard. The rotor also offers fast forward arc check and optional Seal-A-Matic (SAM) check valves to prevent low head drainage in elevations up to seven feet. Backed by Rain Bird s five-year warranty, the new 5000 Series Rotor delivers reliable performance from the top down. Online Irrigation Answers on the World Wide Web The latest Rain Bird products and changes. Technical tips. Answers to some of the most frequently asked irrigation questions. You ll find these technical resources and more at your fingertips at Rain Bird s site on the World Wide Web. Here are a few of the things you can do online when you click on Turf Irrigation at Access the entire catalog. This is one of the most important benefits of the Web site for distributors, said Rain Bird s webmaster, Rebecca Ryan Hunter. Rather than tearing out or copying catalog pages for customers, you can print the actual pages you need directly from the Web site, complete with product information, including performance charts. Information on the Web site is actually even more accurate and up-to-date than that in the printed catalog because it is continuously updated. Find entire product manuals. Most of the printed manual that is usually distributed to customers is available on the Web. This reduces the distributor s workload to handle other issues more efficiently. Download SpecDraw drawings. These detailed Auto-Cad drawings of Rain Bird can be downloaded instantly from the Web site. Select Site Reports and Point of Connection newsletters. Print only the newsletters you need to significantly cut down on paperwork. The choice is yours Print information, save it as text files, or download images. Site maps and other features make it easy to browse. You ll find all the instructions you need for traveling throughout the site and using its information online. Even though Rain Bird does not sell any turf products directly from the site, it serves as a great technical and information resource with 24 hours a day for you and your customers. Use the feedback form found at the site to share your ideas with us. It s a great way for distributors to let us know what they re thinking and how we can improve the site for them, explained Rebecca Hunter. The Rain Bird site is constantly changing and growing, said Rebecca Hunter, who encourages distributors to check back frequently for updated information, the latest charts and more. The Rain Bird Web site is a technical resource that is constantly evolving based on your feedback to better service your needs.
5000 Series Rotors 5000, Plus, PRS, SAM
Tech Spec 00 Series Rotors 00, Plus, PRS, SAM Built from top to bottom with the contractor in mind, the Rain Bird 00 Series product line is the durable, reliable rotor for residential and commercial applications.
IMPACT SPRINKLER TROUBLESHOOTING GUIDE
RAIN USE AND OPERATION BIRD IMPACT SPRINKLER TROUBLESHOOTING GUIDE The diagrams below depict typical Rain Bird sprinklers with all available controls. Your particular model may have only some of these
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. Tankless Electric (RTE) Troubleshooting
Sequence of Operations 1 Power supply and field wiring block 2 Energy Cut Off (ECO) 3 Water flow plunger and cold inlet 4 Magnetic flow switch 5 Water temperature thermistor 6 Control panel and circuit
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
IMPACT SPRINKLER TROUBLESHOOTING GUIDE
RAIN USE AND OPERATION BIRD IMPACT SPRINKLER TROUBLESHOOTING GUIDE The diagrams below depict typical Rain Bird sprinklers with all available controls. Your particular model may have only some of these
Multi-Pitch Pitching Machine USER MANUAL
Multi-Pitch Pitching Machine USER MANUAL TABLE OF CONTENTS Thank you for purchasing the Cimarron Multi-Pitch Pitching Machine. The Cimarron Multi-Pitch Pitching Machine is a high performance pitching machine
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
Field-Tested and Fixed in Five!
Technical Newsletter Special Issue Published by Rain Bird Sales, Inc. Turf Products Late Spring 2000 IN THIS ISSUE: Controller Troubleshooting ESP Controller Improvements RASTER Testing Field-Tested and
SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT
Troubleshooting Error Codes During operation when an error occurs, the board will use the LEDs to indicate where the problem exists. For motor specific faults, the green LED will blink once for Motor 1,
High kw Electric Tankless Water Heater Troubleshooting Guide
Technical Service Bulletin High kw Electric Tankless Water Heater Troubleshooting Guide Models: WH17, WH27, WH36 AE115, AE125, (FD108 and higher) DANGER: ELECTRIC SHOCK ELECTRICITY IS EXTREMELY DANGEROUS.
Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.
www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing
Model 2300DR Installation Guide
Model 2300DR Installation Guide POWER ACCESS CORPORATION P.O. BOX 1050 170 MAIN STREET NEW HARTFORD, CT 06057 800-344-0088 WEBSITE: www.power-access.com EMAIL: [email protected] 1 STANDARD PARTS
ELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
Arctic Leash Instruction Manual Alaskan Products Company LLC.
Retractable Cord Reel for Engine Block Heaters Arctic Leash Instruction Manual Alaskan Products Company LLC. INSTALLATION INSTRUCTIONS This instruction manual is a reference guide for installing and operating
TOYOTA ELECTRONIC TRANSMISSION CHECKS & DIAGNOSIS
Checks and Adjustments The transmission requires regular maintenance intervals if it is to continue to operate without failure. As we discussed in previous sections, transmission fluid loses certain properties
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE
SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
VEHICLE SPEED CONTROL SYSTEM
PL VEHICLE SPEED CONTROL SYSTEM 8H - 1 VEHICLE SPEED CONTROL SYSTEM TABLE OF CONTENTS page DESCRIPTION AND SPEED CONTROL SYSTEM...1 SPEED CONTROL SERVO-PCM OUTPUT....2 SPEED CONTROL SWITCHES PCM INPUT...2
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español
For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Vancouver Model Name 21321, 21328 Model No. Type A Models Owner s Guide and Installation
INSTRUCTION BOOK FOR. Large Cosmopolitan Electrol
INSTRUCTION BOOK FOR Large Cosmopolitan Electrol Important Safety Instructions When using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps
A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps Troubleshooting Submersible Pumps Fuse overload or circuit breaker trips when motor is started 1. Incorrect line voltage. Check the line
Windshield Wiper Motors
Windshield Wiper Motors Originally posted by Dan Masters, [email protected] Also see http://www.advanceautowire.com/ WIPER OPERATION: There are three major components to a wiper motor: Motor Rotary to linear
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS
SERVICE BULLETIN No.1103
SERVICE BULLETIN No.1103 Circulate to listed addressees COACH MODEL BULLETIN TYPE MANUAL & SECTION PARTS BOOK REVISION : T 2100 and C2000 Series : Service Information : Maintenance Manual: Chapter 3 Drive
CETAC Z-Drive Assembly
CETAC Z-Drive Assembly Replacement Guide Manual Part Number 610144 Rev 1, 2012 CETAC Technologies, Printed in USA Overview This guide describes the necessary steps to replace the Z-drive assembly on your
LED MOTION ACTIVATED FLOOD LIGHT
Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español
Your Simple Guide to Battery. www.firstalertpro.com. Replacement. Customer Care: 1-800-852-0086. www.firstalertpro.
Previous Menu Your Simple Guide to Battery www.firstalertpro.com Replacement p e t s ts ep -by Customer Care: 1-800-852-0086 FA/1565 9/00 www.firstalertpro.com Table of Contents: page Introduction...............................
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator
JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
Odyssey of the Mind Technology Fair. Simple Electronics
Simple Electronics 1. Terms volts, amps, ohms, watts, positive, negative, AC, DC 2. Matching voltages a. Series vs. parallel 3. Battery capacity 4. Simple electronic circuit light bulb 5. Chose the right
No Rainfall Data is Collected
No Rainfall Data is Collected There are a number of issues that can cause the system to not collect rainfall data, from clogged collectors to hardware failure or improper part replacement. The most common
User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:
User Manual Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included: 1: Display Console 1: Control Box 2: Encoder (Wires attached) (Not Shown) 1: 5v Power Supply
Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series
Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series Operating Instructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT THE RISK OF ELECTRIC
Essential Electrical Concepts
Essential Electrical Concepts Introduction Modern vehicles incorporate many electrical and electronic components and systems: Audio Lights Navigation Engine control Transmission control Braking and traction
LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS
OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE-100B HE-100BW HE-112 HE-112W HE-117 HE-117W HE-117-2B OWNER'S MANUAL FLOOD LAMPS (BULBS) Your
SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series
SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series 2400/2500 Series 3000 Series 3100 Series Simplex 5000 Series
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND
Honeywell Electronic Ignition Troubleshooting Tech Tip April 2007 The Honeywell S8610H Intermittent Pilot Module provides the ignition sequencing, pilot spark, pilot flame monitoring, Pilot Valve (PV)
SE-1200-EI. Operation & Parts Manual
SE-1200-EI Operation & Parts Manual SE 1200 EI OWNERS MANUAL Table of Contents 1. Installation guide 2. Set-up instructions 3. Operation instructions 4. Cleaning 5. Troubleshooting 6. Parts manual 7. Electrical
Class 5 to 7 Truck and Bus Hydraulic Brake System
Class 5 to 7 Truck and Bus Hydraulic Brake System Diagnostic Guide 1st Edition * 5+0 Important Service tes The information in this publication was current at the time of printing. The information presented
TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12
Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: [email protected] Cleaveland/Price Type TP-C2 Motor Operator
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
Operator Manual 100 Series Coffee Grinders
Operator Manual 100 Series Coffee Grinders Models 100 and 190SS Model 100 Model 190SS Specifications...2 Safety Information...2 Installation...3 Operation...3 Table of Contents Cleaning & Maintenance...6
Wiper Motor Marinco 2.5. Installation Instructions
Wiper Motor Marinco 2.5 Installation Instructions Wiper Motor Marinco-2.5 The Marinco 2.5 Wiper Motor Offers the Following Features: Fully sealed base and housing which allows installation in outdoor wet
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225
MOTION-ACTIVATED SECURITY LIGHT ASSEMBLY &OPERATING INSTRUCTIONS Solar Motion-Activated Security Light - 80 LED Lights Model #40225 IMPORTANT: READ ALL INSTRUCTIONS CAREFULLY BEFORE USE ABOUT YOUR SOLAR
ETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A
Operation Manual 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A Endoscopy Support Services, Inc. Croton River Executive Park Route 22, Bldg. 3 Brewster, NY 10509
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html TECHNICAL SERVICE DEPARTMENT Effective October 2007, we transitioned to the White Rodgers (Intelli-Vent TM )Thermostat Control for
GUTTER MACHINE CONTROLS STANDARD
GUTTER MACHINE CONTROLS STANDARD Note: determine what type of control package is installed on the machine. --more-- All operators should familiarize themselves with the appropriate controls prior to any
DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear
DIAMOND Gear Company, LTD. an ERIKS Company Installation, Maintenance, & Operation Manual Declutchable Worm Gear 2016 DECLUTCHABLE WORM GEAR INSTRUCTIONS This is an instructional manual which provides
D I G I T A L C L A M
T h e M A X X P r e s s D I G I T A L C L A M O P E R A T O R S M A N U A L 6 x0 x5 5 x5 Folie & Papper Sweden AB Box 90 00 9 Göteborg Telefon 03-9 00 80 Fax 03-9 00 89 www.foliepapper.se Safety Instructions
SECURITY LIGHT. motion-activated. Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights
motion-activated SECURITY LIGHT Model #: 40225, 40226 Assembly & operating instructions Solar Motion-Activated Security Light - 80 LED Lights Important: Read all instructions carefully before use About
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html
http://waterheatertimer.org/how-to-troubleshoot-gas-water-heater.html APPLY POWER TO APPLIANCE FIELD WIRING CORRECT? DPLAY ERROR CODE 1 OR 2 Intelli-Vent TM Sequence of Operation REQUEST FOR HEAT PRESENT?
Installation and Operation Guide PD4600 Series Converter Replacement
Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
Ceramic Glass Electric Galley Ranges
Ceramic Glass Electric Galley Ranges OWNER S MANUAL Models # 65335, 65336, 75331, 75332 Read all instructions and warnings before operating. Force 10 Manufacturing Corporation Unit A 19169 21 st Ave Surrey,
FTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm
002 - CONNECTING THE PRINTER Now that you have an idea what 3D printing entails, we can continue and connect the printer to your computer. First make sure you have a computer with a decent amount of RAM
INSTRUCTION MANUAL (WINDOW WIPER)
INSTRUCTION MANUAL (WINDOW WIPER) SUBJECT CONTENTS PAGE 1. GENERAL 2 2. CONTRUCTION 2 2-1. STRAIGHT LINE TYPE WINDOW WIPER 2 2-2. CONTROL BOX 2 2-3. SPARE PARTS 2 3. MECHANISM AND OPERATION 2 3-1. STRAIGHT
1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
Model 53603. Owner s Manual. Español - P. 19 Français - P. 39
Model 53603 Owner s Manual Español - P. 19 Français - P. 39 Table of Contents I. Introduction............................ 1 Sample Watering Plan.......................... 1 II. Installation...........................
Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings
Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy savings Sensitive 180º view passive infrared motion detector keeps lights on only when rooms are in use. No ON switch so lights
Windshield Wiper System
Volkswagen Golf 5 - Windshield Wiper System Volkswagen Technical Site: http://volkswagen.msk.ru http://vwts.info Page 1 / 15 92-1 Windshield Wiper System General information The windshield wiper system
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev C IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
Original Assembly Guide
TCT Multipurpose Single Bevel Sliding Compound Mitre Saw Original Assembly Guide Read instructions before assembling this tool. Table of Contents GB Assembly Guide Read instructions before assembling this
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN 78 95. MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER
INTRODUCTION Thank you for purchasing a WATERBOY pumping system. We set the standard for quality and economy in solar pumping. The WATERBOY range incorporates the best solar pump technologies that were
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with the National
BB -508L/509L INSTALLATION MANUAL LATTICE BOOM CRANES. Greer Company Crane Systems. Greer Company
BB -508L/509L ANTI TWO-BLOCK ALARM SYSTEM LATTICE BOOM CRANES INSTALLATION MANUAL BB TM -508/509 Anti Two-Block System Lattice 1 of 14 PN W250015 01/21/01 BB -508L/509L ANTI TWO-BLOCK ALARM SYSTEM INSTALLATION
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Operating Instructions
Operating Instructions Series L 000 Cord Reels Model Numbers: L 000 L 0 0 L 0 B L 0 X L 00 L A X L 0 L 0 0 L 00 L 0 L 0 B L 0 0 X L 00 L 0 A L 0 X IMPORTANT Read this manual carefully before installing,
POWER TRIM 5 F AUTO TRIM AND AUTO TRIM
POWER TRIM 5 F 22217 AUTO TRIM AND AUTO TRIM Table of Contents Page Auto Trim System........................ 5F-1 Description........................... 5F-1 Auto Trim Operation...................... 5F-2
7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions
Instructions Instructions The Parts in this section of the manual are listed by Item Number, Part Number, Description and Quantity. The Item Numbers are in a circle with an arrow pointing to the specific
Combo heat press machine. Instruction
Combo heat press machine Instruction Pressing Technique Voltage: 220V/110V Maximum power: 1800W Temperature: 0-250 Time: 0-3minutes Introduction 1:Clamp&handle 2:Pressure Knot 3:Control console 4:Fuse
Instruction Manual EAGLE 500/550 EAGLE 700/750 EAGLE 900/950 EAGLE 1100/1150
Instruction Manual EAGLE 500/550 EAGLE 700/750 EAGLE 900/950 EAGLE 1100/1150 THANK YOU FOR CHOOSING RAIN BIRD We are aware that you have a choice, and we are happy you chose Rain Bird. The Eagle Rotor
Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification
OWNER S MANUAL Model MH1230 Important Safety Instructions Assembly Instructions Parts and Hardware Identification Pallet Jack CAUTION: Read, understand and follow ALL instructions before using this product
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
MODEL E-AF. Drain Cleaning Machine. Operator s Manual
MODEL E-AF Drain Cleaning Machine Operator s Manual!!!! FOR YOUR SAFETY Before you operate or maintenance this equipment, READ this manual carefully and completely! Purchase Date: Serial Number: ELECTRIC
Operating Precautions: User configuration options:
A Division of Lippert Components, Inc. PNP BED-LIFT USERS MANUAL Product Usage: This product is designed and intended ONLY to be used as a Bed-Lift mechanism. Any other use of this system will void any
Retrofit Instructions Installing a Sport Heated Steering Wheel - Leather, Multifunction BMW X5, E53, 2001 2006
Retrofit Instructions Installing a Sport Heated Steering Wheel - Leather, Multifunction BMW X5, E53, 2001 2006 Disclaimer: This set of instructions is simply a guide on how I installed my own heated steering
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
i ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
Safety, Operation and Maintenance Manual with Parts List
Safety, Operation and Maintenance Manual with Parts List 20-Gallon Wet/Dry Vac Important Information and Safety Instructions PLEASE READ BEFORE USE! # 961130020 9/10-Rev 1 20-Gallon Wet/Dray Vac TABLE
TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table
New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex
ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.
ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging
INSTALLATION AND OPERATING INSTRUCTIONS
ddcwp_manual_gb_revisions.ai 10/23/06 Page 1 Date: Station 1 2 3 4 5 6 7 8 CUSTOM WATERING PLAN 3 Program Controller Description Program A Program B Program C Duration Duration Duration DDC WP Series Waterproof
Solstice/Sky Water Pump Replacement
Solstice/Sky Water Pump Replacement The water pump on the Solstice/Sky is starting to need replacement on some vehicles. This guide will help in replacing the water pump while the engine is still in the
