1 C A T A L O G U E une avance dans l air du temps *A step forward into the air of our time

2 The Group Founded in 958 near Lyon, France, TECHNIBEL joined airconditioning, heating and air treatment leader, the AER.FI group (based near Milan, Italy), in 99. Production facilities Group products are manufactured in Italy, France, Japan and China. The facilities in Gallarate (Italy) and Reyrieux (France) cover a total surface of 8,000 sq.m. approximately 50,000 sq.m. of which is roofed. To satisfy our customers and minimise delivery deadlines, production can be transferred between the two sites to maximise production capacity. Flexibility is a group strength. Research and Development The Engineering and Design departments and the Test Laboratories in France and Italy work closely together to develop new products using the most advanced technologies that fully meet market expectations. Technibel has recently invested in sophisticated new testing units, which allow computerised recording and processing of product performance data in all operating conditions. This investment is helping to ensure a high level of quality and functional suitability as soon as the product is launched. Quality In december 005, Technibel obtained the replacement of the certification according to the standard EN ISO 900 : 000. Meet the requirement of our final customer and daily perform ourselves are two of our main objectives in the company. EN ISO 900 Certificat n R40A Ozone layer protection Almost 95% of all the products presented in this catalogue from mobile airconditioners to water chillers and heat pumps up to 7 kw use R 40 A cooling fluid. (production in Gallarate) Technibel will provide the corresponding attestations on request 4

3 Certifications and standards The CE marking, which was created as part of European legislation, permits the free movement of manufactured products throughout the EEC, and constitutes a guarantee of product safety and installation. CE marking The product ranges presented in this catalogue have the CE label. This indicates that they comply with: the Electromagnetic Compatibility directive 89/336 CEE, amended by 9/3/CEE and 93/68/CEE the Low Voltage directive 73/3/CEE, amended by 93/68/CEE. the Pressure Equipment directive no. 97/3/CE. The directive on Energy Consumption of Air Conditioners for Domestic Use no. 9/75/CEE00/3/CE This directive concerns direct expansion devices with a cooling capacity under kw; it takes effect from January 005. The directive is designed to provide a very clear classification of devices according to their energy efficiency (from "A = economical device" to "G = uneconomical device"), with the purpose of economizing the electricity consumed in the European Community, and generally to give the consumer more information (on noise levels, etc.). For the Technibel units concerned: a) the sales documentation (rectoverso type) intended for the end user will include all the information required by the directive b) the corresponding indicator labels will be supplied for units exhibited in sales outlets open to enduser customers. Products in this catalogue currently meet two new European directives, according to generally accepted interpretations: Directive WEEE/DEEE (00/96/EC) regulates domestic electrical waste recycling Directive RO (00/95/EC) regulates the removal of some harmful substances from electrical and electronic components. Direct Expansion Range EUROVENT NOMINAL CONDITIONS The technical characteristics of the monosplit and multisplit models are given in accordance with the following nominal conditions (except where otherwise indicated in the tables): Cooling T outdoor air T indoor air 7 C (DB) / 9 C (WB) 35 C (DB) Heating T outdoor air T outdoor air 0 C (DB) 7 C (DB) / 6 C (WB) u n e a v a n c e d a n s l a i r d u t e m p s 5

4 Noise level : sound power and sound pressure It goes without saying that air conditioning has to meet human requirements in matters of thermal comfort, health and acoustic comfort. All customers are looking for the quietest machine; the difficulty is how to compare the "noise levels" provided by the makers. The noise level of a machine is defined by two measurements: Sound power 40 db Pain threshold Sound pressure an objective measure made in accordance with standards in force under nominal operating conditions. This is a characteristic of the machine. The comparison of the sound power for equivalent machines (similar in type and power) is strongly recommended before taking any decision. As the number of decibels obtained does not correspond to the noise experienced when the apparatus is installed in a living environment (flat, office, shop, etc.), each manufacturer use to calculate and to provide a sound pressure value. KPAF 4 CHG 8, PHR 8 CWX8, CAF 94 CWX3 MCAF 74 MCW KPSW 3 00 db 90 db 80 db 70 db 60 db 50 db 40 db 30 db 0 db 0 db 0 db Pneumatic drill Techno music Company canteen Dense traffic Background noise in an average office, radio Conversation Background noise in a living room Bedroom Light wind in trees is calculated on the basis of sound power according to the following formula: Lp = Lw + 0 x log [(Q/4 x π x d) + (4/R)]. This is not a characteristic of the machine, but the result of a calculation. The calculation formula takes into account the capacity of the elements situated around the machine to reflect and absorb sound. Sound pressure is an estimated value. It does not therefore commit Technibel to any specific final result. Furthermore, results will differ according to the distance between the apparatus and the point of measurement. Technibel indicates sound pressure at the following distances: at m for indoor units (Direct Expansion range and Water range); many manufacturers give this measurement at 4 m, thus obtaining a lower sound pressure value at 4 m in unenclosed space for outdoor units at 0 m in unenclosed space for chilled water units. Example of an indoor wallmounted unit MCAF 74 C or R : sound power at low speed (LS) = 39 dba sound pressure at low speed at m = 30 dba Below is a comparative scale of sound pressures (according to figures provided by the department of the Secretary of State for the Environment) 6

5 0

6 > Split units for lowtemperature premises 8 C COOLING CSCVLL 5 > The CSCVLL range of split airconditioners is designed for lowtemperature air conditioning, with temperatures between and 8 C, for premises such as wine cellars, florists storerooms, bin storage units, etc. Maintaining a temperature of between and 8 C helps to limit the growth of harmful bacteria, therefore ensuring better standards of hygiene. The interior unit can be mounted vertically against a wall as standard, or ceiling mounted in order to keep maximum floor space free. Automatic remote control K 60 D 05 Z ACCESSORIES Remote hygrothermostat K 60 D 047 Z Manual remote control ACCESSORIES TO BE ORDERED IMPERATIVELY Remote control or K 60 D 05 Z or Remote hygrothermostat K 60 D 047 Z: In this case, the electric heater accessory is obligatory. A humidity thermostat can be used to control an air humidifier (not supplied). Type Model Code Manual remote control RAB 30 All Automatic remote control All K 60 D 05 Z Remote hygrothermostat All K 60 D 047 Z kw 30//50 TAV 5 K 60 C Z Electrical heating kw 30//50 TAV K 60 C 84 Z 3 kw 30//50 TAV K 60 C 843 Z TAV 5 K 60 N 03 Z Side deflexion grille TAV 0 K 60 N 04 Z TAV 30 K 60 N 05 Z TAV 40 K 60 N 08 Z Ceiling support for indoor unit TAV 5 K 60 U 004 Z TAV K 60 U 00 Z TAV 5 K 60 U 0 Z Wall support for indoor unit TAV 0 K 60 U 03 Z TAV 30 K 60 U 04 Z TAV 40 K 60 U 08 Z Wall support for outdoor unit GRV K 70 U 00 T

7 > Split units for lowtemperature premises 8 C Set CSCV 5 LL 5 CSCV 0 LL 5 CSCV 30 LL 5 CSCV 40 LL 5/7 Indoor unit 30//50 Outdoor unit 30//50 or 400/3N/50 Cooling capacity (kw) Input power (kw) Heating capacity of electric heater (kw) EER LS Internal air flow (m 3 /sm 3 /h) MS Running current cooling** (A) Refrigerant type Ø refrigerant connections FLARE (inches) External Ø of condensate drain pipe (mm) Max. distance between units (m) Max. height difference between units (m) Sound power indoors LS/MS/ level (dba) condenser Sound pressure at m indoors LS/MS/ level (dba) 4 m from condenser Indoor unit dimensions (height x width x depth) (mm) Outdoor unit dimensions (height x width x depth) (mm) Weight I.U. / O.U. (kg) Nominal conditions T indoor air T outdoor air C (DB) / 9 C (WB) 35 C (DB) TAV 5 L 8 G GRV 7 L 5 T /4 3/ / 50 / / 4 / x840x35 540x700x65 8 / 34 TAV 0 L 8 G GRV 9 L 5 T.6.05 / /4 3/ / 59 / / 5 / x950x35 540x700x65 37 / 36 TAV 30 L 8 G GRV L 5 T / /4 / / 60 / / 5 / x40x35 540x700x65 4 / 37 TAV 40 L 8 G GRV 80 L 5 T GRV 80 L 7 T / /4.* /4 / / 6 / / 54 / x60x35 630x830x / 5 * phase/ 3 phase **for heating mode, see the installed heating capacity MONOSPLITS ON/OFF R 407 A OPERATING LIMITS COOLING maximum T indoor air 3 C (DB) / 3 C (WB) T outdoor air 43 C (DB) minimum T indoor air C (DB )/ 9 C (WB) T outdoor air 5 C (DB) Manual remote control Electromechanical thermostat with 3 fan speeds Manual selection of operating mode (heat/cool) For units with " pipe coil" only or " pipe coil + electric heater" or "4 pipe coil" Main characteristics Supply voltage : 30Vac 50/60 Hz Fonctions : On/Off + 3speed fan selector Manual selection of operating mode Setpoint adjustment range : 8/30 C (possibility of mechanical limitation by jumpers on the knob) Permanent or slaved ventilation Contact breakers : A inductive Differential : K maxi Electrical connections at screw terminal block Operating temperature : 0/+50 C Relative humidity < 95% Casing insulation : cl II IP 30 Colour : white RAL 9003 Automatic remote control K60D05Z Electronic thermostat with 3 fan speeds Automatic selection of operating mode (heat/cool) Main characteristics Supply voltage : 30Vac 50/60Hz Functions : On/Off + 3speed fan selector Supplied with builtin air temperature sensor Input remote air temperature sensor (as accessories : uncased sensor for air intake K60D08Z, or cased sensor K60D033Z) Setpoint adjustment range : 5/30 C Factory set to + 7 C/+ 30 C (possibility of mechanical limitation by jumpers on the knob) Contact breakers : 3 A inductive for ventilation 0 A resistive, 6 A inductive for Heat or Cool mode Differential Neutral zone : adjustable 0,7 to 7,5 K Electrical connections at screw terminal block Operating temperature : 0/+50 C Relative humidity < 95% Casing insulation : cl II IP 30 Colour : white RAL 900 u n e a v a n c e d a n s l a i r d u t e m p s 53

8 Water range Water chillers Air/Water with hydraulic module > CHG 8 to 7 kw 8 > CHGV to 78 kw 30 > CMHGV 0 to 40 kw 3 Heat Pumps Air/Water with hydraulic module > PHRT 9 to 8 kw 34 > PHRV 4 to 76 kw 36 > PMHRV 95 to 63 kw 38 WATER CHILLERS AND HEAT PUMPS u n e a v a n c e d a n s l a i r d u t e m p s 7

9 > Water chillers with hydraulic equipment R 40 A AIR / WATER CHG FROM 8 TO 7 kw 0 59 CHG 8/7 CHG 8 CHG /5/7 > Refrigerant fluid : R 40 A The best COP on the market The lowest noise levels on the market More compact units 90 x 340 x 735 mm 90 x 340 x 35 mm High quality components Scroll compressor with sound insulation high performance heat exchanger with fins for the R 40 A axial fan motor heat exchanger with AISI 36 stainless steel plates and heat insulation, etc. Hydraulic equipment Functions of the control system : Elimination of the buffer receiver vessel Adjustment of the condensation pressure Automatic control of the circulating pump (antifreeze and antiseize function) Defrosting adjusted according to the outdoor temperature Alarm management by means of event logging External communication via a serial interface (Protocol Modbus) Other advantages : Improved access to components Keypad/display fitted to the front panel Dividing bulkhead between the fan and the machinery compartment Option of removing the control panel for a wider opening Stringent manufacturing inspections : Helium waterproof test, dielectrical and electrical test, hydraulic test, Standard equipment Water flow switch Proportional head pressure control LP switch HP switch Hydraulic filter (connectable) Hydraulic equipment 8

10 > Water chillers with hydraulic equipment Model Code 30//50 400/3N/50 Cooling capacity (kw) Input power (kw) EER Water flow (m 3 /h) Available head pump (kpa) Refrigerant type Number of refrigeration circuits Number of compressors Expansion tank volume (l) Ø of male water connector Sound power level (dba) Sound pressure level* (dba) Length (mm) Depth (mm) Height (mm) Weight (kg) CHG 8 CHG CHG 5 CHG 7 CHG 085 F CHG 087 F R 40 A 3/ R 40 A R 40 A R 40 A *Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 0 m. Nominal conditions T outdoor air + 35 C T water inlet + C T water outlet + 7 C OPERATING LIMITS (pure water) CHG 7 F CHG 57 F CHG 77 F T outdoor air CHG 8 and 5 T outdoor air CHG T outdoor air CHG 7 0 C (DB) / +43 C (DB) 7 C (DB) / +43 C (DB) 4 C (DB) / +43 C (DB) T water outlet maximum + 0 C T water outlet minimum + 5 C ACCESSORIES Type Models Code Set of flexible length m Ø 3/4 CHG water pipes length m Ø CHG /5/ Insulated 50 liters tank CHG 8//5/ Single startup kit CHG Remote control keyboard and display CHG 8//5/ RS 485 communication interface MOBDUS protocol CHG 8//5/ (please consult us for protocol details) PRECAUTIONS FOR INSTALLATION 50 X Y Dimensions in mm CHG 8 CHG 5 7 X Y WATER CHILLERS AND HEAT PUMPS u n e a v a n c e d a n s l a i r d u t e m p s 9

11 > Water chillers with hydraulic equipment AIR / WATER CHGV FROM TO 78 kw 0 6 CHGV / CHGV 50/80 > CHGV to 40 CHGV 50 to 80 New range from 47 to 78 kw Improved performance : Increase in the available hydraulic pressure More compact units High quality components Scroll compressor with sound insulation air heat exchanger: copper tubes with aluminium fins axial fan motor with variable speed control heat exchanger with AISI 36L stainless steel plates and heat insulation,... Hydraulic equipment Functions of the control system: Elimination of the buffer receiver vessel Adjustment of the condensation pressure Automatic control of the circulating pump (antifreeze and antiseize function) Defrosting adjusted according to the outdoor temperature Alarm management by means of event logging External communication via a serial interface (Protocol Modbus) Output for controlling an additional electrical device Simplified operation and maintenance: Keypad/display fitted to the front panel Access panel to the electrical cabinet Access panels at the side and at the front Provision for HP and LP connections Holes to accommodate slings Standard equipment ON/OFF main switch proportional head pressure control HP and LP switches water flow switch phase sequence tester hydraulic equipment (circulating pump with control valve, expansion tank, safety valve, air vent, water manometer, ) hydraulic filter (connectable) condenser coil protection grille 30

12 > Water chillers with hydraulic equipment Model CHGV CHGV 5 CHGV 3 CHGV 40 Code 400/3N/50 CHG 7 V CHG 57 V CHG 37 V CHG 407 V Cooling capacity (kw) Input power (kw) EER Water flow (m 3 /h) Available head pump (kpa) Refrigerant type Number of refrigeration circuits Number of compressors Expansion tank volume (l) Ø of male water connector "/4 "/4 "/4 "/4 Sound power level (dba) Sound pressure level* (dba) Length (mm) Depth (mm) Height (mm) Weight (kg) Temporary information Model CHGV 50 CHGV 64 CHGV 7 CHGV 80 Code 400/3N/50 CHG 507 V CHG 647 V CHG 77 V CHG 807 V Cooling capacity (kw) Input power (kw) EER Water flow (m 3 /h) Available head pump (kpa Tank volume (I) Refrigerant type Number of refrigeration circuits Number of compressors Expansion tank volume (l) Ø of male water connector "/ "/ "/ "/ Sound power level (dba) LS () 85 () Sound pressure level* (dba) LS () 57 () Length (mm) Depth (mm) Height (mm) Weight (kg) *Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 0 m. Nominal conditions T outdoor air + 35 C T water inlet + C T water outlet + 7 C OPERATING LIMITS T inlet air to condenser Standard with head pressure control: 0 C / + 45 C Pure water outlet T: + 4 C / + 0 C Consult Technibel for any special climatic conditions which differ significantly from the nominal conditions ACCESSORIES Type Models Code Remote control keyboard and display CHGV to RS 485 communication interface MOBDUS protocol CHGV to Switch HP and LP CHGV to CHGV CHGV 50 to x CHGV x Set of flexible length m Ø /4 CHGV to water pipe length.5 m Ø / CHGV 50 to Set of 4 antivibration pads 5 mm thick CHGV to liters Tank CHGV to CHGV 50 to WATER CHILLERS AND HEAT PUMPS u n e a v a n c e d a n s l a i r d u t e m p s 3

13 > Water chillers with builtin hydraulic module AIR / WATER CMHGV FROM 0 TO 40 kw 0 CMHGV 0/40 > The very complete standard equipment enables safe, simple and quick installation. The phase sequence controller ensures the safety of your SCROLL compressor in the event of phase reversal. These compact water chillers can be easily integrated, both on a roof or on the ground ; needed space around the units is reduced Hydraulic equipment : insulated buffer tank water pump with control valves expansion tank safety valve air vent, ) Quality components : Scroll compressor with sound insulation Air heat exchanger : copper tubes with aluminium fins Direct drive axial fans Stainless steel brazed plate heat exchanger protected against freezing and underflows Switchbox Automatic switching of the compressor running order ensures that they age at exactly the same rate Low noise thanks to the use of compressors fitted with soundproofing and antivibration pads and fans with twospeed rotation Maintenance made easy : All accessing and connecting is carried out at the front All panels can be removed Two completely independent refrigerant circuits Electronic controller : easy to see setpoints, adjustments, parameters and alarms three hierarchical access levels (user, installer, maintenance engineer) alarms. Standard equipment ON/OFF main switch proportional head pressure control HP and LP switches water flow switch phase sequence tester hydraulic equipment hydraulic filter (connectable) condenser coil protection grille 3

14 > Water chillers with builtin hydraulic module Model CMHGV 0 CMHGV 4 CMHGV 40 Code 400/3/50 Cooling capacity (kw) Input power (kw) EER Water flow (m 3 /h) Available head pump (kpa) Tank volume (l) Refrigerant type Number of frigorific circuits Number of compressors Expansion tank volume Ø of male water connector Sound power level (dba) LS Sound pressure level* (dba) LS Length (mm) Depth (mm) Height (mm) Weight (kg) CMHG 0 EV x 35 "/ CMHG 4 EV x 35 "/ CMHG 40 EV x 35 "/ 88 () 60 () *Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 0 m. Nominal conditions T outdoor air + 35 C T water inlet + C T water outlet + 7 C OPERATING LIMITS T inlet air to condenser Standard with head pressure control: 0 C / + 45 C Pure water outlet T : + 4 C / + 0 C Consult Technibel for any special climatic conditions which differ significantly from the nominal conditions FACTORYFITTED OPTIONS Type Models Code Safety pump CMHGV 0 to ACCESSORIES Type Models Code Remote «µchiller» control keyboard and display CMHGV 0 to RS 485 communication interface MOBDUS protocol CMHGV 0 to HP and LP gauges CMHGV 0 to Antifreeze hydraulic unit 800 W CMHGV 0 to Set of 6 antivibration pads 5 mm thick CMHGV 0 to WATER CHILLERS AND HEAT PUMPS u n e a v a n c e d a n s l a i r d u t e m p s 33

15 > Heat pumps with hydraulic equipment R 40 A AIR / WATER PHRT FROM 9 TO 8 kw 0 69 PHRT 9/8 PHRT 9 PHRT /6/8 NEW RANGE PHRT : >> Heat pumps conceived for an optimal operation in water rating 40/45 C in Heating mode and 7/ C in Cooling mode Better heating capacities Better EER Better cooling capacities Refrigerant fluid : R 40 A The best COP on the market The lowest noise levels on the market Compact units 90 x 340 x 735 mm 90 x 340 x 35 mm High quality components Scroll compressor with sound insulation high performance heat exchanger with fins for the R 40 A axial fan motor heat exchanger with AISI 36 stainless steel plates and heat insulation, etc. Hydraulic equipment Functions of the control system : Elimination of the buffer receiver vessel Adjustment of the condensation pressure Automatic control of the circulating pump (antifreeze and antiseize function) Defrosting adjusted according to the outdoor temperature Alarm management by means of event logging External communication via a serial interface (Protocol Modbus) Other advantages : Improved access to components Keypad/display fitted to the front panel Dividing bulkhead between the fan and the machinery compartment Option of removing the control panel for a wider opening Stringent manufacturing inspections : Helium waterproof test, dielectrical and electrical test, hydraulic test, Standard equipment water flow switch proportional head pressure control LP switch HP switch Hydraulic filter (connectable) hydraulic equipment (circulating pump 3 speeds, expansion tank, safety valve, water manometer, etc, ) 34

16 > Heat pumps with hydraulic equipment Model Code 30//50 400/3N/50 HEATING Heating capacity (kw) Input power (kw) COP water rating 40 / 45 C COP water rating 30 / 35 C Water flow (m 3 /h) Available head pump (kpa) COOLING Cooling capacity (kw) Input power (kw) EER water rating / 7 C Water flow (m 3 /h) Available head pump (kpa) Refrigerant type Number of refrigeration circuits Number of compressors Expansion tank volume (l) Ø of male water connector Sound power level (dba) Sound pressure level** (dba) Length (mm) Depth (mm) Height (mm) Weight (kg) Nominal conditions HEATING T outdoor air + 7 C (DB)/+ 6 C (WB) T water inlet + 40 C T water outlet + 45 C Temporary information PHRT 9 PHRT PHRT 6 PHRT 8 PHRT 095 F R 40 A 3/ COOLING T outdoor air + 35 C T water inlet + C T water outlet + 7 C PHRT 5 F PHRT 7 F / 3.78* 3.05 / 3.5* 3.67 / 3.80* / 3.75*.4 /.48* R 40 A PHRT 67 F R 40 A PHRT 87 F R 40 A **Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 0 m. * phase/ 3 phase OPERATING LIMITS (pure water) HEATING T outdoor air C (DB) / + 0 C (DB) T water outlet maximum + 53 C T water outlet minimum + 5 C COOLING T outdoor air 0 C (DB) / + 43 C (DB) T water outlet maximum + 0 C T water outlet minimum + 5 C ACCESSORIES Type Models Code Set of flexible length m Ø 3/4 PHRT water pipes length m Ø PHRT / 6 / liters tank insulated PHRT 9 / / 6 / Single startup kit PHRT 9 / (30//50) Remote control keyboard and display PHRT 9 / / 6 / RS 485 communication interface MOBDUS protocol PHRT 9 / / 6 / (please consult us for protocol details) Condensate tank heating cord kit PHRT 9 / / 6 / PRECAUTIONS FOR INSTALLATION 50 X Y Dimensions in mm PHRT 9 PHRT 6 8 X Y WATER CHILLERS AND HEAT PUMPS u n e a v a n c e d a n s l a i r d u t e m p s 35

17 > Heat pumps with hydraulic equipment AIR / WATER PHRV FROM 4 TO 76 kw 0 6 PHRV / PHRV 44/7 > PHRV to 36 PHRV 44 to 7 New range from 49 to 76 kw Improved performance: Increase in the available hydraulic pressure More compact units High quality components Scroll compressor with sound insulation Air heat exchanger: copper tubes with aluminium fins Axial fan motor with variable speed control Heat exchanger with AISI 36L stainless steel plates and heat insulation Hydraulic equipment Functions of the control system : Elimination of the buffer receiver vessel Adjustment of the condensation pressure Automatic control of the circulating pump (antifreeze and antiseize function) Defrosting adjusted according to the outdoor temperature Alarm management by means of event logging External communication via a serial interface (Protocol Modbus) Output for controlling an additional electrical device Simplified operation and maintenance : Keypad/display fitted to the front panel Access panel to the electrical cabinet Access panels at the side and at the front Provision for HP and LP connections Holes to accommodate slings Standard equipment ON/OFF main switch proportional head pressure control HP and LP switches water flow switch phase sequence tester hydraulic equipment (circulating pump with check valve, expansion tank, safety valve, air vent, water manometer, ) hydraulic filter (connectable) condenser coil protection grille 36

18 > Heat pumps with hydraulic equipment Model PHRV PHRV 5 PHRV 3 PHRV 36 Code 400/3N/50 PHR 7 V PHR 57 V PHR 37 V PHR 367 V HEATING Heating capacity (kw) Input power (kw COP Water flow (m 3 /h) Available head pump (kpa) COOLING Heating capacity (kw) Input power (kw) EER Water flow (m 3 /h) Available head pump (kpa) Refrigerant type Number of refrigeration circuits Number of compressors Expansion tank volume (l) Ø of male water connector /4 /4 /4 /4 Sound power level (dba) Sound pressure level* (dba) Length (mm) Depth (mm) Height (mm) Weight (kg) Temporary information Model PHRV 44 PHRV 50 PHRV 64 PHRV 7 Code 400/3N/50 PHR 447 V PHR 507 V PHR 647 V PHR 77 V HEATING Heating capacity (kw) Input power (kw COP Water flow (m 3 /h) Available head pump (kpa) COOLING Heating capacity (kw) Input power (kw) EER Water flow (m 3 /h) Available head pump (kpa) Refrigerant type Tank volume (I) Number of refrigeration circuits Number of compressors Expansion tank volume (l) Ø of male water connector / / / / Sound power level (dba) Sound pressure level* (dba) Length (mm) Depth (mm) Height (mm) Weight (kg) *Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 0 m. Nominal conditions HEATING T outdoor air + 7 C (DB) T outdoor air + 6 C (WB) T water inlet + 40 C T water outlet + 45 C ACCESSORIES COOLING T outdoor air + 35 C T water inlet + C T water outlet + 7 C Operating limits (pure water) HEATING T water outlet maximum + 50 C T water outlet minimum + 30 C Operating limits : please. see technical instructions Type Models Code Remote control keyboard and display PHRV to RS 485 communication interface MOBDUS protocol PHRV to HP and LP gauges PHRV to PHRV PHRV 44 to x PHRV x Set of flexible length m Ø /4 PHRV to water pipes length.5 m Ø / PHRV 44 to Set of 4 antivibration pads 5 mm thick PHRV to liters Tank PHRV to liters Tank PHRV 44 to liters Tank + heating 4 kw PHRV to liters Tank + heating 48 kw PHRV 44 to COOLINGT water outlet maximum + 0 C T water outlet minimum + 4 C u n e a v a n c e d a n s l a i r d u t e m p s 37 WATER CHILLERS AND HEAT PUMPS

19 > Heat pumps with builtin hydraulic module AIR / WATER PMHRV FROM 95 TO 63 kw 0 39 PMHRV 088/44 > The very complete standard equipment enables safe, simple and quick installation. The phase sequence controller ensures the safety of your SCROLL compressor in the event of phase reversal. These compact water chillers can be easily integrated, both on a roof or on the ground ; needed space around the units is reduced Hydraulic equipment : insulated buffer tank water pump with control valves expansion tank safety valve air vent, ) Quality components : Scroll compressor with sound insulation Air heat exchanger : copper tubes with aluminium fins Direct drive axial fans Stainless steel brazed plate heat exchanger protected against freezing and underflows Switchbox Automatic switching of the compressor running order ensures that they age at exactly the same rate Low noise thanks to the use of compressors fitted with soundproofing and antivibration pads and fans with twospeed rotation Maintenance made easy : All access and connections are carried out at the front All panels can be removed Two completely independent refrigerant circuits Electronic controller : easy to see setpoints, adjustments, parameters and alarms three hierarchical access levels (user, installer, maintenance engineer) alarms. Standard equipment ON/OFF main switch proportional head pressure control remote on/off and cooling/heating switch HP and LP switches water flow switch phase sequence tester hydraulic equipment hydraulic filter (connectable) condenser coil protection grille 38

20 > Heat pumps with builtin hydraulic module Model PMHRV 088 PMHRV 00 PMHRV 8 PMHRV 44 Code HEATING 400/3N/50 PMHR 088 EV PMHR 00 EV PMHR 8 EV PMHR 44 EV Heating capacity (kw) Input power (kw) COP Water flow (m 3 /h) Available head pump (kpa) COOLING Cooling capacity (kw) Input power (kw) EER Water flow (m 3 /h) Available head pump (kpa) Refrigerant type Tank volume (l) Number of refrigeration circuits Number of compressors Expansion tank volume (l) Ø of male water connector Sound power level (dba) x 35 / x 35 / x 35 / x 35 / Sound pressure level* (dba) Length (mm) Depth (mm) Height (mm) Weight (kg) *Sound pressure: this level corresponds to that of a unit installed outdoors (free sound field), on a reflective surface, with the measurement being taken at a distance of 0 m. Nominal conditions HEATING T outdoor air + 7 C (DB) T outdoor air + 6 C (WB) T water inlet + 40 C T water outlet + 45 C COOLING T outdoor air + 35 C T water inlet + C T water outlet + 7 C Operating limits (pure water) HEATING T water outlet maximum + 50 C T water outlet minimum + 30 C Operating limits : please, see technical instructions COOLINGT water outlet maximum + 0 C T water outlet minimum + 4 C FACTORYFITTED OPTIONS Type Model Code Safety pump PMHRV 088 to ACCESSORIES Type Models Code Remote «µchiller» control keyboard and display PMHRV 088 to RS 485 communication interface MOBDUS protocol PMHRV 088 to HP and LP gauges PMHRV 088 to Antifreeze hydraulic unit 800 W PMHRV 088 to Set of 6 antivibration pads 5 mm thick PMHRV 088 to WATER CHILLERS AND HEAT PUMPS u n e a v a n c e d a n s l a i r d u t e m p s 39

21 > Terminal Units More choices > 4 terminal units type > 9 sizes > models with infra red remote control in standard Design in accordance with European markets The logical extension to be used with TECHNIBEL water chillers and heat pump APPLICATIONS RESIDENTIAL AND COMMERCIAL 40

22 Water range Terminal Units > Wall type MCW 4 > Floor or ceiling mounted type KPSW 44 > Cassette type CWX 46 > Fan coil units TWX 50 > Remote control for terminal units 56 TERMINAL UNITS u n e a v a n c e d a n s l a i r d u t e m p s 4

23 > Terminal Units Wall type MCW 0 70 MCW >> > > 5 MODELS, 4 SIZES COMPACT UNITS NEW RANGE WITH INFRARED REMOTE CONTROL AS STANDARD > SAME AESTHETIC FOR ALL THE MODELS These models are especially recommended for rooms in which the floor must remain free or for water distribution systems in false ceilings. The active charcoal filter, available as an accessory, deodorises the air. It is used in addition to the standard dust filter. Functions common to all models Heating and cooling by pipe coil Ventilation with filtration. ACCESSORIES Type Models Code High efficiency filter with active charcoal (set of ) MCW / B5B/B5X MCW 3 / 4 B5B/B5X Manual remote control RAB 30 MCW / / 3 / 4 B5B Regulation by valve or ventilation MCW BE5B* Automatic remote control RCC 0 MCW / / 3 / 4 B5B Regulation by valve or ventilation Automatic remote control RCC 0 Regulation by valve or ventilation MCW BE5B (the valve is obligatory when using electric heater) Air ambient temperature sensor, uncased for RCC MCW / / 3 / 4 B5B (change over) MCW BE5B Remote room temperature sensor, MCW / / 3 / 4 B5B cased, for RCC MCW BE5B 3way valve + bypass motorised 30V//50 Hz On/Off function connection / M Kvs.6 All (To be fitted on the exterior of the unit when installing.) * pipe coils with valve + electric heater application 4

24 > Terminal Units Wall type Model MCW MCW BE MCW MCW 3 MCW 4 Type Codes Models with infrared remote control Codes Models without infrared remote control Total cooling capacity (kw)() LS/MS/ Sensible cooling capacity (kw)() LS/MS/ Heating capacity (kw)() LS/MS/ Heating capacity by electric heater (kw) LS Air flow (m 3 /sm 3 /h) MS Water flow in cooling (l/h) () Pressure drop on water in cooling mode (kpa) () Pressure drop on water in heating mode (kpa) () Electrical power supply (V/ph/Hz) Maximum input power (kw) Maximum running current (A) Hydraulic connection Sound power level (dba) LS/MS/ Sound pressure level (dba) to m indoors LS/MS/ Nominal conditions () Air inlet 7 C (DB) / 9 C (WB) Water inlet 7 C Water outlet C pipe coils MCW B5X MCW B5B 0.80 / / / / / / // / G female 37 / / 44 8 / / 35 pipe coils + E MCW BE5B 0.80 / / / / / / // / G female 37 / / 44 8 / / 35 () Air inlet 0 C Water inlet 50 C (same water flow as in condition ()) T maxi at water inlet 60 C pipe coils MCW B5X MCW B5B 0.96 / / / /.3.49 / / // / G female 35 / / 45 6 / / 36 pipe coils MCW 3B5X MCW 3B5B.9 /.53 / /.89 / / 3.50 / // / G female 33 / 45 / 54 4 / 36 / 45 pipe coils MCW 4B5X MCW 4B5B.6 / 3.4 / /.50 / / 4.50 / // / G female 48 / 53 / / 44 / 50 0 kpa = mce PRECAUTIONS FOR INSTALLATION AND PHYSICAL CHARACTERISTICS 000 A B C Dimensions in mm MCW MCW MCW 3 MCW 4 A (mm) B (mm) C (mm) Weight (kg) TERMINAL UNITS u n e a v a n c e d a n s l a i r d u t e m p s 43

25 > Terminal Units Floor or ceiling mounted type KPSW 0 7 KPSW NEW SIZES > AESTHETIC AND SILENCE > NEW RANGE WITH INFRARED REMOTE CONTROL AS STANDARD >> The attractive slimline KPSW units can be installed as console or ceiling mounted units (to leave floor and wall space free): this permits uniform installation throughout the building. The active charcoal filter, available as an accessory, deodorises the air. It is used in addition to the standard dust filter. Functions Heating and cooling by pipe coil Ventilation with integral filtration. ACCESSORIES Type Models Code High efficiency filter with active charcoal KPSW /3/4 B5B/B5X Set of insulated hoses for length 50 mm KPSW /3/4 B5B/B5X hydraulic connection length 550 mm KPSW /3/4 B5B/B5X Manual remote control RAB 30 KPSW /3/4 B5B Regulation by valve or ventilation Automatic remote control RCC 0 KPSW /3/4 B5B Regulation by valve or ventilation Air ambient temperature sensor, uncased for RCC KPSW /3/4 B5B (change over or air intake) Remote room temperature sensor, KPSW /3/4 B5B cased, for RCC 3way valve + bypass motorised 30V//50 Hz On/Off function connection / M Kvs.6 All (To be fitted on the exterior of the unit when installing.) 44

26 > Terminal Units Floor or ceiling mounted type Model KPSW KPSW 3 KPSW 4 Type Codes Models with infrared remote control Codes Models without infrared remote control Total cooling capacity (kw)() LS/MS/ Sensible cooling capacity (kw)() LS/MS/ Heating capacity (kw)() LS/MS/ LS Air flow (m 3 /sm 3 /h) MS Water flow in cooling (l/h) () Pressure drop on water in cooling mode (kpa) () Pressure drop on water in heating mode (kpa) () Electrical power supply (V/ph/Hz) Maximum input power (kw) Maximum running current (A) Hydraulic connection Sound power level (dba) LS/MS/ Sound pressure level (dba) to m indoors LS/MS/ Nominal conditions () Air inlet 7 C (DB) / 9 C (WB) Water inlet 7 C Water outlet C pipe coils KPSW B5X KPSW B5B.07 /.80/ /.50 / /.9 / / / / // / G male 35 / 43 / 48 7 / 35 /40 () Air inlet 0 C Water inlet 50 C (same water flow as in condition ()) T maxi at water inlet 60 C pipe coils KPSW 3 B5X KPSW 3 B5B.3 /.40 / /.80 / / 3.40 / /0 0.9/ / // / G male 35 / 45 / 50 7 / 37 /4 pipe coils KPSW 4 B5X KPSW 4 B5B.77 / 3.00 / /.50 / / 4.30 / / / / // / G male 40 / 5 / 54 3 / 43 /46 0 kpa = mce PRECAUTIONS FOR INSTALLATION AND PHYSICAL CHARACTERISTICS Dimensions in mm Total weight : 3.5 kg TERMINAL UNITS u n e a v a n c e d a n s l a i r d u t e m p s 45

27 > Terminal Units Cassette type CWX 3, CWX 5 (600 x 600) 0 56 CWX 3/5 > The CWX 3 and CWX 5 cassettes are a chilled water terminal unit designed for service sector premises such as shops, offices and hotels. This appliance can be used for either heating or cooling, when using hot or cold water circulation. The CWX 3 BE and CWX 5 BE uses cold water for cooling and are equipped with an electric heater for heating. These cassettes units can be installed extremely discreetly, their dimensions (600 x 600) being the same as those of a false ceiling panel. These cassettes are fitted with a manual air vent and a condensate drain pump. They are prepunched (Ø 70 mm) to enable connection with fresh air intake. Functions Heating and cooling by pipe coil Ventilation with filtration (regenerable filter) 46 Models CWX 3 B CWX 3 BE CWX 3 BW CWX 5 B CWX 5 BE CWX 5 BW Type Codes Models with infraredremote control Codes grille Models with infrared remote control Codes Models without infrared remote control Codes grille Models without infrared remote control Total cooling capacity (kw) () LS/MS/ Sensible cooling capacity (kw) () LS/MS/ Heating capacity (kw) () LS/MS/ Heating capacity by electric heater (kw) Heating capacity LS/MS/ additional coil (kw) (3) (m Air flow 3 /s) (m 3 /h) Water flow in cooling (l/h) () Water flow additional coil (l/h) (3) Pressure drop on water in cooling mode (kpa)() Pressure drop on water in heating mode (kpa)() Pressure drop on water additional coil (kpa) (3) Electrical power supply (V/ph/Hz) Maximum power input (kw) Maximum current input (A) Hydraulic connection Sound power level (dba) LS/MS/ Sound pressure level (dba) (4) Nominal conditions () Air inlet 7 C (DB) / 9 C (WB) Water inlet 7 C Water outlet C pipe coils CWX 3 B5X K70N097T CWX 3 B5B K 70 N 090 T.5/.35/.60.9/.09/.3.83/3./ /0.8/0.44 LS/MS/ 400/460/ // / G fem. 4/44/46 LS/MS/ 3/35/37 pipe coils + E CWX 3 BE5B K 70 N 090 T.7/.88/.08.53/.67/.85.4/.64/ /0.8/ /460/ // / G fem. 4/44/46 3/35/37 4 pipe coils CWX 3 BW5B K 70 N 090 T.7/.88/.08.53/.67/.85./.34/.5 0./0.8/ /460/ // / G fem. 4/45/46 33/36/37 () Air inlet 0 C Water inlet 50 C / same water flow as condition () ( pipe coils) (3) Air inlet 0 C Water inlet 70 C (4 pipe coils) Water outlet 60 C (4 pipe coils) pipe coils CWX 5 B5X K70N097T CWX 5 B5B K 70 N 090 T 3.60/4.0/ /3./ /4.85/ /0.75/ /630/ // / G fem. 48/5/56 39/4/47 pipe coils + E CWX 5 BE5B K 70 N 090 T 3.4/3.69/4.3.5/.89/ /4.37/ tubes CWX 5 BW5B K 70 N090 T.88/3.8/3.76.4/.56/.98.78/.98/ /0.75/ /0.75/ /630/ /630/ //50 30// / G fem. / G fem. 48/5/56 48/5/56 39/4/47 39/4/47 (4) to m indoors

28 > Terminal Units Cassette type CWX 6, CWX 8, CWX CWX 6/8/0 > The CWX 6,8 and 0 cassettes are chilled water terminal units designed for service sector premises such as shops, offices and hotels. They can be installed in a false ceiling in order to hide the supply pipes and leave wall space completely clear. These cassettes are fitted with a manual air vent and a condensate drain pump. Functions Heating and cooling by pipe coil Ventilation with filtration (regenerable filter) Models CWX 6 CWX 8 CWX 0 Type Codes Models with infrared remote control Codes grille Models with infrared remote control Codes Models without infrared remote control Codes grille Models without infrared remote control Total cooling capacity (kw) () LS/MS/ Sensible cooling capacity (kw) () LS/MS/ Heating capacity (kw) () LS/MS/ Air flow (m 3 /s) LS/MS/ (m 3 /h) Water flow in cooling (l/h) () Pressure drop on water in cooling mode (kpa) () Pressure drop on water in heater mode (kpa) () Electrical power supply (V/ph/Hz) Maximum input power (kw) Maximum running current (A) Hydraulic connection Sound power level (dba) LS/MS/ Sound pressure level (dba) (3) LS/MS/ pipe coils CWX 6 B5X K 70 N 09 T CWX 6 B5B K 70 N 094 T 4.0 / 5.00 / / 3.80 / / 6.40 / / 0.94 / / 060 / // /4 G fem. 5 / 48 / 55 4 / 39 / 46 pipe coils CWX 8 B5X K 70 N 0 T CWX 8 B5B K 70 N 095 T 5.50 / 6.50 / / 5.40 / / 9.50 / / / / 090 / // ,5 3/4 G fem. 35 / 46 / 50 6 / 37 / 4 pipe coils CWX 0 B5X K 70 N 0 T CWX 0 B5B K 70 N 095 T 6.3 / 8.09 / / 6. / / 0.60 / / 0.47 / / 700 / // /4 G fem. 43 / 49 / / 40 / 48 TERMINAL UNITS Nominal conditions () Air inlet 7 C (DB) / 9 C (WB) Water inlet 7 C Water outlet C () Air inlet 0 C Water inlet 50 C / same water flow as conditions () (3) to m indoors u n e a v a n c e d a n s l a i r d u t e m p s 47

29 > Terminal Units Cassette type ACCESSORIES Type Models Code Manual remote control RAB 30 Regulation by On/Off valve control CWX 3/5/6/8/0 B5B CWX 3/5 BW5B Regulation by On/Off valve control Cool + electric heater CWX 3/5 BE5B Automatic remote control RCC 0 CWX 3/5/6/8/0 B5B Regulation by On/Off valve control Automatic remote control RCC 0 CWX 3/5 BE5B/BW5B Regulation by On/Off valve control Remote room temperature sensor uncased for RCC for change over CWX 3/5/6/8/0 B5B CWX 3/5 BE5B for air intake All Remote room temperature sensor, cased, All for RCC 3way valve + bypass Cassette pipes / CWX 3/5 B5B/BE5B/B5X motorised 30V//50Hz 3/4 CWX 6/8/0 B5B/B5X On/Off function Cassette 4 pipes / CWX 3/5 BW5B x (To be fitted on the exterior of the unit when installing.) CWX 3/5 Dimensions in mm 300 A Condensate drain : Ø 0 mm B Main Coil water inlet : /" (female) C Main Coil water outlet : /" (female) D Additional coil water inlet : /" (female) E Additional coil water outlet : /" (female) Empty weight : 8 kg CWX 3 0 kg CWX 5 Grille : 3 kg Pump lift alove unit : 00 mm 500 CWX 6/8/0 CWX 6 CWX 8/0 Unit Facade/assembly L H X Y Z CWX 6 CWX 8/0 3 kg 9 kg 5 kg 7 kg CWX 6 CWX 8/0 A 80 0 B (ceiling hole dimension) 757 (anchor hook centerline) X A (ceiling hole dimension) B (anchor hook centerline) Centre of the grille Condensate drain pipe Hydraulic connections A B C D E F Condensate drain: Ø3 mm outdoor Water inlet: 3/4 gaz female Water outlet: 3/4 gaz female Air vent valve Electrical cable passage Fresh air intake: 60 mm x 55 mm Pump lift alove unit : 50 mm 48

30 > Terminal Units Fan coil units TWX 0 45 TWX TWX / NC TWX / CV TWX / CH TWX fan coil units include 7 sizes in pipe version, each size being designed to match 5 types of installation: TWX CV : vertical installation with casing TWX CH : horizontal installation or floor model with casing TWX NC : horizontal or vertical installation without casing The factoryfitted options and the accessories extend the range to include a pipe + electric heater version and a 4 pipe version. painted metal sheet casing synthetic air filter copper / aluminium coil with left hand side connection (can be changed on site). Functions common to all models Heating and cooling by pipe coil Ventilation with filtration MODELS Size Code Models without casing TWX / NC TWX / NC TWX 0 NC 00T TWX 03 NC 00T TWX 04 NC 00T TWX 05 NC 00T TWX 06 NC 00T TWX 08 NC 00T TWX NC 00T TWX / CV 0 03 TWX 0 CV 00T TWX 03 CV 00T 04 TWX 04 CV 00T 05 TWX 05 CV 00T Models with casing TWX / CH TWX / CH TWX 06 CV 00T TWX 08 CV 00T TWX CV 00T TWX 0 CH 00T TWX 03 CH 00T TWX 04 CH 00T TWX 05 CH 00T TERMINAL UNITS 06 TWX 06 CH 00T 08 TWX 08 CH 00T TWX CH 00T u n e a v a n c e d a n s l a i r d u t e m p s 49

31 > Terminal Units Fan coil units Size Total cooling capacity (kw) Sensible cooling capacity (kw) Heating capacity (kw) LS () MS LS () MS LS pipe coil () MS Electric Heater power (kw) (3) Heating capacity (kw) LS 4 pipe coil (4) MS Air flow (m 3 /sm 3 /h) LS (5) MS Water flow in cooling (l/h) LS () MS Water flow aditional coil (l/h) LS (4) MS Maximum static pressure (Pa) (0) MS/ Pressure drop on water cooling mode (kpa) LS () MS Pressure drop on water heating mode (kpa) LS pipe coil () MS Pressure drop on water heating mode (kpa) LS 4 pipe coil (4) MS Fan motor characteristics (6) (W) 30 V//50 Hz (7) (A) Hydraulic pipes connection 4 pipes Cooling Heating Sound power level (dba) (8) LS/MS/ Sound pressure level (dba) (9) LS/MS/ Nominal conditions () Air inlet 7 C (DB)/9 C (WB) Water 7 C / C () Air inlet 0 C Water inlet 50 C, same water flow () (3) As accessory, limited static pressure (see specifications sheet) Operation is forbidden with a pipe system (cooling and heating) / / G Fem. / G Fem. / G Fem. 36/44/5 7/35/ / / G Fem. / G Fem. / G Fem. 38/44/50 9/35/ / / G Fem. / G Fem. / G Fem. 40/48/55 3/39/46 (4) Air inlet 0 C Water 70 C / 60 C (5) Measurement with direct air outlet (available pressure = 0 Pa) T Air inlet 0 C (6) Total input power (at high speed) (7) Total running current (at high speed) (8) Tests performed in compliance with standard ISO 3743 (9) at m indoors / / G Fem. / G Fem. / G Fem. 44/5/59 35/43/ / /4 G Fem. 3/4 G Fem. / G Fem. 44/5/59 35/43/ / /4 G Fem. 3/4 G Fem. / G Fem. 48/58/66 39/49/ / /4 G Fem. 3/4 G Fem. / G Fem. 57/63/7 48/54/6 Fem. = female (0) Applications requiring static pressure should not use the LS function. PHYSICAL CHARACTERISTICS CASED UNITS A A A C C B C B B TWX CV Vertical model with casing TWX CH Floor model with casing TWX CH Horizontal model with casing NONCASED UNITS F G TWX NC For horizontal or vertical installation D E Size 0 Size 03 Size 0405 Size 0608 Size A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm)

32 > Terminal Units Fan coil units ACCESSORIES OR FACTORYFITTED OPTIONS Type Model Accessories code Factoryfitted options code Controls to be build in 3 speeds select switch On/Off (*) Regulation by ventilation control (3 speeds On/Off electromechanical thermostat) Cooling only or heating only Regulation by ventilation control (3 speeds On/Off electromechanical thermostat manual changeover) Electronic regulation by On/Off valve control Electronic regulation by On/Off valve control Electronic regulation by On/Off valve control + electric heater Control panel for motorised damper Kit 3way valves + bypass, motorised 30V//50 Hz / G M Kvs.6 On/Off function for main heating coil 3/4 G M Kvs.5 (recommended accessory: auxiliary drain pan) Kit 3way valves + bypass, motorised 30V//50 Hz Cool/Heat / G M Kvs.6 On/Off function Cool 3/4 G M Kvs.5 for additional heating coil Heat / G M Kvs.6 (recommended accessory: auxiliary drain pan) Additional heating coil for 4 pipe system Electric heater kit.5 kw.5 kw.6 kw.0 kw 3.0 kw CV CH (vertical) CV pipe coils CH (vertical) pipe coils CV pipe coils CH (vertical) pipe coils CV pipe coils CH (vertical) pipe coils CV 4 pipe coils CH (vertical) 4 pipe coils CV pipe coils+e CH (vertical) pipe coils+e CV Sizes 0 to 05 Sizes 06 to Sizes 0 to 05 Sizes 06 to Size 0 Size 03 Sizes Sizes Size Size 0 vertical Size 0 horizontal Size 03 Sizes Sizes K 70 P 034 Z K 70 P 035 Z K 70 P 036 Z K 70 P 039 Z K 70 P 039 Z K 70 P 039 Z TERMINAL UNITS K 70 P 040 Z K 60 L 080 Z K 60 L 08 Z K 60 L 08 Z K 60 L 083 Z K 70 B 009 Z K 70 B 00 Z K 70 B 0 Z K 70 B 0 Z K 70 B 03 Z K 70 C 035 Z K 70 C 036 Z K 70 C 037 Z K 70 C 038 Z K 70 C 039 Z K 70 P 034 M K 70 P 035 M K 70 P 036 M K 70 P 039 M K 70 P 039 M K 70 P 039 M K 70 P 040 M K 60 L 080 M K 60 L 08 M K 60 L 08 M K 60 L 083 M K 70 B 009 M K 70 B 00 M K 70 B 0 M K 70 B 0 M K 70 B 03 M K 70 C 035 M K 70 C 036 M K 70 C 037 M K 70 C 038 M K 70 C 039 M * The select switch does not provide temperature control. u n e a v a n c e d a n s l a i r d u t e m p s 5

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

FAN COIL. Technibel is a trademark of Nibe Energy System France used under license

FAN COIL. Technibel is a trademark of Nibe Energy System France used under license FAN COIL Technibel is a trademark of Nibe Energy System France used under license 1 FAN COIL Consisting of a fan unit, a heat exchange element and a filter, fan coils are ideal machines for summer air

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

Condensing unit type EPSILON-ECHOS LE Technical information manual

Condensing unit type EPSILON-ECHOS LE Technical information manual Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4. AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave

More information

Inverter Air Conditioning for Light Commercial Use

Inverter Air Conditioning for Light Commercial Use Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

We have been working in an ideal climate for thirty years.

We have been working in an ideal climate for thirty years. Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the

More information

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE AquaFREE system Technical Catalogue Outdoor units: RAS(3~5)HVRNE RAS(4/5)HRNE Indoor units: RWM(3~5)FSN1E RWM(3~5)FSN1E(4.5/6)H(1/3) RWM(3~5)FSN1ES1 RWM(3~5)FSN1E(4.5/6)SH(1/3) Specifications in this

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Versati Air to Water Heat Pump

Versati Air to Water Heat Pump Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Product catalog UNT-PRC011-E4

Product catalog UNT-PRC011-E4 Product catalog 4-way fan coil cassettes with AC fan motor technology - model CWS sizes 00-06 4-way fan coil cassettes with EC fan motor technology - model CWE sizes 01-05 Contents Introduction 4 Main

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Split System Cooling Product Data

Split System Cooling Product Data Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess

More information

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Air Conditioning. Light Commercial, Commercial and Industrial

Air Conditioning. Light Commercial, Commercial and Industrial Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air Conditioning Light Commercial, Commercial and Industrial Systemair Trust

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

HDA -----------------------------------------------------------

HDA ----------------------------------------------------------- ----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS

More information

YUTAKI S. Domestic Heating

YUTAKI S. Domestic Heating YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance

More information

Industrial infrared heater IR For premises with large volumes and high ceilings

Industrial infrared heater IR For premises with large volumes and high ceilings 3 3000 6000 W Electrical heat 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume

More information

Controls for fan coil units and cassettes

Controls for fan coil units and cassettes Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

Product catalog UNT-PRC017-E4

Product catalog UNT-PRC017-E4 Product catalog One-way fan coil cassettes with AC fan motor technology - model CFAS One-way fan coil cassettes with EC fan motor technology - model CFAE Sizes 16-26-36 UNT-PRC017-E4 Contents Introduction

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. www.airedale.com. Typical Applications

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. www.airedale.com. Typical Applications 5-21kW - 21kW > Ecotel Indoor Range Typical Applications > Telecommunications > Internet service providers > Computer rooms > Switching / Relay stations www.airedale.com Specifications Ecotel Indoor The

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW

More information

GREE, MAKING BETTER AIR CONDITIONERS

GREE, MAKING BETTER AIR CONDITIONERS GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Add:Jinji RD.Qianshan Zhuhai 519070,Guangdong,China Tel: (+86-756)8614883 Fax: (+86-756)8627140 Email: gree@gree.com.cn http://www.gree.com.cn Heat Pump Water Heater

More information

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Split System Heat Pump Product Data

Split System Heat Pump Product Data Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections High efficiency HYRID heat pumps with E.V.I compressor in two sections infolinia: +48 691 262 691-20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency hybrid heat pumps has been specifically designed

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Manual Code VR-197-0-0002

Manual Code VR-197-0-0002 USE, MAINTENANCE AND INSTALLATION MANUAL AIR CONDITIONERS FOR ELECTRICAL ENCLOSURES Manual Code VR-197-0-0002 VZ1550 VZ1850 VZ1400 VZ2000 ABB SACE S.p.A. An ABB Group Company Automation and Distribution

More information

Brochure 2012-2013.EX

Brochure 2012-2013.EX CLIMA CANAL Brochure 2012-2013.EX CLIMA CANAL Complete climate control and high power Heating, cooling, ventilation. Despite it s modest size, clima canal is a powerful heating, cooling and ventilation

More information

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

AIR-CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information