Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Size: px
Start display at page:

Download "Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems"

Transcription

1 WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic cables LL : flexible solutions with fibre-optic cable systems FFibre-optic sensors without baggage. Safe and simple switching: The combination of photoelectric switches WLL 0(T) and fibreoptic cables LL offers extremely simple handling and intelligent system options for a wide range of applications. For standard applications, but also for demanding applications such as detection of very small objects, recognition of colour marks or transparent materials. You choose: Suitable WLL 0(T) versions, optimised for various typical uses, are available WLL 0T with teach-in: This teach-in version simplifies handling: the switching threshold and switching hysteresis are automatically set, via a push button (Teach-in). Sender LED red or green light: Selects the most suitable emitted light for optimum detection of colour contrasts. WLL 0- with manual switching threshold adjustment: The cost-effective solution for all standard applications. WLL 0 High Speed: 0,000 switching operations per second - the optimum for high speed applications. WLL 0A with analogue output: For easy measurement and control. Large selection of suitable fibreoptic cables: Fibre-optic cable range LL. For WLL 0, there are around 0 LL versions, offering maximum flexibility and choice for your requirements. Typical uses for these WLL 0 / LL fibre-optic cable combinations: semiconductor industry, electronics assembly, packaging technology, handling and assembly systems, special-purpose machinery, construction and precision engineering. SENSICK CATALOGUE

2 WLL 0(T) n In pick-and-place systems, WLL 0(T) photoelectric switches with LL plastic fibre-optic cables are used in a wide variety of configurations to monitor the presence or position of minute objects. b Fibre-optic cables are widely used in the electronics industry. For example, fibre-optic cables with integrated 0 angle used for detecting contact pins in locations where space is restricted. v WLL 0(T) units with red or green transmission light and LL plastic fibreoptic cables for detecting print marks used to control labelling machines. m LL fibre-optic cables for special applications: here LL cables with Teflon jacket are the right choice for harsh environments (i.e. contact with acids, alkaline solutions, detergents or oils) SENSICK CATALOGUE

3 WLL 0-, red light, manual sensitivity adjustment - DC Scanning range mm Through-beam mode Proximity mode Scanning distance mm Dimensional drawing. ø.. Sender LED red for standard applications anual sensitivity adjustment Simple installation and alignment.. ~ ø Adjustments possible in ax SENS. 0 DLY L. D. Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends ounting bracket, included with delivery (see Accessories) Connector Indication of correct fibre-optic cable mounting Indicator LED orange: lights up when switching output is active LED signal strength indicator green, lights up when light received < 0. or >. (switching threshold = ) Sensitivity scale 0 0 Sensitivity control (0 revolutions) Selector switch for delay: DLY (=) /, 0 ms fixed Selector switch: L. (light switching) / D. (dark switching) Connection type WLL0-N WLL0-P WLL0-N0 WLL0-P0 WLL0-N0 WLL0-P0 See chapter Accessories Connector,, -pin Connector,, -pin Fibre-optic cable Tip adapters ounting systems x 0. mm² brn blu blk L+, -pin, -pin NC 0 SENSICK CATALOGUE

4 WLL 0- Technical data WLL0- N N0 N0 P P0 P0 Operating distance mm ) Fibre-optic cable (proximity system): LL-DK0 Adjustment of operating distance Poti, 0 revolutions ) Scanning range max. typ. Fibre-optic cable (through-beam system) Operating range, recommended Fibre-optic cable (through-beam system) 0...,000 mm LL-TB0 and tip adapter LL-TA mm LL-TB0 Sensitivity adjustment Poti, 0 revolutions ) Light source, light type LED, red light, 0 nm ) Light spot diameter Angle of dispersion Depends on scanning range Supply voltage V s V DC ) Residual ripple 0 % ) Power consumption 0 ma ) Switching outputs Switching mode Output current I a max Approx. see LL fibre-optic data NPN: open collector: PNP: open collector: Light/dark switching, switchable 00 ma Response time 0. ms ) Switching frequency,000 Hz ) Time delay 0 ms fix, selectable by sliding switch Time type Off delay t Connection type Cable, Ø. mm, PVC, m ) VDE protection class Connector,, -pin Connector,, -pin Circuit protection V s connections reverse-polarity protected / In-/outputs short-circuit protected / Interference pulse suppression / Outputs overcurrent and short-circuit protected Enclosure rating IP 0) Ambient temperature operation - C... + C Ambient temperature storage -0 C C Weight Approx. 0 g Housing material ABS/PC ) Object with 0 % remission (based on standard white to DIN 0) ) Sensitivity scale 0 ) Average service life 00,000 h at T a = + C ) Limit values ) may not exceed or fall short of V s tolerances ) without load ) Signal transit time with resistive load ) with light/dark ratio : ) do not bend below 0 C 0) with correctly attached fibre-optic cable LL and closed protection hood Function diagram for WLL 0- WLL 0- Orange LED display: lights up when switching output is active. Dependent on setting of light/ dark selector switch Light received >. Switching threshold () Light received < 0. Green LED display: lights up when light received is < 0. or >. (based on the switching threshold, switching threshold = ). Switching output (light-switching) t 0 ms Switching output (dark-switching) Indicator LED, green Ordering information Type Order no. WLL0-N 0 WLL0-N0 0 WLL0-N0 0 WLL0-P 0 WLL0-P0 0 WLL0-P SENSICK CATALOGUE

5 WLL 0-, green light, manual sensitivity adjustment - DC Scanning range mm Through-beam mode Proximity mode Scanning distance 0... mm Dimensional drawing. ø.. Sender LED green for standard applications and print mark recognition anual sensitivity adjustment Simple installation and alignment.. ~ ø Adjustments possible in ax SENS. 0 DLY L. D. Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends ounting bracket, included with delivery (see Accessories) Connector Indication of correct fibre-optic cable mounting Indicator LED orange: lights up when switching output is active LED signal strength indicator green, lights up when light received < 0. or >. (switching threshold = ) Sensitivity scale 0 0 Sensitivity control (0 revolutions) Selector switch for delay: DLY (=) /, 0 ms fixed Selector switch: L. (light switching) / D. (dark switching) Connection type WLL0-N WLL0-P WLL0-N0 WLL0-P0 WLL0-N0 WLL0-P0 See chapter Accessories Connector,, -pin Connector,, -pin Fibre-optic cable Tip adapters ounting systems x 0. mm² brn blu blk L+, -pin, -pin NC SENSICK CATALOGUE

6 WLL 0- Technical data WLL0- N N0 N0 P P0 P0 Operating distance 0... mm ) Fibre-optic cable (proximity system): LL-DK0 Adjustment of operating distance Poti, 0 revolutions ) Scanning range max. typ. Fibre-optic cable (through-beam system) Operating range, recommended Fibre-optic cable (through-beam system) 0...,00 mm LL-TB0 and tip adapter LL-TA mm LL-TB0 Sensitivity adjustment Poti, 0 revolutions ) Light source, light type LED, green light, 0 nm ) Light spot diameter Angle of dispersion Depends on scanning range Supply voltage V s V DC ) Residual ripple 0 % ) Power consumption 0 ma ) Switching outputs Switching mode Output current I a max Approx. see LL fibre-optic data NPN: open collector: PNP: open collector: Light/dark switching, switchable 00 ma Response time 0. ms ) Switching frequency,000 Hz ) Time delay 0 ms fix, selectable by sliding switch Time type Off delay t Connection type Cable, Ø. mm, PVC, m ) VDE protection class Connector,, -pin Connector,, -pin Circuit protection V s connections reverse-polarity protected / In-/outputs short-circuit protected / Interference pulse suppression / Outputs overcurrent and short-circuit protected Enclosure rating IP 0) Ambient temperature operation - C... + C Ambient temperature storage -0 C C Weight Approx. 0 g Housing material ABS/PC ) Object with 0 % remission (based on standard white to DIN 0) ) Sensitivity scale 0 ) Average service life 00,000 h at T a = + C ) Limit values ) may not exceed or fall short of V s tolerances ) without load ) Signal transit time with resistive load ) with light/dark ratio : ) do not bend below 0 C 0) with correctly attached fibre-optic cable LL and closed protection hood Function diagram for WLL 0- WLL 0- Orange LED display: lights up when switching output is active. Dependent on setting of light/ dark selector switch Light received >. Switching threshold () Light received < 0. Green LED display: lights up when light received is < 0. or >. (based on the switching threshold, switching threshold = ). Switching output (light-switching) t 0 ms Switching output (dark-switching) Indicator LED, green Ordering information Type Order no. WLL0-N 0 WLL0-N0 0 WLL0-N0 0 WLL0-P 0 WLL0-P0 0 WLL0-P SENSICK CATALOGUE

7 WLL 0-, High Speed - DC Scanning range mm Through-beam mode Proximity mode Scanning distance 0... mm Dimensional drawing. ø.. High speed 0,000/sec., for extremely fast processes Sender LED red anual sensitivity adjustment Time delay 0 ms for signal extension... ~0 ø Adjustments possible in ax SENS. 0 DLY L. D. Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends ounting bracket, included with delivery (see Accessories) Connector Indication of correct fibre-optic cable mounting Indicator LED orange: lights up when switching output is active LED signal strength indicator green, lights up when light received < 0. or >. (switching threshold = ) Sensitivity scale 0 0 Sensitivity control (0 revolutions) Selector switch for delay: DLY (=) /, 0 ms fixed Selector switch: L. (light switching) / D. (dark switching) Connection type WLL0-N WLL0-P WLL0-N0 WLL0-P0 WLL0-N0 WLL0-P0 See chapter Accessories Connector,, -pin Connector,, -pin Fibre-optic cable Tip adapters ounting systems x 0. mm² brn blu blk L+, -pin, -pin NC SENSICK CATALOGUE

8 WLL 0- Technical data WLL0- N N0 N0 P P0 P0 Operating distance 0... mm ) Fibre-optic cable (proximity system): LL-DB0 Adjustment of operating distance Poti, 0 revolutions ) Scanning range max. typ. Fibre-optic cable (through-beam system) Operating range, recommended Fibre-optic cable (through-beam system) 0...,00 mm LL-TB0 and tip adapter LL-TA mm LL-TB0 Sensitivity adjustment Poti, 0 revolutions ) Light source, light type LED, Red light, 0 nm ) Light spot diameter Angle of dispersion Depends on scanning range Supply voltage V s V DC ) Residual ripple 0 % ) Power consumption 0 ma ) Switching outputs Switching mode Output current I a max Approx. see LL fibre-optic data NPN: open collector: PNP: open collector: Light/dark switching, switchable 00 ma Response time 0 µs ) Switching frequency 0,000 Hz ) Time delay 0 ms fix, selectable by sliding switch Time type Off delay t Connection type Cable, Ø. mm, PVC, m ) VDE protection class Connector,, -pin Connector,, -pin Circuit protection V s connections reverse-polarity protected / In-/outputs short-circuit protected / Interference pulse suppression / Outputs overcurrent and short-circuit protected Enclosure rating IP 0) Ambient temperature operation - C... + C Ambient temperature storage -0 C C Weight Approx. 0 g Housing material ABS/PC ) Object with 0 % remission (based on standard white to DIN 0) ) Sensitivity scale 0 ) Average service life 00,000 h at T a = + C ) Limit values ) may not exceed or fall short of V s tolerances ) without load ) Signal transit time with resistive load ) with light/dark ratio : ) do not bend below 0 C 0) with correctly attached fibre-optic cable LL and closed protection hood Function diagram for WLL 0- WLL 0- Orange LED display: lights up when switching output is active. Dependent on setting of light/ dark selector switch Light received >. Switching threshold () Light received < 0. Green LED display: lights up when light received is < 0. or >. (based on the switching threshold, switching threshold = ). Switching output (light-switching) t 0 ms Switching output (dark-switching) Indicator LED, green Ordering information Type Order no. WLL0-N 0 WLL0-N0 0 WLL0-N0 0 WLL0-P 0 WLL0-P0 0 WLL0-P SENSICK CATALOGUE

9 WLL 0A, red light, analogue DC Scanning range mm Through-beam systems Dimensional drawing R. -R. Scanning distance mm. Proximity systems Analogue output voltage... V Large range of suitable LL fibre-optic cables Ideal for more complex requirements, e.g. positioning tasks, turbidity/transmission measurement, contrast resolution. ø. approx R approx Adjustments possible WLL 0A-V WLL 0A-V0 WLL 0A-V0 in ax SENS ms 0 ms Sender LED, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood: can be raised at both ends, removable ounting bracket, included (see Accessories) : analogue output with saturation ( V) LED signal strength indicator, green: lights up when light received Sensitivity scale, min./max. = 0 Sensitivity control (min./max. = revolutions) Selector switch for analogue output response time Connection types WLL 0A-V0 WLL 0A-V0 WLL 0A-V See chapter Accessories Cables and connectors ounting systems Fibre-optic cables -pin, brn blu blk... V -pin, brn blu blk wht... V NC l mm brn blu blk L+... V SENSICK CATALOGUE

10 WLL 0A Technical data WLL 0T- V V 0 V0 Suitable fibre-optic cable LL plastic fibre-optic cables Scanning range ) Depends on fibre-optic cable used Recommended operating ranges ) max mm (through-beam syst.) (with tip adapters mm) Recommended operating distance ) max mm ) (proximity system) Light source ), light type LED, visible red light Light spot diameter of LL Depends on scanning range Disp. angle of LL fibre-optic cable Approx. ) Supply voltage V ) S V DC Ripple ) 0% Current consumption ) 0 ma Analogue output Voltage output... V V = no light received V = saturation Load current (max.) 0 ma Output resistance (Ri) Ω Load resistance kω (recommended) Response time, selectable ) ms/0 ms Sensitivity, adjustable Potentiometer, turns ) Connection types cable 0) PVC, m; x 0. mm, l.0 mm plug, -pin plug, -pin Cable extension max. 00 m; signal loss to be expected Circuit protection ) A, C, D VDE protection class Enclosure rating IP 0 Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable Approx. 0 g with plug Approx. 0 g Housing material ABS ) See Accessories; selection table for LL fibre-optic cables ) Object with 0 % remission (based on standard white to DIN 0) ) Average service life 00,000 h at T A = + C ) Deviations, see data for LL ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) Delay time: change in received light/ change in analogue output, (0 % of upper range value) ) Scale 0 0) Do not bend below 0 C ) A = V S connections reverse-polarity protected C = Interference pulse suppression D = Outputs overcurrent and shortcircuit protected Analogue output (V) WLL 0A, analogue, typical curves V SENS. max. WLL 0A LL-TB0 Analogue output (V) V SENS. max. WLL 0A LL-DB0 Order information Type WLL 0A-V WLL 0A-V0 WLL 0A-V0 Order no SENS. / SENS. / 0 (mm) Scanning range (mm) 0 (mm) Scanning distance (mm) SENSICK CATALOGUE

11 WLL 0T, red light, teach-in DC Scanning range mm Through-beam systems Dimensional drawing R. -R. Scanning distance mm. Proximity systems Red sender LED For standard applications and mark recognition Easy alignment and commissioning by teach-in. ø. approx R approx Adjustments possible WLL 0T-P WLL 0T-P0 WLL 0T-N WLL 0T-P 0 WLL 0T-N 0 DLY L. D. SET RUN 0 WLL 0T-N0 0 LED sender, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends, removable ounting bracket, included (see Accessories) Orange LED indicator, lights up when switching output is active Green LED reception indicator, lights up when light received is < 0. or >. (switching threshold = ) delay selector switch: DLY (on)/, 0 ms fixed Selector switch: L. (light-switching)/ D. (dark-switching) Operating mode selector switch: SET (Teach-in mode)/ RUN (sensor mode) Teach-in push button Connection types WLL 0T-P 0 WLL 0T-N 0 WLL 0T-P0 WLL 0T-N0 WLL 0T-P WLL 0T-N See chapter Accessories Cables and connectors ounting systems Fibre-optic cables -pin, -pin, NC l mm brn blu blk L+ SENSICK CATALOGUE

12 WLL 0T Technical data WLL 0T- P P 0 P0 N N 0 N0 Suitable fibre-optic cable LL plastic fibre-optic cables Scanning range Dependent on fibre-optic cable used Recommended operating ranges mm (through-beam system) (with auxiliary lens mm) Recommended operating distance mm ) (proximity system) Sensitivity setting Automatically, by Teach-in button ode switch at pos. SET ) ode selector switch position SET Teach-in button active position RUN Teach-in button inactive ) Light source ), light type LED, visible red light Light spot diameter LL Dependent on scanning range Dispersion angle LL fibre-optic cable Approx. ) Supply voltage V ) S V DC Ripple ) 0% Current consumption ) 0 ma Switching outputs PNP: open collector: NPN: open collector: Output current I A max. 00 ma Light receiver, switching type Dark-/light-switching ) Response time 0) 0. ms Switching frequency max. ) 000/s Time delay t ( delay) 0 ms fix, selectable by sliding switch Connection types cable ) PVC, m; x 0. mm, l.0 mm plug, -pin plug, -pin Circuit protection ) A, B, C, D VDE protection class Enclosure rating IP 0 Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable m Approx. 0 g with plug, -pin/-pin Approx. 0 g Housing material ABS ) Object with 0 % remission (based on standard white to DIN 0) ) Teach-in active ) Equipment in sensor mode ) Average service life 00,000 h at T A = + C ) See LL data for deviations ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load ) By sliding switch 0) With light/dark ratio : without time delay ) With resistive load ) Do not bend below 0 C ) A = V s connections reverse-polarity protected B= Inputs/outputs reverse-polarity protected C = Interference suppression D= Outputs overcurrent and short-circuit protected Function diagram WLL 0T Standard WLL 0T in sensor mode Operating mode selector switch in RUN mode (after setting the switching threshold by means of Teach-in). Orange LED display: lights up if switching output is active. Dependent on setting of light/ dark selector switch. Green LED display: lights up if light received is < 0. or >. (based on the switching threshold, switching threshold = ). LED display in Teach-in mode: see Teach-in page t 0 ms Light received >. Switching threshold () Light received < 0. Switching output (light-switching) Switching output (dark-switching) Order information Type WLL 0T-P WLL 0T-P 0 WLL 0T-P0 WLL 0T-N WLL 0T-N 0 WLL 0T-N0 Order no Indicator LED, green SENSICK CATALOGUE

13 WLL 0T, green light, mark sensors DC Scanning range mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... mm. Proximity systems Green sender LED Ideal for recognition of red marks, contrasts or parts Commissioning by teach-in. ø. approx. 00 approx R Adjustments possible WLL 0T-P WLL 0T-P0 WLL 0T-N WLL 0T-P 0 WLL 0T-N 0 DLY L. D. SET RUN 0 WLL 0T-N0 0 LED sender, installation of LL fibre-optic cable (sender fibre) Receiver, installation of LL fibre-optic cable (receiver fibre) Protective hood, can be raised at both ends, removable ounting bracket, included in delivery (see Accessories) Orange LED indicator, lights up when switching output is active Green LED reception indicator, lights up when light received is < 0. or >. (switching threshold = ) delay selector switch: DLY (on)/, 0 ms fixed Selector switch: L. (light-switching)/ D. (dark-switching) Operating mode selector switch: SET (Teach-in mode)/ RUN (sensor mode) Teach-in push button Connection types WLL 0T-P 0 WLL 0T-N 0 WLL 0T-P0 WLL 0T-N0 WLL 0T-P WLL 0T-N See chapter Accessories Cables and connectors ounting systems Fibre-optic cables -pin, -pin, NC l mm brn blu blk L+ 0 SENSICK CATALOGUE

14 WLL 0T Technical data WLL 0T- P P 0 P 0 N N 0 N 0 Suitable fibre-optic cable LL plastic fibre-optic cables Scanning range Dependent on fibre-optic cable used Recommended operating ranges mm (through-beam system) (with auxiliary lens mm) Recommended operating distance 0... mm ) (proximity system) Sensitivity setting Automatically, by Teach-in button ode switch at pos. SET ) Additional fine alignment, manual Optional ) Black & white resolution ) grey levels ode selector switch position SET Teach-in button active position RUN Teach-in button inactive ) Light source ), light type LED, visible green light Light spot diameter LL Dependent on scanning range Dispersion angle LL fibre-optic cable Approx. ) Supply voltage V ) S VDC Ripple ) 0 % Current consumption ) 0 ma Switching outputs PNP: open collector: NPN: open collector: Output current I A max. 00 ma Light receiver, switching type Dark/light switching 0) Response time ) 0. ms Switching frequency max. ) 000/s Time delay t ( delay) 0 ms fix, selectable by sliding switch Connection types cable ) PVC, m; x 0. mm, l.0 mm plug, -pin plug, -pin Circuit protection ) A, B, C, D VDE protection class Enclosure rating IP 0 Ambient temperature T A Operation C...+ C Storage 0 C...+0 C Weight with cable m Approx. 0 g with plug, -pin Approx. 0 g Housing material ABS ) Object with 0 % remission (based on standard white to DIN 0) ) Teach-in active ) With LL -DT0 proximity fibre-optic cable, scanning distance mm ) Equipment in sensor mode ) Average service life 00,000 h at T A = + C ) See LL data for deviations ) Limit values ) ay not exceed or fall short of V S tolerances ) Without load 0) By sliding switch ) With light/dark ratio : without time delay ) With resistive load ) Do not bend below 0 C ) A=V s connections reverse-polarity protected B = Inputs/outputs reverse-polarity protected C = Interference suppression D = Outputs overcurrent and shortcircuit protected Function diagram WLL 0T standard WLL 0T in sensor mode Operating mode selector switch in RUN mode (after setting the switching threshold by means of Teach-in). Orange LED display: lights up if switching output is active. Dependent on setting of light/ dark selector switch. Green LED display: lights up if light received is < 0. or >. (based on the switching threshold, switching threshold = ). LED display in Teach-in mode: see Teach-in page t 0 ms Light received >. Switching threshold () Light received < 0. Switching output (light-switching) Switching output (dark-switching) Order information Type Order no. WLL 0T-P 0 WLL 0T-P 0 0 WLL 0T-P WLL 0T-N 0 WLL 0T-N 0 0 WLL 0T-N 0 0 Indicator LED, green SENSICK CATALOGUE

15 WLL 0T Photoelectric switches with fibre-optic cable, Teach-in Functions Teach-in button Sensitivity adjustment by pressing a button. No special photoelectric switch knowledge necessary. Only active when ODE selector switch is in the SET position (manipulation protection). Switching selector switch L.: light-switching. D.: dark-switching. Either in NPN or PNP. Connection type Either, -pin/-pin equipment plug or m connection cable. Teach-in mode selector switch Separate from other operating mode selector switches, therefore simple to operate, no double functions. SET : WLL 0T in manual Teach-in mode. Optimum switching point setting by simply pressing a botton (once or twice). RUN : The taught-in switching threshold and switching hysteresis are saved in the EEPRO. Accidental change of the taught-in parameter is not possible. After seconds the WLL 0T operates in the sensor mode. The saved Teach-in values are retained for an unlimited period of time even if the voltage is interrupted for a longer time. delay t off For switching output. Also switchable, 0 ms fixed. Enables the control unit to detect very short events. Protective hood Both sides can be opened up, easy to remove. Easy locking. Also used to check correct fibreoptic cable locking (protective hood cannot be shut otherwise). ounting system WLL 0T ounting by simply clipping onto profile mounting rail. (ounting bracket included in delivery). LED indicators orange, green Teach-in mode: Signalling Teach-in sequence Constantly flashing: Teach-in error Constantly lit: Teach-in OK. Sensor mode: Orange LED: switching output active Green LED: receiver signal >. or < 0.; (switching threshold = ). Sender LED: Either red or green LED (see selection table) Red LED: Ideal for all standard applications (high transmission power, large ranges), also for mark detection. Warning: not possible to detect red marks with red light. Green LED: Ideal for recognition of red marks. μ-prozessor controlled, with EEPRO: Permanent retention of taught-in switching threshold and hysteresis even if voltage is interrupted for a longer period of time. Snap-in connector for fibre-optic cable Fibre-optic cable mounting Release fibre-optic cable: snap closure in horizontal position. Insert the fibre-optic cable. Lock the fibre-optic cable: closure in vertical position. Removing fibre-optic cable Release the fibre-optic cable: put the snap closure in a horizontal position. Pull out the fibre-optic cable. Fibre-optic cable receptacle fibre-optic cable (sender). fibre-optic cable (receiver). Suitable fibre-optic cable: LL series plastic fibre-optic cable (see description of the many LL variants). SENSICK CATALOGUE

16 WLL 0T, Teach-in handling. Accurate sensitivity setting (by pressing button twice); WLL 0T Teach-in steps Positioning the object in the light path Proximity Through-beam Proximity Through-beam system system system system START Teach-in Parts in light path Remove parts from light path Reset: STOP Sensor mode anual Teach-in SET Press Teach-in button > s Press Teach-in button > s SET RUN RUN ode switch in SET position Press Teach-in button > sec Orange LED indicator lights Press Teach-in button > sec Green LED indicator lights ode switch in RUN position This operating mode is suitable for all applications: large ranges, precise switching points, low hysteresis, transparent objects and contrast marks. The WLL 0T automatically optimizes the switching threshold and hysteresis by means of a μ-processor and saves these values permanently in the EEPRO. No special experience with opto-electronic components is necessary. The Teach-in button is pressed twice. Applications: Through-beam system: All standard applications, even thin and transparent objects are detected. Proximity system: All standard applications, strong background interference, small or dark target objects, simple marks with contrast differences.. Accurate positioning of parts or switching positions (by pressing button once); WLL 0T Teach-in steps Positioning the object in the light path Proximity system Through-beam system START Teach-in Parts accurately positioned in light path Reset: STOP Sensor mode anual Teach-in SET Press Teach-in button > s SET RUN RUN ode switch in SET position Press Teach-in button>sec, orange LED indicator lights ode switch in RUN position This operating mode is particulary suitable for accurate positioning tasks. After positioning the object in the desired switching position, the WLL 0T automatically optimizes the switching threshold and hysteresis by means of a μ-processor and saves the values permanently in the EEPRO: No special experience with opto-electronic components is necessary. The Teach-in button is pressed once. Applications: Through-beam system: Accurate positioning of parts. Proximity system: Accurate positioning of parts, positioning of contrast marks SENSICK CATALOGUE

W 160: Miniature series for optimum solutions

W 160: Miniature series for optimum solutions W 0 Photoelectric switches Photoelectric proximity switches, BGB Photoelectric proximity switches, energetic W 0: iniature series for optimum solutions Photoelectric reflex switches Through-beam photoelectric

More information

W150: Miniature photoelectric switch series with completely integrated electronics

W150: Miniature photoelectric switch series with completely integrated electronics Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam

More information

W 27-2: The photoelectric switch series with expanded possibilities

W 27-2: The photoelectric switch series with expanded possibilities W - Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W -: The photoelectric switch series with expanded possibilities metres

More information

intelligent solutions

intelligent solutions Lichtschranken W 8- Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W 8-: Integrated stateof-the-art technology

More information

LUT Luminescence scanners: Seeing what no-one else can

LUT Luminescence scanners: Seeing what no-one else can LUT Luminescence scanners Luminescence scanners LUT Luminescence scanners: Seeing what no-one else can Special features: A semi-conductor light source is used in the LUT series no lamp change required.

More information

W 260: Standard photoelectric switch series for a broad range of applications

W 260: Standard photoelectric switch series for a broad range of applications W 0 Photoelectric switches Photoelectric proximity switches, BGS Photoelectric proximity switches, energetic Photoelectric reflex switches W 0: Standard photoelectric switch series for a broad range of

More information

W 36: Mastering complex tasks reliably

W 36: Mastering complex tasks reliably Lichtschranken W Photoelectric Baureihe switches WL - Photoelectric proximity switches, BGS Photoelectric reflex switches W : astering complex tasks reliably Through-beam photoelectric switches for temperatures

More information

W 2: Subminiature photoelectric switch series: extremely small and extremely strong

W 2: Subminiature photoelectric switch series: extremely small and extremely strong Photoelectric proximity switches BGS Photoelectric proximity switches energetic, (V optics) Photoelectric reflex switches Through-beam photoelectric switches W : Subminiature photoelectric switch series:

More information

W160T: With the smallest LED light spot

W160T: With the smallest LED light spot W0T: With the smallest LED light spot BGS Photoelectric proximity switches Photoelectric proximity switches mark sensor Photoelectric proximity switches energetic Photoelectric reflex switches SSystem

More information

W 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability

W 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability Photoelectric proximity switches, FGS Photoelectric reflex switches Through-beam photoelectric switches W -: Incorporated application Know-how, expanded functionality, high level of equipment availability

More information

V180-2 M18 Cylindrical Photoelectric Sensor Series

V180-2 M18 Cylindrical Photoelectric Sensor Series D ata S h e e t V80-8 Cylindrical Photoelectric Sensor Series A rounded concept, not only economically. Cylindrical photoelectric switches offer the benefits of very fast commissioning and compact design.

More information

BOS 73K... BOS 74K...

BOS 73K... BOS 74K... BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor

fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor ONLINE DATA SHEET www.mysick.com fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor WLL180T-P434 fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor Model Name > WLL180T-P434 Part

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

photoelectric highlights www.automation.datalogic.com

photoelectric highlights www.automation.datalogic.com photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The

More information

Electrical connection

Electrical connection (I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!

More information

For accurate positioning in warehouse and conveying areas

For accurate positioning in warehouse and conveying areas TECHNICAL DESCRIPTION DMP Position finder For accurate positioning in warehouse and conveying areas AUDIN - 8, avenue de la malle - 170 Saint Brice Courcelles - Tel : 0..0.0.1 - Fax : 0..0.8.0 - Web :

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M. Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of

More information

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6 L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution

More information

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor

D ATA S H E E T. DT50 Laser class 1. Laser distance sensor D ATA S H E E T DT50 Laser class 1 Laser distance sensor DT50 Distance sensor Laser class 1 State-of-the-art time of flight technology for fast and accurate measurement results (range up to 10 m) Quick

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

technical data (according to IEC 60947-5-2)

technical data (according to IEC 60947-5-2) Photoelectric sensors: Series 3#30 & 3#31 ü Complete miniature sensor series mm in rugged Crastin housings ü Shock & vibration resistant due to fully vacuum-potted electronics ü Diffuse sensors with precise

More information

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration

More information

Photoelectric sensors W100, Photoelectric proximity sensor, energetic

Photoelectric sensors W100, Photoelectric proximity sensor, energetic ONLINE DATA SHEET www.mysick.com Photoelectric sensors W100, Photoelectric proximity sensor, energetic WT100-P4439 Photoelectric sensors W100, Photoelectric proximity sensor, energetic Model Name > WT100-P4439

More information

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted

More information

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics

Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics ONLINE DATA SHEET www.mysick.com Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics VL180-2P42436 Photoelectric sensors V180-2, Photoelectric retro-reflective sensor,

More information

ONLINE DATA SHEET. www.mysick.com. Contrast sensors KTM KTM-WP11181P

ONLINE DATA SHEET. www.mysick.com. Contrast sensors KTM KTM-WP11181P ONLINE DATA SHEET www.mysick.com Contrast sensors KTM KTM-WP11181P Contrast sensors KTM Model Name > KTM-WP11181P Part No. > 1062199 At a glance Established mini housing High grayscale resolution Increased

More information

Universal or individual application solutions. WLL190T-2. Sensor Configuration for Individual Applications

Universal or individual application solutions. WLL190T-2. Sensor Configuration for Individual Applications MANUAL Universal or individual application solutions. Fast and reliable programming menu driven and at the push of a button: sensor properties and parameters are individually determined directly on the

More information

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions

More information

Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010

Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010 Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00 Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics

More information

Universal Voltage Terminal Photoelectric E3JM

Universal Voltage Terminal Photoelectric E3JM Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or

More information

Color sensors CS8, CS8-1

Color sensors CS8, CS8-1 ONLINE DATA SHEET www.mysick.com Color sensors CS8, CS8-1 CS81-P1112 Color sensors CS8, CS8-1 Model Name > CS81-P1112 Part No. > 1028224 At a glance One (CS8-1) or four (CS8-4) colors can be saved 12.5

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Smart Sensing Solutions Since 1954

Smart Sensing Solutions Since 1954 Smart Sensing Solutions Since 1954 X-tremely High Speed Photoelectric Registration Sensor 800-237-0946 ttco.com 813-886-4000 Photoelectric Registration Sensor The SMARTEYE X-MARK TM is the fastest, most

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Overview. Application Areas. DMP Position Finder

Overview. Application Areas. DMP Position Finder T E C N I C A D E S C R I P T I O N DMP Position Finder AUDIN - 8, avenue de la malle - 5170 Saint Brice Courcelles - Tel : 0.6.04.0.1 - Fax : 0.6.04.8.0 - Web : http: www.audin.fr - Email : info@audin.fr

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed P r o d u C t i n f o r m at i o n The new generation: WLL180T photoelectric sensor with fiber-optic cable Around the corner at High Speed WLL180T: World-class performance and scanning range SICK has been

More information

Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012

Operating instructions Optical distance sensor O1D100 O1D103 704991 / 00 08 / 2012 Operating instructions Optical distance sensor UK O1D100 O1D103 704991 / 00 08 / 2012 Contents 1 Preliminary note4 1.1 Symbols used 4 1.2 Warning signs used 4 2 Safety instructions 4 3 Functions and features

More information

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs 857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ABB i-bus EIB Logic Module LM/S 1.1

ABB i-bus EIB Logic Module LM/S 1.1 Product Manual ABB i-bus EIB Logic Module LM/S 1.1 Intelligent Installation System Contents page 1 General... 3 1.1 About this manual... 3 1.2 Product and functional overview... 3 2 Device technology...

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

Fiber-Optic Photoelectric Sensor

Fiber-Optic Photoelectric Sensor Fiber-Optic Photoelectric Sensor High Performance Amplifier Has Fast Response Time, Longer Sensing Distance and Self-Diagnostic Functions Ultra fast 20 µsec. response time (-F) Extended sensing distance

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Mounting holes. (threaded M4) Switching state indication (5 yellow LEDs)

Mounting holes. (threaded M4) Switching state indication (5 yellow LEDs) SI-COLO Series SI-COLO4-LWL-SP (12 bit A/D conversion) - Big measuring range: typ. 2 mm... 25 mm (with optical fiber bundle Ø 2.5 mm or gap 6 mm x 1 mm) - Large assortment of optical fibers available -

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause

More information

How To Use An Od Max Sensor System For Distance Measurement

How To Use An Od Max Sensor System For Distance Measurement OD Max: Highly precise distance measurement thickness or the evenness can be achieved. This is due to the in the system integrated arithmetical functions. D T SHEET Displacement TThe OD Max is an highly

More information

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information

More information

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

crm+25/d/tc/e Extract from our online catalogue: Current to: 2015-10-26

crm+25/d/tc/e Extract from our online catalogue: Current to: 2015-10-26 Extract from our online catalogue: crm+25/d/tc/e Current to: 2015-10-26 microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de

More information

MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY

MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY MAIN CATALOGUE MAKING SENSE OF TECHNOLOGY MAKING SENSE OF TECHNOLOGY TABLE OF CONTENTS Corporate Profile Remote Photoelectric Systems Self-Contained Photoelectric Systems Self-Contained Light Curtain Systems

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119 EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70

More information

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING

1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING 1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: regulateurs@regulateurs-europa.com 1115 4G

More information

Multi-function Card. 1 Description. 2 Technical data ESSK 107. 1.1 General. 1.2 Application example

Multi-function Card. 1 Description. 2 Technical data ESSK 107. 1.1 General. 1.2 Application example Multi-function Card ESSK 107 semiconductor output stages 3 power outputs 1 current measurement input 2 analogue / digital inputs 1 digital input 5 adjustments power supply 12... 30 V 1 Description 1.1

More information

ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO

ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO ONLINE DATA SHEET WT34-R220 W34 A B C D E F WT34-R220 W34 Illustration may differ Ordering information Type Part no. WT34-R220 1019233 Other models and accessories www.sick.de/w34 H I J K L M N O P Q R

More information