MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver.

Size: px
Start display at page:

Download "MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver."

Transcription

1 -TVI -RI D.C. MEASURING CONVERTER Converter for D.C. Current and/or Voltage measurement. Direct connection to D.C. mains rating up to 4 kvcc. Fully isolated multi-voltage power suppy. Fiber optic connection between HV transducer and LV reciving unit. Measurement channel fully diagnosed -RV General Characteristics The transducer provide a measurement of current or voltage fully isolated and safe. The transducer includes three components: Transmitter, Riceiver, Fiber Optic. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver. The test voltage isolation between inputs and power supply is equal to 0kV 50Hz min. Voltage Transmitter -TV Converter for Voltage measurement direct connection to D.C. line up to 4000V (voltage divider inside) /A-TV Selfpowered version directly from the main. Current Transmitter -TI Transmitter for measuring current, directly connected to the high voltage line through normal shunt (input mV). Current/Voltage Transmitter -TVI Transmitter current and voltage in a single unit directly connected to the high voltage line (max 4000Vcc) through the shunt. MHIT/A-TVI Selfpowered version directly from the main. Riceiver The Receiver connected via optical fiber to the transmitter has three configurable linear analog outputs, - one relay output for alarm and internal fault. As option Undervoltage of Overcurrent level with relay output, display and push-buttons for paraneterization of the device M0-ING-Rev.6 Current and Voltage Receiver -RV voltage measurements -RI current measurements Fiber Optic The optical fiber used for the connection between the transmitter and receiver (equipped with ST connectors) must have the following characteristics: Plastic: 00u HCS - Glass: 6.5/5 The standard length of the optical fiber is 5 meters. (other lengths available on request).

2 Wiring Diagram - Standard version with external auxiliary power supply I V -TV -TVI -TI ALARM EST. RESET ALARM EST. RESET -RV (*) (*) -RI M0-ING-Rev.6 (*) The figure shows the version with optional display

3 Wiring Diagram - Selfpowered Version /A-T-V /A-T-I --- /A-T-VI ALARM EST. RESET ALARM EST. RESET M0-ING-Rev.6! N.B. : STANDARD VERSION WITH SHUNT ON POSITIVE POLARITY POLARITY WHERE THE SHUNT IS CONNECTED MUST BE ADVISED WHEN ORDERING

4 4 Characteristics Voltage Transmitter -TV Directly connected to the H.V. line via internal voltage divider Power supply voltage () N.D. (4) (0)Vac ±0% () ( 70)Vdc () (85 60)Vdc (5) (0)Vac ±0% Rated input voltage () 00Vdc; () 750Vdc; () 000Vdc; (4) 500Vdc; (5) 000Vdc; (6) 4000Vdc. Input Impedance 0 MW Outputs Fiber Optic free running serial output (type = ST-ST) Fiber Optic standard length 5m (max. 50m) Measurement dynamic range 0 ±Vn Measurement accuracy 0.% Vn (-0 to +70) C Sampling frequency. khz Response time 0.5 msec. (compensated) Enclosure Material: BMCRF9 protection degree IP55 Connessioni Connection terminals Bolt A vite type (M6) terminals per ingressi (M6) di for misura inputs; / ST per for F.O. the / F.O. Morsetti ;.5mm per Screw type.5 mm for Power supply consumption 5 VA Characteristics Voltage Transmitter /A-TV - Selfpowered Directly connected to the H.V. line via internal voltage divider Power supply voltage ( )Vdc Rated input voltage 4000Vdc. Input Impedance 0 MW (measuring input) Outputs Fiber Optic free running serial output (type = ST-ST) Fiber Optic standard length 5m (max. 50m) Measurement dynamic range 0 ±Vn Measurement accuracy 0.% Vn (-0 to +70) C Sampling frequency. khz Response time 0.5 msec. (compensated) Enclosure Selfextinguishing FGRP Connessioni Bolt type (M6) of terminals for inputs / ST for F.O. M0-ING-Rev.6

5 5 Characteristics Current Transmitter -TI Directly connected to the H.V. line across a normal measuring shunt Power supply voltage () N.D. (4) (0)Vac ±0% () ( 70)Vdc () (85 60)Vdc (5) (0)Vac ±0% Rated input current () 60 mvdc; () 80 mvdc; () 00 mvdc; (4) others on request. Outputs Fiber Optic free running serial output (type = ST-ST) Fiber Optic standard length 5m (max. 50m) Measurement dynamic range () 0 ± In; () 0 ±0 In (x DIA / U-MLEs) - (% for auxiliary output 4) Measurement accuracy 0.% In (-0 to +70) C Sampling frequency. khz Response time 0.5 msec. (compensated) Diagnostic of Shunt's interruption Signalization via Fiber Optic Enclosure Material: BMCRF9 protection degree IP55 Connessioni Connection terminals Bolt A vite type (M6) terminals per ingressi (M6) di for misura inputs; / ST per for F.O. the / F.O. Morsetti ;.5mm per Screw type.5 mm for Power supply consumption 5 VA Characteristics Current Transmitter /A-TI - Selfpowered Directly connected to the H.V. line across a normal measuring shunt. Power supply voltage ( )Vdc Rated input current () 60 mvdc; () 80 mvdc; () 00 mvdc; (4) others on request. Outputs Fiber Optic free running serial output (type = ST-ST) Fiber Optic standard length 5m (max. 50m) Measurement dynamic range () 0 ± In; () 0 ±0 In (x DIA / U-MLEs) Measurement accuracy 0.% In (-0 to +70) C Sampling frequency. khz Response time 0.5 msec. (compensated) Diagnostic of Shunt's interruption Signalization via Fiber Optic Enclosure Selfextinguishing FGRP Connessioni Connection terminals Bolt A vite type (M6) (M6) per terminals ingressi di for misura inputs / ST / ST per for F.O. / Morsetti.5mm per Shunt Position () on positive; () on negative M0-ING-Rev.6

6 6 Characteristics Voltage Receiver (-RV) - Without Display Power supply consumption 8VA Power supply voltage () N.D. (4) (0)Vac ±0% () ( 70)Vdc (5) (0)Vac ±0% () (85 60)Vdc Measuring input Fiber Optic transmitter -TV Outputs (configurable on request) current loop outputs; Max. output power 0.7VA.5V Output accuracy 0.% full scale (-0 to +70) C Response time < 0.5 msec. Sampling frequency. khz Mesurement display Led "ON" and "DIAG" Diagnostic alarm relay Contact C/O. (Relay normally energized) Deenergized for Internal Fault (Transmitter, Receiver, F.O. interruption, failure) Relay pick-up time Enclosure Insulation Connection Terminals < 00 msec. ABS protection degree IP4 500 Vac for min. power supply / output 500 Vac for min. relay / output Bolt type terminals (.5 mmq) - ST for Fiber Optic Standard output setting range Output (terminals -) Output (terminals -4) Output (terminals 5-6) (-) 0 ±0 (0)mA º 0 ±Vn (.5Vn) (-) 4 0 (8)mA º 0 ±Vn (.5Vn) (-) 0 ±0 (0)mA º 0 ±Vn (.5Vn) (-) 4 0 (8)mA º 0 ±Vn (.5Vn) (-) 0 ±0 (0)mA º 0 ±Vn (.5Vn) (-) 4 0 (8)mA º 0 ±Vn (.5Vn) (-) 0 ±0 (5)mA º 0 ±Vn (.5Vn) (-) 0 ±0 (5)mA º 0 ±Vn (.5Vn) (-) 0 ±0 (5)mA º 0 ±Vn (.5Vn) Fiber Optic Fibra Ottica DIAGNOSTIC CLOSE=NORMAL OPERATION OPEN=FAULT DIAGNOSTICA CHIUSO=FUNZ.NORMALE APERTO=GUASTO M0-ING-Rev.6 Alim. Aux. 7 6

7 7 Version with Display and Alarm (Optional) Display Alarm level Display LED (Vnom) LED (ALARM) Diagnostic alarm relay Undervoltage alarm Undervoltage alarm Reset 4 digit, 7 segment (measurement V) "On" in programming mode for display full scale (Nominal Primary voltage of the converter) "On" in programming mode for undervoltage alarm level Contact N.O. (Relay normally energized) Deenergized for Internal Fault (Transmitter, Receiver, F.O. interruption, Power Suppy faillure) Alarm level setting range 0 Vn, step 0V Contact N.O. (Relay normally deenergized) Manual (ENTER key) or Remote Automatic if terminals of Reset Input are shorted Fiber Optic Fibra Ottica DIAGNOSTIC CLOSE=NORMAL OPERATION OPEN=FAULT DIAGNOSTICA CHIUSO=FUNZ.NORMALE APERTO=GUASTO 7 ALARM 8 ALLARME Alim. Aux RESET RIARMO M0-ING-Rev.6

8 8 Characteristics Current Receiver (-RI) - Without Display Power supply consumption 8VA Power supply voltage () N.D. (4) (0)Vac ±0% () ( 70)Vdc (5) (0)Vac ±0% () (85 60)Vdc Measuring input Fiber Optic transmitter -TI Outputs (configurable on request) current loop outputs; Max. output power 0.7VA.5V Output accuracy 0.% full scale (-0 to +70) C Response time < 0.5 msec. Sampling frequency. khz Mesurement display Led "ON" and "DIAG" Diagnostic alarm relay Contact C/O. (Relay normally energized) Deenergized for Internal Fault (Transmitter, Receiver, F.O. interruption, failure) Relay pick-up time Enclosure Insulation Connection Terminals < 00 msec. ABS protection degree IP4 500 Vac for min. power supply / output 500 Vac for min. relay / output Bolt type terminals (.5 mmq) - ST for Fiber Optic Standard output setting range Output (terminals -) Output (terminals -4) Output (terminals 5-6) Output 4 (terminals 7-8) Optional (-) 0 ±0 (40)mA º 0 ±In ( In) (-) 4 0 (6)mA º 0 ±In ( In) (-) 0 ±0 (40)mA º 0 ±In ( In) (-) 4 0 (6)mA º 0 ±In ( In) (-) 0 ±0 (0)mA º 0 ±In ( In) (-) 0 ±0 (40)mA º 0 ±In ( In) (-) 4 0 (6)mA º 0 ±In ( In) (4-) 4 0 ma º -0.75In +.5In (4-) 4 0 ma º 0 +.5In (4-) 4 0 ma º 0 +In (4-4) 4 0 ma º 0 +.In (-) 0 ±0 (0)mA º 0 ±In ( In) (-4) 0 ±5 (0)mA º 0 ±In ( In) (-4) 0 ±5 (0)mA º 0 ±In ( In) (-5) 0 ±0 (40)mA º 0 ±0In (0 In) (-) 0 ±0 (0)mA º 0 ±In ( In) (-4) 0 ±5 (0)mA º 0 ±In ( In) (4-5) 4 0 ma º -0.75In +0.75In (4-6) 4 0 ma º -In +In (4-7) 4 0 ma º -In +In (4-8) 4 0 ma º -.In +.5In Fiber Optic Fibra Ottica OPTIONAL OPZIONALE M0-ING-Rev DIAGNOSTIC CLOSE=NORMAL OPERATION OPEN=FAULT DIAGNOSTICA CHIUSO=FUNZ.NORMALE APERTO=GUASTO Alim. Aux. 7 6

9 9 Version with Display and Alarm (Optional) Display Alarm level Display LED (ka) LED (A) LED (Inom) LED (ALARM) Diagnostic alarm relay Overcurrent Alarm Overcurrent Alarm Reset 4 digit, 7 segment (measurement ka) Measurement displayed in ka Measurement displayed in A "On" in programming mode for display full scale (Shunt's Primary Amp) "On" in programming mode for overcurrent alarm level Contact N.O. (Relay normally energized) Deenergized for Internal Fault (Transmitter, Receiver, F.O. interruption, failure) Alarm level setting range 0 In, step 0A Contact N.O. (Relay normally deenergized) Manual (ENTER key) or Remote Automatic if terminals of RESET INPUT are shorted Fiber Optic Fibra Ottica DIAGNOSTIC CLOSE=NORMAL OPERATION OPEN=FAULT DIAGNOSTICA CHIUSO=FUNZ.NORMALE APERTO=GUASTO 7 ALARM 8 ALLARME Alim. Aux RESET RIARMO M0-ING-Rev.6

10 0 Overall Dimensions - Transmitter (mm) 5 9 5,5 0 Ø M6 5 -TVI , ,5 0 Ø M6 -T , Overall Dimensions - Receiver (mm) I -RI ka A Inom Alarm SELECT ENTER VERSION "O" with OPTIONS M0-ING-Rev R (*) 7 8 ON DIAG STANDARD VERSION (*) 4 - OPTIONAL

11 Reference Standard CE Directive - EN50 - IEC6055 Dielectric test voltage IEC cat IV - kv Impulse test voltage EN50 IEC EN50 (EN504- cat OV4-8.5kV) cat IV - 5kV (EN504- cat OV4-40kV) Enviromental Rif.Std. (IEC 60068) Operation ambient temperature EN class C (k5) -0 C / +55 C Environmental testing (Cold) (Dry heat) (Change of temperature) (Damp heat, steady state) Resistance to vibration Resistance to vibration and shock (bump-shock) Sismatic stress resistance CE EMC Compatibilità Electromagnetic emission Conducted disturbances immunity test Radiated electromagnetic field immunity test Electrostatic discharge test Power frequency magnetic test Conducted disturbances immunity test IEC IEC IEC IEC IEC IEC IEC class class class -0 C ; 6h +55 C ; U.R.<=5%; 6h +55 C ; -0 C ; h +40 C ; U.R.<=9%; 96h Hz ; g 0 g - 5 g g (xy), g (z) EN MHz (tab EN5008-) A EN550 class B MHz (tab EN5008-) 0V A EN A.5. level MHz 80%AM 0V/m B IEC EN5008- level 900MHz/00Hz 0V/m A EN5040, EN5004 EN5008- ENV5040 EN A.. IEC EN A.4. IEC EN5008- IEC level level 6kV contatto / 8kV aria B level 5 continui 00 A/m 50/60Hz A level (80 ±5)% AM khz sinwave A Damped oscillatory magnetic field EN A.4. level 0 A/m, 0. MHz IEC Electrical fast transient/burst (Fast Trasient) EN A.. level kv (m.c.) B IEC Dumped Oscillatory waves EN A..5 level kv (m.c.) IEC Power supply tollerance IEC class DC class AC Residual power supply EN VR 5% Surge immunity test EN A.. level 8/0ms kv (m.c.) B IEC Voltage interruptions EN A..5 0ms IEC Voltage ripple EN A..4 A=B IEC Characteristics Accuracy at reference value of influencing factors Class 0. Average power supply consumption TX 5 VA Average power supply consumption RX 7 VA Output relays rating 6 A; Vn = 50 V A.C. resistive switching = 500VA (400V max) make = 0 A (peak) 0,5 sec.; break = 0. A, 0 Vcc, 6 L/R = 40 ms ( op.) Meccanichal life 0 op M0-ING-Rev.6

12 Transmitter Voltage - Order Code : -TV TV _ Type Empty = /A = Selfpowered (/A-TV-...) 0 = Selfpowered = N.D. = ( 70)Vdc = (85 60)Vdc 4 = 0Vac ±0% 6 Rated Input Voltage = 00 Vdc = 750 Vdc = 000 Vdc 4 = 500 Vdc 5 = 000 Vdc 6 = 4000 Vdc 5 = 0Vac ±0% Transmitter Current - Order Code : -TI TI _ Type Empty = 0 = Selfpowered = N.D. /A = Selfpowered = ( 70)Vdc (/A-TV-...) = (85 60)Vdc 4 = Specify 4 = 0Vac ±0% 5 = 0Vac ±0% Receiver Voltage - Order Code : -RV - ()-()-()- -RV _ ( _ ) Type Output O = with Options - = (0 ±0) ma (-RV-O-...) - = (4 0) ma - = (0 ±0) ma Receiver Current - Order Code : -RI - ()-()-()-(4)- -RI _ Type ( _ ) Output ( _ ) Output O = with Options - = ( 0 ±0) ma - = ( 0 ±0) ma (-RV-O-...) - = (4 0) ma - = (0 ±0) ma - = (4 0) ma - = (0 ±0) ma Rated Input Current = 60 mvdc = 80 mvdc = 00 mvdc -4 = (0 ±5) ma -4 = (0 ±5) ma -5 = (0 ±0) ma (x DIA / U-MLEs) Fiber Optic - Order Code : -FO - -FO Fiber Optic = 5 mt (standard) = mt (specifiy length) ST - Connector ( _ ) Output - = ( 0 ±0) ma - = (4 0) ma - = (0 ±0) ma ( _ ) Output - = ( 0 ±0) ma - = (4 0) ma - = (0 ±0) ma -4 = (0 ±5) ma Dynamic range = ( 0 ±) In = (0 ±0) In (x DIA / U-MLEs) ( _ ) Output - = ( 0 ±0) ma - = (4 0) ma - = (0 ±0) ma Selfpowered version SHUNT connection = Positive = Negative ( 4_ ) Output = None 4- = ( ) (In) 4- = (0 +.5) (In) 4- = (0 +) (In) 4-4 = (0 +.) (In) 4-5 = ( ) (In) 4-6 = (- +) (In) 4-7 = (- +) (In) 4-8 = (-. +.5) (In) = N.D. = ( 70)Vdc = (85 60)Vdc 4 = 0Vac ±0% 5 = 0Vac ±0% = N.D. = ( 70)Vdc = (85 60)Vdc 4 = 0Vac ±0% 5 = 0Vac ±0% M0-ING-Rev.6 55 mm The performances and the characteristics reported in this document are not binding and can modified at any moment without notice Microelettrica Scientifica S.p.A Buccinasco (MI) - Via Lucania, Italy Tel Fax sales.relays@microelettrica.com

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Trip circuit supervision relay. Type RXTCS

Trip circuit supervision relay. Type RXTCS Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Disturbance Recoder SPCR 8C27. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

Capacitor Protection Relay SPAJ 160 C. Product Guide

Capacitor Protection Relay SPAJ 160 C. Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Relion 605 series. Self-powered feeder protection REJ603 Product Guide Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...

More information

7.5 Watt AC-DC Switch Power Supply

7.5 Watt AC-DC Switch Power Supply MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better

More information

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new

More information

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

FREJA 300 Relay Testing System

FREJA 300 Relay Testing System Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT

More information

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch

More information

Arc Terminator Active Arc-Resistant Switchgear

Arc Terminator Active Arc-Resistant Switchgear Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000 Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

LAUBE TECHNOLOGY DRY REED RELAYS

LAUBE TECHNOLOGY DRY REED RELAYS LAUBE TECHNOLOGY DRY REED RELAYS CONTACT FORM CURRENT PART SERIES PAGE #'S (1A) SPST-NO 1 AMP D41A...0L 147~148 (Link) (1A) SPST-NO 1 AMP D71A.1.0 149~150 (Link) (1A) SPST-NO 1 AMP F51A.100 151~152 (Link)

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

60 Series - General purpose relays 6-10 A. Features 60.12 60.13

60 Series - General purpose relays 6-10 A. Features 60.12 60.13 Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac Product Description Capacitor charger power supplies from Digital Power are designed to meet the exacting requirements of medical, aesthetic, and industrial pulsed energy systems. The modular design of

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC3200 INTELLIGENT BROADBAND AMPLIFIER Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES 4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENTS S RELAYS FEATURES 28. 1.12 12..472 1.4.49 The variety of contact arrangements 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A Latching types available High

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

47000 SERIES - ELECTRONIC TRANSFORMERS

47000 SERIES - ELECTRONIC TRANSFORMERS 7000 SERIES - ELECTRONIC TRANSFORMERS MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!

More information