LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial
|
|
- Abigail Hensley
- 7 years ago
- Views:
Transcription
1 Siemens AG 010 / / SIPLUS basic versions /5 SIPLUS Pure versions /8 analog expansion modules /9 SIPLUS expansion modules Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial Siemens ST 70 N 010
2 Siemens AG 010 SIPLUS basic versions Overview The space-saving basic variants Interface for the connection of expansion modules, up to 4 digital inputs, 16 digital outputs, 8 analog inputs and analog outputs can be addressed With connection option for LOGO! text display TD (can be connected to all LOGO! 0BA6 basic versions) For further technical documentation on SIPLUS, see: Environmental conditions Ambient temperature range SIPLUS extreme -5 to +60/+70 C 1) Relative humidity 100% Dewing, condensation and icing permissible Contaminant concentration EN C4 and ISA S71.04 G1, G, G3, GX Constant load Limit value ) SO 4.8 ppm 17.8 ppm H S 9.9 ppm 49.7 ppm Cl 0. ppm 1.0 ppm HCl 0.66 ppm 3.3 ppm HF 0.1 ppm.4 ppm NH 49 ppm 47 ppm O ppm 1.0 ppm NO x 5. ppm 10.4 ppm At RH < 75%, condensation permitted Saline fog Saline fog test (EN ) Mechanically active substances Dust (suspended substance content) Dust (precipitation) Biologically active substances EN S4 4.0 mg/m h 40 mg/m h incl. conductive sand/dust ("Arizona dust") EN B Mildew growth, Fungus, excluding fauna 1) Depends on the product family ) 30 min/day SIPLUS LOGO! 4 SIPLUS LOGO! 1/4RC SIPLUS LOGO! 4RC SIPLUS LOGO! 30RC Order No. 6AG1 05-1CC00-BA6 6AG1 05-1MD00-BA6 6AG1 05-1HB00-BA6 6AG1 05-1FB00-BA6 Order No. based on 6ED1 05-1CC00-0BA6 6ED1 05-1MD00-0BA6 6ED1 05-1HB00-0BA6 6ED1 05-1FB00-0BA6 Ambient temperature range - 5 to + 70 C - 5 to + 55 C (for applications with cul approval), condensation permissible Environmental conditions Approvals Technical specifications Resistant in accordance with EN6071 to chemically (-3C4), mechanically (-3S4) and biologically (-3B) active substances and compliant with ISA S71.04 G1, G, G3, GX1). For further information, refer to Environmental conditions of SIPLUS extreme (on pg. 4/) or go to CE, cul The technical data of the standard product apply with the exception of the environmental conditions. Technical specifications 6AG1 05-1CC00-BA6 6AG1 05-1MD00-BA6 6AG1 05-1HB00-BA6 6AG1 05-1FB00-BA6 Supply voltages Rated value 1 V DC 4 V DC 115 V DC 30 V DC / Siemens ST 70 N 010
3 Siemens AG 010 SIPLUS basic versions Technical specifications (continued) Rated value (continued) permissible range, lower limit (DC) permissible range, upper limit (DC) 4 V AC 115 V AC 30 V AC permissible range, lower limit (AC) permissible range, upper limit (AC) Time of day Time switching clocks 6AG1 05-1CC00-BA6 6AG1 05-1MD00-BA6 6AG1 05-1HB00-BA6 6AG1 05-1FB00-BA6 0.4 V 10.8 V 0.4 V 100 V 8.8 V 8.8 V 8.8 V 53 V 0.4 V 85 V 6.4 V 65 V Power reserve 80 h 80 h 80 h Digital inputs Number of digital inputs Digital outputs 8; Of which 4 can be used in analog mode (0 to 10 V) 8; Of which 4 can be used in analog mode (0 to 10 V) 8 8 Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay Short-circuit protection ; electrical (1 A) No; Relay outputs Switching capacity of contacts No; with inductive load, max. 3 A 3 A 3 A with resistive load, max. 0.3 A 10 A 10 A 10 A EMC Emission of radio interference acc. to EN (limit class B) Degree of protection IP0 Standards, approvals, certificates CSA approval developed according to IEC FM approval according to VDE 0631 Marine approval UL approval Mounting Width 7 mm 7 mm 7 mm 7 mm Height 90 mm 90 mm 90 mm 90 mm Depth 55 mm 55 mm 55 mm 55 mm No; Siemens ST 70 N 010 /3
4 Siemens AG 010 SIPLUS basic versions Ordering data Order No. Order No. SIPLUS LOGO! 4 4 V DC power supply, 8x 4 V DC digital inputs, of which 4 can be used in analog mode ( V), 4x 4 V DC digital outputs, 0.3 A; 00 function blocks can be interlinked, SIPLUS LOGO! 1/4RC 1/4 V DC power supply, 8x 1/4 V DC digital inputs, of which 4 can be used in analog mode ( V), 4x 10 A relay outputs, 00 function blocks can be interlinked, SIPLUS LOGO! 4RC 4 V AC/DC power supply, 8x 4 V AC/DC digital inputs, 4x 10 A relay outputs, 00 function blocks can be interlinked, SIPLUS LOGO! 30RC 115/30 V AC/DC power supply, 8x 115/30 V AC/DC digital inputs, 4x 10 A relay outputs, 00 function blocks can be interlinked, Accessories SIPLUS LOGO! TD text display (extended temperature range C and medial load) 4-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including connecting cable LOGO! manual German English French Spanish Italian Chinese 6AG1 05-1CC00-BA6 6AG1 05-1MD00-BA6 6AG1 05-1HB00-BA6 6AG1 05-1FB00-BA6 6AG MH00-BA0 6ED AA00-0AE7 6ED AA00-0BE7 6ED AA00-0CE7 6ED AA00-0DE7 6ED AA00-0EE7 6ED AA00-0KE7 A: Subject to export regulations: AL: N and ECCN: EAR99S B: Subject to export regulations: AL: N and ECCN: EAR99T LOGO! memory card Program module for copying, with know-how protection LOGO! battery card Battery module for backing up the integral real-time clock (not LOGO! 4) LOGO! memory/battery card Combined program and battery module, with know-how protection and for backing up the integral real-time clock (not LOGO! 4) LOGO! PROM Programming device for modules 6ED DA00-0BA0 6ED XA00-0BA0 6ED DA00-0BA0 6AG AA01-0BA6 LOGO!Soft Comfort V6.0 A 6ED BA0-0YA0 For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO!Soft Comfort V6.0 Upgrade Upgrade from V1.0 to V6.0 LOGO! PC cable For program transfer between LOGO! and the PC A 6ED CA0-0YE0 6ED AA00-0BA0 LOGO! USB PC cable B 6ED AA01-0BA0 For transferring the program between LOGO! and PC, including driver on CD-ROM LOGO! modem cable Adapter cable for analog modem communication LOGO! Mounting set For use in a front panel with Plexiglas pane and gasket Mounting set 4 WM Mounting set 4 WM with keys Mounting set 8 WM Mounting set 8 WM with keys SIPLUS upmiter power supply unit for dependable operation of SIPLUS devices supplied by the battery of internal combustion engines 6ED CA00-0BA0 6AG AA00-0AA0 6AG AA00-0AA3 6AG AA00-0AA1 6AG AA00-0AA 6AG AA00-AA0 /4 Siemens ST 70 N 010
5 Siemens AG 010 SIPLUS Pure versions Overview Basic variants optimized for costs Interface for the connection of expansion modules, up to 4 digital inputs, 16 digital outputs, 8 analog inputs and analog outputs can be addressed With connection option for LOGO! text display TD (can be connected to all LOGO! 0BA6 basic versions) For further technical documentation on SIPLUS, see: SIPLUS LOGO! 4o SIPLUS LOGO! 1/4RCo SIPLUS LOGO! 4RCo SIPLUS LOGO! 30RCo Order No. 6AG1 05-CC00-BA6 6AG1 05-MD00-BA6 6AG1 05-HB00-BA6 6AG1 05-FB00-BA6 Order No. based on 6ED1 05-CC00-0BA6 6ED1 05-MD00-0BA6 6ED1 05-HB00-0BA6 6ED1 05-FB00-0BA6 Ambient temperature range - 5 to + 70 C Environmental conditions Approvals Technical specifications - 5 to + 55 C (for applications with cul approval), condensation permissible Resistant in accordance with EN6071 to chemically (-3C4), mechanically (-3S4) and biologically (-3B) active substances and compliant with ISA S71.04 G1, G, G3, GX1). For further information, refer to Environmental conditions of SIPLUS extreme (on pg. 4/) or go to CE, cul The technical data of the standard product apply with the exception of the environmental conditions. Technical specifications Supply voltages Rated value 1 V DC 6AG1 05-CC00-BA6 6AG1 05-MD00-BA6 6AG1 05-HB00-BA6 6AG1 05-FB00-BA6 4 V DC 115 V DC 30 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) 4 V AC 115 V AC 30 V AC permissible range, lower limit (AC) permissible range, upper limit (AC) 0.4 V 10.8 V 0.4 V 100 V 8.8 V 8.8 V 8.8 V 53 V 0.4 V 85 V 6.4 V 65 V Siemens ST 70 N 010 /5
6 Siemens AG 010 SIPLUS Pure versions Technical specifications (continued) Time of day Time switching clocks 6AG1 05-CC00-BA6 6AG1 05-MD00-BA6 6AG1 05-HB00-BA6 6AG1 05-FB00-BA6 Number Power reserve 80 h 80 h 80 h Digital inputs Number of digital inputs Digital outputs 8; Of which 4 can be used in analog mode (0 to 10 V) 8; Of which 4 can be used in analog mode (0 to 10 V) 8 8 Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay Short-circuit protection ; electrical (1 A) No; Relay outputs Switching capacity of contacts No; with inductive load, max. 3 A 3 A 3 A with resistive load, max. 0.3 A 10 A 10 A 10 A EMC Emission of radio interference acc. to EN (limit class B) Degree of protection IP0 Standards, approvals, certificates CSA approval developed according to IEC FM approval according to VDE 0631 Marine approval UL approval Mounting Width 7 mm 7 mm 7 mm 7 mm Height 90 mm 90 mm 90 mm 90 mm Depth 55 mm 55 mm 55 mm 55 mm No; /6 Siemens ST 70 N 010
7 Siemens AG 010 SIPLUS Pure versions Ordering data Order No. Order No. SIPLUS LOGO! 4o 4 V DC power supply, 8x digital inputs 4 V DC, of which 4 can be used in analog mode ( V), 4x digital outputs 4 V DC, 0.3 A; without display and keyboard; 00 function blocks can be interlinked, SIPLUS LOGO! 1/4RCo 1/4 V DC power supply, 8x digital inputs 1/4 V DC, of which 4 can be used in analog mode ( V), 4x relay outputs 10 A, without display and keyboard; 00 function blocks can be interlinked, SIPLUS LOGO! 4RCo 4 V AC/DC power supply, 8 digital inputs 4 V AC/DC, 4 relay outputs 10 A, without display and keyboard; 130 function blocks can be interlinked, SIPLUS LOGO! 30RCo 115/30 V AC/DC power supply, 8x digital inputs 115/30 V AC/DC, 4 relay outputs 10 A, without display and keyboard; 00 function blocks can be interlinked, Accessories SIPLUS LOGO! TD text display (extended temperature range C and medial load) 4-line text display, can be connected to all LOGO! 0BA6 Basic and Pure versions, including connecting cable 6AG1 05-CC00-BA6 6AG1 05-MD00-BA6 6AG1 05-HB00-BA6 6AG1 05-FB00-BA6 6AG MH00-BA0 LOGO! manual German English French Spanish Italian Chinese LOGO! memory card Program module for copying, with know-how protection LOGO! battery card Battery module for backing up the integral real-time clock (not LOGO! 4) LOGO! memory/battery card Combined program and battery module, with know-how protection and for backing up the integral real-time clock (not LOGO! 4) LOGO! PROM Programming device for modules 6ED AA00-0AE7 6ED AA00-0BE7 6ED AA00-0CE7 6ED AA00-0DE7 6ED AA00-0EE7 6ED AA00-0KE7 6ED DA00-0BA0 6ED XA00-0BA0 6ED DA00-0BA0 6AG AA01-0BA6 LOGO!Soft Comfort V6.0 A 6ED BA0-0YA0 For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO!Soft Comfort V6.0 Upgrade Upgrade from V1.0 to V6.0 LOGO! PC cable For program transfer between LOGO! and the PC A 6ED CA0-0YE0 6ED AA00-0BA0 LOGO! USB PC cable B 6ED AA01-0BA0 For transferring the program between LOGO! and PC, including driver on CD-ROM LOGO! modem cable Adapter cable for analog modem communication LOGO! Mounting set For use in a front panel with Plexiglas pane and gasket Mounting set 4 WM Mounting set 4 WM with keys Mounting set 8 WM Mounting set 8 WM with keys SIPLUS upmiter power supply unit for dependable operation of SIPLUS devices supplied by the battery of internal combustion engines 6ED CA00-0BA0 6AG AA00-0AA0 6AG AA00-0AA3 6AG AA00-0AA1 6AG AA00-0AA 6AG AA00-AA0 A: Subject to export regulations: AL: N and ECCN: EAR99S B: Subject to export regulations: AL: N and ECCN: EAR99T Siemens ST 70 N 010 /7
8 Siemens AG 010 analog expansion modules Overview Expansion modules for the connection to With digital inputs and outputs, analog inputs or analog outputs Technical specifications Supply voltages Rated value 1 V DC 4 V DC Analog outputs Number of analg outputs Output ranges, voltage 0 to 10 V EMC Emission of radio interference to EN (limit class B) Environmental requirements Operating termperature 6ED MM00-0BA1 No min. 0 C max. 55 C Degree of protection IP 0 Standards, approvals, certificates CSA approval Developed to IEC1131 FM approval to VDE 0631 Marine approval UL Approval Dimensions Mounting Width Height Depth spacing units wide 36 mm 90 mm 55 mm Ordering data Order No. LOGO! AM AQ C 6ED MM00-0BA1 Supply voltage 4 V DC, analog outputs, V, 0/ ma Accessories LOGO! Manual German English French Spanish Italian Chinese LOGO! memory card for copying, with know-how protection 6ED AA00-0AE7 6ED AA00-0BE7 6ED AA00-0CE7 6ED AA00-0DE7 6ED AA00-0EE7 6ED AA00-0KE7 6ED CA00-0BA0 LOGO!Soft Comfort V6.0 A 6ED BA0-0YA0 For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO!Soft Comfort V6.0 upgrade Upgrade from V1.0 to V6.0 LOGO! PC cable For program transfer between LOGO! and the PC A: Subject to export regulations: AL: N and ECCN: EAR99S C: Subject to export regulations: AL: N and ECCN: EAR99H A 6ED CA0-0YE0 6ED AA00-0BA0 /8 Siemens ST 70 N 010
9 Siemens AG 010 SIPLUS expansion modules Overview Expansion modules for connection to With digital inputs and outputs, analog inputs, or analog outputs For further technical documentation on SIPLUS, see: SIPLUS LOGO! DM8 4 SIPLUS LOGO! AM AQ SIPLUS LOGO! DM16 4R Order No. 6AG PB00-BY0 6AG MM00-BY1 6AG NB10-BA0 Order No. based on 6ED CB00-0BA0 6ED MM00-0BA1 6ED NB10-0BA0 Ambient temperature range - 5 to + 70 C Environmental conditions - 5 to + 55 C (for applications with cul approval), condensation permissible Resistant in accordance with EN6071 to chemically (-3C4), mechanically (-3S4) and biologically (-3B) active substances and compliant with ISA S71.04 G1, G, G3, GX1). For further information, refer to Environmental conditions of SIPLUS extreme (on pg. /) or go to Approvals CE, cul CE, cul (available soon) Technical specifications The technical data of the standard product apply with the exception of the environmental conditions. Technical specifications 6AG PB00-BY0 6AG NB10-BA0 6AG MM00-BY1 Supply voltages Rated value 1 V DC No 4 V DC permissible range, lower limit (DC) 10.8 V 0.4 V permissible range, upper limit (DC) 8.8 V 8.8 V Digital inputs Number of digital inputs 4 8 Input voltage for signal "0" for signal "1" Input current for signal "0", max. (permissible quiescent current) for signal "1", typ. Input delay (for rated value of input voltage) < 5 V DC > 1 V DC 1 ma ma for standard inputs - at "0" to "1", max. 1.5 ms - at "1" to "0", max. 1.5 ms Siemens ST 70 N 010 /9
10 Siemens AG 010 SIPLUS expansion modules Technical specifications (continued) Digital outputs Number of digital outputs 4 8; Relay 6AG PB00-BY0 6AG NB10-BA0 6AG MM00-BY1 Short-circuit protection ; electrical (1 A) No; Lamp load, max. Controlling a digital input Parallel switching of outputs for increased power Switching frequency with resistive load, max. with inductive load, max. mechanical, max. Relay outputs Switching capacity of contacts with inductive load, max. with resistive load, max. Thermal continuous current, max. Analog outputs 0,3 A W; 500 W at 115 V AC No Hz 0,5 Hz 10 Hz Number of analg outputs Output ranges, voltage 0 to 10 V EMC Emission of radio interference acc. to EN (limit class B) Degree of protection 3 A 5 A IP0 Standards, approvals, certificates CSA approval developed according to IEC FM approval according to VDE 0631 Marine approval UL approval Mounting spacing units wide 4 spacing units wide Width 36 mm; DU 7 mm; 4 DU 36 mm Height 90 mm 90 mm 90 mm Depth 55 mm 53 mm 55 mm spacing units wide /10 Siemens ST 70 N 010
11 Siemens AG 010 SIPLUS expansion modules Ordering data Order No. Order No. SIPLUS LOGO! DM8 4 Supply voltage 4 V DC, 4x digital inputs 14 V DC, 4x digital outputs 4 V DC, 0.3 A, temperature range C SIPLUS LOGO! DM16 4R Supply voltage 4 V DC, 8x digital inputs 4 V DC, 8x relay outputs 5 A, temperature range C SIPLUS LOGO! AM AQ 4 V DC power supply, x analog inputs V, 0/ ma, 10-bit resolution, temperature range C 6AG PB00-BY0 6AG NB10-BA0 6AG MM00-BY1 Accessories LOGO! manual German English French Spanish Italian Chinese LOGO! memory card for copying, with know-how protection 6ED AA00-0AE7 6ED AA00-0BE7 6ED AA00-0CE7 6ED AA00-0DE7 6ED AA00-0EE7 6ED AA00-0KE7 6ED CA00-0BA0 LOGO!Soft Comfort V6.0 A 6ED BA0-0YA0 For programming on the PC in LAD/FBD; executes on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM LOGO!Soft Comfort V6.0 upgrade Upgrade from V1.0 to V6.0 LOGO! PC cable For program transfer between LOGO! and the PC A 6ED CA0-0YE0 6ED AA00-0BA0 A: Subject to export regulations: AL: N and ECCN: EAR99S Siemens ST 70 N 010 /11
LOGO! logic module. 2/2 Introduction 2/2 LOGO! logic module
Siemens AG 013 / Introduction / /3 /3 basic variants /7 SIPLUS basic variants /9 pure variants /1 SIPLUS pure variants /14 expansion modules /19 SIPLUS expansion modules /3 LOGO! CM EIB/KNX communication
More informationLOGO! logic module. 2/2 Introduction 2/2 LOGO! logic module
Siemens AG 011 / Introduction / /3 /3 basic versions /6 SIPLUS basic versions /8 pure versions /11 SIPLUS pure versions /13 expansion modules /18 SIPLUS expansion modules /1 LOGO! CM EIB/KNX communication
More informationLOGO! logic module. 2/2 Introduction
Siemens AG 008 / Introduction /3 /3 basic versions /6 SIPLUS LOGO! modular basic versions /9 pure versions /1 SIPLUS LOGO! modular pure versions /15 expansion modules /0 SIPLUS LOGO! modules / LOGO! CM
More informationLOGO! Simply different simply ingenious. Micro Automation. Answers for industry.
LOGO! Simply different simply ingenious Micro Automation Answers for industry. Switching and controlling the profitable way Transport facilities Conveyor systems Hoisting platforms Elevators Silo works
More informationLOGO! Simply different simply ingenious. Micro Automation. Answers for industry.
LOGO! Simply different simply ingenious Micro Automation Answers for industry. Switching and controlling the profitable way Transport facilities Conveyor systems Hoisting platforms Elevators Silo facilities
More informationControl Circuit Components LOGO! Logic Module & SITOP Power Supplies
Control Circuit Components LOGO! Logic Module & SITOP Power Supplies Contents Pages LOGO! Programmable Relays Introduction.................................. 15/2 LOGO! Modular Basic Variants LOGO! 24,
More informationLOGO! Now twice as ingenious!
LOGO! Now twice as ingenious! The choice is yours: the well-proven logic module now also with Ethernet Micro Automation siemens.com/logo In infrastructure... Heating / ventilation / air-conditioning Energy
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationLOGO! Logic Modules. General data 7/17. Overview
LOGO! Logic Modules General data Overview The compact, user-friendly, and low-cost solution for simple control tasks Compact, user-friendly, can be used universally without accessories. "All in one": the
More informationSiemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module
Siemens AG 2011 /2 Introduction /4 Central processing units /4 CPU 221 /4 CPU 222 /4 CPU 224 /4 CPU 224 XP, CPU 224 XPsi /4 CPU 226 /24 SIPLUS central processing units /24 SIPLUS CPU 221 /25 SIPLUS CPU
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
More informationFactory Automation SIMATIC LOGO!..0BA6. Colin Limbert. Factory Automation Department. Product Manager LOGO! and S7-200
SIMATIC LOGO!..0BA6 Colin Limbert Department Product Manager LOGO! and S7-200 LOGO!..0BA6 Innovated hardware Overview Innovated inputs LOGO! TD text display 3 new plug-in cards LOGO!..0BA6 Overview LOGO!..0BA6
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationCPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
More informationHMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationT0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
More informationTechnical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
More informationABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
More informationTLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationFrequency Converter Fv
2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationSITOP power supply. Technical data. SITOP Power Supply. Answers for industry.
SITOP power supply Technical data SITOP Power Supply Answers for industry. Selection table SITOP power supplies Input voltage Output current modular smart LOGO!Power Special design, SIMATIC design Others
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationProduct Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301
Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationABB i-bus KNX SA/S Switch Actuators Product Manual
ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationSIMATIC Flat Panel Monitors
Product Data Sheet The Flat Panels are rugged industry-standard LCD monitors. Design of front panels: - 12", 15", 17" and 19" TFT Touch - 12" and 15" TFT Key Installation: - They are equally suited to
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationInput module, input/output module
Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input
More informationSiemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.
The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationkey- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationConnect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.
17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationMeasurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
More informationFREJA 300 Relay Testing System
Relay Testing System A Megger Group Company FREJA 300 Relay testing system The FREJA 300 relay testing system is a computer-aided relay testing and simulation system. The weight of FREJA 300 is only 15
More informationUSB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
More informationPortal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More information3200L 32" Interactive Digital Signage Touch Display
3200L 32" Interactive Digital Signage Touch Display The 3200L Interactive Digital Signage (IDS) display combines precision Elo touch screen technology with a professional-grade, large format LCD panel.
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationW 27-2: The photoelectric switch series with expanded possibilities
W - Photoelectric switches Photoelectric proximity switches, BGS Photoelectric reflex switches Through-beam photoelectric switches W -: The photoelectric switch series with expanded possibilities metres
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationAdding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting
Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters
More information6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A
6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,
More informationSolid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationIndustrial Flat Panel
Product Data Sheet The s are rugged industry-standard LCD monitors in a wide screen design. Installation: - Equally suited for installation in the machine, in control cabinets, in consoles, to gantries,
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationScout 1U Rackmount Computer
Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows
More informationYour automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationReference. 910 402 230 V, 50 Hz A10 415 120 V,60 Hz. 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz. 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz
Rex - analog time switches MicroRex - 3 modules for DIN rail mounting Rex - analog time switches MicroRex - module for DIN rail mounting 926 428 A0 4 MicroRex T3 24 hour program, synchronous motor 92 429
More informationL-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
More informationSINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationRoom Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack
Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationSOUND LEVEL METER 94405
SOUND LEVEL METER 94405 INSTRUCTION MANUAL REC FAST A/C 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified
More informationUSB-AD14f Data Acquisition System (USB)
Data Acquisition System (USB) Measurement & Control. Super-Low Priced. Record and output signals with the USB-AD14f. The USB data acquisition system accomodated in a stable aluminum housing is ideal for
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationInductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
More informationTORKEL 820 Battery Load Unit
TORKEL 820 Lightweight Expandable system Rugged and reliable for field use Test without disconnecting the battery from the equipment it serves Description During a power outage, crucial telecommunication
More informationProgrammable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
More informationO WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications
Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More information