HEATING CONTROLS MAY 2014

Size: px
Start display at page:

Download "HEATING CONTROLS MAY 2014"

Transcription

1 HEATING MAY 2014 YOUR HEATING PARTNER

2 About Us EPH Controls Ltd. is a specialist heating controls company serving both the residential and commercial markets. Formed 17 years ago, EPH began trading as a distributor of heating controls in the Republic of Ireland. In 2010 EPH Controls Ltd began trading operations in both the residential and commercial markets in the UK from a facility in Northamptonshire located at Unit 14, New Barn Farm, Brick Kiln Road, Raunds, Northants NN9 6HY. With an emphasis on supplying quality and innovative products, we now source from within a range of specialist manufacturers. With our technical representatives covering all aspects of heating controls, we are never far away to answer any technical questions you may have. Customer satisfaction is our priority and our aim is to provide a 24 hour delivery service. 1 EPH - YOUR HEATING PARTNER

3 Index Page No Page No Residential Controls DETACH PRO motorised valves Hardwired timeswitches & programmers Mechanical room thermostats Mechanical pipe / cylinder thermostats CURVE digital thermostats Hardwired control packs Wireless enabled timeswitches & programmers CURVE wireless thermostats Wireless packs Wireless control packs Radiator controls Commercial Controls Ball valves & actuators Barberi valves & actuators Renewable controls Solenoid valves & coils Gas detection Gas valves - sales@ephcontrols.co.uk 2

4 Motorised Valves 2 PORT VALVE C/W LIGHT, DETACH BUTTON AND DETACH CABLE V222P V228P 22mm compression, 4.6 Kvs 28mm compression, 6.8 Kvs switch rating: 3 Amps 230Vac max ambient temp: 50 C max fluid temp: 88 C 2 PORT VALVE C/W LIGHT, DETACH BUTTON AND DETACH CABLE V222FP V228FP V232FP 3/4 female BSP, 4.6Kvs 1 female BSP, 6.8Kvs 1 1/4 female BSP, 8.0Kvs switch rating: 3 Amps 230Vac max ambient temp: 50 C max fluid temp: 88 C 3 PORT VALVE C/W LIGHT, DETACH BUTTON AND DETACH CABLE B322P B328P 22mm compression, 4.6 Kvs 28mm compression, 6.8 Kvs max ambient temp: 50 C max fluid temp: 88 C 3 EPH - YOUR HEATING PARTNER

5 REPLACEMENT ACTUATORS FOR 2 PORT VALVES A1P C1P Replacement actuator for EPH Controls V22_ 2 port valve Replacement actuator for Honeywell V40 2 port valve switch rating: 3 Amps 230Vac max ambient temp: 50 C max fluid temp: 88 C REPLACEMENT ACTUATOR FOR 3 PORT VALVES D1P Replacement actuator for EPH Controls B32_P 3 port valve Honeywell V40 3 port valve max ambient temp: 50 C max fluid temp: 88 C CABLE HARNESS ADAPTORS FOR DETACH PRO TO DETACH ACTUATORS CH25 CH26 CH35 Cable harness for 2 port valve with 5 wires Cable harness for 2 port valve with 6 wires Cable harness for 3 port valve with 5 wires - sales@ephcontrols.co.uk 4

6 Hardwired Timeswitches & Programmers New Range 6 pin universal Backplate ONE ZONE TIMESWITCH R17 Switch rating: 3(1)A 230Vac Ambient temp. range C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm 35 x 100 Operating periods per day: 3 Function: 24hr - 5/2 day - 7 day Volt free contacts Frost Protection Keypad lock facility New Range 6 pin universal Backplate TWO ZONE PROGRAMMER HW / CH R27-HW Switch rating: 3(1)A 230Vac Ambient temp. range C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm 35 x 100 Operating periods per day: 3 Function: 24hr - 5/2 day - 7 day 230 Vac contacts only Frost Protection Keypad lock facility ONE ZONE TIMESWITCH T17 Switch rating: 3(1)A 230Vac Ambient temp. range C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm 35 x 100 Operating periods per day: 3 Function: 24hr - 5/2 day - 7 day Volt free contacts Frost Protection 5 EPH - YOUR HEATING PARTNER

7 TWO ZONE PROGRAMMER HW / CH PROGRAMMER T27 T27-HW Switch rating: 3(1)A 230Vac Ambient temp. range C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm 35 x 100 Operating periods per day: 3 Function: 24hr - 5/2 day - 7 day Volt free contacts Frost Protection THREE ZONE PROGRAMMER HW / CH1 / CH2 PROGRAMMER T37 T37-HW Switch rating: 3(1)A 230Vac Ambient temp. range C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm 35 x 100 Operating periods per day: 3 Function: 24hr - 5/2 day - 7 day 230 Vac contacts only Frost Protection FOUR ZONE PROGRAMMER T47 Switch rating: 3(1)A 230Vac Ambient temp. range C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm 35 x 100 Operating periods per day: 3 Function: 24hr - 5/2 day - 7 day 230 Vac contacts only Frost Protection - sales@ephcontrols.co.uk 6

8 Mechanical Room Thermostats New Range COMBI 2 WIRE -Temperature range: Lockable ROOM C/W LIGHT 3 WIRE -Temperature range: Lockable ROOM C/W ON/OFF SWITCH 2 WIRE -Temperature range: Lockable CM2 CM3 CM2S Ideal for Combi Boilers Temperature range: C Switch rating: Volt free contact Switching differential: +/- 1 C IP rating: IP20 Temperature range: Lockable Temperature range: C Switch rating: 230Vac SPDT Switching differential: +/- 1 C IP rating: IP20 Temperature range: Lockable Temperature range: C Switch rating: Volt free contact Switching differential: +/- 1 C IP rating: IP20 Temperature range: Lockable ROOM C/W LIGHT & ON/OFF SWITCH 3 WIRE -Temperature range: Lockable CM3S Temperature range: C Switch rating: 230Vac SPDT Switching differential: +/- 1 C IP rating: IP20 Temperature range: Lockable ROOM FROST C/W LIGHT -Temperature range: Lockable CMF Temperature range: C Switch rating: 230Vac SPST Switching differential: +/- 1 C IP rating: IP20 Temperature range: Lockable TAMPERPROOF ROOM -Temperature range: Lockable CMT Temperature range: C Switch rating: 230Vac SPDT Switching differential: +/- 1 C IP rating: IP20 Internal setpoint adjustable 7 EPH - YOUR HEATING PARTNER

9 EPH Mechanical Pipe / Cylinder Thermostats PIPE / CYLINDER -External setpoint adjustment TAMPERPROOF PIPE / CYLINDER -Internal setpoint adjustment WRP WRP-TP Temperature range: C Switch rating: 230Vac SPDT Switching differential: 5 C IP rating: IP20 IMMERSION -External setpoint adjustment TAMPERPROOF IMMERSION -Internal setpoint adjustment WRP-IM WRP-IM-TP Temperature range: C Switch rating: 230Vac SPDT Switching differential: 5 C IP rating: IP20 SAFETY IMMERSION DUAL WITH MANUAL RESET DBS Temperature range: C High limit temperature: 85 C Switch rating: 230Vac SPDT Switching differential: 5 C IP rating: IP sales@ephcontrols.co.uk 8

10 Digital Thermostats NON PROGRAMMABLE DIGITAL Backlight Keypad Lock Hi & Lo Temp: Limitable Frost protection CDT CDT-24 Mains operated room thermostat 24Vac operated room thermostat Temperature range: C Adjustable switching differential: C Switch rating: 230Vac Contact output: SPDT Volt Free PROGRAMMABLE DIGITAL Backlight Keypad Lock Hi & Lo Temp: Limitable Frost protection CDTP Mains operated room thermostat Temperature range: C Adjustable switching differential: C Switch rating: 230Vac Contact output: SPDT Volt Free NON PROGRAMMABLE DIGITAL Keypad Lock Hi & Lo Temp: Limitable Frost protection CRT Battery operated room thermostat Temperature range: C Adjustable switching differential: C Switch rating: 230Vac Contact output: SPDT Volt Free 9 EPH - YOUR HEATING PARTNER

11 PROGRAMMABLE DIGITAL Keypad Lock Hi & Lo Temp: Limitable Frost protection CRTP Battery operated room thermostat Temperature range: C Adjustable switching differential: C Switch rating: 230Vac Contact output: SPDT Volt Free DIGITAL CYLINDER Keypad Lock CDC Mains operated cylinder thermostat Temperature range: C Adjustable switching differential: C Switch rating: 230Vac Contact output: SPDT Volt Free Cable sensor: NTC 25 C Cable sensor length: 2M WIRING CENTRE WC2 12 Way wiring centre - sales@ephcontrols.co.uk 10

12 Hardwired Control Packs Y PLAN HEATING CONTROL PACK CR22P 1 No R27-HW 2 zone programmer 1 No CM2, room thermostat 1 No WRP, pipe/cylinder thermostat 1 No WC2, 12 way wiring centre 1 No B322P, 22mm 3 port valve S PLAN HEATING CONTROL PACK CR222P 1 No R27-HW 2 zone programmer 1 No CM2, room thermostat 1 No WRP, pipe/cylinder thermostat 1 No WC2, 12 way wiring centre 2 No V222P, 22mm 2 port valves S PLAN UNVENTED HEATING CONTROL PACK CR222PU 1 No R27-HW 2 zone programmer 1 No CM2, room thermostat 1 No WC2, 12 way wiring centre 1 No V222P, 22mm 2 port valve S PLAN HEATING CONTROL PACK CP222P 1 No T27-HW 2 zone programmer 1 No CM2, room thermostat 1 No WRP, pipe/cylinder thermostat 1 No WC2, 12 way wiring centre 2 No V222P, 22mm 2 port valves S PLAN UNVENTED HEATING CONTROL PACK CP222PU 1 No T27-HW 2 zone programmer 1 No CM2, room thermostat 1 No WC2, 12 way wiring centre 1 No V222P, 22mm 2 port valve 11 EPH - YOUR HEATING PARTNER

13 3 ZONE HEATING CONTROL PACK CP322P 1 No T37-HW, 3 zone programmer 2 No CM2, room thermostats 1 No WRP, pipe / cylinder thermostats 1 No WC2, 12 way wiring centre 3 No V222P, 22mm 2 port valves 3 ZONE UNVENTED HEATING CONTROL PACK CP322PU 1 No T37-HW, 3 zone programmer 2 No CM2, room thermostats 1 No WC2, 12 way wiring centre 2 No V222P, 22mm 2 port valves 4 ZONE HEATING CONTROL PACK CP422P 1 No T47, 4 zone programmer 3 No CM2, room thermostats 1 No WRP, pipe / cylinder thermostats 1 No WC2, 12 way wiring centre 4 No V222P, 22mm 2 port valves 4 ZONE UNVENTED HEATING CONTROL PACK CP422PU 1 No T47, zone programmer 3 No CM2, room thermostats 1 No WC2, 12 way wiring centre 3 No V222P, 22mm 2 port valves - sales@ephcontrols.co.uk 12

14 Wireless Enabled Timeswitches & Programmers ONE ZONE ENABLED TIMESWITCH Suitable for use with the following EPH products: TRFi / CRFi / CRFi-230 / VRF1i T17-RFi Switch rating: 3(1)A 230Vac Ambient temp. range: C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm: 35 x 100 Operating periods per day: 3 Function: 24hr - 5/2 day - 7 day Volt free contacts Frost protection TWO ZONE ENABLED PROGRAMMER Suitable for use with the following EPH products: TRFi / CRFi / CRFi-230 / VRF1i T27-RFi Switch rating: 3(1)A 230Vac Ambient temp. range: C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm: 35 x100 Operating periods per day: 3 Function: 24 hr - 5/2 day - 7 day Volt free contacts Frost protection THREE ZONE ENABLED PROGRAMMER Suitable for use with the following EPH products: TRFi / CRFi / CRFi-230 / VRF1i T37-RFi Switch rating: 3(1)A 230Vac Ambient temp. range: C Battery: 3Vdc LIR 2032 Dimensions in mm: 100 x 160 x 30 Screen dimensions in mm: 35 x 100 Operating periods per day: 3 Function: 24 hr - 5/2 day - 7 day 230Vac contacts only Frost protection 13 EPH - YOUR HEATING PARTNER

15 FOUR ZONE ENABLED PROGRAMMER Suitable for use with the following EPH products: TRFi / CRFi / CRFi-230 / VRF1i T47-RFi Switch rating: 3(1)A 230Vac Ambient temp. range: C Battery: 3Vdc LIR 2032 Screen dimensions in mm: 35 x100 Dimensions in mm: 100 x 160 x 30 Operating periods per day: 3 Function: 24 hr - 5/2 day - 7 day 230Vac contacts only Frost protection ONE ZONE RECEIVER Suitable for use with the following EPH products: TRFi / TRFPi / CRFi / CRFi-230 / VRF1i WRS1i Switch rating: 16(3)A 230 Vac Ambient temp. range: C Dimensions in mm: 86 x 86 x 32 Manual override TWO ZONE RECEIVER Suitable for use with the following EPH products: TRFi / TRFPi / CRFi / CRFi-230 / VRF1i WRS2i Switch rating: 16(3)A 230 Vac Ambient temp. range: C Dimensions in mm: 86 x 86 x 32 Manual override - sales@ephcontrols.co.uk 14

16 Wireless Thermostats NON PROGRAMMABLE BATTERY OPERATED Keypad lock Temperature range & limit adjustable Frost protection TRFi Wireless room thermostat Temperature range: C Adustable switching diff: C Batteries included: 2 x AA Alkaline PROGRAMMABLE BATTERY OPERATED Keypad lock Temperature range & limit adjustable Frost protection TRFPi Wireless room thermostat Temperature range: C Adustable switching diff: C Batteries included: 2 x AA Alkaline Programme logic: 5d / 1d / 1d Time periods: 6 periods BATTERY OPERATED CYLINDER Keypad lock CRFi Wireless cylinder thermostat Temperature range: C Adjustable switching diff: C Batteries included: 2 x AA Alkaline Cable sensor: NTC 25 C Cable sensor length: 2M 15 EPH - YOUR HEATING PARTNER

17 MAINS OPERATED CYLINDER Backlight Keypad lock CRFi-230 Wireless cylinder thermostat Temperature range: C Adjustable switching diff: C Supply voltage: 230Vac Cable sensor: NTC 25 C Cable sensor length: 2M CABLE TEMP SENSOR FOR IMMERSION POCKET IMS1 For use with CRFi & CRFi-230 REPEATER RPTR To be used to boost wireless signals in larger applications. TRANSMITTER VRF1i For use with T 7-RFi & WRS1i Can be used to achieve boiler interlock wirelessly - sales@ephcontrols.co.uk 16

18 Wireless Packs ROOM & RECEIVER COMBI PACK 1 1 No TRFi, non programmable wireless room thermostat 1 No WRS1i wireless receiver PROGRAMMABLE ROOM & RECEIVER COMBI PACK 2 1 No TRFPi, programmable wireless room thermostat 1 No WRS1i wireless receiver ONE ZONE CONTROL PACK CWP1i 1 No T17-RFi, 1 zone wireless timeswitch 1 No TRFi, wireless room thermostat 17 EPH - YOUR HEATING PARTNER

19 TWO ZONE CONTROL PACK CWP2i CWP2Ci 1 No T27-RFi, 2 zone wireless programmer 1 No TRFi, wireless room thermostat 1 No CRFi, wireless cylinder thermostat 1 No T27-RFi, 2 zone wireless programmer 1 No TRFi, wireless room thermostat THREE ZONE CONTROL PACK CWP3i CWP3Ci 1 No T37-RFi, 3 zone wireless programmer 2 No TRFi, wireless room thermostats 1 No CRFi, wireless cylinder thermostat 1 No T37-RFi, 3 zone wireless programmer 2 No TRFi, wireless room thermostats FOUR ZONE CONTROL PACK CWP4i CWP4Ci 1 No T47-RFi, 4 zone wireless programmer 3 No TRFi, wireless room thermostats 1 No CRFi, wireless cylinder thermostat 1 No T47-RFi, 4 zone wireless programmer 3 No TRFi, wireless room thermostats - sales@ephcontrols.co.uk 18

20 Wireless Control Packs *Control Packs can be tailor made to suit any application Y PLAN HEATING CONTROL PACK CP22PRF 1 No T27-RFi, 2 zone wireless programmer 1 No TRFi, wireless room thermostat 1 No CRFi, wireless cylinder thermostat 1 No WC2, 12 way wiring centre 1 No B322P, 22mm 3 port valve S PLAN HEATING CONTROL PACK S PLAN UNVENTED HEATING CONTROL PACK CP222PRF CP222PURF 1 No T27-RFi, 2 zone wireless programmer 1 No TRFi, wireless room thermostat 1 No CRFi, wireless cylinder thermostat 1 No WC2, 12 way wiring centre 2 No V222P, 22mm 2 port valves 1 No T27-RFi, 2 zone wireless programmer 1 No TRFi, wireless room thermostat 1 No WC2, 12 way wiring centre 1 No V222P, 22mm 2 port valves 3 ZONE HEATING CONTROL PACK CP322PRF 1 No T37-RFi, 3 zone wireless programmer 2 No TRFi, wireless room thermostats 1 No CRFi, wireless cylinder thermostat 1 No WC2, 12 way wiring centre 3 No V222P, 22mm 2 port valves 19 3 ZONE UNVENTED HEATING CONTROL PACK CP322PURF 1 No T37-RFi, 3 zone wireless programmer 2 No TRFi, wireless room thermostats 1 No WC2, 12 way wiring centre 2 No V222P, 22mm 2 port valves EPH - YOUR HEATING PARTNER

21 *Control Packs can be tailor made to suit any application 4 ZONE HEATING CONTROL PACK CP422PRF 1 No T47-RFi, 4 zone wireless programmer 3 No TRFi, wireless room thermostats 1 No CRFi, wireless cylinder thermostat 1 No WC2, 12 way wiring centre 4 No V222P, 22mm 2 port valves 4 ZONE UNVENTED HEATING CONTROL PACK CP422PURF 1 No T47-RFi, 4 zone wireless programmer 3 No TRFi, wireless room thermostats 1 No WC2, 12 way wiring centre 3 No V222P, 22mm 2 port valves - sales@ephcontrols.co.uk 20

22 Radiator Controls LOCKSHIELD LSV 15mm compression lockshield IC CONTRACT VALVE CTRV 15mm TRV valve body & thermostatic head Max working pressure: 10 Bar Max flow temperature: 110 C Max differential pressure: 1.2 Bar Recommended differential pressure: 0.6 Bar Sensor head temperature range: C EN215 Certified IC RADIATOR VALVE EMTRV 15mm TRV valve & lockshield twin pack Max working pressure: 10 Bar Max flow temperature: 110 C Max differential pressure: 1.2 Bar Recommended differential pressure: 0.6 Bar Sensor head temperature range: C EN215 Certified 21 EPH - YOUR HEATING PARTNER

23 IC RADIATOR VALVE EMTRVBF15 1/2 BSP TRV valve & lockshield twin pack Max working pressure: 10 Bar Max flow temperature: 110 C Max differential pressure: 1.2 Bar Recommended differential pressure 0.6 Bar Sensor head temperature range: C IC RADIATOR VALVE EMTRVBF20 3/4 BSP TRV valve & lockshield twin pack Max working pressure: 10 Bar Max flow temperature: 110 C Max differential pressure: 1.2 Bar Recommended differential pressure: 0.6 Bar Sensor head temperature range: C DRAIN OFF VALVE 10mm REDUCER DOV RED10 15mm x 1/2 BSP drain off valve 10mm brass reducer - sales@ephcontrols.co.uk 22

24 Ball Valves & Actuators 2 PORT FEMALE BALL VALVE S2BV15 S2BV20 S2BV25 S2BV32 S2BV40 S2BV50 DN15, 2 port ballvalve DN20, 2 port ballvalve DN25, 2 port ballvalve DN32, 2 port ballvalve DN40, 2 port ballvalve DN50, 2 port ballvalve BALL VALVE ACTUATOR D10-230S 3pt, 230Vac c/w aux 23 EPH - YOUR HEATING PARTNER

25 EPH Valves & Actuators BRASS 3 PORT SCREWED MIXING VALVE Max pressure: 10 Bar Operating temp: C Leakage rate: <0.1% MA MC ME MG ML MM DN15, 2.5 Kvs with handle DN20, 6.0 Kvs with handle DN25, 12 Kvs with handle DN32, 18 Kvs with handle DN40, 26 Kvs with handle DN50, 40 Kvs with handle BRASS 4 PORT SCREWED MIXING VALVE Max pressure: 10 Bar Operating temp: C Leakage rate: <0.1% MA MC ME MG ML MM DN15, 2.5 Kvs with handle DN20, 6.0 Kvs with handle DN25, 12 Kvs with handle DN32, 18 Kvs with handle DN40, 26 Kvs with handle DN50, 40 Kvs with handle ACTUATORS FOR SCREWED VALVES M DBB M GBB M DBB M GBB M ABB M ABB M MAB 3pt, 60s, 230Vac 3pt, 60s, 230Vac c/w aux 3pt, 60s, 24Vac 3pt, 60s, 24Vac c/w aux 2/3pt, 60s, 230Vac 2/3pt, 60s, 24Vac 0-10Vdc, 60/90/120s, 24Vac - sales@ephcontrols.co.uk 24

26 Valves & Actuators CAST IRON 3 PORT FLANGED MIXING VALVE Max pressure: 6 Bar Operating temp: C P MM P MN P MO P MP P MQ P MR P MS DN40-41 Kvs with handle DN50-65 Kvs with handle DN Kvs with handle DN Kvs with handle DN Kvs with handle DN Kvs with handle DN Kvs with handle 20NM ACTUATORS FOR FLANGED VALVES M FAA M FAA 3pt, 120s, 230Vac c/w aux 3pt, 120s, 24Vac c/w aux LINKAGE KIT P K Linkage kit for M01 actuator ACTUATORS FOR SCREWED VALVES WITH TEMPERATURE COMTROL P T C, 135s, 230V 25 EPH - YOUR HEATING PARTNER

27 EPH Renewable Controls LOAD VALVE FOR SOLID FUEL BOILERS LOAD VALVE FOR SOLID FUEL BOILERS V13M 25 00A V13M 25 00B V13M 25 00C V13M 25 00D V14M 32 00A V14M 32 00B V14M 32 00C V14M 32 00D 1 BSP, 3.2 Kvs, 45 C 1 BSP, 3.2 Kvs, 55 C 1 BSP, 3.2 Kvs, 60 C 1 BSP, 3.2 Kvs, 70 C 1 1/4 BSP, 9.0 Kvs, 45 C 1 1/4 BSP, 9.0 Kvs, 55 C 1 1/4 BSP, 9.0 Kvs, 60 C 1 1/4 BSP, 9.0 Kvs, 70 C LOAD UNIT FOR SOLID FUEL BOILERS Insert one of the following letters at the end of product code for temperature setting selection: A = 45 C B = 55 C C = 60 C D = 70 C 14G X 14G C 14G D 1-1 1/2 BSP without pump 1-1 1/2 BSP with Grundfos UPSO /2 BSP with Grundfos Alpha IC MIXING VALVE FOR USE WITH SOLAR P04A 20 N00L1 P04A 25 N00L2 P05A 20 N00L1 P05A 20 N00L C, 3/4 BSP, 1.8 Kvs C, 1 BSP, 1.8 Kvs C, 3/4 BSP, 2.3 Kvs C, 1 BSP, 2.3 Kvs - sales@ephcontrols.co.uk 26

28 Renewable Controls SOLAR ACCESSORIES 23D Solar pump station controller 04D Bar safety valve, Max temp. 160 C 04D Bar safety valve, Max temp. 160 C 04D Bar safety valve, Max temp. 160 C SOLAR KIT WITH THERMAL INTEGRATION V20M C, 1 BSP, 2.0 Kvs SOLAR PUMP STATION - TROLLINO 05S 0200 AG 16S 0200 BG 3/4 BSP, l/m, Grundfos Solar /4 BSP, l/m, Grundfos Solar SOLAR PUMP 01S 0200 AG STATION - TROLLI 07S 0200 AG 13S 0200 AG 14S 0200 BG 3/4 BSP, l/m, Grundfos Solar /4 BSP, l/m, Grundfos Solar /4 BSP, l/m, Grundfos Solar /4 BSP, l/m, Grundfos Solar SOLAR PUMP STATION WITH BUILT IN CONTROLLER TROLLI PLUS 02S 0200 AG 3/4 BSP, l/m, Grundfos 11S 0200 AG Solar S 0200 BG 1 BSP, l/m, Grundfos 15S 0250 BGM Solar /4 BSP, l/m, Grundfos Solar BSP, l/m, Grundfos Solar EPH - YOUR HEATING PARTNER

29 EPH Solenoid Valves & Coils DIRECT ACTING SOLENOID VALVES NORMALLY CLOSED IP65, C M20D5 M20E7 DN15, 0.6 Kvs, PN25 DN20, 1.0 Kvs, PN25 SUITABLE FOR DIESEL SERVO ASSISTED SOLENOID VALVES NORMALLY CLOSED IP65, C SUITABLE FOR DIESEL M23D13 M23E20 M23F25 M23G35 M23H40 M23I50 DN15, 3.0 Kvs, PN25 DN20, 8.4 Kvs, PN25 DN25, 9.6 Kvs, PN25 DN32, 25.2 Kvs, PN16 DN40, 30.0 Kvs, PN16 DN50, 37.2 Kvs, PN16 SERVO ASSISTED SOLENOID VALVES NORMALLY OPEN IP65, C SUITABLE FOR DIESEL M29D13 M29E20 M29F25 M29G35 M29H40 M29I50 DN15, 3.0 Kvs, PN25 DN20, 8.4 Kvs, PN25 DN25, 9.6 Kvs, PN25 DN32, 25.2 Kvs, PN16 DN40, 30.0 Kvs, PN16 DN50, 37.2 Kvs, PN16 COILS FOR M20 / M23 VALVES IM21F IM21H IM21M IM22 24Vac Vac 230Vac 24Vdc COILS FOR M29 VALVES COIL CONNECTOR IM29F IM29M Vdc 230Vac Connector for coils - sales@ephcontrols.co.uk 28

30 Gas Detection GAS LEAK DETECTORS FOR METHANE AND LPG P11 P12 Methane & Natural gas LPG Gas CARBON MONOXIDE DETECTOR P63 Carbon monoxide detector 4 ZONE GAS LEAK DETECTOR CONTROL UNIT P82 4 zone gas leak detector controller GAS DETECTORS S81 FOR USE WITH P82 CONTROL UNIT S82 ONLY S83 Natural Gas Detector LPG Gas Detector Carbon Monoxide Gas Detector 29 EPH - YOUR HEATING PARTNER

31 EPH Gas Valves GAS VALVE NORMALLY CLOSED AUTO RESET, IP54 ZDEV15 ZDEV20 ZDEV25 ZDEV32 ZDEV40 ZDEV50 ZDEVRF65 ZDEVRF80 ZDEVRF100 DN15, 6.4 Kvs, max p: 500mbar DN20, 14.8 Kvs, max p: 500mbar DN25, 16.7 Kvs, max p: 500mbar DN32, 38.5 Kvs, max p: 500mbar DN40, 47.1 Kvs, max p: 500mbar DN50, 66.7 Kvs, max p: 500mbar DN65, 94.2 Kvs, max p: 500mbar DN80, Kvs, max p: 500mbar DN100, Kvs, max p: 500mbar GAS VALVE NORMALLY CLOSED MANUAL RESET, IP54 ZDEVRM32NC ZDEVRM40NC ZDEVRM50NC ZDEVRMF65NC ZDEVRMF80NC ZDEVRMF100NC DN32, 38.5 Kvs, max p: 500mbar DN40, 47.1 Kvs, max p: 500mbar DN50, 66.7 Kvs, max p: 500mbar DN65, 94.2 Kvs, max p: 360mbar DN80, Kvs, max p: 360mbar DN100, Kvs, max p: 360mbar GAS VALVE NORMALLY OPEN MANUAL RESET, IP54 ZDEVRM32NA ZDEVRM40NA ZDEVRM50NA ZDEVRMF65NA ZDEVRMF80NA ZDEVRMF100NA DN32, 38.5 Kvs, max p: 360mbar DN40, 47.1 Kvs, max p: 360mbar DN50, 66.7 Kvs, max p: 360mbar DN65, 94.2 Kvs, max p: 360mbar DN80, Kvs, max p: 360mbar DN100, Kvs, max p: 360mbar Connections: DN15 - DN50 Valves - Screwed DN65 - DN80 Valves - Flanged - sales@ephcontrols.co.uk 30

32 Mission Statement To provide high quality heating & ventilating products at competitive prices with total customer service at the centre of everything we do. To maintain leadership in our market through innovation, dedication and technical support. Local Stockist EPH EPH Controls Ltd, Unit 14, New Barn Farm, Brick Kiln Road, Raunds, Northants, NN9 6HY Tel: Fax:

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark SET1E Electronic timeswitch for heating & hot water Installation & User Instructions Certification Mark Index INDEX Installation Product specification 3 Installation 4-5 Wiring 5-10 Replacement 11-13 User

More information

evohome Wireless Radiator Zoning Kit Installation & User Guide

evohome Wireless Radiator Zoning Kit Installation & User Guide evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output 133-683 JUNE 28, 2006 TYPE 65UV5-1004 CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output DESCRIPTION APPLICATION The Fireye 65UV5-1004 flame scanner is a microprocessor based flame

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

HCE80/HCC80/HCE80R/HCC80R

HCE80/HCC80/HCE80R/HCC80R HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE. SIT Group 820 NOVA mv MULTIFUNCTIONAL CONTROL FOR GAS THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE PIN 3AP700/2 SINGLE-KNOB MULTIFUNCTIONAL

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

Data sheet Thermostatic sensors type RA 2000

Data sheet Thermostatic sensors type RA 2000 Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and district heating

More information

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments

More information

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

ELECTRIC POSITION for electric heat, then confirm with Fan Test below. Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 1/99 Modutrol Motors Selection Guide This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 2-POSITION SPRING

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN

More information

Wireless 7 Day Programmable Room Thermostat

Wireless 7 Day Programmable Room Thermostat Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable

More information

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors www.static-control.in 1 Introduction The detection or monitoring of flue gases and or hazardous gases has been a complex subject

More information

Installation & User Instructions

Installation & User Instructions 103 electro-mechanical 24 hour timeswitch for controlling hot water and heating Installation & User Instructions including Factory Replacement Units (FRU) Certification Mark This product complies with

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave

More information

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions SET3M electro-mechanical 24 programmer for heating & hot water Installation & User Instructions Index Installation Product specification 3 Installation 4-5 Wiring 6-12 Replacement 13-15 User Your programmer

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats Communicating Thermostats Add More Flexibility to Building Automation with New Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,

More information

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves

More information

Manual for Fire Suppression & Methane Detection System

Manual for Fire Suppression & Methane Detection System Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327

More information

Guidance on how to comply with the 2010 Building Regulations Part L

Guidance on how to comply with the 2010 Building Regulations Part L Guidance on how to comply with the 2010 Building Regulations Part L Version 2.0 10 December 2010 This guide supports the official guidance covering the use of controls in boiler based, gas and oil fired

More information

VC series BALANCED HYDRONIC VALVES 2 -WAY AND 3 -WAY

VC series BALANCED HYDRONIC VALVES 2 -WAY AND 3 -WAY VC series BALANCED HYDRONIC VALVES 2 -WAY AND 3 -WAY APPLICATION PRODUCT HANDBOOK The VC series balanced hydronic valves allow greater control of hot and/or cold water flow. The VC series balanced hydronic

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Manual & Technical Documentation V1.1

Manual & Technical Documentation V1.1 Manual & Technical Documentation V1.1 tado Smart Thermostat tado Extension Kit ENGLISH Content Product Packages Compatibility Intelligence & Security Functions Smart Thermostat Usage Menu Structure Special

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Smile. The All-In-One Heating Controller

Smile. The All-In-One Heating Controller Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from

More information

Frequently Asked Questions

Frequently Asked Questions What is a Thermostatic Radiator Valve? TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler.they should

More information

INSTALLATION & TECHNICAL MANUAL

INSTALLATION & TECHNICAL MANUAL The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk

More information

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES CM927 can be installed without disrupting your room décor as no wiring connection is required between the room unit and the boiler Attractive, slim, ultra-modern

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions MAKING MODERN LIVING POSSIBLE living connect Installation and User Guide Danfoss Heating Solutions 2 living connect Thank you for buying a Danfoss product Danfoss Heating Solutions 3 Contents 1. System

More information

Automatic control equipment for HVAC systems

Automatic control equipment for HVAC systems Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts

More information

Fully Pumped Systems

Fully Pumped Systems Fully Pumped Systems (also see the picture gallery and System Basics) The term for any boiler that uses a pump to move all the heat from the boiler to every part of the system is fully pumped. As a rule

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

Installation Guide for Hive Active Heating

Installation Guide for Hive Active Heating Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during

More information

stainless steel pre-assembled manifolds

stainless steel pre-assembled manifolds TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED Domestic and Non-Domestic Meter Regulators G940/G941 - Domestic Meter Regulator Domestic regulator offering high performance in a compact unit. Sizes:

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT92 WIRELESS DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT92 family of wireless digital room thermostats is a range of market leading products designed to provide comfort with economy

More information

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request. LEAKVALVE: HIGHLIGHTS The core of this valve is a diaphragm in stainless steel 316L, gold plated. Robust, it cannot be damaged with any normal methods. The dead volume is kept as small as possible. There

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss. DOMESTIC HEATING CONTROLS ARE EASY PART 5 - RADIATOR THERMOSTATS Fig.1. RAS-C 2 and RAS-D 2 radiator thermostats with RLV-D lockshield valve Radiator Thermostats (TRVs), the original and straight forward

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines Electronic Throttle Controls for Engines Technical description: Page 2 of 20 The Electronic Throttle Controls have been developed to match the signal required to operate the Modules CM400, CM500 and CM800

More information

VDL 53 - Vacuum drying oven for flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Drayton Digistat +2RF

Drayton Digistat +2RF Drayton Digistat +2RF T Programmable Room Thermostat Wireless 24 Hour Model: RF700/22090 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130

More information

High Output Boiler Systems

High Output Boiler Systems High Output Boiler Systems Information for Dual System Link up methods For use in GB & IE (Great Britain and Republic of Ireland). This appliance has been certified for use in countries other than those

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Certification Mark GB Installation and GB Index Index Installation Instructions 3-14 Product Specification

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

building engineering services association specification for: Domestic Heating www.thebesa.com

building engineering services association specification for: Domestic Heating www.thebesa.com building engineering services association specification for: Domestic central Heating installation www.thebesa.com building engineering services association acknowledgments Guide to good practice: Domestic

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

Direct steam injection humidifiers

Direct steam injection humidifiers Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information