BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp
|
|
- Steven Walker
- 7 years ago
- Views:
Transcription
1 Thermal properties of window frame Type 1 Sheet: 1 Type: Side, top and bottom profile Profile: Frame profile made of wood and a GRP profile mounted with a sealed triple glazing unit. Materials: Wood GRP EPDM λ = 0.13 W/mK λ = 0.30 W/mK λ = 0.25 W/mK Sealed triple glazing ( ) Argon filling h w Dimension [w h] Thermal transmittance of frame Edge construction: Thermal conductivity, 10 mm Thermal conductivity, 1 Bottom 3 mm ψ-value 119 mm 59 mm U f = W/m 2 K λ 10 = 0.21 W/mK λ 14 = 0.42 W/mK λ b = 0.40 W/mK W/mK Calculations performed in accordance with pren
2 Thermal properties of complete window Type 1 Sheet: 2 Type: Whole window Window consists of: Side, Top and Bottom profile Sheet 1 Assumptions: Projected window area mm Sealed triple glazing ( ) Argon filling Side, Top and Bottom profile: Ψ-value U f = W/m²K Ψ = W/mK h f =59 mm U = 0.80 W/m²K Light transmittance τ = 0.43 Net energy gain E ref = 12.6 kwh/m² Calculations performed in accordance with ISO/DIS
3 Window performance when used in an office Type 1 Sheet: 3 Type: Section of two offices. Side walls, roof and floor are all adiabatic surfaces. Construction with high thermal mass ( J/m 2 K). Internal gains: 10 W/m 2. Mechanical balanced ventilation. Ventilation rate: 1.6 times per hour Heat recovery efficiency: 85 % Seasonal Calculation Whole section (STEP 2) Cooling demand 7 kwh/m 2 internal floor area 0 kwh/m 2 internal floor area Hourly Calculation Whole section (STEP3) 26 hours >26 o C Hourly Calculation Office 1 (STEP3) 1.5 kwh/m 2 internal floor area 28 hours >26 o C Hourly Calculation Office 2 (STEP3) 23 hours >26 o C 5 hours >27 o C Calculations performed in WinDesign in accordance with EN ISO
4 Thermal properties of window frame Type 2 Sheet: 4 Type: Side, top and bottom profile Profile: Frame profile made of wood and GRP mounted with a sealed triple glazing unit. Materials: Wood GRP EPDM λ = 0.13 W/mK λ = 0.30 W/mK λ = 0.25 W/mK Sealed triple glazing ( ) Argon filling h Dimension [w h] Thermal transmittance of frame 119 mm 59 mm U f = W/m 2 K w Calculations performed in accordance with pren
5 Thermal properties of complete window Type 2 Sheet: 5 Type: Whole window Window consists of: Side, Top and Bottom profile Sheet 1 Assumptions: Projected window area 1230 x 1480 mm Sealed triple glazing ( ) Argon filling Side, Top and Bottom profile: Ψ-value U f = W/m²K Ψ = W/mK h f =59 mm U = 0.80 W/m²K Light transmittance τ = 0.43 Net energy gain E ref = 3.75 kwh/m² Calculations performed in accordance with ISO/DIS
6 Window performance when used in an office Type 2 Sheet: 6 Type: Section of two offices. Side walls, roof and floor are all adiabatic surfaces. Construction with high thermal mass ( J/m 2 K). Internal gains: 10 W/m 2. Mechanical balanced ventilation. Ventilation rate: 1.6 times per hour Heat recovery efficiency: 85 % Seasonal Calculation Whole section (STEP 2) Cooling demand 7 kwh/m 2 internal floor area 0 kwh/m 2 internal floor area Hourly Calculation Whole section (STEP3) 25 hours >26 o C Hourly Calculation Office 1 (STEP3) 1.5 kwh/m 2 internal floor area 28 hours >26 o C Hourly Calculation Office 2 (STEP3) 22 hours >26 o C 5 hours >27 o C Calculations performed in WinDesign in accordance with EN ISO
Linear thermal transmittance of the assembly of the glazing and the frame in windows
Linear thermal transmittance of the assembly of the glazing and the frame in windows Svend Svendsen,Professor, Technical University of Denmark; ss@byg.dtu.dk; www.byg.dtu.dk Jacob B. Laustsen, Assistant
More informationLow energy class 1 typehouses according to the Danish building regulations
Low energy class 1 typehouses according to the Danish building regulations Jørgen Rose, Senior Researcher, Department of Energy and Environment, Danish Building Research Institute, Aalborg University;
More informationDelivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015
www.zebra2020.eu Delivering on innovation and market uptake. Best-in-cases of nzeb Ramon Pascual Bucharest May 8th, 2015 Outline nzeb Database Best in cases of nzeb Climates in Europe Preliminary results
More informationImproving thermal insulation of concrete sandwich panel buildings
Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general
More informationSistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products
Sistema de Etiquetagem Energética de Produtos (SEEP) Energy Labeling System for Products 10 reasons for an energy labeling system (1/2) The buildings sector is responsible for a considerable share of final
More informationA Parametric study of a metal sandwich VIP. Kjartan Gudmundsson, PhD. dept of Civil and Architectural Engineering. KTH, Stockholm
A Parametric study of a metal sandwich VIP Kjartan Gudmundsson, PhD. dept of Civil and Architectural Engineering. KTH, Stockholm U-value, W/m 2 K outer walls, one family houses Year of construction www.norrlandstrahus.se
More informationGlass partitions SFB 3074
Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use
More informationNorwegian Tax Authority - Oslo Norway
1. INTRODUCTION Norwegian Tax Authority - Oslo Norway PROJECT SUMMARY Year of construction - 1980 No previous energy renovations SPECIAL FEATURES Main topics in the renovation are: High insulated pre fabricated
More informationFABRIC ENERGY EFFICIENCY FOR PART L 2013
Informing the Part L 2013 consultation FABRIC ENERGY EFFICIENCY FOR PART L 2013 WORKED EXAMPLES AND FABRIC SPECIFICATIONS February 2012 Introduction This report has been produced by the Zero Carbon Hub
More informationEcofys VII U-Values for Better Energy Performance of Buildings
Ecofys VII U-Values for Better Energy Performance of Buildings Quantifying the potential I II III IV & V VI Climate Protection Regulation Cost Effectiveness Enlarged EU Price Scenario Key figures from
More informationFACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
More informationANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004
More informationDienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
More informationThe Influence Of Window Type And Orientation On Energy-Saving In Buildings Application To A Single Family Dwelling
The Influence Of Window Type And Orientation On Energy-Saving In Buildings Application To A Single Family Dwelling Urbikain M. K., Mvuama M. C., García Gáfaro C. and Sala Lizarraga J. M. The University
More informationSL30-ISO PROFILE SYSTEM
AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention
More informationTHERMAL LOSSES Thermal Losses Calculations
Calculations -1- THERMAL LOSSES Thermal Losses Calculations Employer : 4M SA Project Location : ASHRAE Office Room : Example from ASHRAE 2013 Handbook - Fundamentals : Chapter 18, Single Room Example Peak
More informationBPC Green Builders. Green building for new and existing homes. Health Comfort Energy
BPC Green Builders Green building for new and existing homes Health Comfort Energy Mechanical Systems Installed HVAC Systems Primary energy source large, roof mounted, solar thermal array (AET flat plate)
More informationBER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric
More informationFederalDemocratic RepublicofEthiopia
FederalDemocratic RepublicofEthiopia EDICTOFGOVERNMENT± Inordertopromotepubliceducationandpublicsafety, equaljusticeforal,abeterinformedcitizenry,therule oflaw,worldtradeandworldpeace,thislegaldocumentis
More informationDiego Ibarra Christoph Reinhart Harvard Graduate School of Design
Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW
More informationENERGY LABELLING OF GLAZINGS AND WINDOWS IN DENMARK: CALCULATED AND MEASURED VALUES
Pergamon P II: S0038 09X(0)00031 Solar Energy Vol. 73, No. 1, pp. 3 31, 00 00 Elsevier Science Ltd All rights reserved. Printed in Great Britain 0038-09X/0/$ - see front matter www.elsevier.com/ locate/
More informationAssessment Methods. 15 th November 2010 Huw Jenkins Simon Lannon
Assessment Methods 15 th November 2010 Huw Jenkins Simon Lannon Assessment Methods Program Country Year Program Country Year 1 R-2000 Canada 1982 12 LEED US 2000 2 P-mark Sweden 1989 13 ECO-Quantum Netherlands
More informationEnergy audit in Finland
Energy audit in Finland NorTech Oulu Lauri Mikkonen Energy Audit in Finland An energy audit tells about the energy efficiency and total energy consumption in a building, including all consumed heating,
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationChallenging the possibilities
Passivhus Norden 2013 Challenging the possibilities Olav Langenkamp, Architect ETH-MAA, Langenkamp.dk Architects, Tigervej 26 8400 Ebeltoft Denmark, ol@langenkamp.dk Martin Wikkelsø Brandt, Cand. Polyt.
More informationKlosterenga, Oslo, Norway, 1998-2000 page - 1
Klosterenga, Oslo, Norway, 1998-2000 page - 1 Introduction Klosterenga is an urban revitalisation project close to the city centre of Oslo. The 3 apartments were built with a focus on energy saving. Next
More informationα α λ α = = λ λ α ψ = = α α α λ λ ψ α = + β = > θ θ β > β β θ θ θ β θ β γ θ β = γ θ > β > γ θ β γ = θ β = θ β = θ β = β θ = β β θ = = = β β θ = + α α α α α = = λ λ λ λ λ λ λ = λ λ α α α α λ ψ + α =
More informationDirectorate for the Built Environment Building Standards Division
Directorate for the Built Environment Building Standards Division Energy Management Solutions Ltd Investigation of measures to improve the energy performance of a existing building: Retail JUNE 2009 Report
More informationSpecification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.
Uniclass L411 +L413:P7114 EPIC D11 +D13:X725 CI/SfB (31.4)+(31.5) Xn6 9/11 SmartSash A BRAND OF THE VEKA UK GROUP Specification Guide Fenestration Solutions for Public Sector & Commercial Applications
More informationConfort 160. Sliding Systems. Sapa Building System
Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic
More informationData Collection Summary Report
Data Collection Summary Report Asilo Cologno Monzese Polo Territoriale per la Prima Infanzia con Asilo Nido 22/09/2011 The sole responsibility for the content of this report lies with the authors. It does
More informationNorwegian Tax Authority - Oslo Norway. Arne Førland-Larsen
Norwegian Tax Authority - Oslo Norway Arne Førland-Larsen Vienna 5 th of September 2012 Magma Center Tenerife foto Torben Eskerod 2 Fredrik Selmers vei 4 sett fra Strømsveien 3 Environmental goals Initially
More informationEnergy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
More information3-D Modeller Rendered Visualisations
Recognised energy Dynamic Simulation Modelling (DSM) software DesignBuilder is a user interface to the EnergyPlus DSM. EnergyPlus builds on the most popular features and capabilities of BLAST and DOE-2
More informationThermal Breakage Prediction
Thermal Breakage Prediction The prediction of glass breakage due to thermal stress is an important analysis for the longevity of a window. Thermal breakage occurs when there is a large temperature differential
More informationSiemens Gebze Location FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD
FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD Slide 1 Energy Efficiency Workshop with KFW & TSKB Sep 28th, 2010 The LEED Green Building Rating System is a voluntary standard that defines high
More informationTHE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel
THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING R.M.J. Bokel Department of Architecture, Delft Technical University, Delft, The Netherlands,
More informationUnbeatable energy efficient glass curtain wall system
Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics
More informationInitial Type Testing Report
Centrum stavebního inženýrství a. s., Praha Centre of Building Construction Engineering, Inc., Prague Accredited Testing Laboratory, Authorised Body, Notified Body, Certification Body workplace Zlín -
More informationCold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
More informationBFRC ENERGY RATING THE REHAU ABC ENERGY EFFICIENT WINDOWS AND DOORS. www.rehau.co.uk. Building Solutions Automotive Industry
BFRC ENERGY RATING THE REHAU ABC ENERGY EFFICIENT WINDOWS AND DOORS www.rehau.co.uk Building Solutions Automotive Industry INTRODUCTION IMPROVING THE ENERGY EFFICIENCY OF WINDOWS AND DOORS This information
More informationThe Warm Edge for insulating glass
The Warm Edge for insulating glass 1. 3. SGGSWISSPACER 2. 4. The best product on the market by quite an edge Energy saving Lower heating costs through better insulation: the thermally improved spacer SGG
More informationInstallation Instructions
Installation Instructions READ BEFORE INSTALLING UNIT For Low Profile Window Air Conditioner INSTALLATION WARNINGS AND CAUTION Carefully read the installation manual before beginning. Follow each step
More informationHigh Specification Windows & Doors
High Specification Windows & Doors Foxrock, Co. Dublin Designed and certified in Denmark Manufactured in Ireland by Carroll Residential External Doors Designed to be secure Certified low U-Value 1.0W/m
More informationA global list. The Fortification Depot A CO 2 -reduction project
The Fortification Depot A CO 2 -reduction project A global list Passive measures: Windows, glazing, solar shading Insulation of walls, roofs, floors Improving air tightness 1 A global list Technical measures:
More informationWINDOWS THE HEAT TRANSFER COEFFICIENT IN DIFFERENT TYPES OF WINDOWS
Part-financed by the European Union (European Regional Development Fund and European Neighbourhood and Partnership Instrument) WINDOWS THE HEAT TRANSFER COEFFICIENT IN DIFFERENT TYPES OF WINDOWS Krzysztof
More informationModule 3.7. Thermal bridging
Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal
More informationMCS 021. HEAT EMITTER GUIDE FOR DOMESTIC HEAT PUMPS Issue 2.0
MCS 021 HEAT EMITTER GUIDE FOR DOMESTIC HEAT PUMPS Issue 2.0 This Guidance is the property of Department of Energy and Climate Change (DECC), 3 Whitehall Place, London,SW1A 2HH. DECC 2014 This guide has
More informationSERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
More informationMulti-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationAIRCONDITIONING Cooling Loads Calculations
Calculations -1- AIRCONDITIONING Cooling s Calculations Employer : 4M SA Project Location : ASHRAE Office Room : Example from ASHRAE 2013 Handbook - Fundamentals : Chapter 18, Single Room Example (p. 18.37)
More informationTest Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
More informationContents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
More informationENERGY EFFICIENCY OPPORTUNITIES IN URBAN REHABILITATION. Maria João Samúdio Agência de Energia do Porto
ENERGY EFFICIENCY OPPORTUNITIES IN URBAN REHABILITATION Maria João Samúdio Agência de Energia do Porto ENERGY FOR FUTURE CITIES Porto 11 04 2011 AdEPorto 2006 - Porto Municipality submitted a joint application
More informationWe have been working in an ideal climate for thirty years.
Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the
More informationAdaptive strategies for office spaces in the UK climate
International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate
More informationEN 1279-5. Insulating glass units, intended to be used in buildings and construction works
4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Argon (90%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics
More informationSAP 2012 IN A NUTSHELL
SAP 2012 IN A NUTSHELL The consultation version of the SAP 2012 methodology was published by the Department of Energy and Climate Change (DECC) on January 4th 2012. This article from Dyfrig Hughes of National
More informationresearch highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
More informationRockwool Cladding Roll
Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F
More informationHEAT TRANSFER ANALYSIS OF COLD STORAGE
HEAT TRANSFER ANALYSIS OF COLD STORAGE Upamanyu Bangale and Samir Deshmukh Department of Mechanical Engineering, SGBA University, Amravati, India ABSTRACT India is largest producer of fruit and vegetable
More informationEFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
More informationCase study on residential building renovation and its impact on the energy use and thermal comfort
Case study on residential building renovation and its impact on the energy use and thermal comfort Hanne Kauko, Maria Justo Alonso, Ole Stavset and Ingrid Camilla Claussen SINTEF Energy Research Motivation
More informationDECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001
NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)
More information24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by
24.301.161 INCORPORATION BY REFERENCE OF INTERNATIONAL ENERGY CONSERVATION CODE (1) The Department of Labor and Industry adopts and incorporates by reference the International Code Council's International
More informationLecture 9, Thermal Notes, 3.054
Lecture 9, Thermal Notes, 3.054 Thermal Properties of Foams Closed cell foams widely used for thermal insulation Only materials with lower conductivity are aerogels (tend to be brittle and weak) and vacuum
More informationiku windows the intelligent self cleaning window AUTOMATIC system
iku windows is a aluminium sliding window system with two rails and double thermal breakage. By adding the iku box underneath the window sill it becomes an intelligent window. Functions Automatic opening
More informationPassiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses Passive Houses are
More informationBUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
More informationResearcH JournaL 2009 / VOL 01.01. www.perkinswill.com
ResearcH JournaL 2009 / VOL 01.01 www.perkinswill.com PERKINS+WILL RESEARCH JOURNAL / VOL 01.01 05. CONTEXT BASED DESIGN OF DOUBLE SKIN FACADES Climatic Considerations During the Design Process Ajla Aksamija,
More informationDow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
More informationDECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001
NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More informationCE66. Windows for new and existing housing
CE66 Windows for new and existing housing Contents Introduction 3 The BFRC Rating 4 Measuring window performance 4 Energy Saving Trust standards 5 General specifications 5 New housing 5 Energy Saving Trust
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationRooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
More informationConservatory Roof Structural Information Guide
Conservatory Roof Structural Information Guide Effective from ugust 8 Useful Information This guide displays data on the permissible roof member spans and for different roof loadings; it should be used
More informationThe BASA Guide to the ISO 11600 Classification of Sealants for Building Construction
The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction SEALANTS IN BUILDING AND CONSTRUCTION Glazing Sealants (G) Construction Sealants (F) Class 25 Class 25LM Class 25 Class
More informationChapter 2: Foundations
Chapter 2: Foundations Crawlspace [V502.1.2] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup under the floor.
More informationENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ
ENERGY STATEMENT for a proposed new residential care home at Great North Road, Doncaster, South Yorkshire, DN6 7EJ Ref. No: 12/02870/FULM Contents 1. General... 2 2. Planning Condition... 2 3. Development...
More informationBuilding Standards Conservatory Roofs Meeting 28 Nov 2012
Conservatory Roofs Meeting 28 Nov 2012 Reason for hosting this meeting Availability of new roofing systems Increasing popularity in changing from transparent to opaque roof finishes Lack of clarity and
More informationGUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.
GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part
More informationPlaisance 24. Sliding Systems. Sapa Building System
Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there
More informationFACADE DESIGN & EXECUTION
Slides are available for public use PROVIDED credit to authors/organisation (M. Berckmoes & P. Lomba / VK Architects & Engineers) is clearly indicated. FACADE DESIGN & EXECUTION I N F O S T E EL - P R
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationSchool in Schwanenstadt, Austria
School in Schwanenstadt, Austria 1. INTRODUCTION PROJECT SUMMARY - building period 1960s - numerous expansions SPECIAL FEATURES - Renovation to meet Passive House Standard - decentralized ventilation system
More informationSCHOTT PYRANOVA Planline System
Schott_050_Pyranova_E_RZ.fh8.07.005 0:50 Uhr Seite HOME T E C H The Planline system The patented glass fixing method is a clear multi- is based on a fire resistant double glazed allows quick and easy replacement
More informationCITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM
CITY PLAN REVIEW AND INSPECTION Lisa Fleming Brown, CPM Houston Commercial Energy Conservation Code (2011) A choice of 2009 IECC or ASHRAE 90.1-2007 with amendments. Effective September 2, 2011. Complete
More informationJimmy Vesterberg. A regression approach for assessment of building energy performance A Licentiate Thesis in Energy Technology
Jimmy A regression approach for assessment of building energy performance A Licentiate Thesis in Energy Technology Motivation Picture: Tomas Mejtoft, 2014. Assessment of building performance First step
More informationDEFECTS IN SHEET ROOFING THAT IMITATES ROOF TILES AS A RESULT OF THEIR ANCHORAGE
2009/3 PAGES 16 23 RECEIVED 31. 3. 2009 ACCEPTED 15. 5. 2009 M. MIHÓK DEFECTS IN SHEET ROOFING THAT IMITATES ROOF TILES AS A RESULT OF THEIR ANCHORAGE Miroslav Mihók Address: Department of Building Construction,
More informationInstallation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:
More informationSENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.
SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION. Waldo Bustamante *1, Felipe Encinas 2 and Francisco Sánchez de la Flor
More informationSAE/ISO Standard for Fire Containment Covers
SAE/ISO Standard for Fire Containment Covers Presented to: International Aircraft Systems Fire Protection Working Group. Long Beach, CA By: Dave Blake, FAA Technical Center Fire Safety Date: The FAA has
More informationReduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U
Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U Applications The High Density Cabinets are suitable for Central Offices and can be used as fiber nodes and termination points
More informationEurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice
Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice A truly international certification The Eurovent Certification Programmes are managed by an autonomous
More informationQuestionnaire Pure Media Systems
1. PROJECT INFORMATION: Project Name: Client: Contact Person: Telephone / Fax N : Email: 2. BASIC INFORMATION Type of Pure Media System PW / HPW - Generation PW / HPW - Storage & Distribution System Cold
More informationPortuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System
Portuguese Certification System for Energy an Indoor Air Quality Statistical Information about the Portuguese Certification System Manuel Casquiço/ ADENE Tabula Expert Workshop - Energy Assessment of National
More informationThe Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study
The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study WARAPORN RATTANONGPHISAT 1,2,*, FEDERICO M. BUTERA 2, R.S. ADHIKARI 2 AND CHALERMPORN YOOPRATETH
More information